Search NASA⌕ Search

SEARCH · Search NASA

Results for “validation data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Aeroservoelastic Model Validation and Test Data Analysis of the F/A-18 Active Aeroelastic Wing

Model validation and flight test data analysis require careful consideration of the effects of uncertainty, noise, and nonlinearity. Uncertainty prevails in the data analysis techniques and results in a composite model uncertainty from unmodeled dynamics, assumptions and mechanics of the estimation procedures, noise, and nonlinearity. A fundamental requirement for reliable and robust model development is an attempt to account for each of these sources of error, in particular, for model validation, robust stability prediction, and flight control system development. This paper is concerned with data processing procedures for uncertainty reduction in model validation for stability estimation and nonlinear identification. F/A-18 Active Aeroelastic Wing (AAW) aircraft data is used to demonstrate signal representation effects on uncertain model development, stability estimation, and nonlinear identification. Data is decomposed using adaptive orthonormal best-basis and wavelet-basis signal decompositions for signal denoising into linear and nonlinear identification algorithms. Nonlinear identification from a wavelet-based Volterra kernel procedure is used to extract nonlinear dynamics from aeroelastic responses, and to assist model development and uncertainty reduction for model validation and stability prediction by removing a class of nonlinearity from the uncertainty.

Brenner, Martin J.↗

A Feasibility Study to Determine Cooling Time and Burnup of ATR Fuel Using a Nondestructive Technique and Three Types of Gamma-ray Detectors

A Feasibility Study to Determine Cooling Time and Burnup of ATR Fuel Using a Nondestructive Technique1 Rahmat Aryaeinejad, Jorge Navarro, and David W Nigg Idaho National Laboratory Abstract Effective and efficient Advanced Test Reactor (ATR) fuel management require state of the art core modeling tools. These new tools will need isotopic and burnup validation data before they are put into production. To create isotopic, burn up validation libraries and to determine the setup for permanent fuel scanner system a feasibility study was perform. The study consisted in measuring short and long cooling time fuel elements at the ATR canal. Three gamma spectroscopy detectors (HPGe, LaBr3, and HPXe) and two system configurations (above and under water) were used in the feasibility study. The first stage of the study was to investigate which detector and system configuration would be better suited for different scenarios. The second stage of the feasibility study was to create burnup and cooling time calibrations using experimental isotopic data collected and ORIGEN 2.2 burnup data. The results of the study establish that a better spectra resolution is achieve with an above the water configuration and that three detectors can be used in the permanent fuel scanner system for different situations. In addition it was conclude that a number of isotopic ratios and absolute measurements could be used to predict ATR fuel burnup and cooling times. 1This work was supported by the U.S. Depart¬ment of Energy (DOE) under Battelle Energy Alliance, LLC Contract No. DE-AC07-05ID14517.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Foundation Heat Exchanger Final Report: Demonstration, Measured Performance, and Validated Model and Design Tool

