Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Experimental investigation on thermal inertia characterization of commercial buildings for demand response

Characterizing the thermal inertia of commercial buildings is of great importance in quantifying demand flexibility. Experimental tests can be used to investigate the thermal inertia of commercial buildings. However, existing studies tend to be qualitative and have limited scope. In this study, a comprehensive field test has been performed to assess the thermal inertia of commercial buildings. In this field test, six buildings are selected with different sizes, vintages, and types of heating, ventilation, and air conditioning (HVAC) systems to represent the majority of the U.S. commercial building stock. We quantify the thermal inertia with building operation data collected under various thermostat excitation signals. We then studied the relationship between thermal inertia and intrinsic properties, such as floor area, HVAC system, etc., as well as the operation condition indicators such as outdoor air temperature, zone temperature, and occupancy. The testing results indicate that the median values of the normalized charge response time and the normalized discharge response time of the five buildings are 1~5 hr/ °C and -5~-1 hr/ °C, respectively. The results also show that the thermal inertia of commercial buildings may be sensitive to the HVAC system type but not the floor area or location of zones, i.e., core vs. perimeter. Finally, our results suggest that the relationships between the charging/discharging normalized response time and the zone/outdoor temperature may vary among zones and be highly nonlinear.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

OpenADR Specification to Ease Saving Power in Buildings

A new data model developed by researchers at the Department of Energys Lawrence Berkeley National Laboratory and their colleagues at other universities and in the private sector will help facilities and buildings save power through automated demand response technology, and advance the development of the Smart Grid. http://newscenter.lbl.gov/press-releases/2009/04/27/openadr-specification/

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Bayesian model for multivariate discrete data using spatial and expert information with application to inferring building attributes

When modeling sparsely observed multivariate data, strong prior information elicited from experts can be used to bolster predictive accuracy and counteract sampling bias. Similarly, modeling autocorrelation in space can help make use of co-occurrence patterns present in many types of spatial data. To make use of both expert prior information and spatial structure, we propose a novel graphical model for a spatial Bayesian network developed specifically to address challenges in inferring the attributes of buildings from geographically sparse observational data. This model is implemented as the sum of a spatial multivariate Gaussian random field and a tabular conditional probability function in real-valued space prior to projection onto the probability simplex. This modeling form is especially suitable for the usage of prior information in the form of sets of atomic rules obtained from experts. To perform inference with missing data, we implement a Markov chain Monte Carlo scheme composed of alternating steps of Gibbs sampling of missing entries and Hamiltonian Monte Carlo for model parameters. A case study in building attribution is presented to highlight the advantages and limitations of this approach.

97 MATHEMATICS AND COMPUTING↗

Big Data Mining for Assessing Calibration of Building Energy Models

Residential and commercial buildings in China, India, the United States (US), United Kingdom (UK), and Italy consume 39-45% of each nation's primary energy. Building energy models can be used to automatically optimize the return-on-investment for retrofits to improve a building’s energy efficiency. However, with an average of 3,000 building descriptors necessary to accurately simulate a single building, there is a market need to reduce the transaction cost for creating a more robust model for simulating every building in a city and accurately estimate savings prior to capital expenditures.We used two of the world’s fastest supercomputers, assembled unique datasets, and developed innovative algorithms for big data mining to assess different methods to create an accurate building energy model. The team has leveraged a total of eight high performance computing resources and 218 servers to analyze the best methods, metrics, and algorithms for creating an accurate building energy model beyond current industry standards necessary for private-sector financing. The project developed the world’s fastest buildings simulator, has completed over 8 million simulations totaling over 300TB, and mined this data with over 130,000 parallel artificial intelligence algorithms. This was used to quantify accuracy of AI-developed calibration algorithms with results that surpass industry standard guidelines and can identify individual building parameters to between 15% and 32% of their actual value.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Bayesian Inference Framework towards Identifying Gas Species and Concentration from High Temperature Resistive Sensor Array Data

High temperature gas sensors have been highly demanded for combustion process optimization and toxic emissions control, which usually suffer from poor selectivity. In order to solve this selectivity issue and identify unknown reducing gas species (CO, CH 4 , and CH 8 ) and concentrations, a high temperature resistive sensor array data set was built in this study based on 5 reported sensors. As each sensor showed specific responses towards different types of reducing gas with certain concentrations, based on which calibration curves were fitted, providing benchmark sensor array response database, then Bayesian inference framework was utilized to process the sensor array data and build a sample selection program to simultaneously identify gas species and concentration, by formulating proper likelihood between input measured sensor array response pattern of an unknown gas and each sampled sensor array response pattern in benchmark database. This algorithm shows good robustness which can accurately identify gas species and predict gas concentration with a small error of less than 10% based on limited amount of experiment data. These features indicate that Bayesian probabilistic approach is a simple and efficient way to process sensor array data, which can significantly reduce the required computational overhead and training data.

