Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computing, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Test of the Equivalence Principle in an Einstein Elevator

The scientific goal of the experiment is to test the equality of gravitational and inertial mass (i.e., to test the Principle of Equivalence) by measuring the independence of the rate of fall of bodies from their compositions. The measurement is accomplished by measuring the relative displacement (or equivalently acceleration) of two falling bodies of different materials which are the proof masses of a differential accelerometer spinning about an horizontal axis to modulate a possible violation signal. A non-zero differential acceleration appearing at the signal frequency will indicate a violation of the Equivalence Principle. The goal of the experiment is to measure the Eotvos ratio og/g (differential acceleration/common acceleration) with a targeted accuracy that is about two orders of magnitude better than the state of the art (presently at several parts in 10(exp 13). The analyses carried out during this first grant year have focused on: (1) evaluation of possible shapes for the proof masses to meet the requirements on the higher-order mass moment disturbances generated by the falling capsule; (2) dynamics of the instrument package and differential acceleration measurement in the presence of errors and imperfections; (3) computation of the inertia characteristic of the instrument package that enable a separation of the signal from the dynamics-related noise; (4) a revised thermal analysis of the instrument package in light of the new conceptual design of the cryostat; (5) the development of a dynamic and control model of the capsule attached to the gondola and balloon to define the requirements for the leveling mechanism (6) a conceptual design of the leveling mechanism that keeps the capsule aligned before release from the balloon; and (7) a new conceptual design of the customized cryostat and a preliminary valuation of its cost. The project also involves an international cooperation with the Institute of Space Physics (IFSI) in Rome, Italy. The group at IFSI is in charge of prototyping the differential accelerometer and carrying out precursor laboratory measurements. During this grant year, our partners analyzed and then designed a new prototype of differential accelerometer that has several characteristics in common with the flight accelerometer at this point of the instrument development. The highlights of these activities are documented in a section of this report.

Shapiro, Irwin I.↗

An advanced cockpit instrumentation system: The coordinated cockpit display

Cathode Ray Tube (CRT) and computer technologies are described in one approach to the replacement of flight instruments using three separate color CRT's. Each CRT display information pertinent to one of the three orthogonal projections of the aircraft flight situation. Three airline pilot's assessment of the display set is presented. Comments, rankings, and ratings show that the pilots accepted the concept of pictorial flight displays.

Baty, D. L.↗

A multi-scale cognitive interaction model of instrument operations at the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) is the world’s first x-ray free electron laser. It is a scientific user facility operated by the SLAC National Accelerator Laboratory, at Stanford, for the U.S. Department of Energy. As beam time at LCLS is extremely valuable and limited, experimental efficiency—getting the most high quality data in the least time—is critical. Our overall project employs cognitive engineering methodologies with the goal of improving experimental efficiency and increasing scientific productivity at LCLS by refining experimental interfaces and workflows, simplifying tasks, reducing errors, and improving operator safety and stress. Here, in this study, we describe a multi-agent, multi-scale computational cognitive interaction model of instrument operations at LCLS. Our model simulates the aspects of human cognition at multiple cognitive and temporal scales, ranging from seconds to hours, and among agents playing multiple roles, including instrument operator, real time data analyst, and experiment manager. The model can roughly predict impacts stemming from proposed changes to operational interfaces and workflows. Example results demonstrate the model’s potential in guiding modifications to improve operational efficiency. We discuss the implications of our effort for cognitive engineering in complex experimental settings and outline future directions for research. The model is open source, and the videos of the supplementary material provide extensive detail.

47 OTHER INSTRUMENTATION↗

Multimodality Instrument for Tissue Characterization

A system with multimodality instrument for tissue identification includes a computer-controlled motor driven heuristic probe with a multisensory tip is discussed. For neurosurgical applications, the instrument is mounted on a stereotactic frame for the probe to penetrate the brain in a precisely controlled fashion. The resistance of the brain tissue being penetrated is continually monitored by a miniaturized strain gauge attached to the probe tip. Other modality sensors may be mounted near the probe tip to provide real-time tissue characterizations and the ability to detect the proximity of blood vessels, thus eliminating errors normally associated with registration of pre-operative scans, tissue swelling, elastic tissue deformation, human judgement, etc., and rendering surgical procedures safer, more accurate, and efficient. A neural network, program adaptively learns the information on resistance and other characteristic features of normal brain tissue during the surgery and provides near real-time modeling. A fuzzy logic interface to the neural network program incorporates expert medical knowledge in the learning process. Identification of abnormal brain tissue is determined by the detection of change and comparison with previously learned models of abnormal brain tissues. The operation of the instrument is controlled through a user friendly graphical interface. Patient data is presented in a 3D stereographics display. Acoustic feedback of selected information may optionally be provided. Upon detection of the close proximity to blood vessels or abnormal brain tissue, the computer-controlled motor immediately stops probe penetration.

