Evaluation of microalgae cultivation at air-CO 2 equilibrium pH for improving carbon utilization efficiency

Microalgae are often cultivated at near-neutral pH to optimize growth. However, this results in significant CO 2 loss through outgassing in open-pond cultivation systems, leading to low CO 2 utilization efficiency and higher biomass production costs. One potential solution is algal cultivation at air-CO 2 equilibrium pH, which minimizes CO 2 outgassing but may inhibit growth due to stresses at higher pH levels. In this study, we evaluated the viability of this approach by growing Picochlorum celeri and Tetraselmis striata under outdoor relevant conditions at equilibrium pH. Compared to pH 7 cultures, biomass productivity declined by 35 % for P. celeri and 57 % for T. striata. Although CO 2 outgassing could be minimized, the significant loss in productivity led to a higher overall minimum biomass selling price (MBSP). Increased ammonia toxicity at the higher pH was found to be one of the growth-limiting factors and was mitigated by reducing ammonium fertilizer concentration. This adjustment resulted in a more moderate productivity decline of 13 % (instead of 35 %) for T. striata, and consequently, a lower MBSP was achieved. These findings suggest that equilibrium pH cultivation may be a viable method for reducing CO 2 loss without significantly compromising biomass productivity. Depending on the strain, strategies to mitigate stressors, such as ammonia toxicity, may be necessary.

09 BIOMASS FUELS↗

Time Matters: A Survival Analysis of Public Electric Vehicle Charging Infrastructure Utilization

The rapid adoption of plug-in electric vehicles (PEVs) places significant demands on public charging infrastructure, making it critical to understand and optimize charger utilization. This study provides one of the most comprehensive analyses of charging behavior to date by applying a survival analysis to a dataset of nearly 16 million level 2 (L2) and direct current (DC) fast charger sessions across the United States from 2017 to 2022. Using Kaplan-Meier curves and log rank tests, our analysis reveals statistically significant and distinct duration patterns influenced by charger type, time of day, and day of the week. We find that L2 charging sessions exhibit high variability tied to venue type, whereas DC sessions are more uniform, typically lasting 30-45 min. This study introduces the operational efficiency score (OES), a metric for standardizing the performance evaluation of charging stations. Our findings offer actionable insights for optimizing charger deployment, developing dynamic pricing strategies to reduce vehicle dwell time, and improving load management for grid operators, ultimately enhancing the efficiency and availability of public charging infrastructure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utility-Scale Solar, 2024 Edition: Analysis of Empirical Plant-level Data from U.S. Ground-mounted PV, PV+battery, and CSP Plants (exceeding 5 MWAC)

Berkeley Labs "Utility-Scale Solar", 2024 Edition presents analysis of empirical plant-level data from the U.S. fleet of ground-mounted photovoltaic (PV), PV+battery, and concentrating solar-thermal power (CSP) plants with capacities exceeding 5 MWAC. While focused on key developments in 2023, this report explores trends in deployment, technology, capital and operating costs, capacity factors, the levelized cost of solar energy (LCOE), power purchase agreement (PPA) prices, wholesale market value, net value, and interconnection queue data.

analysis↗

Technoeconomic and Emissions Analysis of the Hybrid Redox Process for the Production of Acetic Acid with CO 2 Utilization

The production of oxygenated hydrocarbons, such as acetic acid, using captured CO 2 is a promising pathway to reduce greenhouse gas emissions in the chemical industry. The use of a chemical looping‐based hybrid redox process (HRP) is proposed to convert CO 2 and natural gas into separate CO and syngas streams that can be used to produce various commodity oxygenates, while allowing the beneficial utilization of captured CO 2 . Here, a detailed technoeconomic analysis of HRP applied to the production of acetic acid is presented. Emissions and energy analyses show the ability of HRP to lower the CO 2 emissions for acetic acid synthesis by 74% compared to a conventional steam and autothermal reforming route. HRP also offers a potential 34% reduction in capital costs. Compared to a dry reforming based acetic acid production route, HRP has the potential for significantly lower costs. If integrated with a low carbon energy source, HRP has the potential to achieve a negative emission of greenhouse gas (‐0.50 kg CO 2 per kg acetic acid).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-facility analysis using metered power data to quantify MRI energy use and utility bill costs across scanner operating modes

