Search NASA⌕ Search

SEARCH · Search NASA

Results for “spaceflight response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Small Particle Response to Fluid Motion using Tethered Particles to Simulate Microgravity

This paper reports on ground based work conducted to support the Spaceflight Definition project SHIVA (Spaceflight Holography Investigation in a Virtual Apparatus). SHIVA will advance our understanding of the movement of a particle in a fluid. Gravity usually dominates the equations of motion, but in microgravity as well as on earth other terms can become important. Before two members of our team found an analytical solution of the equations, numerical methods and/or neglecting terms were required. The general solution predicts that the usually neglected history term becomes important when the characteristic viscous time is in the same order as the vibration period and peaks when the two times are equal. In this case three force terms, the Stokes drag, the added mass, and the history drag must all be included in predicting particle movement. We also developed diagnostic recording methods using holography to save all of the particle field data, allowing the experiment to essentially be transferred from space back to earth in what we call the "virtual apparatus". Using state-of-the-art methods in holography we will quantify the three-dimensional motion of sets of particles, allowing us to test and apply the new analytical solutions. The motion of particles up to 4 mm in diameter in a fluid that oscillates at frequencies up to 100 Hz with amplitudes up to 200 microns is being examined. Ground studies to support the flight development program have employed various schemes to simulate microgravity. One of the most reliable and meaningful methods uses spheres tethered to a fine hair suspended in the fluid. We have also investigated particles with nearly neutral buoyancy. Recordings are made at the peak amplitudes of vibration of the cell providing a measure of the ratio of fluid to particle amplitude. The experiment requires precise location of the particle at the time of recording. The hologram of the particle provides microscopic images of the particle that are used for finding the position with an accuracy of a few microns. To make the experiment more versatile, the spaceflight system will record holograms both on film and electronically. The electronic holograms can be downlinked providing real time data. Results of the ground experiments, the flight experiment design, and data analysis procedures are reported.

Trolinger, J. D.↗

Small Particle Response to Fluid Motion using Tethered Particles to Simulate Microgravity

This paper reports on ground based work conducted to support the Spaceflight Definition project SHIVA (Spaceflight Holography Investigation in a Virtual Apparatus). SHIVA will advance our understanding of the movement of a particle in a fluid. Gravity usually dominates the equations of motion, but in microgravity as well as on earth other terms can become important. Before two members of our team found an analytical solution of the equations, numerical methods and/or neglecting terms were required. The general solution predicts that the usually neglected history term becomes important when the characteristic viscous time is in the same order as the vibration period and peaks when the two times are equal. In this case three force terms, the Stokes drag, the added mass, and the history drag must all be included in predicting particle movement. We also developed diagnostic recording methods using holography to save all of the particle field data, allowing the experiment to essentially be transferred from space back to earth in what we call the "virtual apparatus". Using state-of-the-art methods in holography we will quantify the three-dimensional motion of sets of particles, allowing us to test and apply the new analytical solutions. The motion of particles up to 4 mm in diameter in a fluid that oscillates at frequencies up to 100 Hz with amplitudes up to 200 microns is being examined. Ground studies to support the flight development program have employed various schemes to simulate microgravity. One of the most reliable and meaningful methods uses spheres tethered to a fine hair suspended in the fluid. We have also investigated particles with nearly neutral buoyancy. Recordings are made at the peak amplitudes of vibration of the cell providing a measure of the ratio of fluid to particle amplitude. The experiment requires precise location of the particle at the time of recording. The hologram of the particle provides microscopic images of the particle that are used for finding the position with an accuracy of a few microns. To make the experiment more versatile, the spaceflight system will record holograms both on film and electronically. The electronic holograms can be downlinked providing real time data. Results of the ground experiments, the flight experiment design, and data analysis procedures are reported.

