Consequences of statistical sense determination for WIMP directional detection

We study the consequences of limited recoil sense reconstruction on the number of events required to reject isotropy and detect a WIMP signal using a directional detector. For a constant probability of determining the sense correctly, 3-d readout and zero background, we find that as the probability is decreased from 1.0 to 0.75 the number of events required increases by a factor of a few. As the probability is decreased further the number of events increases sharply, and isotropy can be rejected more easily by discarding the sense information and using axial statistics. This however requires an order of magnitude more events than vectorial data with perfect sense determination. We also consider energy dependent probabilities of correctly measuring the sense. Our main finding is that correctly determining the sense of the abundant, but less anisotropic, low energy recoils is most important.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The new ATLAS/LUCID detector

The new ATLAS luminosity monitor has many innovative aspects implemented. Its photomultipliers tubes are used as detector elements by using the Cherenkov light produced by charged particles above threshold crossing the quartz windows. The analog shaping of the readout chain has been improved, in order to cope with the 25 ns bunch spacing of the LHC machine. The main readout card is a quite general processing unit based on 12 bit - 500 MS/s Flash ADC and on FPGAs, delivering the processed data to 1.3 Gb/s optical links. The article will describe all these aspects and will outline future perspectives of the card for next generation high energy physics experiments. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A prototype scintillating-fibre tracker for the cosmic-ray muon tomography of legacy nuclear waste containers

A prototype scintillating-fibre detector system has been developed at the University of Glasgow in collaboration with the UK National Nuclear Laboratory (NNL) for the nondestructive assay of UK legacy nuclear waste containers. This system consists of two tracking modules above, and two below, the container under interrogation. Each module consists of two orthogonal planes of 2 mm-pitch fibres yielding one space point. Per plane, 128 fibres are read out by a single Hamamatsu H8500 64-channel MAPMT with two fibres multiplexed onto each pixel. A dedicated mapping scheme has been developed to avoid space point ambiguities and retain the high spatial resolution provided by the fibres. The configuration allows the reconstruction of the incoming and scattered muon trajectories, thus enabling the container content, with respect to atomic number Z, to be determined. Results are shown from experimental data collected for high-Z objects within an air matrix and, for the first time, within a shielded, concrete-filled container. These reconstructed images show clear discrimination between the low, medium and high-Z materials present, with dimensions and positions determined with sub-centimetre precision. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Star sensor/mapper with a self deployable, high-attenuation light shade for SAS-B

A star sensor/mapper to determine positional data for the small astronomy satellites was tested to detect stars of plus 4 visual magnitude. It utilizes two information channels with memory so that it can be used with a low-data-rate telemetry system. One channel yields star amplitude information; the other yields the time of star occurrence as the star passes across an N-slit reticle/photomultiplier detector system. Some of the features of the star sensor/mapper are its low weight of 6.5 pounds, low power consumption of 0.4 watt, bandwidth switching to match the satellite spin rate, optical equalization of sensitivity over the 5-by-10 deg field of view, and self-deployable sunshade. The attitude determination accuracy is 3 arc minutes. This is determined by such parameters as the reticle configuration, optical train, and telemetry readout. The optical and electronic design of the star sensor/mapper, its expansion capabilities, and its features are discussed.

