Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Dose–Volume Relationships Associated With Temporal Lobe Radiation Necrosis After Skull Base Proton Beam Therapy

Purpose: We evaluated patient and treatment parameters correlated with development of temporal lobe radiation necrosis. Methods and Materials: This was a retrospective analysis of a cohort of 66 patients treated for skull base chordoma, chondrosarcoma, adenoid cystic carcinoma, or sinonasal malignancies between 2005 and 2012, who had at least 6 months of clinical and radiographic follow-up. The median radiation dose was 75.6 Gy (relative biological effectiveness [RBE]). Analyzed factors included gender, age, hypertension, diabetes, smoking status, use of chemotherapy, and the absolute dose:volume data for both the right and left temporal lobes, considered separately. A generalized estimating equation (GEE) regression analysis evaluated potential predictors of radiation necrosis, and the median effective concentration (EC50) model estimated dose–volume parameters associated with radiation necrosis. Results: Median follow-up time was 31 months (range 6-96 months) and was 34 months in patients who were alive. The Kaplan-Meier estimate of overall survival at 3 years was 84.9%. The 3-year estimate of any grade temporal lobe radiation necrosis was 12.4%, and for grade 2 or higher radiation necrosis was 5.7%. On multivariate GEE, only dose–volume relationships were associated with the risk of radiation necrosis. In the EC50 model, all dose levels from 10 to 70 Gy (RBE) were highly correlated with radiation necrosis, with a 15% 3-year risk of any-grade temporal lobe radiation necrosis when the absolute volume of a temporal lobe receiving 60 Gy (RBE) (aV60) exceeded 5.5 cm{sup 3}, or aV70 > 1.7 cm{sup 3}. Conclusions: Dose–volume parameters are highly correlated with the risk of developing temporal lobe radiation necrosis. In this study the risk of radiation necrosis increased sharply when the temporal lobe aV60 exceeded 5.5 cm{sup 3} or aV70 > 1.7 cm{sup 3}. Treatment planning goals should include constraints on the volume of temporal lobes receiving higher dose. The EC50 model provides suggested dose–volume temporal lobe constraints for conventionally fractionated high-dose skull base radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extreme radiation emission regime for electron beams in strong focusing ion channels and undulators

A fundamental comparison between a magnetic undulator and an ion channel, or betatron, radiation from relativistic electrons is presented. While conventional theories nominally range from the undulator (𝐾 <1) to the wiggler (𝐾 >1) regime, they are only applicable for sufficiently large Lorentz factors (𝛾 0 ≫𝐾). They therefore do not account for high 𝐾/𝛾 0 cases, for which we show that particle trajectories and radiation characteristics strongly deviate from the linear predictions in both magnetic undulators and ion channels. This problem arises from the fundamental differences between a magnetostatically and electrostatically induced oscillation. A reformulation of both the ion channel betatron wavelength and amplitude, as well as the same parameters in a magnetic undulator, permits us to compare cases with equivalent oscillation period and amplitude in the two different scenarios. The notable differences in spectral features of the two radiation mechanisms can then be addressed via numerical simulations of single particle as well as full beam dynamics. Additionally, we identify and quantify a novel transverse orbit precession effect in ion channels for particles with initial angular momentum relative to the device axis. This effect, which is significant in cases of strong transverse kinetic energy oscillations, alters both the radiation divergence and the beam emittance. In this paper, we present this new theoretical framework and compare its results with numerical simulation applied to realizable experimental tests of such radiation sources.

