In situ 3‐D mapping of pore structures and hollow grains of interplanetary dust particles with phase contrast X‐ray nanotomography

Abstract Unlocking the 3‐D structure and properties of intact chondritic porous interplanetary dust particles ( IDP s) in nanoscale detail is challenging, which is also complicated by atmospheric entry heating, but is important for advancing our understanding of the formation and origins of IDP s and planetary bodies as well as dust and ice agglomeration in the outer protoplanetary disk. Here, we show that indigenous pores, pristine grains, and thermal alteration products throughout intact particles can be noninvasively visualized and distinguished morphologically and microstructurally in 3‐D detail down to ~10 nm by exploiting phase contrast X‐ray nanotomography. We have uncovered the surprisingly intricate, submicron, and nanoscale pore structures of a ~10‐μm‐long porous IDP , consisting of two types of voids that are interconnected in 3‐D space. One is morphologically primitive and mostly submicron‐sized intergranular voids that are ubiquitous; the other is morphologically advanced and well‐defined intragranular nanoholes that run through the approximate centers of ~0.3 μm or lower submicron hollow grains. The distinct hollow grains exhibit complex 3‐D morphologies but in 2‐D projections resemble typical organic hollow globules observed by transmission electron microscopy. The particle, with its outer region characterized by rough vesicular structures due to thermal alteration, has turned out to be an inherently fragile and intricately submicron‐ and nanoporous aggregate of the sub‐μm grains or grain clumps that are delicately bound together frequently with little grain‐to‐grain contact in 3‐D space.

Hu, Z. W.↗

Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance

Purpose: A flat-panel detector based mobile isocentric C-arm for cone-beam CT (CBCT) has been developed to allow intraoperative 3D imaging with sub-millimeter spatial resolution and soft-tissue visibility. Image quality and radiation dose were evaluated in spinal surgery, commonly relying on lower-performance image intensifier based mobile C-arms. Scan protocols were developed for task-specific imaging at minimum dose, in-room exposure was evaluated, and integration of the imaging system with a surgical guidance system was demonstrated in preclinical studies of minimally invasive spine surgery. Methods: Radiation dose was assessed as a function of kilovolt (peak) (80-120 kVp) and milliampere second using thoracic and lumbar spine dosimetry phantoms. In-room radiation exposure was measured throughout the operating room for various CBCT scan protocols. Image quality was assessed using tissue-equivalent inserts in chest and abdomen phantoms to evaluate bone and soft-tissue contrast-to-noise ratio as a function of dose, and task-specific protocols (i.e., visualization of bone or soft-tissues) were defined. Results were applied in preclinical studies using a cadaveric torso simulating minimally invasive, transpedicular surgery. Results: Task-specific CBCT protocols identified include: thoracic bone visualization (100 kVp; 60 mAs; 1.8 mGy); lumbar bone visualization (100 kVp; 130 mAs; 3.2 mGy); thoracic soft-tissue visualization (100 kVp; 230 mAs; 4.3 mGy); and lumbar soft-tissue visualization (120 kVp; 460 mAs; 10.6 mGy) - each at (0.3 x 0.3 x 0.9 mm{sup 3}) voxel size. Alternative lower-dose, lower-resolution soft-tissue visualization protocols were identified (100 kVp; 230 mAs; 5.1 mGy) for the lumbar region at (0.3 x 0.3 x 1.5 mm{sup 3}) voxel size. Half-scan orbit of the C-arm (x-ray tube traversing under the table) was dosimetrically advantageous (prepatient attenuation) with a nonuniform dose distribution ({approx}2 x higher at the entrance side than at isocenter, and {approx}3-4 lower at the exit side). The in-room dose (microsievert) per unit scan dose (milligray) ranged from {approx}21 {mu}Sv/mGy on average at tableside to {approx}0.1 {mu}Sv/mGy at 2.0 m distance to isocenter. All protocols involve surgical staff stepping behind a shield wall for each CBCT scan, therefore imparting {approx}zero dose to staff. Protocol implementation in preclinical cadaveric studies demonstrate integration of the C-arm with a navigation system for spine surgery guidance-specifically, minimally invasive vertebroplasty in which the system provided accurate guidance and visualization of needle placement and bone cement distribution. Cumulative dose including multiple intraoperative scans was {approx}11.5 mGy for CBCT-guided thoracic vertebroplasty and {approx}23.2 mGy for lumbar vertebroplasty, with dose to staff at tableside reduced to {approx}1 min of fluoroscopy time ({approx}40-60 {mu}Sv), compared to 5-11 min for the conventional approach. Conclusions: Intraoperative CBCT using a high-performance mobile C-arm prototype demonstrates image quality suitable to guidance of spine surgery, with task-specific protocols providing an important basis for minimizing radiation dose, while maintaining image quality sufficient for surgical guidance. Images demonstrate a significant advance in spatial resolution and soft-tissue visibility, and CBCT guidance offers the potential to reduce fluoroscopy reliance, reducing cumulative dose to patient and staff. Integration with a surgical guidance system demonstrates precise tracking and visualization in up-to-date images (alleviating reliance on preoperative images only), including detection of errors or suboptimal surgical outcomes in the operating room.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing lattice defects in crystalline battery cathode using hard X-ray nanoprobe with data-driven modeling

