At least 469 records · Page 26

An on-line expert system for diagnosing environmentally induced spacecraft anomalies using CLIPS

A new rule-based, expert system for diagnosing spacecraft anomalies is under development. The knowledge base consists of over two-hundred rules and provide links to historical and environmental databases. Environmental causes considered are bulk charging, single event upsets (SEU), surface charging, and total radiation dose. The system's driver translates forward chaining rules into a backward chaining sequence, prompting the user for information pertinent to the causes considered. The use of heuristics frees the user from searching through large amounts of irrelevant information (varying degrees of confidence in an answer) or 'unknown' to any question. The expert system not only provides scientists with needed risk analysis and confidence estimates not available in standard numerical models or databases, but it is also an effective learning tool. In addition, the architecture of the expert system allows easy additions to the knowledge base and the database. For example, new frames concerning orbital debris and ionospheric scintillation are being considered. The system currently runs on a MicroVAX and uses the C Language Integrated Production System (CLIPS).

Lauriente, Michael↗

Development and Evaluation of Embrittlement Resistant Alloys for Advanced LWR Cladding

The primary challenge preventing the deployment of reactor designs that leverage wrought FeCrAl as an advanced light-water reactor (LWR) cladding is irradiation hardening and embrittlement. Wrought FeCrAl alloys experience a loss of post-irradiation ductility and fracture toughness under low-temperature neutron irradiation (< 350°C) resulting from the combined effects of dislocation loop formation and the irradiation-enhanced precipitation of Cr-rich alpha-prime precipitates throughout the microstructure. Over the past decade, significant improvements in our understanding regarding the effect of Cr and Al content have been enabled through neutron irradiations, but even optimized wrought alloys such as C26M remain vulnerable to brittle failure during storage, transportation, and handling following irradiation. This report summarizes multiple irradiation campaigns initiated over the past 7 years and provides recent insights into the effect of (1) minor alloying composition, (2) alloy processing strategy, (3) crystal structure, and (4) the use of advanced oxide dispersion strengthened (ODS) alloys. The first irradiation campaign irradiated body-centered cubic FeCrAl alloy C26M with and without elements such as Mo and Y. It also included face-centered cubic alumina-forming austenitic (AFA) alloys that have a steeper neutronic penalty but that have far superior high-temperature strength than wrought FeCrAl. Finally, this campaign compared conventional wrought C26M with the same material produced using modern powder metallurgical hotisostatic pressing (PM-HIP). The second irradiation campaign, initiated in 2018, irradiated wrought and FeCrAl-ODS materials up to 50 dpa to assess their irradiation resistance to high-doses. The results of this work indicate that wrought C26M suffers significant degradation following neutron irradiation at LWR-relevant temperatures regardless of Mo and Y content. The PM-HIP variant appears to be more resilient to irradiation-induced ductility loss in comparison with wrought variants but still loses almost all ductility by 8 dpa. Notably, the AFAs retained at least 5% total elongation after irradiation at the same dose and temperature condition, although additional deterioration may be expected at higher fluence levels. FeCrAl-ODS materials show the greatest promise as a transformative longer-term accident-tolerant fuel (LT-ATF) cladding material. The extruded 106ZY10C alloy retained 10% total elongation after 16 dpa irradiation and retained 8% total elongation after 50 dpa. Additional challenges with FeCrAl-ODS alloys also remain, including optimization of end cap joining methodologies, enhancement of fracture toughness, scaling production to prove economic viability, and optimizing post-pilger heat treatments to maximize ductility and irradiation resistance. This series of irradiations demonstrates the efficacy of the LWR testbed available within the United States for the rapid irradiation and down-selection of LT-ATF candidates. As the country rapidly accelerates its timeline for the deployment of advanced reactor concepts, the effective utilization of the High Flux Isotope Reactor for separate-effects style irradiations should continue to be prioritized to answer the final questions pertaining to LT-ATF candidates necessary for the deployment of advanced boiling water reactors and small modular reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of continuous gamma-ray exposure on performance of learned tasks and effect of subsequent fractionated exposures on blood-forming tissue

