Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computational Load Balancing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

479 records · Page 27

Multiphysics Modeling of Microreactors with NEAMS codes, and Validation Based on KRUSTY Reactivity Insertion

The NEAMS Multiphysics Applications team continues to assess code usability and functionality for microreactor design and safety analyses, while demonstrating that NEAMS tools capture both steady-state and transient behavior across distinct microreactor concepts. In FY2025, the team advanced full-core, high-fidelity, multiphysics models that solve more complex problems and strengthen verification/validation for several microreactor systems: heat-pipe microreactor (HPMR), gas-cooled microreactor (GCMR), and the KRUSTY experiment. These models employ the MOOSE MultiApp/Transfers architecture with Griffin for neutronics, BISON for heat conduction/thermomechanics, Sockeye for heat pipes, SAM/THM for coolant channels and loops, and SWIFT for hydride behavior, with meshes generated via the MOOSE Reactor Module. The graphite models available in the Grizzly code were also investigated for future analyses. For the HPMR, a Na-HPMR variant was constructed to align with recently validated heat-pipe experiments and Sockeye’s LCVF capability, enabling mechanistic heat-pipe transients and startup modeling. The Na-HPMR will serve as the primary model for HPMR investigations in upcoming tasks. The load-following and single heat-pipe failure scenarios (Griffin/BISON/Sockeye), which were previously modeled for the K-HPMR, were replicated for the Na-HPMR, showing strong negative temperature feedback and highly localized thermal effects, respectively, while the startup case captured vapor-front progression and heat-removal activation. Solid mechanics was added to the previously built K-HPMR full-core model in BISON, showing minimal impact on steady-state reactivity yet enabling stress-field predictions that prepare the path for full-core TRISO performance analyses. For the GCMR, automated steady-state and four transient scenarios were executed using Griffin/BISON/SAM/SWIFT. Results confirm robust inherent safety: power collapses promptly in loss-of-cooling events, the inlet-temperature drop settles to a new equilibrium, and a single-channel blockage yields only a ~30 K local fuel-temperature rise with <0.4% power decrease. SWIFT-predicted hydrogen redistribution affects reactivity during both steady-state and transient conditions, underscoring its importance. A Brayton-cycle balance of plant (BOP) model in SAM/THM demonstrated stable startup behavior, and xenon-driven reactivity during load following was analyzed. To improve TRISO-compact temperature fidelity, a fast multiscale Heat Source Decomposition (HSD) treatment was implemented. Against heterogeneous benchmarks, HSD reduces underprediction of kernel temperatures and lowers predicted peak powers in reactivity-insertion transients compared to previous homogenized models. KRUSTY warm-critical validation progressed from FY2024 baselines: the 15Ȼ insertion shows excellent agreement in peak power (~2% high) and temperature trends, and the 30Ȼ case was automated via a feedback controller that maintained power near 3 kW for ~150 s with close agreement to data. The successful modeling of the warm critical tests has laid a strong foundation for simulating more complex nuclear system tests in the years ahead. Throughout FY2025, developer feedback was provided (e.g., MOOSE batch mesh generation, distributed pre-split meshes, Griffin sweeper on displaced meshes), several new models were contributed to the Virtual Test Bed, and an OECD-NEA WPRS multiphysics benchmark based on the HPMR was initiated to enable broader cross-comparison and best-practice development with the nuclear community at large.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

