Search NASA⌕ Search

SEARCH · Search NASA

Results for “Active cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Assessment of BISON capabilities for component-level prediction of tritium transport in fusion and fission applications

Here we assessed the hydrogen migration and redistribution model implemented in the BISON fuel performance code for component-level tritium transport applications in fusion and fission example scenarios. We developed BISON models of an ITER heat exchanger, light water reactor fuel cladding, and a fluoride salt cooled high temperature reactor heat exchanger. Reasonable agreement between reported values in reference studies and BISON predictions demonstrated the ability of the BISON models to predict tritium transport behavior through steel materials. Next, sensitivity and uncertainty analysis was used to understand key parameter sensitivities within the BISON model for evaluation of tritium migration and redistribution. . The sensitivity analysis showed that the diffusivity activation energy was the most important parameter and that the heat of transport was the least important parameter for tritium migration in steels. Overall, the capabilities of the BISON code for component level modeling of tritium transport are promising.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CACTI ARM Aerial Facility Measurements of Ice Nucleating Particles

The dataset comprises measures, using Colorado State University's Ice Spectrometer (IS, an immersion freezing device with a range from 0°C down to -26 to -29°C) of atmospheric ice nucleating particle (INP) concentrations taken on the Atmospheric Radiation Measurement (ARM) program Aerial Facilty (AAF) G-1 aircraft. INP measurements on the G-1 were collected from varied altitudes on different flights over the region of the Sierras de Córdoba mountain range of north-central Argentina, centred over ARM's Mobile Facility (AMF-1) near Villa Yacanto, where ground-based INP measures were being taken concurrently. Both studies took place as part of the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) Experiment. A filter sampling system was deployed on the G-1 to collect aerosol particles for post-processing of INPs collected on filters (measuring their immersion freezing ability) once returned to Colorado State University (CSU). Filter holders used were pre-cleaned aluminum in-line units loaded with pre-cleaned and pre-sterilized 47 mm dia. Nuclepore polycarbonate filters (0.2 mm pore size). Filters were drawn for varied times, resulting in varied volumes collected (51 to 1667 SL). Mass flow rate was recorded in real-time so that total sampled volume (at standard temperature and pressure) could be determined. A total of 34 sample filters were collected over the IOP, including 5 blanks. Filters were stored at -20°C freezer prior to frozen return to Colorado State University (CSU). . Processing to obtain spectra of INP number concentration active via the immersion freezing mechanism versus temperature was conducted using CSU's IS instrument (McCluskey et al., 2018). For measurment of INPs, collected aerosol particles were re-suspended in 7 mL of 0.02 µm-filtered deionized water. Aliquots of each suspension, and serial dilutions, were dispensed into trays which were fit into aluminum blocks in the IS. Samples are cooled at 0.33°C min-1 and the freezing temperatures of wells recorded automatically. Cumulative INP concentrations were determined by first calculating the INPs per mL of suspension based on Vali (1971) and then converting to concentration per standard liter of air using the proportion of the total liquid sample dispensed and the air sample volumes. Aliquots of suspensions from selected samples were also heat treated (95°C for 20 min) to denature and deactivate biological INPs, and digested in 10% H2O2 at 95°C under UV-B to remove all organic carbon INPs. McCluskey, C. S., J. Ovadnevaite, M. Rinaldi, J. Atkinson, F. Belosi, D. Ceburnis, S. Marullo, T. C. J. Hill, U. Lohmann, Z. A. Kanji, C. O’Dowd, S. M. Kreidenweis, P. J. DeMott, 2018: Marine and Terrestrial Organic Ice Nucleating Particles in Pristine Marine to Continentally-Influenced Northeast Atlantic Air Masses, Journal of Geophysical Research: Atmospheres, 123, 6196–6212, https://doi.org/10.1029/2017JD028033. Vali, G., 1971: Quantitative evaluation of experimental results on the heterogeneous freezing nucleation of supercooled liquids. J. Atmos. Sci., 28, 402–409.

