Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Account Manager”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Enabling Staged Pressurized Oxy-Combustion: Improving Flexibility and Performance at Reduced Cost

Introduction: The staged pressurized oxy-combustion (SPOC) process, developed by Washington University in St. Louis (WUSTL), is an oxy-combustion carbon capture technology that employs a steam power cycle to generate electricity. As with atmospheric-pressure oxy-combustion processes, carbon dioxide (CO 2 ) capture rates of 90% or higher can be achieved. The staged-combustion approach of the SPOC process, when operated at elevated gas pressure, allows for near elimination of flue gas recycle (FGR) and leads to significant improvements in efficiency and reduced costs. The primary goal of this project was to investigate the potential for SPOC for flexible operation beyond the capabilities of conventional coal-fired power plants, particularly those employing carbon capture and storage (CCS). Oxy-combustion differs from conventional coal combustion in that the combustion of coal is carried out using oxygen as opposed to air. The resultant flue gas is a mixture of primarily CO 2 and water, greatly simplifying CO 2 capture. As SPOC does the oxy-combustion process under pressure, it is higher efficiency and lower cost than atmospheric oxy-combustion. The project was led by the Electric Power Research Institute, Inc., with the assistance of WUSTL, Doosan Babcock (DBL – boiler plant original equipment manufacturer), and Air Liquide (AL – air separation experts). The specific objectives of the project were to: (1) Evaluate the SPOC concept and develop a risk-based approach to the heating surface layout ensuring that performance (gas and steam side), manufacturing, transportation, and plant erection considerations were fully accounted for in the system design. (2) Improve the technology to ensure its performance and cost potential are substantially better than today’s baseline pulverized coal power plant with post-combustion capture (PCC) or atmospheric oxy-combustion, and show progress toward performance commensurate with projected commercial operation, including 90% or more CO 2 capture. (3) Address critical technology gaps and improving overall system performance for the technology. (4) Perform combustion tests at scale under commensurate pressure to the commercial operating system validate combustor and advance the SPOC combustion modeling tools that will facilitate full-scale design. Combustion Testing: Testing was initially carried out at atmospheric pressure with methane to ensure that all systems were correctly operating. Following this, the testing then proceeded to moderate pressure operation at 4 bara, where different stoichiometric conditions were used across an extended heat input range, showing that a stable flame could be maintained. Testing then proceeded at 10 and 15 bara where it was shown that the ignition system needed to be replaced at these operating conditions. When testing recommenced, a similar stable flame shape was achieved, without any methane support, and the full 100 kWth coal oxy-combustion was demonstrated. Heat flux measurements showed 400 kW/m 2 (0.126 MMBtu/hr-ft 2 ) from the flame, within the 450 kW/m 2 (0.142 MMBtu/hr-ft 2 ) preferred limit defined by DBL for the full-scale design case. Carbon monoxide and carbon-in-ash measurements showed that complete combustion was possible with ultra-low excess oxygen at 1 vol % in the product flue gas. This allowed the full-scale models to be calculated based on this level of excess oxygen, improving the performance of the system as lower feed oxygen is produced in the air separation unit (ASU), saving auxiliary power. Full-Scale Design: The full-scale design is sized to deliver 550 MWe net electrical power output to allow direct comparison with the National Energy Technology Laboratory (NETL) baseline cases using the same Montana Powder River Basin (PRB) fuel. The cases used for direct comparison are: Case S12A (supercritical [SC] coal without CO 2 capture), Case S12B (SC coal with PCC at 90% CO 2 capture, and Case S12F (atmospheric oxy-combustion SC coal with 90% CO 2 capture). The SPOC stages were configured to be identical arrangements, allowing for a more straightforward design, construction, and control strategy. Each stage consists of two PVs, the first being the combustor PV module and the second being the convective PV module. The combustor module is the tallest vessel, with local coal feeding equipment and the burner FGR and oxygen plenums at the top and ash management at the bottom. The combustor module is effectively an open cross section with membrane tubes around the circumference – this unobstructed slender profile ensures that the relatively slower burnout mechanism needed for the low-speed turbulent mixing burner can proceed unimpeded and that molten ash will not attach to any surfaces at an angle to the predominant flue gas flow. The steam turbine used in the SPOC design is essentially the same unit utilized in the atmospheric oxy-combustion case except the degree of heat recovery possible allows the low-pressure (LP) feedwater heater train to be eliminated. This is a result of being able to capture the latent heat of evaporation of the moisture produced in the combustion (normally lost to the stack). The SPOC system outperforms the NETL atmospheric oxy-combustion baseline case by 3.3% points and the PCC case by 7.5% points. This performance increase is mainly a result of the improved heat recovery possible from the product flue gas and from the reduced auxiliary power consumption from the ASU and the CO 2 compression and purification unit over the atmospheric equivalent. The combined improvement in boiler efficiency and reduction in the steam turbine heat rate resulted in a net improvement in the overall plant efficiency by 0.61%, to 35.6% on a HHV basis. This relatively small improvement in plant efficiency between sub-bituminous and bituminous coals shows the value of useful moisture latent heat recovery offered by the SPOC system when using low rank fuels. Flexibility and Turndown: The SPOC system has inherent high turndown capabilities because of a demonstrated high range of combustion stability and the ability to bypass stages, thereby reducing steam generation rates proportionally without altering firing rates in operating stages. ASU units do not generally offer significant turndown opportunities as they are limited by the performance of the compression plant. The baseline SPOC design has a 2-train ASU configuration, needed to be able to meet the 10,500 tonnes per day duty, that can deliver efficient turndown points between 85–100% load with both trains operating, and at 45–50% load with a single train operating. Outside these operating points, the flexibility and efficiency are limited and may be uncompetitive at loads below 45% as the ASU systems are unable to turndown beyond 85% for the base case and 70% for the flexible case. The ASU cold box for the flexible case was designed to operate at loads between 40-100%, below this operating range the purity of the produced oxygen cannot be guaranteed, resulting in additional load for the CPU equipment. The additional power consumption of these cases yields an uneconomic operating condition with poor efficiency when operating at low loads such as 25% and 12%. To address this flexibility constraint, AL evaluated how the ASU configuration could be altered to deliver efficient oxygen supply over the load range. This involved integrating the compressor duties across both ASU trains into a shared duty arrangement with multiple compressors, strategically sized to deliver the duty required across all load ranges between 40–100% by enabling different combinations of the main air compressors and the booster air compressors. The oxygen purity cannot be guaranteed below 40% load for each train – the power consumption at 25% and 12% loads were estimated based on the multi-compressor configuration at maximum turndown as these load cases were not considered in the flexible ASU design. With a different cold box configuration, i.e. number of trains, the entire load range could be delivered within oxygen purity specifications. Although there is a small efficiency reduction at full load, there are significant improvements in overall plant performance during low-load operation. The exact ASU configuration needed will therefore be dependent on the expected operating profile of the unit. Economic Analysis: Cost estimates for the baseline and the flexible cases were developed using NETL baseline case data for common BOP items and an Association for the Advancement of Cost Engineering International Class 5 (conceptual/screening study) assessment of key components unique to the SPOC system. The capital, operating, and maintenance costs were assessed along with the first-year power cost, levelized cost of electricity, and CO 2 captured and avoided cost for the SPOC cases were compared against the relevant NETL baseline cases in January 2019 dollars. Both SPOC cases achieve a lower cost that the alternative NETL baseline cases (with the flexible SPOC case being slightly higher than the baseline SPOC case due to the compounded impact of higher capital costs and lower efficiency at full load). The SPOC cases deliver a lower cost of CO 2 avoided than the NETL baseline cases due to greater efficiency in generating low-carbon power. However, the cost of CO 2 captured is higher because the higher efficiency of the SPOC process generates less CO 2 , hence less needs to be captured, resulting in a high capital cost being shared over a reduced CO 2 quantity. The flexible ASU adds 1.6% overall to the plant cost in comparison to the baseline case, but the efficiency improvements at loads below 50% are significant. Subsequently, depending on the plant load-profile expectation, the flexible ASU would be beneficial if the plant spends a significant portion of its operating life below 50% load. This kind of operating profile is likely to be required for all fossil plants when more renewable electricity generators are installed on the local grid, particularly solar power that can be predicted ahead of time, allowing for appropriate pricing signals to be incorporated into the diurnal cycle. R&D Recommendations: SPOC, while a promising technology, is a relatively recent concept and, as such, operability issues of combustor design and steam-side integration for such systems at a scale relevant to commercial deployment have not been evaluated. WUSTL has conducted extensive small pilot-scale (100 kWth) research to understand and advance pressurized oxy-combustion processes, including investigation of combustion and flame characteristics, radiative heat flux, burner operability, turn down, char burnout, ash characteristics, water-wash column operation, etc. for pressurized oxy-combustion systems. Nonetheless, at this stage in the development of the SPOC process, what is needed is a large-scale pilot plant that can serve to study pressurized oxy-combustion systems and components at a scale commensurate with the maturity of the technology. A scale of 10 MWth, which includes steam-side integration and two stages would yield essential information with respect to heat transfer characteristics both in the radiative and convective sections of the pressure vessels, and the ability to operate the fuel staging process. In addition, while modeling results indicate that combustion and flame characteristics improve with scale, direct studies of the combustor at this scale will ensure that the models can be relied upon for scale up to commercial scale. Furthermore, a detailed analysis must be performed to understand the scaling aspects of key components and systems.

