Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface defects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Characterization of defect growth structures in ion plated films by scanning electron microscopy

Gold and copper films (0.2-2 micron thick) are ion plated on very smooth stainless steel 304 and mica surfaces. The deposited films are examined by SEM to identify the morphological growth of defects. Three types of coating defects are distinguished: nodular growth, abnormal or runaway growth, and spits. The potential nucleation sites for defect growth are analyzed to determine the cause of defect formation. It is found that nuclear growth is due to inherent surface microdefects, abnormal or runaway growth is due to external surface inclusions, and spits are due to nonuniform evaporation and ejection of droplets. All these defects have adverse effects on the coatings.

Spalvins, T.↗

Structure Sensitivity and Catalyst Restructuring for CO2 Electro-reduction on Copper

Abstract Cu is the most promising metal catalyst for CO 2 electroreduction (CO 2 RR) to multi-carbon products, yet the structure sensitivity of the reaction and the stability versus restructuring of the catalyst surface under reaction conditions remain controversial. Here, atomic scale simulations of surface energies and reaction pathway kinetics supported by experimental evidence unveil that CO 2 RR does not take place on perfect planar Cu(111) and Cu(100) surfaces but rather on steps or kinks. These planar surfaces tend to restructure in reaction conditions to the active stepped surfaces, with the strong binding of CO on defective sites acting as a thermodynamic driving force. Notably, we identify that the square motifs adjacent to defects, not the defects themselves, as the active sites for CO 2 RR via synergistic effect. We evaluate these mechanisms against experiments of CO 2 RR on ultra-high vacuum-prepared ultraclean Cu surfaces, uncovering the crucial role of step-edge orientation in steering selectivity. Overall, our study refines the structural sensitivity of CO 2 RR on Cu at the atomic level, highlights the self-activation mechanism and elucidates the origin of in situ restructuring of Cu surfaces during the reaction.

Science & Technology - Other Topics↗

Growth of Defect-Free 3C-Sic on 4H- and 6H-SIC Mesas Using Step-Free Surface Heteroepitaxy

A new growth process, herein named step-free surface heteroepitaxy, has achieved 3C-SiC films completely free of double positioning boundaries and stacking faults on 4H-SiC and 6H-SiC substrate mesas. The process is based upon the initial 2-dimensional nucleation and lateral expansion of a single island of 3C-SiC on a 4H- or 6H-SiC mesa surface that is completely free of bilayer surface steps. Our experimental results indicate that substrate-epilayer in-plane lattice mismatch (Delta/a = 0.0854% for 3C/4H) is at least partially relieved parallel to the interface in the initial bilayers of the heterofilm, producing an at least partially relaxed 3C-SiC film without dislocations that undesirably thread through the thickness of the epilayer. This result should enable realization of improved 3C-SiC devices.

Neudeck, Philip G.↗

Growth of Defect-Free 3C-SiC on 4H- and 6H-SiC Mesas Using Step-Free Surface Heteroepitaxy

A new growth process, herein named step-free surface heteroepitaxy, has achieved 3CSiC films completely free of double positioning boundaries and stacking faults on 4H-SiC and 6H-SiC substrate mesas. The process is based upon the initial 2-dimensional nucleation and lateral expansion of a single island of 3C-SiC on a 4H- or 6H-SiC mesa surface that is completely free of bilayer surface steps. Our experimental results indicate that substrate-epilayer in-plane lattice mismatch (delta a/a = 0.0854% for 3C/4H) is at least partially relieved parallel to the interface in the initial bilayers of the heterofilm, producing an at least partially relaxed 3C-SiC film without dislocations that undesirably thread through the thickness of the epilayer. This result should enable realization of improved 3C-SiC devices.

Neudeck, Philip G.↗

Solar maximum thermal surface assessment

The inflight repair of the Solar Maximum Spacecraft provided the first opportunity to make actual measurements of thermal control surfaces after 4 years exposure in low Earth orbit. Defective hardware was replaced by astronauts and returned to Earth while protected from reentry damage in the Shuttle Payload bay. A preliminary thermal surface assessment was made soon after retrieval in support of Space Telescope and other current spacecraft programs. This included visual examination and measurement of Kapton and Teflon film to determine change in thermal radiative properties after 4 years exposure to solar radiation and reaction with atomic oxygen. Comparative measurements were made with a portable solar reflectometer used for inspection of spacecraft hardware. Post flight measurements and observations reveal significant surface changes that further confirm Kapton mass loss predictions made prior to Solar Maximum repair. Details of thermal surface application, measurements and experimental results are presented and discussed.

