Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Stochastic Pricing Game for Aggregated Demand Response Considering Comfort Level

In recent years, demand response (DR) has been explored as a fundamental strategy for demand-side management due to its advantages in mediating intermittency of renewable energy generation, load shifting, etc. To engage customers in DR programs, several deterministic price-based DR strategies have been developed and implemented. However, the stochastic weather conditions and occupants' consumption behaviors often make the deterministic solution less robust to uncertainties. In this paper, with the consideration of the uncertainties, a stochastic Stackelberg game is proposed to model the price-demand negotiation between a distributed system operator and load aggregators, where the virtual battery constraints are extracted from the building thermostatically controlled loads (TCLs)‘ characteristics to guarantee comfortable TCLs' levels. Following the negotiation, a priority-based control method is used to allocate the optimal aggregated power DR profile at the building level and track the power signal. Several groups of experiments have demonstrated the effectiveness and robustness of the stochastic solutions.

Chen, Yang↗

Air quality and comfort constrained energy efficient operation of multi-zone buildings

Maintaining indoor air quality (IAQ) through effective ventilation is essential for the well-being and productivity of building occupants. Control strategies aimed at improving the efficiency of heating, ventilation and air conditioning (HVAC) systems must jointly determine ventilation and heating and cooling processes. Here, in this paper, we study the problem of minimizing the energy consumption of the HVAC system in a multi-zone building, while meeting thermal comfort and IAQ requirements. We first perform a steady state analysis of the zonal carbon dioxide (CO 2 ) concentration and the temperature dynamics. The resulting expressions are convex in the zonal mass flow rates and zonal temperatures. Guided by the steady state solutions for meeting the thermal comfort constraints, we develop two control policies for improving the energy efficiency of building HVAC systems while jointly satisfying indoor temperature and IAQ constraints. We compare the performance of our proposed approaches with those of multiple baseline approaches which implement separate regimes for controlling zonal temperature and IAQ for a typical work-day in a multi-zone campus building. We have evaluated the performance of our proposed approaches under varying levels of flexibility in zonal temperatures. We have shown that zonal temperature flexibility can result in energy savings up to 32% (for the same control strategies) as compared to the case where no such flexibility is permitted. Our proposed approaches were seen to offer potential savings of nearly 29% compared to the baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ten questions concerning integrating smart buildings into the smart grid

Recent advances in information and communications technology (ICT) have initiated development of a smart electrical grid and smart buildings. Buildings consume a large portion of the total electricity production worldwide, and to fully develop a smart grid they must be integrated with that grid. Buildings can now be 'prosumers' on the grid (both producers and consumers), and the continued growth of distributed renewable energy generation is raising new challenges in terms of grid stability over various time scales. Buildings can contribute to grid stability by managing their overall electrical demand in response to current conditions. Facility managers must balance demand response requests by grid operators with energy needed to maintain smooth building operations. For example, maintaining thermal comfort within an occupied building requires energy and, thus an optimized solution balancing energy use with indoor environmental quality (adequate thermal comfort, lighting, etc.) is needed. Successful integration of buildings and their systems with the grid also requires interoperable data exchange. However, the adoption and integration of newer control and communication technologies into buildings can be problematic with older legacy HVAC and building control systems. Public policy and economic structures have not kept up with the technical developments that have given rise to the budding smart grid, and further developments are needed in both technical and non-technical areas.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HVAC and Control Templates for the Modelica Buildings Library

This article reports on our experience in creating Modelica models for systems with thousands of configurations and closed-loop controls. The development of such templates required exploration of class parameterization techniques and data structures for handling large sets of equipment parameters. By describing these issues and the approach taken, we show how the Modelica language can support advanced templating logic. The main limitation we encountered relates to parameter assignment and propagation. The interpretation of parameter attributes at user interface runtime, or the handling of non-trivial constructs involving record classes at compile time is not consistently supported by Modelica tools. This leads to choices that are difficult to make when looking for a generic implementation.

