Plowing Through the Cost Barrier: Zero Energy K-12 Schools for Less: Preprint

There is a perception that zero energy K–12 schools cost more than conventional schools. Zero energy schools provide a number of unique benefits to school districts, students and staff, and communities. Among other things, a zero energy school requires far less energy to operate than a conventional school and uses on-site renewable energy systems to offset that reduced energy load. The money saved on energy can often be used to enhance educational programs. But does the extra value come at a premium? Research findings indicate that not only can zero energy schools be designed and built on conventional school budgets, they can cost less. In an integrated design and construction process, the cost of zero energy measures can be offset by, for example, downsizing heating, ventilating, and air-conditioning systems, reducing both life cycle and first costs. These findings are based on an examination of 88 zero energy or zero energy ready schools across the United States built during the last 15 years. The data collected on these schools include capital costs and the experiences of owners and design teams. The goal was to understand the perceived cost barrier, given that each building was built with a predetermined budget. The results will help future school stakeholders, program administrators, and design teams counter the perceived cost barriers. Successful strategies for achieving zero energy at no initial cost are presented. The lessons learned from existing zero energy schools can help transform the market such that all new schools can be zero energy.

30 DIRECT ENERGY CONVERSION↗

Development of a hardware-in-the-loop testbed for laboratory performance verification of flexible building equipment in typical commercial buildings

The goals of reducing energy costs, shifting electricity peaks, increasing the use of renewable energy, and enhancing the stability of the electric grid can be met in part by fully exploiting the energy flexibility potential of buildings and building equipment. The development of strategies that exploit these flexibilities could be facilitated by publicly available high-resolution datasets illustrating how control of HVAC systems in commercial buildings can be used in different climate zones to shape the energy use profile of a building for grid needs. This article presents the development and integration of a Hardware-In-the-Loop Flexible load Testbed (HILFT) that integrates physical HVAC systems with a simulated building model and simulated occupants with the goal of generating datasets to verify load flexibility of typical commercial buildings. Compared to simulation-only experiments, the hardware-in-the-loop approach captures the dynamics of the physical systems while also allowing efficient testing of various boundary conditions. The HILFT integration in this article is achieved through the co-simulation among various software environments including LabVIEW, MATLAB, and EnergyPlus. Although theoretically viable, such integration has encountered many real-world challenges, such as: 1) how to design the overall data infrastructure to ensure effective, robust, and efficient integration; 2) how to avoid closed-loop hunting between simulated and emulated variables; 3) how to quantify system response times and minimize system delays; and 4) how to assess the overall integration quality. Lessons-learned using the examples of an AHU-VAV system, an air-source heat pump system, and a water-source heat pump system are presented.

Chen, zhelun↗

Design and performance evaluation of a dual-circuit thermal energy storage module for air conditioners

We present experimental results and a validated numerical model of a dual-circuit phase-change thermal energy storage module for air conditioners. The module incorporates a phase-change material encapsulated in compressed expanded natural graphite foam. We used n-tetradecane as the PCM with a transition temperature (~4.5 °C) suitable for air-conditioning applications. Heat exchange to and from the module is accomplished through two fluid loops operating as a heat source and sink embedded inside multiple slabs of the composite material. This dual-circuit design enables easier integration with air-conditioning equipment and provides enhanced flexibility in system operation as compared to the state-of-the-art thermal storage systems. When integrated with an air-conditioner, this design will enable peak-load shaving and enhances operational efficiency. The thermal storage device was designed for a nominal storage capacity of ~ 3.5 kWh. We evaluated the heat transfer and energy storage performance of this device using standalone heat transfer experiments to estimate key thermal resistances and identify design improvements before integration with an air conditioner. The numerical model of the heat exchanger uses a combination of discretized and lumped parameter approaches to maintain a balance between accuracy and computational expense. Our analyses show that the geometric features and integration of fluid tubes are key contributors to the thermal contact resistance between the fluid and the thermal storage material, and consequently, to the overall performance of the thermal storage module. Our standalone experiments also identified important operating scenarios in which this thermal storage module can be used for air-conditioning in buildings.

