Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerating cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Ingot Nb based SRF technology for the International Linear Collider

The International Linear Collider (ILC) is anticipated to be built as the next energy-frontier electron-positron colliding accelerator with a global effort in particle physics. Niobium based Superconducting Radio-Frequency (SRF) technology is required to provide beam-accelerating structure with elliptical cavity strings to linearly accelerate the electron and positron beams up to 250 GeV and to realize a center-of-mass energy of 500 GeV in collisions. The accelerator design and R&D efforts progressed, and the ILC Technical Design Report (ILC-TDR) was published in 2013. Niobium will take a critical role to generate electric field gradient with a frequency of 1.3 GHz, for accelerating the beam with the best efficiency, in energy balance, using RF superconductivity. This paper discusses a technical approach to provide Nb material (ingot) and thin disks for producing the elliptical cavity structure, with direct slicing from Nb ingot having sufficiently optimized purity and residual resistance ration (RRR) necessary for the ILC SRF cavities.

43 PARTICLE ACCELERATORS↗

Tests of a tuner for a 325 MHz SRF spoke resonator

Fermilab is developing 325 MHz SRF spoke cavities for the proposed Project X. A compact fast/slow tuner has been developed for final tuning of the resonance frequency of the cavity after cooling down to operating temperature and to compensate microphonics and Lorentz force detuning [2]. The modified tuner design and results of 4.5K tests of the first prototype are presented. The performance of lever tuners for the SSR1 spoke resonator prototype has been measured during recent CW and pulsed tests in the Fermilab SCTF. The tuner met or exceeded all design goals and has been used to successfully: (1) Bring the cold cavity to the operating frequency; (2) Compensate for dynamic Lorentz force detuning; and (3) Compensate for frequency detuning of the cavity due to changes in the He bath pressure.

43 PARTICLE ACCELERATORS↗

High current SRF cavity design for SPL and eRHIC

A high current five-cell Nb superconducting cavity, called BNL3 cavity, was optimized and designed for the SPL and eRHIC. For the fundamental mode, the optimization process aimed at maximizing the R/Q of the fundamental mode and the geometry factor G under an acceptable RF field ratio level of B{sub peak}/E{sub acc} and E{sub peak}/E{sub acc}. For higher order modes, the optimization is to lower (R/Q)Q{sub ext} for dipole and quadrupole modes to suppress the beam-break-up (BBU). To extract the HOM power out of the cavity, the BNL3 cavity employs a larger beam pipe, allowing the propagation of HOMs, but not the fundamental mode. Six HOM couplers (three at each end) are used to extract large HOM power. To avoid the cross-talk between cavities, tapers are employed between the cavities. This paper presents the design of the BNL3 cavity, end groups and BBU simulation results.

43 PARTICLE ACCELERATORS↗

Automated Hydroforming of Seamless Superconducting RF Cavity

We are studying the possibility of automated hydroforming process for seamless superconducting RF cavities. Preliminary hydroforming tests of three-cell cavities from seamless tubes made of C1020 copper have been performed. The key point of an automated forming is to monitor and strictly control some parameters such as operation time, internal pressure and material displacements. Especially, it is necessary for our studies to be able to control axial and radial deformation independently. We plan to perform the forming in two stages to increase the reliability of successful forming. In the first stage hydroforming by using intermediate constraint dies, three-cell cavities were successfully formed in less than 1 minute. In parallel, we did elongation tests on cavity-quality niobium and confirmed that it is possible to achieve an elongation of >64% in 2 stages that is required for our forming of 1.3 GHz cavities.

36 MATERIALS SCIENCE↗

Finite Element Modeling of Electrochemical Polishing of Niobium in Hydrofluoric-Sulfuric Acid Electrolyte

Niobium (Nb) used in superconducting radio-frequency cavities requires smooth surface to achieve optimal performance. In this work, a finite element model that coupled electrochemistry, heat transfer, and fluid dynamics was developed to investigate the electrochemical polishing mechanisms of Nb, using experimentally measured polarization results of coupon samples as validations. The current and potential distribution, oxide growth kinetics of Nb in a complex cavity geometry was investigated as a function of temperature and coolant flow. A low temperature coolant with intermediate flow rate was found to reduce surface current and ensure oxide uniformity. These results could shed light on the design of future particle accelerators.