Trolinger, J. D.↗

Phototropic Response of Microgreens in Simulated Microgravity

Microgreens are a class of nutritionally-dense young crop plants which show promise for spaceflight applications. This study investigated the germination and subsequent growth of mustard microgreens in simulated microgravity, under different lighting conditions. Images of seedling growth and the specialized hardware that was developed for this project, along with relevant protocols and lessons learned, are provided in this technical report.

space crop production; microgreen; microgravity si↗

Comparison of Active and Passive Head Impulse Testing of the Horizontal Vestibulo-Ocular Reflex: Exploring the Feasibility of Different Approaches for Spaceflight

INTRODUCTION: Astronauts experience a wide variety of sensorimotor disturbances primarily due to microgravity-induced vestibular adaptations during spaceflight. Head Impulse Testing (HIT) will be conducted during the Complement of Integrated Protocols for Human Exploration Research program(CIPHER) Vestibular Health study to examine changes in the horizontal vestibulo-ocular reflex in response to high-velocity head movements to detect changes in peripheral vestibular function [1,2]. However, correct interpretation will require consideration of potential artifacts and the constraints of conducting this test across different phases of the mission. Therefore, the aims of our study were to (1) examine reliability across different test operators, and (2) compare results of active (aHIT) versus passive (pHIT) approaches to evaluate the feasibility of self-administered versus operator-assisted approaches. A comparison of responses with visual viewing of a wall target (default condition) versus vision occluded evaluated the influence of other oculomotor control influence across conditions, and comparison with computer-generated rotator head impulse tests (rHIT) examined the variability associated with the ocular responses independent of the variability in executing the head movements themselves. METHODS: Seventeen non-astronaut volunteers (male n=12, age=22.9 ± 3.0; female n=5, age=27.0 ± 6.0, mean ± std) completed HIT testing using video-oculography (VOG) goggles and a high-torque rotator system. The test order was counterbalanced across conditions: (1) passive head-on-torso (pHIT, default condition for flight study) using two operators (Op1 and Op2), (2) active head-on-torso (aHIT, subject initiated), and (3) passive head and torso using rotary chair (rHIT). Eye and head movement data were processed to obtain gain in each direction. The main outcome measures were average gain and asymmetry [1], as well as the percentage of acceptable trials not excluded due to insufficient head amplitude or recording artifacts. RESULTS: While the pHIT gains were similar with vision (1.032 ± 0.043) and vision occluded (1.029 ± 0.038) conditions, the percentage of acceptable trials was greater with vision (Op1 = 93.0%, Op2 = 93.2%) versus occluded (Op1 = 70.7%, Op2 = 67.6%). The reliability between operators was greater for pHIT gain (Intraclass Correlation, ICC = 0.66, p = 0.001) than for pHIT asymmetry (ICC = 0.57, p = 0.01). The percentage of acceptable trials reduced by ~20% during the self-administered aHITs for both visual conditions and tended to be lower than computer-generated rHITs (76% versus 83%). While the aHIT gains were not significantly different than pHIT gains for vision or vision occluded conditions, these measures were poorly correlated. Both aHIT and pHIT gains were significantly greater than the rHIT gains, presumably due to the reduced velocities from the rotator. The asymmetry measures were poorly correlated across pHIT, aHIT, and rHIT conditions, although none of the subjects had asymmetries greater than 16%. DISCUSSION: Our findings support the feasibility of using the standard pHIT methodology for spaceflight. Similarities between visual conditions reflect that these responses are mediated by the peripheral lateral canals rather than other oculomotor mechanisms. The inter-tester reliability was acceptable despite differences in the tester training. In addition to concerns of non-vestibular mechanisms introduced during self-administered aHITs [2], operator-assisted pHITs resulted in higher percentage of acceptable trials and should result in more efficient and reliable measures during spaceflight.

M R Ehrenburg↗

Plasticity of Neurovestibular Systems Following Micro- and Hyper-Gravity Exposure and Readaptation to Earth's 1G