25 ENERGY STORAGE↗

A Contextually Supervised Optimization-Based HVAC Load Disaggregation Methodology

This paper presents a novel contextually supervised optimization-based approach for disaggregating heating, ventilation, and air-conditioning (HVAC) loads using smart meter or Supervisory Control and Data Acquisition data. To disaggregate the load into HVAC loads, large and infrequently used loads (LIUL), and base loads, we formulate an optimization problem to minimize a set of five loss terms, consisting of the reconstruction errors of the overall load profile, the ramp rate losses, and three distinct loss functions linked with the HVAC load, base load, and LIUL, respectively. To enhance accuracy, we incorporate two forms of contextual information into the problem formulation. First, we utilize mutual information to estimate HVAC energy consumption. Second, we employ a base load dictionary to constrain HVAC load estimation errors. The obtained HVAC load profiles are fine-tuned by abnormal ramp detection followed by binary hypothesis testing. Here, the proposed method is developed and tested using sub-metered residential and commercial building data. Simulation results show that the proposed method outperforms existing methods across various data resolutions and load aggregation levels, showing excellent transferability and generalizability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Special Issue: Thermal Energy Storage for Buildings

This special issue (SI) of the ASME Journal of Engineering for Sustainable Buildings and Cities (JESBC) features peer-reviewed papers specific to technologies and applications of thermal energy storage (TES) for buildings. TES systems store energy in materials as a heat source or a cold sink and then discharge the stored energy hours or weeks later to enhance thermal comfort or reduce utility bills [1]. As buildings and cities are facing increasing energy consumption and extreme weather events, TES offers a powerful solution to balance supply and demand, reduce operational energy costs, and strengthen energy resilience during power outages.

25 ENERGY STORAGE↗

Geologic Seawater Air Conditioning (GeoSWAC) System: Resource Assessment and Techno-Economic Evaluation in Puerto Rico

Puerto Rico's hot, humid climate drives a high and persistent demand for cooling, straining an aging and fuel-dependent energy grid while increasing peak electricity loads. Much of this challenge stems from inefficient air-conditioning systems operating in buildings without passive cooling design, making cooling both costly and vulnerable to disruption - especially during hurricanes. To address these issues, researchers evaluated a new alternative called Geologic Seawater Air Conditioning (GeoSWAC), which uses inland wells connected to naturally cold, deep seawater. By avoiding long offshore pipelines and energy-intensive refrigeration cycles, GeoSWAC can cut electricity use by 75-90%, reduce environmental impacts, and operate more reliably during power outages. A case study at the University of Puerto Rico's Rio Piedras campus found that GeoSWAC could deliver significantly lower levelized costs of cooling, reduced operational expenses, and improved water conservation compared to the campus's existing chilled-water plant. The system offers key advantages - including access to a constant cold heat sink, low pumping requirements, and enhanced resilience - for coastal regions such as Puerto Rico, the broader Caribbean, and Florida. However, its effectiveness depends heavily on site-specific geological conditions, such as subsurface connectivity and aquifer characteristics, which require detailed investigation. Future research should refine hydrogeological models, conduct performance and economic analyses, and address regulatory and permitting frameworks to support broader adoption of this promising technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