Frazzitta, Andrea [University of Rome “La Sapienza↗

Microstrip reflectarray antenna for the SCANSCAT radar application

This publication presents an antenna system that has been proposed as one of the candidates for the SCANSCAT (Scanned Scatterometer) radar application. It is the mechanically steered planar microstrip reflectarray. Due to its thin, lightweight structure, the antenna's mechanical rotation will impose minimum angular momentum for the spacecraft. Since no power-dividing circuitry is needed for its many radiating microstrip patches, this electrically large array antenna demonstrates excellent power efficiency. In addition, this fairly new antenna concept can provide many significant advantages over a conventional parabolic reflector. The basic formulation for the radiation fields of the microstrip reflectarray is presented. This formulation is based on the array theory augmented by the Uniform Geometrical Theory of Diffraction (UTD). A computer code for analyzing the microstrip reflectarray's performances, such as far-field patterns, efficiency, etc., is also listed in this report. It is proposed here that a breadboard unit of this microstrip reflectarray should be constructed and tested in the future to validate the calculated performance. The antenna concept presented here can also be applied in many other types of radars where a large array antenna is needed.

Huang, John↗

Evidence of trap-assisted Auger recombination in low radiative efficiency MBE-grown III-nitride LEDs

By studying low radiative efficiency blue III-nitride light emitting diodes (LEDs), we find that the ABC model of recombination commonly used for understanding efficiency behavior in LEDs is insufficient and that additional effects should be taken into account. We propose a modification to the standard recombination model by incorporating a bimolecular nonradiative term. The modified model is shown to be in much better agreement with the radiative efficiency data and to be more consistent than the conventional model with very short carrier lifetimes measured by time-resolved photoluminescence in similar, low radiative efficiency material. Here, we present experimental evidence that a hot carrier-generating process is occurring within these devices, in the form of measurements of forward photocurrent under forward bias. The forward photocurrent, due to hot carrier generation in the active region, is present despite the lack of any "efficiency droop"-the usual signature of band-to-band Auger recombination in high-quality III-nitride LEDs. Hot carrier generation in the absence of band-to-band Auger recombination implies that some other source of hot carriers exists within these low radiative efficiency devices, such as trap-assisted Auger recombination.

36 MATERIALS SCIENCE↗

Thermal engineering of FAPbI 3 perovskite material via radiative thermal annealing and in situ XRD

Lead halide perovskites have emerged as successful optoelectronic materials with high photovoltaic power conversion efficiencies and low material cost. However, substantial challenges remain in the scalability, stability and fundamental understanding of the materials. Here we present the application of radiative thermal annealing, an easily scalable processing method for synthesizing formamidinium lead iodide (FAPbI 3 ) perovskite solar absorbers. Devices fabricated from films formed via radiative thermal annealing have equivalent efficiencies to those annealed using a conventional hotplate. By coupling results from in situ X-ray diffraction using a radiative thermal annealing system with device performances, we mapped the processing phase space of FAPbI 3 and corresponding device efficiencies. Our map of processing-structure-performance space suggests the commonly used FAPbI 3 annealing time, 10 min at 170 degrees C, can be significantly reduced to 40 s at 170 degrees C without affecting the photovoltaic performance. Lastly, the Johnson-Mehl-Avrami model was used to determine the activation energy for decomposition of FAPbI 3 into PbI 2 .

14 SOLAR ENERGY↗

Improving the radiation hardness of graphene field effect transistors

Ionizing radiation poses a significant challenge to the operation and reliability of conventional silicon-based devices. In this paper, we report the effects of gamma radiation on graphene field-effect transistors (GFETs), along with a method to mitigate those effects by developing a radiation-hardened version of our back-gated GFETs. We demonstrate that activated atmospheric oxygen from the gamma ray interaction with air damages the semiconductor device, and damage to the substrate contributes additional threshold voltage instability. Our radiation-hardened devices, which have protection against these two effects, exhibit minimal performance degradation, improved stability, and significantly reduced hysteresis after prolonged gamma radiation exposure. Finally, we believe this work provides an insight into graphene's interactions with ionizing radiation that could enable future graphene-based electronic devices to be used for space, military, and other radiation-sensitive applications.