Liu, Yixin↗

Electrification Futures Study Technology Data

This data supplements the "Electrification Futures Study: End-Use Electric Technology Cost and Performance Projections through 2050" report. The data included here consist of the cost and performance estimates for electric end-use technologies developed for the three sensitivity cases in the Electrification Futures Study: Slow Advancement, Moderate Advancement, and Rapid Advancement.

buildings↗

Optimization of Window Positions for Wind-Driven Natural Ventilation Performance

This paper optimizes opening positions on building facades to maximize the natural ventilation’s potential for ventilation and cooling purposes. The paper demonstrates how to apply computational fluid dynamics (CFD) simulation results to architectural design processes, and how the CFD-driven decisions impact ventilation and cooling: (1) background: A CFD helps predict the natural ventilation’s potential, the integration of CFD results into design decision-making has not been actively practiced; (2) methods: Pressure data on building facades were obtained from CFD simulations and mapped into the 3D modeling environment, which were then used to identify optimal positions of two openings of a zone. The effect of the selected opening positions was validated with building energy simulations; (3) results: The cross-comparison study of different window positions based on different geographical locations quantified the impact on natural ventilation effectiveness; and (4) conclusions: The optimized window position was shown to be effective, and some optimal solutions contradicted the typical cross-ventilation strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental and Modeled Assessment of Interventions to Reduce PM2.5 in a Residence during a Wildfire Event

Increasingly large and frequent wildfires affect air quality even indoors by emitting and dispersing fine/ultrafine particulate matter known to pose health risks to residents. With this health threat, we are working to help the building science community develop simplified tools that may be used to estimate impacts to large numbers of homes based on high-level housing characteristics. In addition to reviewing literature sources, we performed an experiment to evaluate interventions to mitigate degraded indoor air quality. We instrumented one residence for one week during an extreme wildfire event in the Pacific Northwest. Outdoor ambient concentrations of PM2.5 reached historic levels, sustained at over 200 μg/m3 for multiple days. Outdoor and indoor PM2.5 were monitored, and data regarding building characteristics, infiltration, and mechanical system operation were gathered to be consistent with the type of information commonly known for residential energy models. Two conditions were studied: a high-capture minimum efficiency rated value (MERV 13) filter integrated into a central forced air (CFA) system, and a CFA with MERV 13 filtration operating with a portable air cleaner (PAC). With intermittent CFA operation and no PAC, indoor corrected concentrations of PM2.5 reached 280 μg/m3, and indoor/outdoor (I/O) ratios reached a mean of 0.55. The measured I/O ratio was reduced to a mean of 0.22 when both intermittent CFA and the PAC were in operation. Data gathered from the test home were used in a modeling exercise to assess expected I/O ratios from both interventions. The mean modeled I/O ratio for the CFA with an MERV 13 filter was 0.48, and 0.28 when the PAC was added. The model overpredicted the MERV 13 performance and underpredicted the CFA with an MERV 13 filter plus a PAC, though both conditions were predicted within 0.15 standard deviation. The results illustrate the ways that models can be used to estimate indoor PM2.5 concentrations in residences during extreme wildfire smoke events.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Multi-fidelity physics-informed machine learning for probabilistic damage diagnosis

Machine learning (ML) models are gaining popularity in structural health monitoring (SHM) because of their ability to learn the complex relationship between damage and sensor data. However, the lack of sufficient experimental data for structures with different degrees of damage is a key problem in training ML models for SHM. This problem can be alleviated by using physics-based models to generate the required training data to build physics-informed ML (PIML) models for SHM. However, it takes significant computational effort to perform enough high-fidelity simulations of the diagnostic test. It is thus desirable to know whether the available computational resource budget should be expended on numerous low-fidelity physics simulations, or a small number of high-fidelity simulations, or their combination. In this paper, we investigate this aspect of generating adequate training data for PIML, by constructing multi-fidelity PIML models. We evaluate the performance of several PIML models, trained with different amounts of low-fidelity and high-fidelity data, in locating hidden cracks in concrete structures using a nonlinear dynamics-based diagnosis technique. Here, we find that high-fidelity physics simulations that do not cover the (test and damage) parameter space do not improve the performance of diagnostic PIML models built using data from many low-fidelity physics simulations.

