Search NASA⌕ Search

SEARCH · Search NASA

Results for “Current Controllers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Advanced Electric Distribution, Switching, and Conversion Technology for Power Control

The Electrical Power Control Unit currently under development by Sundstrand Aerospace for use on the Fluids Combustion Facility of the International Space Station is the precursor of modular power distribution and conversion concepts for future spacecraft and aircraft applications. This unit combines modular current-limiting flexible remote power controllers and paralleled power converters into one package. Each unit includes three 1-kW, current-limiting power converter modules designed for a variable-ratio load sharing capability. The flexible remote power controllers can be used in parallel to match load requirements and can be programmed for an initial ON or OFF state on powerup. The unit contains an integral cold plate. The modularity and hybridization of the Electrical Power Control Unit sets the course for future spacecraft electrical power systems, both large and small. In such systems, the basic hybridized converter and flexible remote power controller building blocks could be configured to match power distribution and conversion capabilities to load requirements. In addition, the flexible remote power controllers could be configured in assemblies to feed multiple individual loads and could be used in parallel to meet the specific current requirements of each of those loads. Ultimately, the Electrical Power Control Unit design concept could evolve to a common switch module hybrid, or family of hybrids, for both converter and switchgear applications. By assembling hybrids of a common current rating and voltage class in parallel, researchers could readily adapt these units for multiple applications. The Electrical Power Control Unit concept has the potential to be scaled to larger and smaller ratings for both small and large spacecraft and for aircraft where high-power density, remote power controllers or power converters are required and a common replacement part is desired for multiples of a base current rating.

Soltis, James V.↗

Influence of Control and Limiter Schemes on Sequence-Domain Fault Models of Grid-Forming Inverter-Interfaced Distributed Generators

Unlike synchronous generators, the fault response of grid-forming (GFM) inverter-interfaced distributed generators (IIDGs) is notably governed by the selection of control and current limiting strategies rather than inherent physical traits. While recent research has focused on the sequence domain fault model of GFM IIDGs, a research gap exists in elucidating the influence of control and current limiting schemes on this model's characteristics. This article aims to fill this void by examining how different control and current limiting schemes influence the positive and negative sequence impedances in the phasor-domain fault model of GFM IIDGs. This investigation encompasses droop-based, virtual synchronous machine-based, and virtual oscillator-based reference generation controls alongside rotating and stationary reference-frame-based voltage controls. Furthermore, saturation-based, latching-based, circular and virtual impedance-based current limiting schemes are analyzed. To achieve this goal, a thorough numerical simulation study is conducted. Findings indicate that outer reference generation controls exhibit minimal impact. Conversely, the choice of voltage control and various current limiting schemes emerge as the predominant factors shaping the sequence models of GFM IIDGs. These analyses and results are instrumental in devising reliable protection strategies within inverter-based grids, as a comprehensive understanding of electrical elements in the sequence domain is imperative for effective protective measures.

current limiters↗

Hepatitis C virus NS3/4A inhibitors and other drug-like compounds as covalent binders of SARS-CoV-2 main protease

Severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2), which causes coronavirus disease 2019 (COVID-19), threatens global public health. The world needs rapid development of new antivirals and vaccines to control the current pandemic and to control the spread of the variants. Among the proteins synthesized by the SARS-CoV-2 genome, main protease (M pro also known as 3CL pro ) is a primary drug target, due to its essential role in maturation of the viral polyproteins. In this study, we provide crystallographic evidence, along with some binding assay data, that three clinically approved anti hepatitis C virus drugs and two other drug-like compounds covalently bind to the M pro Cys145 catalytic residue in the active site. Also, molecular docking studies can provide additional insight for the design of new antiviral inhibitors for SARS-CoV-2 using these drugs as lead compounds. One might consider derivatives of these lead compounds with higher affinity to the M pro as potential COVID-19 therapeutics for further testing and possibly clinical trials.