20 FOSSIL-FUELED POWER PLANTS↗

Cybersecurity for Distance Relay Protection

This project is a DOE follow-up effort on the CREDC workshop held on September 13, 2018 in Cambridge, MA to discuss cybersecurity of distance relays, which considered the benefits, vulnerabilities and risk mitigations for the use of communication systems in power system protection. The objectives of this project are to define the taxonomy of relay protection and associated communications; define use cases describing approaches to reduce the cyber-attack surface on those protective relays; and evaluate the loss of operational functional capability from changes to communication coverage. Mitigating controls will also be evaluated to understand if there are other approaches to reduce attack surfaces while maintaining communications or partial communications. Distance relays are used to protect transmission lines of approximately 10 to 300 miles in length, by detecting short circuits (i.e., faults) on the lines and then tripping circuit breakers in the substation. Such protection systems are a subset of the power system and they incorporate sensing, logic and communication functions. Protection system exposure to cyberattack could be drastically limited by disconnecting relays from all vulnerable communication systems, but this may adversely impact overall power system performance in the absence of cyberattack. This project began with a use case analysis of protection systems with communications, as summarized in this report. It continued with modeling, testing and evaluation in a miniature power system (MPS), located in the Western Area Power Administration (WAPA) Electric Power Training Center (EPTC). The project also incorporated feedback from two industry meetings held in February and September 2019. The suggested next steps account for and complement the work already underway with DOE/CESER funding: 1. Study the performance of LCD and PC vs. PUTT, which is less reliant on communication system performance and GPS timing references. The PUTT scheme could prove to be more resilient to cyberattack or communications-related disruption. It could also be more tolerant of message re-routing with SDN/SDR communication systems. On the other hand, it will be more vulnerable to false tripping during dynamic events or to loss of the voltage signal. The optimum choice of scheme may depend on the specific power system and risk assessment. This study could provide a new template for evaluation based on business functions. 2. Research and develop new methods to detect and monitor distributed physical attacks, possibly using drones, video sensors, thermal sensors, machine learning and other advanced techniques. This will help mitigate the impact of cyberattack on the protection system, and will also help mitigate the impact of wild fires. 3. Implement a scalable PKI for use in electric utility protection systems. This will encourage widespread adoption of secure authentication methods that are already available, but not widely used at present. This will help secure engineering access to the relays. 4. Investigate the use of SDN in combination with SDR to achieve better cybersecurity and electromagnetic security of the network, incorporating path variability. This would help secure both engineering access and peer-to-peer GOOSE messaging. 5. Perform additional testing, with operator evaluation of “red button” scenarios, PUTT vs. LCD, relay mis-operations, and other cyberattacks in the EPTC. This is an important advantage of testing in the EPTC rather than by computer simulation or even hardware-in-the-loop simulation; the EPTC is already dedicated to managing the situational awareness, operator response times and other human impacts. One of the project objectives was to settle on a common nomenclature for this problem space. We have concluded that the OSI layer model, supplemented by ANSI device numbers and other IEEE standards, is already well-accepted by the industry. The IEEE PSRC knowledge base provides a great deal of public information

24 POWER TRANSMISSION AND DISTRIBUTION↗

Workshop introduction

The Department of Energy's National Nuclear Security Administration's Global Threat Reduction Initiative (GTRI) has three subprograms that directly reduce the nuclear/radiological threat; Convert (Highly Enriched Uranium), Protect (Facilities), and Remove (Materials). The primary mission of the Off-Site Source Recovery Project (OSRP) falls under the 'Remove' subset. The purpose of this workshop is to provide a venue for joint-technical collaboration between the OSRP and the Nuclear Radiation Safety Service (NRSS). Eisenhower's Atoms for Peace initiative and the Soviet equivalent both promoted the spread of the paradoxical (peaceful and harmful) properties of the atom. The focus of nonproliferation efforts has been rightly dedicated to fissile materials and the threat they pose. Continued emphasis on radioactive materials must also be encouraged. An unquantifiable threat still exists in the prolific quantity of sealed radioactive sources (sources) spread worldwide. It does not appear that the momentum of the evolution in the numerous beneficial applications of radioactive sources will subside in the near future. Numerous expert studies have demonstrated the potentially devastating economic and psychological impacts of terrorist use of a radiological dispersal or emitting device. The development of such a weapon, from the acquisition of the material to the technical knowledge needed to develop and use it, is straightforward. There are many documented accounts worldwide of accidental and purposeful diversions of radioactive materials from regulatory control. The burden of securing sealed sources often falls upon the source owner, who may not have a disposal pathway once the source reaches the end of its useful life. This disposal problem is exacerbated by some source owners not having the resources to safely and compliantly store them. US Nuclear Regulatory Commission (NRC) data suggests that, in the US alone, there are tens of thousands of high-activity (IAEA Category I and II) sources in thousands of devices; and there are many more tens of thousands of smaller sources scattered among thousands of other NRC licensees. As a result of the ubiquitous nature and undeterminable number of current and legacy sources, even in developed countries they can be abandoned, disposed of in a haphazard manner, lost, stolen, and/or otherwise fallout of regulatory control. Supply and demand of sources, being market based, is more or less fluid. Normative security of radioactive sources exists, but varies in each country, and is loosely implemented through non-legally binding recommendations and standards provided by International Atomic Energy Agency technical documents and cooperation and through bilateral efforts such as this workshop where we share best-practices with one another. Much of the reason for the difficulty in securing sealed sources rests in the enormous need for their beneficial applications in the medical, industrial, and agricultural sectors. Alternative technologies to replace high-risk sources continue to be explored, but very few of these alternative solutions have reached the development stage for common usage and distribution. The beneficial uses of sources must be allowed to continue; however, to minimize the potential for their misuse, current controls and regulating mechanisms must be constantly evaluated to ensure the benefits gained outweigh potential risks. From a global perspective, an evaluation and modification of requirements over the entire life cycle of sources from their manufacture to their final disposition is required. The proper removal and disposal of vulnerable disused or orphan sources is essential to maintaining a safe operating environment. One of our goals in this workshop is to share our methodologies for recovering sources and learn how they differ or are similar to the challenges faced in recovering, storing, and disposing of sources in the Republic of Georgia . The suggestions we will make are flexible in allowing for the imperfect situations and capabilities we have all encountered in source recovery efforts. We have designed a table-top exercise specifically to address your concerns about the prevention and mitigation of contaminated facilities, soil, containers, and sources. Our discussion begins with an overview and video of the OSRP along with a brief on our projects ongoing international cooperation and activities. A presentation will be given by the NRSS illustrating the successes and challenges of source management in Georgia. A brief overview will be given of selected significant cases of the intentional misuse of sources. This will be followed by two comprehensive discussions focusing on the decontamination from the facility perspective down to the issues of container and source leakage. The second day will begin with the abovementioned table-top exercise on contamination control. On the third day, a second presentation from the NRSS will open up the session.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