Geothermal heat pumps, sometimes called ground-source heat pumps (GSHPs), have been proven capable of significantly reducing energy use and peak demand in buildings. Conventional equipment for controlling the temperature and humidity of a building, or supplying hot water and fresh outdoor air, must exchange energy (or heat) with the building's outdoor environment. Equipment using the ground as a heat source and heat sink consumes less non-renewable energy (electricity and fossil fuels) because the earth is cooler than outdoor air in summer and warmer in winter. The most important barrier to rapid growth of the GSHP industry is high first cost of GSHP systems to consumers. The most common GSHP system utilizes a closed-loop ground heat exchanger. This type of GSHP system can be used almost anywhere. There is reason to believe that reducing the cost of closed-loop systems is the strategy that would achieve the greatest energy savings with GSHP technology. The cost premium of closed-loop GSHP systems over conventional space conditioning and water heating systems is primarily associated with drilling boreholes or excavating trenches, installing vertical or horizontal ground heat exchangers, and backfilling the excavations. This project investigates reducing the cost of horizontal closed-loop ground heat exchangers by installing them in the construction excavations, augmented when necessary with additional trenches. This approach applies only to new construction of residential and light commercial buildings or additions to such buildings. In the business-as-usual scenario, construction excavations are not used for the horizontal ground heat exchanger (HGHX); instead the HGHX is installed entirely in trenches dug specifically for that purpose. The potential cost savings comes from using the construction excavations for the installation of ground heat exchangers, thereby minimizing the need and expense of digging additional trenches. The term foundation heat exchanger (FHX) has been coined to refer exclusively to ground heat exchangers installed in the overcut around the basement walls. The primary technical challenge undertaken by this project was the development and validation of energy performance models and design tools for FHX. In terms of performance modeling and design, ground heat exchangers in other construction excavations (e.g., utility trenches) are no different from conventional HGHX, and models and design tools for HGHX already exist. This project successfully developed and validated energy performance models and design tools so that FHX or hybrid FHX/HGHX systems can be engineered with confidence, enabling this technology to be applied in residential and light commercial buildings. The validated energy performance model also addresses and solves another problem, the longstanding inadequacy in the way ground-building thermal interaction is represented in building energy models, whether or not there is a ground heat exchanger nearby. Two side-by-side, three-level, unoccupied research houses with walkout basements, identical 3,700 ft{sup 2} floor plans, and hybrid FHX/HGHX systems were constructed to provide validation data sets for the energy performance model and design tool. The envelopes of both houses are very energy efficient and airtight, and the HERS ratings of the homes are 44 and 45 respectively. Both houses are mechanically ventilated with energy recovery ventilators, with space conditioning provided by water-to-air heat pumps with 2 ton nominal capacities. Separate water-to-water heat pumps with 1.5 ton nominal capacities were used for water heating. In these unoccupied research houses, human impact on energy use (hot water draw, etc.) is simulated to match the national average. At House 1 the hybrid FHX/HGHX system was installed in 300 linear feet of excavation, and 60% of that was construction excavation (needed to construct the home). At House 2 the hybrid FHX/HGHX system was installed in 360 feet of excavation, 50% of which was construction excavation. There are six pipes in all excavations (three parallel circuits - out and back), and the multiple instances of FHX and/or HGHX are all connected in series. The working fluid is 20% by weight propylene glycol in water. Model and design tool development was undertaken in parallel with constructing the houses, installing instrumentation, and monitoring performance for a year. Several detailed numerical models for FHX were developed as part of the project. Essentially the project team was searching for an energy performance model accurate enough to achieve project objectives while also having sufficient computational efficiency for practical use in EnergyPlus. A 3-dimensional, dual-coordinate-system, finite-volume model satisfied these criteria and was included in the October 2011 EnergyPlus Version 7 public release after being validated against measured data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Foundation Heat Exchanger Final Report: Demonstration, Measured Performance, and Validated Model and Design Tool