InSight's Reconstructed Aerothermal Environments

The InSight Mars Lander successfully landed on the surface on November 26, 2018. This poster will describe the methodologies and margins used in developing the aerothermal environments for design of the thermal protection systems (TPS), as well as a prediction of as-flown environments based on the best estimated trajectory. The InSight mission spacecraft design approach included the effects of radiant heat flux to the aft body from the wake for the first time on a US Mars Mission, due to overwhelming evidence in ground testing for the European ExoMars mission (2009/2010) [1] and 2010 tests in the Electric Arc Shock Tube (EAST) facility [2]. The radiant energy on an aftbody was also recently confirmed via measurement on the Schiaparelli mission [3]. In addition, the InSight mission expected to enter the Mars atmosphere during the dust storm season, so the heatshield TPS was designed to accommodate the extra recession due to the potential dust impact. This poster will compare the predicted aerothermal environments using the reconstructed best estimated trajectory to the design environments. Design Approach: The InSight spacecraft was planned to be a near-design-to-print copy of the Phoenix spacecraft. The determination of the heatshield TPS requirements was approached as if it was a new design due to the new requirement of flying through a dust storm. The baseline for aftbody was build-to-print, and all analyses focused on ensuring adequate margin. This proved to be a challenge because the Phoenix aftbody was designed to withstand only convective heating and the InSight aftbody was evaluated for both convective and radiative heating. Aerothermal environments were predicted using the Langley Aerothermodynamic Upwind Relaxation Algorithm (LAURA) and the Data Parallel Line Relaxation (DPLR) CFD codes, and the Nonequilibrium Radiative Transport and Spectra Program (NEQAIR) utilizing bounding design trajectories derived from Monte Carlo analyses from the Program to Optimize Simulated Trajectories II (POST2). In all cases, super-catalytic flowfields were assigned to ensure the most conservative heating results. Two trajectories were evaluated: 1) the trajectory with the maximum heat flux was utilized to determine the flowfield characteristics and the viability of the selection of TPS materials; and 2) the trajectory with the maximum heat load was used to determine the required thicknesses of the TPS materials. Evaluation of the MEDLI data [4], along with ground test data [5] led to the determination of whether or not the flow would transition from laminar to turbulent on the heatshield, which also determined the TPS sizing location for the heatshield. Aerothermal margins were added for the convective heating and developed for the radiative heating. TPS material sizing was determined with the Reaction Kinetic Ablation Program (REKAP) and the Fully Implicit Ablation and Thermal Analysis program (FIAT) using a three-branched approach to account for aerothermal, material response, and material properties uncertainties. In addition, the heatshield recession was augmented by an analysis of the effect of entry through a potential dusty atmosphere using a methodology developed in References [6] and [7]. These analyses resulted in an increase to the Phoenix heatshield TPS thickness. Reconstruction Efforts: Once the best estimated trajectory is reconstructed by the team, the LAURA/HARA (High-Temperature Aerothermo-dynamic Radiation model) and DPLR/NEQAIR code pairs will be used to predict the as-flown aerothermal conditions. In these runs, fully-catalytic flowfields will be assigned because it is a more physically accurate description of the chemistry in the flow. Once again, determination of the onset of turbulence on the heatshield will be evaluated. The as-flown aerothermal environments will then be compared to the design environments.

