Search NASA⌕ Search

SEARCH · Search NASA

Results for “Configuration Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Insight into the deformation features and capacity loss mechanisms of lithium-ion pouch cells under spherical indentation conditions

Mechanical deformation under extreme conditions is one of the important reasons for the failure of lithium-ion batteries in automotive application. However, the deformation features and component failure of lithium-ion cells to external loading has never been a design consideration. Here, in this study, we conduct spherical indentation tests on a dozen of lithium-ion cells with different capacities under different control mode conditions to investigate their deformation features and capacity loss mechanisms. The experimental results show that, under mechanical deformation conditions, internal faults of cells occur in stages, and energy accumulation and sudden release are two key processes of cell's mechanical failure. The cells' state of charge is the main factor affecting their thermal runaway behaviors. In addition, a finite element model is developed to simulate the deformation features and the failure mechanism of key components of lithium-ion pouch cells; the 3D x-ray computed tomography is employed to demonstrate its internal configuration. With this model, the force-strain response, the deformation features as well as the size of the failure area of lithium-ion cells under spherical indentation conditions are accurately predicted. In 3D x-ray computed tomography images, unique mud cracks in cooper current collector are observed, and the influence mechanisms of the isolated fragments on the cell capacities are revealed. These results may provide useful information for the mechanical structure design of the components of lithium-ion pouch cells.

25 ENERGY STORAGE↗

Systems Analysis of Biomass and Coal Co-firing Power Plants with Deep Carbon Capture Toward Net-zero Emissions