Geothermal heat pumps, sometimes called ground-source heat pumps (GSHPs), have been proven capable of significantly reducing energy use and peak demand in buildings. Conventional equipment for controlling the temperature and humidity of a building, or supplying hot water and fresh outdoor air, must exchange energy (or heat) with the building's outdoor environment. Equipment using the ground as a heat source and heat sink consumes less non-renewable energy (electricity and fossil fuels) because the earth is cooler than outdoor air in summer and warmer in winter. The most important barrier to rapid growth of the GSHP industry is high first cost of GSHP systems to consumers. The most common GSHP system utilizes a closed-loop ground heat exchanger. This type of GSHP system can be used almost anywhere. There is reason to believe that reducing the cost of closed-loop systems is the strategy that would achieve the greatest energy savings with GSHP technology. The cost premium of closed-loop GSHP systems over conventional space conditioning and water heating systems is primarily associated with drilling boreholes or excavating trenches, installing vertical or horizontal ground heat exchangers, and backfilling the excavations. This project investigates reducing the cost of horizontal closed-loop ground heat exchangers by installing them in the construction excavations, augmented when necessary with additional trenches. This approach applies only to new construction of residential and light commercial buildings or additions to such buildings. In the business-as-usual scenario, construction excavations are not used for the horizontal ground heat exchanger (HGHX); instead the HGHX is installed entirely in trenches dug specifically for that purpose. The potential cost savings comes from using the construction excavations for the installation of ground heat exchangers, thereby minimizing the need and expense of digging additional trenches. The term foundation heat exchanger (FHX) has been coined to refer exclusively to ground heat exchangers installed in the overcut around the basement walls. The primary technical challenge undertaken by this project was the development and validation of energy performance models and design tools for FHX. In terms of performance modeling and design, ground heat exchangers in other construction excavations (e.g., utility trenches) are no different from conventional HGHX, and models and design tools for HGHX already exist. This project successfully developed and validated energy performance models and design tools so that FHX or hybrid FHX/HGHX systems can be engineered with confidence, enabling this technology to be applied in residential and light commercial buildings. The validated energy performance model also addresses and solves another problem, the longstanding inadequacy in the way ground-building thermal interaction is represented in building energy models, whether or not there is a ground heat exchanger nearby. Two side-by-side, three-level, unoccupied research houses with walkout basements, identical 3,700 ft{sup 2} floor plans, and hybrid FHX/HGHX systems were constructed to provide validation data sets for the energy performance model and design tool. The envelopes of both houses are very energy efficient and airtight, and the HERS ratings of the homes are 44 and 45 respectively. Both houses are mechanically ventilated with energy recovery ventilators, with space conditioning provided by water-to-air heat pumps with 2 ton nominal capacities. Separate water-to-water heat pumps with 1.5 ton nominal capacities were used for water heating. In these unoccupied research houses, human impact on energy use (hot water draw, etc.) is simulated to match the national average. At House 1 the hybrid FHX/HGHX system was installed in 300 linear feet of excavation, and 60% of that was construction excavation (needed to construct the home). At House 2 the hybrid FHX/HGHX system was installed in 360 feet of excavation, 50% of which was construction excavation. There are six pipes in all excavations (three parallel circuits - out and back), and the multiple instances of FHX and/or HGHX are all connected in series. The working fluid is 20% by weight propylene glycol in water. Model and design tool development was undertaken in parallel with constructing the houses, installing instrumentation, and monitoring performance for a year. Several detailed numerical models for FHX were developed as part of the project. Essentially the project team was searching for an energy performance model accurate enough to achieve project objectives while also having sufficient computational efficiency for practical use in EnergyPlus. A 3-dimensional, dual-coordinate-system, finite-volume model satisfied these criteria and was included in the October 2011 EnergyPlus Version 7 public release after being validated against measured data.

15 GEOTHERMAL ENERGY↗

Validation for {sup 233}U-Fueled Systems in KENO V.a in SCALE 6.2

Validation of the KENO V.a Monte Carlo code has been performed in recent years using benchmark experiments contained in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The models used in these recent validation efforts have been drawn from the Verified, Archived Library of Inputs and Data (VALID). Models must be generated and reviewed by qualified individuals to be added to the VALID library, which leads to high confidence in the models and reduces the probability that apparent validation issues are a result of modeling errors. The contents of the VALID library are somewhat limited because of the effort involved in generating and reviewing models, so no {sup 233}U-fueled experiments are included in VALID. A large number of models of {sup 233}U experiments have been modeled in the past in support of the criticality safety of {sup 233}U in storage at Oak Ridge National Laboratory (ORNL). In June, 2016, two midshipmen from the United States Naval Academy were assigned to ORNL, and they reviewed and updated these models for execution in SCALE 6.2. The validation of {sup 233}U is of interest because some discrepancies in SCALE results were identified by a beta tester at the Nuclear Energy Agency modeling these systems. These discrepancies were related to a data thinning procedure in the continuous-energy nuclear data process, and had been resolved prior to the release of SCALE 6.2. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Comparison of Organ Dose and Dose Equivalent Using Ray Tracing of Male and Female Voxel Phantoms to Space Flight Phantom Torso Data