42 ENGINEERING↗

Completion design improvement using a deep convolutional network

Maximizing stimulated natural and hydraulic fracture network is one of the primary hydraulic fracturing concerns for economic production from a horizontal shale gas well. Geomechanical facies and preexisting fractures in each stage are identified based on similarities in formation characteristics to optimize the locations of perforation clusters. This often requires analyzing large volumes of drilling, Logging While Drilling (LWD) and Measurement While Drilling (MWD) data. In this paper, we develop a methodology that calculates the mechanical specific energy (MSE) using real-time drill string acceleration signals directly from its definition. High resolution vibration signals have been collected using a tri-axial accerlometer, which was an auxiliary tool included in acoustic borehole imager. This technique provides a cost-efficient solution for engineered completion design. Furthermore, we adopt deep Convolutional Neural Network (CNN) with signal processing to build a data pipeline that effectively extracts patterns from dynamic acceleration signals for rock lateral MSE classification. First, we apply discrete wavelet transform and Short-Time Fourier Transform (STFT) for signal denoising and pattern recognition. Then we construct an image dataset using multi-scale image fusion at pixel level from 3 sensor channels, including axial, lateral acceleration spectrograms and zero-padded revolutions per minute (RPM). The resulted RGB image dataset includes 4,000 images of 5 MSE ranges with various rock strength conditions. Our results demonstrate that the proposed deep learning model can achieve more than 90% classification accuracy. The deep learning results, as a reference source, were applied in selected Marcellus Shale Energy and Environmental Lab (MSEEL) wells engineered completion located in the Marcellus shale gas site.

03 NATURAL GAS↗

A First–Principles–Based Sub–Lattice Formalism for Predicting Off–Stoichiometry in Materials for Solar Thermochemical Applications: The Example of Ceria

Theoretical models that reliably can predict off-stoichiometry in materials via accurate descriptions of underlying thermodynamics are crucial for energy applications. For example, transition-metal and rare-earth oxides that can tolerate a large number of oxygen vacancies, such as CeO 2 and doped CeO 2 , can split water and carbon dioxide via a two-step, oxide-based solar thermochemical (STC) cycle. The search for new STC materials with a performance superior to that of state-of-the-art CeO 2 can benefit from predictions accurately describing the thermodynamics of oxygen vacancies. The sub-lattice formalism, a common tool used to fit experimental data and build temperature-composition phase diagrams, can be useful in this context. Here, sub-lattice models are derived solely from zero-temperature quantum mechanics calculations to estimate fairly accurate temperature- and oxygen-partial-pressure-dependent off-stoichiometries in CeO 2 and Zr-doped CeO 2 . Physical motivations for deriving some of the “excess” sub-lattice model parameters directly from quantum mechanical calculations, instead of fitting to minimize deviations from experimental and/or theoretical data, are identified. As a result, important limitations and approximations of the approach used are specified and extensions to multi-cation oxides are also suggested to help identify novel candidates for water and carbon dioxide splitting and related applications.

08 HYDROGEN↗

A Comparison of Cosmological Parameters Determined from CMB Temperature Power Spectra from the South Pole Telescope and the Planck Satellite

The Planck cosmic microwave background temperature data are best fit with a Lambda CDM model that mildly contradicts constraints from other cosmological probes. The South Pole Telescope (SPT) 2540 deg(2) SPT-SZ survey offers measurements on sub-degree angular scales (multipoles 650 <= l <= 2500) with sufficient precision to use as an independent check of the Planck data. Here we build on the recent joint analysis of the SPT-SZ and Planck data in Hou et al. by comparing Lambda CDM parameter estimates using the temperature power spectrum from both data sets in the SPT-SZ survey region. We also restrict the multipole range used in parameter fitting to focus on modes measured well by both SPT and Planck, thereby greatly reducing sample variance as a driver of parameter differences and creating a stringent test for systematic errors. We find no evidence of systematic errors from these tests. When we expand the maximum multipole of SPT data used, we see low-significance shifts in the angular scale of the sound horizon and the physical baryon and cold dark matter densities, with a resulting trend to higher Hubble constant. When we compare SPT and Planck data on the SPT-SZ sky patch to Planck full-sky data but keep the multipole range restricted, we find differences in the parameters n(s) and A(s)e(-2 tau). We perform further checks, investigating instrumental effects and modeling assumptions, and we find no evidence that the effects investigated are responsible for any of the parameter shifts. Taken together, these tests reveal no evidence for systematic errors in SPT or Planck data in the overlapping sky coverage and multipole range and at most weak evidence for a breakdown of Lambda CDM or systematic errors influencing either the Planck data outside the SPT-SZ survey area or the SPT data at l > 2000.