36 MATERIALS SCIENCE↗

SEMI-ACTIVE CONTROL FOR TWO-BODY OCEAN WAVE ENERGY CONVERTER BY USING HYBRID MODEL PREDICTIVE CONTROL

Model predictive control (MPC) has been considered as one important feed-forward optimal control strategy for ocean wave energy converter (WEC) targeted on power maximization. The capability of MPC to handle system constraints (ex. stroke, velocity, actuator limitations), and the availability to provide optimal solution for linear system provide potential for the implementation of such algorithm in the WEC control. However, currently, only active MPC control has been introduced for single and two-body WECs. Such control strategy may introduce negative power during the optimization process, since the power take-off (PTO) damping has no constraint. In this paper, we proposed a hybrid MPC strategy in limiting both the PTO damping force and PTO damping to avoid negative power generation during cost function minimization (negative power minimization) for the two-body WEC. The problem is formulated into a quadratic programming (QP) problem targeted at power maximization. However, the standard QP problem formulation cannot be directly applied to the semi-active control problem due to the PTO damping constraints. Therefore, the problem is reformulated as a Mixed-integer Quadratic Programming (MIQP) problem, which contains logical switch to select constraint matrices based on the sign of the relative velocity between the buoy and submerged body. The optimal solution is compared with those of the active MPC control strategy and the passive model with the same irregular wave input.

16 TIDAL AND WAVE POWER↗

XAFS Investigation of Nanoparticle Formation in {sup 64}Zn{sup +} Ion Implanted and Thermo Oxidized Si

The single crystal CZ n-Si(100) substrates with electron concentration n{sub o} = 5 × 10{sup 16} cm{sup −3} were implanted by {sup 64}Zn{sup +} ions with dose of 5 × 10{sup 16} cm{sup −2} and energy of 50 keV. During implantation the ion beam current density was less than 0.5 μA/cm{sup 2} to avoid the substrate magnetically heating. After implantation, the plates were subjected to isochronous for one hour heat treatment in oxygen atmosphere at temperatures from 400 up to 1000{sup o}C with a step of 100{sup o}C. Zn K-edge EXAFS spectra were measured in fluorescent mode. Si(111) channel-cut monochromator was used for energy scanning; energy resolution ΔE/E = 2 × 10{sup –4}. According to Zn K-edge EXAFS data, all Zn implanted in Si at 900{sup o}C is fully oxidized: an absolute maximum of EXAFS Fourier transform at R ~ 1.6 Å corresponds to Zn–O distance. Based on XANES data, we suggest an interaction between implanted Zn atoms and Si support.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Technologies for providing secure emergency power control of high voltage direct current transmission system

Technologies for providing secure emergency power control of a high voltage direct current transmission (HVDC) system include a controller. The controller includes circuitry configured to receive status data indicative of a present physical status of a power system. The circuitry is also configured to obtain an emergency power control command triggered by a remote source. The emergency power control command is to be executed by an HVDC transmission system of the power system. Further, the circuitry is configured to determine, as a function of the status data, whether the emergency power control command is consistent with the present physical status of the power system and block, in response to a determination that the emergency power control command is not consistent with the present physical status of the power system, execution of the emergency power control command by the HVDC transmission system.

Pan, Jiuping↗

Enabling Grid-Forming Control Under Unbalanced Conditions

Standalone microgrids often experience unbalanced loading and faults, which can cause grid-forming control designed for balanced conditions to produce oscillatory responses. To address this issue, a compact time-domain transformation appropriate for inverter control is proposed, allowing the conversion of unbalanced three-phase signals to positive and negative synchronous reference frames. This transformation supports the development of a grid-forming control with fault ride-through, featuring frequency and voltage droop controllers and nested current and voltage control loops that seamlessly integrate an enhanced current limiter. The effectiveness of the proposed control and transformation is demonstrated through analytical results and electromagnetic transient simulation.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Actuation of Deformable Mirrors Using Laser Controlled Pistons

Current deformable mirrors used for adaptive optics employ many actuators to adjust the mirror in order to compensate for optical irregularities. These mechanical actuators, which can number in the hundreds for a given mirror, require a significant amount of electrical wires in order to be controlled. The objective of this research is to implement a different type of actuator that can be controlled without the use of wires. The actuator developed employs a laser to quickly heat and expand the air in a closed "cell." When the air expands, it pushes a membrane that causes the mirror to move. Creating an array of these cells, and scanning them with a laser can control a deformable mirror. Testing showed that a single cell with a 5-mm diameter and 10-mm length can deflect a membrane of aluminized mylar in excess of our minimum requirement of 20 microns. These cells can now be assembled in a 5x5 matrix and attached to many small Mirrors. An electro-mechanical scanning assembly can be used to aim the laser directly onto individual cells causing the mirror at that location to move.