Sixteen monkeys trained to perform continuous and discrete-avoidance and fixed-ratio tasks with visual and auditory cues were performance-tested before, during, and after 10-day gamma-ray exposures totaling 0, 500, 750, and 1000 rads. Approximately 14 months after the performance-test exposures, surviving animals were exposed to 100-rad gamma-ray fractions at 56-day intervals to observe injury and recovery patterns of blood-forming tissues. The fixed-ratio, food-reward task performance showed a transient decline in all dose groups within 24 hours of the start of gamma-ray exposure, followed by recovery to normal food-consumption levels within 48 to 72 hours. Avoidance tasks were performed successfully by all groups during the 10-day exposure, but reaction times of the two higher dose-rate groups in which animals received 3 and 4 rads per hour or total doses of 750 and 1000 rads, respectively, were somewhat slower.

Spalding, J. F.↗

High-density Boron Nitride Nanotube Composites via Surfactant-stabilized Lyotropic Liquid Crystals for Enhanced Space Radiation Shielding

Despite significant technological advancements in space exploration, human space travel and colonization remain limited by the health risks associated with space radiation. Boron nitride nanotubes (BNNTs) have been proposed as an advanced material for space applications due to their high specific strength and efficient radiation shielding capabilities. However, the practical implementation of BNNTs has been slow, primarily due to technological challenges in fabricating structural materials incorporating BNNTs. In this study, a method is presented for fabricating high-density BNNT films that are mechanically robust, exhibit high thermal conductivity, and effectively attenuate space radiation. The key advancement enabling high-density BNNT films is the successful preparation of BNNT liquid crystals (LCs), achieved through the strategic use of a commercial dodecylbenzenesulfonic acid surfactant. This surfactant ensures exceptional BNNT stability in aqueous dispersion, even at concentrations exceeding the LC phase transition threshold. Simulations, estimating the equivalent radiation dose to the human body in space, indicate that a high-density BNNT film with a surface density of 50 g cm−2 reduces the total dose equivalent rate by 56% compared to zero shielding. This enhancement would allow astronauts to extend their mission duration on the lunar surface by a factor of two.

Young-Kyeong Kim↗

Rejoining and misrejoining of radiation-induced chromatin breaks. I. experiments with human lymphocytes

Fluorescence in situ hybridization with a composite probe for human chromosome 4 and a probe that stained all centromeres was used to study gamma-ray induced breakage, rejoining and misrejoining in prematurely condensed chromosomes in human lymphocytes. Dose-response curves for the induction of all types of aberrations in prematurely condensed human chromosomes 4 were determined immediately after irradiation and after 8 h postirradiation incubation. In addition, aberrations were measured after various incubation times from 0 to 18 h after a dose of 7 Gy. Unrejoined chromosome breaks were the most frequent type of aberration observed immediately after irradiation. Approximately 15% of total aberrations observed were chromosome exchanges. After 8 h postirradiation incubation, the frequency of breaks in prematurely condensed chromosomes declined to about 20% of the initial value, and chromosomal exchanges became the most frequent aberration. Results of metaphase analysis were similar to those for prematurely condensed chromosomes after 8 h incubation with the exception that a significantly lower frequency of fragments was observed. Symmetrical and asymmetrical interchanges were found at similar frequencies at all doses. No complex exchanges were observed in lymphocyte chromosomes immediately after exposure. They accounted for about 1% of total exchanges in metaphase chromosomes at doses <3 Gy and about 14% at 7 Gy. Incomplete exchanges amounted to approximately 15% of total exchanges at all doses. The kinetics of break rejoining was exponential, and the frequency of exchanges increased with kinetics similar to that observed for the rejoining of the breaks. This increase in the total exchanges as a function of the time between irradiation and fusion was due to a rapid increase in reciprocal interchanges, and a slower increase in complex exchanges; the frequency of incomplete exchanges increased initially, then decreased with prolonged incubation to the level observed in metaphase. It is concluded that the formation of each kind of chromosome aberrations follows different kinetics.

