Search NASA⌕ Search

SEARCH · Search NASA

Results for “volume of fluid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

An Accuracy Evaluation of Unstructured Node-Centred Finite Volume Methods

Node-centred edge-based finite volume approximations are very common in computational fluid dynamics since they are assumed to run on structured, unstructured and even on mixed grids. We analyse the accuracy properties of both first and second derivative approximations and conclude that these schemes can not be used on arbitrary grids as is often assumed. For the Euler equations first-order accuracy can be obtained if care is taken when constructing the grid. For the Navier-Stokes equations, the grid restrictions are so severe that these finite volume schemes have little advantage over structured finite difference schemes. Our theoretical results are verified through extensive computations.

Svard, Magnus↗

Aspects of unstructured grids and finite-volume solvers for the Euler and Navier-Stokes equations

Basic algorithms for unstructured mesh generation and fluid flow calculation are discussed. In particular the following are addressed: preliminaries of graphs and meshes; duality and data structures; basic graph operations important in CFD (Computational Fluid Dynamics); triangulation methods, including Varonoi diagrams and Delaunay triangulation; maximum principle analysis; finite volume schemes for scalar conservation law equations; finite volume schemes for the Euler and Navier-Stokes equations; and convergence acceleration for steady state calculations.

Barth, T. J.↗

Increased renal tubular sodium reabsorption during exercise-induced hypervolemia in humans

We tested the hypothesis that renal tubular Na(+) reabsorption increased during the first 24 h of exercise-induced plasma volume expansion. Renal function was assessed 1 day after no-exercise control (C) or intermittent cycle ergometer exercise (Ex, 85% of peak O(2) uptake) for 2 h before and 3 h after saline loading (12.5 ml/kg over 30 min) in seven subjects. Ex reduced renal blood flow (p-aminohippurate clearance) compared with C (0.83 +/- 0.12 vs. 1.49 +/- 0.24 l/min, P < 0.05) but did not influence glomerular filtration rates (97 +/- 10 ml/min, inulin clearance). Fractional tubular reabsorption of Na(+) in the proximal tubules was higher in Ex than in C (P < 0.05). Saline loading decreased fractional tubular reabsorption of Na(+) from 99.1 +/- 0.1 to 98.7 +/- 0.1% (P < 0.05) in C but not in Ex (99.3 +/- 0.1 to 99.4 +/- 0.1%). Saline loading reduced plasma renin activity and plasma arginine vasopressin levels in C and Ex, although the magnitude of decrease was greater in C (P < 0.05). These results indicate that, during the acute phase of exercise-induced plasma volume expansion, increased tubular Na(+) reabsorption is directed primarily to the proximal tubules and is associated with a decrease in renal blood flow. In addition, saline infusion caused a smaller reduction in fluid-regulating hormones in Ex. The attenuated volume-regulatory response acts to preserve distal tubular Na(+) reabsorption during saline infusion 24 h after exercise.

NASA Discipline Cardiopulmonary↗

Clinical Aspects of the Control of Plasma Volume at Microgravity and During Return to One Gravity

Plasma volume is reduced by 10%-20% within 24 to 48 h of exposure to simulated or actual microgravity. The clinical importance of microgravity-induced hypovolemia is manifested by its relationship with orthostatic intolerance and reduced VO2max after return to one gravity (1G). Since there is no evidence to suggest plasma volume reduction during microgravity is associated with thirst or renal dysfunctions, a diuresis induced by an immediate blood volume shift to the central circulation appears responsible for microgravity-induced hypovolemia. Since most astronauts choose to restrict their fluid intake before a space mission, absence of increased urine output during actual spaceflight may be explained by low central venous pressure (CVP) which accompanies dehydration. Compelling evidence suggests that prolonged reduction in CVP during exposure to microgravity reflects a 'resetting' to a lower operating point which acts to limit plasma volume expansion during attempts to increase fluid intake. In groudbase and spaceflight experiments, successful restoration and maintenance of plasma volume prior to returning to an upright posture may depend upon development of treatments that can return CVP to its baseline 10 operating point. Fluid-loading and LBNP have not proved completely effective in restoring plasma volume, suggesting that they may not provide the stimulus to elevate the CVP operating point. On the other, exercise, which can chronically increase CVP, has been effective in expanding plasma volume when combined with adequate dietary intake of fluid and electrolytes. The success of designing experiments to understand the physiological mechanisms of and development of effective countermeasures for the control of plasma volume in microgravity and during return to one gravity will depend upon testing that can be conducted under standardized controlled baseline condi