Scott, Charles E.↗

Actuation of Deformable Mirrors Using Laser Controlled Pistons

Current deformable mirrors used for adaptive optics employ many actuators to adjust the mirror in order to compensate for optical irregularities. These mechanical actuators, which can number in the hundreds for a given mirror, require a significant amount of electrical wires in order to be controlled. The objective of this research is to implement a different type of actuator that can be controlled without the use of wires. The actuator developed employs a laser to quickly heat and expand the air in a closed 'cell'. When the air expands, it pushes a membrane that causes the mirror to move. Creating an array of these cells, and scanning them with a laser can control a deformable mirror. Testing showed that a single cell with a 5 mm diameter and 10 mm in length can deflect a membrane of aluminized Mylar in excess of our minimum requirement of 20 microns. These cells can now be assembled in a 5 x 5 matrix and attached to many small mirrors. An electro-mechanical scanning assembly can be used to aim the laser directly onto individual cells causing the mirror at that location to move.

deformable mirrors↗

Supercritical CO2 Cleaning System for Planetary Protection and Contamination Control Applications

Current spacecraft-compatible cleaning protocols involve a vapor degreaser, liquid sonication, and alcohol wiping. These methods are not very effective in removing live and dead microbes from spacecraft piece parts of slightly complicated geometry, such as tubing and loosely fitted nuts and bolts. Contamination control practices are traditionally focused on cleaning and monitoring of particulate and oily residual. Vapor degreaser and outgassing bakeout have not been proven to be effective in removing some less volatile, hydrophilic biomolecules of significant relevance to life detection. A precision cleaning technology was developed using supercritical CO2 (SCC). SCC is used as both solvent and carrier for removing organic and particulate contaminants. Supercritical fluid, like SCC, is characterized by physical and thermal properties that are between those of the pure liquid and gas phases. The fluid density is a function of the temperature and pressure. Its solvating power can be adjusted by changing the pressure or temperature, or adding a secondary solvent such as alcohol or water. Unlike a regular organic solvent, SCC has higher diffusivities, lower viscosity, and lower surface tension. It readily penetrates porous and fibrous solids and can reach hard-to-reach surfaces of the parts with complex geometry. Importantly, the CO2 solvent does not leave any residue. The results using this new cleaning device demonstrated that both supercritical CO2 with 5% water as a co-solvent can achieve cleanliness levels of 0.01 mg/cm2 or less for contaminants of a wide range of hydrophobicities. Experiments under the same conditions using compressed Martian air mix, which consists of 95% CO2, produced similar cleaning effectiveness on the hydrophobic compounds. The main components of the SCC cleaning system are a high-pressure cleaning vessel, a boil-off vessel located downstream from the cleaning vessel, a syringe-type high-pressure pump, a heat exchanger, and a back pressure regulator (BPR). After soaking the parts to be cleaned in the clean vessel for a period, the CO2 with contaminants is flushed out of the cleaning vessel using fresh CO2 in a first-in-first-out (FIFO) method. The contaminants are either precipitating out in the boil-off container or being trapped in a filter subsystem. The parts to be cleaned are secured in a basket inside and can be rotated up to 1,400 rpm by a magnetic drive. The fluid flows within the vessel generate tangential forces on the parts surfaces, enhancing the cleaning effectiveness and shortening the soaking time. During the FIFO flushing, the pump subsystem pushes fresh CO2 into the cleaning vessel at a constant flow rate between 0.01 and 200 mL/min, while the BPR regulates the pressure in the cleaning vessel to within 0.1 bar by controlling the needle position in an outlet valve. The fresh CO2 gas flows through the heat exchanger at a given temperature before entering the cleaning vessel. A platinum resistance thermometer (PRT) reads the cleaning vessel interior temperature that can be controlled to within 0.1 K. As a result, cleaning vessel temperature remains constant during the FIFO flushing. There is no change in solvent power during FIFO flushing since both temperature and pressure inside the cleaning vessel remain unchanged, thus minimizing contaminants left behind. During decompression, both temperature and pressure are strictly controlled to prevent bubbles from generating in the cleaning vessel that could stir up the contaminants that sank to the bottom by gravity.

