Search NASA⌕ Search

SEARCH · Search NASA

Results for “Adhesion Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Applying uniform adhesive coatings

Removable overlay keeps thickness variations small, saving material and application time. In comparative tests against roller, brush, and spray application, thickness variations in the conventional techniques were at least three times greater.

Wang, D. S.↗

Repeatability of mixed-mode adhesive debonding

The repeatability of debond growth rates in adhesively bonded subjected to constant-amplitude cyclic loading was studied. Debond growth rates were compared from two sets of cracked-lap-shear specimens that were fabricated by two different manufacturers and tested in different laboratories. The fabrication method and testing procedures were identical for both sets of specimens. The specimens consisted of aluminum adherends bonded with FM-73 adhesive. Critical values of strain-energy-release rate were also determined from specimens that were monotonically loaded to failure. The test results showed that the debond growth rates for the two sets of specimens were within a scatter band which is similar to that observed in fatigue crack growth in metals. Cyclic debonding occurred at strain-energy-release rates that were more than an order of magnitude less than the critical strain-energy-release rate in static tests.

Everett, R. A., Jr.↗

Repeatability of mixed-mode adhesive debonding

The repeatability of debond growth rates in adhesively bonded subjected to constant-amplitude cyclic loading was studied. Debond growth rates were compared from two sets of cracked-lap-shear specimens that were fabricated by two different manufacturers and tested in different laboratories. The fabrication method and testing procedures were identical or both sets of specimens. The specimens consisted of aluminum adherends bonded with FM-73 adhesive. Critical values of strain-energy-release rate were also determined from specimens that were monotonically loaded to failure. The test results showed that the debond growth rates for the two sets of specimens were within a scatter band which is similar to that observed in fatigue crack growth in metals. Cyclic debonding occurred at strain-energy-release rates that were more than an order of magnitude less than the critical strain-energy-release rate in static tests.

Everett, R. A., Jr.↗

Thermal Systems and Materials Testing

During my internship, I was involved in Boeing Thermal System/M&P, which handles maintenance and repairs of shuttle tiles, blankets, gap fillers, etc. One project I took part in was the revision of TPS-227, a repair process to tiles that entailed drilling out tile damage and using a cylindrical insert to fill the hole. The previous specification used minimal adhesive for application and when the adhesive cured, there would be several voids in the adhered material, causing an unsatisfactory bond. The testing compared several new methods and I analyzed the number of voids produced by each method to determine which one was most effective at eliminating void space. We revised the original process to apply a light adhesive coat to the top 25% of the borehole and a heavy coat to 100% of the insert. I was also responsible for maintaining the subnominal bond database, which records all unsatisfactory SIP (Strain Isolator Pad) bonds. I then archived each SIP physically for future referral data and statistics. In addition, I performed post-flight tile inspections for damages and wrote dispositions to have these tiles repaired. This also included writing a post-flight damage report for a section of Atlantis and creating summarized repair process guidelines for orbiter technicians.

Aguirre, Nathan↗

Vacuum Ultraviolet Radiation and Atomic Oxygen Durability Evaluation of HST Bi-Stem Thermal Shield Materials

Bellows-type thermal shields were used on the bi-stems of replacement solar arrays installed on the Hubble Space Telescope (HST) during the first HST servicing mission (SMI) in December 1993. These thermal shields helped reduce the problem of thermal gradient- induced jitter observed with the original HST solar arrays during orbital thermal cycling and have been in use on HST for eight years. This paper describes ground testing of the candidate solar array bi-stem thermal shield materials including backside aluminized Teflon(R)FEP (fluorinated ethylene propylene) with and without atomic oxygen (AO) and ultraviolet radiation protective surface coatings for durability to AO and combined AO and vacuum ultraviolet (VOV) radiation. NASA Glenn Research Center (GRC) conducted VUV and AO exposures of samples of candidate thermal shield materials at HST operational temperatures and pre- and post-exposure analyses as part of an overall program coordinated by NASA Goddard Space Flight Center (GSFC) to determine the on-orbit durability of these materials. Coating adhesion problems were observed for samples having the AO- and combined AO/UV-protective coatings. Coating lamination occurred with rapid thermal cycling testing which simulated orbital thermal cycling. This lack of adhesion caused production of coating flakes from the material that would have posed a serious risk to HST optics if the coated materials were used for the bi-stem thermal shields. No serious degradation was observed for the uncoated aluminized Teflon(R) as evaluated by optical microscopy, although atomic force microscopy (AFM) microhardness testing revealed that an embrittled surface layer formed on the uncoated Teflon(R) surface due to vacuum ultraviolet radiation exposure. This embrittled layer was not completely removed by AO erosion, No cracks or particle flakes were produced for the embrittled uncoated material upon exposure to VUV and AO at operational temperatures to an equivalent exposure of approximately five years in the HST environment. Uncoated aluminized FEP Teflon(R) was determined to be the most appropriate thermal shield material and was used on the bi-stems of replacement solar arrays installed on HST during SMI in December 1993. The SMI -installed solar arrays air scheduled to be replaced during MST's fourth servicing mission (SM3B) in early 2002.