54 ENVIRONMENTAL SCIENCES↗

Spontaneous Symmetry–Breaking of Nonequilibrium Steady–States Caused by Nonlinear Electrical Transport

Negative differential resistance (NDR) in certain materials has been attributed to spontaneous emergence of symmetry-breaking electrical current density localization from a previously homogeneous distribution, which is postulated to occur due to the nonequilibrium thermodynamic force of minimization of entropy production. However, this phenomenon has not been quantitatively predicted based on intrinsic material properties and an applied electrical stimulus. Herein an instability criterion is derived for localization of current density and temperature from a thermal fluctuation in a parallel conductor model of a thin film that is subject to Newton's law of cooling. The conditions for steady–state electro-thermal localization is predicted, verifying a decrease in entropy production upon localization. Electro-thermal localization accompanied by a decrease of entropy production is confirmed in a multiphysics simulation of current flow in a thin film. The instability criterion predicts conditions for spontaneous current density localization, relating symmetry breaking fundamentally to dynamical instability via Local Activity theory.

36 MATERIALS SCIENCE↗

Production and Performance of High Sulfur Concentration Waste Glasses (FY21)

In FY21 Savannah River National Laboratory (SRNL) was tasked to investigate the practical aspects of low activity waste (LAW) glass production with high sulfur loading for the Office of River Protection (ORP). Relationships between sulfur solubility, retention, and melter resonance need to be evaluated to refine waste loading limits and the super saturated melting (triple melt, grind, and wash) methodology. The impact of high sulfur concentration on durability and phase stability (crystallization and liquid-liquid immiscibility) during slow cooling also needs to be further evaluated. To accomplish this, SRNL proposed scaled melter testing using simulants with matched physicochemical properties to melter feed, as opposed to laboratory reagents. This type of testing is expected to validate applicability to design parameters and functional criteria expected during unit operations. This work was expected to commence in FY21, with the first melter tests being performed near the end of the FY. However, reduced access to Savannah River Site and personnel availability during the COVID-19 pandemic significantly reduced the amount of time and resources available to perform the task. This report documents the experimental plan and progress towards this task. The following is a summarized list of scheduled testing that will be performed on feed, condensate, cold cap and glass: 1) Melter runs; 2) Product consistency test (PCT); 3) Inductively coupled plasma optical emission spectroscopy (ICP-OES); and 4) Optical (OM) and scanning electron microscopy (SEM).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Performance of Neutron Sensor Qualification Device

The neutron sensor qualification device was developed to provide a temperature-controlled environment for neutron sensors and dosimetry, enabling irradiation in a neutron field at the Armed Forces Radiobiology Research Institute (AFRRI) TRIGA reactor facility. The device, constructed from low-activation and low neutron cross-section materials, features a modular tube furnace design with three independently controlled heating zones for controlling axial temperature distribution. Laboratory testing validated the device's thermal performance, including uniform temperature distribution with less than 6°C variation across the central region, a steady-state operational temperature of 350°C achieved in approximately 3 hours, and a cooling time constant of 3.5 hours. External surface temperatures remained safe for handling, with the surrounding aluminum structure remaining at ambient conditions. The results confirm the device’s suitability for neutron sensor qualification experiments, with potential for future operation at higher temperatures and further optimization of performance.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

AEROICESTUDY-Colorado State University Ice Spectrometer

The dataset comprises measures, using Colorado State University's Ice Spectrometer (IS, an immersion freezing device with a range from 0 °C down to -26 to -29 °C) of atmospheric ice nucleating particle (INP) concentrations taken at ARM's Southern Great Plains (SGP) Site Guest Instrument Facility (GIF), in Lamont, Oklahoma, during the Aerosol-Ice Formation Closure Pilot Study (AEROICESTUDY). A filter sampler was mounted approximately 6 m above ground level atop the GIF rooftop platform. Single-use filter units open to the atmosphere fitted with pre-cleaned and pre-sterilized, 47-mm diameter Nuclepore polycarbonate filters were used. Filters were typically drawn for either a full day period (9AM-5PM CDT) or broken up into morning (9AM-12PM CDT) and afternoon (1PM-5PM CDT) periods. Additionally, 4 overnight filters were taken (6PM-8AM CDT). The volume of air filtered was typically between 3000 and 8000 standard liters for daily samples. After collection, filters were stored at -20 °C until processed. Initial processing to obtain spectra of INP number concentration active via the immersion freezing mechanism versus temperature was conducted using CSU's IS instrument (McCluskey et al., 2018). For measurement of INPs, collected aerosol particles were re-suspended in 8 mL of 0.1 µm-filtered deionized (DI) water. Aliquots of each suspension, and serial dilutions, were dispensed into trays which were fit into aluminum blocks in the IS. Samples were cooled at 0.33 °C per min and the freezing temperatures of wells recorded automatically. Cumulative INP concentrations were determined by first calculating the INPs per mL of suspension based on Vali (1971) and then converting to concentration per standard liter of air using the proportion of the total liquid sample dispensed and the air sample volumes. Two-tailed, 95% confidence intervals for binomial sampling were based on Equation 2 from Agresti and Coull (1998). Aliquots of suspensions from selected samples were also heat treated (95 °C for 20 min) to denature and deactiv