36 MATERIALS SCIENCE↗

In-situ X-Ray Analysis of Rapid Thermal Processing for Thin-Film Solar Cells: Closing the Gap between Production and Laboratory Efficiency

For materials synthesis, it is well known that the material final state may not reach equilibrium and depends on the synthetic process. In particular, processes that quickly remove the available energy from the material may leave it in a metastable state and the metastability may actually impart desirable functional properties. By its very nature, Rapid thermal processing (RTP) is ideally suited to produce such metastable materials. However, metastability and the dynamics of reaching a metastable state are poorly understood, since this is best accomplished through in situ monitoring. In this regard, RTP is particularly challenging as the processing time are very short (seconds to minutes). As a result, there is only poor understanding, and hence use, of RTP in industry. This is potentially a cost-increasing limitation, because RTP can decrease cost by decreasing processing time, and as such, increase throughput and decrease the total thermal budget of processing - a significant cost. RTP is already being used for key processing steps in PV technologies. With silicon wafer PV, it is used for establishing electrical contact between the Ag metal grid and the silicon (known as firing). In this process, a silicon wafer with deposited metal/frit in a grid pattern is heated rapidly to temperatures between 750 and 800 ºC. The processing time when the temperature is held above 600ºC is short (<5 seconds). This process has historically been optimized empirically and it is unclear how the thermal processing affects formation of the final contact between the metal and the silicon. In the case of thin-film PV, RTP has been demonstrated in the process of making absorber layers, i.e. CIGS and CZTS. Use of RTP can reduce the processing time from 10s of minutes to seconds, reducing the thermal budget and increasing the throughput significantly. The conversion from precursor material to final PV material is not well understood, and most of the process optimization is done empirically. Again, the proposed in situ monitoring will provide insight into the conversion process. We have developed a unique instrument for in situ monitoring of the reaction process during RTP. The most fundamental property to monitor is the atomic arrangement (for solids, crystalline structure) and thus we have focused on this property. The chamber was designed to collect X-ray diffraction (XRD) for crystal phase determination, although it has lent insight in the formation of liquids. We designed and constructed both inert (air) and reactive (S/Se) versions of this chamber. We have applied the RTP-XRD methodology to: silicon solar cell electrical contact formation; the reaction sequence for forming CIGS PV thin films from copper selenide and indium gallium selenide precursors; the phase sequence for forming HC(NH2)2PbI3 (FAPbI3) and CH3NH3PbI3 (MAPbI3) hybrid-perovskite PV thin films. The RTP instrument enables real-time collection of X-ray diffraction data with intervals as short as 100 ms, and while heating at ramp rates as high 100 ºCs-1 up to 1200 ºC. The system is portable and can be installed on a synchrotron beamline. The RTP reactor consists of a metallic body (front cap assembly, central block and end cap assembly) that houses a quartz reaction chamber. The sample is secured inside the reaction chamber on a sample holder connected to the front-cap assembly. Modifications of the chamber were made for safely handling sulfur and selenium vapor environments. A Se/S source holder was added to generate a Se/S over pressure in the chamber on heating and the entrance window is made wider in order to accommodate the detachable additional holder. Se/S are toxic in nature and therefore a proper Se/S trapping is used before releasing the gases to exhaust. Screen-printing provides an economically attractive means for making Ag electrical contacts to Si solar cells, but the use of Ag substantiates a significant manufacturing cost, and the glass frit used in the paste to enable contact formation contains Pb. To achieve optimal electrical performance and to develop pastes with alternative, abundant, and non-toxic materials requires understanding the contact formation process during firing. We use the RTP-XRD chamber during firing of Ag-Si contacts to reveal the reaction sequence for contact formation. The findings show that between 500 ºC and 650 ºC PbO in the frit etches the SiNx antireflective-coating on the solar cell, exposing the Si surface. Then, above 650 ºC, Ag+ dissolves into the molten glass frit – key for enabling deposition of metallic Ag on the emitter surface and precipitation of Ag nanocrystals within the glass. This clarifies contact formation mechanisms and can be used to suggest approaches for development of inexpensive, nontoxic solar cell contacting pastes. We used the RTP/XRD chamber to study the formation of CuInGaS/Se (CIGS) PV films by in-situ selenization of pre-deposited metal stacks and annealing of pre-deposited Cu-In-Ga-Se precursors. During the metal stack selenization, we observed that Se first reacts with the metals and forms selenides. We observed formation of intermetallics such as Cu2In and binary selenides during heating. On further annealing in a Se atmosphere, CuInSe2 and CuGaSe2 forms which on heating up to 550 °C reacts further to form the CIGS phase. On prolonged exposure to 550 °C for more than 5 mins or higher temperature, we see separation into Ga-rich and Ga-depleted CIGS phases. On introducing a holding step at 400 °C for 10 min during the annealing ramp, the CIGS phase (forms between 500-550 °C), appears to be less prone to decomposition into high-Ga and low-Ga phases during holding at peak temperature. Lead halide perovskites have emerged as successful optoelectronic materials with high photovoltaic power conversion efficiencies and low material cost. However, substantial challenges remain in the scalability, stability and fundamental understanding of the materials. We demonstrated the application of radiative thermal annealing, an easily scalable processing method, for synthesizing formamidinium lead iodide (FAPbI3) perovskite solar absorbers. Devices fabricated from films formed via radiative thermal annealing have equivalent efficiencies to those annealed using a conventional hotplate. By coupling results from in situ x-ray diffraction using a radiative thermal annealing system with device performances, we mapped the processing phase space of FAPbI3 and corresponding device efficiencies. Our map of processing-structure-performance space suggests the commonly used FAPbI3 annealing time, 10 min at 170 °C, can be significantly reduced to 40 s at 170 °C without affecting the photovoltaic performance. Applying the Johnson-Mehl-Avrami model to the decomposition into PbI2, the activation energy was determined. We also presented a well-controlled, manufacturing relevant annealing method, radiative thermal annealing, for the methylammonium lead triiodide films formed by solvent engineering process, with dimethylformamide (DMF) and dimethyl sulfoxide as solvent and diethyl ether as the antisolvent. Radiative thermal annealing can produce high quality perovskite films, evidenced by high efficiency solar cell devices, in a shorter time than the widely-used hotplate annealing. Using in-situ x-ray diffraction during the radiative annealing, we show that the role of the antisolvent is not to form an intermediate compound (a methylammonium iodide, lead iodide, and dimethyl sulfoxide compound) by washing of the main solvent (DMF) but to achieve a pin-hole free, uniform film of methylammonium lead iodide. We find that having the intermediate compound does not guarantee a high quality (pin-hole free) perovskite film. Our study was extended to reveal the effect of annealing environment, annealing temperature profile, and deposition substrate.