The gravity-sensing organs sense the sum of inertial force due to head translation and head orientation relative to gravity. Normally gravity is constant, and yet the neural sensors show remarkable plasticity. When the force of gravity changes, such as in spaceflight or during centrifugation, the neurovestibular system responds by regulating its neural output, and this response is similar for the vertebrate utricular nerve afferents and for the statocyst hair cell in invertebrates. First, we examine the response of utricular afferents in toadfish following exposure to G on two orbital missions (STS-90 and 95). Within the first day after landing, magnitude of neural response to an applied acceleration was significantly elevated, and re-adaptation back to control values occurred within approximately 30 hours. Time course of return to normal approximately parallels the decrease in vestibular disorientation in astronauts following return. Next, we use well-controlled hyper-G experiments in the vertebrate model to address: If G leads to adaptation and subsequent re-adaptation neural processes, does the transfer from 1G to hyper-G impart the opposite effects and do the effects accompanying transfer from the hyper-G back to the 1G conditions resemble as an analog the transfer from 1G to the microG Results show a biphasic pattern in reaction to 3G exposures: an initial sensitivity up-regulation (3- and 4-day) followed by a significant decrease after longer exposure. Return to control values is on the order of 4-8 days. Utricular sensitivity is strongly regulated up or down by gravity load and the duration of exposure. Interestingly, we found no correlation of response and hair cell synaptic body counts despite the large gain difference between 4- and 16-Day subjects. Lastly, we examine responses of statocyst receptors in land snail following exposure to G on two unmanned Russian Orbital missions (Foton M-2 and -3). Here, we have the ability to measure the output directly from the hair cells. Similar to afferents in vertebrates the hair cells increased their response sensitivity to vestibular stimulation. Two major pieces of information are needed: the precise vertebrate hair cell response to altered gravity and the impact of longer duration exposures on sensory plasticity.

Boyle, Richard D.↗

NASA FACTS: E. coli AntiMicrobial Satellite (EcAMSat)

The E. coli AntiMicrobial Satellite(EcAMSat) mission will investigate space microgravity affects on the antibiotic resistance of E. coli, a bacterial pathogen responsible for urinary tract infection in humans and animals. EcAMSat is being developed through a partnership between NASAs Ames Research Center and the Stanford University School of Medicine. Dr. A.C. Matin is the Stanford University Principal Investigator. EcAMSat will investigate spaceflight effects on bacterial antibiotic resistance and its genetic basis. Bacterial antibiotic resistance may pose a danger to astronauts in microgravity, where the immune response is weakened. Scientists believe that the results of this experiment could help design effective countermeasures to protect astronauts health during long duration human space missions.

Spremo, Stevan↗

Evaluation of Human Spaceflight-Related Tissue Weight Relief Using Whole Body Finite Element Model Simulations

Tissue Weight Relief (TWR) is a physiological condition observed in human spaceflight. It not only impacts the injury biomechanics of soft tissue but also the physiological responses of the cardiovascular system both due to fluid redistribution and the effect of tissue-related transmural pressure on the large venous blood vessels. Understanding the effects of tissue weight relief is especially important because of the role it may play in understanding the cause of Space Associated Neuro-Ocular Syndrome (SANS). SANS can be characterized by a number of ocular changes which reduce visual acuity and SANS related symptoms occur in up to 51% of astronauts. A prevailing theory for the causation of SANS is that of headward (cephalad) fluid shift and a prolonged increase of Intracranial Pressure (ICP) similar to intracranial hypertension, which is not fully supported by the experimental data or astronaut symptom reporting. However, it is still believed that SANS is caused by a pressure change in the eye and the surrounding tissues. It has been proposed that TWR plays a substantial role in affecting internal pressures and fluid shifts in microgravity. In this effort, two whole-body Finite Element (FE) models – Elemance and THUMS – are used to ascertain the microgravity-associated TWR of the musculature surrounding the lower body veins. Elemance and THUMS are physics-based computational models that have been validated and verified for several automotive and domestic applications, and as such, can simulate the relief of soft tissue weight due to changes in the gravitation vector. Specifically, the current effort modeled the transition of the gravitational vector from 1G to 0G, applied across the whole-body model in a supine position. For each 1G to 0G transition simulation, the lower body vein’s transmural pressure-time profile was extracted and averaged around the anterior portion of the thigh muscle. The ascertained transmural pressure changes from 1G to 0G transition are given in Figure 1 for the Elemance and the THUMS FE models. The transmural pressure changes of 10 mmHg and 21 mmHg are in the same order of magnitude as Lu’s value of 44 mmHg. It is to be noted that Lu implemented a 0D to 1D lumped parameter model and the Elemance and THUMS are 3D higher order computational models. This proof-of-concept approach demonstrates that TWR pressure can be adequately estimated with in silico techniques however, further in silico investigations need to be conducted to address the unique contributions to the transmural pressure from each of the computational models.