German experiences in local fatigue monitoring

The ageing management of nuclear power plants (NPP) has gained an increasing importance in the last years. The reasons are mainly due to the international context of extending period of plants operation. Moreover, new scientific discoveries, such as the corrosive influence of the medium on the fatigue process (environmentally assisted fatigue - EAF) play an important role and influence the code development (ASME, EAF code cases). The fatigue damage process takes a central position in ageing mechanisms of components. It must be ensured through appropriate evidence that facilities are being operated under allowable boundary conditions. In the design phase of NPP, fatigue analyses are still based on theoretical considerations and empirical values, which are summarized in the design transient catalogue, necessary for licensing. These analyses aim at proving the admissibility of the loads in terms of stress and fatigue usage. These analyses will also provide the fatigue-relevant positions in the NPP and give a basis for future design improvements and optimization of operating modes. The design transients are in practice conservatively correlated with the real transients occurring during operation. Uncertainties reveal very conservative assumptions regarding forecast temperatures, temperature gradients and frequencies of events. During operation of the plant, it has to be recurrently proved, that the plant is being operated under designed boundary conditions. Moreover, operating signals are constantly acquired to enable a fatigue evaluation. For example, in Germany fatigue evaluation is based on decades of experience and regulatory requirements. The rule KTA 3201.4 [1] establishes the rules for qualified fatigue monitoring. The rule DIN 25475-3 [2] on fatigue monitoring systems is available in draft version. Experience shows that some significant differences occur between the design transients and the real occurred transients during plant operation. The reasons for it are the various manual control options and also different operating modes. It is clear that showing the covering of real loads by design loads, requires a relatively complex and well-qualified detection process. The difficulty of this task is increased due to the lack of data or incomplete information and the exclusive reliance on existing operation plant data. The strategy of employing local fatigue monitoring is a straightforward solution enabling the direct measurement of loads on the fatigue-sensitive zones. Nowadays a direct derivation of the complete stress tensor at the fatigue-relevant locations is enabled thanks to the recorded local loads and combination with finite element (FE) analyses. So, additionally to the recorded temperature curves, a representation of the time evolution of the six stress components for each monitored component is possible. This allows the application of the simplified elasto-plastic fatigue check according to design codes. The fatigue level can be realistically analyzed with a suitable cycle-counting method. Furthermore, the knowledge of the time evolution of the stresses and strains enables to take into account an environmental factor to include the corrosive fluid influence in the calculations. Without local recording, it is impossible to calculate realistic fatigue usage. AREVA offers the AREVA fatigue concept (AFC) and the new fatigue monitoring system integrated (FAMOSi), necessary tools to monitor local fatigue and to provide realistic assessment. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Risks of Hazardous Substances in Radioactive Waste for the Konrad Repository in Germany - 17522

When disposing of radioactive waste with negligible heat generation, the activity of the radionuclides is limited. However, the waste including radioactive material comprises a certain proportion of non-radioactive material. The risk of hazardous contamination of the groundwater by non-radioactive substances must be taken into account. It must be ascertained that the non-radioactive material cannot affect near-surface groundwater, which is a resource for drinking water supply. To achieve this, limit values on the amount of hazardous substances in the total waste volume shall be determined. In 2002 a regulatory approval was granted to the 'Konrad' final storage facility for radioactive waste with negligible heat generation according to the German Water Resources Act. This approval is embedded in the license (plan-approval decision) based on the German Atomic Energy Act. The approval is based on the model of a possible discharge of contaminants from the final storage facility. In a long-term simulation spanning 300,000 years, contact of the waste with the groundwater in the surrounding rock formations over the postoperational phase was conservatively assumed. The maximum amount of allowable disposal of substances - such that no concern of affecting the near-surface groundwater arises - can be derived from the solubility of the respective substances. Implementing the permit according to the Water Resources Act requires: - classification of the waste through delivery declaration obligations - monitoring the substance inspection in the waste to assess its suitability for the disposal, and - stock keeping procedures for the disposal waste by the operator. While the repository is operated by the Federal Office for Radiation Protection (BfS) (http://www.bfs.de./EN/home/home{sub n}ode;), reporting to the Federal Environment Ministry, the statutory water permit is issued and applied by the State of Lower Saxony as responsible state authority. A waste package/container list supplements a comprehensive list of substances. From this - depending on the respectively conditioned waste - material vectors can be derived. For this purpose, BfS provides a database with a substances and container list to the waste owners. In the meantime, first experiences have been collected in applying the approval. More than 540 waste containers with a total mass of almost 6,000 Mg have been controlled and are ready for disposal. In our presentation we will show the recent development in supervising the preparation for the disposal of mixed waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Conceptual Model Update of Mercury Sources and Flux at Y-12 and Upper East Fork Poplar Creek, Oak Ridge,Tennessee

The interactions between the key processes that control the fate and transport of mercury (Hg) in the sediments, groundwater, and stream water within the Y-12 National Security Complex (Y-12) in Oak Ridge, Tennessee are complex, and many aspects are not well understood. In contaminated environments such as Y-12, conceptual models are frequently developed to aid in visualizing and understanding the dynamic nature of the hydrologic, geochemical, and physical environment. These conceptual models integrate data in an internally consistent manner to understand processes that control the fate and transport of contaminants. Over the past few decades of environmental investigation at Y-12, a number of conceptual models have been developed to identify and define various technical processes at various scales. The main purpose of the activities described in this report is to update the 2011 conceptual model for Upper East Fork Poplar Creek using the most recent Hg concentration and flux data and informed scientific interpretation. Emphasis was placed on improving the previous model by implementing a more detailed spatial and temporal approach to visualize transport pathways in the watershed and trends in flux and concentration over time, and to compare baseflow and stormflow system dynamics. Detailed descriptions of historical and current Hg sources and transport pathways are also provided for the east and west ends of the facility. This conceptual model will allow the US Department of Energy to evaluate past and present remedial activities and provide a strong technical basis for prioritizing and optimizing remedial responses in a cost-effective and efficient manner. Twenty years ago, Hg flux from Outfall (OF) 200 at the headwaters of East Fork Poplar Creek represented approximately 20% of the overall flux leaving Y-12. By the time of the 2011 conceptual model report, that percentage had increased to 70%–80%. Flux estimates compiled for this report using data from 2009 to 2018 show that OF200 accounted for roughly 60% of the flux leaving Y-12. The relative role of the four storm drain conduits to OF200 appeared similar to 2011, with OF163 being the greatest contributor to downstream flux. An increase in Hg concentrations and flux occurred throughout and downstream of west end storm drains in 2011 in response to a storm drain cleanout. Leading up to the 2011 storm drain cleanout, annual baseflow flux was higher at OF200A6 than at Station 17. From 2011 to 2018, the trend reversed with concentrations and flux being higher at Station 17 than at OF200A6. A spike in concentrations occurred in July 2018, potentially due to a one-time influx of Hg that occurred during COLEX decontamination and decommissioning activities at Y-12. This report includes recommendations for improving our conceptual understanding of Hg sources, transport pathways, and flux at Y-12. Important recommendations include further evaluation of transport pathways, concurrent measurement of Hg concentration and flux under baseflow and stormflow conditions at multiple sites, and research to understand the connections among periphyton and methylmercury concentration, bioavailability, and bioaccumulation. Ongoing facility decontamination and decommissioning efforts, site characterization, remedial actions, and research are facilitating the collection of new Hg data at Y-12. The conceptual model update provided herein takes advantage of the extensive recent Hg sampling to provide an updated assessment of Hg mass balance and support a refined understanding of Hg behavior at or near Y-12. This assessment should assist in future environmental management decisions and in mitigating the impacts of Hg on the surrounding environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Developments in the Nuclear Safeguards and Security Engineering Degree Program at Tomsk Polytechnic University

