Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Power-processing unit

Power-processing unit uses AC buses (30, 32) to supply all current dependent needs such as connections (54, 56) to an ion thruster through an inductor (88) and the primary of a transformer (90), to assure limited currents to such loads. Where temperature control is also required, such as to the main discharge vaporizer heater connection (36, 38), switches (100, 102) are serially connected with inductor (96) and the primary of transformer (98). Temperature sensor (104) controls the switches (100, 102) for temperature regulation.

Wessel, Frank J.↗

Thermal design of the sample handling assembly in the sampling and caching subsystem on the Mars 2020 rover

The Mars 2020 Rover is scheduled to land on Mars on February 18, 2021. One of the primary mission objectives for the Mars 2020 Rover is to collect a set of Martian regolith samples for potential future return to Earth. Regolith and rock samples will be collected and placed into sample tubes using a coring drill, located at the end of a large Robotic Arm, on the outside of the rover. Filled sample tubes will be transferred from the outside of the Rover into the Adaptive Caching Assembly (ACA), located inside the Rover chassis, via the Bit Carousel. Once the filled sample tube is brought into the ACA, the Sample Handling Assembly (SHA) will transfer it to all of the internal processing stations of the ACA for volume assessment, sealing and finally drop-off on the Martian surface. The ACA is a volume within the rover chassis that is not temperature-controlled. Actuators inside the SHA and its End Effector (EE) must be warmed to above -55°C and -25°C, respectively, prior to use. This paper discusses the thermal design of the SHA that uses heaters and temperature sensors to warm up and maintain the temperature-sensitive arm components within temperature limits during operation. Thermal performance predictions for Mars surface operations are also presented.

Lee, Chern-Jiin↗

Model Development of Large-Scale Spacecraft Fires During the Saffire-IV Experiments

An accidental fire can pose dire consequences to crew safety and mission success. The Saffire Project aims to investigate large-scale fire behavior in microgravity in order to aid in the prediction of spacecraft fires. These series of experiments ignite solid materials within the Northrup Grumman Cygnus vehicle after it departs from a resupply mission to the International Space Station. A model of the Cygnus vehicle during the Saffire-IV experiment was developed using the commercial software PyroSim. The cargo arranged during the descent phase was used for the geometry of the model. In the model, cabin air flows into the Saffire payload while heat and combustion species flow out of the Saffire downstream through a standoff to a bed of sensors called the Far Field Diagnostic (FFD). The temperature sensors near the Saffire payload were used to determine the heat release rate at the outlet of Saffire, while the details of the combustion and stoichiometry are used to determine the species flow at the outlet. Gas measurements previously reported for the Saffire-IV experiments are compared against the simulation results and sources of error are discussed.

Modeling↗

Distributed temperature sensing inside a 19-rod bundle

The temperature field within a model of a sodium-cooled fast reactor fuel rod bundle was measured using Ø155 μm fiber optic distributed temperature sensors (DTS). The bundle consists of 19 electrically-heated rods Ø6.3 mm and 865 mm long. Working fluids were argon and air at atmospheric pressure and Reynolds numbers up to 300. A 20 m-long DTS was threaded through Ø1 mm capillaries wound around rods as wire-wraps. The sensor generated 173 measurements along each rod at 5 mm resolution for a total of 3300 data locations. A second DTS, 58 m long, was suspended between rods to provide 9300 fluid temperature measurements at 20 mm resolution. Such data density makes it possible to construct 3D maps of the temperature field that are beyond the reach of traditional sensors such as thermocouples. This is illustrated through a series of steady-state and transient tests. As a result, the work demonstrates the feasibility of mapping temperature within the close confines of a rod bundle at resolutions suitable for validation of computational fluid dynamics codes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Soil Sensors in Agriculture: From Unsustainable to Biodegradable

Commercially available bi-metallic temperature sensors have long exploited differential thermal expansions between materials to produce an actuation-induced readout from a bi-metal helix. When dispersed in agricultural land, electronic components are used to transmit information at the cost of an increased environmental footprint. This paper briefly recaps the proposed sensor, which employs a biodegradable bi-material helix composed of a polymer and metal. Proposed polymer sheetings of cellulose acetate and polylactic acid are characterized via TGA, DMA, and DSC to evaluate plasticizer content, shrinkage, and an appropriate sensor work-use range. Finally, the deflection of non-biodegradable bi-polymer strips is quantified for various combinations to determine if bi-polymer deflection is possible.

