Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral responsivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Coupling into and scattering from cylindrical structures covered periodically with metallic patches

Circular cylindrical structures covered periodically with metallic patches are considered. After an analogy to planar periodic surfaces is shown, formulations are presented for calculating induced currents on the curved surface. The equations are solved and results calculated for the specific case of periodic strips on the cylindrical surface. For a cylindrical structure a two-dimensional periodicity exists, as in a planar structure, while a spherical structure allows only a rotational periodicity. When the cylindrical structure is excited by the characteristic harmonic of the system, the spectral response of the transmitted field exhibits resonances that depend on the surface periodicity, as is known for planar structures. Since the cylindrical structure contains finite closed regions, the effects of resonances internal to the structure are seen and give additional information as compared to planar structures.

Cwik, Tom↗

HgCdTe for NASA EOS missions and detector uniformity benchmarks

Important NASA Earth Observing System (EOS) missions, Atmospheric Infrared Sounder (AIRS) and Moderate Resolution Imaging Spectrometer (MODIS-N), which require detector spectral response in the range of 14 to 17 microns at medium background flux levels and operation in the range of temperatures between 65 to 95 K, will be flown beginning in the next few years. Currently, a prime candidate detector technology for these missions is trapping-mode photoconductive HgCdTe devices. These devices can be tailored to the exact cutoff wavelengths required by those missions, and thus offer the performance advantages of an intrinsic detector which is ideally matched to the mission wavelength. Under the long wavelength-background-temperature conditions of these EOS missions, any detector will at best be thermal generation-recombination noise limited. Photoconductive devices are generally preferred under these circumstances, since at elevated temperatures their performance degrades with n(sub i) while for photovoltaic detectors performance degrades as n sub i(exp 2) n sub i is the intrinsic carrier concentration which is a function of alloy composition and temperature, but not doping. Very high performance trapping-mode photoconductive HgCdTe detectors have been developed which can be reproducibly fabricated. Detectivity (D asterisk) at 80K and 16 micron cutoff wavelength in excess of 10(exp 11) Jones has been measured for these devices. Power dissipation is at least two orders of magnitude less than conventional HgCdTe photoconductors - on the order of 0.12 W/cm(exp 2) compared with 12 W/cm(exp 2). EOS missions define thermal noise limited conditions for the long wavelength operating bands. Trapping-mode photoconductive HgCdTe detectors are linear under such conditions and responsivity is independent of background flux. At lower temperatures or high flux conditions in which background flux limits detector performance, trapping-mode detectors have a responsivity which varies with background flux. Internal calibration must be provided for radiometric measurements under the latter conditions (not an EOS mission concern). Liquid phase epitaxy is used to grow these HgCdTe device structures. This technique has been shown to give control of the cutoff wavelength on the order of 16 plus or minus 1 micron or less, both from run to run and across wafer dimensions of several centimeters on a side.

Norton, Paul R.↗

Low dark current photovoltaic multiquantum well long wavelength infrared detectors

The authors have, for the first time, demonstrated photovoltaic detection for an multiple quantum well (MQW) detector. With a blocking layer, the MQW detector exhibits Schottky I-V characteristics with extremely low dark current and excellent ideality factor. The dark current is 5 times 10(exp -14) A for an 100x100 square micron 10 micron detector at 40 K, 8 to 9 orders of magnitude lower than that of a similar 10 micron MQW detector without blocking layer. The ideality factor is about 1.01 to 1.05 at T = 40 to 80 K. The measured barrier height is consistent with the energy difference between first excited states and ground states, or the peak of spectral response. The authors also, for the first time, report the measured effective Richardson constant (A asterisk asterisk) for the GaAs/AlGaAs heterojunction using this blocking layer structure. The A asterisk asterisk is low approx. 2.3 A/sq cm/K(exp 2).