Over the last six years, Tomsk Polytechnic University (TPU) has developed a 5½ year engineering degree program in the field of Material Protection Control and Accounting (MPC&A). In 2009 the first students graduated with this new degree. There were 25 job offers from nuclear fuel cycle enterprises of Russia and Kazakhstan for 17 graduates of the program. Due to the rather wide selection of workplaces, all graduates have obtained positions at nuclear enterprises. The program was developed within the Applied Physics and Engineering Department (APED). The laboratory and methodological base has been created taking into consideration the experience of the similar program at the Moscow Engineering Physics Institute (MEPhI). However, the TPU program has some distinguishing features such as the inclusion of special courses pertaining to fuel enrichment and reprocessing. During the last two years, three MPC&A laboratories have been established at APED. This was made possible due to several factors such as establishment of the State innovative educational program at TPU, assistance of the U.S. Department of Energy through Pacific Northwest National Laboratory and Los Alamos National Laboratory, and the financial support of the Swedish Radiation Safety Authority and some Russian private companies. All three of the MPC&A laboratories are part of the Innovative Educational Center “Nuclear Technologies and Non-Proliferation,” which deals with many topics including research activities, development of new curricula for experts training and retraining, and training of master’s students. In 2008, TPU developed a relationship with the International Atomic Energy Agency (IAEA), which was familiarized with APED’s current resources and activities. The IAEA has shown interest in creation of a master’s degree educational program in the field of nuclear security at TPU. A future objective is to acquaint nuclear fuel cycle enterprises with new APED capabilities and involve the enterprises in the scientific and educational projects implemented through the Nuclear Technologies and Non-Proliferation Center. This paper describes the development of the MPC&A engineering degree program and future goals of TPU in the field of nonproliferation education.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Control of Greenhouse Gas Emissions by Optimal DER Technology Investment and Energy Management in Zero-Net-Energy Buildings

The U.S. Department of Energy has launched the commercial building initiative (CBI) in pursuit of its research goal of achieving zero-net-energy commercial buildings (ZNEB), i.e. ones that produce as much energy as they use. Its objective is to make these buildings marketable by 2025 such that they minimize their energy use through cutting-edge, energy-efficiency technologies and meet their remaining energy needs through on-site renewable energy generation. This paper examines how such buildings may be implemented within the context of a cost- or CO2-minimizing microgrid that is able to adopt and operate various technologies: photovoltaic modules (PV) and other on-site generation, heat exchangers, solar thermal collectors, absorption chillers, and passive/demand-response technologies. A mixed-integer linear program (MILP) that has a multi-criteria objective function is used. The objective is minimization of a weighted average of the building's annual energy costs and CO2 emissions. The MILP's constraints ensure energy balance and capacity limits. In addition, constraining the building's energy consumed to equal its energy exports enables us to explore how energy sales and demand-response measures may enable compliance with the ZNEB objective. Using a commercial test site in northernCalifornia with existing tariff rates and technology data, we find that a ZNEB requires ample PV capacity installed to ensure electricity sales during the day. This is complemented by investment in energy-efficient combined heat and power (CHP) equipment, while occasional demand response shaves energy consumption. A large amount of storage is also adopted, which may be impractical. Nevertheless, it shows the nature of the solutions and costs necessary to achieve a ZNEB. Additionally, the ZNEB approach does not necessary lead to zero-carbon (ZC) buildings as is frequently argued. We also show a multi-objective frontier for the CA example, whichallows us to estimate the needed technologies and costs for achieving a ZC building or microgrid.

03 NATURAL GAS↗

Impacts of Antifoam Additions and Argon Bubbling on Defense Waste Processing Facility (DWPF) REDuction/OXidation (REDOX)

Control of the REDuction/OXidation (REDOX) state of glass in High Level Waste (HLW) melters, such as the Defense Waste Processing Facility (DWPF), is critical in order to eliminate the formation of metallic species from overly reduced melts while minimizing foaming from overly oxidized melts. The REDOX control is normally a balance of the oxidants and reductants from the feed and from processing additives. However, after reflux in the Sludge Receipt and Adjustment Tank (SRAT) and the Slurry Mix Evaporator (SME), the balance between the oxidizing salts vs. reducing salts can be altered once the mixture is fed to the melter if the melt pool is bubbled with gaseous species that either oxidize or sparge the melt of oxygen. Hence, for a bubbled melt pool, the REDOX of the melt pool must be targeted based on the balance of the oxidizing and reducing salts from the feed and from the processing additives, as well as, accounting for the effects of any gas being bubbled through the melt to improve convection and mixing while also increasing melt rate. For example, one would not set a REDOX target of Fe 2+ /ΣFe of 0.20 based on chemical balancing and then bubble pure air through the melter as pure air would oxidize the melt pool to an Fe 2+ /ΣFe ~0. Some gases, such as argon, are inert but act as chemical sparging agents or “degassing” agents that can sparge out oxygen from the melt and cause the glass to become more reducing. This study examines DWPF flowsheets at various concentrations of antifoam (a reducing processing additive) in the absence of melt pool bubbling (crucible and production data) and in the presence of melt pool bubbling with argon (crucible and production data), a known sparging/degassing agent. In order to de-convolute the impacts of antifoam on the melt pool REDOX from the impacts of melt pool bubbling, crucible studies were performed with (1) varying antifoam concentrations without bubbling, and (2) minimal antifoam with Ar bubbling. This allowed an antifoam term to be added to the REDOX model and suggested that (1) more oxidizing Fe 2+ /ΣFe ratios could be targeted which would create more oxidizing species in the cold cap to offset the effects of Ar-sparging or (2) Ar-air gas mixtures could be blended with a mixing valve to control the melt pool REDOX at the same Fe 2+ /ΣFe ratios (same –log fO 2 ) as chosen for the chemical REDOX balancing. The 2006 EE REDOX model is an electron equivalents (EE) model that balances the electrons lost during oxidation of a reductant against the electrons gained during the reduction of an oxidant. The EE terms for the formates, nitrates, and oxalates in the REDOX model are based on the formatted salts like NaCOOH, the nitrated salts like NaNO 3 , and the oxalated salts like Na 2 C 2 O 4 that have higher decomposition temperatures than their acidic counterparts which flash off. Thus it is the higher decomposition salts that participate in the establishing the melt REDOX during their interactions in the melter cold cap.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radio Active Waste Plants - Back to the Future

This paper outlines the potential to provide smaller, potentially modular radwaste plants, suitable for new reactor proposals, within increasingly strict environmental control regimes, and with reduced discharge authorisations. Aker Kvaerner have been involved in the design, build and commissioning of radwaste plants over many years and provided the plant for Sizewell B, one of the last major PWRs to be built anywhere in the world. Unit operations and design characteristics of radioactive waste processing plant are discussed. It is concluded that these have changed little in the past 30 years. The traditional build characteristics and metrics of large radioactive waste processing facilities are described in both the reprocessing and the power generation industries. New reactor and fuel characteristics are described and used to highlight areas of potential design improvement, reducing the size, complexity, construction programme and cost of future power reactor radwaste facilities. In summary - implications for Design: Taking these factors into account, we can now expect that compared to Sizewell B radwaste plant, it is possible to match the AP1000 metrics given in Figure 4 above. In principle, this could deliver a building and plant volume of the order of one third to one half of that for Sizewell. It may be possible to make larger reductions in building volume although this is primarily due to the removal of evaporation and relocation of gaseous waste processing. The expected improvements are: - Reduced complexity and interactions significantly improve operational safety - Process intensification and close alignment of processes against reactor waste streams deliver reduced plant size. - Accelerated construction; this becomes possible because of reduced building size, and improved, fit-for-purpose building design. - Programme: The use of skid mounted package plant, modular 'pack' systems for filters and ion exchangers, can shorten construction time. - Allowance for sub contractor support service, by provision of Docking Bays and subcontractor Laydown areas, allows the future use of specialist waste services. - Environmental; Reduced operational source terms gives potential for significantly reduced liquid and gaseous effluent levels. - Solid Waste; improved ion exchange processes deliver equivalent performance with reduced waste volumes. - Increased use of modular design and skid mounted systems. - As a whole, these allow optimal design for the whole life cycle. - Although more intensive, the processes have still not changed from those of the past. Hence, Back to the Future. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Audit Report on "The Department of Energy's American Recovery and Reinvestment Act -- Florida State Energy Program"

The Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE) provides grants to states, territories, and the District of Columbia to support their energy priorities through the State Energy Program (SEP). The SEP provides Federal financial assistance to carry out energy efficiency and renewable energy projects that meet each state's unique energy needs while also addressing national goals such as energy security. Federal funding is based on a grant formula that takes into account population and energy consumption. The SEP emphasizes the state's role as the decision maker and administrator for the program. The American Recovery and Reinvestment Act of 2009 (Recovery Act) expanded the SEP, authorizing $3.1 billion in grants. Based on existing grant formulas and after reviewing state-level plans, EERE made awards to states. The State of Florida's Energy Office (Florida) was allocated $126 million - a 90-fold increase over Florida's average annual SEP grant of $1.4 million. Per the Recovery Act, this funding must be obligated by September 30, 2010, and spent by April 30, 2012. As of March 10, 2010, Florida had expended $13.2 million of the SEP Recovery Act funds. Florida planned to use its grant funds to undertake activities that would preserve and create jobs; save energy; increase renewable energy sources; and, reduce greenhouse gas emissions. To accomplish Recovery Act objectives, states could either fund new or expand existing projects. As a condition of the awards, EERE required states to develop and implement sound internal controls over the use of Recovery Act funds. Based on the significant increase in funding from the Recovery Act, we initiated this review to determine whether Florida had internal controls in place to provide assurance that the goals of the SEP and Recovery Act will be met and accomplished efficiently and effectively. We identified weaknesses in the implementation of SEP Recovery Act projects that have adversely impacted Florida's ability to meet the goals of the SEP and the Recovery Act. Specifically: (1) Florida used about $8.3 million to pay for activities that did not meet the intent of the Recovery Act to create new or save existing jobs. With the approval of the Department, Florida used these funds to pay for rebates related to solar energy projects that had been completed prior to passage of the Recovery Act; (2) State officials did not meet Florida's program goals to obligate all Recovery Act funds by January 1, 2010, thus delaying projects and preventing them from achieving the desired stimulative economic impact. Obligations were delayed because Florida officials selected a number of projects that either required a lengthy review and approval process or were specifically prohibited. In June 2009, the Department notified Florida that a number of projects would not be approved; however, as of April 1, 2010, the State had not acted to name replacement projects or move funds to other projects; (3) Florida officials had not ensured that 7 of the 18 award requirements for Recovery Act funding promulgated by the Department had been passed down to sub-recipients of the award, as required; and, (4) Certain internal control weaknesses that could jeopardize the program and increase the risk of fraud, waste and abuse were identified in the Solar Energy System Incentives Program during our September 2009 visit to Florida. These included a lack of separation of duties related to the processing of rebates and deficiencies in the written procedures for grant managers to review and approve rebates. From a forward looking perspective, absent aggressive corrective action, these weaknesses threaten Florida's efforts to meet future Recovery Act goals. In response to our review, Florida took corrective action to incorporate the additional award requirements in sub-recipient documents. It also instituted additional controls to correct the internal control weaknesses we identified. More, however, needs to be done with respect to Department oversight. This report details the circumstances surrounding these program issues and outlines actions that, in our opinion, will help Florida achieve its SEP Recovery Act-funded goals.

14 SOLAR ENERGY↗

Mercury Reduction and Removal from High Level Waste at the Defense Waste Processing Facility - 12511

The Defense Waste Processing Facility processes legacy nuclear waste generated at the Savannah River Site during production of enriched uranium and plutonium required by the Cold War. The nuclear waste is first treated via a complex sequence of controlled chemical reactions and then vitrified into a borosilicate glass form and poured into stainless steel canisters. Converting the nuclear waste into borosilicate glass is a safe, effective way to reduce the volume of the waste and stabilize the radionuclides. One of the constituents in the nuclear waste is mercury, which is present because it served as a catalyst in the dissolution of uranium-aluminum alloy fuel rods. At high temperatures mercury is corrosive to off-gas equipment, this poses a major challenge to the overall vitrification process in separating mercury from the waste stream prior to feeding the high temperature melter. Mercury is currently removed during the chemical process via formic acid reduction followed by steam stripping, which allows elemental mercury to be evaporated with the water vapor generated during boiling. The vapors are then condensed and sent to a hold tank where mercury coalesces and is recovered in the tank's sump via gravity settling. Next, mercury is transferred from the tank sump to a purification cell where it is washed with water and nitric acid and removed from the facility. Throughout the chemical processing cell, compounds of mercury exist in the sludge, condensate, and off-gas; all of which present unique challenges. Mercury removal from sludge waste being fed to the DWPF melter is required to avoid exhausting it to the environment or any negative impacts to the Melter Off-Gas system. The mercury concentration must be reduced to a level of 0.8 wt% or less before being introduced to the melter. Even though this is being successfully accomplished, the material balances accounting for incoming and collected mercury are not equal. In addition, mercury has not been effectively purified and collected in the Mercury Purification Cell (MPC) since 2008. A significant cleaning campaign aims to bring the MPC back up to facility housekeeping standards. Two significant investigations are being undertaken to restore mercury collection. The SMECT mercury pump has been removed from the tank and will be functionally tested. Also, research is being conducted by the Savannah River National Laboratory to determine the effects of antifoam addition on the behavior of mercury. These path forward items will help us better understand what is occurring in the mercury collection system and ultimately lead to an improved DWPF production rate and mercury recovery rate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Post-closure Nuclear Criticality Safety Evaluations for Disposition of Criticality Control Overpacks at the Waste Isolation Pilot Plant

The Waste Isolation Pilot Plant (WIPP) is a geological repository in southern New Mexico that provides for disposal of transuranic (TRU) wastes from atomic energy defense activities. The Sandia National Laboratories (Sandia) Report, Consideration of Nuclear Criticality When Disposing of Transuranic Waste at the Waste Isolation Pilot Plant, addresses nuclear criticality safety based on the projected inventory characteristics for the initial compliance certification application of WIPP in 1996. As the inventory, waste forms, and disposal package designs change, revised or new analyses are necessary to demonstrate acceptability for these configurations within the WIPP safety basis and compliance with 10,000-year post-closure standards of the US Environmental Protection Agency (EPA). Saylor and Scaglione evaluated criticality control overpacks (CCOs) in 2017 based on conservative assumptions for post-closure repository structural conditions with resulting effects on containers and container spacing, The Saylor and Scaglione evaluation of CCOs addressed a single waste configuration that represents the Surplus Plutonium Disposition Program’s dilute and dispose waste form and composition. This initial CCO study demonstrated that 50 grams of boron carbide (B 4 C) per CCO is sufficient to ensure post-closure criticality safety based on a well-mixed waste composition, and Oak Ridge National Laboratory (ORNL) subsequently determined that this amount of B 4 C does not require constraints on moisture or plastic present as moderator. The Saylor and Scaglione analysis conservatively assumes repository room closure that eliminates all space between fissile gram equivalent (FGE) 239 Pu masses. The close-packed array was selected based on limited availability of repository salt creep modeling results at that time. In 2019, Brickner provided additional evaluations for pipe overpack containers (POCs), building on the conservative basis provided by Saylor and Scaglione. Brickner’s 2019 analysis made use of new geomechanical data for post-closure spacing that rely on advances in repository modeling as documented in the work by Reedlunn and Bean. This current CCO evaluation for generic waste materials expands on earlier work performed at ORNL and includes evaluation of CCOs across a much broader range of possible waste compositions and geometries. This evaluation is intended to provide input for the required feature, event and process (FEP) screening to determine if post-closure criticality must be included as an event in the 10,000-year regulatory evaluation. As such, the approach to modeling post-closure criticality presented in this report has been coordinated with the Sandia team responsible for FEP screening. The resulting analysis supports disposition of fissile materials in the CCO containing up to 380 FGE 239 Pu and expands conditions acceptable for disposal of fissile material in CCOs. This evaluation builds on the methodology of Saylor and Scaglione and Brickner, using the most recently available geomechanical data for CCO spacing under salt creep compaction scenarios provided by Reedlunn and Bean. The broad range of fissile material configurations analyzed in this report are intended to account for configurations that may occur during the post-closure disposal time period, and it also includes waste configurations that are not physically possible to support analysis of conditions that influence neutron fluence.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LLNL Contribution to Sandia Used Fuel Disposition - Security March 2011 Deliverable

