Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Considerations on the use of an Anti-Compton Suppression Technique for the Measurement of Low Energy Gamma Rays in Dense Waste Materials - 18144

The Anti-Compton Spectrometry (ACS) technique is a gamma-ray measurement method which, in the presence of gamma rays sources emitting at higher energies, may improve the signal-to-continuum ratio of lower energy photo-peaks. It is used to improve assay precision and statistical detection limits. The typical approach surrounds the collimated High Purity Germanium (HPGe) detector by a NaI(Tl) guard which vetoes detected gamma-rays scattered out of the Ge-spectrometer and therefore by definition events do not contribute to a full energy peak in the HPGe detector. The present publication focuses on the applicability, advantages and drawbacks of ACS when considered for the purpose of enhancing measurement performances of non-destructive waste assay systems. In particular, the applicability and benefit of implementing ACS for the quantification of {sup 241}Am in high density waste will be presented. Such an application is directly relevant to measurement scenarios where the accuracy of the {sup 241}Am quantification is central to the radioactive waste meeting some acceptance criteria for near surface disposal, such as total alpha decay activity limits in 300 years. This work is also relevant to any measurement applications for which the Compton background generated by higher energy nuclides present in the waste and interacting with the detector significantly degrade the performance of standard high resolution gamma spectroscopy for low energy nuclides. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Detection of Carbendazim Residues in Aqueous Samples by Fluorescent Quenching of Plant Esterase

A method based on the inhibition of plant esterase from pesticides has been proposed and validated for the determination of carbendazim residues in aqueous samples. After optimization in pH, temperature, and detection time, a lower detection limit of 0.105 μM was obtained in the linear range from 0.105 to 41.84 μM. Upon analysis of the detection mechanism, carbendazim was found to be binding to plant esterase via the van der Waals force and the hydrogen bond with a single binding site through an exothermic reaction. Moreover, the proposed method was satisfactorily applied to the analysis of carbendazim residues in different aqueous samples, obtaining a remarkably good agreement with the standardized reference method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ToF-SIMS in material research: A view from nanoscale hydrogen detection

Hydrogen in materials has attracted tremendous interest as its incorporation leads to significant alterations in nanoscale structure, composition, and chemistry, impacting functional properties. It has also been integral to nuclear fusion reactors and is considered a future clean energy source. However, nanoscale characterization and manipulation of hydrogen in materials are challenging as only a selected few analytical techniques can readily detect hydrogen, among which time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a unique and powerful one due to its excellent detection limit along with decent depth and lateral resolutions. Here, in this review, we discuss, using selected examples, how to detect and quantify hydrogen in materials by ToF-SIMS and its impact on revealing the hydrogenation/protonation-induced novel functional states in different classes of materials. In addition, we present our protocols on sample preparation and experimental conditions optimization, allowing us to achieve the best possible results. Finally, we highlight future research directions that can lead to the discovery of novel functional states and ultimately provide a deeper understanding of scientific questions in materials science.

36 MATERIALS SCIENCE↗

SEARCH FOR THE OPTICAL COUNTERPART TO SGR 0418+5729

We report broadband Hubble Space Telescope imaging of the field of soft {gamma}-ray repeater SGR 0418+5729 with Advanced Camera for Surveys/Wide Field Channel and Wide Field Camera 3/IR. Observing in two wide filters, F606W and F110W, we find no counterpart within the positional error circle derived from Chandra observations, to limiting magnitudes m{sub F606W} > 28.6 and m{sub F110W} > 27.4 (Vega system), equivalent to reddening-corrected luminosity limits L{sub F606W} < 5 Multiplication-Sign 10{sup 28} and L{sub F110W} < 6 Multiplication-Sign 10{sup 28} erg s{sup -1} for a distance d = 2 kpc, at 3{sigma} confidence. This, in turn, imposes lower limits on the contemporaneous X-ray/optical flux ratio of {approx_equal}1100 and the X-ray/near-infrared flux ratio of {approx_equal}1000. We derive an upper limit on the temperature and/or size of any fall-back disk around the magnetar. We also compare the detection limits with observations of other magnetars.