Achieving a net-zero emission economy in the United States requires integrating diverse low-carbon and negative-emission technologies into the existing fossil fuel-dominant power fleet. Potential technologies from the low-carbon portfolio include renewable power, fossil power with carbon capture and storage (CCS), bioenergy with CCS (BECCS), and direct air capture (DAC). Renewable power is a clean energy source but has to pair with costly battery storage to provide dispatchable electricity. Fossil power with CCS offers dispatchable electricity yet still relies on DAC to offset residual emissions, even when deploying deep CCS with more than 90% CO2 capture. Coal-biomass co-firing with CCS, a subset of BECCS, is a reliable energy production technology that can be retrofitted from existing electricity generation units (EGUs). Power plant retrofit maximizes the use of the current U.S. coal power fleet without the need for large-scale deployment of new renewable power, battery storage, or DAC. Retrofitting coal-biomass co-firing with deep CCS in EGUs is a promising option, but not a universal solution. Biomass co-firing at a power plant introduces economic challenges and indirectly poses pressure on land and water resources. Meanwhile, retrofitting deep CCS affects plant efficiency and raises electricity generation costs. Overall, the technical feasibility and economic viability of plant retrofits vary across EGUs, as they are contingent upon the regional availability of biomass, unit-specific characteristics, site-specific fuel supply costs, and adjacent CO2 storage potential. Government incentives like 45Q can improve the retrofit viability, though the impact requires further quantification. A comprehensive analysis at the unit level is essential to address the question regarding the fate of the U.S. coal-fired electricity generation fleet toward the net-zero emission goal. This study conducts a systematic techno-economic-environmental assessment of EGUs to identify the viability of biomass co-firing and deep CCS retrofits in the U.S. coal-fired power fleet. Specifically, it characterizes the techno-economic performance of deep carbon capture, estimates life cycle greenhouse gas (GHG) emissions, and conducts a fleet-level assessment on retrofit viability. The key objectives are (1) to estimate the unit-specific performance and retrofitted cost under various biomass co-firing levels and CO2 capture rates; (2) to determine the possibility of reaching net-zero emission at the fleet level; (3) to quantify the cumulative capacities that are suitable for plant retrofits under current and future biomass supply scenarios; and (4) to improve the understanding of policy impacts on such retrofits to help the power sector’s transition to a net-zero economy. Techno-economic Model of Deep Carbon Capture. This study develops the performance and economic models for Monoethanolamine-based post-combustion CO2 capture at 95–99% capture rates. The process is simulated in Aspen Plus, analyzing the performance of carbon capture technology by varying the plant sizes, solvent lean loading, CO2 concentrations, and flue gas inlet temperature. Based on the key inputs and output parameters of CO2 capture, a reduced-order performance model of deep carbon capture is formulated. In addition, an engineering-economic model integrating the performance metrics is developed to estimate the capital as well as operation and maintenance (O&M) costs. Capital cost estimations follow the framework of the Integrated Environmental Control Model (IECM) and incorporate data regressions from three technical reports by IECM, the National Energy Technology Laboratory (NETL), and the National Renewable Energy Laboratory. The O&M cost estimation utilizes the actual inventory consumption rate and labor requirements. Both performance and cost models are embedded into IECM v13.0-beta, a fossil-fuel power plant modeling tool. Life Cycle Assessment of Power Plants. This study estimates the GHG emissions of power plants through life cycle assessment (LCA). The LCA scope includes fuel supply, combustion-based power generation, and CO2 transport and storage. The fuel-based life cycle module is designed following the framework of the NETL Unit Process Library and CO2U LCA Guidance Toolkit. The module is then incorporated into IECM v13.0-beta. The process-based LCA is applied to estimate the GHG emissions of coal and biomass supply, coal- and coal-biomass co-firing power plant operation, as well as CO2 pipeline transport and geographical sequestration. An uncertainty analysis is conducted to quantify the variability and uncertainty associated with the LCA using the Latin Hypercube Sampling (LHS) method. Fleet-level Assessment. This study evaluates the technical and economic feasibility of selected coal-fired EGUs, examines the role of tax credits in retrofit viability, and assesses the competitiveness of retrofitted units against other low-carbon options. Unit screening identifies EGUs for the study, focusing on new, efficient baseload units with air pollution controls. The power plant databases are then established to organize unit-specific information on performance and operating conditions from the relevant public databases. Biomass for co-firing retrofits is selected based on home and neighboring county availability, ensuring sustained operation with at least a 5% co-firing level. The CO2 storage site is determined by state-level storage potential, with ArcGIS Pro and NETL CO2 Saline Storage Cost Model used to identify the optimal balance between the nearest transport distances and affordable storage costs. The latest IECM v13.0-beta is then employed to configure and evaluate the eligible EGUs with or without the deployment of deep CCS and biomass co-firing. A supply curve is established to illustrate the cumulative installed capacity suitable for retrofits at different cost levels. A sensitivity analysis on tax credits for carbon sequestration is performed. Finally, a unit-level cost comparison is conducted among retrofitted plants, renewable power with battery storage, and abated fossil fuels with DAC. Expected Results. This study evaluates the technical, economic, and environmental metrics of each EGU across an array of CO2 capture rates and biomass co-firing level scenarios. Unit-level comparisons will identify critical factors influencing technical performance. The supply curves with and without tax incentives will provide insights into the impact of tax credits on biomass co-firing and CCS deployment. The cost comparisons with renewables and DAC-retrofit will assess the competitiveness of the retrofitted units. Life cycle emissions from each unit will be assessed to identify the scenarios under which net-zero emissions can be achieved. These analyses are expected to determine the total coal-fired capacity suitable for serving as a low-carbon energy source with or without tax incentives. The study results are novel in identifying optimal unit-specific strategies for producing carbon-neutral power, whether through retrofitting EGUs with deep CCS, biomass co-firing, DAC, or installing renewable power with battery. The findings will provide insight into nationwide efforts to ensure reliable, affordable, and low-carbon electricity. It also will inform investment decisions and policies in the deployment of deep carbon capture and negative emission technologies for a net-zero energy future.

Biomass Co-firing↗

Particle control via cryopumping and its impact on the edge plasma profiles of Alcator C-Mod