Schenkel, F. W.↗

Global SO 2 Data Record from OMPS Instruments on the JPSS Constellation

NASA’s Earth Observing System (EOS) SO 2 climate data record (CDR) started in 2004, with the launch of the Aura/Ozone Monitoring Instrument (OMI) and is now being continued with the SNPP/Ozone Mapping and Profiler Suite (OMPS) launched in 2011. Both OMI and SNPP/OMPS SO 2 CDRs are produced with the Goddard principal component analysis (PCA) spectral fitting algorithm. An advantage of the data-driven PCA retrieval technique is that it enables highly consistent retrievals from different instruments, by inherently accounting for various instrumental factors. To further extend the EOS SO 2 CDR, we are implementing the PCA SO 2 retrieval algorithm with the L1B measurements from OMPS instruments flying on the Joint Polar Satellite System (JPSS) constellation. In this presentation, we will provide an update on our progress in NOAA-20 (launched in 2017) and NOAA-21 (launched in 2022) PCA SO2 retrievals. We will focus on our new NOAA-20/OMPS PCA SO 2 EOS continuity product, to be publicly released in fall of 2023. We will present statistical analyses on the quality of NOAA-20 PCA SO 2 product, including retrieval noise, biases over background areas, and long-term stability. We will compare our PCA SO 2 retrievals from NOAA-20 with those from OMI, SNPP/OMPS, and S5P/TROPOMI (TROPOspheric Monitoring Instrument) for anthropogenic sources as well as large volcanic plumes. We will also discuss the application of a new machine learning technique that helps to further reduce the noise of NOAA-20 SO 2 retrievals. In addition, we will present preliminary PCA SO 2 retrievals from NOAA-21/OMPS, including those from direct readout implementation for aviation disaster avoidance. Finally, we will share some first results applying the PCA algorithm to NASA’s geostationary TEMPO (Tropospheric Emissions: Monitoring of Pollution) instrument to obtain hourly, high resolution SO 2 data over North America.

SO2↗

Temperature-dependent calibration procedures for the silicon photomultiplier readout of the cosmic ray veto detector for the Mu2e experiment

The cosmic ray veto detector for the Mu2e experiment consists of scintillation bars embedded with wavelength-shifting fibers and read out by silicon photomultipliers (SiPMs). Here, in this manuscript, the calibration procedures of the SiPMs are described including corrections for the temperature dependence of their light yield. These corrections are needed as the SiPMs are not kept at a constant temperature due to the complexity and cost of implementing a cooling system on such a large detector. Rather, it was decided to monitor the temperature to allow the appropriate corrections to be made. The SiPM temperature dependence has been measured in a dedicated experiment and the calibration procedures were validated with data from production detectors awaiting installation at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards a 1000 tracks digital tape recorder

As the demand for high data rate (up to 1 Gb/s), high density (down to 1 sq micron/bit) tape recorder increases, the main investigation trend is an improvement of the well known helical scan concept. The drawbacks of this technology are also well known; sophisticated mechanics, head to tape contact, and wear problems. In our fixed head approach, the recorder mechanics is made much more simple, but the complexity is turned towards the integrated magnetic components, which have to record and reproduce hundreds of tracks in parallel. Our multiplexed write inductive head and magneto-optical readout head will be described, and the global system performances evaluated.

Coutellier, J. M.↗

Detector Control and Data Acquisition for the Wide-Field Infrared Survey Telescope (WFIRST) with a Custom ASIC

The Wide-Field Infrared Survey Telescope (WFIRST) will have the largest near-IR focal plane ever flown by NASA, a total of 18 4K x 4K devices. The project has adopted a system-level approach to detector control and data acquisition where 1) control and processing intelligence is pushed into components closer to the detector to maximize signal integrity, 2) functions are performed at the highest allowable temperatures, and 3) the electronics are designed to ensure that the intrinsic detector noise is the limiting factor for system performance. For WFIRST, the detector arrays operate at 90 to 100 K, the detector control and data acquisition functions are performed by a custom ASIC at 150 to 180 K, and the main data processing electronics are at the ambient temperature of the spacecraft, notionally approx.300 K. The new ASIC is the main interface between the cryogenic detectors and the warm instrument electronics. Its single-chip design provides basic clocking for most types of hybrid detectors with CMOS ROICs. It includes a flexible but simple-to-program sequencer, with the option of microprocessor control for more elaborate readout schemes that may be data-dependent. All analog biases, digital clocks, and analog-to-digital conversion functions are incorporated and are connected to the nearby detectors with a short cable that can provide thermal isolation. The interface to the warm electronics is simple and robust through multiple LVDS channels. It also includes features that support parallel operation of multiple ASICs to control detectors that may have more capability or requirements than can be supported by a single chip.