79 ASTRONOMY AND ASTROPHYSICS↗

A sensitive method for measuring atmospheric concentrations of sulfur dioxide

A new method for measuring tropospheric sulfur dioxide concentrations is proposed which is based on the mist chamber sampling method. At the present stage of development, the detection limit of the method is approximately 20 parts per trillion for a 45-min sampling time, with lower concentrations detectable with lower precision. The overall reproducibility of the method (+/-95 percent confidence intervals) is estimated at +/-10 percent. The technique is relatively simple, inexpensive, and lightweight, making it ideally suited for numerous field applications in atmospheric chemistry and biogeochemical studies from both ground-based and airborne platforms.

Klemm, O.↗

C-O volatiles in Apollo 15 and Apollo 17 picritic glasses

A15 and A17 primitive picritic glasses have been examined by FTIR for the presence of dissolved C-O species to determine the role of C-O gasses on driving lunar fire-fountains. A15 green and yellow glasses were extensively studied and found to be free of dissolved C species down to FTIR detection limits (10-100 ppm; species and sample specific). Preliminary data on A17 orange glasses are similarly devoid of FTIR detectable C-O species. Re-analyses of the C-O driving mechanism theory for mare volcanism demonstrates the need to determine the fO2 of the lunar interior; the factor that most critically determined the role of C gasses in the fire-fountaining events. Oxygen fugacities equivalent to IW-0.5 and above imply dissolved CO3(=) in the primitive glasses at levels above FTIR detection. The f02's below IW-0.5 imply concentrations of CO3(=) below FTIR detection. Recent data suggesting lunar mantle fO2's of IW-2 or less, strongly mitigate against finding FTIR measurable dissolved CO3(=) consistent with the findings of this study.

Rutherford, Malcolm J.↗

MOD: An Organic Detector for the Future Exploration of Mars

The Mars Organic Detector (MOD) is designed to assess whether organic compounds, possibly associated with life, are present in Martian rock and soil samples. MOD has a detection limit that is at least two orders of magnitude more sensitive than the Viking GCMS. MOD is focused on detecting amino acids, amines and PAH (polycyclic aromatic hydrocarbons). Amino acids play an essential role in biochemistry on Earth and PAH are widespread throughout the universe and can provide an indication of the delivery of meteoritic organic material to Mars. The advantage of MOD is the absence of wet chemistry and its simple and robust design. The sample will be extracted from the mineral matrix (0.1 - 1 g of rock-powder) using sublimation and analyzed with a fluorescence detector. The isolation method is based on the fact that amino acids and PAH are volatile at temperatures greater than 150C. The fluorescence detection scheme is based on UV excitation with LED's, optical filters, PrN diode photon detector and a sample calibration reservoir. Fluorescamine is used as a fluorescing reagent for amino acids and amines, while PAH are naturally fluorescent. There is no sample preparation required and the turnaround time for a single analysis is on the order of minutes.