At the high n e proposed for high-field fusion reactors, it is uncertain whether ionization, as opposed to plasma transport, will be most influential in determining n e at the pedestal and separatrix. A database of Alcator C-Mod discharges is analyzed to evaluate the impact of source modification via cryopumping. The database contains similarly-shaped H-modes at fixed I P = 0.8 MA and B t = 5.4 T, spanning a large range in P net and ionization. Measurements from an edge Thomson scattering system are combined with those from a midplane-viewing Ly α camera to evaluate changes to n e and T e in response to changes in ionization rates, S ion ∙ $n^{sep}_e$ and $T^{ped}_e$ are found to be most sensitive to changes to $S^{sep}_{ion}$, as opposed to $n^{ped}_e$ and $T^{sep}_e$. Dimensionless quantities, namely α MHD and v*, are found to regulate attainable pedestal values. Select discharges at different values of P net and in different pumping configurations are analyzed further using SOLPS-ITER. It is determined that changes to plasma transport coefficients are required to self-consistently model both plasma and neutral edge dynamics. Pumping is found to modify the poloidal distribution of atomic neutral density, n 0 , along the separatrix, increasing n 0 at the active X-point. Opaqueness to neutrals from high n e in the divertor is found to play a role in mediating neutral penetration lengths and hence, the poloidal distribution of neutrals along the separatrix. Pumped discharges thus require a larger particle diffusion coefficient than that inferred purely from 1D experimental profiles at the outer midplane.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Magnetic order in nanogranular iron germanium (Fe 0.53 Ge 0.47 ) films

We study the effect of strain on the magnetic properties and magnetization configurations in nanogranular Fe x Ge 1-x films (x = 0.53 ± 0.05) with and without B20 FeGe nanocrystals surrounded by an amorphous structure. Relaxed films on amorphous silicon nitride membranes reveal a disordered skyrmion phase while films near and on top of a rigid substrate favor ferromagnetism and an anisotropic hybridization of Fe d levels and spin-polarized Ge sp band states. The weakly coupled topological states emerge at room temperature and become more abundant at cryogenic temperatures without showing indications of pinning at defects or confinement to individual grains. These results demonstrate the possibility to control magnetic exchange and topological magnetism by strain and inform magnetoelasticity-mediated voltage control of topological phases in amorphous quantum materials.

36 MATERIALS SCIENCE↗

Extending the operational boundaries of RMP-ELM suppression with optimized 3D field control

The use of 3D magnetic fields is one of the promising approaches to control edge localized modes (ELMs), and ITER has plans to utilize a flexible 3D coil set for ELM suppression using 3D fields. This study focuses on optimizing the 3D field spectrum to expand the operational window for n = 1 resonant magnetic perturbation (RMP) ELM suppression in KSTAR. The optimized n = 1 RMP effectively suppresses ELMs throughout the entire H-mode discharge, including the first ELM crash, while avoiding the onset of disruptive locked modes in low-density L-mode plasmas. The predicted suppression window aligns well with experimental data, highlighting the challenges and solutions of using n = 1 RMP at low densities. Moreover, the optimization successfully achieved n = 1 RMP ELM suppression for the first time in ITER-relevant q 95 and shaping conditions, including cases with q95 as low as 3.6, as well as other q 95 and shape configurations. This highlights the importance and utility of 3D coil optimization while emphasizing the potential of long-wavelength low-n RMP, which will be valuable for ex-vessel coils designed to avoid complications of nuclear degradation.

3D magnetic field control↗

Liquid lithium divertor analysis using coupled plasma material interaction model

A liquid lithium divertor can improve performance of future fusion devices by creating efficient power exhaust and improving the energy confinement via pumping of the hydrogen isotopes. In addition, significantly higher heat fluxes can be handled if controlled vapor shielding is used to redistribute the divertor heat flux over a wider area. Design and optimization of such a system calls for an analysis model which includes a strong two-way coupling between the plasma and divertor material. The incoming plasma heat and particle flux will affect the divertor surface temperature, which is a defining factor of the lithium evaporative and sputtered flux going into the plasma. Results of the coupled model based on the plasma edge code SOLPS-ITER and the computational fluid dynamics (CFD) code ANSYS-CFX will be presented for different configurations. An analytical slab flow model is used as a heat transfer boundary condition for SOLPS, defining particle flux from the wall via calculation of the surface temperature. At the final step, results of the SOLPS analysis are verified using a 3D CFD magnetohydrodynamics (MHD) analysis which uses heat and particle flux from SOLPS as a boundary condition. In addition to plasma heat flux, both analytical and CFD temperature models include several plasma material interaction effects, such as lithium evaporation, condensation and sputtering based on deuterium target flux. New adatom sputtering model based on the available experimental data is presented. Analytical model is expanded to include free surface axisymmetric configurations. Results of parametric studies of the divertor configurations with different lithium inlet temperature and velocity will be presented leading to the optimal design resulting in the lowest possible lithium contamination in the core.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-Situ Magnetic Field Reconstruction in the MAGIS-100 Experiment