Gautier, Antoine↗

Development of a simplified calibrated building simulation model of a supermarket for proposed ECMs and control strategies impact evaluation

Calibrated building energy simulation is an important pathway to more energy-efficient buildings, but the information requirements of some approaches to this problem are significant. This is particularly true for supermarkets and other so-called “big-box” retail stores. Another characteristic of supermarkets is the significant interaction between Heating Ventilating and Air Conditioning (HVAC) and refrigeration systems in these buildings. These buildings could contain a wide variety of systems and a degree of load diversity that makes calibrated modeling a challenge. This paper describes a simplified approach that uses OpenStudio and EnergyPlus to combine known building parameters with “typical” parameters, resulting in a simplified building that is amenable to calibration. This approach was applied to a big-box store located in Nashville, Tennessee, and a calibrated model was obtained that was used to study potential energy conservation measures. Further, the paper also explores the capabilities of whole-building energy modeling tools, such as EnergyPlus, for modeling the HVAC controls and sequences and their impact evaluation. Although some measures are precluded by the model simplicity, several measures were found to improve the efficiency of the model and demonstrate that the simplified modeling approach is effective. Practical Application: This paper introduces a hybrid approach of building energy model calibration using limited information available from the actual building in combination with characteristics of a “typical” building of the same type. This hybrid approach would also be applicable for other building types than discussed in this paper to calibrate the building energy model using limited information from the actual building.

42 ENGINEERING↗

Baseline Validation of Unstructured Grid Reynolds-Averaged Navier-Stokes Toward Flow Control

The value of the use of the Reynolds-averaged Navier-Stokes methodology for active flow control applications is assessed. An experimental flow control database exists for a NACA0015 airfoil modified at the leading edge to implement a fluidic actuator; hence, this configuration is used. Computational results are documented for the baseline wing configuration (no control) with the experimental results and assumes two-dimensional flow. The baseline wing configuration has discontinuities at the leading edge, trailing edge, and aft of midchord on the upper surface. A limited number of active flow control applications have been tested in the laboratory and in flight. These applications include dynamic stall control using a deformable leading edge, separation control for takeoff and landing flight conditions using piezoelectric devices, pulsed vortex generators, zero-net-mass oscillations, and thrust vectoring with zero-net-mass piezoelectric-driven oscillatory actuation. As yet, there is no definitive comparison with experimental data that indicates current computational capabilities can quantitatively predict the large aerodynamic performance gains achieved with active flow control in the laboratory. However, one study using the Reynolds-averaged Navier-Stokes (RANS) methodology has shown good quantitative agreement with experimental results for an isolated zero-net-mass actuator. In addition, some recent studies have used RANS to demonstrate qualitative performance gains compared with the experimental data for separation control on an airfoil. Those quantitative comparisons for both baseline and flow control cases indicated that computational results were in poor quantitative agreement with the experiments. The current research thrust will investigate the potential use of an unstructured grid RANS approach to predict aerodynamic performance for active flow control applications building on the early studies. First the computational results must quantitatively match experiments for the no-control case before proceeding to the time-dependent flow control case. This paper documents the baseline (no-control) case using an unswept airfoil configuration. The next section describes the configurations used for the computations and the experimentals. The computational approach is then described followed by results and concluding remarks.

Joslin, Ronald D.↗

Wireless Sensor Networks: Monitoring and Control

The article discusses wireless sensor technologies for building energy monitoring and control. This article, also, addresses wireless sensor networks as well as benefits and challenges of using wireless sensors. The energy savings and market potential of wireless sensors are reviewed.

ASHRAE↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

STTR Phase I: Low-Cost, High-Accuracy, Whole-Building Carbon Dioxide Monitoring for Demand Control Ventilation

This STTR Phase I project assessed the feasibility of a new CO 2 sensing system optimized for low-cost, high-accuracy, whole-building monitoring for use in demand control ventilation. The focus was on the development of a wireless networking platform and associated firmware to provide signal conditioning and conversion, fault- and disruptiontolerant networking, and multi-hop routing at building scales to avoid wiring costs. Early exploration of a bridge (or “gateway”) to direct digital control services was also explored. Results of the project contributed to an improved understanding of a new electrochemical sensor for monitoring indoor CO 2 concentrations, as well as the electronics and networking infrastructure required to deploy those sensors at building scales. New knowledge was acquired concerning the sensor’s accuracy, environmental response, and failure modes, and the acquisition electronics required to achieve accuracy over a wide range of CO 2 concentrations. The project demonstrated that the new sensor offers repeatable correspondence with commercial optical sensors, with supporting electronics that offer gain accuracy within 0.5%, and acquisition accuracy within 1.5% across three orders of magnitude variation in generated current. Considering production, installation, and maintenance costs, the technology presents a foundation for achieving whole-building CO 2 sensing at a price point below $0.066 / sq-ft – meeting economic feasibility criteria established by the Department of Energy. The technology developed under this award addresses obstacles on the critical path to enabling whole-building CO 2 sensing and demand control ventilation in commercial retrofits, small commercial buildings, residential complexes, and other highpotential structures that have been slow to adopt these technologies. It presents an opportunity to significantly reduce energy use throughout the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mission Control Technologies: A New Way of Designing and Evolving Mission Systems