Kminek, G.↗

Data Summary Report for Soil and Slab Sampling at Former Building 175

Lawrence Livermore National Security (LLNS) and the U.S. Department of Energy (DOE) are in the process of returning the area where Building 175 existed to beneficial use for future site development. The completed assessment will help LLNS and DOE to outline project scope and costs associated with the removal, characterization, and disposal of materials generated when the concrete slab for the former building and any associated remaining subsurface structures are demolished. Slab removal under the Transition & Disposition process requires full screening for potential site contamination to determine appropriate future land use. Borehole locations and depths were designed to correctly assess DOE’s future liability for characterizing residual vadose zone contamination. If a residual source area is identified at depth, DOE will need to evaluate the additional cost of future subsurface cleanup (with limited access) due to planned development. This is necessary to leave the location in a “ready-to-build” status. As a result, Phase II sampling requirements may in some cases extend beyond the construction zone required for slab removal to ensure the necessary due diligence. To avoid the potential spread of contamination and/or the creation of an environmental release by impacting the integrity of known contamination areas (e.g., pit within room 102 and the east to west boundary seam), these locations were not sampled for this project. During demolition of the slab, these locations and their underlying soils should be further evaluated. The assessment was conducted in accord with the May 2022 Lawrence Livermore National Laboratory Former Building 175 Assessment Soil Sampling and Analysis Plan / Quality Assurance Plan. Thirty-six, direct-push borings were advanced, along with collecting concrete (where present) and soil samples for laboratory analyses. Thirty-two of the borings were advanced to a depth of 25 feet below ground (bgs), and four borings were advanced to a depth of 55 feet bgs. The concrete slab for former Building 175 ranged from approximately 8 inches to over two feet in thickness. Soils encountered during the investigation consisted primarily of clayey silt, with interbeds of sandy gravel and silty sand to the total depth explored of 55 feet bgs. Field photoionization detector readings – checking for volatile organic compound (VOC) vapors in soils, ranged from zero (0) to a peak of 33 parts per million at 25 feet bgs in boring PC-B175- 028. The cause for the peak reading is unknown, however, no visually discolored or odorous soils were encountered during the assessment and all VOC results were below Lawrence Livermore National Laboratory’s (LLNL’s) Soil Screening and Management Plan (SSMP) soil screening levels (SSL). Groundwater was not encountered during the assessment and is expected to occur at roughly 65 feet bgs in the project area. No metals were detected at concentrations of concern in the concrete core samples collected and analyzed. Low gross alpha and beta activity concentrations were detected in the concrete core samples collected and analyzed. The detected activity concentrations would appear to be from naturally occurring radioactive isotopes, i.e., potassium 40, present in the raw materials used to make concrete and not artificially added. Tritium was not detected above the testing laboratory's Method Detection Limit (MDL) in any of the concrete core samples collected and analyzed. The radioactive isotopes - actinium 228, bismuth 214, lead 212, lead 214, potassium 40, radium 226, radium 228, and thallium 208, were detected at low activity concentrations in the concrete core samples analyzed. Based on the detected activity concentrations, the isotopes would appear to be naturally occurring in the raw materials used to make concrete and not artificially added. Acetone – a common laboratory contaminant, was detected in nine of the soil samples collected and analyzed. Concentrations of two other volatile organic compounds (benzene and tetrachloroethene) were detected in five of the soil samples analyzed. All concentrations were below SSLs. Total petroleum hydrocarbons as diesel range organics were detected at 43.9 milligrams per kilogram (mg/kg) in the 20-foot bgs duplicate sample from boring PC-B175-007. Total petroleum hydrocarbons as motor oil were detected at 7.20 mg/kg in the 15-foot bgs routine sample from boring PC-B175-001, and at 20.7 mg/kg in the 20-foot bgs duplicate sample from boring PC-B175-007. The SSL for diesel-range TPHs is 260 mg/kg. LLNL does not have an SSL for motor oil range TPHs. No indications of a release, e.g., visibly stained, or odorous soil, were present at the boring locations. No samples collected contained polychlorinated biphenyls (PCBs) in concentrations above the laboratory reporting limit. Arsenic was detected above its SSL of 8.51 mg/kg in the 25-foot bgs routine sample collected from boring PC-B175-023. Nickel was detected above its SSL of 86.0 mg/kg in the 10-foot bgs routine sample from boing PC-B175-005, the 20-foot bgs routine sample from boring PC-B175-025, and the 25-foot bgs routine sample from boring PC-B175-034. The detected concentrations, however, were well below ten times (10x) their respective STLCs. Gross alpha and/or gross beta were detected above their respective SSL activity concentrations in three routine soil samples. Retesting (two per sample) of the samples showed that the initial reported activity concentrations were anomalous. Tritium was not detected in any of the routine or duplicate soil samples collected and analyzed during the investigation. The radioactive isotopes - actinium 228, bismuth 212 and 214, lead 212 and 214, potassium 40, radium 224, 226 and 228, thallium 208, thorium 234 and uranium, were detected at low activity concentrations in the soil samples analyzed for radioactive constituents. The detected isotopes and their associated activity concentrations are typical of those naturally occurring in the marine-type sedimentary deposits underlying the Livermore Valley. No radiological controls are necessary for the soil evaluated.