Calcium Phosphate Constraints in HLW Glasses: Phosphate Liquidus Model

About 50 million gallons of high-level mixed waste is currently stored in underground tanks at the United States Department of Energy’s (DOE’s) Hanford site in the State of Washington. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) will provide DOE’s Office of River Protection (ORP) with a means of treating this waste by vitrification for subsequent disposal. The tank waste will be separated into low- and high-activity waste fractions, which will then be vitrified respectively into Immobilized Low Activity Waste (ILAW) and Immobilized High Level Waste (IHLW) products. The ILAW product will be disposed in an engineered facility on the Hanford site while the IHLW product is designed for acceptance into a national geological disposal facility for high-level nuclear waste. The ILAW and IHLW products must meet a variety of requirements before they can be accepted for disposal. Glass property-composition models will be used to control the vitrification process at the WTP to ensure that the glass meets product quality and processability requirements. The quality and the validity ranges of the property-composition models and the supporting database will greatly influence waste treatment operations, including the waste loading that is achievable in the glass for each waste composition. The current baseline models for operation of the WTP were developed under the Bechtel National, Inc. (BNI) WTP contract. These models were based on LAW and HLW glass property data over a range of compositions that was guided primarily by the WTP contract and the set of tanks specified therein. The HLW testing was directed towards waste streams from the then-planned early feed tanks for the WTP (i.e., AZ-101, AZ-102, C-106/AY-102, and C-104/AY-101). These wastes are high in iron (AZ-101, AZ-102, and C-106/AY-102) or thorium (C-104/AY-101). While the baseline models may be adequate for commissioning of the facility and processing of the specified tanks, refinements and extensions or augmentations of these models will be required to process the balance of the tank waste inventory. The overall mission of the WTP will require the immobilization of tank waste compositions that are variously dominated by mixtures of aluminum, chromium, bismuth, iron, phosphorous, zirconium, and sulfur compounds as waste-loading-limiting components. Further, the WTP contract includes minimum waste loading requirements that are generally rather modest while loadings significantly higher than those in the current baseline are likely achievable. In order to achieve these higher waste loadings and to expand the applicable composition regions, new models will be needed to support the optimized operation of the WTP. Since the development of the baseline WTP models, ORP directed a program of work at the Vitreous State Laboratory (VSL) to examine various approaches for optimization of the performance of the WTP, including increasing the waste loadings in the LAW and HLW glass products. That work involved HLW rich in Al, Al+Na, Cr, Bi, S, Zr, Sr, P and Fe, in contrast to old baseline models that were based mostly on HLW tanks that were high in Fe, with one other that was also high in Th. Glass property data collected under the ORP program were compiled and combined with data collected to develop the WTP models. The combined databases have been used to update pre-existing HLW composition models or to develop new models for properties such as Product Consistency Test (PCT) responses, spinel crystallization (one-percent crystal fraction temperature, T 1% ), melt viscosity, melt electrical conductivity, nepheline formation upon slow cooling (i.e., Canister Centerline Cooling [CCC]), and Toxicity Characteristic Leach Procedure (TCLP) Cd response. While spinel is typically the most commonly occurring phase in HLW glasses, other phases can be limiting depending on the waste and glass composition. For example, various phosphate phases can become important as the phosphorus content increases. Lithium phosphate crystallization can impact PCT releases of HLW glasses, while calcium phosphate phases forming in the cold-cap can deleteriously impact feed processing in the melter. At present, however, no models exist that relate glass composition and crystallization of phosphate phases in general and calcium phosphate in particular. The present work was therefore directed towards the initial development of such models. Future work may be directed at studying amorphous phase separation in high phosphate HLW glasses. Within the River Protection Project, feed compositions are projected using the Hanford Tank Waste Operations Simulator (HTWOS), a dynamic computer model that tracks the waste through storage, retrieval, feed staging, and treatment processes. A review of the HTWOS data shows that WTP will process 4106 batches of HLW glass for the overall mission (System Plan Rev. 6, ORP-11242), each with its own waste feed and glass composition. Some of the projected HTWOS feed batches are expected to have relatively high concentrations of phosphorous compared to typical HLW streams. In the 4106 batches of HLW for the overall WTP mission P 2 O 5 varies from 0.59 wt% to 13.00 wt%, with 95 batches containing at least 10 wt% P 2 O 5 . Occurrences of phosphate crystals have commonly been noted in glasses with high bismuth and phosphorus contents. In addition, recently collected data from a set of statistically designed HLW matrix glasses prepared and characterized to support enhancement of the HLW glass property-composition models identified apatite in a number of glass samples. However, the current HLW model for crystallization (one-percent crystal fraction temperature) is applicable only to spinel crystallization in glasses. Previous projections of waste loadings and glass volume (such as those in System Plan Rev. 6, ORP-11242) have used preliminary constraints for calcium phosphate crystallization that are based on the limited available data. Additional data and improved constraints or, preferably, models that relate glass composition to crystallization of phosphate-containing phases, are therefore needed to support HLW vitrification at the WTP. The present study focuses on the development of such a model based on data from previously characterized glasses and a set of newly fabricated glasses.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An overlapping Domain Decomposition preconditioning method for monolithic solution of shear bands

