Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM FOCUSING MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Re-Analysis of DARHT Axis 2 S4 Magnet Sweep Measurements

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Understanding fundamental properties of the electron beams is essential to optimizing spot size and dose for radiography. This work describes distribution measurements of a single-kicked electron beam (16.5MeV, 1.7kA, 60ns) at a location downstream at imaging station C on DARHT Axis 2. The beam at station C is focused by the S4 solenoid located upstream. The beam distribution is measured by imaging optical transition radiation (OTR) from electrons striking a 51-µm thick titanium foil. This data and analysis were originally published by Ekdahl. The results here are a re-analysis of the asymmetric halo emittance contribution as compared to the emittance resulting from the FWHM of the distribution. This is accomplished using xtr2 fits to the data which include non-linear magnetic field effects in S4. Also examined are the calculated S4 spherical aberration contributions to the emittance using xtr.

43 PARTICLE ACCELERATORS↗

Design of the EIC hadron storage ring stripline injection kicker with a novel impedance tuning capability

The Electron-Ion Collider (EIC), to be built at Brookhaven National Laboratory, will be a high luminosity (~10 34 cm –2 s –1 ) nuclear science facility. To facilitate EIC experiments, the existing yellow ring of the Relativistic Heavy Ion Collider (RHIC) will be reconfigured to serve as the Hadron Storage Ring (HSR). Designing a stripline injection kicker for the HSR beams, with high magnetic rigidity (~ 82 Tm), poses some technical challenges due to the required large pulsed voltage with long flattop duration, very fast rise time, expected shorter bunch spacing, and potential heating due to higher peak current. In addition, minimizing impedance mismatch in the transition region between the feedthrough and the stripline electrode is challenging. This paper focuses on the mechanical design and optimization of the HSR injection kicker, highlighting a novel impedance tuning capability achieved through an innovative kicker aperture adjustment mechanism. We comprehensively cover the design, including impedance optimization (both beam coupling and characteristic), beam-induced heating, and thermal analysis, and investigation of the maximum electric field due to high voltage signal excitation to ensure safe and reliable operation.

43 PARTICLE ACCELERATORS↗

Parallel high-frequency magnetic sensing with an array of flux transformers and multi-channel optically pumped magnetometer for hand MRI application

Here, we investigate an approach for parallel high-frequency magnetic sensing based on a multi-channel radio frequency (RF) optically pumped magnetometer (OPM) coupled to multiple flux transformers (FTs) with a focus on hand magnetic resonance imaging (MRI) application at ultra-low field (ULF). Multiple RF OPM sensing channels are realized by using a single large-area alkali-metal vapor cell and two laser beams for pumping and probing, shared for all the channels. This design leads to significant cost reduction when multi-channel sensing is desirable, as in the case of ULF MRI. The FT, composed of two connected coils, serves as a transmitter of a target magnetic field to the OPM, while decoupling the OPM from untargeted magnetic fields in the sensing area that can limit the OPM performance. For hand MRI application, theoretical and numerical analysis is performed to determine an optimal geometry for the FT array that could improve signal-to-noise ratio (SNR) and sufficiently reduce crosstalk between FTs. We estimate that the optimized multi-channel FT-OPM sensor can achieve a magnetic field sensitivity of the order of 1 fT / Hz 1 / 2 above 100 kHz, which would be sufficient for 1 mm resolution MRI. In general, the multi-channel capability enables simultaneous magnetic measurements, thus reducing the sensing time and improving the SNR, and we anticipate many applications of the multi-channel FT-OPM sensor beyond the targeted here hand MRI: anatomical parallel ULF MRI of the human brain and other parts of the body, airport security screening, magnetic material imaging, and many others.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of MQXF: The Nb 3 Sn low-β quadrupole for the HiLumi LHC