54 ENVIRONMENTAL SCIENCES↗

Atomically Precise Hexanuclear Ce(IV) Clusters as Functional Fluorescent Nanosensors for Rapid One-Step Detection of PFAS

Here, the presence of poly- and perfluoroalkyl substances (PFAS) in the environment is associated with adverse health effects but measuring PFAS is challenging due to the associated high cost and technical complexities of the analysis. Here, the reactivity of atomically precise metal-oxo clusters is reported and the foundation for their use is provided as fluorescent nanosensors for PFAS detection. The material comprises crystalline, water soluble, hexanuclear cerium-oxo clusters [Ce 6 (µ 3 -O) 4 (µ 3 -OH) 4 ] 12+ decorated with glycine molecules (Ce-Gly) characterized by fluorescence emission at 353 nm. The Ce-Gly fluorescence is found sensitive to long chain carboxylated PFAS of CF 3 –(CF 2 ) n –, where n ≥ 6, such as perfluorooctanoic, perfluorononanoic and perfluorodecanoic acids. This unique reactivity leads to a change in the emission spectra in a concentration dependent manner, enabling PFAS detection through ligand exchange and aggregation-induced emission (AIE) enhancement. No significant cross-reactivity from potentially co-existing species, including sulfonated PFAS, octanoic and dodecanoic acids, humic acid, and inorganic ions is observed. With an optimal concentration of 3.3 µg mL -1 Ce-Gly, the method demonstrated detection limits of 0.24 ppb for PFOA and 0.4 ppb for PFNA. These findings highlight the potential of fluorescence-based detection strategies utilizing nanoscale probes such as Ce-Gly as fluorescent probes and nanosensors for PFAS.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Long-term Investigations of {sup 134}Cs and {sup 137}Cs Activity Concentrations in Honey from Croatia

This paper presents the results of long-term post-Chernobyl investigations of {sup 134}Cs and {sup 137}Cs activity concentrations in multifloral and chestnut honey sampled in northwest Croatia. For both radionuclides, the activity concentrations peaked in May 1986, decreasing exponentially until the mid-1990 s, when they fell under the detection limit for both radionuclides. After the Fukushima-Daiichi accident in 2011, the presence of both radionuclides in honey was detected once again. The ecological half-life was estimated to be 1.67 and 1.45 years for {sup 137}Cs and {sup 134}Cs, respectively. The correlation between {sup 134}Cs and {sup 137}Cs activity concentrations in fallout and honey was very good, indicating fallout to be the main source of honey contamination. The observed {sup 134}Cs/{sup 137}Cs activity ratio in honey was similar to the ratio found in other environmental samples. The estimated collective effective doses for the Croatian population incurred by honey consumption indicate that honey was not a critical pathway for the transfer of {sup 134}Cs and {sup 137}Cs from fallout to humans.

54 ENVIRONMENTAL SCIENCES↗

Striking luminescence phenomena of carbon dots and their applications as a double ratiometric fluorescence probes for H2S detection

Here, we report some new observations on the luminescence of carbon dots (CDs) that are passivated with polyethylene glycol, and explored them, for the first time, as highly sensitive H2S detection probe. The as-prepared CDs have an ultraviolet (UV) emission at 350 nm and a green emission at 540 nm when excited at 270 nm, but they have only a green emission at 523 nm when excited at 365 nm. As Na2S is added to the CDs, the UV emission decreases gradually, while the green emission increases slightly, and interestingly a new emission appears at 455 nm is increased linearly in intensity with the increase of Na2S concentration. The blue emission at 455 nm is from the intrinsic core of CDs, and the green emissions at 540 or 523 nm are from their surface states, while the UV emission at 350 nm is from the anchored PEG. Both the emission intensity ratios of F-450/F-350 and F-455/F-523 show an excellent linear relationship with the Na2S concentration in the range of 0-800 mu M, and the detection limit estimated from both of them is approximately 7.0 nM, indicating our method is the most sensitive H2S CDs based detection method reported thus far. Furthermore, the detection was tested successfully for H2S imaging in live cells. We propose that the interactions of H2S with the CDs and the anchored ligands, as well as the energy transfer between the ligands and the CDs, are responsible for the luminescence responses for H2S detection. Our studies enrich the world of carbon dots with plenty of potential applications. (C) 2020 Elsevier Ltd. All rights reserved.