Rhoads, G. D.↗

The Interplay of Surface Mount Solder Joint Quality and Reliability of Low Volume SMAs

Spacecraft electronics including those used at the Jet Propulsion Laboratory (JPL), demand production of highly reliable assemblies. JPL has recently completed an extensive study, funded by NASA's code Q, of the interplay between manufacturing defects and reliability of ball grid array (BGA) and surface mount electronic components.

Spacecraft electronics electronic assemblies J-lea↗

Thermographic Inspections Save Skins and Prevent Blackouts

Scanning thermography involves heating a component s surface and subsequently measuring the surface temperature, using an infrared camera to identify structural defects such as corrosion and disbonding. It is a completely noninvasive and noncontacting process. Scans can detect defects in conventional metals and plastics, as well as in bonded aluminum composites, plastic- and resinbased composites, and laminated structures. The apparatus used for scanning is highly portable and can cover the surface of a test material up to six times faster than conventional thermography. NASA scientists affirm that the technology is an invaluable asset to the airlines, detecting potential defects that can cause structural failure.In 1996, ThermTech Services, Inc., of Stuart, Florida, approached NASA in an effort to evaluate the technology for application in the power and process industries, where corrosion is of serious concern. ThermTech Services proceeded to develop the application for inspecting boiler waterwall tubing at fossil-fueled electric-generating stations. In 1999, ThermTech purchased the rights to NASA s patented technology and developed the specialized equipment required to apply the inspecting method to power plant components. The ThermTech robotic system using NASA technology has proved to be extremely successful and cost effective in performing detailed inspections of large structures such as boiler waterwalls and aboveground chemical storage tanks. It is capable of inspecting a waterwall, tank-wall, or other large surfaces at a rate of approximately 10 square feet per minute or faster.

Source record↗

Dynamic Scaling Analysis of Accelerated Irradiation Testing on Additive Manufacturing Materials by Positron Annihilation

The timely applications of Additive Manufacturing (AM) materials in nuclear environments require accelerated irradiation tests, mainly ion irradiation to enable rapid prototyping. Low dose ion irradiation would cause sub-nanostructure changes by generation of lattice defects, vacancies, vacancy clusters and voids and void swelling caused by cellular dislocations. Positron Annihilation Lifetime (PAL), a novel technology, sensitive towards sub-nanostructure morphology with high accuracy (about 10-7 vacancy per atom), supported by Transition Electron Microscope (TEM) would be applied to identify the type and total size of the defects. The subsequent PAL measurements and TEM surface studies would be followed by PAL analysis that includes sophisticated trapping model. The PAS results would become an input to dynamic scaling analysis (that predicts radiation effects from low dose studies for high dose effects), which incorporate mean-field theory model. The final effect is an in-depth understanding of the microstructure evolution of AM materials under ion irradiation which can be extrapolated to the studies of neutron irradiation, since ion-irradiation takes less time and do not cause the irradiation hazard. The working hypothesis is that PAL technology, that have excellent sensitivity to low-defect concentration would help to identify ion-induced material damage on the atomic and nano-scale level, which then could be extrapolated to understand the neutron damage better.

accelerated irradiation testing↗

Vacancy-Mediated Increases in Brine–Salt Surface Energies

Salt formations have been explored for the permanent isolation of spent nuclear fuel based on their high thermal conductivity, self-healing nature, and low hydraulic permeability to brine flow. Vacancy defect concentrations in salt complicate fracture mechanics not driven by dislocation dynamics and can influence the resulting surface structure. Classical molecular dynamic simulations were used to simulate tensile testing of salt crystals (halite) with vacancy defect concentrations of up to 0.5 defects/nm 3 . Increasing defect concentrations resulted in a decrease in ultimate tensile strength and fracture surface energies, driven by increased surface roughness rather than changes in the amount of surface area. Brine–salt surface energies of the fractured surfaces were 0.22 to 0.26 J/m 2 , significantly higher than values reported for atomically flat (100) surfaces at the same brine composition. This change in surface energy increased the brine–salt dihedral angle by ~27°. The dihedral angle threshold for percolation in salt is 60°, and a 27° increase due to rough fracture surfaces identifies a reduction in porosity percolation and a decrease in salt permeability. Therefore, bedded salt and salt domes may be even more stable than those previously predicted from dihedral angle calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic oxygen interactions with protected organic materials on the Long Duration Exposure Facility (LDEF)