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.; Ferm↗

Electromagnetic Energy-Assisted Thermal Conversion of Fossil-Based Hydrocarbons to Low-Cost Hydrogen

The goal of this project was to develop and optimize catalysts for methane decomposition, particularly focusing on regeneration via an electromagnetic energy-assisted mechanism, to produce hydrogen more cost-effectively compared to electrolysis routes. To achieve this goal, the project pursued several key objectives. The project began with the preparation and testing of various catalysts. A nickel-silica based catalyst was identified as the most promising material for the pyrolysis of methane into carbon and hydrogen. Kinetic parameters for methane decomposition were determined, aiding in computational modeling efforts. Structured catalysts were investigated, highlighting the need for frequent cleaning or regeneration to maintain performance, with methane conversion rates exceeding 70% in tube furnace tests. Computational fluid dynamics modeling was employed to optimize reactor designs and electrode angles, leading the project team to propose a multi-compartment thermal conversion system for larger setups. This modeling work was important in understanding reaction characteristics, carbon deposition rates, and temperature profiles under various conditions. A bench-scale reactor system was assembled to evaluate catalyst regeneration using electromagnetic energy-assisted mechanisms. Experiments demonstrated the potential for carbon removal, though further optimization is needed. The carbon produced from the methane conversion process was evaluated for potential use in lithium-ion battery electrodes. The carbon exhibited properties similar to commercially available high-purity multi-walled carbon nanotubes and nanofibers, with a carbon content greater than 95%. Coin cell batteries assembled with this carbon showed that lower replacement levels (10% to 33%) outperformed the control group, improving specific capacity density and stability. However, higher replacement levels (100%) demonstrated poorer performance, suggesting that excessive carbon substitution negatively impacts battery performance. These findings indicate the potential marketability of the produced carbon as a component in lithium-ion batteries, though further testing is necessary to confirm long-term advantages and disadvantages associated with the use of the carbon product. These results however justified further technoeconomic assessments to determine if the process can provide low-cost hydrogen. The economic feasibility and technical performance of methane decomposition for hydrogen production were assessed, focusing on three plant configurations: 100E (electrically heated), 100C (combustion heated using produced hydrogen), and PE-Hybrid (a combination of pyrolysis (indicating decomposition) and electrolysis). The Levelized Cost of Hydrogen (LCOH) for the pyrolysis configurations was found to be approximately 25% lower than that of electrolysis. The 100E configuration had the lowest LCOH at $\$$3.12/kg. Including carbon product sales significantly improved the economics, with the 100C configuration achieving a negative LCOH of -$\$$0.35/kg. The PE-Hybrid configuration was not economically advantageous compared to pure pyrolysis plants due to its complexity and additional equipment requirements. Ultimately, methane pyrolysis presents a viable method for near carbon dioxide-free hydrogen production, with significant economic advantages over electrolysis, especially when considering the sale of carbon byproducts. The 100E and 100C configurations showed the most promise, with the choice between them ultimately depending on the prices of power and natural gas. In conclusion, this technology has the potential to lower hydrogen production costs by leveraging the methane decomposition process with the sale of valuable carbon byproducts. By optimizing catalyst performance and integrating electromagnetic energy-assisted regeneration, the process can achieve higher efficiency and economic viability, making it a competitive alternative to traditional hydrogen production methods.

08 HYDROGEN↗

Integration of Online Cross-Section Generation Capability with Depletion and Transient Solvers in Griffin