47 OTHER INSTRUMENTATION↗

A distributed temperature profiling system for vertically and laterally dense acquisition of soil and snow temperature

Abstract. Measuring soil and snow temperature with high vertical and lateral resolution is critical for advancing the predictive understanding of thermal and hydro-biogeochemical processes that govern the behavior of environmental systems. Vertically resolved soil temperature measurements enable the estimation of soil thermal regimes, frozen-/thawed-layer thickness, thermal parameters, and heat and/or water fluxes. Similarly, they can be used to capture the snow depth and the snowpack thermal parameters and fluxes. However, these measurements are challenging to acquire using conventional approaches due to their total cost, their limited vertical resolution, and their large installation footprint. This study presents the development and validation of a novel distributed temperature profiling (DTP) system that addresses these challenges. The system leverages digital temperature sensors to provide unprecedented, finely resolved depth profiles of temperature measurements with flexibility in system geometry and vertical resolution. The integrated miniaturized logger enables automated data acquisition, management, and wireless transfer. A novel calibration approach adapted to the DTP system confirms the factory-assured sensor accuracy of ±0.1 ∘C and enables improving it to ±0.015 ∘C. Numerical experiments indicate that, under normal environmental conditions, an additional error of 0.01 % in amplitude and 70 s time delay in amplitude for a diurnal period can be expected, owing to the DTP housing. We demonstrate the DTP systems capability at two field sites, one focused on understanding how snow dynamics influence mountainous water resources and the other focused on understanding how soil properties influence carbon cycling. Results indicate that the DTP system reliably captures the dynamics in snow depth and soil freezing and thawing depth, enabling advances in understanding the intensity and timing in surface processes and their impact on subsurface thermohydrological regimes. Overall, the DTP system fulfills the needs for data accuracy, minimal power consumption, and low total cost, enabling advances in the multiscale understanding of various cryospheric and hydro-biogeochemical processes.

54 ENVIRONMENTAL SCIENCES↗

Design and Operation of a Fast, Thin-Film Thermocouple Probe on a Turbine Engine

As a demonstration of technology maturation, a thin-film temperature sensor probe was fabricated and installed on a F117 turbofan engine via a borescope access port to monitor the temperature experienced in the bleed air passage of the compressor area during an engine checkout test run. To withstand the harsh conditions experienced in this environment, the sensor probe was built from high temperature materials. The thin-film thermocouple sensing elements were deposited by physical vapor deposition using pure metal elements, thus avoiding the inconsistencies of sputter-depositing particular percentages of materials to form standardized alloys commonly found in thermocouples. The sensor probe and assembly were subjected to a strict protocol of multi-axis vibrational testing as well as elevated temperature pressure testing to be qualified for this application. The thin-film thermocouple probe demonstrated a faster response than a traditional embedded thermocouple during the engine checkout run.

thermocouples↗

A High-Throughput MEMS-Based Differential Scanning Calorimeter for Direct Thermal Characterization of Antibodies

Calorimeters, which can be used for rapid thermal characterization of biomolecules, are getting intense attention in drug development. This paper presents a novel MEMS-based differential scanning calorimeter (DSC) for direct thermal characterization of protein samples. The DSC consisted of a pair of temperature sensors made by vanadium oxide (VOx) film with a temperature coefficient of resistivity of –0.025/K at 300 K, a microfluidic device with high thermal insulation (2.8 K/mW), and a Peltier heater for linear temperature scanning. The DSC exhibited high sensitivity (6.1 µV/µW), low noise (0.4 µW), high scanning rate (45 K/min), and low sample consumption volume (0.63 µL). The MEMS DSC was verified by measuring the temperature-induced denaturation of lysozyme at different pH, and then used to study the thermal stability of a monoclonal antibody (mAb), an antigen-binding fragment (Fab), and a dual variable domain immunoglobulin (DVD-Ig) at pH = 6. The results showed that lysozyme is a stable protein in the pH range of 4.0–8.0. The protein stability study revealed that the transition temperatures of the intact Fab fragment, mAb, and DVD proteins were comparable with conformational stability results obtained using conventional commercial DSC. These studies demonstrated that the MEMS DSC is an effective tool for directly understanding the thermal stability of antibodies in a high-throughput and low-cost manner compared to conventional calorimeters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PVAnalytics [SWR-20-33]

