Search NASA⌕ Search

SEARCH · Search NASA

Results for “techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

A Coordinated Focused Ion Beam/Ultramicrotomy Technique for Serial Sectioning of Hayabusa Particles and Other Returned Samples

Recent sample return missions, such as NASA's Stardust mission to comet 81P/Wild 2 and JAXA's Hayabusa mission to asteroid 25143 Itokawa, have returned particulate samples (typically ~5-50 μm) that pose tremendous challenges to coordinated analysis using a variety of nano- and micro-beam techniques. The ability to glean maximal information from individual particles has become increasingly important and depends critically on how the samples are prepared for analysis. This also holds true for other extraterrestrial materials, including interplanetary dust particles, micrometeorites and lunar regolith grains. Traditionally, particulate samples have been prepared using microtomy techniques (e.g., [1]). However, for hard mineral particles ≳20 μm, microtome thin sections are compromised by severe chatter and sample loss. For these difficult samples, we have developed a hybrid technique that combines traditional ultramicrotomy with focused ion beam (FIB) techniques, allowing for the in situ investigation of grain surfaces and interiors. Using this method, we have increased the number of FIB-SEM prepared sections that can be recovered from a particle with dimensions on the order of tens of μms. These sections can be subsequently analyzed using a variety of electron beam techniques. Here, we demonstrate this sample preparation technique on individual lunar regolith grains in order to study their space-weathered surfaces. We plan to extend these efforts to analyses of individual Hayabusa samples.

Berger, E. L.↗

Advanced Intensity-Modulation Continuous-Wave Lidar Techniques for ASCENDS O2 Column Measurements

Global atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity- Modulated Continuous-Wave (IM-CW) lidar techniques are investigated as a means of facilitating CO2 measurements from space to meet the ASCENDS measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) modulation technique to uniquely discriminate surface lidar returns from intermediate aerosol and cloud contamination. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of optically thin clouds, thereby eliminating the need to correct for sidelobe bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new hyperfine interpolation techniques that takes advantage of the periodicity of the modulation waveforms. This approach works well for both BPSK and linear swept-frequency modulation techniques. The BPSK technique under investigation has excellent auto-correlation properties while possessing a finite bandwidth. A comparison of BPSK and linear swept-frequency is also discussed in this paper. These results are extended to include Richardson-Lucy deconvolution techniques to extend the resolution of the lidar beyond that implied by limit of the bandwidth of the modulation, where it is shown useful for making tree canopy measurements.

Campbell, Joel F.↗

A Synthesis of Star Calibration Techniques for Ground-Based Narrowband Electron-Multiplying Charge-Coupled Device Imagers Used in Auroral Photometry

A technique is presented for the periodic and systematic calibration of ground-based optical imagers. It is important to have a common system of units (Rayleighs or photon flux) for cross comparison as well as self-comparison over time. With the advancement in technology, the sensitivity of these imagers has improved so that stars can be used for more precise calibration. Background subtraction, flat fielding, star mapping, and other common techniques are combined in deriving a calibration technique appropriate for a variety of ground-based imager installations. Spectral (4278, 5577, and 8446 A ) ground-based imager data with multiple fields of view (19, 47, and 180 deg) are processed and calibrated using the techniques developed. The calibration techniques applied result in intensity measurements in agreement between different imagers using identical spectral filtering, and the intensity at each wavelength observed is within the expected range of auroral measurements. The application of these star calibration techniques, which convert raw imager counts into units of photon flux, makes it possible to do quantitative photometry. The computed photon fluxes, in units of Rayleighs, can be used for the absolute photometry between instruments or as input parameters for auroral electron transport models.