Phantom torso experiments have been flown on the space shuttle and International Space Station (ISS) providing validation data for radiation transport models of organ dose and dose equivalents. We describe results for space radiation organ doses using a new human geometry model based on detailed Voxel phantoms models denoted for males and females as MAX (Male Adult voXel) and Fax (Female Adult voXel), respectively. These models represent the human body with much higher fidelity than the CAMERA model currently used at NASA. The MAX and FAX models were implemented for the evaluation of directional body shielding mass for over 1500 target points of major organs. Radiation exposure to solar particle events (SPE), trapped protons, and galactic cosmic rays (GCR) were assessed at each specific site in the human body by coupling space radiation transport models with the detailed body shielding mass of MAX/FAX phantom. The development of multiple-point body-shielding distributions at each organ site made it possible to estimate the mean and variance of space dose equivalents at the specific organ. For the estimate of doses to the blood forming organs (BFOs), active marrow distributions in adult were accounted at bone marrow sites over the human body. We compared the current model results to space shuttle and ISS phantom torso experiments and to calculations using the CAMERA model.

Kim, Myung-Hee Y.↗

Raw tensiometer soil matric potential data, from Oct 2017-Jun 2020 in Manaus, Brazil

This data package contains raw output from two Campbell Scientific CR1000 data loggers each connected to three UMS T4e tensiometer sensors in Manaus, Brazil. Tensiometers at each data logger location were installed to depths of 10 cm, 20 cm and 50 cm below the ground surface for the purpose of measuring soil matric potential at each depth. “Station 3” tensiometers were installed at approximately 2°36'31.68"S, 60°12'34.70"W. “Station 4” tensiometers were installed at approximately 2°36'32.46"S, 60°12'34.92"W. The files “tensio3.edit.202109.csv” and “tensio4.edit.202109.csv” contain raw data (with invalid data removed). A text editor will be required to view the raw files in .csv (comma-separated values) format. Data processing was limited to: 1) Editing column headers for clarity; 2) Applying a correction that converts voltage read by the data loggers to pressure units (kPa); 3) removing all data greater than 50 kPa and less than -115 kPa; 4) Adding columns entitled “Caution.10cm”, “Caution.20cm” and “Caution.50cm” that contains values of either “NA” or “Caution”, the latter of which is applied when data exceeds the manufacturer reported data validity range of less than -85 kPa to suggest use of these data with caution; 5) Adding columns entitled “Invalid.10cm”, “Invalid.20cm”, and “Invalid.50cm” that contains values of either “NA” or “Invalid”, the latter of which is applied when data accuracy is deemed compromised due to the introduction of air bubbles into the instrument. Data marked “Invalid” may still indicate general trends of wet/high matric potential and dry/low matric potential, but values are inaccurate and dry/low matric potential values are likely not low enough. Wet/high matric potential values are likely to be more accurate than dry/low matric potential values; 6) Data format changed from .dat to .csv. This research was performed as a part of the NGEE Tropics project, which aims to advance model predictions of tropical forest carbon cycle responses to a changing climate over the 21st Century.

54 ENVIRONMENTAL SCIENCES↗

Computational simulation of liquid fuel rocket injectors

A major component of any liquid propellant rocket is the propellant injection system. Issues of interest include the degree of liquid vaporization and its impact on the combustion process, the pressure and temperature fields in the combustion chamber, and the cooling of the injector face and chamber walls. The Finite Difference Navier-Stokes (FDNS) code is a primary computational tool used in the MSFC Computational Fluid Dynamics Branch. The branch has dedicated a significant amount of resources to development of this code for prediction of both liquid and solid fuel rocket performance. The FDNS code is currently being upgraded to include the capability to model liquid/gas multi-phase flows for fuel injection simulation. An important aspect of this effort is benchmarking the code capabilities to predict existing experimental injection data. The objective of this MSFC/ASEE Summer Faculty Fellowship term was to evaluate the capabilities of the modified FDNS code to predict flow fields with liquid injection. Comparisons were made between code predictions and existing experimental data. A significant portion of the effort included a search for appropriate validation data. Also, code simulation deficiencies were identified.