54 ENVIRONMENTAL SCIENCES↗

Resistive wall tearing mode disruptions

Abstract This paper deals with resistive wall tearing mode (RWTM) disruptions. RWTMs are closely related to resistive wall modes. RWTMs are tearing modes whose linear and nonlinear behavior is strongly dependent on the resistive wall outside the plasma. The consequence for ITER, is that the thermal quench timescale could be much longer than previously conjectured. Active feedback stabilization is another possible way to mitigate or prevent RWTM disruptions. Simulations of RWTM disruptions are reviewed for DIII-D and MST. MST has a longer resistive wall time than ITER, and disruptions are not observed experimentally when MST is operated as a standard tokamak. Simulations indicate that the RWTM disruption time scale is longer than the experimental shot time. Edge cooling causes contraction of the current profile, which can destabilize RWTMs. The equilibria studied here have the q = 2 rational surface close to the edge of the plasma, and low current density between the q = 2 surface and the wall. A sequence of low edge current model equilibria has major disruptions only for a resistive, not ideal, wall, and edge q ⩽ 3.4 . This is consistent with regimes of tokamak disruptivity, suggesting that tokamak disruptions caused by edge cooling at low edge q could be RWTMs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CACTI ARM Mobile Facility (AMF) Measurements of Ice Nucleating Particles

The dataset comprises measures, using Colorado State University's Ice Spectrometer (IS, an immersion freezing device with a range from 0°C down to -26 to -29°C) of atmosperic ice nucleating particle (INP) concentrations taken on ARM's Mobile Facility (AMF-1) Aerosol Observing System, near Villa Yacanto in central Argentina, during the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) Experiment. A filter sampler was mounted on the AOS trailer (2 m below the AOS inlet). Single-use filter units open to the atmosphere fitted with pre-cleaned and pre-sterilized, 47-mm dia. Nuclepore polycarbonate filters were used. Filters were typically drawn for an 8-hour period, totaling 6000 liters sampled on average. After collection, filters were stored at -20°C until processed. Initial processing to obtain spectra of INP number concentration active via the immersion freezing mechanism versus temperature was conducted using CSU's IS instrument (McCluskey et al., 2018). For measurment of INPs, collected aerosol particles were re-suspended in 7-8 mL of 0.1 µm-filtered deionized (DI) water. Aliquots of each suspension, and serial dilutions, were dispensed into trays which were fit into aluminum blocks in the IS. Samples are cooled at 0.33°C min-1 and the freezing temperatures of wells recorded automatically. Cumulative INP concentrations were determined by first calculating the INPs per mL of suspension based on Vali (1971) and then converting to concentration per standard liter of air using the proportion of the total liquid sample dispensed and the air sample volumes. An aliquot of suspension fro selected samples were also heat treated (95°C for 20 min) to denature and deactivate biological INPs, and another aliquot digested in 10% H2O2 at 95°C under UV-B to remove all organic carbon INPs. McCluskey, C. S., J. Ovadnevaite, M. Rinaldi, J. Atkinson, F. Belosi, D. Ceburnis, S. Marullo, T. C. J. Hill, U. Lohmann, Z. A. Kanji, C. O’Dowd, S. M. Kreidenweis, P. J. DeMott, 2018: Marine and Terrestrial Organic Ice Nucleating Particles in Pristine Marine to Continentally-Influenced Northeast Atlantic Air Masses, Journal of Geophysical Research: Atmospheres, 123, 6196–6212, https://doi.org/10.1029/2017JD028033. Vali, G., 1971: Quantitative evaluation of experimental results on the heterogeneous freezing nucleation of supercooled liquids. J. Atmos. Sci., 28, 402–409.