Aylor, K.↗

Error-Induced Beam Degradation in Fermilab's Accelerators

In Part I, three independent models of Fermilab's Booster synchrotron are presented. All three models are constructed to investigate and explore the effects of unavoidable machine errors on a proton beam under the influence of space-charge effects. The first is a stochastic noise model. Electric current fluctuations arising from power supplies are ubiquitous and unavoidable and are a source of instabilities in accelerators of all types. A new noise module for generating the Ornstein-Uhlenbeck (O-U) stochastic noise is first created and incorporated into the existing Object-oriented Ring Beam Injection and Tracking (ORBIT-FNAL) package. After being convinced with a preliminary model that the noise, particularly non-white noise, does matter to beam quality, we proceeded to measure directly current ripples and common-mode voltages from all four Gradient Magnet Power Supplies (GMPS). Then, the current signals are Fourier-analyzed. Based upon the power spectra of current signals, we tune up the Ornstein-Uhlnbeck noise model. As a result, we are able to closely match the frequency spectra between current measurements and the modeled O-U stochastic noise. The stochastic noise modeled upon measurements is applied to the Booster beam in the presence of the full space-charge effects. This noise model, accompanied by a suite of beam diagnostic calculations, manifests that the stochastic noise, impinging upon the beam and coupled to the space-charge effects, can substantially enhance the beam degradation process throughout the injection period. The second model is a magnet misalignment model. It is the first time to utilize the latest beamline survey data for building a magnet-by-magnet misalignment model. Given as-found survey fiducial coordinates, we calculate all types of magnet alignment errors (station error, pitch, yaw, roll, twists, etc.) are implemented in the model. We then follow up with statistical analysis to understand how each type of alignment errors are currently distributed around the Booster ring. The ORBIT-FNAL simulations with space charge included show that rolled magnets, in particular, have substantial effects on the Booster beam. This survey-data-based misalignment model can predict how much improvement in machine performance can be achieved if prioritized or selected realignment work is done. In other words, this model can help us investigate different realignment scenarios for the Booster. In addition, by calculating average angular kicks from all misaligned magnets, we expect this misalignment model to serve as guidelines for resetting the strengths of corrector magnets. The third model for the Booster is a time-structured multi-turn injection model. Microbunch-injection scenarios with different time structures are explored in the presence of longitudinal space-charge force. Due to the radio-frequency (RF) bucket mismatch between the Booster and the 400-MeV transferline, RF-phase offsets can be parasitically introduced during the injection process. Using the microbunch multiturn injection, we carry out ESME-ORBIT-combined simulations. This combined simulation allows us to investigate realistic charge-density distribution under full space-charge effects. The growth rates of transverse emittances turned out to be 20 % in both planes. This microbunch-injection scenarios is also applicable to the future 8-GeV Superconducting Linac Proton Driver and the upgraded Main Injector at Fermilab. In Part II, the feasibility of momentum-stacking method of proton beams is investigated. When the Run2 collider program at Fermilab comes to an end around year 2009, the present antiproton source can be available for other purposes. One possible application is to convert the antiproton accumulator to a proton accumulator, so that the beam power from the Main Injector could be enhanced by a factor of four. Through adiabatic processes and optimized parameters of synchrotron motion, we demonstrate with an aid of the ESME code that up to four proton batches can be stacked in the momentum acceptance available for the Accumulator ring. This momentum-stacking method is expected to be a part of Fermilab's SuperNuMI (SNuMI) project.