Griffin is a Multiphysics Object-Oriented Simulation Environment (MOOSE)-based reactor multiphysics analysis application jointly developed by Argonne and Idaho National Laboratories under the DOENE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. In FY25, an online crosssection generation capability based on the Self-Shielding Application Programming Interface (SSAPI) was demonstrated for TRISO-fueled reactor problems under steady-state conditions. This fiscal year, that capability was extended to support depletion and transient multiphysics calculations, enabling high-fidelity analyses that generate self-shielded cross sections on the fly from the actual evolving composition and temperature states rather than from pre-tabulated libraries. For depletion, a two-way coupling was established in which SSAPI computes compact-averaged self-shielded cross sections that the depletion solver then uses to advance the Bateman equations, with the updated compositions returned to SSAPI at each step; the depletion module was refactored to support both library-based and SSAPI-based cross sections, and additional logic was added to track daughter isotopes and to exclude minor isotopes for efficiency. For transient analysis, the SSAPI multigroup library was extended with the kinetics data required for time-dependent calculations, the Improved Quasi-Static (IQS) scheme was coupled with SSAPI, and several supporting capabilities were implemented, including a self-shielding treatment that lets control rods and drums move within a self-shielded model, which had previously been impossible and had ruled out rod- and drum-movement transients with on-the-fly cross sections altogether, a new mixing scheme for delayed-neutron precursor decay constants, a checkpoint-based restart workflow, and performance improvements such as pointwise cross-section interpolation and the bypassing of unnecessary Dancoff factor calculations. The implemented capabilities were verified against Serpent Monte Carlo solutions. For depletion, a prismatic pin-cell problem based on a Next Generation Nuclear Plant (NGNP) Very High Temperature Reactor benchmark showed excellent agreement, with eigenvalue differences within 200 pcm over the entire burnup range (up to 140 MWD/kgU) and fission-product and actinide inventories agreeing to within 0.8% and 2.5%, respectively; a heat-pipe microreactor assembly problem with a much higher fuel loading confirmed the same behavior and quantified the bias introduced when the multigroup equivalence effect is neglected. For transient analysis, a pin-cell problem with a step reactivity insertion and temperature feedback reproduced the analytically expected asymptotic power and showed close agreement between the direct and IQS solutions, and a two-dimensional microreactor core problem with control-drum rotation exercised the new moving-drum self-shielding treatment and demonstrated successful coupling of the online crosssection generation with both the direct and IQS transient methods. The capability was further exercised on a full-core pebble-bed problem, in which Griffin was coupled with the System Analysis Module (SAM) to simulate load-following operation of the gPBR with the Doppler feedback resolved at the TRISO fuel kernel temperature. These developments in Griffin provide a convenient, high-fidelity approach to cross-section generation for advanced thermal reactors with geometrically complex and highly heterogeneous configurations, including TRISO-fueled prismatic and pebble-bed systems, and support steady-state, depletion, and transient multiphysics calculations. They also enable self-shielded cross sections to be evaluated directly at the actual coupled state of the system, thereby establishing a foundation for high-fidelity, fully coupled multiphysics analysis of advanced reactors

Park, H.↗

Controlling matric potential in microfluidics to examine microbial dynamics in unsaturated porous media

The use of microfluidics for the study of soil microbial ecology is an emerging field. Most microfluidic studies of biological systems, however, have been performed under fully saturated conditions that are not representative of natural soil. Therefore, while microfluidics offer many unique capabilities that other methodologies cannot, they are not currently suited to address the effects of matric potential, an important variable defining the microbial moisture niche. Here, a methodology is presented that allows the user to control the aqueous conditions within microfluidic networks by manipulating matric potential using a hanging water column. The method relies on hydrophilic surface treatment of the microfluidic device using polyvinyl alcohol (PVA) and incorporating a bed of small pores at the network boundaries, which serve as a porous ceramic plate analogue (PPA). The method was validated on a simple capillary bundle and then on a more complex pore network. A water retention curve, exhibiting hysteresis, was generated for the pore network over a narrow matric potential range of 0 to – 5 kPa. Both the drainage and wetting curves were reproducible, as were the spatial configuration and the number of fragmented moisture niches in the pore network, particularly on the drainage curve. In contrast, the wetting curve exhibited greater variability in spatial configuration due to the “ink bottle effect,” where capillarity was interrupted by wider pore bodies. Ultimately, the methodology provides realistic pore-scale moisture conditions that can be easily manipulated and maintained, enabling new opportunities to explore soil biophysics and microbial biogeography in unsaturated porous media. As a brief example, images showing the localization of fluorescently tagged Pantoea sp. YR343 at −4.3 kPa are presented, highlighting bacterial distributions in water films and air-water interfaces.