Finite element modeling↗

DEVELOPMENT OF AN INFLIGHT COUNTERMEASURE TO MITIGATE POSTFLIGHT GAIT DYSFUNCTION

Following spaceflight crewmembers experience gait and postural instabilities due to inflight adaptive alterations in sensorimotor function. These changes can pose a risk to crew safety if nominal or emergency vehicle egress is required immediately following long-duration spaceflight. At present, no operational countermeasure is available to mitigate postflight locomotor disturbances. Therefore, the goal of this study is to develop an inflight training regimen that facilitates the recovery of locomotor function after long-duration spaceflight. The countermeasure we are developing is based on the concept of variable practice. During this type of training the subject gains experience producing the appropriate adaptive motor behavior under a variety of sensory conditions and response constraints. This countermeasure is built around current ISS treadmill exercise activities. Crewmembers will conduct their nominal inflight treadmill exercise while being exposed to variations in visual flow patterns. These variations will challenge the postural and locomotor systems repeatedly, thereby promoting adaptive reorganization in locomotor behavior. As a result of this training a subject learns to solve a class of motor problems, rather than a specific motor solution to one problem, Le., the subject learns response generalizability or the ability to "learn to learn" under a variety of environmental constraints. We anticipate that this training will accelerate recovery of postural and locomotor function during readaptation to gravitational environments following spaceflight facilitating neural adaptation to unit (Earth) and partial (Mars) gravity after long-duration spaceflight. The study calls for one group of subjects to perform the inflight treadmill training regimen while a control group of subjects performs only the nominal exercise procedures. Locomotor function in both groups is assessed before and after spaceflight using two tests of gait function: The Integrated Treadmill Locomotion Test (ITLT) and the Functional Mobility Test (FMT). The ITLT characterizes alterations in the integrated function of multiple sensorimotor subsystems responsible for the control of locomotion. This test calls for subjects to walk on a motorized treadmill while we assess changes in dynamic postural stability, head-trunk coordination, short-latency head stabilization responses, dynamic visual acuity, lower limb coordination strategies and gait cycle timing. To make these assessments we measure the following parameters while subjects walk on the treadmill: 1) full body 3-dimensional kinematics using a motion capture system (Motion Analysis Corp., Santa Rosa, CA); 2) the shock-wave transmitted from heel-strike to the head using triaxial accelerometers placed on the tibia and head (Entran, Fairfield, NJ); 3) vertical forces using an instrumented treadmill (Kistler Instrument Corp., Amherst, NY); 4) Dynamic visual acuity using Landolt Cs presented on a laptop computer located 4m from the eyes and 5) Gait cycle timing using foot-switches (Motion Lab Systems, Inc., Baton Rouge, LA) attached to the plantar surface of each shoe at the heel and toe. The FMT evaluates a subject's ability to perform challenging locomotor maneuvers similar to those encountered during an egress from a space vehicle. Subjects step over and duck under obstacles along with negotiating a series of pylons set up on a base of 10 cm thick medium density foam. The dependent measures for the FMT are time to complete the course and the number of obstacles touched. To date, we have collected pre and postflight locomotion data from Expeditions 5-9 who will serve as part of the control group for this study. Preliminary results comparing the recovery rates in gait control sub-systems obtained from the ITLT and FMT performance showed two recovery patterns: 1) a concordant recovery trend between gait control parameters and FMT performance indicating a restitution pattern of recovery and 2) gait controecovery that lagged recovery in FMT performance suggesting that improvement in locomotor function was attained through a pattern of substitution. These data suggest that recovery of postflight locomotor function may occur through adaptive mechanisms that lead to either restitution or substitution of function. Understanding the modes of postflight readaptation has implications for countermeasure development and testing and in astronaut postflight rehabilitation.

Bloomberg, J. J.↗

Development of an Inflight Countermeasure to Mitigate Postflight Gait Dysfunction