data acquisition↗

Lunar Glovebox Balance with Wireless Technology

The most important equipment required for processing lunar samples is a high-quality mass balance for maintaining accurate weight inventory, security, and scientific study. After careful review, a Curation Office memo by Michael Duke in 1978 chose the Mettler PL200 to be used for sample weight measurements inside the gloveboxes (Fig. 3). These commercial off-the-shelf (COTS) balances did not meet the strict accepted material requirements in the Lunar lab. As a result, each balance housing, weighing pan, and wiring was custom retrofitted to meet Lunar Operating Procedure (LOP) 54 requirements [for material construction restrictions]. The original design drawings for the custom housings, readout support stands, and wiring were done by the JSC engineering directorate. The 1977- 1978 schematics, drawings, and files are now housed in the curation Data Center. Per the design specifications, the housing was fabricated from aluminum grade 6061 T6, seamless welds, and anodized per MIL-A-8625 type I, class I. The balance feet were TFE Teflon and any required joints were sealed with Viton A gaskets. The readout display and support stands outside the glovebox were fabricated from 300 series stainless steel with #4 finish and mounted to the glovebox with welded bolts. Wire harnesses that linked the balance with the outside display and power were encapsulated with TFE Teflon and transported through custom Deutsch wire bulk head pass-through systems from inside to outside the glovebox. These Deutsch connectors were custom fabricated with 316L stainless steel bodies, Viton A O-rings, aluminum 6061 with electroless nickel plating, Teflon (replacing the silicone), and gold crimp connectors (no soldering). Many of the Deutsch connectors may have been used in the Apollo program high vacuum complex in building 37 and date to about 1968 to 1970.

Zeigler, Ryan A.↗

A Cylindrical GEM Detector with Analog Readout for the BESIII Experiment

Inner Trackers (IT) are key detectors in Particle Physics experiments; excellent spatial resolution, radiation transparency and hardness, and operability under high occupancies are main requirements. We aim to design, build and commission by 2017 a Cylindrical GEM (CGEM) detector candidate to be the new IT of the BESIII spectrometer, hosted on BEPC2 in IHEP, Beijing; BESIII data taking will last until at least 2020. The IT itself will represent an evolution w.r.t. the state of the art of GEM detectors, since the use of new kind of mechanical supports for the GEM foils will reduce the total radiation length of the detector and improve its tracking performance; an innovative design of the CGEM anode will allow for smaller capacitance and hence for bigger signals. The relatively strong BESIII magnetic field requires a new analogue readout; full custom front-end electronics, including a dedicated ASIC, will be designed and produced for optimal data collection. Prototype Beam Test results showing the measurement of the spatial resolution in a 1 Tesla magnetic field will be presented among with the mechanical design and simulations. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Causes and consequences of experimental variation in Nicotiana benthamiana transient expression

Infiltration of Agrobacterium tumefaciens into Nicotiana benthamiana has become a foundational technique in plant biology, enabling efficient delivery of transgenes in planta with technical ease, robust signal, and relatively high throughput. Despite transient expression’s prevalence in disciplines such as synthetic biology, little work has been done to describe and address the variability inherent in this system, a concern for experiments that rely on highly quantitative readouts. In a comprehensive analysis of N. benthamiana agroinfiltration experiments, we model sources of variability that affect transient expression. Our findings emphasize the need to validate normalization methods under the specific conditions of each study, as distinct normalization schemes do not always reduce variation either within or between experiments. Using a dataset of 1915 plants collected over three years, we develop a model of variation in N. benthamiana transient expression, using power analysis to determine the number of individual plants required for a given effect size. Drawing on our longitudinal data, these findings inform practical guidelines for minimizing variability through strategic experimental design and power analysis, providing a foundation for more robust and reproducible use of N. benthamiana in quantitative plant biology and synthetic biology applications.