This study quantifies the energy consumption of magnetic resonance imaging (MRI) scanners across discrete operating modes during routine clinical workflows, based solely on electrical power measurements. Although previous studies have investigated MRI energy consumption within single hospitals or specific clinical settings, this research provides a broader and more systematic analysis. Researchers analyzed electrical power data and applied a previously developed semi-automatic method for identifying MRI operating modes using load duration curves for 20 MRI scanners across four different U.S. healthcare facilities, encompassing outpatient, inpatient, and mixed-use clinical settings. A key innovation is the inclusion of localized hourly utility rates to estimate costs, a parameter absent in prior literature. Key findings indicate significant variability in energy and cost profiles between weekdays and weekends. Scanner characteristics, including magnet strength, manufacturer, vintage, location, and clinical setting, influenced average daily energy consumption and power thresholds for operating modes. Notably, the clinical setting of a scanner predominantly determines its energy use. For example, the scanners in outpatient facilities consumed more energy. The breakdown of energy usage and costs by operating modes showed scanners spend between 61% and 93% of their time in nonproductive modes, with one outlier spending 34%. Average daily energy use for the scanners in the study ranged from 160 to 1069 kWh, with energy costs ranging from $\$$9 to $\$$149. This study uses an existing framework to quantify MRI energy behavior, leading to insights that can enable improved performance and cost savings across different healthcare environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

District heating utilizing waste heat of a data center: High-temperature heat pumps

Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantum utility-scale error mitigation for quantum quench dynamics in Heisenberg spin chains

Here, we implement a quantum error mitigation method termed self-mitigation, which is comparable to zero-noise extrapolation, at large scales to achieve quantum utility on near-term, noisy quantum computers. We investigate the effectiveness of several quantum error mitigation strategies, including self-mitigation, by simulating quantum quench dynamics for Heisenberg spin chains with system sizes up to 104 qubits using IBM quantum processors. In particular, we discuss the limitations of zero-noise extrapolation and the advantages offered by self-mitigation at large scales. The self-mitigation method demonstrates stable accuracy with large systems of 104 qubits comprising more than 3,000 CNOT gates. Also, we combine the discussed quantum error mitigation methods with practical entanglement entropy measuring methods, and it shows a good agreement with the theoretical estimation. Our study illustrates the usefulness of near-term noisy quantum hardware in examining the quantum quench dynamics of many-body systems at large scales and lays the groundwork for surpassing classical simulations with quantum methods prior to the development of fault-tolerant quantum computers.

97 MATHEMATICS AND COMPUTING↗

Trust Model Utilization for Energy Grid Communication

The internet information that is used by the Energy Grid of Things requires both preventative security measures as well as surveillance measures. The preventative security measures include certificates, encryption, and all of the basic security protocols as defined by published standards. The surveillance measures include monitoring information flow activities and evaluating these messages for indications of potential security attacks. We describe in this paper the utilization of a Distributed Trust Model that was developed specifically for monitoring communication within an Energy Grid of Things. The goal for the Distributed Trust Models is to provide a level of aggregate trust that a Distributed Energy Resource Management System can meet its grid service obligations, as opposed to a detailed individual Distributed Energy Resources assessment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nannochloropsis oceanica IMET1 and its bacterial symbionts for carbon capture, utilization, and storage: biomass and calcium carbonate production under high pH and high alkalinity

ABSTRACT To combat the increasing levels of carbon dioxide (CO 2 ) released from the combustion of fossil fuels, microalgae have emerged as a promising strategy for biological carbon capture, utilization, and storage. This study used a marine microalgal strain, Nannochloropsis oceanica IMET1, which thrives in high CO 2 concentrations. A high-pH, high-alkalinity culture was designed for CO 2 capture through algal biomass production as well as permanent sequestration through calcium carbonate (CaCO 3 ) precipitation. This was accomplished by timed pH elevation and the addition of sodium bicarbonate to cultures of N. oceanica grown at lab scale (1 L) and pilot scale (500 L) with 10% and 5% CO 2 , respectively. Our data showed that 0.02 M NaHCO 3 promoted algal growth and that sparging cultures with ambient air after 12 days raised pH and created favorable CaCO 3 formation conditions. At the 1 L scale, we reached 1.52 g L −1 biomass after 12 days and an extra 9.3% CO 2 was captured in the form of CaCO 3 precipitates. At the 500 L pilot scale, an extra 60% CO 2 was captured (Day 40) with a maximum CO 2 capture rate of 63.2 g m −2 day −1 (Day 35). Bacterial communities associated with the microalgae were dominated by two novel Patescibacteria. Functional analysis revealed that genes for several plant growth-promotion traits (PGPTs) were enriched within this group. The microalgal-bacterial coculture system offers advantages for enhanced carbon mitigation through biomass production and simultaneous precipitation of recalcitrant CaCO 3 for long-term CO 2 storage. IMPORTANCE Capturing carbon dioxide (CO 2 ) released from fossil fuel combustion is of the utmost importance as the impacts of climate change continue to worsen. Microalgae can remove CO 2 through their natural photosynthetic pathways and are additionally able to convert CO 2 into a stable, recalcitrant form as calcium carbonate (CaCO 3 ). We demonstrate that microalgae-based carbon capture systems can be greatly improved with high pH and high alkalinity by providing optimal conditions for carbonate precipitation. Our results with the microalga, Nannochloropsis oceanica strain IMET1, show an extra 9.3% CO 2 captured as CaCO 3 at the 1 L scale and an extra 60% CO 2 captured at the 500 L (pilot) scale. Our optimized system provides a novel approach to capture CO 2 through two mechanisms: (i) as organic carbon within microalgal biomass and (ii) as inorganic carbon stored permanently in the form of CaCO 3.