Lattice defects, e.g., dislocations and grain boundaries, critically impact the properties of crystalline battery cathode materials. A longstanding challenge is to probe the meso–scale heterogeneity and evolution of lattice defects with sensitivity to atomic-scale details. Herein, we tackle this issue with a unique combination of X-ray nanoprobe diffractive imaging and advanced machine learning techniques. The domains with different lattice defect configuration within a single-crystalline LiCoO2 cathode particle are faithfully revealed using our approach. We further visualize the rearrangement of grain boundaries and local crystallinity upon mild thermal annealing. Furthermore, these results pave a direct way to the understanding of crystalline battery materials’ response under external stimuli with high fidelity, which provides valuable empirical guidance to defect-engineering strategies for improving the cathode materials against aggressive battery operation.

36 MATERIALS SCIENCE↗

Developing Novel Performance Measures for Traffic Congestion Management and Operational Planning Based on Connected Vehicle Data

In this study, the authors present their efforts in exploring a new type of traffic data, referred to as internet-connected vehicle (ICV) data, for traffic congestion management and operational planning. Most currently manufactured vehicles contain onboard GPS and cellular modules, and they constantly connect to automobile manufacturers' clouds via cellular networks and upload their status. Some automobile manufacturers have recently redistributed the nonpersonal part of such data, such as geolocation, to third-party organizations for innovative applications. Compared with the traditional vehicle GPS data, the ICV data contain high-resolution GPS waypoints accompanied with the vehicles' abnormal moving events (e.g., hard braking). The ICV data also have huge potential in congestion management and operational planning. They explore to identify and analyze traffic congestion on both freeways and arterials using the ICV data. The ICV data adopted for this research are redistributed by Wejo Data Service, representing 10%-15% of all moving vehicles in the Dallas-Fort Worth (DFW) area in Texas. Through one case study for a freeway segment and one for an arterial segment, new traffic performance metrics based on the characteristics of ICV data have been presented. The highlights of these efforts are as follows: (I) queue length and propagation at freeway bottlenecks can be directly measured based on where and when most internet-connected vehicles slow down and join the queue; (II) an internet-connected vehicle's actual delay time on arterials can be directly measured according to its slow movement percentage, without assuming the nondelay travel speed; and (III) the ICV data set are also combined with the high-resolution traffic signal events to generate a ground-truth time-space diagram (TSD) on arterials - a common visualization of arterial signal performance for transportation planning and operations.

33 ADVANCED PROPULSION SYSTEMS↗

Retrofit Energy Analysis and Central Thermal modeling (REACT) v1.0

REACT is a website designed to simplify the analysis and decision-making process for retrofitting existing central plant heating and cooling systems with advanced heat pump technologies. The tool evaluates the technical and economic viability of replacing traditional boilers with various options including water-to-water or air-to-water heat pumps, which can provide efficient and lower-cost heating and cooling. It allows users to compare current central plant configurations with retrofit scenarios, assessing energy consumption, life-cycle costs, and environmental impact. Retrofitting traditional boiler and chiller systems with water-to-water or air-to-water heat pumps can significantly reduce energy consumption and lower lifecycle costs. The REACT provides: User-Friendly Tools: A user friendly web interface for quick, intuitive analysis accessible to non-experts. Advanced Modeling: A Python-powered engine for detailed parametric studies, optimization, and research applications. Comprehensive Analysis: Lifecycle cost evaluation, energy consumption modeling, and environmental impact assessment. Visual Insights: A variety of plots to visualize system performance and design trade-offs. The engine for the website (REACT) bases on several Python libraries, and the website will be hosted on an ETA server.