Dever, Joyce↗

Studies of fiber-matrix adhesion on compression strength

A study was initiated on the effect of the matrix polymer and the fiber matrix bond strength of carbon fiber polymer matrix composites. The work includes tests with micro-composites, single ply composites, laminates, and multi-axial loaded cylinders. The results obtained thus far indicate that weak fiber-matrix adhesion dramatically reduces 0 degree compression strength. Evidence is also presented that the flaws in the carbon fiber that govern compression strength differ from those that determine fiber tensile strength. Examination of post-failure damage in the single ply tests indicates kink banding at the crack tip.

Bascom, Willard D.↗

Summary of materials and hardware performance on LDEF

A wide variety of materials and experiment support hardware were flown on the Long Duration Exposure Facility (LDEF). Postflight testing has determined the effects of the almost 6 years of low-earth orbit (LEO) exposure on this hardware. An overview of the results are presented. Hardware discussed includes adhesives, fasteners, lubricants, data storage systems, solar cells, seals, and the LDEF structure. Lessons learned from the testing and analysis of LDEF hardware is also presented.

Dursch, Harry↗

Investigation of welded interconnection of large area wraparound contacted silicon solar cells

An investigation was conducted to evaluate the welding and temperature cycle testing of large area 5.9 x 5.9 wraparound silicon solar cells utilizing printed circuit substrates with SSC-155 interconnect copper metals and the LMSC Infrared Controlled weld station. An initial group of 5 welded modules containing Phase 2 developmental 5.9 x 5.9 cm cells were subjected to cyclical temperatures of + or 80 C at a rate of 120 cycles per day. Anomalies were noted in the adhesion of the cell contact metallization; therefore, 5 additional modules were fabricated and tested using available Phase I cells with demonstrated contact integrity. Cycling of the later module type through 12,000 cycles indicated the viability of this type of lightweight flexible array concept. This project demonstrated acceptable use of an alternate interconnect copper in combination with large area wraparound cells and emphasized the necessity to implement weld pull as opposed to solder pull procedures at the cell vendors for cells that will be interconnected by welding.

Lott, D. R.↗

Use of thin plastic films at cryogenic temperatures

Commercially available plastic film materials that remain flexible at cryogenic temperatures and resist failures caused by folds and wrinkles created during expulsion were investigated for use in expulsion bladders for liquefied gases. Compatible adhesive systems, fabrication techniques, and results of impact and dynamic loading tests are summarized.

Lark, R. F.↗

Sealing microcircuits with adhesives

Report describes study of adhesive-sealed packages for hybrid microcircuits. Ten commercially available adhesives were used to seal metal and ceramic packages and were tested for moisture resistance at high humidity.

Licari, J. J.↗

Graphite/epoxy-tape test specimens

Constructed specimens for tranverse tensile testing of unidirectional graphite/epoxy tape is tested more accurately than earlier samples. Specimens are made using unsupported adhesive and commercially-available (e.g., Nomex, or equivalent) honeycomb core. Flexible adhesive and dimensionally stable core eliminate uneven thermal expansion. Tensile strength of tape at various temperatures becomes direct function of applied mechanical stress.

Cupp, J. L.↗

Composites for Advanced Space Transportation Systems (CASTS)

A summary is given of the in-house and contract work accomplished under the CASTS Project. In July 1975 the CASTS Project was initiated to develop graphite fiber/polyimide matrix (GR/PI) composite structures with 589K (600 F) operational capability for application to aerospace vehicles. Major tasks include: (1) screening composites and adhesives, (2) developing fabrication procedures and specifications, (3) developing design allowables test methods and data, and (4) design and test of structural elements and construction of an aft body flap for the Space Shuttle Orbiter Vehicle which will be ground tested. Portions of the information are from ongoing research and must be considered preliminary. The CASTS Project is scheduled to be completed in September 1983.

Davis, J. G., Jr.↗

STPI/LARC: A 200 deg C polyimide adhesive

A copolyimide, STPI/LARC, was prepared from the reaction of 3,3'4'benzophenonetetracarboxylic dianhydride (BTDA), equimolar quantities of m-phenylenediamine and 4,4'-oxydianiline, and a small amount of phthalic anhydride to control the molecular weight. The processability and adhesive properties of STPI/LARC were compared to those of a commercially available form of LARC-TPI. LARC-TPI, a thermoplastic polyimide, from the reaction of BTDA and 3,3'-diaminobenzophenone, had previously shown promise as a high temperature structural adhesive. Lap shear specimens were fabricated using adhesive tape prepared from each of the two polymers. Lap shear tests were performed at room temperature, 177 C, and 204 C before and after exposure to a 72-hour water-boil and to aging at 204 C.