Wu, C. S.↗

Possibilities for LWIR detectors using MBE-grown Si(/Si(1-x)Ge(x) structures

Traditionally, long wavelength infrared (LWIR) detection in Si-based structures has involved either extrinsic Si or Si/metal Schottky barrier devices. Molecular beam epitaxially (MBE) grown Si and Si/Si(1-x)Ge(x) heterostructures offer new possibilities for LWIR detection, including sensors based on intersubband transitions as well as improved conventional devices. The improvement in doping profile control of MBE in comparison with conventional chemical vapor deposited (CVD) Si films has resulted in the successful growth of extrinsic Si:Ga, blocked impurity-band conduction detectors. These structures exhibit a highly abrupt step change in dopant profile between detecting and blocking layers which is extremely difficult or impossible to achieve through conventional epitaxial growth techniques. Through alloying Si with Ge, Schottky barrier infrared detectors are possible, with barrier height values between those involving pure Si or Ge semiconducting materials alone. For both n-type and p-type structures, strain effects can split the band edges, thereby splitting the Schottky threshold and altering the spectral response. Measurements of photoresponse of n-type Au/Si(1-x)Ge(x) Schottky barriers demonstrate this effect. For intersubband multiquntum well (MQW) LWIR detection, Si(1-x)Ge(x)/Si detectors grown on Si substrates promise comparable absorption coefficients to that of the Ga(Al)As system while in addition offering the fundamental advantage of response to normally incident light as well as the practical advantage of Si-compatibility. Researchers grew Si(1-x)Ge(x)/Si MQW structures aimed at sensitivity to IR in the 8 to 12 micron region and longer, guided by recent theoretical work. Preliminary measurements of n- and p-type Si(1-x)Ge(x)/Si MQW structures are given.

Hauenstein, Robert J.↗

IR detectors based on n-i-p-i superlattices

The principles of operation of n-i-p-i photodetectors are discussed. Special consideration is given to issues that are relevant to the performance of IR detectors such as noise, dark current, and surface effects. In addition, a novel IR detector that promises to provide information about the spectral distribution of the infrared radiation emitted from an object and, consequently, about its temperature, independent of the distance between detector and object is discussed. This detector makes use of the possibility to modulate the internal electric fields of an n-i-p-i superlattice with an applied voltage. By this technique the spectral responsivity of the detector may be controlled electrically and some information about the shape of the emission spectrum may be obtained.

Ruden, P. Paul↗

Fabrication of IrSi(3)/p-Si Schottky diodes by a molecular beam epitaxy technique

IrSi(3)/p-Si Schottky diodes have been fabricated by a molecular beam epitaxy technique at 630 C. Good surface morphology was observed for IrSi(3) layers grown at temperatures below 680 C, and an increasing tendency to form islands is observed in samples grown at higher temperatures. Good diode current-voltage characteristics were observed and Schottky barrier heights of 0.14-0.18 eV were determined by activation energy analysis and spectral response measurement.

Lin, T. L.↗

Analysis of forest disturbance using TM and AVHRR data

A methodology that will be used to determine the proportions of undisturbed, successional vegetation and recently disturbed land cover within coniferous forests using remotely sensed data from the advanced very high resolution radiometer (AVHRR) is presented. The method uses thematic mapper (TM) data to determine the proportions of the three stages of forest disturbance and regrowth for each AVHRR pixel in the sample areas, and is then applied to interpret all AVHRR imagery. Preliminary results indicate that there are predictable relationships between TM spectral response and the disturbance classes. Analysis of ellipse plots from a TM classification of the disturbed forested landscape indicates that the forest classes are separable in the red (0.63-0.69 micron) and near-infrared (0.76-0.90 micron) bands, providing evidence that the proportion of disturbance classes may be determined from AVHRR data.

Spanner, Michael A.↗

Assessment of regional biomass-soil relationships using vegetation indexes

The development of photosynthetic active biomass in different ecological conditions, as indicated by normalized difference vegetation indices (NDVIs) is compared by performing a stratified sampling (based on soil assocations) on data acquired over Indiana. Data from the NOAA-10 AVHRR were collected for the 1987 and 1988 growing seasons. An NDVI transformation was performed using the two optical bands of the sensor (0.58-0.68 microns and 0.72-1.10 microns). The NDVI is related to the amount of active photosynthetic biomass present on the ground. Samples of NDVI values over 45 fields representing eight soil associations throughout Indiana were collected to assess the effect of soil conditions and acquisition date on the spectral response of the vegetation, as shown by the NDVIs. Statistical analysis of results indicate that land-cover types (forest, forest/pasture, and crops), soil texture, and soil water-holding capacity have an important effect on vegetation biomass changes as measured by AVHRR data. Acquisition dates should be selected with condideration of the phenological stages of vegetation. Sampling of AVHRR data over extended areas should be stratified according to physiographic units rather than man-made boundaries. This will provide more homogeneous samples for statistical analysis.