SRF accelerator cavity↗

Mechanical Properties of Niobium Cavities

The mechanical stability of bulk Nb cavity is an important aspect to be considered in relation to cavity material, geometry and treatments. Mechanical properties of Nb are typically obtained from uniaxial tensile tests of small samples. In this contribution we report the results of measurements of the resonant frequency and local strain along the contour of single-cell cavities made of ingot and fine-grain Nb of different purity subjected to increasing uniform differential pressure, up to 6 atm. Measurements have been done on cavities subjected to different heat treatments. Good agreement between finite element analysis simulations and experimental data in the elastic regime was obtained with a single set of values of Young’s modulus and Poisson’s ratio. The experimental results indicate that the yield strength of medium-purity ingot Nb cavities is higher than that of fine-grain, high-purity Nb.

36 MATERIALS SCIENCE↗

Optimization Studies for Radiation Shielding of a Superconducting RF Cavity Test Facility

Test facilities for high-gradient superconducting RF cavities must be shielded for particle radiation, which is generated by field emitted electrons in the cavities. A major challenge for the shielding design is associated with uncertainty in modeling the field emission. In this work, a semi-empirical method that allows us to predict the intensity of the generated field emission is described. Spatial, angular and energy distributions of the generated radiation are calculated with the FISHPACT code. The Monte Carlo code MARS15 is used for modeling the radiation transport in matter. The detailed distributions of the generated field emission are used for studies with 9-cell 1.3 GHz superconducting RF cavities in the Fermilab Vertical Cavity Test Facility. This approach allows us to minimize the amount of shielding inside cryostat which is an essential operational feature.

43 PARTICLE ACCELERATORS↗

The RF performance of cavity made from defective niobium material determined by Eddy Current Scanning

Eddy current scanning (ECS) has been used to screen niobium sheets to avoid defective material being used in costly cavity fabrication. The evaluation criterion of this quality control tool is not well understood. Past surface studies showed some features were shallow enough to be removed by chemical etching. The remaining features were identified to be small number of deeper inclusions, but mostly unidentifiable features (by chemical analysis). A real cavity made of defective niobium material has been tested. The cavity achieved high performance with comparable results to the cavities made from defect free cavities. Temperature mapping could help to define the control standard clearly.

43 PARTICLE ACCELERATORS↗

Observations of Short-Range Wakefield Effects in TESLA-Type Superconducting RF Cavities

The Fermilab Accelerator Science and Technology (FAST) facility has a unique configuration of a photocathode rf gun beam injecting two TESLA-type single cavities (CC1 and CC2) in series prior to the cryomodule. To investigate short-range wakefield effects, we have steered the beam to minimize the signals in the higher-order mode (HOM) detectors of CC1 and CC2 for a baseline, and then used a vertical corrector between the two cavities to steer the beam off axis at an angle into CC2. A Hamamatsu synchroscan streak camera viewing a downstream OTR screen provided an image of y-t effects within the micropulses with ~10-micron spatial resolution and 2-ps temporal resolution. At 500 pC/b, 50 b, and 4 mrad off-axis steering into CC2, we observed an ~ 100-micron head-tail centroid shift in the streak camera image y(t)-profiles. This centroid shift value is 5 times larger than the observed HOM-driven centroid oscillation within the macropulse and is consistent with a calculated short-range wakefield effect. Additional results for kick-angle compensations will be presented.

43 PARTICLE ACCELERATORS↗

Observations of Short-Range Wadefield Effects in Tesla-Type Superconducting RF Cavities

The Fermilab Accelerator Science and Technology (FAST) facility has a unique configuration of a photocathode rf gun beam injecting two TESLA-type single cavities (CC1 and CC2) in series prior to the cryomodule. To investigate short-range wakefield effects, we have steered the beam to minimize the signals in the higher-order mode (HOM) detectors of CC1 and CC2 for a baseline, and then used a vertical corrector between the two cavities to steer the beam off axis at an angle into CC2. A Hamamatsu synchroscan streak camera viewing a downstream OTR screen provided an image of y-t effects within the micropulses with ~10-micron spatial resolution and 2-ps temporal resolution. At 500 pC/b, 50 b, and 4 mrad off-axis steering into CC2, we observed an ~ 100-micron head-tail centroid shift in the streak camera image y(t)-profiles. This centroid shift value is 5 times larger than the observed HOM-driven centroid oscillation within the macropulse and is consistent with a calculat ed short-range wakefield effect. Additional results for kick-angle compensations will be presented.