Current mission operations systems are built as a collection of monolithic software applications. Each application serves the needs of a specific user base associated with a discipline or functional role. Built to accomplish specific tasks, each application embodies specialized functional knowledge and has its own data storage, data models, programmatic interfaces, user interfaces, and customized business logic. In effect, each application creates its own walled-off environment. While individual applications are sometimes reused across multiple missions, it is expensive and time consuming to maintain these systems, and both costly and risky to upgrade them in the light of new requirements or modify them for new purposes. It is even more expensive to achieve new integrated activities across a set of monolithic applications. These problems impact the lifecycle cost (especially design, development, testing, training, maintenance, and integration) of each new mission operations system. They also inhibit system innovation and evolution. This in turn hinders NASA's ability to adopt new operations paradigms, including increasingly automated space systems, such as autonomous rovers, autonomous onboard crew systems, and integrated control of human and robotic missions. Hence, in order to achieve NASA's vision affordably and reliably, we need to consider and mature new ways to build mission control systems that overcome the problems inherent in systems of monolithic applications. The keys to the solution are modularity and interoperability. Modularity will increase extensibility (evolution), reusability, and maintainability. Interoperability will enable composition of larger systems out of smaller parts, and enable the construction of new integrated activities that tie together, at a deep level, the capabilities of many of the components. Modularity and interoperability together contribute to flexibility. The Mission Control Technologies (MCT) Project, a collaboration of multiple NASA Centers, led by NASA Ames Research Center, is building a framework to enable software to be assembled from flexible collections of components and services.

Trimble, Jay↗

Unified Optimization Of A Structure And Its Control System

Method for unified optimization of structure and its vibration-suppressing control system involves extension of established techniques of optimization via approach based on homotopy, in which cost function used as criterion for optimization of control system coupled to corresponding cost function of structure via new parameter. Applicable to such terrestrial problems as designing buildings with control actuators to prevent damage by earthquakes.

Milman, Mark H.↗

Empowering Energy Efficiency in Existing Big-Box Retail/Grocery Stores (Final Optimization Report)

The Center for Sustainable Energy (CSE), in partnership with the National Renewable Energy Laboratory (NREL), TRC Energy Services, P2S Engineering Inc, Walmart, and five innovative technology providers, are to demonstrate the impact of an integrated suite of pre-commercial energy efficiency (EE) technologies in a large, existing, retail building located within an inland disadvantaged community. Proposed technology packages include three categories of advanced EE solutions: heating, ventilating, air-conditioning, and refrigerating (HVAC/R); lighting; and integrated system and building level controls. The project is designed to impact Walmart’s future store specifications, which can be replicated and deployed in other buildings across California with similar end-use and system characteristics. The following lists the technologies considered for this project: DualCool (HVAC evaporative cooling); Software Motor Company (SMC) (HVAC and refrigeration fan motor); I2S: DC LED lighting; LocBit: building energy management and optimization; Saya: water monitoring.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Distributed model predictive control for coordinated, grid-interactive buildings

Continued focus on reducing carbon emissions and improving energy efficiency requires buildings to become grid-interactive and not just behave as static consumers. A distributed model predictive control (DMPC) algorithm known as Limited-Communication (LC) DMPC is modified to enable grid-interactive buildings. A grid-aggregator subsystem is added that allows for a bulk grid power reference signal to be followed while the individual building subsystems also achieve their local comfort objectives. The LC-DMPC algorithm is applied for the first time to systems with multiple buildings. Adequate power tracking is shown for different simulation scenarios involving heterogeneous buildings, and next steps are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modelica-json: Transforming energy models to digitize the control delivery process

Building simulation models are typically not used to generate the documentation required for bidding and project delivery of commercial building systems, or for their semantic modeling and commissioning. This paper presents a software tool that aids in digitizing the control delivery process, spanning simulation during design to implementation and formal verification during commissioning. The tool can generate from Modelica models digital documentation of control sequences. This digital documentation, along with other project drawings and specifications can be used for project bidding. It can also be used for implementation of control sequences through machineto-machine translation to commercial legacy control products, for which we are currently developing the proposed ASHRAE Standard 231P based on the presented work. Moreover, as-installed control sequences can be formally verified against the design specification, and a semantic model in Brick can be exported to aid in configuration of building analytics and fault detection. The paper presents what we believe is the first translation of a Modelica-implemented control sequence to a native implementation on a commercial control platform, using the webCTRL product line from Automated Logic. The paper also shows how a webCTRL implementation can be formally verified against its Modelica specification. These use cases have all been demonstrated with a prototype implementation that is now being further developed.

