Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectrographs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Detailed measurements of the H beta line shape in a transient plasma using a fiber optics slit system.

Through the use of fiber optics, a series of very narrow slits have been constructed and placed at the exit plane of a spectrograph. Plasma radiation which is dispersed by the spectrograph is incident on the slits and is transmitted to separate phototubes via the quartz fibers. With this technique, time resolved measurements of the spectral shape of the hydrogen H beta line have been made and used to determine the electron density of a transient plasma. Data obtained in a shock tube indicated that the thermodynamic conditions behind the reflected shock in a mixture of 20% H2-80% He, at incident shock speeds of 12 to 14 km/sec and pressures of 66.6 to 133.3 N/sq m (0.5 to 1.0 mm Hg), correspond to theoretically predicted conditions. Immediately behind the incident shock at speeds of 17 to 24 km/sec the data indicate that the plasma reached equilibrium then demonstrated a drop in intensity which has been attributed to radiative cooling.

Stickford, G. H., Jr.↗

Development of television tubes for the large space telescope.

Princeton Observatory has been working for several years under NASA sponsorship to develop television type sensors to use in place of photographic film for space astronomy. This paper discusses the performance of an SEC-vidicon with a 25 mm x 25 mm active area, MgF2 window, and bi-alkali photocathode. Results from ground based use on the Coude spectrograph of the 200-inch Hale telescope are included. The intended use of this tube in an echelle spectrograph sounding rocket payload and on Stratoscope II for direct high resolution imagery is also discussed. The paper also discusses the Large Space Telescope image sensor requirements and the development of a larger television tube for this mission.

Lowrance, J. L.↗

Relative transition probabilities for krypton.

First experimental line strength data for the visible Kr II lines and for several of the more prominent Kr I lines are given. The spectroscopic light source used is the thermal plasma behind the reflected shock wave in a gas-driven shock tube. A 3/4-m spectrograph and a 1-m spectrograph were employed simultaneously to provide redundant photometry. The data are compared with other measurements and with theoretical calculations.

Miller, M. H.↗

Science instrumentation package, LST

The projected design of an optical instrument package for the large space telescope includes: a diffraction limited camera; low- and high-dispersion spectrographs; astrometric machines; photometers; polarimeters; F/12 camera; Fourier interferometer; infrared instrumentation; and a very high dispersion spectrographs.

Levin, G.↗

Change in center-limb profiles of faint Fraunhofer lines, 1

The precise photoelectric center-to-limb observations of the ten very faint lines (d sub O 10%) were made, using a double-pass spectrograph. The profiles of more intensive (d sub O 10%) were made, using a double-pass spectrograph. The profiles of more intensive lines (35 d sub O 10%) undergo a center-to-limb change from the V-shaped form with very faint wings to the U-shaped one without appreciable wings. The equivalent width changes differently and in general satisfies no simplified photospheric scheme.

Gurtovenko, E. A.↗

The data-handling problem with television recording of spectra.

A television tube is a useful way to record a many-element picture such as is obtained from an echelle spectrograph. The signal on the tube target is scanned and relayed to the data-processing center where it must be reconstituted into the scene that was present in the focal plane of the spectrograph camera. A typical television frame will contain four million bits of information which must be processed to remove transmission errors and random noise pulses, to remove periodic noise, to correct for optical and electrical distortion, to remove sensitivity variations across the face of the tube, to calibrate from the photoelectrons back to incident energy, and to provide a wavelength scale. Results of a study of these problems is presented.

Underhill, A. B.↗

Method of investigation of vibroacoustic characteristics of centrifugal pumps

A method for acoustical diagnostics of pumps is described which consists of taking sonograms of the pump, by means of an audio spectrograph. In distinction from usual analyzers, the spectrograph makes it possible to obtain a three-dimensional image of the signal being analyzed, in which its frequency-amplitude characteristics developed over time are depicted with a resolving power of 0.004 sec. As an example, a sonogram of an electrically driven pump, in the 40-4000 Hz frequency range, is presented. The amplitude ratios are determined on the sonogram by the contrast of individual contours, with an accuracy of 6 db.