Lin, Ying↗

Frequency Response Improvement in a Standalone Small Hydropower Plant Using Battery Storage

This paper proposes a control architecture for frequency, current, and voltage control that facilitates using battery storage to improve the response of standalone small hydropower plants. The frequency controller uses rate-of-change of frequency and frequency-Watt-based generations to produce active power commands. The distinctive feature of the controller design is that it nicely integrates response to frequency change with constraints on frequency and state of battery to enable power injections. The current and voltage control scheme allows incorporating the frequency controller. The distinctive feature of this controller is that it incorporates a bounded integral control strategy that guarantees stability. Results on the stability of the hydropower plant with proposed scheme are presented and robust ways to choose the controller gains are investigated via root locus analysis. In conclusion, simulations performed show that: the hydropower plant response is significantly improved with battery storage using the proposed scheme; the load carrying capability of the hydropower plant is significantly improved with battery storage; the proposed scheme has the capability to recharge the battery; and the proposed control scheme gives improved performance.

13 HYDRO ENERGY↗

Current Level of Mission Control Automation at NASA/Goddard Space Flight Center

NASA is particularly concerned with reducing mission operations costs through increased automation. This paper examines the operations procedures within NASA Mission Control Centers in order to uncover the level of automation that currently exists within them. Based on an assessment of mission operations procedures within three representative control centers, this paper recommends specific areas where there is potential for mission cost reduction through increased automation.

Maks, Lori↗

Investigation of electrodynamic stabilization and control of long orbiting tethers

An algorithm for using electric currents to control pendular oscillations induced by various perturbing forces on the Skyhook wire is considered. Transverse and vertical forces on the tether; tether instability modes and causes during retrieval by space shuttle; simple and spherical pendulum motion and vector damping; and current generation and control are discussed. A computer program for numerical integration of the in-plane and out-of-plane displacements of the tether vs time was developed for heuristic study. Some techniques for controlling instabilities during payload retrieval and methods for employing the tether for launching satellites from the space shuttle are considered. Derivations and analyses of a general nature used in all of the areas studied are included.

Arnold, D. A.↗

Probabilistic Parameter Uncertainty Analysis of Single Input Single Output Control Systems

The current standards for handling uncertainty in control systems use interval bounds for definition of the uncertain parameters. This approach gives no information about the likelihood of system performance, but simply gives the response bounds. When used in design, current methods of m-analysis and can lead to overly conservative controller design. With these methods, worst case conditions are weighted equally with the most likely conditions. This research explores a unique approach for probabilistic analysis of control systems. Current reliability methods are examined showing the strong areas of each in handling probability. A hybrid method is developed using these reliability tools for efficiently propagating probabilistic uncertainty through classical control analysis problems. The method developed is applied to classical response analysis as well as analysis methods that explore the effects of the uncertain parameters on stability and performance metrics. The benefits of using this hybrid approach for calculating the mean and variance of responses cumulative distribution functions are shown. Results of the probabilistic analysis of a missile pitch control system, and a non-collocated mass spring system, show the added information provided by this hybrid analysis.