The High Luminosity (HiLumi) Large Hadron Collider (LHC) project has, as the main objective, to increase the LHC peak luminosity by a factor five and the integrated luminosity by a factor ten. This goal will be achieved mainly with a new interaction region layout, which will allow a stronger focusing of the colliding beams. The target will be to reduce the beam size in the interaction points by a factor of two, which requires doubling the aperture of the low-β (or inner triplet) quadrupole magnets. The use of Nb3Sn superconducting material and, as a result, the possibility of operating at magnetic field levels in the windings higher than 11 T will limit the increase in length of these quadrupoles, called MQXF, to acceptable levels. After the initial design phase, where the key parameters were chosen and the magnet's conceptual design finalized, the MQXF project, a joint effort between the U.S. LHC Accelerator Research Program and the Conseil Europeen pour la Recherche Nucleaire (CERN), has now entered the construction and test phase of the short models. Concurrently, the preparation for the development of the full-length prototypes has been initiated. Lastly, this paper will provide an overview of the project status, describing and reporting on the performance of the superconducting material, the lessons learnt during the fabrication of superconducting coils and support structure, and the fine tuning of the magnet design in view of the start of the prototyping phase.

43 PARTICLE ACCELERATORS↗

A Novel Non-Parametric Density Estimation Approach to Measuring Muon Ionization Cooling and Reverse Emittance Exchange in the MICE Experiment

The Muon Ionization Cooling Experiment (MICE) located at Rutherford Ap- pleton Laboratory in the U.K. has demonstrated muon ionization beam cooling for the rst time. A beam of muons in MICE is produced from high-energy proton beam collision with a xed target, generating pions which in turn decay into muons. Pion-decay muons, thus, are tertiary particles and, as a result, occupy a large vol- ume in position{momentum phase space. To t the muon beam into smaller and more cost-eective accelerating devices, muon beam phase{space volume needs to be reduced (beam cooling). Ionization beam cooling, which before MICE has never been demonstrated experimentally for muons, is the only technique fast enough to be used for muons within their short lifetime. Ionization cooling occurs when muons traverse an absorbing material and lose momentum through ionization energy loss. The cooling eect in MICE is measured using two scintillating-ber tracking detec- tors. These trackers, one upstream and one downstream of the absorber, reconstruct and measure the position and momentum coordinates of each muon. Given the pre- cision MICE needed to demonstrate beam cooling, it is necessary to develop analysis tools that can account for any eects that may lead to inaccurate measurement of cooling, such as non{linear eects in beam optics. Non{parametric density estima- tion techniques, such as kernel density estimation (KDE), provide a basis for creating analysis tools that are robust against these eects, directly calculating the muon beam phase-space density and volume for demonstrating beam cooling. This thesis focuses on the application of KDE to the measurement of beam cooling in MICE. The KDE technique is validated using known distributions and is applied to sim- ulated and experimental MICE data corresponding to the various magnet, optics, and absorber congurations. Using the KDE technique, muon beam cooling in the four{dimensional transverse phase space, as well as reverse emittance exchange using MICE data have been demonstrated.

43 PARTICLE ACCELERATORS↗

Effect of Field Errors in Muon Collider IR Magnets on Beam Dynamics

In order to achieve peak luminosity of a Muon Collider (MC) in the 10{sup 35} cm{sup -2}s{sup -1} range very small values of beta-function at the interaction point (IP) are necessary ({beta}* {le} 1 cm) while the distance from IP to the first quadrupole can not be made shorter than {approx}6 m as dictated by the necessity of detector protection from backgrounds. In the result the beta-function at the final focus quadrupoles can reach 100 km making beam dynamics very sensitive to all kind of errors. In the present report we consider the effects on momentum acceptance and dynamic aperture of multipole field errors in the body of IR dipoles as well as of fringe-fields in both dipoles and quadrupoles in the ase of 1.5 TeV (c.o.m.) MC. Analysis shows these effects to be strong but correctable with dedicated multipole correctors.