Progar, D. J.↗

Viscoelastic modelling of epoxy-resins for adhesive and composite applications

Nonlinear viscoelastic and thermoelastic characterization procedures were applied to a rubber toughened adhesive that is commercially available as FM-300. Long time (accelerated testing) predictions on the basis of stress-time-superposition and time-temperature-superposition were compared with actual long term data. Good verification was obtained.

Hiel, C.↗

Development and evaluation of superconducting circuit elements

An approach to the application of high Tc ceramic superconductors to practical circuit elements was developed and demonstrated. This method, known as the rigid-conductor process (RCP), involves the combination of a pre-formed, sintered, and tested superconductor material with an appropriate, rigid substrate via an epoxy adhesive which also serves to encapsulate the element from the ambient environment. Emphasis was on the practical means to achieve functional, reliable, and reproducible components. Although all of the work described in this report involved a YBa2Cu3Osub(7-x) high Tc superconductor material, the techniques developed and conclusions reached are equally applicable to other high Tc materials.

Haertling, Gene H.↗

Ceramic superconducting components

An approach to the application of high-Tc ceramic superconductors to practical circuit elements was developed and demonstrated. This method, known as the rigid conductor process (RCP), involves the mounting of a preformed, sintered, and tested superconductor material onto an appropriate, rigid substrate with an epoxy adhesive which also serves to encapsulate the element from the ambient environment. Circuit elements such as straight conductors, coils and connectors were fabricated from YBa2Cu3O(7-x) superconducting material. Performance results are included for a low-noise low-thermal-conductivity superconducting grounding link for NASA.

Haertling, G. H.↗

A thermoplastic copolyimide

A copolyimide, STPI/LARC, was prepared from the reaction of 3,3'4,4'-benzophenonetetracarboxylic dianhydride (BTDA), equimolar quantities of m-phenylenediamine and 4,4'-oxydianiline, and a small amount of phthalic anhydride to control the molecular weight. The processability and adhesive properties of STPI/LARC were compared to those of a commercially available form of LARC-TPI. LARC-TPI, a thermoplastic polyimide, from the reaction of BTDA and 3,3'-diaminobenzophenone, had previously shown promise as a high temperature structural adhesive. Lap shear specimens were fabricated using adhesive tape prepared from each of the two polymers. Lap shear tests were performed at room temperature, 177 C, and 204 C before and after exposure to a 72-hour water-boil and to aging at 204 C.

Progar, D. J.↗

Investigation Leads to Improved Understanding of Space Shuttle RSRM Internal Insulation Joints

The Space Shuttle Reusable Solid Rocket Motor (RSRM) uses an internal insulation J-joint design for the mated insulation interface between two assembled RSRM segments. In this assembled (mated) segment configuration, this J-joint design serves as a thermal barrier to prevent hot gases from affecting the case field joint metal surfaces and O-rings. A pressure sensitive adhesive (PSA) provides some adhesion between the two mated insulation surfaces. In 1995, after extensive testing, a new ODC-free PSA (free of ozone depleting chemicals) was selected for flight on RSRM-55 (STS-78). Post-flight inspection revealed that the J-joint, equipped with the new ODC-free PSA, did not perform well. Hot gas seeped inside the J-joint interface. Although not a flight safety threat, the J-joint hot gas intrusion on RSRM-55 was a mystery to the investigators since the PSA had previously worked well on a full-scale static test. A team was assembled to study the J-joint and PSA further. All J-joint design parameters, measured data, and historical performance data were re-reviewed and evaluated by subscale testing and analysis. Although both the ODC-free and old PSA were weakened by humidity, the ODC-free PSA strength was lower to start with. Another RSRM full-scale static test was conducted in 1998 and intentionally duplicated the gas intrusion. This test, along with many concurring tests, showed that if a J-joint was 1) mated with the new ODC-free PSA, 2) exposed to a history of high humidity (Kennedy Space Center levels), and 3) also a joint which experienced significant but normal joint motion (J-joint deformation resulting from motor pressurization dynamics) then that J-joint would open (allow gas intrusion) during motor operation. When all of the data from the analyses, subscale tests, and full-scale tests were considered together, a theory emerged. Most of the joint motion on the RSRM occurs early in motor operation at which point the J-joints are pulled into tension. If the new PSA has been weakened due to humidity, then the J-joint will partially pull apart (inboard side), and the J-joint surfaces will be charred by exposure to hot gases. After early operation, a J-joint that has been pulled apart will come back together as the J-joint deformation decreases. This J-joint heating event is relatively short and occurs only during the first part of motor operation. Internal instrumentation was developed for another full-scale static test in February 2000. The static test instrumentation did indeed prove this theory to be correct. Post-test inspection revealed very similar charring characteristics as observed on RSRM-55. This experience of the development of a new PSA, its testing, the RSRM-55 flight, followed by the J-joint investigation led to good 'lessons learned' and to an additional fundamental understanding of the RSRM J-joint function.

McWhorter, Bruce B.↗