Mah, Robert W.↗

Theoretical computation of trace gases retrieval random error from measurements of high spectral resolution infrared sounder

The purpose of this paper is to demonstrate the trace gas profiling capabilities of future passive high spectral resolution (1 cm(exp -1) or better) infrared (600 to 2700 cm(exp -1)) satellite tropospheric sounders. These sounders, such as the grating spectrometer, Atmospheric InfRared Sounders (AIRS) (Chahine et al., 1990) and the interferometer, GOES High Resolution Interferometer Sounder (GHIS), (Smith et al., 1991) can provide these unique infrared spectra which enable us to conduct this analysis. In this calculation only the total random retrieval error component is presented. The systematic error components contributed by the forward and inverse model error are not considered (subject of further studies). The total random errors, which are composed of null space error (vertical resolution component error) and measurement error (instrument noise component error), are computed by assuming one wavenumber spectral resolution with wavenumber span from 1100 cm(exp -1) to 2300 cm(exp -1) (the band 600 cm(exp -1) to 1100 cm(exp -1) is not used since there is no major absorption of our three gases here) and measurement noise of 0.25 degree at reference temperature of 260 degree K. Temperature, water vapor, ozone and mixing ratio profiles of nitrous oxide, carbon monoxide and methane are taken from 1976 US Standard Atmosphere conditions (a FASCODE model). Covariance matrices of the gases are 'subjectively' generated by assuming 50 percent standard deviation of gaussian perturbation with respect to their US Standard model profiles. Minimum information and maximum likelihood retrieval solutions are used.

Huang, Hung-Lung↗

Spacecraft computer resource margin management

The conduction of the Project Galileo Orbiter, with 18 microcomputers and the equivalent of 360K 8-bit bytes of memory contained within two major engineering subsystems and eight science instruments, requires that the key onboard computer system resources be managed in a very rigorous manner. Attention is given to the rationale behind the project policy, the development stage, the preliminary design stage, the design/implementation stage, and the optimization or 'scrubbing' stage. The implementation of the policy is discussed, taking into account the development of the Attitude and Articulation Control Subsystem (AACS) and the Command and Data Subsystem (CDS), the reporting of margin status, and the response to allocation oversubscription.

Larman, B. T.↗

Automated Instrumentation, Monitoring and Visualization of PVM Programs Using AIMS

We present views and analysis of the execution of several PVM codes for Computational Fluid Dynamics on a network of Sparcstations, including (a) NAS Parallel benchmarks CG and MG (White, Alund and Sunderam 1993); (b) a multi-partitioning algorithm for NAS Parallel Benchmark SP (Wijngaart 1993); and (c) an overset grid flowsolver (Smith 1993). These views and analysis were obtained using our Automated Instrumentation and Monitoring System (AIMS) version 3.0, a toolkit for debugging the performance of PVM programs. We will describe the architecture, operation and application of AIMS. The AIMS toolkit contains (a) Xinstrument, which can automatically instrument various computational and communication constructs in message-passing parallel programs; (b) Monitor, a library of run-time trace-collection routines; (c) VK (Visual Kernel), an execution-animation tool with source-code clickback; and (d) Tally, a tool for statistical analysis of execution profiles. Currently, Xinstrument can handle C and Fortran77 programs using PVM 3.2.x; Monitor has been implemented and tested on Sun 4 systems running SunOS 4.1.2; and VK uses X11R5 and Motif 1.2. Data and views obtained using AIMS clearly illustrate several characteristic features of executing parallel programs on networked workstations: (a) the impact of long message latencies; (b) the impact of multiprogramming overheads and associated load imbalance; (c) cache and virtual-memory effects; and (4significant skews between workstation clocks. Interestingly, AIMS can compensate for constant skew (zero drift) by calibrating the skew between a parent and its spawned children. In addition, AIMS' skew-compensation algorithm can adjust timestamps in a way that eliminates physically impossible communications (e.g., messages going backwards in time). Our current efforts are directed toward creating new views to explain the observed performance of PVM programs. Some of the features planned for the near future include: (a) ConfigView, showing the physical topology of the virtual machine, inferred using specially formatted IP (Internet Protocol) packets; and (b) LoadView, synchronous animation of PVM-program execution and resource-utilization patterns.

