Search NASA⌕ Search

SEARCH · Search NASA

Results for “source injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Optical synchrotron radiation beam imaging with a digital mask

The 3GeV SPEAR3 synchrotron light source operates in top-up injection mode with up to 500mA circulating in the storage ring (equivalently 392nC). Each injection pulse contains only 40-80 pC producing a contrast ratio between total stored charge and injected charge of about 6500:1. In order to study transient injected beam dynamics during User operations, it is desirable to optically image the injected pulse in the presence of the bright stored beam. In the present work this is done by re-imaging visible synchrotron radiation onto a digital micro-mirror-array device (DMD), which is then used as an optical mask to block out light from the bright central core of the stored beam. The physical masking, together with an asynchronously-gated, ICCD imaging camera makes it is possible to observe the weak injected beam component on a turn-by-turn basis. The DMD optical masking system works similar to a classical solar coronagraph but has some distinct practical advantages: i.e. rapid adaption to changes in the shape of the stored beam, high extinction ratio for unwanted light and minimum scattering from the primary beam into the secondary optics. In this paper we describe the DMD masking method, features of the high dynamic range point spread function for the SPEAR3 optical beam line and measurements of the injected beam in the presence of the stored beam.

43 PARTICLE ACCELERATORS↗

Results of Multiple Tracer Injections into Fractures in the EGS Collab Testbed-1

The EGS Collab project constructed an intermediate scale (~10-20 m) testbed at the 4850 level of the Stanford Underground Research Facility (SURF) in South Dakota for testing and validating fracture stimulation and flow/transport models. This testbed consists of eight ~200 ft (~60 m) HQ-diameter (9.6 cm) boreholes that are drilled into the crystalline rocks of the Poorman Formation from the West Access Drift tunnel. Of the eight boreholes, one borehole is used as an injection/stimulation well, while another sub-parallel borehole located about 10 m away from the injection well is used as a production well, and rest of the other boreholes are used as geophysical/fluid sampling monitoring wells. Hydraulic stimulation activities were conducted at three locations along the injection hole in an attempt to create direct fracture connections to the production hole. A flow system has been established between injection and production boreholes through a set of hydraulically stimulated fractures propagated from a notch located at 164 ft in the injection hole. Although we planned for a single production well, a set of natural fractures in the testbed is believed to have intersected the stimulated hydraulic fractures and provided additional flow paths for water to be transported to the drift through multiple monitoring boreholes and weep zones. As the flow tests continued after stimulation activities, single or a combination of two or three producers become dominant producers at different times, mostly as a response to intersection of hydraulic fracture and testbed wells, activation of natural fractures and making new leak points to the monitoring wells, resealing of leaky wells, and so on. Since late October 2018, multiple tracers were injected into the fracture system at the 164 ft location that involves both stimulated and natural fractures, and tracers were recovered from multiple locations in nearby wells and weep. The cumulative water recoveries over the time have ranged from 50 to 90%; however, the injected tracer recoveries from various production sources are much less (ranging from a few percentages to 38%). Changes in water/tracer recoveries, shifting of major producing wells from one well to the others, and other observations (e.g., microseismic, electric resistivity tomography, etc.) indicate a testbed that has undergone several changes since October 2018. In this paper, we present tracer recovery data accumulated during several tracer campaigns, provide conceptual testbed flow pathways, and provide observations that suggest a evolutionary nature of fracture volume and fracture geometry in the testbed.

15 GEOTHERMAL ENERGY↗

Microscale device and method for purification of radiopharmaceuticals

A microfluidic chip device for the purification of radiochemical compounds includes a chip having an injection channel and intersecting branch channels with a plurality of valves are located along the injection channel and branch channels and configured to retain a plug of solution containing the radiochemical compound. The chip further includes a serpentine channel segment (for separation) coupled to the output of the injection channel. A high voltage power source advances the plug of solution through the purification region and into the downstream fraction collection channel. The chip includes a downstream fraction collection channel coupled to the serpentine channel segment and having an optical and radiation detection regions. One or more branch fraction channels intersect with the fraction collection channel and include valves located therein so that the radiochemical compound that is detected using a radiation detector is directed into the desired branch fraction channel for subsequent use.

Van Dam, R. Michael↗

Overview on Analyses of Dose Rates During RID Parts Removal/Exchange

One of the most irradiated Spallation Neutron Source (SNS) accelerator components is ring injection dump (RID), which is located downstream of the accumulator ring injection section. The unstripped and only partially stripped H- beam is discarded in the injection into the accumulator ring and is redirected to the RID, which is about 5% of the full beam current. According to the accelerator operation plan, the beam stop and the window assemblies of the existing RID will be removed and replaced, when they have reached their end-of-life. This procedure, which includes multiple steps, is scheduled to take place during facility maintenance period in January 2023.In order to support job planning and meet ALARA requirements during removal and exchange of the components, dose rates for each stage of exchange operation are calculated.