PVAnalytics inputs long term (multiple years) photovoltaic (PV) outdoor sensor data and completes autonomous quality assurance (QA) analysis on the data. Time series data from individual sensors such as electric meters, inverter outputs, irradiance, and temperature sensors are compared to physically expected outputs of these sensors under clear sky conditions based on the latitude, longitude, and orientation of the PV system. PVAnalytics outputs as QA pass or fail for each sensor, reasons determined for failure, time series flags identifying QA thresholds have been exceeded, flags for sunny days, the time zone found for the given sensor, sensor drift, time periods for passing data, and results of orientation checks.

Muller, Matthew↗

Modified Apollo cryogenic oxygen tank design

Assessment of the Apollo 13 mission indicated that some design changes to be incorporated into Apollo cryogenic oxygen storage tanks. These changes broadly fit into three categories. They were: (1) deletion of the fluid equilibration motors and redesign of heater assembly, (2) material changes for internal tank wiring and density sensor, and (3) the addition of a heater assembly temperature sensor. Development of a cryogenic oxygen tank incorporating these changes is presented.

Vanleuven, K.↗

Fiber optics for aircraft engine/inlet control

NASA programs that focus on the use of fiber optics for aircraft engine/inlet control are reviewed. Fiber optics for aircraft control is attractive because of its inherent immunity to EMI and RFI noise. Optical signals can be safely transmitted through areas that contain flammable or explosive materials. The use of optics also makes remote sensing feasible by eliminating the need for electrical wires to be connected between sensors and computers. Using low-level optical signals to control actuators is also feasible when power is generated at the actuator. Each application of fiber optics for aircraft control has different requirements for both the optical cables and the optical connectors. Sensors that measure position and speed by using slotted plates can use lossy cables and bundle connectors if data transfer is in the parallel mode. If position and speed signals are multiplexed, cable and connector requirements change. Other sensors that depend on changes in transmission through materials require dependable characteristics of both the optical cables and the optical connectors. A variety of sensor types are reviewed, including rotary position encoders, tachometers, temperature sensors, and blade tip clearance sensors for compressors and turbines. Research on a gallium arsenide photoswitch for optically switched actuators that operate at 250 C is also described.

Baumbick, R. J.↗

Spacecraft component heater control system

A heater control circuit is disclosed as being constructed in a single integrated circuit, with the integrated circuit conveniently mounted proximate to a spacecraft component requiring temperature control. Redundant heater controllers control power applied to strip heaters disposed to provide heat to a component responsive to sensed temperature from temperature sensors. Signals from these sensors are digitized and compared with a dead band temperature and set point temperature stored in memory to generate an error signal if the sensed temperature is outside the parameter stored in the memory. This error signal is utilized by a microprocessor to selectively instruct the heater controllers to apply power to the strip heaters. If necessary, the spacecraft central processor may access or interrogate the microprocessor in order to alter the set point temperature and dead band temperature range to obtain operational data relating to the operation of an integrated circuit for relaying to the ground control, or to switch off faulty components.

Bachtel, Frederick D.↗

Heat Transfer Experiments of a 1st Stage Blade Cascade for Supercritical CO2 Oxy-Combustion Turbine Application