Wetter, Michael↗

Metering Best Practices Applied in the National Renewable Energy Laboratory's Research Support Facility: A Primer to the 2011 Measured and Modeled Energy Consumption Datasets

Modern buildings are complex energy systems that must be controlled for energy efficiency. The Research Support Facility (RSF) at the National Renewable Energy Laboratory (NREL) has hundreds of controllers -- computers that communicate with the building's various control systems -- to control the building based on tens of thousands of variables and sensor points. These control strategies were designed for the RSF's systems to efficiently support research activities. Many events that affect energy use cannot be reliably predicted, but certain decisions (such as control strategies) must be made ahead of time. NREL researchers modeled the RSF systems to predict how they might perform. They then monitor these systems to understand how they are actually performing and reacting to the dynamic conditions of weather, occupancy, and maintenance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Condensing Boilers - Optimizing Efficiency and Response Time During Setback Operation

Conventional wisdom surrounding space heating has told us a couple of things consistently for several years now: size the mechanical systems to the heating loads and setting the thermostat back at night will result in energy savings. The problem is these two recommendations oppose each other. A system that is properly sized to the heating load will not have the extra capacity necessary to recover from a thermostat setback, especially at design conditions. The implication of this is that, for setback to be successfully implemented, the heating system must be oversized. This issue is exacerbated further when an outdoor reset control is used with a condensing boiler, because not only is the system matched to the load at design, the outdoor reset control matches the output to the load under varying outdoor temperatures. Under these circumstances, the home may never recover from setback. Special controls to bypass the outdoor reset sensor are then needed. Properly designing a hydronic system for setback operation can be accomplished but depends on several factors. Determining the appropriateness of setback for a particular project is the first step. This is followed by proper sizing of the boiler and baseboard to ensure the needed capacity can be met. Finally, control settings must be chosen that result in the most efficient and responsive performance. This guide provides step by step instructions for heating contractors and hydronic designers for selecting the proper control settings to maximize system performance and improve response time when using a thermostat setback.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Passivity analysis for a winged re-entry vehicle

Application of simple adaptive control (SAC) theory to the design of guidance and control systems for winged re-entry vehicles has been proven successful. To apply SAC to these non-linear and non-stationary systems, it needs to be Almost Strictly Passive (ASP), which is an extension of the Almost Strictly Positive Real (ASPR) condition for linear, time-invariant systems. To fulfill the ASP condition, the controlled, non-linear system has to be minimum-phase (i.e., the zero dynamics is stable), and there is a specific condition for the product of output and input matrix. Earlier studies indicate that even the linearised system is not ASPR. The two problems at hand are: 1) the system is non-minimum phase when flying with zero bank angle, and 2) whenever there is hybrid control, e.g., yaw control is established by combined reaction and aerodynamic control for the major part of flight, the second ASPR condition cannot be met. In this paper we look at both issues, the former related to the guidance system and the latter to the attitude-control system. It is concluded that whenever the nominal bank angle is zero, the passivity conditions can never be met, and guidance should be based on nominal commands and a redefinition of those whenever the error becomes too large. For the remaining part of the trajectory, the passivity conditions are marginally met, but it is proposed to add feedforward compensators to alleviate these conditions. The issue of hybrid control is avoided by redefining the controls with total control moments and adding a so-called control allocator. Deriving the passivity conditions for rotational motion, and evaluating these conditions along the trajectory shows that the (non-linear) winged entry vehicle is ASP. The sufficient conditions to apply SAC for attitude control are thus met.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of CNT Energy Savers Retrofit Packages Implemented in Multifamily Buildings

This evaluation explored the feasibility of designing prescriptive retrofit measure packages for typical Chicago region multifamily buildings in order to achieve 25%-30% source energy savings through the study of three case studies. There is an urgent need to scale up energy efficiency retrofitting of Chicago's multifamily buildings in order to address rising energy costs and a rapidly depleting rental stock. Aimed at retrofit program administrators and building science professionals, this research project investigates the possibility of using prescriptive retrofit packages as a time- and resource-effective approach to the process of retrofitting multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