Kim, Donghun [Lawrence Berkeley National Laborator↗

Analyzing Multifaceted Scientific Data with Topological Analytics (Final Technical Report)

This final technical report describes the activities undertaken through Department of Energy, Office of Science, Advanced Scientific Computing Research Early Career award DE-SC-0019039, “Analyzing Multifaceted Scientific Data with Topological Analytics." This report summarizes contributions made toward the research of visualization, machine learning, and topological data analysis of complex simulation data.

97 MATHEMATICS AND COMPUTING↗

Advances in Nuclear Radiation Sensing: Enabling 3-D Gamma-Ray Vision

The enormous advances in sensing and data processing technologies in combination with recent developments in nuclear radiation detection and imaging enable unprecedented and “smarter” ways to detect, map, and visualize nuclear radiation. The recently developed concept of three-dimensional (3-D) Scene-data fusion allows us now to “see” nuclear radiation in three dimensions, in real time, and specific to radionuclides. It is based on a multi-sensor instrument that is able to map a local scene and to fuse the scene data with nuclear radiation data in 3-D while the instrument is freely moving through the scene. This new concept is agnostic of the deployment platform and the specific radiation detection or imaging modality. We have demonstrated this 3-D Scene-data fusion concept in a range of configurations in locations, such as the Fukushima Prefecture in Japan or Chernobyl in Ukraine on unmanned and manned aerial and ground-based platforms. It provides new means in the detection, mapping, and visualization of radiological and nuclear materials relevant for the safe and secure operation of nuclear and radiological facilities or in the response to accidental or intentional releases of radioactive materials where a timely, accurate, and effective assessment is critical. In addition, the ability to visualize nuclear radiation in 3-D and in real time provides new means in the communication with public and facilitates to overcome one of the major public concerns of not being able to “see” nuclear radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GazeAppraise v. 0.1

GazeAppraise advances the state of the art of gaze pattern analysis using methods that simultaneously analyze spatial and temporal characteristics of gaze patterns. GazeAppraise enables novel research in visual perception and cognition; for example, using shape features as distinguishing elements to assess individual differences in visual search strategy. Given a set of point-to-point gaze sequences, hereafter referred to as scanpaths, the method constructs multiple descriptive features for each scanpath. Once the scanpath features have been calculated, they are used to form a multidimensional vector representing each scanpath and cluster analysis is performed on the set of vectors from all scanpaths. An additional benefit of this method is the identification of causal or correlated characteristics of the stimuli, subjects, and visual task through statistical analysis of descriptive metadata distributions within and across clusters.

Wilson, Andrew↗

3-D advanced gas-cooled nuclear reactor fuel channel reconstruction using structure-from-motion - 110

During planned, periodic outages, a selection of fuel channels within the UK fleet of Advanced Gas-cooled Reactor (AGR) cores are inspected using specialist tools which record video footage and other sensory data for each channel which undergoes inspection. Current visualization techniques comprise of manually produced montages by inspection engineers of points of interest (i.e. structural defects) and 2-D panoramic images of the fuel channels automatically produced using bespoke image stitching software. Both techniques however provide limited structural information due to the loss of depth data as a result of the image formation process. By recovering the depth information from the footage, a 3D model could be constructed and subsequently, allow for more accurate profiling of specific defects observed during inspection in addition to obtaining the fuel channels structure using existing footage. This work explores the preliminary application of a 3-D visualization technique known as Structure-from-Motion (SfM) which aims to obtain 3-D information by exploiting image correspondences across multiple viewpoints of the same scene in the RVI footage. This paper investigates the difficulties of applying state-of-the-art SfM to RVI footage and we present new techniques to improve feature correspondence searching in repetitive, nondescript environments. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Three-dimensional imaging of grain boundaries via quantitative fluorescence X-ray tomography analysis

Abstract Three-dimensional visualization of material composition within multiple grains and across complex networks of grain boundaries at nanoscales can provide new insight into the structure evolution and emerging functional properties of the material for diverse applications. Here, using nanoscale scanning X-ray fluorescence tomography, coupled with an advanced self-absorption correction algorithm developed in this work, we analyze the three-dimensional gain distributions and compositions in a Ce 0.8 Gd 0.2 O 2-δ -CoFe 2 O 4 mixed ionic-electronic conductor system with high accuracy and statistical significance. Our systematic investigation reveals an additional emergent phase and uncovers highly intriguing composition stability ranges for the multiple material phases within this system. The presented visualization of composition variations across complex interfaces, supported by our quantitative composition analysis, discloses mechanistic pathways of the diverse phase transformations occurring in the material synthesis, providing insights for the optimization of transport properties in the mixed ionic-electronic conductor system.