Cleary [2007] divides the proliferation pathway into stages: diversion, facility misuse, transportation, transformation, and weapons fabrication. King [2010], using Cleary's methodology, compares a deepburn fusion-driven blanket containing weapons-grade plutonium with a PWR burning MOX fuel enrichments of 5-9%. King considers the stages of theft, transportation, transformation, and nuclear explosive fabrication. In the current study of used fuel storage security, a similar approach is appropriate. First, one must consider the adversary's objective, which can be categorized as on-site radionuclide dispersion, theft of material for later radionuclide dispersion, and theft of material for later processing and fabrication into a nuclear explosive. For on-site radionuclide dispersion, only a single proliferation pathway stage is appropriate: dispersion. That situation will be addressed in future reports. For later radionuclide dispersion, the stages are theft, transportation, and transformation (from oxide spent fuel containing both fission products and actinides to a material size and shape suitable for dispersion). For later processing and fabrication into a nuclear explosive, the stages are theft (by an outsider or by facility misuse by an insider), transportation, transformation (from oxide spent fuel containing both fission products and actinides to a metal alloy), and fabrication (of the alloy into a weapon). It should be noted that the theft and transportation stages are similar, and possibly identical, for later radionuclide dispersion and later processing and fabrication into a nuclear explosive. Each stage can be evaluated separately, and the methodology can vary for each stage. For example, King starts with the methodology of Cleary for the theft, transportation, transformation, and fabrication stages. Then, for each stage, King assembles and modifies the attributes and inputs suggested by Cleary. In the theft (also known as diversion) stage, Cleary has five high-level categories (material handling during diversion, difficulty of evading detection by the accounting system, difficulty of evading detection by the material control system, difficulty of conducting undeclared facility modifications for the purpose of diverting nuclear material, and difficulty of evading detection of the facility modifications for the purposes of diverting nuclear material). Each category has one or more subcategories. For example, the first category includes mass per significant quantity (SQ) of nuclear material, volume/SQ of nuclear material, number of items/SQ, material form (solid, liquid, powder, gas), radiation level in terms of dose, chemical reactivity, heat load, and process temperature. King adds the following two subcategories to that list: SQs available for theft, and interruptions/changes (normal and unexpected) in material stocks and flows. For the situation of an orphaned surface storage facility, this approach is applicable, with some of the categories and subcategories being modified to reflect the static situation (no additions or removals of fuel or containers). In addition, theft would require opening a large overpack and either removing a full container or opening that sealed container and then removing one or more spent nuclear fuel assemblies. These activities would require time without observation (detection), heavy-duty equipment, and some degree of protection of the thieves from radiological dose. In the transportation stage, Cleary has two high-level categories (difficulty of handling material during transportation, and difficulty of evading detection during transport). Each category has a number of subcategories. For the situation of an orphaned surface storage facility, these categories are applicable. The transformation stage of Cleary has three high-level categories (facilities and equipment needed to process diverted materials; knowledge, skills, and workforce needed to process diverted materials; and difficulty of evading detection of transformation activities). Again, there are subcategories. King [2007] adds a fourth high-level category: time required to transform the materials. For the situation of an orphaned surface storage facility, the categories are applicable, but the evaluations of each category and subcategory will be significantly different for later radionuclide dispersion than for later processing and fabrication into a nuclear explosive. The fabrication stage of Cleary has three high-level categories (difficulty associated with design, handling difficulties, and knowledge and skills needed to design and fabricate). King replaces the first two high-level categories with the Figure of Merit for Nuclear Explosives Utility (FOM), with subcategories of bare critical mass, heat content of transformed material, dose rate of transformed material, and SQs available for theft. The next section of this report describes the FOM in more detail.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Grassland Bird Distribution and Raptor Flight Patterns in the Competitive Renewable Energy Zones of the Texas Panhandle [Thesis]

The consistent wind resource in the Great Plains of North America has encouraged the development of wind energy facilities across this region. In the Texas Panhandle, a high quality wind resource is only one factor that has led to the expansion of wind energy development. Other factors include federal tax incentives and the availability of subsidies. Moreover, the State Renewable Portfolio Standards (RPS), mandating production of 10,000 mega-watts of renewable energy in the state by 2025, has contributed to an amicable regulatory and permitting environment (State Energy Conservation Office 2010). Considering the current rate of development, the RPS will be met in coming years (American Wind Energy Association 2011) and the rate of development is likely to continue. To meet increased energy demands in the face of a chronically constrained transmission grid, Texas has developed a comprehensive plan that organizes and prioritizes new transmission systems in high quality wind resource areas called Competitive Renewable Energy Zones (CREZ). The CREZ plan provides developers a solution to transmission constraints and unlocks large areas of undeveloped wind resource areas. In the northern Texas panhandle, there are two CREZs that are classified Class 3 wind (Class 5 is the highest) and range from 862,725 to 1,772,328 ha in size (Public Utility Commission of Texas 2008). Grassland bird populations have declined more than any other bird group in North America (Peterjohn and Sauer 1999, Sauer et al. 2004). Loss of grassland habitat from agricultural development has been the greatest contributor to the decline of grassland bird populations, but development of non-renewable (i.e., oil, coal, and gas) and renewable energy (i.e., wind, solar, biomass, and geothermal) sources have contributed to the decline as well (Pimentel et al. 2002, Maybe and Paul 2007). The effects of wind energy development on declining grassland bird populations has become an area of extensive research, as we attempt to understand and minimize potential impacts of a growing energy sector on declining bird populations. Based on data from post-construction fatality surveys, two grassland bird groups have been the specific focus of research, passerines (songbird guild) and raptors (birds of prey). The effects of wind energy development on these two groups of birds, both of conservation concern, have been examined over the last decade. The primary focus of this research has been on mortality resulting from collision with wind turbines (Kuvlesky et al. 2007). Most studies just quantify post-construction fatality levels (e.g., Erickson et al. 2002) while very few studies provide a comparison of bird populations prior to development through a Before-After-Control-Impact (BACI) study design. Before-After-Control-Impact studies provide powerful evidence of avian/wind energy relationships (Anderson et al. 1999). Despite repeated urgency on conducting these types of studies (Anderson et al. 1999, Madders and Whitfield 2006, Kuvelsky et al. 2007), few have been conducted in North America. Although several European researchers (Larsson 1994, de Lucas et al. 2007) have used BACI designs to examine whether wind facilities modified raptor behavior, there is a scarcity of BACI data relating to North America grassland ecosystems that examine avian-wind energy relationships. There are less than a handful of studies in the entire United States, let alone the southern short grass prairie ecosystem, that incorporate preconstruction data to form the baseline for post-construction impact estimates (Johnson et al. 2000, Erickson et al. 2002). Although declines in grassland bird populations are well-documented (Peterjohn and Sauer 1999, Sauer et al. 2004), the causal mechanisms affecting the decline of grassland birds with increasing wind energy development in the southern short grass prairie are not well-understood (Kuvlesky et al. 2007, Maybe and Paul 2007). Several factors may potentially affect the bird population when wind turbines are constructed in areas with high bird densities (de Lucas et al. 2007). Habitat fragmentation, noise from turbines, physical movement of turbine blades, and increased vehicle traffic have been suggested as causes of decreased density of nesting grassland birds in Minnesota (Leddy et al. 1999), Oklahoma (O’Connell and Piorkowski 2006), and South Dakota (Shaffer and Johnson 2008). Similarly, constructing turbines in areas where bird flight patterns place them at similar heights of turbine blades increases the potential for bird collisions (Johnson et al. 2000, Hoover 2002). Raptor fatalities have been associated with topographic features such as ridges, saddles and rims where birds use updrafts from prevailing winds (Erickson et al. 2000, Johnson et al. 2000, Barrios and Rodriquez 2004, Hoover and Morrison 2005). Thus, wind energy development can result in indirect (e.g., habitat avoidance, decreased nest success) and direct (e.g., collision fatalities) impacts to bird populations (Anderson et al. 1999). Directly quantifying the level of potential impacts (e.g., estimated fatalities/mega-watthour) from wind energy development is beyond the scope of this study. Instead, I aim to quantify density, occupancy and flight behavior for the two bird groups mentioned earlier: obligate grassland songbirds and raptors, respectively, predict where impacts may occur, and provide management recommendations to minimize potential impacts. The United States Department of Energy (DOE), through the Office of Energy Efficiency and Renewable Energy Allocation, contracted Texas Tech University to investigate grassland bird patterns of occurrence in the anticipated CREZ in support of DOE’s 20% Wind Energy by 2030 initiative. In cooperation with Iberdrola Renewables, Inc., studies initiated by Wulff (2010) at Texas Tech University were continued at an area proposed for wind energy development and a separate reference site unassociated with wind energy development. I focused on four primary objectives and this thesis is accordingly organized in four separate chapters that address grassland bird density, grassland bird occupancy, raptor flight patterns, and finally I summarize species diversity and composition. The following chapters use formatting from the Journal of Wildlife Management guidelines (Block et al. 2011) with modifications as required by the Texas Tech University Graduate School. 1) I estimate pre-construction bird density patterns using methods that adjust for imperfect detection. I used a distance sampling protocol that effectively accounts for incomplete detection in the field where birds are present but not detected (Buckland et al. 2001). I improved density estimates with hierarchical distance sampling models, a modeling technique that effectively incorporates the detection process with environmental covariates that further influence bird density (Royle et al. 2004, Royle and Dorazio 2008). Covariates included road density and current oil and gas infrastructure to determine the relationship between existing energy development and bird density patterns. Further, I used remote sensing techniques and vegetation field data to investigate how landcover characteristics influenced bird density patterns. I focused species-specific analyses on obligate grassland birds with >70 detections per season namely grasshopper sparrow (Ammodramus savannarum) and horned lark (Eremophila alpestris). Chapter II focuses on hierarchical models that model and describe relationships between grassland bird density and anthropogenic and landscape features. 2) A large number of bird detections (>70) are needed to estimate density using distance sampling and collection of such quantity are often not feasible, particularly for cryptic species or species that naturally occur at low densities (Buckland et al. 2001). Occupancy models operate with far fewer data and are often used as a surrogate for bird abundance when there are fewer detections (MacKenzie and Nichols 2004). I used occupancy models that allow for the possibility of imperfect detection and species abundance to improve estimates of occurrence probability (Royal 2004). I focused species-specific analyses on grassland birds with few detections: Cassin’s sparrow (Peucaea cassinii), eastern meadowlark (Sturnella magna), and upland sandpiper (Bartramia longicauda). Chapter III uses a multi-season dynamic site occupancy model that incorporates bird abundance to better estimate occurrence probability. 3) When I considered the topographic relief of the study sites, the proposed design of the wind facility and its location within the central U.S. migratory corridor, I expanded the study to investigate raptor abundance and flight behavior (Hoover 2002, Miller 2008). I developed a new survey technique that improved the accuracy of raptor flight height estimates and compared seasonal counts and flight heights at the plateau rim and areas further inland. I used counts and flight behaviors to calculate species-specific collision risk indices for raptors based on topographic features. I focused species-specific analyses on raptors with the highest counts: American kestrel (Falco sparverius), northern harrier (Circus cyaneus), red-tailed hawk (Buteo jamaicensis), Swainson’s hawk (Buteo swainsoni), and turkey vulture (Cathartes aura). Chapter IV describes patterns of seasonal raptor abundance and flight behavior and how topography modulates collision risk with proposed wind energy turbines. 4) Finally, for completeness, in Chapter V I summarize morning point count data for all species and provide estimates of relative composition and species diversity with the Shannon-Wiener Diversity Index (Shannon and Weaver 1949).