Following spaceflight crewmembers experience gait and postural instabilities due to inflight adaptive alterations in sensorimotor function. These changes can pose a risk to crew safety if nominal or emergency vehicle egress is required immediately following long-duration spaceflight. At present, no operational countermeasure is available to mitigate postflight locomotor disturbances. Therefore, the goal of this study is to develop an inflight training regimen that facilitates the recovery of locomotor function after long-duration spaceflight. The countermeasure we are developing is based on the concept of variable practice. During this type of training the subject gains experience producing the appropriate adaptive motor behavior under a variety of sensory conditions and response constraints. This countermeasure is built around current ISS treadmill exercise activities. Crewmembers will conduct their nominal inflight treadmill exercise while being exposed to variations in visual flow patterns. These variations will challenge the postural and locomotor systems repeatedly, thereby promoting adaptive reorganization in locomotor behavior. As a result of this training a subject learns to solve a class of motor problems, rather than a specific motor solution to one problem, Le., the subject learns response generalizability or the ability to "learn to learn" under a variety of environmental constraints. We anticipate that this training will accelerate recovery of postural and locomotor function during readaptation to gravitational environments following spaceflight facilitating neural adaptation to unit (Earth) and partial (Mars) gravity after long-duration spaceflight. The study calls for one group of subjects to perform the inflight treadmill training regimen while a control group of subjects performs only the nominal exercise procedures. Locomotor function in both groups is assessed before and after spaceflight using two tests of gait function: The Integrated Treadmill Locomotion Test (ITLT) and the Functional Mobility Test (FMT). The ITLT characterizes alterations in the integrated function of multiple sensorimotor subsystems responsible for the control of locomotion. This test calls for subjects to walk on a motorized treadmill while we assess changes in dynamic postural stability, head-trunk coordination, short-latency head stabilization responses, dynamic visual acuity, lower limb coordination strategies and gait cycle timing. To make these assessments we measure the following parameters while subjects walk on the treadmill: 1) full body 3-dimensional kinematics using a motion capture system (Motion Analysis Corp., Santa Rosa, CA); 2) the shock-wave transmitted from heel-strike to the head using triaxial accelerometers placed on the tibia and head (Entran, Fairfield, NJ); 3) vertical forces using an instumented treadmill (Kistler Instrument Corp., Amherst, NY); 4) Dynamic visual acuity using Landolt Cs presented on a laptop computer located 4m from the eyes and 5) Gait cycle timing using foot-switches (Motion Lab Systems, Inc., Baton Rouge, LA) attached to the plantar surface of each shoe at the heel and toe. The FMT evaluates s. subject's ability to perform challenging locomotor maneuvers similar to those encountered during an egress from a space vehicle. Subjects step over and duck under obstacles along with negotiating a series of pylons set up on a base of 10 cm thick medium density foam. The dependent measures for the FMT are time to complete the course and the number of obstacles touched. To date, we have collected pre and postflight locomotion data from Expeditions 5-9 who will serve as part of the control group for this study. Preliminary results comparing the recovery rates in gait control sub-systems obtained from the ITLT and FMT performance showed two recovery patterns: 1) a concordant recovery trend between gait control parameters and FMT performance indicating a restitution pattern of recovery and 2) gait controecovery that lagged recovery in FMT performance suggesting that improvement in locomotor function was attained through a pattern of substitution. These data suggest that recovery of postflight locomotor function may occur through adaptive mechanisms that lead to either restitution or substitution of function. Understanding the modes of postflight readaptation has implications for countermeasure development and testing and in astronaut postflight rehabilitation.

Bloomberg, J. J.↗

NASA's Biomedical Research Program

The biomedical research program has been established to investigate the major physiological and psychological problems encountered by man when he undertakes spaceflight. The program seeks to obtain a better definition of each problem, an understanding of its underlying mechanism, and ultimately a means of prevention. In pursuing these goals the program also includes a major effort to develop the research tools and procedures it needs where these are not being developed elsewhere. After almost twenty years of manned spaceflight activities and after a much longer period of space related ground-based research, the program now recognizes two characteristics of spaceflight which are truly unique to space. These are weightlessness and one specific form of radiation. In its present stage of maturity much of the research focuses on mechanisms underlying the basic responses of man and animals to weightlessness. The program consists of nine elements. Eight of these are referable to specific physiological problems that have either been encountered in previous manned spaceflight or which are anticipated to occur as spaceflights last longer, traverse steeper orbital inclinations, or are otherwise different from previous missions. The ninth addresses problems that have neither arisen nor can be reasonably predicted but are suspected on the basis of theoretical models, ground-based animal research, or for other reasons. The program's current emphasis is directed toward the motion sickness problem because of its relevance to Space Shuttle operations. Increased awareness and understanding of the radiation hazard has resulted in more emphasis being placed on the biological effects of high energy, high mass number particulate radiation and upon radiation protection . Cardiovascular and musculoskeleta1 studies are pursued in recognition of the considerable fundamental knowledge that must be acquired in these areas before effective countermeasures to the effects of repetitive or long-term flight can be devised. Major new avenues of research will deal with the psychological accompaniments of spaceflight and with mathematical modelling of physiological systems.