NASA Discipline Radiation Health↗

Performance evaluation of pulse shape discrimination capable organic scintillators for space applications

Scintillators with pulse-shape discrimination (PSD) capability are of great interest to many fields in the scientific community. The ability to discern a gamma ray from a neutron using PSD varies between different types of scintillator materials and dopants. Here a new generation of organic scintillator materials with PSD capability were studied to determine their radiation hardness to neutron and gamma-ray radiation. The PSD capability, average pulse shapes, and light output of four types of organic scintillator were characterized before and after neutron and gamma-ray irradiation. The main goal of this investigation is to study the effects of long-term irradiation that may be experienced in space applications on the light output and particle discriminating capabilities of each material. EJ-270, EJ-276, organic glass, and Stilbene were tested. Damage due to neutron irradiation (displacement damage) was not observed in any of the scintillators up to 2.56 x 10 11 n/cm 2 , except for Stilbene which showed a small (12%) decrease in light output. All scintillators presented some light output reduction after gamma-ray irradiation (total ionizing dose), with reductions of 17% (EJ-276 and OGS), 32% (EJ-270), and 42% (Stilbene) observed immediately after 100 kRad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of X-ray Irradiation and Carnauba Wax Coating on Quality of Lime (Citrus latifolia Tan.) Fruit

The quality of Persian (Tahiti) lime (Citrus latifoliaTan.) fruit was determined following coating with carnauba wax and X-ray irradiation at doses suitable for disinfestation of quarantine pests. Fruit with or without carnauba wax coating were treated with irradiation doses of 0, 150, 300, or 450 Gy, and stored for 14 days at 13 °C and 6 days at 20 °C to simulate commercial transportation and marketing conditions from Hawaii to the continental United States. The fruit color, weight loss, total soluble solids (TSS) content, and titratable acidity (TA) were analyzed at 7, 14, and 14 + 6 days post irradiation. Wax coating significantly delayed fruit peel discoloration, and reduced fruit weight loss by more than 7% compared with the unwaxed controls. Irradiation did not affectΔEof the peel for coated fruit at day 14 + 6. Irradiation with or without coating did not affectΔEof flesh color, weight loss, TSS content, or TA. Wax coating combined with irradiation treatment of limes at doses ≤450 Gy ensured marketable visual quality and chemical composition while providing quarantine security.

Agriculture↗

Hardness Assurance and Testing Techniques for High Resolution (12- to 16-bit) Analog-to-Digital Converters

Discussed are hardness assurance and testing techniques to test and evaluate total dose radiation degradation of high resolution A/D converters. Because high-speed, high-resolution converters are critical parts in a digital signal processing or data acquisition system, the evaluation of performance in the early design phase is very important. Converters from three manufacturers are evaluated.

Analog-to-Digital↗

A machine independent expert system for diagnosing environmentally induced spacecraft anomalies

A new rule-based, machine independent analytical tool for diagnosing spacecraft anomalies, the EnviroNET expert system, was developed. Expert systems provide an effective method for storing knowledge, allow computers to sift through large amounts of data pinpointing significant parts, and most importantly, use heuristics in addition to algorithms which allow approximate reasoning and inference, and the ability to attack problems not rigidly defines. The EviroNET expert system knowledge base currently contains over two hundred rules, and links to databases which include past environmental data, satellite data, and previous known anomalies. The environmental causes considered are bulk charging, single event upsets (SEU), surface charging, and total radiation dose.

Rolincik, Mark J.↗

Survival of bacterial isolates exposed to simulated Jovian trapped radiation belt electrons and solar wind protons