Landrum, D. Brian↗

A Whale of a Tale: Creating Spacecraft Telemetry Data Analysis Products for the Deep Impact Mission

A description of the Whale product generation utility and its means of analyzing project data for Deep Impact Missions is presented. The topics include: 1) Whale Definition; 2) Whale Overview; 3) Whale Challenges; 4) Network Configuration; 5) Network Diagram; 6) Whale Data Flow: Design Decisions; 7) Whale Data Flow Diagram; 8) Whale Data Flow; 9) Whale Team and Users; 10) Creeping Requirements; 11) Whale Competition; 12) Statistics: Processing Time; 13) CPU and Disk Usage; 14) The Ripple Effect of More Data; and 15) Data Validation and the Automation Challenge.

ground data systems↗

A crust and upper mantle model of Eurasia and North Africa for Pn travel time calculation

We develop a Regional Seismic Travel Time (RSTT) model and methods to account for the first-order effect of the three-dimensional crust and upper mantle on travel times. The model parameterization is a global tessellation of nodes with a velocity profile at each node. Interpolation of the velocity profiles generates a 3-dimensional crust and laterally variable upper mantle velocity. The upper mantle velocity profile at each node is represented as a linear velocity gradient, which enables travel time computation in approximately 1 millisecond. This computational speed allows the model to be used in routine analyses in operational monitoring systems. We refine the model using a tomographic formulation that adjusts the average crustal velocity, mantle velocity at the Moho, and the mantle velocity gradient at each node. While the RSTT model is inherently global and our ultimate goal is to produce a model that provides accurate travel time predictions over the globe, our first RSTT tomography effort covers Eurasia and North Africa, where we have compiled a data set of approximately 600,000 Pn arrivals that provide path coverage over this vast area. Ten percent of the tomography data are randomly selected and set aside for testing purposes. Travel time residual variance for the validation data is reduced by 32%. Based on a geographically distributed set of validation events with epicenter accuracy of 5 km or better, epicenter error using 16 Pn arrivals is reduced by 46% from 17.3 km (ak135 model) to 9.3 km after tomography. Relative to the ak135 model, the median uncertainty ellipse area is reduced by 68% from 3070 km{sup 2} to 994 km{sup 2}, and the number of ellipses with area less than 1000 km{sup 2}, which is the area allowed for onsite inspection under the Comprehensive Nuclear Test Ban Treaty, is increased from 0% to 51%.

58 GEOSCIENCES↗

Evidence of Completion of Milestone 4: Simulation Testbed Validated with Experimental Data

Milestone 4 is given in the SOPO as being due in quarter 5 (ending 9/11/2020) and is described thus: Milestone 4: Enhanced Simulation Testbed Validated with Experimental Data (UM, Mathieu). Simulation testbed validated with data obtained from experimental testbed, specifically, nonlinear load behaviors and communication network issues observed in the experimental testbed will be modeled in the simulation testbed. The simulation testbed should accurately capture TCL real and reactive power consumption (including during extreme events associated with nonlinear behaviors and communication network failures) to within 5% RMSE error with respect to data obtained from the experimental testbed. The Tasks comprising the work to achieve Milestone 4 are outlined here.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evidence of Completion of Milestone 4: Simulation Testbed Validated with Experimental Data

Milestone 4 is given in the SOPO as being due in quarter 5 (ending 9/11/2020) and is described thus: Milestone 4: Enhanced Simulation Testbed Validated with Experimental Data (UM, Mathieu) Simulation testbed validated with data obtained from experimental testbed, specifically, nonlinear load behaviors and communication network issues observed in the experimental testbed will be modeled in the simulation testbed. The simulation testbed should accurately capture TCL real and reactive power consumption (including during extreme events associated with nonlinear behaviors and communication network failures) to within 5% RMSE error with respect to data obtained from the experimental testbed.