The Long Duration Exposure Facility (LDEF) has provided an excellent opportunity to understand the nature of directed atomic oxygen interactions with protected polymers and composites. Although there were relatively few samples of materials with protective coatings on their external surfaces on LDEF which were exposed to a high atomic oxygen fluence, analysis of such samples has enabled an examination of the shape of atomic oxygen undercut cavities at defect sites in the protective coatings. Samples of front-surface aluminized (Kapton) polyimide were inspected by scanning electron microscopy to identify and measure crack defects in the aluminum protective coatings. After chemical removal of the aluminum coating, measurements were also made of the width of the oxidized undercut cavities below the crack defects. The LDEF flight undercut cavity geometries were then compared with Monte Carlo computational model undercut cavity predictions. The comparison of the LDEF results and computational modeling indicates agreement in specific undercut cavity geometries for atomic oxygen reaction probabilities dependent upon the 0.68 to 3.0 power of the energy. However, no single energy dependency was adequate to replicate flight results over a variety of aluminum crack widths.

Banks, Bruce A.↗

Pulse Phase Thermography for Defect Detection and Visualization

Pulse Phase Thermography (PPT) has been reported as a novel powerful technique of the thermal NDE. It employs application of the Discrete Fourier Transform (DFT) to thermal images obtained following flash heating of the front surface of a specimen. The computed phasegrams are excellent for defect visualization in a wide range of materials. This is in part due to their low sensitivity to uneven heating. This work is an attempt to analyze advantages and limitations of PPT. Results of application of the DFT to simulated temperature decays are presented. The temperature evolution on a surface has been simulated based on an analytical solution of the one-dimensional heat diffusion problem. A more sophisticated study has been done for different sizes of defects using numerical solution of the three-dimensional mathematical model. Capabilities of PPT for in-depth scanning and for monitoring of the material loss are discussed. The recommendations for the practical application of the PPT are presented. Experimental results obtained following these recommendations are reported.

Marinetti, Sergio↗

Precision Polishing of Ablator Capsules via in situ Process Monitoring and Machine Learning–Based Optimization

In inertial confinement fusion (ICF) experiments seeking output gains of unity and beyond, the quality of the ablator capsule is paramount for minimizing the hydrodynamic mix that quenches the central hot spot. Defects in the form of foreign particles or missing mass on the surface and within the wall of the capsule are primary offenders. High-density carbon capsules made for ICF experiments at the National Ignition Facility are precision polished to achieve surface smoothness on the order of a few nanometers as well as to minimize isolated defects in the form of pits. Given the critical role of this process, we are developing smart manufacturing techniques with the goal of elevating the efficiency of this process. Our approach is to use MEMS (micro-electromechanical systems)–based sensors to capture the fine vibration signals generated during the polishing process and combine them with synchronized visual feedback as needed. Beyond using these sensors for process monitoring, we use specific deep learning methods to analyze the data and extract correlations with both the process parameters and the final performance of the polishing run. Here, in this work, we describe the multiple fronts we have explored in this regard and the results we have gotten so far. This approach promises to have the potential to ultimately provide real-time feedback that can be used to ensure the progress of the run as well as a means for faster optimization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Precision Polishing of Spheres Via In-Situ Process Monitoring and Machine-Learning-Based Optimization

In inertial confinement fusion (ICF) experiments seeking output gains of unity and beyond, the quality of the ablator capsule is paramount for minimizing hydrodynamic mix that quenches the central hot spot. Defects in the form of foreign particles or missing mass on the surface and within the wall of the capsule are primary offenders. High density carbon capsules made for ICF experiments on the National Ignition Facility (NIF) are precision polished to achieve the surface smoothness in the order of a few nm as well as to minimize isolated defects in the form of pits. Given the critical role of this process, we are developing smart manufacturing techniques with goal of elevating the efficiency of this process. Our approach is to use MEMS-based sensors to capture the fine vibrational signals generated during the polishing process and combine it with synchronized visual feedback as needed. Beyond using these sensors for process monitoring, we use specific deep learning methods to analyze the data and extract correlations with both the process parameters and the final performance of the polishing run. Here, we describe the multiple fronts that we have explored in this regard and the results we have gotten so far. This approach promises to have the potential to ultimately provide real-time feedback that can be used for ensuring the progress of the run as well as a means for faster optimization.