54 ENVIRONMENTAL SCIENCES↗

Development of a two-zone zero-dimensional mixing model for actively fueled prechamber engines

In this numerical work, a zero-dimensional, two-zone mixing model was developed and validated to capture the mixture preparation process of an actively fueled prechamber engine. The model was developed for ethanol-gasoline fuel blends but is applicable to various fuels of interest relevant to prechamber applications. The model was exercised to demonstrate the effects of boundary conditions, fuel composition, and residual content on the mixture stoichiometry predictions. The 0D model showed reasonable agreement in prechamber equivalence ratio predictions with higher fidelity computational fluid dynamics modeling, but the accuracy of model was constrained to the governing assumptions of the injection process. The modeling assumptions surrounding the non-dimensional injection of mass into the prechamber were scrutinized to identify key areas of model improvement. The results indicate heat transfer effects play a crucial role in the evaporation of the fuel within the confined auxiliary chamber, especially when considering fuels with high latent heat of vaporization. Additionally, the presence of fuel films that collect on the prechamber surfaces complicated the modeled evaporative cooling loses as the modeling suggests the films evaporate primarily by means of conduction from the boundary. Furthermore, the developed model serves as a simplified framework to generate calibration maps of prechamber fueling or run real time as an open loop control strategy such that desired prechamber mixture proportions are effectively targeted.

Zero-dimensional↗

Review of heat transfer enhancement techniques in two-phase flows for highly efficient and sustainable cooling

We show that two-phase internal flow is ubiquitous to many systems due to its ability to transfer large amounts of heat effectively. Recent advances motivated by sustainability have pushed towards augmenting the heat transfer between the tube and the two-phase working fluid. Augmenting heat transfer in two-phase flows enables process intensification, and compactness leading to reduced cost and material consumption. This review investigates the effect of heat transfer enhancement techniques on different fluids including R134a, R407C, R22, etc … The techniques are categorized into passive and active and focus on durable enhancement methods which do not include surface structuring or coating. Passive techniques utilize geometrical and surface modifications to induce better mixing. Several passive techniques are analyzed including fins, inserts, and more. In analyzing these techniques, the effect of changing geometric parameters is studied, and the limitations are highlighted. Further, active techniques that enable heat transfer enhancement through applying power are also investigated. Electrohydrodynamic approaches are analyzed and compared to passive techniques. Additionally, the implications of heat exchange enhancement in the context of global energy are discussed. An energy analysis discretized by the use sector is conducted, with an emphasis on predicting the future potential for renewable and sustainable development. Moreover, although active approaches provide the highest heat transfer enhancement, due to implementation difficulties, passive techniques are more frequently adopted. The review ends with discussion of next-generation heat exchangers which will rely more on additive manufacturing due to its flexibility and reduced cost per part as the technology matures.

Nusselt number↗

Optimization of a Packed Particle Magnetocaloric Refrigerator: A Combined Experimental and Theoretical Study

Magnetocaloric refrigeration has strong potential towards achieving high efficiency hydrogen liquefaction. Optimising parameters such as particle size and operating cycles can have a significant impact on liquefaction performance. Here, this work reports on a room temperature magnetocaloric refrigeration prototype designed with helium as the heat transfer fluid and packed particle Gd 0.8875 Ce 0.1025 Si 0.84 Cr 0.19 as the refrigerant. The temperature spans and cooling power with three different particle sizes at two different operating cycles were measured. A maximum temperature span of 16.7 K and a maximum cooling power of 8.6 W·kg –1 were obtained. Reduction of performance in the faster cycle was observed in larger particles due to insufficient thermal diffusion time and its implications for cryogenic temperatures are discussed. A numerical model was developed based on the experimentally observed variation of the temperature span and cooling power with particle size and cycle duration. This model was then used to study the competing effects of viscous dissipation and thermal diffusion for different particle sizes and cycle durations.