Tang, Sophia N. [Joint BioEnergy Institute (JBEI),↗

Hadron production measurements for neutrino physics

One of the limiting factors for the precision of neutrino oscillation experiments is the uncertainty in the composition and spectrum of the neutrino flux. Recently, dedicated hadron production experiments have been taking data and are being planned to supply measurements which can significantly reduce these uncertainties. The HARP experiment has presented results on the measurements of the double-differential production cross-section of charged pions in proton interactions with beryllium, carbon, aluminium, copper, tin, tantalum and lead targets. These results are relevant for a detailed understanding of neutrino flux in accelerator neutrino experiments K2K (p-Al data) and MiniBooNE/SciBooNE (p-Be data), for a better prediction of atmospheric neutrino fluxes (p-C, {pi}{sup +}-C and {pi}{sup -}-C data) as well as for a systematic improvement of hadron production models. The E910 experiment at BNL has recently published their p-Be data. NA49 has measured pion production spectra in p-C interactions and a new experiment, NA61, is starting to take data using essentially the same detector. NA61 plans to measure production spectra for the T2K experiment and for the calculation of extended air showers. MIPP has taken data with a copy of the NuMI target and is progressing in the analysis of these data. An upgrade of the readout of this experiment can greatly increase its potential.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Binary Offset Effect in CCD Readout and Its Impact on Astronomical Data

We have discovered an anomalous behavior of CCD readout electronics that affects their use in many astronomical applications. An offset in the digitization of the CCD output voltage that depends on the binary encoding of one pixel is added to pixels that are read out one, two, and/or three pixels later. One result of this effect is the introduction of a differential offset in the background when comparing regions with and without flux from science targets. Conventional data reduction methods do not correct for this offset. We find this effect in 16 of 22 instruments investigated, covering a variety of telescopes and many different front-end electronics systems. The affected instruments include LRIS and DEIMOS on the Keck telescopes, WFC3 UVIS and STIS on HST, MegaCam on CFHT, SNIFS on the UH88 telescope, GMOS on the Gemini telescopes, HSC on Subaru, and FORS on VLT. The amplitude of the introduced offset is up to 4.5 ADU per pixel, and it is not directly proportional to the measured ADU level. We have developed a model that can be used to detect this "binary offset effect" in data, and correct for it. Understanding how data are affected and applying a correction for the effect is essential for precise astronomical measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

A Contrast Calibration Protocol for X-ray Speckle Visibility Spectroscopy

X-ray free electron lasers, with their ultrashort highly coherent pulses, opened up the opportunity of probing ultrafast nano- and atomic-scale dynamics in amorphous and disordered material systems via speckle visibility spectroscopy. However, the anticipated count rate in a typical experiment is usually low. Therefore, visibility needs to be extracted via photon statistics analysis, i.e., by estimating the probabilities of multiple photons per pixel events using pixelated detectors. Considering the realistic X-ray detector responses including charge cloud sharing between pixels, pixel readout noise, and gain non-uniformity, speckle visibility extraction relying on photon assignment algorithms are often computationally demanding and suffer from systematic errors. In this paper, we present a systematic study of the commonly-used algorithms by applying them to an experimental data set containing small-angle coherent scattering with visibility levels ranging from below 1% to ∼60%. We also propose a contrast calibration protocol and show that a computationally lightweight algorithm can be implemented for high-speed correlation evaluation.

47 OTHER INSTRUMENTATION↗

Analyzing Contents of a Computer Cache

The Cache Contents Estimator (CCE) is a computer program that provides information on the contents of level-1 cache of a PowerPC computer. The CCE is configurable to enable simulation of any processor in the PowerPC family. The need for CCE arises because the contents of level-1 caches are not available to either hardware or software readout mechanisms, yet information on the contents is crucial in the development of fault-tolerant or highly available computing systems and for realistic modeling and prediction of computing- system performance. The CCE comprises two independent subprograms: (1) the Dynamic Application Address eXtractor (DAAX), which extracts the stream of address references from an application program undergoing execution and (2) the Cache Simulator (CacheSim), which models the level-1 cache of the processor to be analyzed, by mimicking what the cache controller would do, in response to the address stream from DAAX. CacheSim generates a running estimate of the contents of the data and the instruction subcaches of the level-1 cache, hit/miss ratios, the percentage of cache that contains valid or active data, and time-stamped histograms of the cache content.