Lozano-Garcia, D. Fabian↗

Nonscanning climate sensor study

The Nonscanning Climate Sensor represents a new instrument for climate research and global monitoring of the earth radiation budget. It contains a mosaic of array of detectors which measures the outgoing radiation of the earth in all directions without the need for mechanical scanning. The goal is to eliminate all moving parts and obtain highly calibrated measurements for up to one solar cycle (11 years) without being susceptible to mechanical failure. Over set intervals of time, the angular measurements are integrated up to produce total reflected and emitted flux values from each target area on the Earth. To achieve the require sensitivity while maintaining a flat spectral response, an improved dual cavity detector with digital control loop was developed. The detector is self calibrating to maintain high precision over the life of the instrument. Prototype detectors and a complete set of electronics with a microprocessor controller were fabricated and tested. Measurements show that the new detectors are more than an order of magnitude more sensitive than previous versions.

Hoffman, James W.↗

Effect of space exposure of pyroelectric infrared detectors

Pyroelectric detectors are one of many different types of infrared radiation detectors. The pyroelectric detectors are of interest for long term space use because they do not require cooling during operation. Also, they can detect at very long wavelengths and they have a relatively flat spectral response. A disadvantage is that the radiation must be chopped in order to be detected by a pyroelectric detector. The objective was to determine the effects of launch and space exposure on the performance of commercially available pyroelectric detectors. The approach was to measure certain detector parameters before and after flight and try to determine the amount and cause of the degradation. The experiment was passive: no data was taken during flight. It is concluded that lithium-tantalate and strontium-barium-niobate are suitable materials for pyroelectric detectors for long term space applications.

Robertson, James B.↗

Doppler lidar wind measurement with the edge technique

The edge technique is a new and powerful method for measuring small frequency shifts. Range resolved lidar measurements of winds can be made with high accuracy and high vertical resolution using the edge technique to measure the Doppler shift of an atmospheric backscattered signal from a pulsed laser. The edge technique can be used at near-infrared or visible wavelengths using well developed solid state lasers and detectors with various edge filters. In the edge technique, the laser frequency is located on the steep slope of the spectral response function of a high resolution optical filter. Due to the steep slope of the edge, very small frequency shifts cause large changes in measured signal. The frequency of the outgoing laser pulse is determined by measuring its location on the edge of the filter. This is accomplished by sending a small portion of the beam to the edge detection setup where the incoming light is split into two channels - an edge filter and an energy monitor channel. The energy monitor signal is used to normalize the edge filter signal for magnitude. The laser return backscattered from the atmosphere is collected by a telescope and directed through the edge detection setup to determine its frequency (location on the edge) in a similar manner for each range element. The Doppler shift, and thus the wind, is determined from a differential measurement of the frequency of the outgoing laser pulse and the frequency of the laser return backscattered from the atmosphere. We have conducted simulations of the performance of an edge lidar system using an injection seeded pulsed Nd:YAG laser at 1.06 microns. The central fringe of a Fabry-Perot etalon is used as a high resolution edge filter to measure the shift of the aerosol return.

Korb, C. Laurence↗

Effective area of the AXAF X-ray telescope - Dependence upon dielectric constants of coating materials

This study examines the dependence of the effective area of the AXAF X-ray telescope upon the complex dielectric constants of possible mirror coatings, over the energy range 0.1-10 keV. At energies near and above the astrophysically important iron-line complex near 6.7 keV, the effective area is very sensitive to the coating density on the three innermost of the telescope's six mirror pairs. Thus, it is desirable to achieve as high a density as feasible. The telescope's spectral response exhibits sharp features at absorption edges of the coating materials. In view of the exceptional energy resolution of the AXAF spectrometers and uncertainties in reflectivities (especially near absorption edges), the AXAF goal of 1-percent accuracy requires both the precise X-ray calibration of the telescope and improved modeling of the telescope and calibration sources. Presented here in the form of plots, the results are also available (on floppy disks) in tabular form.