With missions to Jupiter, the spacecraft will be exposed for extended durations to solar wind radiation and the Jovian trapped radiation belt. This study is designed to determine the effect of these radiation environments on spacecraft bacterial isolates. The information can be used in the probability of contamination analysis for these missions. A bacterial subpopulation from Mariner Mars 1971 spacecraft (nine spore-forming and three non-spore-forming isolates) plus two comparative organisms, Staphylococcus epidermidis ATCC 17917 and a strain of Bacillus subtilis var. niger, were exposed to 2, 12, and 25 MeV electrons at different doses with simultaneous exposure to a vacuum of 1.3 x 10(-4) N m-2 at 20 and -20 degrees C. The radioresistance of the subpopulation was dependent on the isolate, dose and energy of electrons. Temperature affected the radioresistance of only the spore-forming isolates. Survival data indicated that spores were reduced approximately 1 log/1500 J kg-1 (10 J kg-1=1 krad), while non-spore-forming isolates (micrococci) were reduced 1.5-2 logs/1500 J kg-1 with the exception of an apparent radioresistant isolate whose resistance approached that of the spores. The subpopulation was found to be less resistant to lower energy than to higher energy electrons. The bacterial isolates were exposed to 3 keV protons under the same conditions as the electrons with a total fluence of 1.5 x 10(13) p cm-2 and a dose rate of 8.6 x 10(9) p cm-2 s-1. The results showed that only 20% of S. epidermidis and 45% of B. subtilis populations survived exposure to the 3 keV protons, while the mean survival of the spacecraft subpopulation was 45% with a range from 31.8% (non-spore-former) to 64.8% (non-spore-former). No significant difference existed between spore-forming and non-spore-forming isolates.

Electrons↗

A 100-Mrad (Si) JFET-based Sensing and Communications System for Extreme Nuclear Instrumentation Environments

Dry cask storage is one of two storage methods approved by the U.S. Nuclear Regulatory Commission for spent fuel after removal from reactor cores. Dry casks consist of a stainless steel canister enclosed in a concrete overpack to contain the hazardous radioactive spent fuel rods and provide radiation shielding. Monitoring spent fuel storage casks is desired to ensure the safe containment of the enclosed spent fuel, but is very difficult due to the related harsh temperature and radiation environment. The sensors and associated electronics to monitor temperature, pressure, and/or radiation need to survive high temperatures and radiation doses for extended time periods. For this reason, there is a severe need for radiation-hardened electrical systems that survive well beyond the existing capabilities of commercially available radiation-rated electronic components, which have primarily been developed for space applications. Junction-gate field-effect transistor (JFET) devices are inherently radiation hardened [exceeding 100 Mrad (Si)]. Additionally, when JFETs are used as building blocks for sensing and communication electronics (i.e., oscillators, amplifiers, filters, and mixers), inherently radiation-hardened circuits can be achieved. To this end, JFET-based radiation-hardened electronics interfacing with cask-embedded sensors capable of driving modulated sensor signals through a stainless steel barrier were designed and tested at a dose rate of approximately 500 krad/h (Si) to beyond a 200-Mrad (Si) total ionizing dose. After 200 Mrad (Si), the sensor and communication circuit signals were correctly decoded at the receiver despite oscillator drift. The results from this experiment demonstrate the potential for creating more complex radiation-hardened JFET-based electrical systems for nuclear environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary results of radiation measurements on EURECA

The eleven-month duration of the EURECA mission allows long term radiation effects to be studied similarly to those of the Long Duration Exposure Facility (LDEF). Basic data can be generated for projections of crew doses and electronic and computer reliability on spacecraft missions. A radiation experiment has been designed for EURECA which uses passive integrating detectors to measure average radiation levels. The components include a Trackoscope, which employs fourteen plastic nuclear track detector (PNTD) stacks to measure the angular dependence of LET (greater than or equal to 6 keV/microns) radiation. Also included are TLD's for total absorbed doses, thermal/resonance neutron detectors (TRND's) for low energy neutron fluences and a thick PNTD stack for depth dependence measurements. LET spectra are derived from the PNTD measurements. Preliminary TLD results from seven levels within the detector array show that integrated doses inside the flight canister varied from 18.8 plus or minus 0.6 cGy to 38.9 plus or minus 1.2 cGy. The TLD's oriented toward the least shielded direction averaged 53 percent higher in dose than those oriented away from the least shielded direction (minimum shielding toward the least shielded direction varied from 1.13 to 7.9 g/cm(exp 2), Al equivalent). The maximum dose rate on EURECA (1.16 mGy/day) was 37 percent of the maximum measured on LDEF and dose rates at all depths were less than measured on LDEF. The shielding external to the flight canister covered a greater solid angle about the canister than in the LDEF experiments.