Popova, Irina I.↗

Halide Vapor Phase Epitaxy of Ge from an Elemental Source

Halide vapor phase epitaxy shows promise for low-cost photovoltaic device manufacturing because of its high growth rates and lower cost elemental precursors but previously has not been used to deposit epitaxial Ge. Here, we demonstrate Ge deposition by generating GeCl 2 in situ from solid Ge and HCl in a N 2 ambient. To achieve Ge growth, we inject AsH 3 and PH 3 as sources of active hydrogen to the growth surface to create a driving force for growth. We do not observe Ge growth unless a supply of hydrogen is added, consistent with thermodynamic calculations. Furthermore, we show the hydrogen source must crack readily on the substrate surface to enable growth; relatively stable sources such as H 2 do not cause growth. Unintentional group V doping is one drawback of using AsH 3 and PH 3 to drive the Ge reaction. We observed As or P concentrations in the Ge films ranging from 4 x 10 17 to 1 x 10 18 atoms/cm 3 , concentrations that can drastically influence device characteristics. However, we note there are numerous other "helper molecule" options that can provide active hydrogen without doping or etching the material. This work provides a path forward for Ge deposition for optoelectronic devices from an elemental source.

14 SOLAR ENERGY↗

Spatiotemporal changes of seismic attenuation caused by injected CO 2 at the Frio-II pilot site, Dayton, TX, USA

A continuous active source seismic monitoring data set was collected with crosswell geometry during CO 2 injection at the Frio-II brine pilot, near Liberty, TX. Previous studies have shown that spatiotemporal changes in the P wave first arrival time reveal the movement of the injected CO 2 plume in the storage zone. To further constrain the CO 2 saturation, particularly at higher saturation levels, we investigate spatial-temporal changes in the seismic attenuation of the first arrivals. The attenuation changes over the injection period are estimated by the amount of the centroid frequency shift computed by local time-frequency analysis. We observe that (1) at receivers above the injection zone seismic attenuation does not change in a physical trend; (2) at receivers in the injection zone attenuation sharply increases following injection and peaks at specific points varying with distributed receivers, which is consistent with observations from time delays of first arrivals; then, (3) attenuation decreases over the injection time. The attenuation change exhibits a bell-shaped pattern during CO 2 injection. Under Frio-II field reservoir conditions, White's patchy saturation model can quantitatively explain both the P wave velocity and attenuation response observed. We have combined the velocity and attenuation change data in a crossplot format that is useful for model-data comparison and determining patch size. Our analysis suggests that spatial-temporal attenuation change is not only an indicator of the movement and saturation of CO 2 plumes, even at large saturations, but also can quantitatively constrain CO 2 plume saturation when used jointly with seismic velocity.

58 GEOSCIENCES↗

Studies of beam injection with a compensated bump and uncompensated bump in a synchrotron

Synchrotron radiation sources Indus-1 and Indus-2 have a synchrotron as the common injector. A three kicker compensated bump injection scheme was employed for beam injection into this synchrotron. The stored beam current in the synchrotron is higher, when all the three kickers are operated at the same current than when kickers are operated at currents required to generate compensated bump. Beam dynamics studies have been done to understand why this happens. Theoretical studies indicate that higher stored current in the later case is attributed to smaller residual oscillations of injected beam. These studies also reveal that if the angle of the injected beam during beam injection is kept varying, the performance could be further improved. This is experimentally confirmed by injecting the beam on rising part of the injection septum magnet current pulse.

43 PARTICLE ACCELERATORS↗

Impact of transparent electrode on photoresponse of ZnO-based phototransistor

ZnO-based photo-thin film transistors with enhanced photoresponse were developed using transparent conductive oxide contacts. Changing the electrode from opaque Mo to transparent In-Zn-O increases the photocurrent by five orders of magnitude. By changing the opacity of each source and drain electrode, we could observe how the photoresponse is affected. We deduce that the photocurrent generation mechanism is based on an energy band change due to the photon irradiation. More importantly, we reveal that the photocurrent is determined by the energy barrier of injected electrons at the interface between the source electrode and the active layer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Two-stage Injection-locked Magnetron for Accelerators with Superconducting Cavities

A concept for a two-stage injection-locked CW magnetron intended to drive Superconducting Cavities (SC) for intensity-frontier accelerators has been proposed. The concept considers two magnetrons in which the output power differs by 15-20 dB and the lower power magnetron being frequency-locked from an external source locks the higher power magnetron. The injection-locked two-stage CW magnetron can be used as an RF power source for Fermilab's Project-X to feed separately each of the 1.3 GHz SC of the 8 GeV pulsed linac. We expect output/locking power ratio of about 30-40 dB assuming operation in a pulsed mode with pulse duration of ~ 8 ms and repetition rate of 10 Hz. The experimental setup of a two-stage magnetron utilising CW, S-band, 1 kW tubes operating at pulse duration of 1-10 ms, and the obtained results are presented and discussed in this paper.