Grubbs, Guy II↗

Quantitative Image Analysis Techniques with High-Speed Schlieren Photography

Optical flow visualization techniques such as schlieren and shadowgraph photography are essential to understanding fluid flow when interpreting acquired wind tunnel test data. Output of the standard implementations of these visualization techniques in test facilities are often limited only to qualitative interpretation of the resulting images. Although various quantitative optical techniques have been developed, these techniques often require special equipment or are focused on obtaining very precise and accurate data about the visualized flow. These systems are not practical in small, production wind tunnel test facilities. However, high-speed photography capability has become a common upgrade to many test facilities in order to better capture images of unsteady flow phenomena such as oscillating shocks and flow separation. This paper describes novel techniques utilized by the authors to analyze captured high-speed schlieren and shadowgraph imagery from wind tunnel testing for quantification of observed unsteady flow frequency content. Such techniques have applications in parametric geometry studies and in small facilities where more specialized equipment may not be available.

Pollard, Victoria J.↗

A Physics-Based Antarctic Melt Detection Technique: Combining Advanced Microwave Scanning Radiometer 2, Radiative-Transfer Modeling, and Firn Modeling

Surface melt on ice shelves has been linked to hydrofracture and subsequent ice shelf breakup. Since the 1990s, scientists have been using microwave radiometers to detect melt on ice shelves and ice sheets by applying various statistical thresholding techniques to identify significant increases in brightness temperature that are associated with melt. In this study, instead of using a fixed threshold, we force the Snow Radiative Transfer model (SMRT) with outputs from the Community Firn Model (CFM) to create a dynamic, physics-based threshold for melt. In the process, we also combine our method with statistical thresholding techniques and produce microwave grain size information in the process. We run this “Hybrid Method” across the Larsen C ice shelf as well as thirteen sites on the Antarctic Ice Sheet. Melt and non-melt days from the Hybrid Method and three statistical thresholding techniques match with surface energy balance within 94±1%; the effect of melt on the passive microwave is mostly binary and thus largely detectable by statistical thresholding techniques as well as physics-based techniques. Rather than always replacing statistical thresholding techniques with the Hybrid Method, we recommend using the Hybrid Method in studies where melt volume or grain size is of interest. In this study, we show that the Hybrid Method can be used to (a) model dry snow brightness temperatures of Antarctic snow and (b) derive a measure of grain size; therefore, it is an important step forwards towards using firn and radiative transfer modeling to quantify melt rather than to simply detect melt days.

Marissa E Dattler↗

Flip-chip and backside techniques.

State-of-the-art techniques for failure localization and design modification through bulk silicon are essential for multi-level metallization and new, flip chip packaging methods. The tutorial reviews the transmission of light through silicon, sample preparation, and backside defect localization techniques that are both currently available and under development. The techniques covered include emission microscopy, scanning laser microscope based techniques (electrooptic techniques, LIVA and its derivatives), and other non-IR based tools (FIB, e-beam techniques, etc.).

99 GENERAL AND MISCELLANEOUS↗

Review of pyroelectric thermal energy harvesting and new MEMs based resonant energy conversion techniques

Harvesting electrical energy from thermal energy sources using pyroelectric conversion techniques has been under investigation for over 50 years, but it has not received the attention that thermoelectric energy harvesting techniques have during this time period. This lack of interest stems from early studies which found that the energy conversion efficiencies achievable using pyroelectric materials were several times less than those potentially achievable with thermoelectrics. More recent modeling and experimental studies have shown that pyroelectric techniques can be cost competitive with thermoelectrics and, using new temperature cycling techniques, has the potential to be several times as efficient as thermoelectrics under comparable operating conditions. This paper will review the recent history in this field and describe the techniques that are being developed to increase the opportunities for pyroelectric energy harvesting. The development of a new thermal energy harvester concept, based on temperature cycled pyroelectric thermal-to-electrical energy conversion, are also outlined. The approach uses a resonantly driven, pyroelectric capacitive bimorph cantilever structure that can be used to rapidly cycle the temperature in the energy harvester. The device has been modeled using a finite element multi-physics based method, where the effect of the structure material properties and system parameters on the frequency and magnitude of temperature cycling, and the efficiency of energy recycling using the proposed structure, have been modeled. Results show that thermal contact conductance and heat source temperature differences play key roles in dominating the cantilever resonant frequency and efficiency of the energy conversion technique. This paper outlines the modeling, fabrication and testing of cantilever and pyroelectric structures and single element devices that demonstrate the potential of this technology for the development of high efficiency thermal-to-electrical energy conversion devices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nondestructive determination of plutonium mass in spent fuel: prelliminary modeling results using the passive neutron Albedo reactivity technique