Benton, E. V.↗

Comparison of a Probabilistic TID Hardness Assurance Method to Military Standards

The rapid evolution of electronics has heralded countless benefits to humanity, enabling increases in computing power while decreasing costs. However, the constantly changing semiconductor device landscape proves to be an immense challenge for the reliability community, especially for those concerned with radiation effects on microelectronics. Changes in device manufacturing, from device structure to processing steps, may and often do change the way the device responds to radiation. While radiation hardened parts are not as much of a reliability concern, they also lag behind commercial off-the-shelf, or COTS, parts in terms of computing capabilities, some by over a decade. Many missions may have no choice but to utilize COTS. As such, these missions need to ensure their parts are reliable in the face of total ionizing dose (TID). However, part and testing facility costs limit the amount of testing possible.

Chloe Champagne↗

Preliminary results of radiation measurements on EURECA

The eleven-month duration of the EURECA mission allows long-term radiation effects to be studied similarly to those of the Long Duration Exposure Facility (LDEF). Basic data can be generated for projections to crew doses and electronic and computer reliability on spacecraft missions. A radiation experiment has been designed for EURECA which uses passive integrating detectors to measure average radiation levels. The components include a Trackoscope, which employs fourteen plastic nuclear track detector (PNTD) stacks to measure the angular dependence of high LET (greater than or equal to 6 keV/micro m) radiation. Also included are TLD's for total absorbed doses, thermal/resonance neutron detectors (TRND's) for low energy neutron fluences and a thick PNTD stack for depth dependence measurements. LET spectra are derived from the PNTD measurements. Preliminary TLD results from seven levels within the detector array show that integrated does inside the flight canister varied from 18.8 +/- 0.6 cGy to 38.9 +/- 1.2 cGy. The TLD's oriented toward the least shielded direction averaged 53% higher in dose than those oriented away from the least shielded direction (minimum shielding toward the least shielded direction varied from 1.13 to 7.9 g/cm(exp 2), Al equivalent). The maximum dose rate on EURECA (1.16 mGy/day) was 37% of the maximum measured on LDEF and dose rates at all depths were less than measured on LDEF. The shielding external to the flight canister covered a greater solid angle about the canister than the LDEF experiments.

Benton, E. V.↗

Effects of methiothepin on changes in brain serotonin release induced by repeated administration of high doses of anorectic serotoninergic drugs

We previously observed, using in vivo microdialysis, that the potassium-evoked release of frontocortical serotonin (5-HT) is suppressed after rats receive high doses (30 mg/kg, i.p., daily for 3 days) of fluoxetine, a selective blocker of 5-HT reuptake. We now describe similar impairments in 5-HT release after repeated administration of two other 5-HT uptake blockers, zimelidine and sertraline (both at 20 mg/kg, i.p. for 3 days) as well as after dexfenfluramine (7.5 mg/kg, i.p. daily for 3 days), a drug which both releases 5-HT and blocks its reuptake. Doses of these indirect serotonin agonists were about 4-6 times the drug's ED50 in producing anorexia, a serotonin-related behavior. In addition, methiothepin (20 microM), a non-selective receptor antagonist, locally perfused through the dialysis probe 24 h after the last drug injection, enhanced K(+)-evoked release of 5-HT at serotoninergic nerve terminals markedly in control rats and slightly in rats treated with high doses of dexfenfluramine or fluoxetine. On the other hand, pretreatment with methiothepin (10 mg/kg, i.p.) one hour before each of the daily doses of fluoxetine or dexfenfluramine given for 3 days, totally prevented the decrease in basal and K(+)-evoked release of 5-HT. Finally, when methiothepin was injected systemically the day before the first of 3 daily injections of dexfenfluramine, it partially attenuated the long-term depletion of brain 5-HT and 5-HIAA levels induced by repeated administration of high doses of dexfenfluramine. These data suggest that drugs which bring about the prolonged blockade of 5-HT reuptake - such as dexfenfluramine and fluoxetine - can, by causing prolonged increases in intrasynaptic 5-HT levels as measured by in vivo microdialysis, produce receptor-mediated long-term changes in the processes controlling serotonin levels and dynamics.