The results of internally cooled 1st stage blade (S1B) cascade testing in a supercritical CO2 environment is presented. The turbine blade design has been previously established for the end application of an oxy-combustion turbine operating in the Allam-Fetvedt cycle with turbine inlet conditions of 305 bar and 1150°C. The internally cooled blade features leading edge (LE) region impingement cooling, mid-section ribbed serpentine passages, and a pin-finned trailing edge (TE) region before cooling ejection holes. The geometry for the tested blade cascade has a cooled central blade with un-cooled blades on either side to match flowpath areas of the actual turbine. The flowpath reuses internal components previously employed for mid-section region ribbed serpentine passage experiments that established Nusselt number enhancement ratios over a range of Reynolds numbers from 100,000-400,000. New components include flow conditioning plates upstream and downstream of the blade cascade to adequately represent the flow field and blade external heat transfer coefficient profiles for the actual turbine. The cooled central blade utilizes uniform crystal temperature sensors (UCTS) with six sensors each on the blade pressure and suction surfaces distributed radially and from LE to TE. The post-processed UCTS quantified the maximum wall temperature seen at each installed sensor location. The test procedure consisted of establishing supercritical CO2 cooling flow temperature and flow rate and maintaining it throughout the test. The flow rate aims to match that for the actual in-service turbine blade design and is maintained through an orifice restriction to keep the pressure differential between internal cooling flow and external hot flow nearly constant. For the sCO2 flow path external to the blade, temperatures were ramped throughout the test via control of the test loop’s natural gas burner heater. The maximum temperature seen was 468°C and held constant for a duration of 10 minutes at which the blade metal temperature was predicted to be at its maximum before ramping down. For the turbine blade design for service inlet conditions, external flow path computational fluid dynamics (CFD) results and an internal cooling 1-D thermal and hydraulic flow network model using experimentally validated correlations served as thermal finite element (FE) boundary conditions to predict blade metal temperatures. These predicted temperatures were subsequently utilized in a structural FE model to predict blade life ratings dictated by Haynes 282 creep strength data, having a strong dependence on temperature. The boundary conditions experienced during testing are used in the same workflow and compared to the experimental results, with the goal of validating the analysis methodology and providing insight on the uncertainty in local metal temperature predictions.

20 FOSSIL-FUELED POWER PLANTS↗

Fiber-optic bolometer with low detection limit fabricated using thermal release tape and precise laser heating

Fiber-optic bolometers (FOBs) based on a fiber-tipped silicon Fabry–Perot (FP) interferometric temperature sensor and a gold disk absorber have been shown to be an attractive alternative to conventional resistive bolometers for plasma radiation measurement in fusion devices. Either a high-finesse FP or a low-finesse FP can be used, each with trade-offs between noise performance and fabrication complexity. In this paper, we present an FOB design that overcomes these limitations by combining a low-finesse long silicon FP cavity with a large gold disk absorber to achieve enhanced sensitivity and noise performance without increasing the fabrication complexity and the time constant. We also demonstrated a fabrication method for the sensor head facilitated by thermal release tape and precise laser heating. Our FOB demonstrates a temperature resolution of 0.08 mK, a cooling time constant of 230 ms, and a noise equivalent power density of 0.015 W m −2 . This represents an eightfold improvement over previous high-finesse FOBs and 26-fold improvement over previous low-finesse FOBs with similar demodulation bandwidths and similar cooling time constants.

Fabry–Perot interferometer↗

High-Temperature Sapphire Pressure Sensors for Harsh Environments

The project aimed to develop and characterize an optical pressure sensor capable of withstanding high temperatures, up to 1000 °C. Survivability in harsh environments was enabled using sapphire for both the substrate and the optical fibers, therefore mitigating thermal expansion mismatch. Such material cannot be machined through conventional microfabrication techniques, and unique additive and subtractive methods had to be studied and implemented. Subtractive methods included laser-machining the sapphire substrate using a picosecond laser machining tool. At first, the parameters of importance were theoretically and experimentally evaluated such that the fluence, the pulse spacing, and the number of passes were found to strongly influence the laser ablation process. A simulation tool was designed to predict the final pattern when inputting a set of parameters and a profile. This model was complemented with laser ablation material physics models and Bayesian uncertainty analysis for one dimensional and three dimensional ablation processes. An additive process called thermocompression bonding was studied in order to seal the diaphragm substrate to the back cavity. At first, bonding strength using this technique was examined using the chevron-notch method that allow to determine the fracture toughness of this bond. This parameter is independent of the geometry used and therefore can be extended to other geometries used in actual sensor bonding. A theoretical and experimental study of internal damage caused by the laser micromachining of the sapphire material was carried out. The research identified enhanced strength and fracture toughness along laser ablated surfaces. This was determined using bend bar specimens and Vicker’s microindentations. Softening of the plasticity behavior (as indicated by nanoindentation experiments) was also investigated using finite deformation plasticity modeling via a contact mechanics finite element simulation. Good correlations between experiments and the model were achieved to determine material parameters that can be used in future MEMS based sensor design and modeling to minimize sensor failure loads. The enhanced strength and fracture toughness was determined to be due to compressive residual stress near laser ablated surfaces. This was confirmed through x-ray spectra taken along different crystal structure planes in combination and Bayesian uncertainty analysis. The Bayesian analysis inferred the entire residual strain tensor (six components) and the residual stress tensor. The results illustrated compressive in-plane stress was the most likely cause of enhanced strength and toughness after laser machining. Due to major equipment failures, a parallel route for fabricating the sensor was taken, using commercially available sapphire removal method (subtractive) and ceramic adhesive bonding (additive). The fully-packaged sensor utilized laser micromachining for the sapphire substrate fabrication and was comprised only of high-temperature-compatible materials. Calibration tests of the sensor in both room-temperature and high-temperature plane-wave tubes showed good linearity and consistent frequency response, in the tested frequency range. The sensor also showed good thermal stability in tests up to 300 °C, proving the fiber-optic lever and its packaging process to be a promising approach for high-temperature measurements. The calibration from 23 °C to 300 °C gave a raw sensitivity of 3.9 × 10 -7 V/Pa and a normalized sensitivity of 9.8 × 10 -8 Pa -1 which were consistent within the temperature range. The sensor had a resonance at 16.3 kHz and a flat band (±3 dB) up to 10.3 kHz. The noise floor of the sensor at 1 kHz was 316 nV/Hz 1/2 , resulting in a MDP of 0.8 Pa. Previously, diaphragm delamination due to CTE mismatch was found at 500 °C, causing packaging failure. Unfortunately high temperature validation in hot jet environment could not be made in time. In the future, it is suggested that the two sapphire substrates be bonded by thermal compression bonding with an intermediate platinum layer instead of using an alumina-based adhesive, and therefore achieve higher temperature capacity up to 1000 °C.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The effect of ultraviolet irradiation on the ultra-thin HfO{sub 2} based CO gas sensor