Pokrovskiy, B. V.↗

The Apollo Telescope Mount on Skylab

The Apollo Telescope Mount (ATM) containing eight telescopes that cover wavelengths ranging from 2 to 6563 A is described. These are a white light coronograph, an XUV coronal spectroheliograph, and XUV spectrograph, an X-ray spectrographic telescope, a UV scanning polychromator/spectroheliometer, an X-ray telescope, and two H-alpha telescopes. The purpose, performance, and characteristic features of each of these instruments are discussed. The extremely high quality of the transmitted data is noted, and solar photographs are presented.

Ise, R.↗

Observations of narrow band solar burst structure at decameter wavelengths

A high-speed digital solar radio spectrograph was used in the investigation. This instrument made it possible to observe solar bursts with a time and frequency resolution not obtainable with conventional sweep-frequency spectrographs. A type III burst observed at 40 MHz is shown. The rise and the decay of the type III burst is smooth and gradual, with the decay time exceeding the rise time. An isophote diagram of the same burst is also presented along with some other events.

Mosier, S. R.↗

Note on ultraviolet hydroxyl observations of Comet Kohoutek

Observations of hydroxyl (OH) emission from Comet Kohoutek were made during the evening of 24 January 1974, from an altitude of 41,000 feet. The comet, of visual magnitude 5.5 at the time of observation, was photographed with an f/1.3 Maksutov slitless spectrograph of 150-mm aperture. This spectrograph used a double quartz prism as the dispersion element to isolate the OH radiation in the low-resolution spectrum. A nearly spherical coma of OH about three arc minutes diameter, as observed from an earth-comet distance of 0.88 AV, was photographed. The OH emission was the strongest feature in the spectrum and produced an irradiance of 3 billionths erg per sq cm per sec at the earth.

Harvey, G. A.↗

Small Astronomy Payloads for Spacelab

The workshop to define feasible concepts in the UV-optical 1R area for Astronomy Spacelab Payloads is reported. Payloads proposed include: high resolution spectrograph, Schmidt camera spectrograph, UV telescope, and small infrared cryogenic telescope.

Bohlin, R. C.↗

An experimental study of ultraviolet radiation behind incident normal shock waves in CO2 at Venusian entry speeds

Radiation intensity profiles behind incident normal shock waves in pure CO2 have been measured spectroscopically in the Langley Arc-Driven Shock Tube. These profiles, which were obtained for shock velocities between 9 and 13 km/sec and ambient densities corresponding to Venus altitudes between 100 and 80 km, were measured in the vacuum ultraviolet regime. Wavelengths of 127.7, 158.0, 177.5, and 195.0 nm were monitored simultaneously using a four-channel vacuum spectrograph equipped with sodium-salicylate-coated photomultipliers, thereby including the CO(4+) band system which is the most prominent radiator. Measured nonequilibrium overshoots are modeled to provide a means of estimating the effect of nonequilibrium radiation heating to the stagnation region of proposed aero-shells for Venusian entry. These results indicate a significant increase in radiative heating due to nonequilibrium effects. The measurements are believed to represent the most accurate data available on the effect of nonequilibrium radiative heat transfer for Venus entry. This accuracy is primarily due to improved spectrographic instrumentation, which is discussed in some detail regarding its application in related studies.

Nealy, J. E.↗

The Large Space Telescope - A new adventure

A description is presented of the Large Space Telescope (LST), which will be launched in 1982 and can accomodate four scientific instruments at any given time, permitting spectrographic and photometric observations between 1200 A in the UV and 1 mm in the IR. Basic elements of the LST are the optical telescope assembly, the scientific instruments (cameras, spectrographs, photometers, and an astrometer), and the support-systems module. Developmental as well as observational considerations are discussed, including various approaches to testing, maintenance, data transmission and processing, instrument calibration, housekeeping, and refurbishment. A possible mission scenario is outlined.