Elsner, R. F.↗

A multi-aperture spectrometer design for the Atmospheric Infrared Sounder (AIRS)

The baseline multiaperture echelle spectrometer for the Atmospheric IR Sounder (AIRS) is described in terms of design and applications. The functional requirements for the optical design are set forth including the 1-K measurement goal, the 3.4-15.4 spectral bandpass, and the full global coverage twice daily. The multiaperture spectrometer is compared to the cross-dispersed spectrometer, and the multiaperture model is found to permit specific adjustments to the signal-to-noise ratio. The optical design of the spectrometer is described in terms of the focal-plane constraints, the multiaperture pupil-imaging relay, the spectrometer collimator, and the grating format and efficiency. The multiaperture design is found to have a good spectral-response function, and a 1.2 percent signal change is noted for a 95-percent unpolarized scene. The AIRS instrument is illustrated in its deployment configuration and is concluded to be capable of fulfilling the performance requirements.

Pagano, Robert↗

Evaluation of natural and man-made features using Landsat TM data

Landsat-5 TM data of a subscene of Washington, D.C. are utilized to distinguish man-made and natural surfaces through analysis of their spectral response. A quantitative measure of the separability and thus the ability to separate different surface features is calculated utilizing the quantity known as divergence, a measure of the dissimilarity between two distributions. The thermal band, TM band 6 (10.4-12.5 microns), was shown to improve the separability when replacing a visible band, but decreased the separability when included with the middle IR bands.

Ormsby, J. P.↗

Results from the calibration of the Extreme Ultraviolet Explorer instruments

The paper describes the main features and selected results of the calibration of the scientific instruments to be flown on the Extreme Ultraviolet Explorer in 1991. The instrument payload includes three grazing incidence scanning telescopes and an EUV spectrometer/deep survey instrument covering the spectral region 70-800 A. The measured imaging characteristics, the effective areas, and the details of spectral responses of the instruments are presented. Diagrams of the cross-sectional views of the scanning telescope and the deep-survey/spectrometer telescope are included.

Welsh, Barry Y.↗

Acousto-optic tunable filter imaging spectrometers

A remote sensing multispectral imaging instrument is being developed that uses a high resolution, fast programmable acoustooptic tunable filter (AOTF) as the spectral bandpass filter. A compact and fully computer controllable AOTF-based imaging spectrometer that operates in the visible wavelength range (0.5-0.8 microns) has been built and tested with success. A second imaging spectrometer operating in the near-infrared wavelength range (1.2-2.4 microns) is also under experimental investigation. The design criteria meeting various system issues, such as imaging quality, spectral response, and field of view (FOV), are discussed. An experiment using this AOTF imaging spectrometer breadboard is described.

Chao, Tien-Hsin↗

X-ray emission-line spectra of photoionized plasmas - Density sensitivity of the Fe L-shell series

The circumsource environments of accretion-powered X-ray sources are likely to support relatively dense (greater than 10 exp 11/cu cm) photoionized X-ray emission-line regions. The Fe L-shell ions provide a versatile class of plasma diagnostics in this regime, their multielectron structures resulting in diverse spectral phenomena. Attention is given to the spectral response of Fe L-shell ions to variations in electron density over the range 10 exp 11 to 10 exp 16/cu cm. It is found that density-sensitive line ratios exist in the wavelength interval 12-17 A for the ions Fe XVII-XXI. The prominent role of radiative recombination in the population kinetics distinguishes the density-sensitive Fe lines in photoionized plasmas from those which operate in coronal equilibrium plasmas. The results of detailed atomic modeling of these ions are presented and applications to spectroscopic observations of accretion-driven X-ray sources are discussed.

Liedahl, Duane A.↗