36 MATERIALS SCIENCE↗

Treatment Outcome Following Transarterial Chemoembolization in Advanced Bone and Soft Tissue Sarcomas

PurposeTransarterial chemoembolization (TACE) is used to treat unresectable bone and soft tissue sarcoma (STS) and as a pre-surgical adjuvant treatment. However, its efficiency for advanced STS is undetermined. This study evaluated TACE’s efficiency in treating advanced STS and prognostic factors for patient survival.Materials and MethodsWe enrolled 39 patients with unresectable STS who underwent TACE as an alternative treatment during 2010–2014, with overall survival (OS) as the primary end point. Cancer pain was evaluated by visual analogue scores (VAS) before and after TACE procedures. Factors that affect survival were evaluated by multivariate analyses (Cox proportional hazard model).ResultsMean OS after TACE was 23.7 ± 2.1 months, with 1-year OS 71.5 %, 2-year OS 45.8 %, and 3-year OS 32.5 %. Lesion number and tumor stage were key predictors of survival. TACE was found to decrease cancer pain VAS and increase relapse interval. Size of polyvinyl alcohol (PVA) particle diameter (P = 0.03) and imaging response (P = 0.044) were also found to affect relapse interval.ConclusionTACE was an effective treatment for advanced STS, with a 32.5 % 3-year OS rate, and led to lower cancer pain VAS and longer relapse intervals than chemoinfusion only. Smaller PVA particles are preferable during the TACE procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Considerations for imaging thick, low contrast, and beam sensitive samples with liquid cell transmission electron microscopy

Transmission electron microscopy of whole cells is hindered by the inherently large thickness and low atomic contrast intrinsic of cellular material. Liquid cell transmission electron microscopy, allows samples to remain in their native hydrated state and may permit visualizing cellular dynamics in-situ. However, imaging biological cells with this approach remains challenging and identifying an optimal imaging regime using empirical data would help foster new advancements in the field. Recent questions about the role of the electron beam inducing morphological changes or damaging cellular structure and function necessitates further investigation of electron beam-cell interactions, but is complicated by variability in imaging techniques used across various studies currently present in literature. The necessity for using low electron fluxes for imaging biological samples requires finding an imaging strategy which produces the strongest contrast and signal to noise ratio for the electron flux used. Here, we experimentally measure and evaluate signal to noise ratios and damage mechanisms between liquid and cryogenic samples for cells using multiple electron imaging modalities all on the same instrument and with equivalent beam parameters to standardize the comparison. We also discuss considerations for optimal electron microscopy imaging conditions for future studies on whole cells within liquid environments.

Moser, Trevor H. (ORCID:0000000193990514)↗

Nanophotonics for Chemical Imaging and Spectroscopy

The manipulation of light and light-matter interactions on the nanoscale is enabled by the unique optical properties of plasmonic metal nanostructures and nanoparticles. Indeed, engineered hybrid molecular-plasmonic nanostructures have enabled single molecule detection and identification via surface-enhanced Raman scattering (SERS). Further, the same effect is at the core of visualizing single molecules with sub-nanometer spatial resolution via tip-enhanced Raman scattering (TERS). More generally, modern applications of plasmon-enhanced spectroscopy and microscopy fueled advances in fields as diverse as quantum and semiconductor materials, heterogeneous catalysis, and the health sciences, to name a few. All these exciting developments and many more are touched in this virtual special issue (VSI) on nanophotonics. From ultra-precise chemical imaging measurements performed in a scanning tunneling microscope chamber to single molecule spectroscopic measurements performed at solid-air and solid-liquid interfaces, this VSI includes contributions from active practitioners that are all striving to better-understand increasingly complex interfaces encountered in the biological, materials, and chemical sciences.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microreactor Optimization Using Simulation And Economics (mouse)