There are a variety of motivations for quantifying plutonium (Pu) in spent fuel assemblies by means of nondestructive assay (NDA) including the following: strengthening the capability of the International Atomic Energy Agency (LAEA) to safeguard nuclear facilities, quantifying shipper/receiver difference, determining the input accountability value at pyrochemical processing facilities, providing quantitative input to burnup credit and final safeguards measurements at a long-term repository. In order to determine Pu mass in spent fuel assemblies, thirteen NDA techniques were identified that provide information about the composition of an assembly. A key motivation of the present research is the realization that none of these techniques, in isolation, is capable of both (1) quantifying the Pu mass of an assembly and (2) detecting the diversion of a significant number of rods. It is therefore anticipated that a combination of techniques will be required. A 5 year effort funded by the Next Generation Safeguards Initiative (NGSI) of the U.S. DOE was recently started in pursuit of these goals. The first two years involves researching all thirteen techniques using Monte Carlo modeling while the final three years involves fabricating hardware and measuring spent fuel. Here, we present the work in two main parts: (1) an overview of this NGSI effort describing the motivations and approach being taken; (2) The preliminary results for one of the NDA techniques - Passive Neutron Albedo Reactivity (PNAR). The PNAR technique functions by using the intrinsic neutron emission of the fuel (primarily from the spontaneous fission of curium) to self-interrogate any fissile material present. Two separate measurements of the spent fuel are made, both with and without cadmium (Cd) present. The ratios of the Singles, Doubles and Triples count rates obtained in each case are analyzed; known as the Cd ratio. The primary differences between the two measurements are the neutron energy spectrum and fluence in the spent fuel. By varying the thickness of the cadmium layer surrounding the spent fuel, a high and a low neutron-energy-measurement condition can be produced. The neutron detectors can be used to detect total neutrons (Singles) and/or Doubles and/or Triples. If the geometry of the measurement situation is unchanged between the two measurements, the change in the Cd ratio between these two measurements can be attributed to a change in the fissile content of the sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Survey of Architectural Techniques For Improving Cache Power Efficiency

Modern processors are using increasingly larger sized on-chip caches. Also, with each CMOS technology generation, there has been a significant increase in their leakage energy consumption. For this reason, cache power management has become a crucial research issue in modern processor design. To address this challenge and also meet the goals of sustainable computing, researchers have proposed several techniques for improving energy efficiency of cache architectures. This paper surveys recent architectural techniques for improving cache power efficiency and also presents a classification of these techniques based on their characteristics. For providing an application perspective, this paper also reviews several real-world processor chips that employ cache energy saving techniques. The aim of this survey is to enable engineers and researchers to get insights into the techniques for improving cache power efficiency and motivate them to invent novel solutions for enabling low-power operation of caches.

architectural techniques↗

Retrospective Study of Rapid-Exchange Monorail Versus Over-the-Wire Technique for Femoropopliteal Angioplasty