36 MATERIALS SCIENCE↗

Internal Roof and Attic Thermal Radiation Control Retrofit Strategies for Cooling-Dominated Climates

This project evaluates the cooling energy savings and cost effectiveness of radiation control retrofit strategies for residential attics in U.S. cooling-dominated climates. Usually, in residential applications, radiation control retrofit strategies are applied below the roof deck or on top of the attic floor insulation. They offer an alternative option to the addition of conventional bulkinsulation such as fiberglass or cellulose insulation. Radiation control is a potentially low-cost energy efficiency retrofit strategy that does not require significant changes to existing homes. In this project, two groups of low-cost radiation control strategies were evaluated for southern U.S. applications. One uses a radiant barrier composed of two aluminum foils combined with an enclosedreflective air space and the second uses spray-applied interior radiation control coatings (IRCC).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiation instability of equal channel angular extruded T91 at ultra-high damage levels

Although several studies have shown that nano-grained alloys have higher radiation resistance than coarse-grained variants, with dense grain boundary structures acting as defect sinks to remove damage, the present study shows the failure of severe deformation to suppress void swelling in T91 alloy at ultra-high damage levels. Fe self-ion irradiation up to 1000 peak dpa produced significantly more swelling in extruded T91 than conventional T91 at 475 °C. Dramatic radiation-enhanced grain growth was observed in the extruded T91, manifested in two rapid grain growth stages. One stage occurs at a relatively low damage level, and the other at a higher damage level beyond 750 peak dpa. The second rapid growth stage is correlated with void swelling and starts at the end of the swelling incubation period. The study suggests that the defect sink properties of the growing grain boundaries under a coarsening process are different from that of stable boundary configurations. When void swelling becomes significant and voids act as a biased sink for vacancies, the growing grain boundaries act as a biased sink for interstitials, leading to rapid growth at higher damage levels.