Beck, R. A.↗

Modeling and Analysis of Stirling Power Convertors

Modeling and Analysis of Stirling Power Convertors Luis A. Rodriguez1 Steven M. Geng, Terry V. Reid, Scott D. Wilson NASA Glenn Research Center, Cleveland, OH, 44135, USA NASA Glenn’s Thermal Energy Conversion Branch is supporting the development of the next generation free-piston Stirling power convertors. American Superconductor (AMSC) and Sunpower Inc. are the two firms under contract to develop the Flexure Isotope Stirling Convertor (FISC) and the Sunpower Robust Stirling Convertor (SRSC), respectively. To comprehend and forecast convertor performance, Sage, ANSYS® Maxwell, and ANSYS® Fluent were used to model the Stirling thermodynamic cycle, alternator electromagnetics, and piston and displacer dynamics. I. Introduction Stirling convertors are being developed by NASA as a potential steady source of electrical power for NASA’s future scientific space missions. Currently, NASA Glenn Research Center has two corporations under contract, American Superconductor (AMSC) and Sunpower Inc., for the development of the next generation of free-piston Stirling convertors for dynamic radioisotope power systems. AMSC is developing the Flexure Isotope Stirling Convertor (FISC), which uses flexures to prevent side motion and rubbing of the piston. Similarly, Sunpower Inc, is developing the Sunpower Robust Stirling Convertor (SRSC). The SRSC uses gas bearings to prevent radial contact of the moving piston. As convertor development continues, it is increasingly important to understand and predict the interactions of components in the system, how they respond to one another, and how they perform as a response to changes in operating conditions. A suitable and enlightening way to demonstrate and foresee these interactions is with the use of accurate modeling software. Sage, ANSYS® Maxwell, and ANSYS® Fluent are the current modeling tools used by NASA to analytically determine convertor performance. Sage is a one-dimensional object-oriented commercial software package used for modeling and optimizing Stirling convertors for Dynamic Radioisotope Power Systems (DRPS) and it is one of the most accurate Stirling convertor codes in use by NASA. This code is the successor to GLIMPS (Globally-Implicit Stirling Cycle Simulation) and GLOP (GLIMPS Optimization) software created by Gedeon Associates [1]. Model input parameters are typically material/gas type, component physical dimensions, temperatures, frequency, charge pressure, and number of time/space nodes. Sage is used to model both the FISC’s and SRSC’s Stirling cycle thermodynamics and piston/displacer dynamics. Performance maps were created and analyzed for both power systems to better understand the relationship between the following conditions: cold-end temperature, hot-end temperature, piston/displacer amplitudes, pressure drop, and thermal input power. The synergy between these conditions will help determine parameter sensitivity. ANSYS® Maxwell was used to create a three-dimensional (3-D) axisymmetric model for both FISC and SRSC alternators. The significant physical components included in each model are the magnets, magnet carrier, outer/inner laminations, and the coil. Inputs to the model are piston amplitude, piston frequency, alternator load, coil resistance, tuning capacitance, and specific material properties. The alternator models calculate terminal voltage, current, piston/current phase, voltage/current phase, coil inductance, terminal power and efficiency. The RI2 losses, core (hysteresis and eddy) losses, and magnet/can eddy losses are also a part of the final results. ANSYS® Fluent is used to build 3-D computational fluid dynamic (CFD) models to examine the Stirling cycle thermodynamics for both the FISC and SRSC systems. Three-dimensional Computer Aided Design (CAD) models were used to create the physical components of each convertor. Steady-state simulations were conducted for hardware testing, prediction of environmental losses during testing, and generation of radiation look-up tables. The model inputs to the aforementioned analysis are the material properties and boundary thermal conditions. The steady-state model calculates temperature and heat flow distributions. Transient 3-D calculations were also part of the CFD analysis. In this study a physically reduced version of the FISC is used to obtain a prediction of available engine power. For the gas bearing SRSC, the transient effort is used to obtain a prediction of bearing pad performance and its sensitivity to micro-channel geometric variation. The model inputs to the transient simulations are the piston amplitude, displacer amplitude, frequency, displacer/piston phase angle, dynamic deforming CFD grid, temperature boundary conditions, and user defined files describing motion profile of piston/displacer. The results of the model are temperature distributions, heat distributions, and PV power produced at pre-determined conditions.

Luis A Rodriguez↗

Experimental Creep Life Assessment for the Advanced Stirling Convertor Heater Head

The United States Department of Energy is planning to develop the Advanced Stirling Radioisotope Generator (ASRG) for the National Aeronautics and Space Administration (NASA) for potential use on future space missions. The ASRG provides substantial efficiency and specific power improvements over radioisotope power systems of heritage designs. The ASRG would use General Purpose Heat Source modules as energy sources and the free-piston Advanced Stirling Convertor (ASC) to convert heat into electrical energy. Lockheed Martin Corporation of Valley Forge, Pennsylvania, is integrating the ASRG systems, and Sunpower, Inc., of Athens, Ohio, is designing and building the ASC. NASA Glenn Research Center of Cleveland, Ohio, manages the Sunpower contract and provides technology development in several areas for the ASC. One area is reliability assessment for the ASC heater head, a critical pressure vessel within which heat is converted into mechanical oscillation of a displacer piston. For high system efficiency, the ASC heater head operates at very high temperature (850 C) and therefore is fabricated from an advanced heat-resistant nickel-based superalloy Microcast MarM-247. Since use of MarM-247 in a thin-walled pressure vessel is atypical, much effort is required to assure that the system will operate reliably for its design life of 17 years. One life-limiting structural response for this application is creep; creep deformation is the accumulation of time-dependent inelastic strain under sustained loading over time. If allowed to progress, the deformation eventually results in creep rupture. Since creep material properties are not available in the open literature, a detailed creep life assessment of the ASC heater head effort is underway. This paper presents an overview of that creep life assessment approach, including the reliability-based creep criteria developed from coupon testing, and the associated heater head deterministic and probabilistic analyses. The approach also includes direct benchmark experimental creep assessment. This element provides high-fidelity creep testing of prototypical heater head test articles to investigate the relevant material issues and multiaxial stress state. Benchmark testing provides required data to evaluate the complex life assessment methodology and to validate that analysis. Results from current benchmark heater head tests and newly developed experimental methods are presented. In the concluding remarks, the test results are shown to compare favorably with the creep strain predictions and are the first experimental evidence for a robust ASC heater head creep life.