17 WIND ENERGY↗

Effects of Mineral Impurities and Heat on Uranium(VI) Sorption onto Bentonite (Final Report)

Most nuclear waste disposal options include compacted bentonite, consisting of montmorillonite clay, as part of a barrier system to minimize contaminant mobility. Uranium (U) is the primary element in spent nuclear fuel, and from an environmental perspective, a potential contaminant of water resources. Furthermore, uranium may control nuclear fuel degradation rates and the consequent release of other radioactive contaminants based on its diffusive transport away from waste canisters. Uranium sorption onto clay and other mineral surfaces is expected to limit U(VI) mobility in these systems. However, at this point a prediction of U(VI) sorption and transport behavior in performance assessment (PA) models is complicated by a series of factors, such as: (1) the presence of various U(VI) solution species with different charges and sorption characteristics; (2) the complex microstructure of montmorillonite clay resulting in two types of clay porosities and multiple sorption sites; (3) the largely unknown effects of bentonite mineral impurities on pore water chemistry, U(VI) sorption and diffusion behavior; and (4) the potential impacts of heat, generated by the decay of spent fuel, on mineralogical and microstructural transformations, and any subsequent effects on radionuclide sorption and mobility. In this project, we investigated the effects of calcite impurities on U(VI) sorption and diffusion onto montmorillonite before and after mineral exposure to heat. Overall, our main goals were to: 1. Gain a mechanistic understanding of the effects of calcite impurities on U(VI) sorption and diffusion in montmorillonite/bentonite at variable chemical conditions, and before and after mineral exposure to heat; and to 2. Work towards the development of new surface complexation and diffusion models to predict U(VI) sorption and mobility in montmorillonite/bentonite while accounting for the impacts of calcite impurities and heat. In order to achieve these goals, we pursued the following research objectives and tasks: 1. Characterize the effects of calcite impurities on U(VI) sorption onto Na-montmorillonite, and evaluate if and how these effects change due to solids’ exposure to heat (Task 1). 2. Characterize U(VI) surface speciation in solid samples from Task 1, with a particular focus on U(VI) precipitates and co-precipitates (Task 2). 3. Test the relevance of observed changes in U(VI) sorption characteristics for U(VI) diffusive transport behavior in bentonite barriers (Task 3). 4. Evaluate the exclusion of anionic U(VI) solution complexes from clay nanopores (Task 4). 5. Building on Tasks 1-4, start the development of new surface complexation and reactive transport models that can simulate and predict U(VI) sorption and diffusion in complex bentonite systems (Task 5). A detailed description of all tasks, and their specific results and conclusions is provided in this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Synthesis of Post-fire Monitoring Activities in the Great Basin Desert, Mojave Desert, and Transition Zones