36 MATERIALS SCIENCE↗

SU-E-J-93: Development of Pre-Contoured Human Model Library in DICOM-RT Format for the Epidemiological Study of the Radiotherapy Patients

Purpose: Prior to 3D conformal radiation therapy planning, patient anatomy information was mostly limited to 2D beams-eye-view from the conventional simulator. To analyze the outcomes of such treatments for radiation late effects, 3D computational human models are often used in commercial treatment planning systems (TPSs). However, several underlying difficulties such as time-consuming manual delineation procedures of a large number of structures in the model have always limited its applications. Primary objective of this work was to develop a human model library for the epidemiological study by converting 3D-surface model organs to DICOM-RT format (DICOM-RT structure) using an in-house built software. We converted the ICRP reference human models to DICOM-RT models, which can be readily adopted for various dose calculations. Methods: MATLAB based code were utilized to convert the contour drawings extracted in text-format from the 3D graphic-tool, Rhinoceros into DICOM-RT structure format for 50 different organs of each model using a 16GB dual-core processor. The conversion periods were measured for each DICOM-RT models, and the reconstructed structure volumes were validated against the original 3D-surface models in the TPS. Ten reference hybrid whole-body models (8-pediatric and 2-adults) were automatically processed to create DICOM-RT computational human model library. Results: Mean contour conversion period was found to be 580 (N=2) and 394.5 (N=8) seconds for 50 organs in the adult and pediatric models respectively. A good agreement for large organs (NRMSD <1.0%) and small organs (NRMSD <7.7%) was also observed between the original volumes and corresponding DICOM-RT structure volumes of the organs. Conclusion: The ICRP reference human models were converted into DICOM-RT format to support the epidemiological study using a large cohort of conventional radiotherapy patients. Due to its DICOM-compatibility, the library may be implemented to many other different applications. We also expect to develop the library by including additional models in future.

60 APPLIED LIFE SCIENCES↗

Dosimetric evaluation of integrated IMRT treatment of the chest wall and supraclavicular region for breast cancer after modified radical mastectomy

To investigate the dosimetric characteristics of irradiation of the chest wall and supraclavicular region as an integrated volume with intensity-modulated radiation therapy (IMRT) after modified radical mastectomy. This study included 246 patients who received modified radical mastectomy. The patients were scanned with computed tomography, and the chest wall (with or without the internal mammary lymph nodes) and supraclavicular region were delineated. For 143 patients, the chest wall and supraclavicular region were combined as an integrated planning volume and treated with IMRT. For 103 patients, conventional treatments were employed with 2 tangential fields for the chest wall, abutting a mixed field of 6-MV x-rays (16 Gy) and 9-MeV electrons (34 Gy) for the upper supraclavicular region. The common prescription dose was 50 Gy/25 Fx/5 W to 90% of the target volume. The dosimetric characteristics of the chest wall, the supraclavicular region, and normal organs were compared. For the chest wall target, compared with conventional treatments, the integrated IMRT plans lowered the maximum dose, increased the minimum dose, and resulted in better conformity and uniformity of the target volume. There was an increase in minimum, average, and 95% prescription dose for the integrated IMRT plans in the supraclavicular region, and conformity and uniformity were improved. The V{sub 30} of the ipsilateral lung and V{sub 10}, V{sub 30}, and mean dose of the heart on the integrated IMRT plans were lower than those of the conventional plans. The V{sub 5} and V{sub 10} of the ipsilateral lung and V{sub 5} of the heart were higher on the integrated IMRT plans (p < 0.05) than on conventional plans. Without an increase in the radiation dose to organs at risk, the integrated IMRT treatment plans improved the dose distribution of the supraclavicular region and showed better dose conformity and uniformity of the integrated target volume of the chest wall and supraclavicular region.