43 PARTICLE ACCELERATORS↗

Basic Research on the Composition of Heavy Cosmic Rays: The Trans-Iron Galactic Element Recorder Experiment (TIGER)

Among the most fundamental astrophysical problems is understanding the mechanism by which particles are accelerated to the enormous energies observed in the cosmic rays. That problem can be conveniently divided into two questions: (1) What is the source of the energy and the mechanism for converting the energy of that source into the energy of individual cosmic-ray nuclei, and (2) what is the source of the material that is accelerated and the mechanism for injecting that material into the cosmic-ray accelerator? There is a general consensus that the answer to the first of these questions, for nuclei with energy eV, is that the source of their energy is almost certainly from supernova explosions (e.g., Ginzburg & Syrovatskii, 1964). The answer to the second question is still uncertain, although evidence in favor of a superbubble origin of cosmic rays is becoming quite significant (Higdon et al, 2203 and Binns, 2005 (Submitted to ApJ). There are several ways of interpreting available data that lead to quite different models for the source of the material and its injection mechanism. With the The Trans-Iron Galactic Element Recorder Experiment (TIGER) instrument we have obtained data that will help to distinguish among these possible models. In the report, the TIGER flights, the instrument itself, results, and a publication list as a result of the work are presented.

Binns, W. Robert↗

Evaluation of Flow-Injection Tandem Mass Spectrometry for Rapid and High-Throughput Quantitative Determination of B-Vitamins in Nutritional Supplements

The use of flow-injection electrospray ionization tandem mass spectrometry for rapid and high-throughput mass spectral analysis of selected B-vitamins, viz. B1, B2, B3, B5, and B6, in nutritional formulations was demonstrated. A simple and rapid (~5 min) in-tube sample preparation was performed by adding extraction solvent to a powdered sample aliquot followed by agitation, centrifugation, and filtration to recover an extract for analysis. Automated flow injection introduced 1 L of the extracts directly into the mass spectrometer ion source without chromatographic separation. Sample-to-sample analysis time was 60 s representing significant improvement over conventional liquid chromatography approaches which typically require 25-45 min, and often require more significant sample preparation procedures. Quantitative capabilities of the flow-injection analysis were tested using the method of standard additions and NIST standard reference material (SRM 3280) multivitamin/multielement tablets. The quantity determined for each B-vitamin in SRM 3280 was within the statistical range provided for the respective certified values. The same sample preparation and analysis approach was also applied to two different commercial vitamin supplement tablets and proved to be successful in the quantification of the selected B-vitamins as evidenced by an agreement with the labels values and the results obtained using isotope dilution liquid chromatography/mass spectrometry.

59 BASIC BIOLOGICAL SCIENCES↗

Laser and optical system for laser assisted hydrogen ion beam stripping at SNS

A high-efficiency laser assisted hydrogen ion (H-) beam stripping was recently successfully carried out in the Spallation Neutron Source (SNS) accelerator. The experiment was not only an important step toward foil-less H- stripping for charge exchange injection, it also set up a first example of using megawatt ultraviolet (UV) laser source in an operational high power proton accelerator facility. This study reports in detail the design, installation, and commissioning result of a macro-pulsed multi-megawatt UV laser system and laser beam transport line for the laser stripping experiment.

43 PARTICLE ACCELERATORS↗

Theory of plasma contractors for electrodynamic tethered satellite systems

Recent data from ground and space experiments indicate that plasma releases from an object dramatically reduce the sheath impedance between the object and the ambient plasma surrounding it. Available data is in qualitative accord with the theory developed to quantify the flow of current in the sheath. Electron transport in the theory is based on a fluid model of a collisionless plasma with an effective collision frequency comparable to frequencies of plasma oscillations. The theory leads to low effective impedances varying inversely with the square root of the injected plasma density. To support such a low impedance mode of operation using an argon plasma source for example requires that only one argon ion be injected for each thirty electrons extracted from the ambient plasma. The required plasma flow rates are quite low; to extract one ampere of electron current requires a mass flow rate of about one gram of argon per day.