99 GENERAL AND MISCELLANEOUS↗

3D Material Response of the MSL Heatshield Using NuSil-Coated PICA

The Mars Science Laboratory (MSL) was protected during its atmospheric entry by an instrumented heatshield that used NASA's Phenolic Impregnated Carbon Ablator (PICA) material [1]. PICA is a lightweight carbon fiber/polymeric resin material that offers outstanding performance for protecting probes during planetary entry. Data from the Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of material response and atmospheric entry. MEDLI recorded, among other things, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP) [2]. A space-grade silicone-based coating commercially known as NuSil CV-1144-0 [3] was applied to the entire MSL heatshield, including the MEDLI plugs, to mitigate the spread of dust from PICA. Modeling the thermal response of PICA-NuSil (PICA-N) system is still an open challenge. Ground testing of PICA-N models exhibited surface temperature jumps of the order of 150 K due to oxide scale formation and sub-sequent NuSil burn-off. It is therefore critical to include a validated model for the material response of the coating in engineering codes. A test campaign has been conducted at the NASA’s Langley HyMETS [4] facility to screen the response of PICA-N and gather detailed data on its behavior [5]. A first model of PICA-N thermal response has been developed using the Hy-METS experiments [6]. The objective of this work is to analyze the material response of the latest PICA-N model compared to the engineering model used to simulate the entry of MSL. The environment and material response around the MSL aeroshell during Mars atmospheric entry is simulated using a collection of tools. The Direct Simulation Monte Carlo SPARTA code [7] is used in the rarefied regime, the Data Parallel Line Relaxation (DPLR) code [8] is used in the continuum regime and radiative heating conditions are provided by the Nonequilibrium air radiation (NEQAIR) code [9] to estimate the environmental conditions. The thermal response inside the material is computed using the Porous material Analysis Toolbox based on Open-FOAM (PATO) [10,11,12]. Thermodynamic and chemistry properties are estimated using the Mutation++ library [13]. The approach implemented in PATO as a first cut PICA-N thermal response model is outlined in Figure 1. While the recession is less than the coating thickness, the Surface mass and energy balance Boundary Condition (SBC) uses the NuSil B’ tables. Once the recession removes the coating, the usual PICA B’ tables are used for the SBC. The B’ tables are computed using an equilibrium solver implemented in Mutation++, given the temperature, pressure, blowing rate, composition of the pyrolysis and environment gases, and the condensed species at the surface. Preliminary results of the 3D material response of the MSL heat-shield at the peak heating (80 sec after Entry Interface) are shown in Figure 2. Current NASA’s mission to Mars, Mars 2020, used the spare heatshield of MSL for thermal protection during entry, descent, and landing. In preparation for Mars 2020 post-flight analysis, the PATO high-fidelity material response capability was benchmarked against flight data from MEDLI. This effort represents an important milestone toward the development of validated predictive capabilities for designing thermal protection systems for planetary probes. This bench-marking is awaiting the final release of the MEDLI-2 data.

Aerospace↗

A Machine Learning Approach to Jet-Surface Interaction Noise Modeling

This paper investigates using machine learning to rapidly develop empirical models suitable for system-level aircraft noise studies. In particular, machine learning is used to train a neural network to predict the noise spectra produced by a round jet near a surface over a range of surface lengths, surface standoff distances, jet Mach numbers, and observer angles. These spectra include two sources, jet-mixing noise and jet-surface interaction (JSI) noise, with different scale factors as well as surface shielding and reflection effects to create a multi- dimensional problem. A second model is then trained using data from three rectangular nozzles to include nozzle aspect ratio in the spectral prediction. The training and validation data are from an extensive jet-surface interaction noise database acquired at the NASA Glenn Research Center's Aero-Acoustic Propulsion Laboratory. Although the number of training and validation points is small compared a typical machine learning application, the results of this investigation show that this approach is viable if the underlying data are well behaved.