43 PARTICLE ACCELERATORS↗

Low field magnetoresistance of gadolinium nanowire

We report low field (μ{sub 0}H < 0.2 T) magnetoresistance (MR) studies on a single Gd nanowire patterned from a nano-structured film (average grain size ∼ 35 nm) by focused ion beam. For comparison, we did similar MR measurements on a polycrystalline sample with large crystallographic grains (∼4 μm). It is observed that in the low field region where the MR is due to motion of magnetic domains, the MR in the large grained sample shows a close relation to the characteristic temperature dependent magnetocrystalline anisotropy including a sharp rise in MR at the spin reorientation transition at 235 K. In stark contrast, in the nanowire, the MR shows complete suppression of the above behaviours and it shows predominance of the grain boundary and spin disorder controlling the domain response.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multi-channel Doppler backscattering measurements in the C-2 field reversed configuration

A versatile heterodyne Doppler Backscattering (DBS) system is used to measure density fluctuation levels (in the wavenumber range kρ{sub s} ≤ 50), and the toroidal E × B flow velocity in the C-2 Field-Reversed Configuration (FRC). Six tunable frequencies in three waveguide bands (26 GHz ≤ f ≤ 90 GHz) are launched using monostatic beam optics, via a quasi-optical beam combiner/polarizer and an adjustable parabolic focusing mirror (inside the vacuum enclosure) achieving Gaussian beam spot sizes of 3–5.5 cm at the X/O-mode cutoff. The DBS system covers plasma densities of 0.8 × 10{sup 13} ≤ n{sub e} ≤ 1 × 10{sup 14} cm{sup −3}, and provides access to the FRC core (up to the field null) and across the FRC separatrix into the scrape-off layer plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental validation of an 8 element EMAT phased array probe for longitudinal wave generation

Sodium cooled Fast Reactors (SFR) use liquid sodium as a coolant. Liquid sodium being opaque, optical techniques cannot be applied to reactor vessel inspection. This makes it necessary to develop alternative ways of assessing the state of the structures immersed in the medium. Ultrasonic pressure waves are well suited for inspection tasks in this environment, especially using pulsed electromagnetic acoustic transducers (EMAT) that generate the ultrasound directly in the liquid sodium. The work carried out at CEA LIST is aimed at developing phased array EMAT probes conditioned for reactor use. The present work focuses on the experimental validation of a newly manufactured 8 element probe which was designed for beam forming imaging in a liquid sodium environment. A parametric study is carried out to determine the optimal setup of the magnetic assembly used in this probe. First laboratory tests on an aluminium block show that the probe has the required beam steering capabilities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Laser Network US Experiments at the University of Texas at Austin

Under Subcontract B638654, The University of Texas at Austin (UT Austin) Center for High Energy Density Science supported three Laser Network US experiments and conducted upgrade planning for the Texas Petawatt Laser Facility. For the experiment “Investigation of the physics of MeV X-ray and particle generation using Compound Parabolic Concentrators” led by Dr. Andrew Mackinnon of Lawrence Livermore National Laboratory, UT Austin provided postdoctoral associate support in the person of Dr. Ganesh Tiwari. For the experiments “Megatesla magnetic fields and enhanced gamma-ray beam generation” led by Hans Rinderknecht of LLE, University of Rochester (experiment) and Alexey Arefiev of UC San Diego (theory) and “High resolution imaging of resonately accelerated electrons under tight focusing” led by Deepak Kumar of ELI-Beamlines, Czech Republic, UT Austin provided the Texas Petawatt Laser staff and a prorated share of the materials and supplies approximately equal to the average of those required for one 5-week experimental campaign. Summaries of these three experiments are provided in this report. Two staff members were hired—Dr. Sandra Bruce at 40% and Dr. Erhard Gaul at 50% time—to support Texas Petawatt Laser maintenance and operations and to plan for the Texas Relativistic Intensity Ultrafast Multi-beam Plasma Facility (TRIUMPF).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Variable-focus magnetostatic lens

Variable-focus solenoidal lenses for charged particle beams with integrated emittance filtering are disclosed. The emittance may be controlled via selection of collimating irises. The focal length may be changed by altering the spacing between two permanent ring magnets.