59 BASIC BIOLOGICAL SCIENCES↗

Dynamic Modeling of Latent Heat Thermal Battery

A dynamic thermodynamic model is constructed in Modelica for the thermal battery portion of a heat pipe integrated thermal battery and is demonstrated using a shakedown test. The model is also leveraged to inform aspects of an experiment configuration. The theory section discusses modeling assumptions of the thermal battery system, establishes how melting and fusing is calculated, and how internal convection is modeled within the thermal battery. The shakedown test uses three charge-standby-discharge-standby cycles in which the charging cycles are 10 hours in length and the discharge cycles are 8 hours. System behavior including heat loss, temperature distributions and divergences, and internal convection behavior are presented. The model is then leveraged to show how experiment design can be informed through testing the model for insulation thickness impact on heat loss, round trip efficiency calculation, and heat tracing control.

25 ENERGY STORAGE↗

ClassNMSW- a real-time classification approach for non-recycled municipal solid waste using hyperspectral imaging

Real-time classification of non-recycled municipal solid waste (NMSW) is essential for efficient valorization. This study introduces ClassNMSW, a comprehensive framework for classifying 22 NMSW subclasses under industrial constraints by using hyperspectral imaging (HSI). A primary innovation of this work is the development of a variance-controlled spectral extraction algorithm. Unlike traditional methods that rely on simple averaging, this approach systematically investigates the extent of pixel extraction to minimize the loss of critical chemical information while maximizing data reduction thus ensuring high spectral fidelity with low computational cost. The approach developed in this work integrates automated, computer-vision-based background removal, eliminating the need for the manual thresholding common in current literature. To resolve ambiguities among chemically similar subclasses, a tiered classification and multi-camera fusion strategy (NIR17 and NIR22) is implemented. Results demonstrate that ClassNMSW achieves an object-wise weighted accuracy of 98.70% for single-sensor configurations and 100% under sensor fusion. A novel rolling-window strategy satisfies desired end-to-end latency of <2 s, satisfying the strict deterministic requirements of high-speed industrial sorting environments. The ClassNMSW framework provides a scalable foundation for advancing circularity and resource recovery in large-scale waste valorization operations.

99 - GENERAL AND MISCELLANEOUS↗

Fluorine-Tuned Carbon-Based Nickel Single-Atom Catalysts for Scalable and Highly Efficient CO 2 Electrocatalytic Reduction

Electrocatalytic CO 2 reduction is garnering significant interest due to its potential applications in mitigating CO 2 and producing fuel. However, the scaling up of related catalysis is still hindered by several challenges, including the cost of the catalytic materials, low selectivity, small current densities to maintain desirable selectivity. In this study, Fluorine (F) atoms were introduced into an N-doped carbon-supported single nickel (Ni) atom catalyst via facile polymer-assisted pyrolysis. This method not only maintains the high atom utilization efficiency of Ni in a cost-effective and sustainable manner but also effectively manipulates the electronic structure of the active Ni-N 4 site through F doping. The catalyst has also been further optimized by controlling the F states, including convalent and semi-ionic states, by adjusting the fluorine sources involved. Consequently, this catalyst with unique structure exhibited comparable electrocatalytic performance for CO 2 -to-CO conversion, achieving a Faradaic efficiency (FE) of over 99% across a wide potential range and an exceptional CO evolution rate of 9.5 x 10 4 h -1 at -1.16 V vs reversible hydrogen electrode (RHE). It also delivered a practical current of 400 mA cm -2 while maintaining more than 95% CO FE. Experimental analysis combined with density functional theory (DFT) calculations have also shown that F-doping modifies the electron configuration at the central Ni-N 4 sites. In conclusion, this modification lowers the energy barrier for CO 2 activation, thereby facilitating the production of the crucial *COOH intermediate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing Operational Safety via Agentic Dialogue Hazard Identification Analysis

Operational safety in high-stakes domains such as industrial process control, autonomous, and safety-critical systems demand reliable hazard identification. While large language models (LLMs) have shown promise in automating safety analysis tasks, single-turn, monolithic inference is brittle: it lacks the self-correction, deliberation, and contextual refinement that safety engineers apply iteratively. In this paper, we introduce HAZDIAL, a framework that investigates whether structured agentic dialogue (multi-agent, multi-turn interactions) improves the quality of NLP-based hazard identification over single-pass baselines. We systematically compare two dialogue modalities: adversarial debate and constructive discussion, and propose an genetic algorithm-based agentic interaction optimization. We evaluate all configurations against a curated golden dataset using standard classification metrics (accuracy, precision, recall, F1) and a novel dialogue metrics. This work advances the intersection of dialogue systems, multi-agent reasoning, and AI safety, providing empirical evidence for dialogue-driven hazard analysis.