Brown, Cliff↗

Mars Sample Return Earth Entry System Woven Roughness Mach 6 Aeroheating Test

The Mars Sample Return Earth Entry System is the first entry vehicle designed for a NASA flagship mission to utilize a woven thermal protection system as well as a 52.5 degree sphere cone forebody geometry. As a result, no heritage aeroheating experimental data set exists to compare with computational predictions. In order to obtain a set of validation data for computational models, an extensive wind tunnel test campaign was funded by the Mars Sample Return Earth Entry System project. The first entry in the test campaign was completed in April of 2023, which was an investigation of turbulent heating augmentation due to woven thermal protection system roughness on the 52.5 degree Mars Sample Return - Earth Entry System vehicle forebody geometry. This test entry produced the first ever experimental aeroheating data on a 52.5 degree sphere-cone geometry as well as the first NASA experimental aeroheating data on a woven surface roughness pattern. Data obtained from this test campaign is being directly leveraged to support the NASA flight program, as experimental results are being utilized to validate the computational models which characterize the aeroheating environment that the vehicle experiences and predict turbulent surface heating levels and margins across the woven surface.

Jonathan S Cheatwood↗

Mars Sample Return Earth Entry System Woven Roughness Mach 6 Aeroheating Test

The Mars Sample Return Earth Entry System is the first entry vehicle designed for a NASA flagship mission to utilize a woven thermal protection system as well as a 52.5 degree sphere cone forebody geometry. As a result, no heritage aeroheating experimental data set exists to compare with computational predictions. In order to obtain a set of validation data for computational models, an extensive wind tunnel test campaign was funded by the Mars Sample Return Earth Entry System project. The first entry in the test campaign was completed in April of 2023, which was an investigation of turbulent heating augmentation due to woven thermal protection system roughness on the 52.5 degree Mars Sample Return - Earth Entry System vehicle forebody geometry. This test entry produced the first ever experimental aeroheating data on a 52.5 deg sphere-cone geometry as well as the first NASA experimental aeroheating data on a woven surface roughness pattern. Data obtained from this test campaign is being directly leveraged to support the NASA flight program, as experimental results are being utilized to validate the computational models which characterize the aeroheating environment that the vehicle experiences and predict turbulent surface heating levels and margins across the woven surface.

Jonathan Cheatwood↗

Prediction and Computation of Corrosion Rates of A36 Mild Steel in Oilfield Seawater

The parameters which primarily control the corrosion rate and life of steel structures are several and they vary across the different ocean and seawater as well as along the depth. While the effect of single parameter on corrosion behavior is known, the conjoint effects of multiple parameters and the interrelationship among the variables are complex. Millions sets of experiments are required to understand the mechanism of corrosion failure. Statistical modeling such as ANN is one solution that can reduce the number of experimentation. ANN model was developed using 170 sets of experimental data of A35 mild steel in simulated seawater, varying the corrosion influencing parameters SO{sub 4}{sup 2−}, Cl{sup −}, HCO{sub 3}{sup −},CO{sub 3}{sup 2−}, CO{sub 2}, O{sub 2}, pH and temperature as input and the corrosion current as output. About 60% of experimental data were used to train the model, 20% for testing and 20% for validation. The model was developed by programming in Matlab. 80% of the validated data could predict the corrosion rate correctly. Corrosion rates predicted by the ANN model are displayed in 3D graphics which show many interesting phenomenon of the conjoint effects of multiple variables that might throw new ideas of mitigation of corrosion by simply modifying the chemistry of the constituents. The model could predict the corrosion rates of some real systems.

36 MATERIALS SCIENCE↗

A comparative analysis of green building rating systems in China and the United States

Several studies have compared green building rating systems (GBRSs) in China and the United States, Nonetheless, few studies included in-depth analysis on specific rating tools with project specific data validating green building technologies and actual performance. This study conducted a comprehensive data-driven comparison of the GBRSs of China and the United States. The goal was to understand the current status and further improve China's GBRS and promote green building technologies. The study first conducted thorough comparisons of GBRSs in China and the U.S. by selecting a series of distinct rating tools. Then, it analyzed each tool's development objectives, contents, and rating score settings. Further, the comparison concludes the future development needs for China's GBRS. In addition to standard comparison, green building technologies applied in certified projects were also summarized. The results demonstrated that GBRSs in both China and the U.S. reflect well the technical paths to achieve green building sustainable development. By analyzing certified projects, it was also found that the incremental costs of green building technologies were controllable. Finally, based on the comparison and case analysis, the study provide a set of policy recommendations to further improve China's green building standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