Lewellen, John↗

Determination of the characteristic magnetic pre-sheath length at divertor surfaces using micro-engineered targets on DiMES at DIII-D

The magnetic pre-sheath (MPS) width, L MPS , is a critical parameter to define the sheath potential, which controls the ion trajectory of low-Z species (D, T, He, and C), as well as the prompt re-deposition of high-Z species. In this work, to determine L MPS , we fabricated micro-trenches (30×30×4 µm) via focused ion beam (FIB) milling on a silicon surface and exposed them to L-mode deuterium plasmas in DIII-D via the Divertor Material Evaluation System (DiMES) removable sample exposure probe. The areal distribution of impurity depositions, mainly consisting of carbon, was measured by energy-dispersive X-ray spectroscopy (EDS) to reveal the deuterium ion shadowing effect on the trench floors. The carbon deposition profiles showed that the erosion was maximized for the azimuthal direction of φ = -40° (referenced to the toroidal magnetic field direction) as well as the polar angle of θ = 80°. A Monte Carlo equation-of-motion model, based on a collisionless MPS, was used to calculate the azimuthal and polar deuterium ion angle distributions (IADs) for a range of L MPS = k × ρ i , where ρ i is the ion gyro radius and k = 0.5-4. Then, gross erosion profiles were calculated by a Monte Carlo micro-patterning and roughness (MPR) code for ion sputtering using as input the calculated azimuthal and polar IADs for each value of k . Good agreement with the experimental C deposition profiles was obtained for the case k = 2.5-3.5. This result is consistent with a previous kinetic modeling prediction of k ~ 3, as well as previous analytical investigations that predicted the L MPS to be several ion gyro radii. A validation of theoretical sheath models supports its applicability to ITER and pilot plant divertors to successfully predict plasma-materials interactions.

Erosion↗

Design of a tapered final focusing magnet for eRHIC

Presently the electron-ion collider eRHIC is underdesign, which aims to provide a facility with a peak luminosity of 10 34 cm –2 sec –1 . Particularly challenging in terms of magnet design are the IR magnets due to the close proximity of the electron and hadron beams. This paper outlines the design for the so-called Q1 rear side magnet, which is a double aperture quadrupole magnet 7.2 m from the interaction region. Due to space restrictions both magnets are housed in the same iron yoke. The aperture of the hadron quadrupole is relatively small, but requires high gradients. While the required gradient for the electron quadrupole is relatively small, the aperture of this magnet needs to accommodate the beam and allow the synchrotron radiation fan to pass through. To accomplish this both quadrupole magnets have a tapered aperture. Furthermore to keep the gradients constant along the length of the magnets a special winding pattern has been identified, which is described in this paper.

43 PARTICLE ACCELERATORS↗

EXTREME PARTICLE ACCELERATION IN MAGNETIC RECONNECTION LAYERS: APPLICATION TO THE GAMMA-RAY FLARES IN THE CRAB NEBULA

The gamma-ray space telescopes AGILE and Fermi detected short and bright synchrotron gamma-ray flares at photon energies above 100 MeV in the Crab Nebula. This discovery suggests that electron-positron pairs in the nebula are accelerated to PeV energies in a milligauss magnetic field, which is difficult to explain with classical models of particle acceleration and pulsar wind nebulae. We investigate whether particle acceleration in a magnetic reconnection layer can account for the puzzling properties of the flares. We numerically integrate relativistic test-particle orbits in the vicinity of the layer, including the radiation reaction force, and using analytical expressions for the large-scale electromagnetic fields. As they get accelerated by the reconnection electric field, the particles are focused deep inside the current layer where the magnetic field is small. The electrons suffer less from synchrotron losses and are accelerated to extremely high energies. Population studies show that, at the end of the layer, the particle distribution piles up at the maximum energy given by the electric potential drop and is focused into a thin fan beam. Applying this model to the Crab Nebula, we find that the emerging synchrotron emission spectrum peaks above 100 MeV and is close to the spectral shape of a single electron. The flare inverse Compton emission is negligible and no detectable emission is expected at other wavelengths. This mechanism provides a plausible explanation for the gamma-ray flares in the Crab Nebula and could be at work in other astrophysical objects such as relativistic jets in active galactic nuclei.