Krause, David L.↗

Long-Term Assessment of Commercial Building Energy and Carbon Emissions in the Northwestern Region Under Future Weather Trend

The future climate significantly impacts building performance and increases uncertainties in energy simulations. A rising temperature trend is expected to heighten cooling loads during summer and result in more carbon emissions. Understanding the impact of future climate on building performance is significant for policymakers to make informed decisions. Building retrofit measures can improve building energy efficiency and reduce operational carbon emissions, yet their effects under future climate conditions have not been fully investigated so far. Thus, we proposed an assessment methodology for evaluating long-term energy consumption and operational carbon reduction potential using a building stock dataset. For this study, commercial buildings in the northwestern (NW) region were utilized to assess the impacts of future climate and building retrofit. In addition, we selected Montana with a cold and dry climate as an example to analyze and discuss the carbon emission reduction potential in buildings. The main findings are: (1) Under future climate trends, changes in energy use intensity (EUI) will fluctuate due to variations in heating and cooling degree-days (HDDs and CDDs) and increasing HDDs will lead to increasing EUI. (2) After applying annual building retrofitting, the long-term EUI reduction potential of buildings in the NW region will decrease with the increasing retrofitting degree, and the short-term EUI reduction potential will be impacted by the change of heating and cooling degree days. (3) In Montana, the long-term carbon intensity reduction potential of retrofitted buildings will decrease under future climate trends with the increasing renewable energy penetration.

building energy modeling↗

Low-Power, Load-Balancing Whole Home Electrification Solution: Cooperative Research and Development (Final Report)

Testing was conducted at the Systems Performance Laboratory in NREL’s Energy Systems Integration Facility to test the performance of 120V wall-mounted heat pumps, 120V heat pump water heaters (HPWH), Electric Vehicle Supply Equipment (EVSE), and other plug-in loads, using NeoCharge Smart Splitters and whole home energy software as appropriate. Four different simulated occupancy scenarios were used to evaluate the package of technology and controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermo-hydraulic steam pipe models for district heating simulations: Simplifications to balance accuracy and simulation speed

Steam piping networks are essential for optimizing performance in industrial processes and district heating systems. However, dynamic models that balance thermo-hydraulic accuracy with computational efficiency remain limited. In response, this paper presents a new discretized steam pipe model based on the plug flow approach, capturing key thermo-hydraulic behaviors while simplifying steam phase change processes. Implemented in Modelica, the model accurately calculates temperature and pressure distributions along steam pipelines. To improve computational efficiency for district-scale simulations, five model simplifications are introduced: lumped thermo-hydraulic functions, empirical correlations, fluid state approximations, steady-state dynamics and inclusion of flow derivatives. These simplified models achieve 85%-98% accuracy in predicting pressure drop and condensation losses, including dynamic condensate behavior during pipe warm-up—a factor often overlooked in existing models. The models support diverse network configurations, scaling effectively to systems with multiple distribution pipes and connected building loads. Discrete models provide detailed insights but exhibit a cubic increase in simulation time as the network scales by N connected building O(N 2.42 ). In contrast, lumped models simulate 10–28 times faster than discrete, offering quadratic scaling of simulation time O(N 1.73 ). However, they still require 6 times more computation time than a lossless network, highlighting the inherent computational challenges of modeling compressible fluid flow. In conclusion, the steady-state lumped variant, with its near-linear scalability in computational time O(N 1.01 ), emerges as an efficient solution for preliminary design evaluations and extensive parametric studies.