Metals subjected to high strain rate impact often exhibit a sudden and profound drop in the material’s load bearing capability, a ductile failure phenomenon known as shear banding. Shear bands, characterized as material instabilities, are driven by shear heating and described as narrow regions that have sustained intense plastic deformation and high temperature rise. This coupled thermo-mechanical localization problem can be formulated as a nonlinear system with two balance equations, momentum and energy, and two constitutive laws for elasticity and plasticity. Here in our formulation, mixed finite elements are used to discretize the equations in space and an implicit finite difference scheme is used to advance the system in time, where at every time step, a Newton type method is used to solve the system monolithically. To that end, a block Jacobian matrix is formed analytically using Gâteaux derivatives. The resulting Jacobian is sparse, nonsymmetric and its sparsity pattern and eigenvalue content vary with the different stages of shear bands formation, consequently posing a significant challenge to iterative solvers. To address this issue, an overlapping Domain Decomposition preconditioner that takes into account the physics of shear bands and the domain in which it forms, is proposed. The key idea is to resolve the shear band domain accurately while only solving the remaining domain approximately, with selective updates when necessary. The preconditioner is formed on the basis of an additive Schwartz method that is applied to a Schur complement partition of the system. The proposed preconditioner is implemented in parallel and tested on three different benchmark problems as compared against off-the-shelf solvers. We study the effect of h- and k-refinement that are obtained from Isogeometric discretizations of the system, the overlapping strategy and its parallel performance. Excellent performance is demonstrated in serial and parallel on all benchmark examples.

42 ENGINEERING↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis – Simulated Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wind turbine. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen . While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the simulated wind energy profiles, NLR used OpenFAST to simulate a 3.4-MW International Energy Agency (IEA) reference wind turbine. The hour-long wind energy profiles varied over wind turbulence intensity (Class A or Class C) and average wind speed (5, 7, or 9 m/s). To match the power limits of the 1.25-MW electrolyzer and 3.4-MW IEA wind turbine most effectively and to maximize the efficiency of hydrogen production at a given average wind speed, the profiles were sometimes scaled by two times. This means that, in some cases, the experimental setup assumed two 1.25-MW electrolyzers were coupled with the wind turbine, representing a total maximum electrolysis load of 2.5 MW. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}-{average wind speed}-{turbulence class}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “windIEA3.4-5ms-C_2-400.zip” represents the hour-long experiment using the IEA 3.4-MW turbine, subjected to an average wind speed of 5 m/s and Class C wind turbulence, and connected to two 1.25-MW electrolyzers with the power supply set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wind turbine power. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis .

08 HYDROGEN↗

Grid-Integrated Production of Fischer-Tropsch Synfuels from Nuclear Power

Idaho National Laboratory (INL) investigates the relative economic profitability of an integrated energy system (IES) coupling an NPP with a synfuel production process at selected case study locations across the United States. In the synfuel IES, a high-temperature steam electrolysis (HTSE) plant is thermally and electrically coupled with an NPP to produce zero-carbon hydrogen. The synthetic fuel is produced from this H 2 combined with a CO 2 supply using the reverse water gas shift process followed by the Fischer-Tropsch (FT) reaction. This analysis considers a system in which the CO 2 is sourced from regional CO 2 emitters via the construction and operation of pipeline-based CO 2 supply networks. Locating the FT plant at the same site as the NPP and HTSE plants enables the NPP to provide zero-carbon heat and power to the HTSE plant and zero-carbon power to the FT plant as well as avoid the requirement for long-distance H 2 product transport from the HTSE plant to the FT plant. Hydrogen storage is used to enable the NPP to dispatch power to the electrical grid (instead of the HTSE plant) when grid demand increases, thus enabling the FT plant to continue to operate in a steady-state production mode. The ability to cease hydrogen production for several hours within each day enables the NPP to provide power to the grid to balance the electricity market during peak periods and maximize revenues for the nuclear synfuel IES. The FT process design considered has a 99% carbon conversion efficiency. The use of nuclear energy and nuclear energy-derived hydrogen enables synfuel production to achieve this high level of carbon utilization. Additionally, the life-cycle carbon emissions of the nuclear-based synfuel production process are very low, with WTW emissions of approximately 25 gCO 2 e/MJ, including steam credits (generated from FT process excess heat), and approximately 7 gCO 2 e/MJ, if steam credits are excluded. This compares favorably with the WTW emissions of 90.5 gCO 2 e/MJ for a compression-ignition, direct injection (CIDI) vehicle with a fuel economy of 31.6 miles per gallon gasoline equivalent (MPGGE), using low-sulfur diesel produced using conventional petroleum production and refining processes. Several NPPs in various regions of the U.S. are considered as case study analyses. Supply locations and transportation via pipeline of the CO 2 feedstock to the NPP site are analyzed through the National Energy Technology Laboratory (NETL) CO 2 Transport Cost model. The team finds that the amount of CO 2 generated by different sectors is sufficient for the synfuel production process at all locations considered. The CO 2 transportation costs are functions of the distance of the source to the NPP location, the CO 2 capture cost at the source, and the quantity of CO 2 transported. Historical electricity prices for the NPP case study locations are collected and analyzed. Monthly average prices, price range, and duration of negative-price periods vary among these locations. For each location, an auto-regressive moving average (ARMA) model is trained on historical electricity price data. ARMA validation is done to ensure the synthetic price distributions represent one of historical prices with high fidelity. Synthetic time series from these ARMA models are used in a coupled dispatch and system optimization in the Holistic Energy Resource Optimization Network (HERON) to compute the differential net present value (NPV) of the IES. The team finds that this econometric is positive, ranging from $14M–1.3bn (2020) depending on the location. The optimal synfuel IES configuration to obtain this increase in NPV often maximizes the size of the synfuel production process with regards to the size of the NPP. However, the team shows that the NPP still plays a stabilizing role for the grid: In periods of high prices and high loads, more electricity from the NPP is sent to the grid. A high variability of electricity prices and extreme maximum prices tend to drive up electricity production. While it requires significant investment, the synfuel IES could increase the economic profitability for the existing fleet of LWRs across the country while still maintaining the grid stabilizer role of NPPs. During its lifetime, the main costs for the nuclear synfuel IES are the carbon feedstock transportation costs, followed by the capital expenses (CAPEX) and operation and maintenance (O&M) costs while the revenue comes first from the IRA H 2 production tax credit (PTC) and then from the sales of synfuel products. The profitability of the synfuel IES is most sensitive to the value of the hydrogen PTC and the synfuel products as well as the cost of the carbon feedstock, highlighting the importance of governmental incentives regarding hydrogen, carbon emissions, and synfuel in driving the deployment of future nuclear synfuel IESs.

08 HYDROGEN↗

Experimental Design for Hanford Low-Activity Waste Glasses with High Waste Loading

This report discusses the development of an experimental design for the initial phase of the Hanford low-activity waste (LAW) enhanced glass study. This report is based on a manuscript written for an applied statistics journal. Appendices A, B, and E include additional information relevant to the LAW enhanced glass experimental design that is not included in the journal manuscript. The glass composition experimental region is defined by single-component constraints (SCCs), linear multiple-component constraints (MCCs), and a nonlinear MCC involving 15 LAW glass components. Traditional methods and software for designing constrained mixture experiments with SCCs and linear MCCs are not directly applicable because of the nonlinear MCC. A modification of existing methodology to account for the nonlinear MCC was developed and is described in this report. One of the glass components, SO 3 , has a solubility limit in glass that depends on the composition of the balance of the glass. A goal was to design the experiment so that SO 3 would not exceed its predicted solubility limit for any of the experimental glasses. The SO 3 solubility limit had previously been modeled by a partial quadratic mixture model expressed in the relative proportions of the 14 other components. The partial quadratic mixture model was used to construct a nonlinear MCC in terms of all 15 components. In addition, there were SCCs and linear MCCs. This report describes how a layered design was generated to (i) account for the SCCs, linear MCCs, and nonlinear MCC and (ii) meet the goals of the study. A layered design consists of points on an outer layer, and inner layer, and a center point. There were 18 outer-layer glasses chosen using optimal experimental design software to augment 147 existing glass compositions that were within the LAW glass composition experimental region. Then 13 inner-layer glasses were chosen with the software to augment the existing and outer-layer glasses. The experimental design was completed by a center-point glass, a Vitreous State Laboratory glass, and replicates of the center point and Vitreous State Laboratory glasses.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Technical and Economic Assessment of LWR Flexible Operation for Generation and Demand Balancing to Optimize Plant Revenue