Convertino, Victor A.↗

Metabolic changes observed in astronauts

Results of medical experiments with astronauts reveal rapid loss of volume (2 l) from the legs and a transient early increase in left ventricular volume index. These findings indicate that, during space flight, fluid is redistributed from the legs toward the head. In about 2 days, total body water decreases 2 to 3 percent. Increased levels of plasma renin activity and antidiuretic hormone while blood sodium and plasma volume are reduced suggest that space flight-associated factors are influencing the regulatory systems. In addition to fluid and electrolyte loss, Skylab astronauts lost an estimated 0.3 kg of protein. Endocrine factors, including increased cortisol and thyroxine and decreased insulin, are favorable for protein catabolism. The body appears to adapt to weightlessness at some physiologic cost. Readaptation to earth's gravity at landing becomes another physiologic challenge.

Leach, Carolyn S.↗

A model for plasma volume changes during short duration spaceflight

It is well established that plasma volume decreases during spaceflight and simulated weightlessness (bedrest). The decrement in plasma volume is thought to contribute to the orthostatic intolerance that has been observed in some crew members following spaceflight. To date, no studies have evaluated the effectiveness of fluid countermeasures of varying osmolality in the restoration of plasma volume and orthostatic tolerance in a controlled study. The overall objectives of this project were to: (1) provide a model that would rapidly and safely produce a fluid loss comparable to that which occurs during short duration spaceflight; and (2) design a study that would determine the optimal drink solution to restore orthostatic tolerance and describe the mechanism(s) whereby orthostatic tolerance is restored. In summary, Lasix can be used as a way of simulating the plasma volume changes that occur during short duration spaceflight. The total loss of plasma is comparable to spaceflight. Lasix is fast acting, and has relatively few side effects. The present design for evaluating the optimal fluid countermeasures will have important implications in restoring orthostatic tolerance and function in the latter stages of spaceflight when it is essential for safe operation of the spacecraft.

Davis, John E.↗

Improving adsorption cryocoolers by multi-stage compression and reducing void volume

It is shown that the performance of gas adsorption cryocoolers is greatly improved by using adsorbents with low void volume within and between individual adsorbent particles (reducing void volumes in plumbing lines), and by compressing the working fluid in more than one stage. Refrigerator specific power requirements and compressor volumetric efficiencies are obtained in terms of adsorbent and plumbing line void volumes and operating pressures for various charcoal adsorbents using an analytical model. Performance optimization curves for 117.5 and 80 K charcoal/nitrogen adsorption cryocoolers are given for both single stage and multistage compressor systems, and compressing the nitrogen in two stages is shown to lower the specific power requirements by 18 percent for the 117.5 K system.