PurposeThe purpose of this study was to compare procedural outcome of rapid-exchange (RX) monorail versus conventional over-the-wire (OTW) technique for femoropopliteal angioplasty.Materials and MethodsDemographic data, procedure details, angioplasty success, and complications of 328 consecutive percutaneous transluminal angioplasties (PTAs) were collected from a prospective database and retrospectively analyzed. Procedure details included duration of fluoroscopy, area-dose product, amount of contrast agent, sheath sizes, access route, length of stenosis, presence of total occlusion, technical and anatomical success (residual stenosis <30% in the absence of complications), need for bail-out stenting, and periprocedural complications. The RX technique alone was used in 102 of 328 cases (31%); the OTW technique, in 226 of 328 of cases (68%).ResultsTechnical success was 98% for the RX versus 95.4% for the OTW technique (p = 0.2). A significantly greater number of stents had to be implanted due to angioplasty failure when the OTW technique was used (RX, 5.9%; OTW, 13.7%; p = 0.04). There were no significant differences in fluorocopy time, dose-area product, or amount of contrast medium used. The RX system facilitated the use of smaller sheath sizes (5 Fr = 38% and 6 Fr = 59% for RX versus 5 Fr = 16.8% and {>=}6 Fr = 82.5% for OTW) but showed only a tendency toward lower overall complication rates (16.6% [17/102] in the RX group versus 19.9% [45/226] in the OTW group; p = 0.09). There was no effect on length of hospitalization. RX monorail systems were not associated with higher procedural costs when compared to conventional OTW technique.ConclusionWe conclude that RX monorail systems seem to enhance the technical success of femoropopliteal angioplasty. Although smaller sheath sizes can be used due to the lower profile of the RX systems, there is only a tendency toward lower complication rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poster — Thur Eve — 03: Application of the non-negative matrix factorization technique to [{sup 11}C]-DTBZ dynamic PET data for the early detection of Parkinson's disease

In this work, a class of non-negative matrix factorization (NMF) technique known as alternating non-negative least squares, combined with the projected gradient method, is used to analyze twenty-five [{sup 11}C]-DTBZ dynamic PET/CT brain data. For each subject, a two-factor model is assumed and two factors representing the striatum (factor 1) and the non-striatum (factor 2) tissues are extracted using the proposed NMF technique and commercially available factor analysis software “Pixies”. The extracted factor 1 and 2 curves represent the binding site of the radiotracer and describe the uptake and clearance of the radiotracer by soft tissues in the brain, respectively. The proposed NMF technique uses prior information about the dynamic data to obtain sample time-activity curves representing the striatum and the non-striatum tissues. These curves are then used for “warm” starting the optimization. Factor solutions from the two methods are compared graphically and quantitatively. In healthy subjects, radiotracer uptake by factors 1 and 2 are approximately 35–40% and 60–65%, respectively. The solutions are also used to develop a factor-based metric for the detection of early, untreated Parkinson's disease. The metric stratifies healthy subjects from suspected Parkinson's patients (based on the graphical method). The analysis shows that both techniques produce comparable results with similar computational time. The “semi-automatic” approach used by the NMF technique allows clinicians to manually set a starting condition for “warm” starting the optimization in order to facilitate control and efficient interaction with the data.

60 APPLIED LIFE SCIENCES↗

Light Water Reactor Sustainability Program Interrogation of Alkali-Silica Reaction Degraded Concrete Samples using Acoustic and Thermal Techniques to Support Development of a Structural Health Monitoring Framework

Assessment and management of aging concrete structures in nuclear power plants require a more systematic approach than simple reliance on existing code margins of safety. Health monitoring of concrete structures is performed to understand the current condition of a structure based on heterogeneous measurements and then produce high-confidence actionable information regarding structural integrity. This information can then be used to support operational and maintenance decisions. The proposed diagnosis and prognosis framework consists of four elements: health monitoring, data analytics, uncertainty quantification, and prognosis. The objectives of this ongoing research project focuses on health monitoring and data analytics of concrete slab cast, which is cured using four pockets of reactive aggregates: pure silica, wells, placitas, and spratt. A controlled concrete slab with four aggregates is cast at Vanderbilt University in representative conditions to accelerate degradation due to alkali-silica reaction (ASR). Four nondestructive evaluation (NDE) techniques (thermography, mechanical deformation measurements, nonlinear impact resonance-acoustic spectroscopy, and vibro-acoustic modulation) are used to examine the degraded concrete slab. Heterogeneous data from these techniques are analyzed for assessing ASRrelated degradation in concrete samples. In addition, this report discusses thermography assessment of three cement bricks cured under different conditions to accelerate ASR-related degradation. The application of the digital image correlation technique to study ASR-related degradation on a large concrete sample at the University of Tennessee Knoxville is discussed and initial observations are presented in this report. The results from the data analysis of the NDE techniques on concrete slab cured at Vanderbilt University are discussed in detail in this report. The major outcome of the analysis suggests that the nonlinear impact resonance acoustic spectroscopy is able to detect potential degradation in a concrete slab but is unable to locate or isolate the degradation. Alternatively, the vibro-acoustic technique is able to detect degradation and locate the damage in the concrete slab cast. The outcomes supports development of a structural health monitoring framework.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PID techniques: Alternatives to RICH Methods