With increased penetration of subsidized variable renewable energy (VRE) resources and competition from low natural gas prices, existing light water reactor (LWR) nuclear power plants (NPPs) are struggling to remain economically competitive. This work examines the potential economic competitiveness of various thermal energy storage (TES) technologies when coupled directly or indirectly with a NPP. To highlight their relative economic competitiveness, we contrast several energy storage solutions in stochastic dispatch optimization. We leverage data from recent work analyzing a range of TES technologies with varying capital costs, performance, and technology readiness level (TRL) to establish our case. We explore inserting these technologies into an electricity market with existing nuclear generation and large projected variable renewable energy (VRE) penetration. Although these technologies' projected capital costs may make them unlikely candidates in their current state, this analysis demonstrates a high-fidelity techno-economic analysis of energy storage. Furthermore, as the projected cost of energy storage technologies evolves, this analysis sets a precedent for similar future investigations. One region with projected trends that may be unfavorable for existing nuclear capacity is the New York Independent System Operator (NYISO) market. New York state’s baseload generation has been historically provided by fossil-fired and nuclear assets. However, amid economic pressures from subsidized VREs and low natural gas prices, the state has recently deactivated Indian Point nuclear power plant units 2 and 3. Furthermore, the state plans to meet its zero-emission generation target by 2040 by replacing fossil-fired capacity with significant investments in VRE resources like wind and solar photovoltaic (PV) and battery storage. Increased intermittent resource penetration lowers the baseload power requirement, adding further economic pressure to the state’s three remaining NPPs still in operation. With three NPPs still in operation in New York, this work analyzes potential economic benefits to NPPs on the New York grid when directly or indirectly coupled with various TES technologies. This work requires two modeling steps to analyze the potential economic benefits of various system configurations of the TES directly or indirectly coupled with nuclear. First, this analysis leverages capacity expansion modeling by experts at the Electric Power Research Institute (EPRI). Using their deterministic capacity expansion model, U.S. Regional Economy, Greenhouse Gas, and Energy (US-REGEN), EPRI analysts evaluated the capacity and generation evolution of the New York state energy market under four projection scenarios. These four projection scenarios were developed to represent the potential evolution of the capacity and generation in NYISO from 2015 to 2050 under various economic, technology, and policy constraints. The results from these capacity expansion models are then used as boundary conditions in the second modeling step. The second modeling step uses the Holistic Energy Resource Optimization Network (HERON) for a set of stochastic techno-economic analyses (STEAs) to investigate the potential increase in the economic viability of various configurations of the TES. With no current capacity expansion capabilities, HERON takes the data generated from US-REGEN for 2050 to generate synthetic load, solar, and wind data. Then HERON economically optimizes the capacity and dispatch of the various TES configurations. The potential economic benefit is the differential net present value (NPV) of the TES configurations from the no-TES baseline. As a stochastic techno-economic analysis package, HERON introduces uncertainty into the economic metrics, while US-REGEN trades resolution for reduced computational complexity. Using HERON also allows the modeling of direct thermal coupling, a feature not common in capacity and dispatch models. As expected, with high capital costs, the costs of introducing energy storage for all the technologies considered outweighed the potential economic benefit of this strategy for flexible plant operation. The benefit of this analysis is primarily in demonstrating a workflow that examines innovative solutions to increase NPP revenue via TES coupling. HERON’s stochastic capacity and dispatch optimization process used in this work has proven an effective tool in observing and evaluating the impact of introducing storage technologies in a grid energy system.