Bard, S.↗

Intracranial Effects of Intermittent Lower Body Negative Pressure with Head Down Tilt Bed Rest: Comparison to Upright Posture

INTRODUCTION Spaceflight-associated neuro-ocular syndrome (SANS) affects a majority of astronauts during long-duration spaceflight. SANS is hypothesized to result from an unrelenting headward fluid shift that occurs in the microgravity environment. Altered intracranial structure and physiology documented in spaceflight and head-down tilt (HDT) experiments(1, 2) are also theorized to be related to chronic headward fluid shift and thereby can provide an independent quantitative assessment related to this mechanism. As a potential countermeasure, lower body negative pressure (LBNP) applied in the supine posture has shown efficacy in reducing headward fluid shift(3). However, it remains unknown if intermittent LBNP simulating daily upright posture fluid redistribution can mitigate SANS and intracranial changes associated with long-duration spaceflight. The goal of this study was to quantify the effects of daily application of LBNP or daily exposure to the upright posture on intracranial structure and physiology during long-term HDT in order to evaluate the potential efficacy of LBNP as a countermeasure to SANS. METHODS 22 healthy volunteers (11 men; 11 women; mean age = 35 years (SD=9.2)(age range = 24 to 52 years); mean BMI = 24.0 kg/m2 (SD=2.8)) completed an MRI study performed at the German Aerospace Facility in Cologne, Germany. Strict six-degree head-down tilt (HDT) bedrest was used as a spaceflight analog to induce a continuous headward fluid shift for 30 days. The subjects were divided equally into two groups of interventions: 1) LBNP for 3-hour sessions twice daily and 2) seated position for 3-hour sessions twice daily. Interventions were divided into morning and afternoon sessions for both groups. The LBNP intervention was maintained at 25 mmHg  2 mmHg. Pulse-gated MRI phase-contrast flow imaging was used to quantify cerebral artery stroke volume (CASV) and peak-to-peak cerebral spinal fluid (CSF) velocity (CSFVp-p) within the cerebral aqueduct. A 3D T1-MPRAGE sequence was used to quantify volumetric changes of the brain and intracranial CSF spaces using MRI Cloud software. MRI acquisitions were obtained at baseline (BDC, supine posture), 15 days into HDT (HDT15), 29 days into HDT (HDT29), and 12 days after recovery (R12, supine posture). The data were analyzed by a mixed model, which included intervention, time (four nominal levels BDC, HDT15, HDT29, R12), and intervention-time interaction as the fixed effects and included subject as a random effect. RESULTS Compared to BDC there was no statistically significant difference in CASV and CSFVp-p during HDT except for CASV at HDT29 (seated group) where there was a 1.7 mL (12%) decrease (P<0.01). Compared to BDC there was a statistically significant increase in intracranial volume (ICV; ICV = white matter + gray matter + CSF) for both interventions at HDT15 (Δ13 mL, 0.9 % (LBNP group); Δ15 mL, 1.0%, (seated group)) and HDT29 (Δ19 mL, 1.2%, (LBNP group); Δ23 mL, 1.5%) (seated group)) (All Ps<.001). Compared to baseline, lateral ventricular volume increased at HDT15 (Δ0.9 mL, 5.5%) and HDT29 (Δ1.8 mL, 10%)) for LBNP only (P=.001 for each). During HDT, white matter volume remained stable compared to baseline for both interventions. There were no significant intervention effects in the overall response to HDT (All Ps >.2). CONCLUSION LBNP had a similar response to the seated posture during 29 days of HDT. Although there was an increase in ICV and lateral ventricular volume with HDT there was no change in intracranial physiological parameters with LBNP suggesting an overall diminished response to the long-term effects of HDT. The lack of any significant increase in white matter volume during HDT with LBNP suggests maintenance of cerebral interstitial fluid transport. Final conclusions are pending the data collection for the control group (no intervention) which will be completed in 2023.