Beahan, John↗

Development of a strip-shaped X-ray mapping system for 9-cell superconducting cavities

Electrons emitted via field emission during superconducting (SC) radio-frequency (RF) cavity tests at vertical test stands often collide with the iris region inside the cavity, generating X-rays at these locations. In 1.3 GHz 9-cell SC RF cavities designed for the International Linear Collider (ILC), stiffener rings located outside the iris region between cells can interfere with X-ray detection, complicating the precise identification of field emission sites. Hence, in this study, we developed a high-density strip X-ray mapping systems (sX-map) that can be inserted into the iris region of ILC-type 9-cell SC RF cavities. This sX-map facilitates efficient and accurate detection of X-rays generated near the irises, unaffected by the presence of stiffener rings. The sX-map consisted of 32 sensors per strip, with sensors spaced approximately 10 mm apart. It was deployed in every iris of the 9-cell cavity, using a total of 320 sensors. A multiplexer was employed to facilitate the readout of a large number of detectors using a minimal number of signal lines, connecting the strips inside within the vertical test cryostat. In a vertical test conducted at Jefferson Lab (JLab), we demonstrated the capability of sX-map to detect X-rays despite the presence of a stiffener ring. This paper presents the detailed design of the sX-map and the results from the vertical test at JLab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterising Encapsulated Nuclear Waste using Cosmic-ray Muon Tomography (MT)

A prototype scintillating-fibre detector system has been developed at the University of Glasgow in collaboration with the UK National Nuclear Laboratory (NNL) for the nondestructive assay of UK legacy nuclear waste containers. This system consists of four tracking modules, two above and two below the container under interrogation. Each module consists of two orthogonal planes of 2 mm-pitch fibres yielding one space point. Per plane, 128 fibres are read out by a single Hamamatsu H8500 64-channel MAPMT with two fibres multiplexed onto each pixel. The configuration allows the reconstruction of the incoming and scattered muon trajectories, thus enabling the container content, with respect to atomic number Z, to be determined. Results are shown from experimental data collected for high-Z objects within an air matrix and within a shielded, concrete-filled container. These reconstructed images show clear discrimination between the low, medium and high-Z materials present, with dimensions and positions determined with sub-centimetre precision. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The ladder and readout cables of intermediate silicon strip detector for sPHENIX

A new silicon-strip-type detector was developed for precise charged-particle tracking in the central rapidity region of heavy ion collisions. A new detector and collaboration at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory is sPHENIX, which is a major upgrade of the PHENIX detector. The intermediate tracker (INTT) is part of the advanced tracking system of the sPHENIX detector complex together with a CMOS monolithic-active-pixel-sensor based silicon-pixel vertex detector, a time-projection chamber, and a micromegas-based detector. The INTT detector is barrel shaped and comprises 56 silicon ladders. Two different types of strip sensors of 78 micron pitch and 320 micron thick are mounted on each half of a silicon ladder. Each strip sensor is segmented into 8 × 2 and 5 × 2 blocks with lengths of 16 and 20 mm. Strips are read out with a silicon strip-readout (FPHX) chip. In order to transmit massive data from the FPHX to the down stream readout electronics card (ROC), a series of long and high speed readout cables were developed. This document focuses on the silicon ladder, the readout cables, and the ROC of the INTT. The radiation hardness is studied for some parts of the INTT devices in the last part of this document, since the INTT employed some materials from the technology frontier of the industry whose radiation hardness is not necessarily well known.

43 PARTICLE ACCELERATORS↗