61 RADIATION PROTECTION AND DOSIMETRY↗

Identifying Neutron Irradiation in Space to Mitigate Bio-Medical Effects

One of the primary challenges to interplanetary human travel is mitigation of radiation expo-sure. As fast transit with LENR driven or conventional nuclear electric (NEP) or thermal propulsion (NTP) may be imminent, time and level of radiation exposure composingALARA (As Low as Rea-sonably Achievable) must be ascertained rapidly and precisely. Since acute physiological effects are difficult to detect, and chronic effects on crew health are delayed and potentially trans-generational, improved detection technologies will be game-changing and an essential element of the crew health monitoring and environmental protection toolkit.Secondary Galactic Cosmic Ray (GCR) induced neutrons are an additional hazard.

space medicine↗

Possible mitigation of tokamak plasma–surface interactions using thermionic divertor plates with inverse sheaths

Recent studies demonstrate that when a plasma-facing surface emits a sufficient flux of electrons, it will form an inverse sheath. In this work, we consider a possibility of using thermionic target plates with inverse sheaths as an innovative divertor operating scenario. We derive an electron heat flux boundary condition for inverse sheaths and show that for given power exhaust into a tokamak scrape-off-layer, an inverse sheath leads to a much lower target plasma electron temperature than a conventional sheath. Low enough target plasma temperatures for radiative divertor detachment could therefore be achieved using inverse sheaths instead of the usual need to inject neutral atoms that compromise the core plasma. Other advantages of inverse sheath detachment over conventional sheath operating scenarios include (a) ion impact energies are as low as possible, minimizing sputtering and tritium implantation, (b) surface recombination heat flux is reduced due to ion flux reduction, and (c) arcs are inhibited due to the sign of the surface electric field. This paper outlines the basic properties of inverse sheath detachment and considers the feasibility of implementation. We offer recommendations for future modeling efforts needed to better understand the effects of thermionic emission in tokamaks and whether inverse sheaths present a viable divertor solution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved Finite-Volume Method for Radiative Hydrodynamics

Fully coupled simulations of hydrodynamics and radiative transfer are essential to a number of fields ranging from astrophysics to engineering applications. Of particular interest in this work are hypersonic atmospheric entries and associated experimental apparatus, e.g., shock tubes and high enthalpy testing facilities. The radiative transfer calculations must supply to the CFD a heating term in the energy equation in the form of the divergence of the radiative heat flux and the radiative heat fluxes to bounding surfaces. It is most efficient to solve the radiative transfer equation on the same grid as the CFD solution, and this work presents an algorithm with improved accuracy for such simulations on structured and unstructured grids compared to more conventional approaches. Results will be shown for shock radiation during hypersonic reentry. Issues of parallelization within a radiation sweep will also be discussed.

Wray, Alan↗

X-ray free-electron lasing in a flying-focus undulator

Laser-driven free-electron lasers (LDFELs) replace magnetostatic undulators with the electromagnetic fields of a laser pulse. Because the undulator period is half the wavelength of the laser pulse, LDFELs can amplify X rays using lower electron energies and over shorter interaction lengths than a traditional free-electron laser. In LDFELs driven by conventional laser pulses, the undulator uniformity required for high gain necessitates large laser-pulse energies. Here, we show that a flying-focus pulse provides the undulator uniformity required to reach high gain with a substantially lower energy than a conventional pulse. The flying-focus pulse features an intensity peak that travels in the opposite direction of its phase fronts. This enables an LDFEL configuration where an electron beam collides head-on with the phase fronts and experiences a near-constant undulator strength as it co-propagates with the intensity peak. Three-dimensional simulations of this configuration demonstrate the generation of megawatts of coherent X-ray radiation with 20 × less energy than a conventional laser pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-810: Volumetric Modulated Arc Therapy and Conventional Intensity-Modulated Radiotherapy for Non-Small-Cell Lung Cancer with Simultaneously Integrated Boost Radiation Therapy: A Planning Comparison Study

