Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Integrated system modeling analysis of a cryogenic multi-cell deflecting-mode cavity resonator

A deflecting mode cavity is the integral element for six-dimensional phase-space beam control in bunch compressors and emittance transformers at high energy beam test facilities. RF performance of a high-Q device is, however, highly sensitive to operational conditions, in particular in a cryo-cooling environment. Using analytic calculations and RF simulations, we examined cavity parameters and deflecting characteristics of TM{sub 110,π} mode of a 5 cell resonator in a liquid nitrogen cryostat, which has long been used at the Fermilab A0 Photoinjector (A0PI). The sensitivity analysis indicated that the cavity could lose 30%–40% of deflecting force due to defective input power coupling accompanying non-uniform field distribution across the cells with 40 ∼ 50 MeV electron beam and 70–80 kW klystron power. Vacuum-cryomodules of the 5 cell cavity are planned to be installed at the Fermilab Advanced Superconducting Test Accelerator facility. Comprehensive modeling analysis integrated with multi-physics simulation tools showed that RF loading of 1 ms can cause a ∼5 K maximum temperature increase, corresponding to a ∼4.3 μm/ms deformation and a 1.32 MHz/K maximum frequency shift. The integrated system modeling analysis will improve design process of a high-Q cavity with more accurate prediction of cryogenic RF performance under a high power pulse operation.

43 PARTICLE ACCELERATORS↗

The effect of the H{sub 2} density on the electron energy distribution in H{sup −} ion sources

The electron energy distribution in H{sup −} ion sources is studied. By three-dimensional Monte Carlo simulations (3D-MCC) and cross sections of collisions, the crucial collisions in the JAEA 10A are chosen to develop theoretical models for the low electron temperature and the high electron temperature, respectively. The effects of the H{sub 2} density on the low electron temperature and the high electron temperature in H{sup −} ion sources are predicted with analytic expressions and verified by 3D-MCC. The results show that both the low and high electron temperatures become lower while n{sub H2} increases.

43 PARTICLE ACCELERATORS↗

A compact, versatile low-energy electron beam ion source

A new compact Electron Beam Ion Source, the Dresden EBIT-LE, is introduced as an ion source working at low electron beam energies. The EBIT-LE operates at an electron energy ranging from 100 eV to some keV and can easily be modified to an EBIT also working at higher electron beam energies of up to 15 keV. We show that, depending on the electron beam energy, electron beam currents from a few mA in the low-energy regime up to about 40 mA in the high-energy regime are possible. Technical solutions as well as first experimental results of the EBIT-LE are presented. In ion extraction experiments, a stable production of low and intermediate charged ions at electron beam energies below 2 keV is demonstrated. Furthermore, X-ray spectroscopy measurements confirm the possibility of using the machine as a source of X-rays from ions excited at low electron energies.

43 PARTICLE ACCELERATORS↗

Precision phase control for the radio frequency system of K500 superconducting cyclotron at Variable Energy Cyclotron Centre, Kolkata

Variable Energy Cyclotron Centre (VECC) has commissioned K500 Superconducting cyclotron (SCC) based on MSU and Texas A and M university cyclotrons. The radio frequency (RF) system of SCC has been commissioned with the stringent requirement of various RF parameters. The three-phase RF system of Superconducting cyclotron has been developed in the frequency range 9–27 MHz with amplitude and phase stability of 100 ppm and ±0.1°, respectively. The phase control system has the option to change the relative phase difference between any two RF cavities and maintain the phase stability within ±0.1° during round-the-clock cyclotron operation. The said precision phase loop consists of both analogue In-phase/Quadrature modulator to achieve faster response and also Direct Digital Synthesis based phase shifter to achieve wide dynamic range as well. This paper discusses detail insights into the various issues of phase control for the K500 SCC at VECC, Kolkata.

43 PARTICLE ACCELERATORS↗

Permanent magnet electron beam ion source/trap systems with bakeable magnets for improved operation conditions

The magnetic system of a Dresden electron beam ion source (EBIS) generating the necessary magnetic field with a new type of permanent magnet made of high energy density NdFeB-type material operable at temperatures above 100 °C has been investigated and tested. The employment of such kind of magnets provides simplified operation without the time-consuming installation and de-installation procedures of the magnets for the necessary baking of the ion source after commissioning and maintenance work. Furthermore, with the use of a new magnetization technique the geometrical filling factor of the magnetic Dresden EBIS design could be increased to a filling factor of 100% leading to an axial magnetic field strength of approximately 0.5 T exceeding the old design by 20%. Simulations using the finite element method software Field Precision and their results compared with measurements are presented as well. It could be shown that several baking cycles at temperatures higher than 100 °C did not change the magnetic properties of the setup.

43 PARTICLE ACCELERATORS↗

Fluctuation of an ion beam extracted from an AC filament driven Bernas-type ion source

Argon ion beam fluctuation from an AC filament driven Bernas-type ion source is observed. The ion beam was measured by an 8 measurement elements beam profile monitor. The amplitude of the beam current fluctuation stayed in the same level from 100 Hz to 1 kHz of the filament heating frequency. The beam current fluctuation frequency measured by the beam profile monitor was equal to the frequency of the AC filament operation. The fluctuation amplitudes of the beam current by AC operation were less than 7% and were in the same level of the DC operation.