36 MATERIALS SCIENCE↗

Structural Characterization of Crystalline Ice Nanoclusters

Water ice nanoclusters are useful analogs for studying a variety of processes that occur within icy grains in the extraterrestrial environment. The surface of ice nanoclusters prepared in the laboratory is similar to the surface of interstellar ice grains. In cold molecular clouds, the silicate cores of interstellar grains are typically approx. 100 nm in diameter and have a coating of impure amorphous water ice. Depositional, thermal and radiolytic processes leave the surface and subsurface molecules in a disordered state. In this state, structural defects become mobile and reactions of trapped gases and small molecules can occur. The large surface area of nanocluster deposits relative to their bulk allows for routine observation of such surface-mediated processes. Furthermore, the disordered surface and subsurface layers in nanocluster deposits mimic the structure of amorphous ice rinds found on interstellar dust grains. Transmission Electron Microscopy (TEM has been used tn characterize the crystallinity, growth mechanism, and size distribution of nanoclusters formed from a mixture of water vapor with an inert carrier gas that has been rapidly cooled to 77K. E M imaging reveals a Gaussian size distribution around a modal diameter that increases from approx. 15 to 30 nm as the percentage of water vapor within the mixture increases from 0.5 to 2.007, respectively . TEM bright and dark field imaging also reveals the crystalline nature of the clusters. h4any of the clusters show a mosaic structure in which crystalline domains originate at the center Other images show mirror planes that are separated by approx. 10 nm. Electron diffraction patterns of these clusters show that the clusters are composed of cubic ice with only a small hexagonal component. Further, the crystalline domain size is approximately the same as the modal diameter suggesting that the clusters are single crystals.

Blake, David↗

Stress-Activated Positive Holes (O− in a Matrix of O2–) Cause DNA Damage in Surface-Dwelling Organisms: Unveiling Mutation-Induced Secrets of Nature

Peroxy defects consist of pairs of tightly bonded oxygen anions in the –1 valence state such as in O3X/OO\YO3 with X, Y = Si4+, Al3+ etc. They commonly occur in igneous, metamorphic and many sedimentary rocks. When such rocks are stressed by tectonic forces, peroxy defects break up, releasing highly mobile electronic charge carriers: defect electrons in the O2– sublattice, i.e. unbound O–, known as “positive holes”, h•. The h• can flow out of stressed rock volumes, spreading far and wide, causing electric currents and electrochemical reactions. This study explores how the h• impact the electron flow in the electron transport chain (ETC) of organisms on the surface of rocks such as gabbro and granite. We found that, by forming hydroxyl radicals and superoxide anions, the h• disrupt the in vivo coordination of reduction-oxidation reactions that are essential for the timing of the redox cycle. Our observations show that stress activation of h• delays the sprouting of certain plant seeds and impedes the growth of yeast cultures, Saccharomyces cerevisiae. The h• induce mutations and affect plant development as evidenced by reduced stem length and leaf size. At the same time, the h• serve as a source of abiotic oxidation, capable of forming various organic compounds in situ. Through the generation of radical species that create new carbon-carbon bonds the h• facilitate the abiotic synthesis of hydrocarbons and other organic molecules essential to life, including porphyrins. Our findings highlight the intricate interplay between positive holes, redox timing, and biological processes, revealing their significant role in influencing the growth and development of organisms in tectonically stressed crustal environments. Understanding these effects enhances our broader comprehension of redox biology and the influence of environmental factors on cellular development in natural settings.

astrobiology↗

Site heterogeneity and broad surface-binding isotherms in modern catalysis: Building intuition beyond the Sabatier principle