Microreactor Optimization Using Simulation and Economics (MOUSE) is a tool that integrates both nuclear microreactor design and reactor economics to provide comprehensive evaluations and optimizations. This tool enables stakeholders to explore the interplay between technical and economic variables, guiding them towards effective and competitive microreactor solutions. For the reactor core simulations, MOUSE leverages the OpenMC Monte Carlo Particle Transport Code to perform detailed core simulations for various microreactor designs. The included OpenMC models are 2D core designs of a Liquid Metal Thermal Microreactor (LMTR), a Gas-Cooled TRISO-Fueled Microreactor (GCMR), and a Heat Pipe Microreactor. Beyond core design, MOUSE includes simplified calculations for: - Calculating the masses of heat exchangers within the system. - Mechanical power of pumps. - Estimating the area occupied by various buildings within the nuclear plant. For the economic analysis, MOUSE provides detailed bottom-up cost estimates, encompassing a wide range of costs including preconstruction costs, direct costs, indirect costs, training costs, financial costs, operation & maintenance (O&M) costs, and fuel costs. These cost estimations are developed using data from the MARVEL project and additional literature sources, enabling the calculation of total capital costs and levelized cost of energy for both first-of-a-kind and nth-of-a-kind microreactors. MOUSE also enables analysis of the cost drivers and competitiveness in the electricity market. MOUSE allows users to modify a wide array of technical and economic parameters to evaluate different scenarios and their impacts. Examples of these parameters include: Fuels, coolants, or reflector materials Enrichment levels Control drum materials and geometry Fuel pin geometry and materials Moderator pin geometry and materials Reactor core and reflector dimensions Packing factor for the TRISO particles Nuclear reactor power and reactor burnup Number of sensors Shielding thickness Reactor vessel and guard vessel dimensions Operational staff requirements Number of emergency shutdowns Levelization period Interest rate Construction duration Since MOUSE is powered by the WATTS toolkit, it supports optimization studies, parametric analyses, and uncertainty calculations/propagation. The optimization techniques enable users to identify optimal design and economic configurations. The parametric analysis tools allow users to explore the sensitivity of various parameters, while uncertainty propagation helps quantify the impact of uncertainties on overall performance and cost. User Interface and Workflow: Currently, MOUSE is a command-line-based tool. Users can input various reactor design or economic parameters, modify the designs, run simulations, and visualize results through comprehensive data visualization and reporting capabilities. The typical workflow involves setting up the reactor model, defining economic parameters, running simulations, and analyzing the results to make informed decisions. By combining advanced design calculations with detailed economic modeling, MOUSE provides a robust framework for optimizing nuclear microreactor technologies, enhancing their competitiveness, and guiding stakeholders towards innovative and cost-effective solutions.

Hanna, Botros [Idaho National Laboratory (INL), Id↗

In operando neutron imaging characterizations of all-solid-state batteries

The surge in electric vehicle demand has propagated the extensive application of lithium-ion batteries (LIBs) in recent years. Gaining significant traction due to their promising high-energy density and elevated safety over traditional LIBs, all-solid-state Li batteries (ASLBs) have nonetheless been faced with hurdles relating to battery performance. These include concerns with interfacial compatibility, structural stability, Li dendrite inhibition, and large-scale manufacturing. To tackle these issues, it is necessary to employ advanced characterization methods to comprehend the intrinsic mechanisms within ASLBs. In this article, we advocate for the use of neutron imaging as a nondestructive approach for the operando visualization of ASLBs. We draw comparisons with other operando visualization strategies, underline the benefits of neutron imaging, and discuss its potential applicability in the scrutiny of all-solid-state Li metal batteries and all-solid-state Li-sulfur batteries. Neutron imaging provides valuable insights into the dynamics of Li concentration, reaction mechanisms, and transport constraints in ASLBs. These insights are pivotal in contributing to the evolution of high-performance all-solid-state batteries.

25 ENERGY STORAGE↗

Synchronized Phasor Data for Analyzing Wind Power Plant Dynamic Behavior and Model Validation

The U.S. power industry is undertaking several initiatives that will improve the operations of the power grid. One of those is the implementation of 'wide area measurements' using phasor measurement units (PMUs) to dynamically monitor the operations and the status of the network and provide advanced situational awareness and stability assessment. This project seeks to obtain PMU data from wind power plants and grid reference points and develop software tools to analyze and visualize synchrophasor data for the purpose of better understanding wind power plant dynamic behaviors under normal and contingency conditions.

17 WIND ENERGY↗

Predicted Radiation Output from Several Kilograms of Plutonium Oxide

Neutron and gamma signatures from 3.44 kg of plutonium oxide were predicted with MCNP6 in anticipation of a passive diagnostic measurement campaign. Calculated radiation fields are visualized through use of “FMESH” type tallies. This work is effectively an extension of previous efforts and application of MISC for the photon source term is the main advancement. Large sources of modeling uncertainty include physical can dimensions and thus internal volume and density estimates. Material age is unknown and will also affect the passive gamma signature. The measurement campaign will provide information for model refinement and subsequent simulations. The authors have requested passive data collection on the pair of cans with the largest and smallest mass and such data will be valuable for benchmarking purposes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