20 FOSSIL-FUELED POWER PLANTS↗

MARVEL Utilization Plan

This report provides a high-level overview of the utilization plan for the MARVEL microreactor. The main focus is on discussing testing and application-demonstration opportunities that leverage the reactor. With the reactor rapidly progressing towards demonstration, along with the short (2- year) operational window, it was deemed critical to establish a basis for how stakeholders can engage with the program and leverage the reactor as a testbed. This report discusses potential opportunities to use MARVEL, leveraging from data and design access to testing novel controls, and novel nuclear-electric and nuclear-heat applications. It provides guidance for interested stakeholders on potential funding opportunities that can be pursued to support tests during the operational lifetime of the reactor. The report discusses the recommended strategy for outreach and the organizational structure to review and select projects for participation. Interested stakeholders are encouraged to fill out a questionnaire on how they could leverage MAVEL at this link: https://qfreeaccountssjc1.az1.qualtrics.com/jfe/form/SV_72InKjSEz54Q2j4 It is important to emphasize that this is intended to be a living document (updated annually or as needed) with revisions issued as the MARVEL demonstration timeline evolves. Similarly, the framework for engagement is subject to change as the project progresses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Technical and Economic Screening for Potential of Distributed Energy Resource Integration at Chervonohrad Water Utility in Ukraine

In this report, the authors present a preliminary techno-economic screening for distributed renewable energy for Chervonohrad Vodokanal, the water utility in Chervonohrad, Ukraine. The screening estimates the technical potential and economics of integrating solar photovoltaics (PV) and battery energy storage systems (BESS) at Chervonohrad Vodokanal water pumping stations, Pravda, Bendiuha, and Mezhyrichchya. For the Ukrainian version of this report, see NREL/TP-7A40-90360 (https://www.nrel.gov/docs/fy24osti/90360.pdf).

14 SOLAR ENERGY↗

ТЕХНІКО-ЕКОНОМІЧНИЙ АНАЛІЗ ПОТЕНЦІАЛУ ІНТЕГРАЦІЇ РОЗПОДІЛЕНИХ ЕНЕРГЕТИЧНИХ РЕСУРСІВ ДЛЯ ВОДОКАНАЛУ М.ЧЕРВОНОГРАД В УКРАЇНІ [Technical and Economic Screening for Potential of Distributed Energy Resource Integration at Chervonohrad Water Utility in Ukraine] (Ukrainian Translation)

In this report, the authors present a preliminary techno-economic screening for distributed renewable energy for Chervonohrad Vodokanal, the water utility in Chervonohrad, Ukraine. The screening estimates the technical potential and economics of integrating solar photovoltaics (PV) and battery energy storage systems (BESS) at Chervonohrad Vodokanal water pumping stations, Pravda, Bendiuha, and Mezhyrichchya. For the English version of this report, see NREL/TP-7A40-89599 (https://www.nrel.gov/docs/fy24osti/89599.pdf).