Das, Sanjay [ORNL] (ORCID:0009000542591915)↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrostatic Gating of Ionic Conductance through Heterogeneous van der Waals Nanopores

Nanofluidic ionic transistors typically require gate voltages above 1 V and operate only at submillimolar ionic strengths, limiting their biocompatible applications. We demonstrate ionic transistors consisting of single sub-10 nm nanopores drilled in van der Waals (vdW) heterostructures with internal gate electrodes made of few-layer graphene. These devices deliver up to 10-fold current modulation at gate voltages as low as 0.3 V in 10 mM KCl, and ∼2-fold modulation at near-physiological 100 mM KCl. Baseline conductance with no gate shows surface-charge-dominated transport below 100 mM KCl, consistent with negatively charged hBN walls and ∼5 nm opening of the pores. The surface charge and the electrochemical asymmetry introduced by the three-electrode configuration govern the device’s behavior: negative gate voltage (V G ) enriches ionic concentrations and enhances current, whereas positive V G induces a local depletion zone that suppresses transport. The current modulation by V G is dependent on the polarity of the transmembrane potential and leads to ion current rectification. Molecular dynamics simulations of a nanopore in a hBN–graphene–hBN stack reveal confinement and surface charge-dependent suppression of the relative permittivity of interfacial water. Continuum modeling with radially varying interfacial water permittivity reproduces the asymmetric I–V characteristics and explains how the embedded gate sculpts local potential and ion concentrations. By enabling sub-0.5 V control of ionic transport at up to 100 mM salt concentrations, these devices address a key need in nanofluidics to create low-power ionic circuits and biosensing.

Materials science↗

Adaptive stretching of representations across brain regions and deep learning model layers

Prefrontal cortex (PFC) is known to modulate the visual system to favor goal-relevant information by accentuating task-relevant stimulus dimensions. Does the brain broadly re-configures itself to optimize performance by stretching visual representations along task-relevant dimensions? We considered a task that required monkeys to selectively attend on a trial-by-trial basis to one of two dimensions (color or motion direction) to make a decision. Although effects were most prominent in frontal areas, representations stretched along task-relevant dimensions in all sites considered: V4, MT, lateral PFC, frontal eye fields (FEF), lateral intraparietal cortex (LIP), and inferotemporal cortex (IT). Spike timing was crucial to this code. A deep learning model was trained on the same visual input and rewards as the monkeys. Despite lacking an explicit selective attention or other control mechanism, by minimizing error during learning, the model’s representations stretched along task-relevant dimensions, indicating that stretching is an adaptive strategy.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of chemical disorder and spin-orbit coupling on the electronic-structure and Fermi-surface topology of YbSb-based monopnictides

Here, in this work, we study the influence of disorder on the electronic structure of YbSb—a rare-earth monopnictide featuring a simple rocksalt (B1) crystal structure and a well-defined Fermi-surface topology—by employing first-principles density-functional theory. We focus on chemical disorder introduced through Te and Al doping, selected based on their thermodynamic stability in alloyed configurations, to understand how such perturbations modify the electronic states of YbSb. Our results indicate that Te doping predominantly introduces electronlike states at the 𝑋 and 𝐿 points, while Al doping leads to a suppression of holelike states at Γ, effectively driving the system from a semimetallic state to one characterized by very narrow-gap behavior at Γ. This modulation of the Fermi surface, particularly the reduction of central hole pockets at Γ, plays a central role in altering interpocket scattering—a mechanism critical for tuning quantum transport properties, including superconductivity. This disorder-driven modulation of the Fermi surface, particularly the suppression of central hole pockets at Γ, controls interpocket scattering, which is essential for optimizing quantum transport properties, including superconductivity. Our results show that disorder can be effectively used for engineering band topology, thereby tuning quantum related response through a tailored electronic structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