In this review article we discuss the recent progress in PID techniques other than the RICH methods. In particular we mention the recent progress in the Transition Radiation Detector (TRD), dE/dx cluster counting, and Time Of Flight (TOF) techniques. The TRD technique is mature and has been tried in many hadron colliders. It needs space though, about 20cm of detector radial space for every factor of 10 in the {pi}/e rejection power, and this tends to make such detectors large. Although the cluster counting technique is an old idea, it was never tried in a real physics experiment. Recently, there are efforts to revive it for the SuperB experiment using He-based gases and waveform digitizing electronics. A factor of almost 2 improvement, compared to the classical dE/dx performance, is possible in principle. However, the complexity of the data analysis will be substantial. The TOF technique is well established, but introduction of new fast MCP-PMT and G-APD detectors creates new possibilities. It seems that resolutions below 20-30ps may be possible at some point in the future with relatively small systems, and perhaps this could be pushed down to 10-15ps with very small systems, assuming that one can solve many systematic issues. However, the cost, rate limitation, aging and cross-talk in multi-anode devices at high BW are problems. There are several groups working on these issues, so progress is likely. Table 6 summarizes the author's opinion of pros and cons of various detectors presented in this paper based on their operational capabilities. We refer the reader to Ref.40 for discussion of other more general limits from the PID point of view.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deciphering the Reaction Mechanism of Lithium–Sulfur Batteries by In Situ/Operando Synchrotron-Based Characterization Techniques

Lithium-sulfur (Li-S) batteries have received extensive attention as one of the most promising next-generation energy storage systems, mainly because of their high theoretical energy density and low cost. Yet, the practical application of Li-S batteries has been hindered by technical obstacles arising from the polysulfide shuttle effect and poor electronic conductivity of sulfur and discharge products. Therefore, it is of critical significance for understanding the underlying reaction mechanism of Li-S batteries to circumvent these problems and improve the overall battery performance. Advanced characterization techniques, especially synchrotron-based X-ray techniques, have been widely applied to the mechanistic understanding of Li-S batteries. Specifically, in situ/operando synchrotron-based techniques allows chemical and structural evolution to be directly observed under real operation conditions. Here, current progress in the understanding of the operating principles of Li-S batteries based on in situ/operando synchrotron-based techniques, including X-ray absorption spectroscopy, X-ray diffraction, and X-ray microscopy, is reviewed. The aim of this progress report is to provide a comprehensive treatise on in situ/operando synchrotron-based techniques for mechanism understanding of Li-S batteries, and thereby provide guidance for optimizing their overall electrochemical performances.

25 ENERGY STORAGE↗

Standardization of chemical analytical techniques for pyrolysis bio-oil: history, challenges, and current status of methods