08 HYDROGEN↗

Oxidation behaviors of matrix-grade graphite during water vapor ingress accidents for high temperature gas-cooled reactors

Water ingress into cores of high temperature gas-cooled reactors (HTGRs) can cause serious safety problems in graphitic components, especially for matrix graphite, which is more vulnerable than nuclear graphite. Here in this study, oxidation behaviors of a matrix-grade graphite, ARB-B1, were investigated under simulated water ingress accidental conditions. The oxidation tests were conducted in water vapor/helium mixed atmospheres at elevated temperatures up to 1200 °C. Oxidation rates and activation energy were evaluated by mass loss measurements. The activation energy was 121.5 kJ/mol in the considered temperature range, indicating only one oxidation regime-in-pore diffusion assisted by cracks. The cracks originated from the fabrication process, acting as penetration paths for the oxidant, played an important role in the oxidation behaviors. Ungraphitized binder oxidation occurred at all temperatures, while apparent oxidation of filler particles started from 1100 °C. Moreover, oxidation effects on compressive properties and hardness of the matrix graphite were discussed in terms of oxidized microstructures. This first detailed study on matrix graphite oxidation in water vapor provides important kinetics knowledge and microstructural and mechanical data for accidental scenarios of HTGRs as well as for development of new matrix graphite materials.

36 MATERIALS SCIENCE↗

Manufacturing Science

The Manufacturing Science area of leadership spans the application of fundamental science research and development activities to understand the critical steps in manufacturing processes for the purposes of control and optimization. Although manufacturing is an applied area of research, fundamental science underpins our knowledge of both traditional and transformational manufacturing processes. For example, casting, welding, and many modern additive manufacturing processes that see wide use are broadly classified as solidification processes, with material transitioning from liquid to solid phases upon cooling from higher temperature. However, our understanding of the detailed physics involved in such processes is incomplete, and solidification remains a grand challenge for materials science. To enable adoption of transformative fabrication processes or to accelerate development of traditional ones, it is necessary to develop a detailed mechanistic understanding spanning multiple scales, starting with atomic building blocks (defects, interfaces, composition) and extending all the way up to macroscale performance in moderate and/or extreme environments.

36 MATERIALS SCIENCE↗

System Study: Residual Heat Removal 1998-2020

This report presents an unreliability evaluation of the residual heat removal (RHR) system in two modes of operation (low-pressure injection in response to a large loss-of-coolant accident and in response to post-trip shutdown cooling) at 104 U.S. commercial nuclear reactors. Demand, run hour, and failure data from 1998–2020 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS), formerly the INPO Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10-year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the RHR results.

99 GENERAL AND MISCELLANEOUS↗

Hanford Low-Activity Waste Glass Minor Component Concentration Boundary Expansion

This study investigated the effects of increasing concentrations of minor components on simulated Hanford low-activity waste (LAW) glass properties to allow for LAW glass composition envelope expansion. A test matrix of ten glasses was generated by spiking three previously studied simulated Hanford LAW glass compositions with increasing concentrations of minor component mixes up to a total concentration of 2 wt%. In this study, the ten glasses were fabricated, and key properties were measured including crystal formation after canister centerline cooling (CCC), crystallinity as a function of temperature, density, viscosity, electrical conductivity, glass durability using the Vapor Hydration Test (VHT), product consistency using the Product Consistency Test (PCT), and sulfur solubility. The data from these tests are presented in this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Techno-Economic Analysis of a Concentrating Solar Power Plant Using Redox-Active Metal Oxides as Heat Transfer Fluid and Storage Media