NASA Discipline Regulatory Physiology↗

Exposure to an environmental mixture of polycyclic aromatic hydrocarbons induces hepatic cytochrome P450 enzymes in mice

Cytochrome P450 enzymes (CYPs) play an important role in bioactivating or detoxifying polycyclic aromatic hydrocarbons (PAHs), common environmental contaminants. While it is widely accepted that exposure to PAHs induces CYPs, effectively increasing rates of xenobiotic metabolism, dose- and time-response patterns of CYP induction are not well known. In order to better understand dose- and time-response relationships of individual CYPs following induction, we exposed B6129SF1/J mice to single or repeated doses (2-180 µmol/kg/d) of benzo[a]pyrene (BaP) or Supermix-10, a mixture of the top 10 most abundant PAHs found at the Portland Harbor Superfund Site. In hepatic microsomes from exposed mice, we measured amounts of active CYPs using activity-based protein profiling and total CYP expression using global proteomics. We observed rapid Cyp1a1 induction after 6 hr at the lowest PAH exposures and broad induction of many CYPs after 3 daily PAH doses at 72 hr following the first dose. Using samples displaying Cyp1a1 induction, we observed significantly higher metabolic affinity for BaP metabolism (Km reduced 3-fold), 3-fold higher intrinsic clearance, but no changes to the Vmax. Mice dosed with the highest PAH exposures exhibited 1.7 to 5-fold higher intrinsic clearance rates for BaP compared to controls and higher Vmax values indicating greater amounts of enzymes capable of metabolizing BaP. This study demonstrates exposure to PAHs found at Superfund Sites induces enzymes in dose- and time-dependent patterns in mice. Accounting for specific changes in enzyme profiles, and relative rates of PAH bioactivation and detoxification, and resulting risk will help translate internal dosimetry of animal models to humans and improve risk assessments of PAHs at Superfund sites.

Stoddard, Ethan G.↗

Ptychographic atomic electron tomography: Towards three-dimensional imaging of individual light atoms in materials

Through numerical simulations, we demonstrate the combination of ptychography and atomic electron tomography as an effective method for low dose imaging of individual low-Z atoms in three dimensions. After generating noisy diffraction patterns with multislice simulations of an aberration-corrected scanning transmission electron microscope through a 5-nm zinc-oxide nanoparticle, we have achieved three-dimensional (3D) imaging of individual zinc and oxygen atoms and their defects by performing tomography on ptychographic projections. The methodology has also been simulated in 2D materials, resolving individual sulfur atoms in vertical WS 2 /WSe 2 van der Waals heterostructure with a low total electron dose where annular-dark-field images fail to resolve. Overall, we envision that the development of this method could be instrumental in studying the precise 3D atomic structures of radiation sensitive systems and low-Z atomic structures such as 2D heterostructures, catalysts, functional oxides, and glasses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects of Daily Centrifugation on Segmental Fluid Distribution in Bed-rested Subjects

The effect of daily centrifugation on segmental fluid distribution have been studied during 21 days of 6 degree head down bedrest. One group (N=7) underwent no countermeasure while the other (N=8) received a daily, one hour, dose (2.5 gz at the foot, decreasing to 1.0 gz at the heart) of artificial gravity (AG) training on the Johnson Space Center short radius centrifuge. Fluid shifts of thoracic(VTO), abdominal (VAB), thigh (VTH), and calf (VCA) regions were measured by the tetrapolar segmental body impedance technique. Untrained subjects reduced their total volume from 18.9 plus or minus 0.5L to 17.9 plus or minus 0.9L (MN plus or minus SE, P less than 0.05) while trained subjects maintained their total volume. In untrained, control, subjects after bed rest, there was a trend toward reduced volume in all segments, with significant reductions in thigh and calf (fig, P less than 0.05). Trained subjects maintained volume in all segments. Our data indicate that artificial gravity treatment counteracts bed rest-induced hypovolemia.

Diedrich, Andre↗