Here, we discuss the standardization of analytical techniques for pyrolysis bio-oils, including the current status of methods, and our opinions on future directions. First, the history of past standardization efforts is summarized, and both successful and unsuccessful validation of analytical techniques highlighted. The majority of analytical standardization studies to-date has tested only physical characterization techniques. In this paper, we present results from an international round robin on the validation of chemical characterization techniques for bio-oils. Techniques tested included acid number, carbonyl titrations using two different methods (one at room temperature and one at 80 °C), 31 P NMR for determination of hydroxyl groups, and a quantitative gas chromatography–mass spectrometry (GC-MS) method. Both carbonyl titration and acid number methods have yielded acceptable inter-laboratory variabilities. 31 P NMR produced acceptable results for aliphatic and phenolic hydroxyl groups, but not for carboxylic hydroxyl groups. As shown in previous round robins, GC-MS results were more variable. Reliable chemical characterization of bio-oils will enable upgrading research and allow for detailed comparisons of bio-oils produced at different facilities. Reliable analytics are also needed to enable an emerging bioenergy industry, as processing facilities often have different analytical needs and capabilities than research facilities. We feel that correlations in reliable characterizations of bio-oils will help strike a balance between research and industry, and will ultimately help to -determine metrics for bio-oil quality. Lastly, the standardization of additional analytical methods is needed, particularly for upgraded bio-oils.

09 BIOMASS FUELS↗

Evaluation of hydrograph separation techniques with uncertain end-member composition

Hydrograph separation is one of many approaches used to analyse shifts in source water contributions to stream flow resulting from climate change in remote watersheds. Understanding these shifts is vital, as shifts in source water contributions to a stream can shape water management decisions. Because remote watersheds are often inaccessible and have poorly characterized contributing water sources, or end-members, it is critical to understand the implications of using different hydrograph separation techniques in these data-limited environments. To explore the uncertainty associated with different techniques, results from two hydrograph separation techniques, mass balance and principle component analysis, were compared using 3 years of aqueous geochemical data from the East River watershed located in the Elk Mountains of Central Colorado. Solute concentrations of the end-members were characterized by both a limited set of direct chemical measurements of different sources and detailed seasonal instream chemistry to examine the influences of uncertain end-member compositions in a data-limited environment. Annual volumetric end-member contributions to stream flow had relatively good agreement across separation techniques. Large variations in time were observed in the hydrograph separations, depending on the end-member type, and estimated flow contributions varied between the selected solutes. End-member concentrations characterized by stream chemistry showed several limitations including a reduced number of distinguishable end-members and differences in timing of flow contributions. Here the results highlight the benefits of using multiple hydrograph separation techniques by providing a ‘weight-of-evidence’ approach to environments with limited end-member concentration data.

54 ENVIRONMENTAL SCIENCES↗

Assessment of Snared-Loop Technique When Standard Retrieval of Inferior Vena Cava Filters Fails

Purpose To identify the success and complications related to a variant technique used to retrieve inferior vena cava filters when simple snare approach has failed. Methods A retrospective review of all Cook Guenther Tulip filters and Cook Celect filters retrieved between July 2006 and February 2008 was performed. During this period, 130 filter retrievals were attempted. In 33 cases, the standard retrieval technique failed. Retrieval was subsequently attempted with our modified retrieval technique. Results The retrieval was successful in 23 cases (mean dwell time, 171.84 days; range, 5-505 days) and unsuccessful in 10 cases (mean dwell time, 162.2 days; range, 94-360 days). Our filter retrievability rates increased from 74.6% with the standard retrieval method to 92.3% when the snared-loop technique was used. Unsuccessful retrieval was due to significant endothelialization (n = 9) and caval penetration by the filter (n = 1). A single complication occurred in the group, in a patient developing pulmonary emboli after attempted retrieval. Conclusion The technique we describe increased the retrievability of the two filters studied. Hook endothelialization is the main factor resulting in failed retrieval and continues to be a limitation with these filters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Repositioning of Covered Stents: The Grip Technique

Introduction: Retrieval and repositioning of a stent deployed beyond its intended target region may be a difficult technical challenge. Materials and Methods: A balloon-mounted snare technique, a variant of the coaxial loop snare technique, is described. Results: The technique is described for the repositioning of a covered transjugular intrahepatic portosystemic shunt stent and a covered biliary stent. Conclusion: The balloon-mounted snare technique is a useful technique for retrieval of migrated stents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