Mehra, Pankaj↗

Automatic Range Changer For SWR Meter

Commercial unit modified for antenna-pattern measurements. Addition of automatic range-changing circuit converts Hewlett-Packard 415E standing-wave-ratio (SWR) meter into radio-frequency detector suitable for computer-controlled measurements of radiation patterns of antennas. Modification gives SWR meter effective dynamic range of at least 40 dB. Includes two digital lines communicating one of four range settings to controlling computer and one digital line to inhibit transfer of data when range being changed. Ideal instrument for use in applications involving computer-controlled monitoring of power when large changes in signal level expected.

Dengler, Robert J.↗

A simplified gross thrust computing technique for an afterburning turbofan engine

A simplified gross thrust computing technique extended to the F100-PW-100 afterburning turbofan engine is described. The technique uses measured total and static pressures in the engine tailpipe and ambient static pressure to compute gross thrust. Empirically evaluated calibration factors account for three-dimensional effects, the effects of friction and mass transfer, and the effects of simplifying assumptions for solving the equations. Instrumentation requirements and the sensitivity of computed thrust to transducer errors are presented. NASA altitude facility tests on F100 engines (computed thrust versus measured thrust) are presented, and calibration factors obtained on one engine are shown to be applicable to the second engine by comparing the computed gross thrust. It is concluded that this thrust method is potentially suitable for flight test application and engine maintenance on production engines with a minimum amount of instrumentation.

Hamer, M. J.↗

Mineralogical, Elemental and Tomographic Reconnaissance Investigation for CLPS (“METRIC”)

METRIC comprises a suite of two instruments in a Lunar lander that perform X-ray diffraction (XRD) for mineral structure, X-ray fluorescence (XRF) for elemental composition, and X-ray Micro Computed Tomography (XCT) for 3D internal micromorphology. The instruments are accompanied by optical-near IR cameras to provide local geologic context. The Honeybee Robotics PlanetVac pneumatic sampling and transfer system [1],positioned on a lander footpad, will deliver sieved regolith to the X-ray instruments for analysis. The instrument suite is intended for delivery to the lunar surface on a Commercial Lunar Payload Services (CLPS) lander. The METRICXRD/F instrument draws on heritage from the Mars Science Laboratory CheMin instrument [2] and improves upon the design in multiple ways [3]. Like CheMin, Rietveld refinement and full-pattern fitting of METRIC XRD data can identify minerals at a detection limit of ~1 wt.%, quantify their abundances when present at >3 wt.%, and determine mineral composition (e.g., Fo#in olivine) from lattice parameters for minerals present at >5 wt.%[4,5]. An optimized XRF geometry provides for improved detection and quantification of major, minor and trace elements. The METRIC XCT instrument is a miniaturized X-ray Computed Tomography scanner[6]. Lunar regolith is delivered to a 3 mm diameter, 10 mm long graphite tube inside the instrument. The tube is rotated through 360°in 0.9deg.incrementsand a divergent point source X-ray beam is directed through the material. A Charge Coupled Device (CCD)records attenuation images whose brightness and contrast area function of average atomic number and density. Quantitative data, including particle and void sizes, 3D particle shape parameters, modal volumes and pore geometry can be derived from the resulting 3D reconstructions(voxel resolution: 30 μm). Crystal morphologies derived from METRIC XCT data complement the bulk mineralogy determined by the METRIC XRD/F and provide a measure of grain size distribution for the different phases. Taken together, the METRIC instrument suite determines crystal structure, elemental composition and morphology, three principal characteristics of geological materials that are highly useful in determining the origin and subsequent processing of lunar regolith.