Smith, Brett A.↗

Current Observer Based Predictive Decoupled Power Control Grid-Interactive Inverter

This paper presents a sensor-less current model predictive control (MPC) scheme via a full state observer based current estimator. The grid interactive inverters’ control schemes require current and voltage sensors. Elimination of current sensor enhances the inverter reliability. This paper leverages the inherent characteristics of MPC towards robust current sensor-less grid interactive inverter with LC filter. The observer for inductor current is developed based on the existing capacitor voltage measurement. The estimator dynamic state-space matrices are then obtained through reconstruction of the inverter model with the capacitor voltage and inductor current being the state variables. The controller objectives are to regulate active and reactive power in a decoupled manner. The theoretical expectation, controller performance, and accuracy of the current estimation are verified by conducting a real-time simulation via Typhoon HIL.

Zhang, Zhen↗

Results and lessons learned from accelerating radio frequency modeling using machine learning [slides]

The “advanced tokamak” reactor concept is a leading candidate for a steady state fusion pilot plant. An advanced tokamak (AT) sustains a majority of the required plasma current with effects resulting from maintenance of the peaked pressure at the device center. This current is augmented by auxiliary current drive sources. These auxiliary actuators may consist of neutral particle beams and/or radio frequency (RF) systems such as lower hybrid current drive (LHCD) and high harmonic fast wave (HHFW) current drive using radio and microwaves from antennas. The primary focus of this work is to develop models of RF current profile control suitable for use in integrated modeling frameworks and for real-time control in experiments. Direct physics models of RF current drive can be computationally intensive. In order to achieve predictive times appropriate for the thousands of calls needed in real-time control of experiments and for use in integrated models, we will apply modern machine learning (ML) techniques to accelerate these models and interpolate their results. To generate the fast and accurate models for use in control level algorithms and integrated modeling we need to replace present models with high dimensional interpolation of their results. We will perform additional simulations across a broader parameter range for EAST and other tokamaks in different physics regimes (Alcator C-Mod, DIII-D, WEST, CFETR, ARC, ITER) and combine them into a larger database for training and testing of the ML models. Further testing of the control level models with experimental current profile data from EAST and C-Mod tokamaks will provide additional confirmation of the control level model before integration in a tokamak control system or integrated modeling suite. ML will be used to optimize the selection of training data consisting of RF current driven at different values of density profile, temperature profile, plasma current, and wavenumber. ML will also be used to facilitate classification of current drive from these input data. The output of this effort will be a validated classifier capable of determining the current drive profiles for HHFW CD and LHCD on a mille-second timescale. This will provide a breakthrough capability enabling real-time control of RF driven current profiles in experiments including ITER ICRF and use integrated modeling frameworks requiring thousands of current profile calculations in discharge simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrated current profile, normalized beta and NTM control in DIII-D

There is an increasing need for integrating individual plasma-control algorithms with the ultimate goal of simultaneously regulating more than one plasma property. Some of these integrated-control solutions should have the capability of arbitrating the authority of the individual plasma-control algorithms over the available actuators within the tokamak. Such decision-making process must run in real time since its outcome depends on the plasma state. Therefore, control architectures including supervisory and/or exception-handling algorithms will play an essential role in future fusion reactors like ITER. However, most plasma-control experiments in present devices have focused so far on demonstrating control solutions for isolated objectives. In this work, initial experimental results are reported for simultaneous current-profile control, normalized-beta control, and Neoclassical Tearing Mode (NTM) suppression in DIII-D. Neutral beam injection (NBI), electron-cyclotron (EC) heating & current drive (H&CD), and plasma current modulation are the actuation methods. The NBI power and plasma current are always modulated by the Profile Control category within the DIII-D Plasma Control System (PCS) in order to control both the current profile and the normalized beta. EC H&CD is utilized by either the Profile Control or the Gyrotron categories within the DIII-D PCS as dictated by the Off-Normal and Fault Response (ONFR) system, which monitors the occurrence of an NTM and regulates the authority over the gyrotrons. The total EC power and poloidal mirror angles are the gyrotron-related actuation variables. When no NTM suppression is required, the gyrotrons are used by the Profile Control category, but when NTM suppression is required, the ONFR transfers the authority over the gyrotrons to the NTM stabilization algorithm located in the Gyrotron category. Initial experimental results show that simultaneous control of different aspects of the plasma dynamics may improve the overall control and plasma performances. Also, the potential of the ONFR system to successfully integrate competing control algorithms is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