Purpose: To compare and analyze the characteristics of intensity-modulated arc therapy(IMAT) versus fixed-gantry intensity-modulated radiotherapy(IMRT) in treatment of non-small-cell lung cancer. Methods: Twelve patients treated in our radiotherapy center were selected for this study. The patient subsequently underwent 4D-CT simulation.Margins of 5mm and 10mm were added to the ITV to generate the CTV and PTV respectively. Three treatment plans (IMRT,one single arc (RA1),double arcs (RA2))were generated with Eclipse ver.8.6 planning systems. Using a dose level of 75Gy in 15fractions to the ITV,60Gy in 15fractions to the CTV and 45Gy in 15fractions to the PTV respectively. The target and normol tissue volumes were compared,as were the dosimetry parameters. Results: There were no significant differences in CI of ITV,PTV,HI of ITV,CTV and PTV, V5,V10,V15,V20,V25,V30,V45,V50 of total-lung and mean lung dose (all p>0.05). However, the differences were significant in terms of CI of CTV,V5 of B-P (all p<0.05). On the MU, IMRT=1540MU,RA1=1006 MU and RA2=1096 MU. (F=12.00,P=0.000).On the treatment time, IMRT= 13.5min,RA1= 1.5min,and RA2=2.5 min (F= 30.11,P=0.000 ). Conclusion: IMAT is equal to IMRT in dosimetril evaluation. Due to much less Mu and delivery time,IMAT is an ideal technique in treating patients by reduceing the uncomfortable influnce which could effect the treatment.

60 APPLIED LIFE SCIENCES↗

Protective, Sacrificial Coats On Optical Surfaces

Clear, easily cleaned sacrificial coats of polytetrafluoroethylene, polyurethane, silicone, or other low-outgassing organic films help maintain optical properties of surfaces of radiators, solar panels, and other components. Contamination removed by erosion of coats. Applied by conventional spraying or other techniques. Originally coats intended to protect surfaces of radiators on spacecraft in low orbit around the Earth. On Earth, used to protect optical surfaces against damage during manufacture or protect and facilitate cleaning of optical surfaces particularly delicate or otherwise not cleaned easily.

Babel, Henry W.↗

Nuclear Thermal Propulsion Development Risks

There are clear advantages of development of a Nuclear Thermal Propulsion (NTP) for a crewed mission to Mars. NTP for in-space propulsion enables more ambitious space missions by providing high thrust at high specific impulse ((is) approximately 900 sec) that is 2 times the best theoretical performance possible for chemical rockets. Missions can be optimized for maximum payload capability to take more payload with reduced total mass to orbit; saving cost on reduction of the number of launch vehicles needed. Or missions can be optimized to minimize trip time significantly to reduce the deep space radiation exposure to the crew. NTR propulsion technology is a game changer for space exploration to Mars and beyond. However, 'NUCLEAR' is a word that is feared and vilified by some groups and the hostility towards development of any nuclear systems can meet great opposition by the public as well as from national leaders and people in authority. The public often associates the 'nuclear' word with weapons of mass destruction. The development NTP is at risk due to unwarranted public fears and clear honest communication of nuclear safety will be critical to the success of the development of the NTP technology. Reducing cost to NTP development is critical to its acceptance and funding. In the past, highly inflated cost estimates of a full-scale development nuclear engine due to Category I nuclear security requirements and costly regulatory requirements have put the NTP technology as a low priority. Innovative approaches utilizing low enriched uranium (LEU). Even though NTP can be a small source of radiation to the crew, NTP can facilitate significant reduction of crew exposure to solar and cosmic radiation by reducing trip times by 3-4 months. Current Human Mars Mission (HMM) trajectories with conventional propulsion systems and fuel-efficient transfer orbits exceed astronaut radiation exposure limits. Utilizing extra propellant from one additional SLS launch and available energy in the NTP fuel, HMM radiation exposure can be reduced significantly.

Kim, Tony↗