Moon↗

Forward modeling of Doppler velocity interferometer system for improved shockwave measurements

We report that when near-instantaneous shocks are recorded by using a Doppler velocity interferometer velocity interferometer system for any reflector (VISAR), they typically exceed the detector’s ability to react and “skipped fringes” result, where its visibility briefly reduces. Traditionally, replacing skipped fringes required guesswork in analysis, which increased arrival time errors. Second, the use of long but velocity-sensitive interferometer delays with fast detectors which can resolve the delay has traditionally been avoided because of the fear of confusing the arrival time signal. However, shorter delays produce smaller fringe phase shifts per velocity and, thus, can decrease velocity precision. We realize that while some loss of fringe information occurs at shock events, this is often just a partial loss and the residual fringe information can still hold valuable information. We describe a forward model (FM) of the interferometer action and detector blurring that assists with VISAR fringe analysis at skipping events: (1) more precise shock arrival times, (2) arrival time precision not limited by long delays, and (3) improved ghost subtraction, which improves accuracy over a broad time region. Lastly, we demonstrate the utility of a FM on National Ignition Facility and Laboratory for Laser Energetics Omega shots and discuss data process methods to increase the high time resolution of VISAR systems despite their limitations and complexities.

47 OTHER INSTRUMENTATION↗

Material Protection, Accounting, and Control Technologies (MPACT) Advanced Integration Roadmap

The development of sustainable advanced nuclear fuel cycles is a long-term goal of the Office of Nuclear Energy’s (DOE-NE) Fuel Cycle Technologies program. The Material Protection, Accounting, and Control Technologies (MPACT) campaign is supporting research and development (R&D) of advanced instrumentation, analysis tools, and integration methodologies to meet this goal (Miller, 2015). This advanced R&D is intended to facilitate safeguards and security by design of fuel cycle facilities. The lab-scale demonstration of a virtual facility, distributed test bed, that connects the individual tools being developed at National Laboratories and university research establishments, is a key program milestone for 2020. These tools will consist of instrumentation and devices as well as computer software for modeling, simulation and integration.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Creation of Anatomically Accurate Computer-Aided Design (CAD) Solid Models from Medical Images

Most surgical instrumentation and implants used in the world today are designed with sophisticated Computer-Aided Design (CAD)/Computer-Aided Manufacturing (CAM) software. This software automates the mechanical development of a product from its conceptual design through manufacturing. CAD software also provides a means of manipulating solid models prior to Finite Element Modeling (FEM). Few surgical products are designed in conjunction with accurate CAD models of human anatomy because of the difficulty with which these models are created. We have developed a novel technique that creates anatomically accurate, patient specific CAD solids from medical images in a matter of minutes.

Stewart, John E.↗

Automating the Analytical Laboratories Section, Lewis Research Center, National Aeronautics and Space Administration: A feasibility study

The feasibility of computerized automation of the Analytical Laboratories Section at NASA's Lewis Research Center was considered. Since that laboratory's duties are not routine, the automation goals were set with that in mind. Four instruments were selected as the most likely automation candidates: an atomic absorption spectrophotometer, an emission spectrometer, an X-ray fluorescence spectrometer, and an X-ray diffraction unit. Two options for computer automation were described: a time-shared central computer and a system with microcomputers for each instrument connected to a central computer. A third option, presented for future planning, expands the microcomputer version. Costs and benefits for each option were considered. It was concluded that the microcomputer version best fits the goals and duties of the laboratory and that such an automted system is needed to meet the laboratory's future requirements.

Boyle, W. G.↗

Automated Instrumentation, Monitoring and Visualization of PVM Programs Using AIMS

We present views and analysis of the execution of several PVM (Parallel Virtual Machine) codes for Computational Fluid Dynamics on a networks of Sparcstations, including: (1) NAS Parallel Benchmarks CG and MG; (2) a multi-partitioning algorithm for NAS Parallel Benchmark SP; and (3) an overset grid flowsolver. These views and analysis were obtained using our Automated Instrumentation and Monitoring System (AIMS) version 3.0, a toolkit for debugging the performance of PVM programs. We will describe the architecture, operation and application of AIMS. The AIMS toolkit contains: (1) Xinstrument, which can automatically instrument various computational and communication constructs in message-passing parallel programs; (2) Monitor, a library of runtime trace-collection routines; (3) VK (Visual Kernel), an execution-animation tool with source-code clickback; and (4) Tally, a tool for statistical analysis of execution profiles. Currently, Xinstrument can handle C and Fortran 77 programs using PVM 3.2.x; Monitor has been implemented and tested on Sun 4 systems running SunOS 4.1.2; and VK uses XIIR5 and Motif 1.2. Data and views obtained using AIMS clearly illustrate several characteristic features of executing parallel programs on networked workstations: (1) the impact of long message latencies; (2) the impact of multiprogramming overheads and associated load imbalance; (3) cache and virtual-memory effects; and (4) significant skews between workstation clocks. Interestingly, AIMS can compensate for constant skew (zero drift) by calibrating the skew between a parent and its spawned children. In addition, AIMS' skew-compensation algorithm can adjust timestamps in a way that eliminates physically impossible communications (e.g., messages going backwards in time). Our current efforts are directed toward creating new views to explain the observed performance of PVM programs. Some of the features planned for the near future include: (1) ConfigView, showing the physical topology of the virtual machine, inferred using specially formatted IP (Internet Protocol) packets: and (2) LoadView, synchronous animation of PVM-program execution and resource-utilization patterns.