43 PARTICLE ACCELERATORS↗

A real-time intercepting beam-profile monitor for a medical cyclotron

There is a lack of real-time continuous beam-diagnostic tools for medical cyclotrons due to high power deposition during proton irradiation. To overcome this limitation, we have developed a profile monitor that is capable of providing continuous feedback about beam shape and current in real time while it is inserted in the beam path. This enables users to optimize the beam profile and observe fluctuations in the beam over time with periodic insertion of the monitor.

43 PARTICLE ACCELERATORS↗

Improving efficiency of negative ion production in ion source with saddle antenna

Extraction of negative ions from a saddle antenna radio-frequency surface plasma source is considered. Several versions of new plasma generators with different antennas and magnetic field configurations were tested in the smal Oak Ridge National Laboratory Spallation Neutron Source Test Stand. The efficiency of positive ion generation in plasma has been improved to 200 mA/cm{sup 2} kW from 2.5 mA/cm{sup 2} kW. A small oven was developed for cesiation by cesium compounds and alloy decomposition. After cesiation, a current of negative ions to the collector was increased from 1 mA to 10 mA with 1.5 kW RF power in the plasma and longitudinal magnetic field B{sub l} ∼ 250 G. The specific efficiency of H{sup −} production was increased to 20 mA/cm{sup 2} kW from 2.5 mA/cm{sup 2} kW.

43 PARTICLE ACCELERATORS↗

Numerical simulation of ion charge breeding in electron beam ion source

The Electron Beam Ion Source particle-in-cell code (EBIS-PIC) tracks ions in an EBIS electron beam while updating electric potential self-consistently and atomic processes by the Monte Carlo method. Recent improvements to the code are reported in this paper. The ionization module has been improved by using experimental ionization energies and shell effects. The acceptance of injected ions and the emittance of extracted ion beam are calculated by extending EBIS-PIC to the beam line transport region. An EBIS-PIC simulation is performed for a Cs charge-breeding experiment at BNL. The charge state distribution agrees well with experiments, and additional simulation results of radial profiles and velocity space distributions of the trapped ions are presented.

43 PARTICLE ACCELERATORS↗

Effect of non-uniform slow wave structure in a relativistic backward wave oscillator with a resonant reflector

This paper provides a fresh insight into the effect of non-uniform slow wave structure (SWS) used in a relativistic backward wave oscillator (RBWO) with a resonant reflector. Compared with the uniform SWS, the reflection coefficient of the non-uniform SWS is higher, leading to a lower modulating electric field in the resonant reflector and a larger distance to maximize the modulation current. Moreover, for both types of RBWOs, stronger standing-wave field takes place at the rear part of the SWS. In addition, besides Cerenkov effects, the energy conversion process in the RBWO strongly depends on transit time effects. Thus, the matching condition between the distributions of harmonic current and standing wave field provides a profound influence on the beam-wave interaction. In the non-uniform RBWO, the region with a stronger standing wave field corresponds to a higher fundamental harmonic current distribution. Particle-in-cell simulations show that with a diode voltage of 1.02 MV and beam current of 13.2 kA, a microwave power of 4 GW has been obtained, compared to that of 3 GW in the uniform RBWO.

43 PARTICLE ACCELERATORS↗

Self-focusing of a high current density ion beam extracted with concave electrodes in a low energy region around 150 eV

Spontaneous self-focusing of ion beam with high current density (J{sub c} ∼ 2 mA/cm{sup 2}, I{sub b} ∼ 65 mA) in low energy region (∼150 eV) is observed in a hydrogen ion beam extracted from an ordinary bucket type ion source with three electrodes having concave shape (acceleration, deceleration, and grounded electrodes). The focusing appears abruptly in the beam energy region over ∼135–150 eV, and the J{sub c} jumps up from 0.7 to 2 mA/cm{sup 2}. Simultaneously a strong electron flow also appears in the beam region. The electron flow has almost the same current density. Probably these electrons compensate the ion space charge and suppress the beam divergence.

43 PARTICLE ACCELERATORS↗

A double-beam magnetron-injection gun for third-harmonic continuous wave 1-THz gyrotron

The concept of a continuous wave 1-kW/1-THz gyrotron operated at the third cyclotron harmonic of the transverse electric TE{sub 9,7} operating mode has been developed. To suppress the mode competition effects in a terahertz gyrotron, we propose a scheme with two generating helical electron beams (HEBs) formed in a double-beam triode magnetron-injection gun (MIG), where both emitters of the electron beams are located on a common cathode of the conventional MIG. An optimal geometry of the MIG electrodes is found. It is shown that in a proposed scheme two HEBs having close pitch factors and a moderate velocity spread can be formed. This makes them suitable for high-efficiency single-mode generation in the high frequency gyrotron at high harmonic.