Ahn, Chung-Hae↗

Effect of Pharmacologically-Induced Hypovolemia on Aerobic Capacity

Decreased peak oxygen consumption (VO2pk) and an elevated exercise heart rate (HR) response are associated with a reduction in plasma volume (PV) after space flight and bed rest, a space flight analog. Reduced VO2pk and submaximal exercise tolerance would negatively impact an astronaut s ability to perform near maximal work that would be required in the event of an emergency. We previously have administered IV furosemide followed by a low salt diet to model PV loss and orthostatic intolerance observed after spaceflight. Purpose: To determine whether a pharmacologically-induced reduction in PV results in decreased VO2pk and elevated exercise HR response. Methods: Six subjects (5M, 1F) performed two graded peak cycle tests (work rate increased by 35 or 50 W every 3 min), once while normovolemic and once while hypovolemic. HR and expired respiratory gases were continuously measured. To induce hypovolemia, subjects were administered a single dose of IV furosemide (0.5 mg.kg-1) 30 hr before exercise testing and then consumed a low-salt diet (10 mEq.d(sup -1)). PV was measured using carbon monoxide rebreathing. Exercise HR and VO2 responses were quantified as the area under the curve (AUC) calculated over each quartile of the peak test, based on test time in the hypovolemia condition. Paired t-tests were used to test for differences in PV, VO2pk, and peak HR between conditions. Repeated-measures ANOVAs were used to test for differences in AUC between conditions. Results: PV (3.32+/-0.12 vs. 2.77+/-0.16 L, p<0.05) and VO2pk (3.30+/-0.67 vs. 2.90+/-0.57 L.min(sup -1), p<0.05) were lower during hypovolemia than during normovolemia, but peak HR was not different (187+/-5 vs. 187+/-5 bpm). The AUC for VO2 and HR was different (p<0.05) between conditions only in the highest quartile: HR was 4% higher and VO2 was 5% lower during the hypovolemia condition. Conclusion: The mean difference in VO2pk (-12%) between normovolemia and hypovolemia was similar to the mean difference in PV (-17%). Similar decreases in PV and VO2pk have been observed following short duration space flight, suggesting that pharmacologically-induced PV loss can be used to model microgravity-induced reductions in VO2pk.

Everett, Meghan E.↗

Progress in plant research in space

Progress is reviewed of spaceflight research conducted with plants between 1987 and 1992. Numerous plant experiments have been performed on spacecraft and sounding rockets in the past five years by scientists of the US, the former Soviet Union, Europe, and other areas. The experiments are categorized into three areas: gravity sensing, transduction, and response; development and reproduction; and metabolism, photosynthesis, and transport. The results of these experiments continue to demonstrate that gravity and/or other factors of spaceflight affect plants at the organismal, cellular, subcellular, and molecular levels, resulting in changes in orientation, development, metabolism, and growth. The challenge now is to truly dissect the effects of gravity from those of other spaceflight factors and to identify the basic mechanisms underlying gravity's effects.

Dutcher, F. Ronald↗

Stress-Induced Heat Shock Protein 40 and Immune Function in Altered Gravity

In space, astronauts are more susceptible to pathogens, viral reactivation and immunosuppression, which poses limits to their health and the mission. Interestingly, during space flight, stress-inducible heat shock proteins (HSP) are robustly induced, and the overexpression of HSPs have been implicated in immune dysregulation, therefore HSPs may be critically involved in regulating immune homeostasis. HSP40/DNAJ1 plays a major role in proper protein translation and folding. Its loss of function has been implicated in susceptibility to microbial infection, while its overexpression has been implicated in autoimmunity, collectively suggesting its complicated, but necessary, role in maintaining immunological function. To determine the role of HSP40 during stress-induced altered gravity conditions, wild-type and Hsp40 mutant Drosophila melanogaster were exposed to ground-based chronic hypergravity conditions, followed by quantitative PCR (qPCR) analysis of immune gene expression. In addition, larval hemocytes were collected to determine the functional output in response to E. coli bioparticle phagocytosis. Preliminary data indicates a required role for Hsp40 in strengthening immune function during stress-induced spaceflight in flies. In short, a critical need to evaluate the relationship between HSPs and immune suppression during space flight is necessary. Since space travel may become available to the general public in the not too distant future, and for the possibility of long-term space missions, a more comprehensive evaluation of the molecules responsible for immune dysfunction observed during space flight is required.