Friedlaender, F. M.↗

Absolute calibration of a hydrogen discharge lamp in the vacuum ultraviolet

A low-pressure hydrogen discharge lamp was calibrated for radiant intensity in the vacuum ultraviolet spectral region on an absolute basis and was employed as a laboratory standard source in spectrograph calibrations. This calibration was accomplished through the use of a standard photodiode detector obtained from the National Bureau of Standards together with onsite measurements of spectral properties of optical components used. The stability of the light source for use in the calibration of vacuum ultraviolet spectrographs and optical systems was investigated and found to be amenable to laboratory applications. The lamp was studied for a range of operating parameters; the results indicate that with appropriate peripheral instrumentation, the light source can be used as a secondary laboratory standard source when operated under preset controlled conditions. Absolute intensity measurements were recorded for the wavelengths 127.7, 158.0, 177.5, and 195.0 nm for a time period of over 1 month, and the measurements were found to be repeatable to within 11 percent.

Nealy, J. E.↗

The LST scientific instruments

Seven scientific instruments are presently being studied for use with the Large Space Telescope (LST). These instruments are the F/24 Field Camera, the F/48-F/96 Planetary Camera, the High Resolution Spectrograph, the Faint Object Spectrograph, the Infrared Photometer, and the Astrometer. These instruments are being designed as facility instruments to be replaceable during the life of the Observatory.

Levin, G. M.↗

Slow scan SEC vidicon system

A slow scan SEC vidicon system is described here. This system is coupled to the 152.4-cm (60-in) McMath telescope at Kitt Peak National Observatory. An anamorphic lens system is used to couple optically the vertical spectrograph to the vidicon system. The resolutin of the over-all system is 55 mA, while the resolution of the spectrograph alone is 50 mA. Actual observational results are used to evaluate the system performance.

Chiu, H.-Y.↗

White light and radio studies of the coronal transient of 14-15 September 1973. I - Material motions and magnetic field

Observations of a coronal transient event were obtained in white light by the Skylab coronagraph and at metric wavelengths by the radioheliograph and spectrograph at Culgoora, Australia, and the spectrograph-interferometer at Boulder, Colo. The continuum radio burst was found to originate above the outward-moving white-light loop, a region of compressed material headed by a bow wave. The computed density in the region of radio emission, based on either gyrosynchrotron or harmonic plasma radiation mechanisms, was approximately 10 times the ambient coronal density; this is compatible with the density deduced from the white-light observations. The magnetic-energy density derived from the radio observations was greater than 10 times the thermal energy density, marginally larger than the kinetic energy density in the fastest-moving portion of the transient, and considerably larger in most other regions. The ambient medium, the white-light front, the compression region, the loop, and the slower massive flow of material behind are each examined. It is found that the plasma was magnetically controlled throughout and that magnetic forces provided the principal mechanism for acceleration of the transient material from the sun.

Dulk, G. A.↗

Spectrophotometry of the transient X-ray source A0620-00

Optical observations of the transient X-ray source A0620-00 over the wavelength range from about 3200 to 6600 A are analyzed which were made with the 5-m Hale telescope using a multichannel spectrometer, a digital spectrograph with a cooled integrating SIT vidicon, and an image photon-counting system attached to the camera of the coude spectrograph. Infrared observations at 1.65, 2.2, and 3.5 microns are also examined. Individual spectral lines of special interest are discussed, the E(B-V) color excess is estimated to be about 0.40, and a distance of 1200 pc is adopted. Analysis of the continuous spectrum yields several simple binary models. A specific model is proposed in which one of the continuum sources is an optically thick object characterized by a model atmosphere at a temperature of 25,000 to 30,000 K and the second source is either a cool black body at 4000 K or a partially optically thick source of bound-free plus free-free radiation from a hydrogen gas with an electron temperature of at least 100,000 K. Some possible parameters of these sources and of the accretion disk are considered.

Oke, J. B.↗