Bioimaging↗

Ambient ion focusing from a field-free region to a detector: enhanced signal for explosives and drug detection with mass spectrometry

This study demonstrates ion focusing at ambient pressure and increased ion signal by creating a voltage gradient from a field-free region to a detector, thereby improving the detection of chemicals, such as explosives and drugs. At ambient pressure, ion loss and resulting signal reduction pose challenges that limit detection sensitivity in analytical instruments. Techniques to increase sensitivity, such as atmospheric flow tube-mass spectrometry (AFT-MS), extend ion-molecule reaction times but result in significant overall ion loss due to diffusion. Ion manipulation techniques, though challenging at ambient pressure, can mitigate these losses by concentrating ions toward the detector inlet. Using SIMION, ion trajectories were modeled with a voltage gradient applied between a flow tube and a detector, revealing ion focusing at ambient pressure. Experimental verification with an atmospheric flow tube employed both mass spectrometry and Faraday plate detectors to measure ion beam profiles across varying flow rates, tube diameters, and voltage gradients. Application of a voltage gradient effectively directed ions to the axial center of the flow tube, narrowed ion beam width, and increased signal intensity by 5 to 10 times compared to conditions without a voltage gradient. This ion focusing approach shows promise for improving sensitivity in ambient-pressure instruments. This technique has the potential to enhance detection levels in security and forensic applications, with particular benefits for field-portable devices used at checkpoints to identify explosives and drugs.

ambient pressure↗

A Raman cell based on hollow core photonic crystal fiber for human breath analysis

Purpose: Breath analysis has a potential prospect to benefit the medical field based on its perceived advantages to become a point-of-care, easy to use, and cost-effective technology. Early studies done by mass spectrometry show that volatile organic compounds from human breath can represent certain disease states of our bodies, such as lung cancer, and revealed the potential of breath analysis. But mass spectrometry is costly and has slow-turnaround time. The authors’ goal is to develop a more portable and cost effective device based on Raman spectroscopy and hollow core-photonic crystal fiber (HC-PCF) for breath analysis. Methods: Raman scattering is a photon-molecular interaction based on the kinetic modes of an analyte which offers unique fingerprint type signals that allow molecular identification. HC-PCF is a novel light guide which allows light to be confined in a hollow core and it can be filled with a gaseous sample. Raman signals generated by the gaseous sample (i.e., human breath) can be guided and collected effectively for spectral analysis. Results: A Raman-cell based on HC-PCF in the near infrared wavelength range was developed and tested in a single pass forward-scattering mode for different gaseous samples. Raman spectra were obtained successfully from reference gases (hydrogen, oxygen, carbon dioxide gases), ambient air, and a human breath sample. The calculated minimum detectable concentration of this system was ∼15 parts per million by volume, determined by measuring the carbon dioxide concentration in ambient air via the characteristic Raman peaks at 1286 and 1388 cm{sup −1}. Conclusions: The results of this study were compared to a previous study using HC-PCF to trap industrial gases and backward-scatter 514.5 nm light from them. The authors found that the method presented in this paper has an advantage to enhance the signal-to-noise ratio (SNR). This SNR advantage, coupled with the better transmission of HC-PCF in the near-IR than in the visible wavelengths led to an estimated seven times improvement in the detection sensitivity. The authors’ prototype device also demonstrated a 100-fold improvement over a recently reported detection limit of a reflective capillary fiber-based Raman cell for breath analysis. Continued development is underway to increase the detection sensitivity further to reach practical clinical applications.