15 GEOTHERMAL ENERGY↗

Technology Development and Field Monitoring in nZEB - US Country report IEA HPT Annex 49 Task 3

The International Energy Agency (IEA) Heat Pumping Technologies (HPT) Annex 49, “Design and Integration of Heat Pumps for Nearly Zero Energy Buildings,” deals with the application of heat pumps (HPs) as a core component of the HVAC system for nearly or net-zero energy buildings. This report covers the Task 3 activities of the US team. Three institutions are involved on the US team and have worked on the following projects. 1) Oak Ridge National Laboratory (ORNL) summarized development activities since the conclusion of IEA HPT Annex 40 for several integrated HP (IHP) systems - electric ground-source IHP and air-source IHP versions and engine-driven AS-IHP version. 2) The University of Maryland partnered with ORNL and Blue Bear Management to develop a personal cooling device called RoCo that can provide personalized conditioned air to occupants in inadequately or unconditioned environments. With RoCo, building facility management can elevate the HVAC thermostat settings without compromising occupants’ thermal comfort. Researchers have found that a 4°F increase in thermostat settings can save 12–30% energy savings. Therefore, RoCo is a promising technology that can help reduce building energy consumption and facilitate achievement of net-zero energy building performance. 3) The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net-Zero Energy Residential Test Facility. Two air-source split-system HPs were installed in a residential, net-zero energy home that was constructed as a laboratory on the NIST campus in Gaithersburg, Maryland. The first HP was a two-stage, 7 kW (2 ton), 15.8 seasonal energy efficiency ratio (SEER), 9.05 heating seasonal performance factor (HSPF) conventionally ducted system; the second HP was a variable-speed, 10.6 kW (3 ton), 14 SEER, 8.35 HSPF, high-velocity ducted system. These two systems operated side by side, using separate supply ducts and a common return duct, on a weekly alternating schedule to condition the home that was operated with very consistent simulated thermal loads. The team wanted to determine whether the high-velocity system could provide comparable energy-use efficiency to the conventional system. The results of this study showed that it did meet the required loads and had slightly greater efficiency; the average cooling coefficient of performance (COP) was (0.40 ± 0.11) higher, and the average heating COP was statistically equal. A new firmware was provided at the end of the heating season that greatly improved the performance of the high-velocity system; its average heating COP went from (1.8 ± 0.9) to (2.5 ± 1.1) at a 95% confidence level. The new firmware heating COP averaged (1.05 ± 0.23) higher than the old firmware over the same outdoor temperatures. The defrost performance is very different for these two systems, yet they consumed equivalent energy per HDD. The conventional system uses a timed-initiate, temperature-terminate algorithm with auxiliary electric resistive heating, whereas the high-velocity system uses calculated evaporator parameters with a hot-gas bypass before a full reverse-cycle defrost with no supplementary resistive heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

North Carolina Water Utility Builds Resilience with Distributed Energy Resources

As the frequency and duration of grid outages increase, backup power systems are becoming more important for ensuring that critical infrastructure continues to provide essential services. Most facilities rely on diesel generators, which may be ineffective during long outages owing to limited fuel supplies and high generator failure rates. Distributed energy resources such as solar, storage, and combined-heat-and-power systems, coupled with on-site biofuel production, offer an alternative source of on-site generation that can provide both cost savings and resilience (i.e., the ability to respond to catastrophic events with longer-term consequences). A mixed-integer linear program minimizes costs and maximizes resilience at a wastewater treatment plant in Wilmington, North Carolina. We find that the plant can reduce life-cycle energy costs by 3.1% through the installation of a hybrid combined-heat-and-power, photovoltaic, and storage system. When paired with existing diesel generators, this system can sustain full load for seven days while saving $664,000 over 25 years and reducing diesel fuel use by 48% compared with the diesel-only solution. This analysis informed a decision by the Cape Fear Public Utility Authority to allocate funds for the implementation of a combined-heat-and-power system at the wastewater treatment plant in fiscal year 2023. Finally, the benefits of deploying hybrid combined-heat-and-power technologies and the utilization of on-site biofuel production extend, on a national scale, to thousands of wastewater treatment facilities and other types of critical infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a High Output Fluorescent Light Module for the Commercial Plant Biotechnology Facility

To maximize the use of available resources provided onboard the International Space Station, the development of an efficient lighting 1 system is critical to the overall performance of the CPBF. Not only is it important to efficiently generate photon energy, but thermal loads on the CPBF Temperature and Humidity Control System must be minimized. By utilizing optical coatings designed to produce highly diffuse reflectance in the visible wavelengths while minimizing reflectance in the infrared region, the design of the fluorescent light module for the CPBF is optimized for maximum photon flux, spatial uniformity and energy efficiency. Since the Fluorescent Light Module must be fully enclosed to meet (ISS) requirements for containment of particulates and toxic materials, heat removal from the lights presented some unique design challenges. By using the Express Rack moderate C, temperature-cooling loop, heat is rejected by means of a liquid/air coolant manifold. Heat transfer to the manifold is performed by conduction using copper fins, by forced air convection using miniature fans, and by radiation using optically selective coatings that absorb in the infrared wavelengths. Using this combination of heat transfer mechanisms builds in redundancy to prevent thermal build up and premature bulb failure.