43 PARTICLE ACCELERATORS↗

Quantitative assessment of fitting errors associated with streak camera noise in Thomson scattering data analysis

Thomson scattering measurements in high energy density experiments are often recorded using optical streak cameras. In the low-signal regime, noise introduced by the streak camera can become an important and sometimes the dominant source of measurement uncertainty. In this paper, we present a formal method of accounting for the presence of streak camera noise in our measurements. We present a phenomenological description of the noise generation mechanisms and present a statistical model that may be used to construct the covariance matrix associated with a given measurement. This model is benchmarked against simulations of streak camera images. We demonstrate how this covariance may then be used to weight fitting of the data and provide quantitative assessments of the uncertainty in the fitting parameters determined by the best fit to the data and build confidence in the ability to make statistically significant measurements in the low-signal regime, where spatial correlations in the noise become apparent. These methods will have general applicability to other measurements made using optical streak cameras.

47 OTHER INSTRUMENTATION↗

Analysis of radiant cooling system integrated with cooling tower for composite climatic conditions

Increased demand for cooling leads to consumption of a significant amount of energy by heating, ventilation, and air conditioning (HVAC) systems in buildings. Building envelope acts as a thermal barrier and plays a significant role in improving building energy efficiency. Radiant cooling systems often utilize building structure in the form of thermal storage and provide thermal comfort. The radiant cooling system has the potential of saving peak power in the buildings. In present study experimental and a simulation study is performed for chiller and cooling tower integrated chilled ceiling radiant cooling system for chilled water source and a parallel dedicated outdoor air system (DOAS) is used for providing latent load and fresh air requirements of the zone. Cooling tower based radiant cooling system is compared with a chiller-based radiant cooling system for achieving annual energy saving. Experiments are conducted for the chiller and cooling tower operated radiant cooling system. Based on experimental data, whole building simulation models of both cooling tower and chiller-based systems were calibrated. For both the simulation model of chiller and cooling tower operated radiant cooling system simulation were carried out for round the year. The annual simulation results show that the cooling tower operated radiant cooling system saves 14% energy as compared to the chilled water operated radiating cooling system.

Srivastava, Prateek↗

Data-driven key performance indicators and datasets for building energy flexibility: A review and perspectives

Energy flexibility, through short-term demand-side management (DSM) and energy storage technologies, is now seen as a major key to balancing the fluctuating supply in different energy grids with the energy demand of buildings. This is especially important when considering the intermittent nature of ever-growing renewable energy production, as well as the increasing dynamics of electricity demand in buildings. This paper provides a holistic review of (1) data-driven energy flexibility key performance indicators (KPIs) for buildings in the operational phase and (2) open datasets that can be used for testing energy flexibility KPIs. The review identifies a total of 48 data-driven energy flexibility KPIs from 87 recent and relevant publications. These KPIs were categorized and analyzed according to their type, complexity, scope, key stakeholders, data requirement, baseline requirement, resolution, and popularity. Moreover, 330 building datasets were collected and evaluated. Of those, 16 were deemed adequate to feature building performing demand response or building-to-grid (B2G) services. The DSM strategy, building scope, grid type, control strategy, needed data features, and usability of these selected 16 datasets were analyzed. This review reveals future opportunities to address limitations in the existing literature: (1) developing new data-driven methodologies to specifically evaluate different energy flexibility strategies and B2G services of existing buildings; (2) developing baseline-free KPIs that could be calculated from easily accessible building sensors and meter data; (3) devoting non-engineering efforts to promote building energy flexibility, standardizing data-driven energy flexibility quantification and verification processes; and (4) curating and analyzing datasets with proper description for energy flexibility assessm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

OpenADR Specification to Ease Saving Power in Buildings

A new data model developed by researchers at the Department of Energy's Lawrence Berkeley National Laboratory and their colleagues at other universities and in the private sector will help facilities and buildings save power through automated demand response technology, and advance the development of the Smart Grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards the Net-Zero Data Center: Development and Application of an Energy Reuse Metric

Data Centers are an ever increasing user of energy in our economy. While the performance per watt of our IT equipment continues to increase exponentially, this energy performance improvement is still outstripped by increasing demand. Because of this, the efficiency of data centers must continue to improve. Beyond just efficiency, many data centers now are working towards reuse of their waste energy in other areas in the data center or on the site or campus. How to account for this, through metrics and measurements, is the topic of this paper. The Energy Reuse Effectiveness metric or ERE is discussed; both the development and application of the metric are looked at in detail. The use of ERE in conjunction with PUE (Power Usage Effectiveness) is also considered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