25 ENERGY STORAGE↗

Modeling and optimization of a modified claus process as part of an integrted gasification combined cycle (IGCC) power plant with CO2 capture

The modified Claus process is one of the most common technologies for sulfur recovery from acid gas streams. Important design criteria for the Claus unit, when part of an Integrated Gasification Combined Cycle (IGCC) power plant, are the ability to destroy ammonia completely and recover sulfur thoroughly from a relatively low purity acid gas stream without sacrificing flame stability. Due to these criteria, modifications are often required to the conventional process, resulting in a modified Claus process. For the studies discussed here, these modifications include the use of a 95% pure oxygen stream as the oxidant, a split flow configuration, and the preheating of the feeds with the intermediate pressure steam generated in the waste heat boiler (WHB). In the future, for IGCC plants with CO2 capture, the Claus unit must satisfy emission standards without sacrificing the plant efficiency in the face of typical disturbances of an IGCC plant such as rapid change in the feed flowrates due to load-following and wide changes in the feed composition because of changes in the coal feed to the gasifier. The Claus unit should be adequately designed and efficiently operated to satisfy these objectives. Even though the Claus process has been commercialized for decades, most papers concerned with the modeling of the Claus process treat the key reactions as equilibrium reactions. Such models are validated by manipulating the temperature approach to equilibrium for a set of steady-state operating data, but are of limited use for dynamic studies. One of the objectives of this study is to develop a model that can be used for dynamic studies. In a Claus process, especially in the furnace and the WHB, many reactions may take place. In this work, a set of linearly independent reactions has been identified and kinetic models of the furnace flame and anoxic zones, WHB, and catalytic reactors have been developed. To facilitate the modeling of the Claus furnace, a four-stage method was devised so as to determine which set of linearly independent reactions would best describe the product distributions from available plant data. Various approaches are taken to derive the kinetic rate expressions which are either missing in the open literature or found to be inconsistent. A set of plant data is used for optimal estimation of the kinetic parameters. The final model agrees well with the published plant data. Using the developed kinetics models of the Claus reaction furnace, WHB, and catalytic stages, two optimization studies are carried out. The first study shows that there exists an optimal steam pressure generated in the WHB that balances hydrogen yield, oxygen demand, and power generation. In the second study, it is shown that an optimal H2S/SO2 ratio exists that balances single-pass conversion, hydrogen yield, oxygen demand, and power generation. In addition, an operability study has been carried out to examine the operating envelope in which both H2S/SO2 ratio and adiabatic flame temperature can be controlled in the face of disturbances typical for the operation of an IGCC power plant with CO2 capture. Impact of CO2 capture on the Claus process has also been discussed.

08 HYDROGEN↗

Scalability analysis of heavy-duty gas turbines using data-driven machine learning

With the increasing integration of variable renewable energy sources into power systems, the role of flexible power generation technologies like gas turbines (GT) in rapid grid balancing remains crucial. This sustained importance underscores the need for scaled and precise modeling of GT to ensure effective integration within evolving energy frameworks. While physics-driven GT models integrate thermodynamics, fluid dynamics, and combustion principles, they often rely on approximate mathematical representations to accommodate scaling that may not capture the actual complex dynamics for GTs and inertial effects associated to GTs with different ratings. In this study, a data-driven model is proposed using machine learning (ML) techniques to conduct GT scalability analysis and performance evaluation with high accuracy. The ML model, trained on data from various operating conditions and performance parameters, aims to uncover intricate relationships and patterns, resembling GT characteristics at different scales (ratings). The model is developed to capture complex system interaction and to adapt to changing operational scenarios at different capacities, providing valuable insights of power system dynamics. In this study, the real-time digital simulator platform was employed to generate training data for the ML model and assess its dynamic characteristics. The ultimate objective was to develop a detailed modeling framework based on governing equations and data-driven ML capable of predicting key performance indicators, in thermal systems such as GTs, including power output, speed, fuel consumption, and exhaust temperature under diverse operating conditions at different scales. The developed ML framework demonstrated high accuracy, with mean relative errors for GT power prediction, reference speed, exhaust temperature, and compressor pressure ratio (CPR) parameters consistently below 0.1% across typical load fluctuation scenarios. Maximum deviations were limited to approximately 0.5 K for exhaust temperature and 0.009 for CPR, underscoring the model’s ability to replicating dynamic GT behavior with high precision. The adaptability of the ML model enables its application across diverse operational conditions and its extension to other thermal systems. By leveraging advanced ML techniques, this study presents a robust and scalable modeling framework that enhances GT simulation precision, facilitating improved integration into evolving power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of the ANL Plant Dynamics Code and Control Strategies for the Supercritical Carbon Dioxide Brayton Cycle and Code Validation with Data from the Sandia Small-Scale Supercritical Carbon Dioxide Brayton Cycle Test Loop