Mehra, Pankaj↗

ARMing the Edge: Demonstration of Edge Computing Field Campaign Report

Edge computing enables “next-to-instrument” control and intelligent data volume reduction and the potential for autonomous, adaptive measurement strategies such as for automated control of scan strategies for Doppler lidar (DL). Instruments with narrow bandwidth connections (e.g., ship and remote sites) can do scene determination and save phenomenon-appropriate data. For example, Doppler spectrum can be saved when clouds are detected by the instrument or automatic moment detection can take place in camera images and only preserve spectrum when non-monomodal spectra are detected. Automated control at the edge involves changing the sampling (temporal or scanning strategy) of an instrument to suit the phenomena both present and being studied (Jackson et al. 2020). Both data processing and instrument control introduces the possibility of a software-defined instrument.

54 ENVIRONMENTAL SCIENCES↗

Web-Enabled Optoelectronic Particle-Fallout Monitor

A Web-enabled optoelectronic particle- fallout monitor has been developed as a prototype of future such instruments that (l) would be installed in multiple locations for which assurance of cleanliness is required and (2) could be interrogated and controlled in nearly real time by multiple remote users. Like prior particle-fallout monitors, this instrument provides a measure of particles that accumulate on a surface as an indication of the quantity of airborne particulate contaminants. The design of this instrument reflects requirements to: Reduce the cost and complexity of its optoelectronic sensory subsystem relative to those of prior optoelectronic particle fallout monitors while maintaining or improving capabilities; Use existing network and office computers for distributed display and control; Derive electric power for the instrument from a computer network, a wall outlet, or a battery; Provide for Web-based retrieval and analysis of measurement data and of a file containing such ancillary data as a log of command attempts at remote units; and Use the User Datagram Protocol (UDP) for maximum performance and minimal network overhead.

Lineberger, Lewis P.↗

Coupling a Computational Fluid Dynamics Model to a Spacecraft Thermal System Model for the DraMS Instrument Thermal Analysis

The Dragonfly Mass Spectrometer (DraMS) is an instrument on the Dragonfly mission, which will spend 7 years in deep space cruise before landing and operating on the surface of Titan. Vacuum thermal analyses are required for deep space cruise, and convection analyses are required for the Titan surface operations. Model exchanges across multiple thermal teams are needed for all phases of the mission. For DraMS, Thermal Desktop® (TD) has been the main thermal analytical tool of choice due to its capability in modeling complex thermal systems with relatively low computational power and for its availability across thermal teams. However, TD does not have computational fluid dynamics (CFD) capability and struggles to accurately capture complex convective behavior. DraMS has fans operating in tandem and gas flow behaviors are not easily predicted due to its complex flow paths. CFD software, such as Fluent, can model and predict such complex flow behaviors, but CFD models are computationally expensive, and its workflow processes are not tailored towards simulating large and complex systems. Therefore, a coupled modeling approach was chosen for DraMS: A TD model was used for simulating all the conductive, radiative, and source terms, while a Fluent CFD model was added on, as needed, to the TD model to provide the convective boundary conditions using the System Coupling software. The coupling software allows the TD and Fluent models to communicate data and arrive at a co-solved and co-converged solution. Furthermore, Thermal Iso-value Exchange (TIE) method was developed to facilitate and improve the TD-Fluent data exchange process. This paper will discuss the analytical studies that were done to verify the accuracy and usability of the coupled approach and the challenges associated, which lead to the development of the TIE approach. DraMS thermal design and co-solved analysis results will also be discussed.

Heat transfer↗