Larry A Kramer↗

The “Gravity” of Combustion, Fluid and Soft Matter Research

Over the next year, the National Academies of Science, Engineering and Medicine (NASEM) will be developing the report for the next Decadal Survey on Life and Physical Sciences Research in space 2023-2032. This document will be used by the Science Mission Directorate in the National Aeronautics and Space Administration (NASA) to provide the framework for the vision, priorities, and strategic plan and budget for NASA’s research efforts in the area of biological and physical sciences in space, especially with regards to effects of gravity or the lack thereof. Gravity can affect fluid motion, shapes interfacial boundaries, squeezes compressible volumes by their surroundings, and ultimately affects heat and mass transfer as well as chemical reactions. NASEM will be requesting input from the research community via white papers in order to generate a comprehensive vision and strategy for a decade of transformative science at the frontiers of science space. Note: Accompanying videos are included in this submission and are listed based on there corresponding slide. For viewing you will need to download each mp4 formatted video, total run time 4 mins 2 secs. w/ color/sound.

combustion↗

Clinical aspects of the control of plasma volume at microgravity and during return to one gravity

Plasma volume is reduced by 10-20% within 24-48 h of exposure to simulated or actual microgravity. The clinical importance of microgravity induced hypovolemia is manifested by its relationship with orthostatic intolerance and reduced maximal oxygen uptake (VO2max) after return to one gravity (1G). Since there is no evidence to suggest that plasma volume reduction during microgravity is associated with thirst or renal dysfunctions, a diuresis induced by an immediate blood volume shift to the central circulation appears responsible for microgravity-induced hypovolemia. Since most astronauts choose to restrict their fluid intake before a space mission, absence of increased urine output during actual space flight may be explained by low central venous pressure (CVP) which accompanies dehydration. Compelling evidence suggests that prolonged reduction in CVP during exposure to microgravity reflects a "resetting" to a lower operating point, which acts to limit plasma volume expansion during attempts to increase fluid intake. In ground based and space flight experiments, successful restoration and maintenance of plasma volume prior to returning to an upright posture may depend upon development of treatments that can return CVP to its baseline IG operating point. Fluid-loading and lower body negative pressure (LBNP) have not proved completely effective in restoring plasma volume, suggesting that they may not provide the stimulus to elevate the CVP operating point. On the other hand, exercise, which can chronically increase CVP, has been effective in expanding plasma volume when combined with adequate dietary intake of fluid and electrolytes. The success of designing experiments to understand the physiological mechanisms of and development of effective counter measures for the control of plasma volume in microgravity and during return to IG will depend upon testing that can be conducted under standardized controlled baseline conditions during both ground-based and space flight investigations.

Review, Tutorial↗

Langley Symposium on Aerodynamics, volume 1

The purpose of this work was to present current work and results of the Langley Aeronautics Directorate covering the areas of computational fluid dynamics, viscous flows, airfoil aerodynamics, propulsion integration, test techniques, and low-speed, high-speed, and transonic aerodynamics. The following sessions are included in this volume: theoretical aerodynamics, test techniques, fluid physics, and viscous drag reduction.

Stack, Sharon H.↗

Universal Features of the Fluid to Solid Transition for Attractive Colloidal Particles

Attractive colloidal particles can exhibit a fluid to solid phase transition if the magnitude of the attractive interaction is sufficiently large, if the volume fraction is sufficiently high, and if the applied stress is sufficiently small. The nature of this fluid to solid transition is similar for many different colloid systems, and for many different forms of interaction. The jamming phase transition captures the common features of these fluid to solid translations, by unifying the behavior as a function of the particle volume fraction, the energy of interparticle attractions, and the applied stress. This paper describes the applicability of the jamming state diagram, and highlights those regions where the fluid to solid transition is still poorly understood. It also presents new data for gelation of colloidal particles with an attractive depletion interaction, providing more insight into the origin of the fluid to solid transition.