60 APPLIED LIFE SCIENCES↗

Spectroelectrochemical Sensor: Development and Applications

This paper is being submitted to the 215th ECS (Electrochemical Society) Meeting, San Francisco, California | May 24-29, 2009 The spectroelectrochemical sensor concept uses electrochemistry to modulate an optical signal to give improved selectivity. The sensor consists of an optically transparent electrode/waveguide coated with a thin film that preconcentrates the analyte. The sensor concept was first demonstrated with ferricyanide and later it was shown to work on a complex sample by detecting ferrocycanide in radioactive Hanford tank waste. Nafion, partially sulfonated polystyrene-block-polyethylene-ran-butylene)block-polystyrene (SSEBS), and quaternized poly(vinylpyridine) (QPVP) are examples of polymers used for the thin film. Detection limits achieved by the sensor are 10-5 to 10-8 M using change in absorbance as the mode of detection and about 10-10 M using fluorescence. A sensor has been developed for detection of [Re(dmpe)3]+ where dmpe = dimethylphosphinoethane, which serves as a nonradioactive analogue for complexes of radioactive 99Tc. Some polycyclic aromatic hydrocarbons have appropriate electrochemical and spectroscopic properties for spectroelectrochemical detection as demonstrated for 1-hydroxypyrene and its conjugate 1-hydroxypyrene-glucuronide.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Emission Spectra of Uranium Particulates at High Temperature

The emission spectrum of micron-scale uranium particulates at high temperatures in the ultraviolet, visible, and near-infrared spectral regions is investigated using a heterogeneous shock tube. Temperatures from 3000 to 9000 K are characterized in an inert argon environment and with incremental amounts of added oxygen. Atomic line spectra do not emerge above the continuum emission spectrum until between 4500 and 5000 K in pure argon, and 6100 and 6600 K in 1% oxygen. For 5% oxygen, however, the threshold for atomic emission drops below 3800 K. Uranium monoxide molecular emission in the strongest visible band at 595.4 nm is not observed at any condition. Uncertainties in particle temperature determination in high-temperature shock tube environments are discussed, and limitations to such measurements are presented, such as those from experimental factors such as the powder loading method and expected detection limits of uranium species in relevant conditions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A New Field Instrument for Leaf Volatiles Reveals an Unexpected Vertical Profile of Isoprenoid Emission Capacities in a Tropical Forest

Both plant physiology and atmospheric chemistry are substantially altered by the emission of volatile isoprenoids (VI), such as isoprene and monoterpenes, from plant leaves. Yet, since gaining scientific attention in the 1950’s, empirical research on leaf VI has been largely confined to laboratory experiments and atmospheric observations. Here, we introduce a new field instrument designed to bridge the scales from leaf to atmosphere, by enabling precision VI detection in real time from plants in their natural ecological setting. With a field campaign in the Brazilian Amazon, we reveal an unexpected distribution of leaf emission capacities (EC) across the vertical axis of the forest canopy, with EC peaking in the mid-canopy instead of the sun-exposed canopy surface, and moderately high emissions occurring in understory specialist species. Compared to the simple interpretation that VI protect leaves from heat stress at the hot canopy surface, our results encourage a more nuanced view of the adaptive role of VI in plants. We infer that forest emissions to the atmosphere depend on the dynamic microenvironments imposed by canopy structure, and not simply on canopy surface conditions. We provide a new emissions inventory from 52 tropical tree species, revealing moderate consistency in EC within taxonomic groups. We highlight priorities in leaf volatiles research that require field-portable detection systems. Our self-contained, portable instrument provides real-time detection and live measurement feedback with precision and detection limits better than 0.5 nmol VI m -2 leaf s -1 . We call the instrument ‘PORCO’ based on the gas detection method: photoionization of organic compounds. We provide a thorough validation of PORCO and demonstrate its capacity to detect ecologically driven variation in leaf emission rates and thus accelerate a nascent field of science: the ecology and ecophysiology of plant volatiles.

54 ENVIRONMENTAL SCIENCES↗

Real-Time Ozone Detection Based on a Microfabricated Quartz Crystal Tuning Fork Sensor

A chemical sensor for ozone based on an array of microfabricated tuning forks is described. The tuning forks are highly sensitive and stable, with low power consumption and cost. The selective detection is based on the specific reaction of the polymer with ozone. With a mass detection limit of ~2 pg/mm 2 and response time of 1 second, the sensor coated with a polymer sensing material can detect ppb-level ozone in air. The sensor is integrated into a miniaturized wearable device containing a detection circuit, filtration, battery and wireless communication chip, which is ideal for personal and microenvironmental chemical exposure monitoring.

sensitive↗