hypergravity↗

Heat Shock Protein 40 and Immune Function in Altered Gravity

In space, astronauts are more susceptible to pathogens, viral reactivation and immunosuppression, which poses limits to their health and the mission. Interestingly, during space flight, stress-inducible heat shock proteins (HSP) are robustly induced, and the overexpression of HSPs have been implicated in immune dysregulation, therefore HSPs may be critically involved in regulating immune homeostasis. HSP40/DNAJ1 plays a major role in proper protein translation and folding. Its loss of function has been implicated in susceptibility to microbial infection, while its overexpression has been implicated in autoimmunity, collectively suggesting its complicated, but necessary, role in maintaining immunological function. To determine the role of HSP40 during stress-induced altered gravity conditions, wild-type and Hsp40 mutant Drosophila melanogaster were exposed to ground-based chronic hypergravity conditions, followed by quantitative PCR (qPCR) analysis of immune gene expression. In addition, larval hemocytes were collected to determine the functional output in response to E. coli bioparticle phagocytosis. Preliminary data indicates a required role for Hsp40 in strengthening immune function during stress-induced spaceflight in flies. In short, a critical need to evaluate the relationship between HSPs and immune suppression during space flight is necessary. Since space travel may become available to the general public in the not too distant future, and for the possibility of long-term space missions, a more comprehensive evaluation of the molecules responsible for immune dysfunction observed during space flight is required.

hypergravity↗

Dynamic Anomaly Response and Integrated Analysis (DARIA): A Fault Investigation Toolset Supporting Earth-Independent Operations in Future Crewed Mars Missions

NASA's Moon to Mars Objectives outline a strategic vision for human spaceflight culminating in crewed missions to Mars. A critical component of this objective is the development of systems that are capable of being Earth-Independent Operated (EIO). A key aspect of EIO is the ability to rapidly detect, diagnose, and respond to anomalies in crew-supporting habitat and connected systems. To address this, the Dynamic Anomaly Response and Integrated Analysis (DARIA) architecture has been developed. DARIA incorporates a network of compact, wireless sensing devices called the System for Telemetry Amalgamation of Multimodal PrognosticS (STAMPS) for increased state awareness of EIO habitats. Able to perform on-the-fly data acquisition, STAMPS are connected to integrated anomaly data dashboards for crew visualization. DARIA is designed to seamlessly integrate into various off-world environments, including the International Space Station, Lunar Gateway, Artemis Base Camp, and future Mars habitats. By leveraging Commercial Off-The-Shelf (COTS) hardware, the NASA Internet of Things (NASA IoT) framework, and EIO fault detection methods, DARIA provides a cost-effective and adaptable solution for anomaly detection and response in EIO habitats.

Diagnostics↗

The influence of microgravity and spaceflight on columella cell ultrastructure in starch-deficient mutants of Arabidopsis

The ultrastructure of root cap columella cells was studied by morphometric analysis in wild-type, a reduced-starch mutant, and a starchless mutant of Arabidopsis grown in microgravity (F-microgravity) and compared to ground 1g (G-1g) and flight 1g (F-1g) controls. Seedlings of the wild-type and reduced-starch mutant that developed during an experiment on the Space Shuttle (both the F-microgravity samples and the F-lg control) exhibited a decreased starch content in comparison to the G-1g control. These results suggest that some factor associated with spaceflight (and not microgravity per se) affects starch metabolism. Elevated levels of ethylene were found during the experiments on the Space Shuttle, and analysis of ground controls with added ethylene demonstrated that this gas was responsible for decreased starch levels in the columella cells. This is the first study to use an on-board centrifuge as a control when quantifying starch in spaceflight-grown plants. Furthermore, our results show that ethylene levels must be carefully considered and controlled when designing experiments with plants for the International Space Station.

manned↗

America's shuttle returns to space

The Shuttle management structure, streamlined since the Challenger accident, is outlined. The associate administrators for space flight are identified and their responsibilities clearly spelled out. The NASA policy of assigning astronauts to management positions is described. A spaceflight safety panel is described. Non-managerial safety enhancement programs are outlined. These include: solid rocker booster changes, shuttle crew escape systems, and landing improvements.

Moorehead, Robert W.↗