We present results for a one-dimensional quasi-steady-state thermodynamic model developed for a 111.7 MW e concentrating solar power (CSP) system using a redox-active metal oxide as the heat storage media and heat transfer agent integrated with a combined cycle air Brayton power block. In the energy charging and discharging processes, the metal oxide CaAl 0.2 Mn 0.8 O 2.9-δ (CAM28) undergoes a reversible, high temperature redox cycle including an endothermic oxygen-releasing reaction and exothermic oxygen-incorporation reaction. Concentrated solar radiation heats the redox-active oxide particles under partial vacuum to drive the reduction extent deeper for increased energy density at a fixed temperature, thereby increasing storage capacity while limiting the required on sun temperature. Direct counter-current contact of the reduced particles with compressed air from the Brayton compressor releases stored chemical and sensible energy, heating the air to 1,200°C at the turbine inlet while cooling and reoxidizing the particles. The cool oxidized particles recirculate through the solar receiver subsystem for another cycle of heating and reduction (oxygen release). We applied the techno-economic model to 1) size components, 2) examine intraday operation with varying solar insolation, 3) estimate annual performance characteristics over a simulated year, 4) estimate the levelized cost of electricity (LCOE), and 5) perform sensitivity analyses to evaluate factors that affect performance and cost. Simulations use hourly solar radiation data from Barstow, California to assess the performance of a 111.7 MW e system with solar multiples (SMs) varying from 1.2 to 2.4 and storage capacities of 6–14 h. The baseline system with 6 h storage and SM of 1.8 has a capacity factor of 54.2%, an increase from 32.3% capacity factor with no storage, and an average annual energy efficiency of 20.6%. Calculations show a system with an output of 710 GWh e net electricity per year, 12 h storage, and SM of 2.4 to have an installed cost of $329 million, and an LCOE of 5.98 ¢/kWh e . This value meets the U.S. Department of Energy’s SunShot 2020 target of 6.0 ¢/kWh e ( U. S Department of Energy, 2012 ), but falls just shy of the 5.0 ¢/kWh e 2030 CSP target for dispatchable electricity ( U. S Department of Energy, 2017 ). The cost and performance results are minimally sensitive to most design parameters. However, a one-point change in the weighted annual cost of capital from 8 to 7% (better understood as a 12.5% change) translates directly to an 11% decrease (0.66 ¢/kWhe) in the LCOE.

Gorman, Brandon T.↗

Coupling thermal energy storage with a thermally anisotropic building envelope for building demand-side management across various US climate conditions

Here, the thermally anisotropic building envelope (TABE) is a novel active building envelope that enhances energy efficiency and thermal comfort in buildings by transferring heat and cold between building envelopes and hydronic loops. When coupled with thermal energy storage (TES) units, the TABE + TES enables the storage of both heat and cold energy captured by the TABE roof or exterior walls. This stored energy can be later released by the TABE floor for indoor heating and cooling, benefiting both the grid and the end user. This paper evaluates the merits of TABE + TES for building demand-side management across various US climate conditions, focusing on peak load shaving, annual energy savings, and cost savings under time-of-use (TOU) electric rate schedules. Simulations were conducted by integrating time-of-day–informed, rule-based control strategies in MATLAB, TABE components and TES units in COMSOL Multiphysics, and whole-building energy analysis in EnergyPlus. A case study using the US Department of Energy’s prototype single-family detached house model in Birmingham, Alabama; Los Angeles, California; Oak Ridge, Tennessee; and Denver, Colorado, showed that the TABE + TES system achieved (1) 70 % peak load shaving in Los Angeles and Denver and 20 % in Birmingham and Oak Ridge; (2) significant peak electricity savings of 351–497 kWh, reducing peak energy consumption by 38 %–78 %; and (3) annual heating cost savings of 0.79 $\$$/m2–1.17 $\$$/m 2 and cooling cost savings of 0.60 $\$$/m 2 –1.17 $\$$/m 2 using a normal utility rate or low-TOU rate. The benefits of employing the TABE + TES system are even more significant under high TOU rates.

25 ENERGY STORAGE↗

FIPD: The SFR metallic fuels irradiation & physics database

The DOE Advanced Reactor Technology (ART) program has supported efforts to recover and preserve metallic fuel data generated throughout the US sodium-cooled fast reactor (SFR) program. Those efforts have been focused on establishing databases of the experimental data that were mainly generated during the Integral Fast Reactor (IFR) program including data generated at Experimental Breeder Reactor-II (EBR-II), Fast Flux Test Facility (FFTF), and Transient Reactor Test Facility (TREAT) reactors, as well as out of pile data. The data is essential for future licensing activities of metallic fuel based advanced fast reactors. This paper describes the development of the SFR Metallic Fuels Irradiation & Physics Database (FIPD) and covers the scientific knowledge available in the database. Furthermore, the architecture of the FIPD is described by showing the available reactor operation data, fabrication, and post-irradiation examination (PIE) data, and other documents. The applications of the fuel database are also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