Learning the science of heterogeneous catalysis and electrocatalysis always starts with the simple case of a flat, uniform surface with an ideal adsorbate. It has of course been recognized for a century that real catalysts are more complicated. For the increasingly complex catalysts of the 21st century, this Perspective argues that surface heterogeneity and non-ideal binding isotherms are central features, and their implications need to be incorporated in current thinking. A variety of systems are described herein where catalyst complexity leads to broad, non-Langmuirian surface isotherms for the binding of hydrogen atoms – and this occurs even for ideal, flat Pt(111) surfaces. Modern catalysis employs nanoscale materials whose surfaces have substantial step, edge, corner, impurity, and other defect sites, and they increasingly have both metallic and non-metallic elements M n X m , including metal oxides, chalcogenides, pnictides, carbides, doped carbons, etc. The surfaces of such catalysts are often not crystal facets of the bulk phase underneath, and they typically have a variety of potential active sites. Catalytic surfaces in operando are often non-stoichiometric, amorphous, dynamic, and impure, and often vary from one part of the surface to another. Understanding of the issues that arise at such nanoscale, multi-element catalysts is just beginning to emerge. Yet these catalysts are widely discussed using Brønsted/Bell-Evans-Polanyi (BEP) relations, volcano plots, Tafel slopes, the Butler-Volmer equation, and other linear free energy relations (LFERs), which all depend on the implicit assumption that the active sites are “similar” and that surface adsorption is close to ideal. These assumptions underly the ubiquitous intuition based on the Sabatier Principle, that the fastest catalysis will occur when key intermediates have free energies of adsorption that are not too strong nor too weak. Current catalysis research often aims to minimize the complexity of non-ideal isotherms through experimental and computational design (e.g., the use of single crystal surfaces), and these studies are the foundation of the field. In contrast, this Perspective argues that the heterogeneity of binding sites and binding energies is an inherent strength of these catalysts. Here, this diversity makes many nanoscale catalysts inherently a high-throughput screen wrapped in a tiny package. Only by making the heterogeneity part of the foundation of catalysis models, sorting the types of active sites and dissecting non-ideal binding isotherms, will modern catalysis learn to harness the inherent diversity of real catalysts. Controlling and exploiting diversity rather than avoiding it will help to optimize complex modern catalysts and catalytic conditions.

Mayer, James M.↗

An experimental process parameter study on the identification of defects in additively fabricated Al6061 with laser powder bed fusion

Additively fabricated metal parts using laser powder bed fusion (L-PBF) possess sophisticated morphology due to the recurrent use of laser-induced metal powder melting and solidification. The surface and 3D morphology of these parts often include defects in the form of protrusions, depressions, pores, voids, keyholes, or cracks that are known to be influenced by laser scanning paths and layer-to-layer processing. Such inconsistent part quality hampers the extensive adoption of L-PBF. Pores and cracks are detrimental to the fatigue life of the parts and components. Quantifying and controlling part defects and optimizing processing and scanning strategy parameters adaptively in real-time through in situ monitoring systems are highly desired. This study investigates the optimization of experimental process parameters (power, scan velocity, and hatch spacing) and their effects on the cracking and porosity of Al6061 alloy using machine learning techniques. Multi-objective optimization is formulated and conducted to determine the L-PBF parameters that minimize both porosity and crack densities.

36 MATERIALS SCIENCE↗

Handheld White Light Interferometer for Measuring Defect Depth in Windows

Accurate quantification of defects (scratches and impacts) is vital to the certification of flight hardware and other critical components. The amount of damage to a particular component contributes to the performance, reliability, and safety of a system, which ultimately affects the success or failure of a mission or test. The launch-commit criteria on a Space Shuttle Orbiter window are governed by the depth of the defects that are identified by a visual inspection. This measurement of a defect is not easy to obtain given the environment, size of the defect, and location of the window(s). The determination of depth has typically been performed by taking a mold impression and measuring the impression with an optical profiling instrument. Another method of obtaining an estimate of the depth is by using a refocus microscope. To use a refocus microscope, the surface of the glass and bottom of the defect are, in turn, brought into focus by the operator. The amount of movement between the two points corresponds to the depth of the defect. The refocus microscope requires a skilled operator and has been proven to be unreliable when used on Orbiter windows. White light interferometry was chosen as a candidate to replace the refocus microscope. The White Light Interferometer (WLI) was developed to replace the refocus microscope as the instrument used for measuring the depth of defects in Orbiter windows. The WLI consists of a broadband illumination source, interferometer, detector, motion control, displacement sensor, mechanical housing, and support electronics. The illumination source for the WLI is typically a visible light emitting diode (LED) or a near-infrared superluminescent diode (SLD) with power levels of less than a milliwatt. The interferometer is a Michelson configuration consisting of a 1-in. (2.5-cm) cube beam splitter, a 0.5-in. (1.3-cm) optical window as a movable leg (used to closely match the return intensity of the fixed leg from the window), and a mirrored prism to fold the optics into the mechanical housing. The detector may be one of many C-mount CCD (charge-coupled device) cameras. Motion is provided by a commercial nanostepping motor with a serial interface. The displacement sensor is a custom device specifically designed for this application. The mechanical housing and support electronics were designed to integrate the various components into an instrument that could be physically handled by a technician and easily transported.

Youngquist, Robert↗