43 PARTICLE ACCELERATORS↗

Radioactive ion beam transportation for the fundamental symmetry study with laser-trapped atoms

The search for the violation of the fundamental symmetry in a radioactive atom is the promising candidate for precision tests of the standard model and its possible extensions. The subtle signal arising from the symmetry violation is enhanced in heavy atoms, such as a francium (Fr). To realize high precision measurements, a large amount of radioactive isotopes is required. The Fr is produced via a nuclear fusion reaction using a melted gold target with a {sup 18}O primary beam at Cyclotron and Radioisotope Center, Tohoku University. The maximum extraction efficiency of the Fr ion was achieved at approximately 35%. The beam line consists of an electrostatic deflector, three electrostatic quadrupole triplets to the measurement area at 10 m away from the reaction point, and several beam diagnosis systems. We optimized parameters of the beam line.

43 PARTICLE ACCELERATORS↗

Ionization efficiency studies with charge breeder and conventional electron cyclotron resonance ion source

Radioactive Ion Beams play an increasingly important role in several European research facility programs such as SPES, SPIRAL1 Upgrade, and SPIRAL2, but even more for those such as EURISOL. Although remarkable advances of ECRIS charge breeders (CBs) have been achieved, further studies are needed to gain insight on the physics of the charge breeding process. The fundamental plasma processes of charge breeders are studied in the frame of the European collaboration project, EMILIE, for optimizing the charge breeding. Important information on the charge breeding can be obtained by conducting similar experiments using the gas mixing and 2-frequency heating techniques with a conventional JYFL 14 GHz ECRIS and the LPSC-PHOENIX charge breeder. The first experiments were carried out with noble gases and they revealed, for example, that the effects of the gas mixing and 2-frequency heating on the production of high charge states appear to be additive for the conventional ECRIS. The results also indicate that at least in the case of noble gases the differences between the conventional ECRIS and the charge breeder cause only minor impact on the production efficiency of ion beams.

43 PARTICLE ACCELERATORS↗

Multiple species beam production on laser ion source for electron beam ion source in Brookhaven National Laboratory

Extracted ion beams from the test laser ion source (LIS) were transported through a test beam transport line which is almost identical to the actual primary beam transport in the current electron beam ion source apparatus. The tested species were C, Al, Si, Cr, Fe, Cu, Ag, Ta, and Au. The all measured beam currents fulfilled the requirements. However, in the case of light mass ions, the recorded emittance shapes have larger aberrations and the RMS values are higher than 0.06 π mm mrad, which is the design goal. Since we have margin to enhance the beam current, if we then allow some beam losses at the injection point, the number of the single charged ions within the acceptance can be supplied. For heaver ions like Ag, Ta, and Au, the LIS showed very good performance.

43 PARTICLE ACCELERATORS↗

Design study of a 17.3 GHz electron cyclotron resonance (ECR) ion source at Louvain-la-Neuve

The Cyclotron Resources Center of the Louvain-la-Neuve University is developing a new electron cyclotron resonance ion source to increase the energy of the accelerated beam by injection of higher charge state ions into the cyclotron. The design of the source is based on a 17.3 GHz frequency and classical coils to produce the axial field. The field reaches 2 T at the injection side and 1.2 T at extraction. The total power consumption for the coils is limited to 80 kW. The design features of the source are presented.

43 PARTICLE ACCELERATORS↗

A transverse emittance and acceptance measurement system in a low-energy beam transport line

A transverse beam emittance and acceptance measurement system has been developed to visualize the relationship between the injected beam emittance and the acceptance of a cyclotron. The system is composed of a steering magnet, two pairs of slits to limit the horizontal and vertical phase-space, a beam intensity detector just behind the slits for the emittance measurement, and a beam intensity detector in the cyclotron for the acceptance measurement. The emittance is obtained by scanning the slits and measuring the beam intensity distribution. The acceptance is obtained by measuring the distribution of relative beam transmission by injecting small emittance beams at various positions in a transverse phase-space using the slits. In the acceptance measurement, the beam from an ion source is deflected to the defined region by the slits using the steering magnet so that measurable acceptance area covers a region outside the injection beam emittance. Measurement tests were carried out under the condition of accelerating a beam of {sup 16}O{sup 6+} from 50.2 keV to 160 MeV. The emittance of the injected beam and the acceptance for accelerating and transporting the beam to the entrance of the extraction deflector were successfully measured. The relationship between the emittance and acceptance is visualized by displaying the results in the same phase-plane.

43 PARTICLE ACCELERATORS↗

Cryogenic performance of a cryocooler-cooled superconducting undulator

A cryocooler-cooled superconducting undulator has been installed and operated with beam at the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The device consists of a dual-core 42-pole magnet structure that is cooled to 4.2 K with a system of four cryocoolers operating in a zero-boil-off configuration. This effort represents the culmination of a development program to establish concept feasibility and evaluate cryostat design and cryocooler-based refrigeration. Cryostat performance is described including cool-down/warm-up, steady-state operation, cooling margin, and the impact of beam during operation in the APS storage ring. Plans for future devices with longer magnets, which will incorporate lessons learned from the development program, are also discussed.

43 PARTICLE ACCELERATORS↗