43 PARTICLE ACCELERATORS↗

Observations of Long-Range and Short-Range Wakefield Effects on Electron-Beam Dynamics in TESLA-type SCRF Cavities

The Fermilab Accelerator Science and Technology (FAST) facility has a unique configuration of a photocathode rf gun beam injecting two TESLA-type single cavities (CC1 and CC2) in series prior to the cryomodule. Beam propagation off axis in these cavities can result in both long-range and short-range transverse wakefields which can lead to emittance dilution within the macropulses and micropulses, respectively. Two configurations of a Hamamatsu C5680 streak camera viewing a downstream OTR screen were utilized to track centroid shifts during the macropulse (framing mode) for the long-range case and during the micropulse for the short-range case (~10-micron spatial resolution and 2-ps temporal resolution). Steering off axis before CC1, resulted in a 100-kHz bunch centroid oscillation within the macropulse that was detected by the downstream rf BPMs and the streak camera*. At 500 pC/b, 50b, and 4-mrad off-axis vertical steering into CC2, we observed an ~ 100-micron head -tail centroid shift in the streak camera image y(t) profiles which we attributed to a short-range wakefield effect. Additional results for kick-angle compensations and model results will be presented.

43 PARTICLE ACCELERATORS↗

Highly efficient acceleration and collimation of high-density plasma using laser-induced cavity pressure

An efficient scheme of acceleration and collimation of dense plasma is proposed and examined. In the scheme, a target placed in a cavity coupled with a guiding channel is irradiated by a laser beam introduced into the cavity through a hole and accelerated along the channel by the pressure of the ablating plasma confined in the cavity. Using 1.315 mum, 0.3 ns laser pulse of energy up to 200 J and a thin CH target, it was shown that the energetic efficiency of acceleration in this scheme is an order of magnitude higher than in the case of conventional ablative acceleration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conceptual design of the FRIB cryogenic system

The Facility for Rare Isotope Beams (FRIB) is a new nuclear science facility funded by the DOE Office of Science and Michigan State University (MSU). FRIB is currently under design and will be located on the MSU campus. The centerpiece of FRIB is a heavy ion linac utilizing superconducting RF cavities and magnets which in turn requires a large cryogenic system. The cryogenic system consists of a commercially produced helium refrigeration plant and an extensive distribution system. Superconducting components will operate at both 4.5 K and 2 K. This paper describes the conceptual design of the system including the expected heat loads and operating modes. The strategy for procuring a custom turnkey helium refrigeration plant from industry, an overview of the distribution system, the interface of the cryogenic system to the conventional facilities and the project schedule are also described.

43 PARTICLE ACCELERATORS↗

Improving vacuum performance in the warm linac of the Spallation Neutron Source

The Spallation Neutron Source is an accelerator-based neutron source built and operated by the U.S. Department of Energy in Oak Ridge, Tennessee. With over 10 years of operation at 1 MW of power and above, shortcomings have been identified in the original vacuum pumping scheme for the drift tube and the coupled cavity linear accelerator sections. In this article, the vacuum performance for these systems is reviewed and the major areas of concern are discussed. The changes to the vacuum system are examined and the final design is described. Finally, the performance impact of these changes after a year of operation with the new vacuum system is presented.

47 OTHER INSTRUMENTATION↗

Cold cavity analysis for 35 GHz gyrotron interaction cavity using free space method

The interaction cavity simulated, designed and fabricated for the 35 GHz gyrotron is verified experimentally. Free space method for the Q value and resonant frequency measurement is used in the experiments. The WR22 waveguide based antenna system, Agilent Vector Network Analyzer are used as the experimental set-up in the cavity measurement. The simulation results for the same cavity are also obtained by using the electromagnetic simulator MAGIC for the comparison. (author)

43 PARTICLE ACCELERATORS↗

1.3 GHz superconducting RF cavity program at Fermilab

At Fermilab, 9-cell 1.3 GHz superconducting RF (SRF) cavities are prepared, qualified, and assembled into cryomodules (CMs) for Project X, an International Linear Collider (ILC), or other future projects. The 1.3 GHz SRF cavity program includes targeted R&D on 1-cell 1.3 GHz cavities for cavity performance improvement. Production cavity qualification includes cavity inspection, surface processing, clean assembly, and one or more cryogenic low-power CW qualification tests which typically include performance diagnostics. Qualified cavities are welded into helium vessels and are cryogenically tested with pulsed high-power. Well performing cavities are assembled into cryomodules for pulsed high-power testing in a cryomodule test facility, and possible installation into a beamline. The overall goals of the 1.3 GHz SRF cavity program, supporting facilities, and accomplishments are described.

43 PARTICLE ACCELERATORS↗