Turner, Mark↗

Heat Pumps with Phase Change Thermal Storage: Flexible, Efficient, and Electrification Friendly

As we continue to electrify space- and water-heating, the electricity demand profile of many buildings will change significantly, and periods of high electricity demand will likely not align with renewable energy generation. We expect electricity demands will increase substantially in the winter, annual maximum electricity demands will increase, and more regions will experience annual peak electrical demands – and higher wholesale electricity prices – in the winter. This is especially important for cold climates where 60% of site energy use in buildings is for heating, and where heat pumps perform least efficiently. This paper focuses on one promising solution among the many paths to electrification: the use of phase change materials (PCM) for compact low-cost thermal energy storage (TES). We present the design and simulation of a combi heat pump and phase change thermal storage system used for space- and water-heating in a multifamily residence in a cold climate. To assess the benefits of this technology, we compare its annual performance to that of a current state-of-the-art air-to-air heat pump and separate heat pump water heater. Simulation results for IECC Climate Zone 6A reveal that the combi heat pump with phase change thermal storage can reduce the design size for heat pumps by 40-60%, reduce maximum electric demand by 30-50%, reduce electricity use during 4-12-hour load shed periods by 50%, and avoid the need for auxiliary electric resistance for both space- and water-heating. Tariff structures are highly varied between different utilities and currently reflect higher wholesale market prices for electricity during summer days. Consequently, although this system design provides large electric demand reductions during hypothetical 4-12-hour load shed periods, it does not provide energy cost reductions with current winter residential time-of-use tariffs.

Helmns, Dre↗

Co-Simulation of Electric Power Distribution Systems and Buildings including Ultra-Fast HVAC Models and Optimal DER Control

Smart homes and virtual power plant (VPP) controls are growing fields of research with potential for improved electric power grid operation. A novel testbed for the co-simulation of electric power distribution systems and distributed energy resources (DERs) is employed to evaluate VPP scenarios and propose an optimization procedure. DERs of specific interest include behind-the-meter (BTM) solar photovoltaic (PV) systems as well as heating, ventilation, and air-conditioning (HVAC) systems. The simulation of HVAC systems is enabled by a machine learning procedure that produces ultra-fast models for electric power and indoor temperature of associated buildings that are up to 133 times faster than typical white-box implementations. Hundreds of these models, each with different properties, are randomly populated into a modified IEEE 123-bus test system to represent a typical U.S. community. Advanced VPP controls are developed based on the Consumer Technology Association (CTA) 2045 standard to leverage HVAC systems as generalized energy storage (GES) such that BTM solar PV is better utilized locally and occurrences of distribution system power peaks are reduced, while also maintaining occupant thermal comfort. An optimization is performed to determine the best control settings for targeted peak power and total daily energy increase minimization with example peak load reductions of 25+%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar-assisted gas-energy water-heating feasibility for apartments

Studies of residential energy use, solar-energy technology for buildings, and the requirements for implementing technology in the housing industry led to a project to develop a solar water heater for apartments. A design study for a specific apartment was used to establish a solar water-heater cost model which is based on plumbing contractor bids and manufacturer estimates. The cost model was used to size the system to minimize the annualized cost of hot water. The annualized cost of solar-assisted gas-energy water heating is found to be less expensive than electric water heating but more expensive than gas water heating. The feasibility of a natural gas utility supplying the auxiliary fuel is evaluated. It is estimated that gas-utilizing companies will find it profitable to offer solar water heating as part of a total energy service option or on a lease basis when the price of new base-load supplies of natural gas reaches $2.50-$3.00 per million Btu.

Davis, E. S.↗