In this work, an effort has been made to fabricate ultrathin HfO{sub 2}/Al{sub 2}O{sub 3} sample by atomic layer deposition method for the fast detection of CO gas at room temperature. The effect of the operating temperature and the UV light on the gas sensing characteristics has been studied. We investigated the optimum operating temperature for the sample by sensing 25 ppm CO and CO{sub 2} gases from room temperature to 150 °C for 10 °C steps. The maximum response was obtained at 150 °C for both gases in the measurement temperature range. Also, the photoresponse measurements clearly show the effect of UV light on the sample. At room temperature, sensor showed superior response (14%) for 5 ppm CO gas. The response time of sensor is 6 s to 5 ppm CO gas concentration. The ultrathin HfO{sub 2} based sample shows acceptable gas sensitivity for 5 ppm CO gas at room temperature under UV light irradiation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced temperature sensing based on sub-threshold nonlinear spectra of one-dimensional photonic crystal with a Kerr defect layer

A new method to achieve highly sensitive temperature sensing is proposed based on the nonlinear spectral properties of a one-dimensional photonic crystal (1DPC) composed of temperature-sensitive materials with a Kerr defect layer. The sensitivity can be two orders of magnitude higher than that of the corresponding linear 1DPC structure. The sensitivity and measuring range can be precisely tuned. These properties favor the fabrication of a versatile temperature sensor with switchable fine and coarse tuning functions. This principle of nonlinear temperature sensing can also be extended to other kinds of spectrum-based sensors to obtain higher performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Temperature Thick Film Sensor Development Based on Refractory Oxide Semiconductors

Solid-state, high-temperature sensing devices are required for accurate temperature, strain/stress, and failure monitoring for a range of advanced manufacturing, transportation, and military applications. High temperature conditions limit sensing strategies, where typically traditional metal and semiconductor materials are unstable, and the sensing options are limited to optical spectroscopy methods. In addition, strategies to embed the sensors directly within active components and protective thermal refractory are of interest that permit near-environment sensing which is not possible with the traditional electronic materials and components. Rare-earth chromite semiconductors exhibit some properties of interest for high temperature sensing technologies, such as: high microstructure and chemical stability, relatively high electronic conductivity at high temperatures, and relative thermal expansion coefficient matching to refractory thermal protective insulation (such as high-zirconia and -alumina ceramics). In this work, n-type and p-type doped lanthanum chromites compositions were computationally modelled and prepared, and the electrical, thermoelectric, and thermomechanical properties were measured for the obtained material systems. A few compositions were then processed into thick film health and temperature sensors and tested at high temperatures. To establish relative stability under harsh environment conditions, post- mortem microstructure and chemical composition was characterized after extended and cycle testing at high temperatures.

20 FOSSIL-FUELED POWER PLANTS↗