In the deserts of the American Southwest, fire return intervals of centuries to millennia are being replaced by fire return intervals of decades. This increased burn frequency has implications for post-closure management and long-term stewardship for Soils Corrective Action Units (CAUs) and Corrective Action Sites (CASs) on the Nevada National Security Site (NNSS), Tonopah Test Range, and Nevada Test and Training Range for which the U.S. Department of Energy (DOE), Environmental Management-Nevada (EM-NV) is responsible. For many CAUs and CASs, where closure-in-place alternatives were implemented or are being considered, there is a chance that these sites could burn over while they still pose a risk to the environment or human health given the long half-lives of some of the radionuclide contaminants of concern (COCs) (Shafer et al., 2007; Shafer and Gomes, 2009). Although it would have been ideal to conduct a fire-related study at a radionuclide contaminated site on the NNSS to determine how contaminated soils are transported post-fire, it was more practical to examine fires in environments analogous to where Soils Activity CAUs and CASs exist. Therefore, a series of studies were initiated at three radiologically uncontaminated analog sites to better understand the possible effects of wildfire on erosion and sediment transport by wind and water should vegetation at contaminated sites burn at the NNSS. The studies took place at the sites of the Gleason Fire, a prescribed burn that occurred near Ely, Nevada, which is in the Great Basin ecoregion; the White Rock Fire that occurred near Mesquite, Nevada, which is in the Mojave Desert ecoregion; and the Jacob Fire that occurred near Hiko, Nevada, in the transitional zone between the Great Basin Desert and the Mojave Desert. Each site was representative of one of the three ecoregions found on the NNSS. Erosion and vegetation characteristics were measured multiple times post-fire on both burned and unburned test plots at these study sites to compare and monitor the effects of fire over time. However, at the Mojave Desert site, there was an additional burn from nearly 25 years ago that was also compared with the more recent burned areas from 2013. Also, the time elapsed after the fire and the time when sampling began differed among the ecoregions. For example, at the Great Basin site, samples were collected prior to the fire and less than one month after the fire, whereas data collected at the Mojave Desert site did not occur until 22 months after the fire. The differences between the sample measurements and the time that elapsed after the fire may contribute to the variability in the data and the interpretations of the data. Runoff and water erosion were quantified through a series of rainfall and runoff simulation tests in which controlled amounts of water were delivered to the soil surface. Runoff data were collected from different microhabitats (e.g., undercanopies, interspace soils, ridges, and drainage areas). The data showed soil hydrophobicity (i.e., water repellency) on the Great Basin site for up to 12 months after the fire. The soil structure remained changed and weaker on the burned areas compared with the unburned areas for the three-year study period. Although runoff data at both the Great Basin site and transition zone site were highly variable, the post-fire runoff potential did not generally increase at either location after three years of monitoring. Mojave runoff did not differ much between fire ages or between burned and unburned areas, possibly because of the amount of vegetation growing on all three surfaces and because the fire intensity was likely lower relative to other ecoregions due to the amount of space between plants. Additionally, the measurements conducted on the Mojave fire occurred several years after the fire had burned and not within several months of the burn, which may also account for the lack of differences in runoff between burned and unburned locations. Wind erosion was assessed and quantified with a Portable In-Situ Wind ERosion Lab (PI-SWERL) on both the burned and unburned soils of different microhabitats (e.g., ridges, drainages, interspaces between plants, and plant undercanopies). Estimates of emissions (e.g., particulate matter with aerodynamic diameters less than or equal to 10 micrometers, or PM10) at different wind speeds were collected and filter samples were analyzed for chemical composition. The measurements among the fires were similar and the results of the wind erosion measurements indicate that there were seasonal influences on many parameters, but the potential for PM10 windblown dust emissions was higher on burned areas compared with unburned areas. Among the burned areas, drainages produced the most dust emissions, whereas burned ridges were the least emissive. Emissions at the Mojave site and transition zone site were similar between burned and unburned areas approximately three years after the respective fires. Emissions remained much greater on burned soils at the Great Basin site. However, site selection may have also contributed to the differences of emissions among the three study locations. Post-fire vegetation responses were documented for three years following each fire in different microhabitats (e.g., ridge, drainage, undercanopy, and interspace) at the Great Basin and transition zone sites. In 2013, at the Mojave fire site, random permanent plots were established in newly burned areas, areas that burned approximately 25 years ago, and an unburned control area. At each fire site, the regeneration of native plant species dominated the burned areas, but invasive annual grasses were present at each fire site. During the course of each three-year study, the invasive annual grasses increased in density or percentage at both the Great Basin and transition fire sites but not at the Mojave site, where annual invasive grasses remained high throughout the study period. However, the chronosequence data from the Mojave site indicate a transition to different invasive grass species with time. The post-burn vegetation at all three ecoregions is still in the early stages of succession, and shrub size should increase over time and shrub density should decrease over time. However, the recovery of the plant communities to pre-burn compositions may not occur for decades or centuries, or may not occur because of changes in climate and the presence of invasive annual grasses. Results from the three study locations suggested that contaminated soils on the NNSS that experienced wildfire had the potential for soil erosion and transport of contaminated soils. Both wind and soil runoff studies indicated that locations in the Great Basin and transition zone ecoregions were more susceptible to erosion than the Mojave Desert ecoregion, but the highest levels of erosion occurred during the early portions of the study (the first 24 months) and the Mojave Desert was not measured until 22 months after the burn. Additionally, data from the Great Basin indicated deeper soils may increase susceptibility to wind erosion. Historically, the Great Basin and transition zone ecoregions burned more frequently than the Mojave Desert because of fuel abundance and connectivity—and they continue to burn more frequently, particularly after the introduction of invasive grasses (Davies and Nafus, 2013). However, both ecoregions and the transition zone have burned with extensive, high-severity fires when certain weather and fuel conditions are met. For example, the high abundance and productivity of annual grasses and forbs—which are usually produced by above average winter precipitation—combined with early spring and summer warm, dry conditions. Future climate scenarios predict increased temperatures, variable to reduced precipitation, and larger, more extreme wildfires throughout western North America. These predictions suggest that future fires on the NNSS could increase in frequency, intensity, and severity similar to their analog ecosystems throughout the Great Basin and Mojave Desert (Dennison et al., 2014; Abatzoglou andWilliams, 2016; Westerling, 2016).

54 ENVIRONMENTAL SCIENCES↗

F-Tank Farm Performance Assessment Updates through the Special Analysis Process at Savannah River Site - 12169

The F-Area Tank Farm (FTF) is owned by the U.S. Department of Energy and operated by Savannah River Remediation, LLC (SRR), Liquid Waste Operations contractor at DOE's Savannah River Site (SRS). The FTF is in the north-central portion of the SRS and occupies approximately 22 acres within F-Area. The FTF is an active radioactive waste storage facility consisting of 22 carbon steel waste tanks and ancillary equipment such as transfer lines, evaporators and pump tanks. An FTF Performance Assessment (PA) was prepared to support the eventual closure of the FTF underground radioactive waste tanks and ancillary equipment. The PA provides the technical basis and results to be used in subsequent documents to demonstrate compliance with the pertinent requirements identified below for final closure of FTF. The FTank Farm is subject to a state industrial waste water permit and Federal Facility Agreement. Closure documentation will include an F-Tank Farm Closure Plan and tank-specific closure modules utilizing information from the performance assessment. For this reason, the State of South Carolina and the Environmental Protection Agency must be involved in the performance assessment review process. The residual material remaining after tank cleaning is also subject to reclassification prior to closure via a waste determination pursuant to Section 3116 of the Ronald W. Reagan National Defense Authorization Act of Fiscal Year 2005. The projected waste tank inventories in the FTF PA provide reasonably bounding FTF inventory projections while taking into account uncertainties in the effectiveness of future tank cleaning technologies. As waste is removed from the FTF waste tanks, the residual contaminants will be sampled and the remaining residual inventory is characterized. In this manner, tank specific data for the tank inventories at closure will be available to supplement the waste tank inventory projections currently used in the FTF PA. For FTF, the new tank specific data will be evaluated through the Special Analysis process. The FTF Special Analyses process will be utilized to evaluate information regarding the final residual waste that will be grouted in place in the FTF Tanks and assess the potential impact the new inventory information has on the FTF PA assumptions and results. The Special Analysis can then be used to inform decisions regarding FTF tank closure documents. The purpose of this paper is to discuss the Special Analysis process and share insights gained while implementing this process. An example of an area of interest in the revision process is balancing continuous improvement versus configuration control of agreed upon methodologies. Other subjects to be covered include: 1) defining the scope of the revisions included in the Special Analysis, 2) determining which PA results should be addressed in the Special Analysis, and 3) deciding whether the Special Analysis should utilize more qualitative or quantitative assessments. For the SRS FTF, an FTF PA has been prepared to provide the technical basis and results to be used in subsequent documents to demonstrate compliance with the pertinent requirements for final closure of FTF. The FTF Special Analyses process will be utilized to evaluate the impact new information has on the FTF PA assumptions and results. The Special Analysis can then be used to inform decisions regarding FTF tank closure documents. In preparing SAs, it is crucial that the scope of the SA be well defined within the SA, since the specific scope will vary from SA to SA. Since the SAs are essentially addendums to the PA, the SA scope should utilize the PA as the baseline from which the SA scope is defined. The SA needs to focus on evaluating the change associated with the scope, and not let other changes interfere with the ability to perform that evaluation by masking the impact of the change. In preparing the SA, it is also important to let the scope determine whether the Special Analysis should utilize more qualitative or quantitative assessments and also which results from the PA should be addressed in the Special Analysis. These decisions can vary from SA and should not be predetermined. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