14 SOLAR ENERGY↗

Electric Vehicle Charging Data Falsification Attacks Utilizing Behavioral Models

A charging station (CS) and its associated electric vehicle supply equipment (EVSE) and charging electric vehicle (EV) interactions are potential targets for data falsification attacks since CSs are typically unmanned public facilities that are connected to the internet and EVs incorporate the vulnerable CAN bus network, which are both susceptible to remote attacks. The research question being addressed is how is the EV owner and CS negatively affected by CAN bus EV battery current sensor and battery temperature sensor data falsification attacks. Negative effects include economic losses from reduced life span of the battery, battery thermal runaway and fire (and potential loss of surrounding structure), and reduced utilization of the CS due to delayed departure time (longer charging times).

25 ENERGY STORAGE↗

State Spotlight on Resilience: The Washington Utilities and Transportation Commission’s Wildfire Mitigation Plans

Wildfires present a significant risk to critical infrastructure, endangering energy systems by damaging transmission lines and imposing a variety of costs on utilities and their customers. Wildfires have increased nationally in both extent and intensity as vegetation conditions become drier and wind patterns become more turbulent. Aging infrastructure may also cause transmission lines to ignite vegetation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A method for modeling battery-temperature-aware EV power profiles utilizing Next-Gen Profile data

With the expected increase in the number of electric vehicles (EVs) on the road in the coming years, it is important that analysis tools are capable of modeling and predicting the expected load on the power grid due to both individual EV charging sessions as well as large populations of vehicles. To do this accurately, the power profile of an EV charge session must be accurately modeled, including for scenarios where the temperature is above or below the ideal, and also take into account the nuances of manufacturer charging preferences. This paper introduces a method that utilizes the data in the Next-Gen Profile (NGP) data collection project to build a model of EV charging that takes into account the variations in charging power that occur due to off-nominal battery temperature and manufacturer preferences that limit power due to cold temperatures or high battery state-of-charge.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Digital Twin User Guide for Chelan County Public Utility District

This user manual offers a comprehensive guide for developing a Digital twin (DT) of a Kaplan turbine at Chelan County Public Utility District (Chelan PUD) using neural networks. As variable renewable generation expands, hydropower units must operate with optimal efficiency and stability. For Kaplan machines, this flexibility is achieved through coordinated control of guide vane (wicket gates) opening and runner blade pitch, which amplifies the plant’s inherent nonlinear behavior and challenges traditional physics-only modeling. The efficiency of the Kaplan turbine varies with different combinations of the guide vans (wicket gate) opening and the blade angle. Each guide van opening and blade angle has a corresponding highest efficiency point, forming a cam relationship that represents the optimal combination.The discharge of a hydraulic turbine is controlled by the opening angle of the guide vans. Therefore, for each value of head, there is a certain guide van opening and blade angle that corresponds to the highest efficiency. For a given head, different combinations of the guide van opening and blade angle have different efficiencies. Therefore, coordinate cam curves are used to describe the relationship between the wicket gate opening and blade angle with different water head. To address these challenges, the manual details a data-driven modeling and learning workflow centered on structured neural networks. The approach is designed to forecast critical operational variables—discharge flow, net head, penstock (or scroll-case) pressure, and generator electrical outputs—by leveraging real-time inputs such as the generator power control setpoint, exciter field current and field voltage, together with hydromechanical commands (e.g., gate position and, when available, runner blade-pitch angle). The neural models are trained and validated on operational data from a Kaplan unit operated by Chelan PUD, demonstrating that the structured NN architecture can learn the coupled gate–blade–electrical dynamics. The result is a robust DT that improves situational awareness and supports data-informed decision-making for Chelan PUD’s Kaplan turbine operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Carbon Utilization and Storage Partnership of the Western United States

This technical report documents research conducted under DOE Award No. DE-FE0031837 focused on evaluating the feasibility of carbon capture, utilization, and storage (CCUS) systems in the central and western United States. The project integrated geologic characterization, reservoir simulation, infrastructure modeling, and economic analysis to assess CO₂ storage potential near industrial sources and develop strategies for transport and sequestration. The work included subsurface modeling, risk assessment, monitoring and verification (MRV) planning, and evaluation of regulatory pathways such as EPA Underground Injection Control (UIC) Class VI permitting and IRS 45Q tax credit eligibility. Results demonstrate the viability of multiple storage approaches, including saline formations, enhanced coalbed methane recovery, and basalt mineralization, supported by data-driven workflows and regional analyses. The project also produced permitting templates, technology transfer activities, and stakeholder engagement efforts to support deployment readiness. These findings contribute to the development of scalable, economically viable CCUS systems and provide a repeatable framework for future carbon management projects.

20 FOSSIL-FUELED POWER PLANTS↗