Parks, D. E.↗

Theory of plasma contactors for electrodynamic tethered satellite systems

Recent data from ground and space experiments indicate that plasma releases from an object dramatically reduce the sheath impedance between the object and the ambient plasma surrounding it. Available data is in qualitative accord with the theory developed to quantify the flow of current in the sheath. Electron transport in the theory is based on a fluid model of a collisionless plasma with an effective collision frequency comparable to frequencies of plasma oscillations. The theory leads to low effective impedances varying inversely with the square root of the injected plasma density. To support such a low impedance mode of operation using an argon plasma source, for example, requires that only one argon ion be injected for each thirty electrons extracted from the ambient plasma. The required plasma flow rates are quite low; to extract one ampere of electron current requires a mass flow rate of about one gram of argon per day.

Parks, D. E.↗

Ultra-lean combustion at high inlet temperatures

Combustion at inlet-air temperatures of 1100 to 1250 K was studied for application to advanced automotive gas turbine engines. Combustion was initiated by the hot environment, and therefore no external ignition source was used. Combustion was stabilized without a flameholder. The tests were performed in a 12-cm-diameter test section at a pressure of 250,000 Pa, with reference velocities of 32 to 60 m/s and at maximum combustion temperatures of 1350 to 1850 K. Number 2 diesel fuel was injected by means of a multiple-source fuel injector. Unburned hydrocarbon emissions were negligible for all test conditions. Nitrogen oxide emissions were less than 1.9 g NO2/kg fuel for combustion temperatures below 1680 K. Carbon monoxide emissions were less than 16 g CO/kg fuel for combustion temperatures greater than 1600 K, inlet-air temperatures higher than 1150 K, and residence times greater than 4.3 ms.

Anderson, D. N.↗

GADRAS Batch Inject Tool User Guide

Gamma Detector Response and Analysis Software (GADRAS) is used by the radiation detection and emergency response community to perform modeling and spectral analysis for gamma detector systems. Built into GADRAS is the ability to define a detector, geometry, background characteristics and source composition to generate synthetic spectra for drills and exercises (injects). Consequence Management is currently in development of a sample result data simulator tool in which a deposition model is probed for source conditions at moments in time and locations in space. These values are used to generate realistic sample results for use in drills and exercises. In addition to sample results, there is a need to simulate the actual spectra that would be observed in the field by downlooking HPGe instruments given a deposition activity. This way, the FRMAC Gamma Spectroscopist can practice their process of generating quantified results from spectra on realistic data as well. Recognizing the decades of work done in GADRAS to accurately generate synthetic spectra, this team decided to build a link between the new simulator and GADRAS to generate these spectra quickly and easily. The simulator tool will generate a file that specifies the name of the spectra, its location, date/time of measurement, duration of measurement, height off the ground, and the deposition activity and age for every radionuclide in the simulation. Then, a new tool within the Inject Tab of GADRAS was developed to read in this file given a detector selection and generate In-Situ spectra for each row in the file in any file format the user chooses. This way, simulation cell staff can take these files and then upload them to the appropriate data system (RAMS or RadResponder) for use during drills and exercises. An advanced feature of this tool allows for generating any spectra given an appropriate model and mapping of source to model layer in the batch inject tool. This way, spectra from field sample counts, mobile laboratories, or even fixed laboratories can be generated in bulk given an estimate of the radioactivity concentration or total radioactivity in an import file. This expands the capabilities of this tool a great deal and will make it a more useful tool for CM and others to help estimate detector response for nearly any situation. This user guide will explain the steps needed to perform a batch inject file generation.

61 RADIATION PROTECTION AND DOSIMETRY↗

CONSTRAINTS ON THE GALACTIC HALO DARK MATTER FROM FERMI-LAT DIFFUSE MEASUREMENTS

We have performed an analysis of the diffuse gamma-ray emission with the Fermi Large Area Telescope (LAT) in the Milky Way halo region, searching for a signal from dark matter annihilation or decay. In the absence of a robust dark matter signal, constraints are presented. We consider both gamma rays produced directly in the dark matter annihilation/decay and produced by inverse Compton scattering of the e {sup +}/e {sup -} produced in the annihilation/decay. Conservative limits are derived requiring that the dark matter signal does not exceed the observed diffuse gamma-ray emission. A second set of more stringent limits is derived based on modeling the foreground astrophysical diffuse emission using the GALPROP code. Uncertainties in the height of the diffusive cosmic-ray halo, the distribution of the cosmic-ray sources in the Galaxy, the index of the injection cosmic-ray electron spectrum, and the column density of the interstellar gas are taken into account using a profile likelihood formalism, while the parameters governing the cosmic-ray propagation have been derived from fits to local cosmic-ray data. The resulting limits impact the range of particle masses over which dark matter thermal production in the early universe is possible, and challenge the interpretation of the PAMELA/Fermi-LAT cosmic ray anomalies as the annihilation of dark matter.

79 ASTRONOMY AND ASTROPHYSICS↗