79 ASTRONOMY AND ASTROPHYSICS↗

Topological materials by molecular beam epitaxy

Topology appears across condensed matter physics to describe a wide array of phenomena which could alter, augment, or fundamentally change the functionality of many technologies. Linking the basic science of topological materials to applications requires producing high-quality thin films. This will enable combining dissimilar materials while utilizing dimensionality, symmetry, and strain to create or control the electronic phase, as well as platforms to fabricate novel devices. Yet, one of the longstanding challenges in the field remains understanding and controlling the basic material properties of epitaxial thin films. Here, we discuss how understanding the fundamental properties of topological materials grown by molecular beam epitaxy (MBE) is key to deepening the knowledge of the basic physics, while developing a new generation of topological devices. A focus will be on the MBE growth of intrinsic materials, creation, and control of superconducting and magnetic topological phases. Addressing these questions in the coming decade will undoubtedly uncover many surprises as new materials are discovered and their growth as high-quality thin films is refined.

2d quantum materials↗

Magnetic System for the CLAS12 Proposal

The conceptual design of a magnetic system for an experiment to measure the transverse spin effects in semi-inclusive Deep Inelastic Scattering (SIDIS) at 11 GeV with a transversely polarized target using the CLAS12 detector at Jefferson Lab is presented. A proposal has been submitted to study spin azimuthal asymmetries in SIDIS using an 11-GeV polarized electron beam from the upgraded CEBAF facility and the CLAS12 detector equipped with a transversely polarized target. The main focus of the experiment will be the measurement of transverse target single and double spin asymmetries in the reaction ep{up_arrow} -> ehX, where e is an electron, p{up_arrow} is transversely polarized proton, h is a meson (e.g., a pion or a kaon) and X is the undetected final state. The details of the conceptual design of the shielding magnetic system and transverse dipole are reported.

43 PARTICLE ACCELERATORS↗

Magnetic properties of magnetite nanoparticles coated with mesoporous silica by sonochemical method

Highlights: Black-Right-Pointing-Pointer MCM-41-coating of magnetite nanoparticles performed under ultrasonic irradiation. Black-Right-Pointing-Pointer Ultrasonic irradiation accelerates the formation of the MCM-41 framework. Black-Right-Pointing-Pointer The hysteretic response to an applied field was investigated applying FORC diagram. Black-Right-Pointing-Pointer The average coercive field of the Fe{sub 3}O{sub 4} nanoparticles increased after coating. -- Abstract: In this paper we present the magnetic properties of mesoporous silica-coated Fe{sub 3}O{sub 4} nanoparticles. The coating of magnetite nanoparticles with mesoporous silica shell was performed under ultrasonic irradiation. The obtained mesoporous silica-coated magnetite nanoparticles were characterized by powder X-ray diffraction, focused ion beam-scanning electron microscopy, nitrogen adsorption-desorption isotherms and vibrating sample magnetometer. The hysteretic behavior was studied using first-order reversal curves diagrams. The X-ray diffraction result indicates that the extreme chemical and physical conditions created by acoustic cavitations have an insignificant effect on crystallographic structural characteristic of magnetite nanoparticles. Changes in the coercivity distributions of the magnetite nanoparticles were observed on the first-order reversal curves diagrams for the samples with coated particles compared with the samples containing uncoated particles of magnetite. The coated particles show an increased most probable coercivity of about 20% compared with the uncoated particles which can be associated with an increased anisotropy due to coating even if the interaction field distribution measured on the diagrams are virtually identical for coated/uncoated samples.

36 MATERIALS SCIENCE↗