Significant progress has been made in the ongoing development of the Argonne National Laboratory (ANL) Plant Dynamics Code (PDC), the ongoing investigation and development of control strategies, and the analysis of system transient behavior for supercritical carbon dioxide (S-CO 2 ) Brayton cycles. Several code modifications have been introduced during FY2011 to extend the range of applicability of the PDC and to improve its calculational stability and speed. A new and innovative approach was developed to couple the Plant Dynamics Code for S-CO 2 cycle calculations with SAS4A/SASSYS-1 Liquid Metal Reactor Code System calculations for the transient system level behavior on the reactor side of a Sodium-Cooled Fast Reactor (SFR) or Lead-Cooled Fast Reactor (LFR). The new code system allows use of the full capabilities of both codes such that whole-plant transients can now be simulated without additional user interaction. Several other code modifications, including the introduction of compressor surge control, a new approach for determining the solution time step for efficient computational speed, an updated treatment of S-CO 2 cycle flow mergers and splits, a modified enthalpy equation to improve the treatment of negative flow, and a revised solution of the reactor heat exchanger (RHX) equations coupling the S-CO 2 cycle to the reactor, were introduced to the PDC in FY2011. All of these modifications have improved the code computational stability and computational speed, while not significantly affecting the results of transient calculations. The improved PDC was used to continue the investigation of S-CO 2 cycle control and transient behavior. The coupled PDC-SAS4A/SASSYS-1 code capability was used to study the dynamic characteristics of a S-CO 2 cycle coupled to a SFR plant. Cycle control was investigated in terms of the ability of the cycle to respond to a linear reduction in the electrical grid demand from 100% to 0% at a rate of 5%/minute. It was determined that utilization of turbine throttling control below 50% load improves the cycle efficiency significantly. Consequently, the cycle control strategy has been updated to include turbine throttle valve control. The new control strategy still relies on inventory control in the 50%-90% load range and turbine bypass for fine and fast generator output adjustments, but it now also includes turbine throttling control in the 0%-50% load range. In an attempt to investigate the feasibility of using the S-CO 2 cycle for normal decay heat removal from the reactor, the cycle control study was extended beyond the investigation of normal load following. It was shown that such operation is possible with the extension of the inventory and the turbine throttling controls. However, the cycle operation in this range is calculated to be so inefficient that energy would need to be supplied from the electrical grid assuming that the generator could be capable of being operated in a motoring mode with an input electrical energy from the grid having a magnitude of about 20% of the nominal plant output electrical power level in order to maintain circulation of the CO 2 in the cycle. The work on investigation of cycle operation at low power level will be continued in the future. In addition to the cycle control study, the coupled PDC-SAS4A/SASSYS-1 code system was also used to simulate thermal transients in the sodium-to-CO 2 heat exchanger. Several possible conditions with the potential to introduce significant changes to the heat exchanger temperatures were identified and simulated. The conditions range from reactor scram and primary sodium pump failure or intermediate sodium pump failure on the reactor side to pipe breaks and valve malfunctions on the S-CO 2 side. It was found that the maximum possible rate of the heat exchanger wall temperature change for the particular heat exchanger design assumed is limited to ±7 C/s for less than 10 seconds. Modeling in the Plant Dynamics Code has been compared with available data from the Sandia National Laboratories (SNL) small-scale S-CO 2 Brayton cycle demonstration that is being assembled in a phased approach currently at Barber-Nichols Inc. and at SNL in the future. The available data was obtained with an earlier configuration of the S-CO 2 loop involving only a single-turbo-alternator-compressor (TAC) instead of two TACs, a single low temperature recuperator (LTR) instead of both a LTR and a high temperature recuperator (HTR), and fewer than the later to be installed full set of electric heaters. Due to the absence of the full heating capability as well as the lack of a high temperature recuperator providing additional recuperation, the temperature conditions obtained with the loop are too low for the loop conditions to be prototypical of the S-CO 2 cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