Cipelletti, L.↗

X-15 hydraulic-system development

Despite the exacting requirements and conditions of the X-15 including much higher temperature, high horsepower, and extreme vibration and duty cycles, the hydraulic flight control systems compare favorably, weightwise, with preceding models. Although some items, such as the pumps, are heavier, the total system, excluding actuators, weighs approximately 195 pounds as compared with 196 pounds for the F-107A airplane. Use of the new piggy-back pump, with its low flow during most of the operating time, also permitted a reduction in fluid capacity of the hydraulic reservoirs and the total systems, even though the volume of some of the actuators is quite large. This effected a considerable saving in fluid weight. Complete ground-support equipment is available and this equipment, as well as the airplane systems, contains means for complete 5- to 15- micron filtration under controlled temperature conditions. By use of advanced engineering techniques and extensive laboratory testing, it has been possible to provide a sound, lightweight hydraulic system for this advanced, high-performance airplane. (author)

Culleton, R J↗

Propellant tank pressurization analysis program

Propellant tank pressurization analysis program considers fluid densities related to pressures and temperatures acting on the components, heat transfer between the fluids, the components, the ambient, plus component volumes, materials, and configurations in the formation of a mathematical model. This program is written in FORTRAN H and MAP.

Epstein, M.↗

Evaluation of advanced airship concepts

A historical overview of the airship, technical and operational characteristics of conventional and hybrid concepts, and the results of a parametric design analysis and evaluation are presented. The lift capabilities of certain buoyant fluids for a hypothetical 16 million cu.ft. volume airship are compared. The potential advanced airship concepts are surveyed, followed by a discussion of the six configurations: conventional nonrigid, conventional rigid, Deltoid (Dynairship), Guppoid (Megalifter), Helipsoid, and Heli-Stat. It is suggested that a partially buoyant Helipsoid concept of the optimum buoyancy ratio has the potential to solve the problems facing future airship development, such as Ballast and Ballast Recovery System, Full Low-Speed Controllability, Susceptibility to Wind/Gusting, Weather/Icing Constraints, Ground Handling/Hangaring, and Direct/Indirect Operating Costs.

Joner, B. A.↗

The effect of Tricresyl-Phosphate (TCP) as an additive on wear of Iron (Fe)

The effect of tricresyl phosphate (TCP) as an antiwear additive in lubricant trimethyol propane triheptanoate (TMPTH) was investigated. The objective was to examine step loading wear by use of surface analysis, wetting, and chemical bonding changes in the lubricant. The investigation consisted of steploading wear studies by a pin or disk tribometer, the effects on wear related to wetting by contact angle and surface tension measurements of various liquid systems, the chemical bonding changes between lubricant and TCP chromatographic analysis, and by determining the reaction between the TCP and metal surfaces through wear scar analysis by Auger emission spectroscopy (AES). The steploading curve for the base fluid alone shows rapid increase of wear rate with load. The steploading curve for the base fluid in presence of 4.25 percent by volume TCP under dry air purge has shown a great reduction of wear rate with all loads studied. It has also been found that the addition of 4.25 percent by volume TCP plus 0.33 percent by volume water to the base lubricant under N2 purge also greatly reduces the wear rate with all loads studied. AES surface analysis reveals a phosphate type wear resistant film, which greatly increases load-bearing capacity, formed on the iron disk. Preliminary chromatographic studies suggest that this film forms either because of ester oxidation or TCP degradation. Wetting studies show direct correlation between the spreading coefficient and the wear rate.

Ghose, Hiren M.↗

Continuum theories for fluid-particle flows: Some aspects of lift forces and turbulence

A general framework is outlined for the modeling of fluid particle flows. The momentum exchange between the constituents embodies both lift and drag forces, constitutive equations for which can be made explicit with reference to known single particle analysis. Relevant results for lift are reviewed, and invariant representations are posed. The fluid and particle velocities and the particle volume fraction are then decomposed into mean and fluctuating parts to characterize turbulent motions, and the equations of motion are averaged. In addition to the Reynolds stresses, further correlations between concentration and velocity fluctuations appear. These can be identified with turbulent transport processes such as eddy diffusion of the particles. When the drag force is dominant, the classical convection dispersion model for turbulent transport of particles is recovered. When other interaction forces enter, particle segregation effects can arise. This is illustrated qualitatively by consideration of turbulent channel flow with lift effects included.

Mctigue, David F.↗