Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Calculation of k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} for several small detectors and for two linear accelerators using Monte Carlo simulations

Purpose: The scope of this study was to determine a complete set of correction factors for several detectors in static small photon fields for two linear accelerators (linacs) and for several detectors. Methods: Measurements for Monte Carlo (MC) commissioning were performed for two linacs, Siemens Primus and Elekta Synergy. After having determined the source parameters that best fit the measurements of field specific output factors, profiles, and tissue-phantom ratio, the generalized version of the classical beam quality correction factor for static small fields, k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}, were determined for several types of detectors by using the egs{sub c}hamber Monte Carlo user code which can accurately reproduce the geometry and the material composition of the detector. The influence of many parameters (energy and radial FWHM of the electron beam source, field dimensions, type of accelerator) on the value of k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} was evaluated. Moreover, a MC analysis of the parameters that influence the change of k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} as a function of field dimension was performed. A detailed analysis of uncertainties related to the measurements of the field specific output factor and to the Monte Carlo calculation of k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} was done. Results: The simulations demonstrated that the correction factor k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} can be considered independent from the quality beam factor Q in the range 0.68 {+-} 0.01 for all the detectors analyzed. The k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} of PTW 60012 and EDGE diodes can be assumed dependent only on the field size, for fields down to 0.5 x 0.5 cm{sup 2}. The microLion, and the microchambers, instead, must be used with some caution because they exhibit a slight dependence on the radial FWHM of the electron source, and therefore, a correction factor only dependent on field size can be used for fields {>=}0.75 x 0.75 and {>=}1.0 x 1.0 cm{sup 2}, respectively. The analysis of uncertainties gave an estimate of uncertainty for the 0.5 x 0.5 cm{sup 2} field of about 0.7% (1{sigma}) for k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} factor and of about 1.0% (1{sigma}) for the field output factor, {Omega}{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}, of diodes, microchambers, and microLion. Conclusions: Stereotactic diodes with the appropriate k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} are recommended for determining {Omega}{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} of small photon beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Poster - 16: Time-resolved diode dosimetry for in vivo proton therapy range verification: calibration through numerical modeling

Purpose: A method to refine the implementation of an in vivo, adaptive proton therapy range verification methodology was investigated. Simulation experiments and in-phantom measurements were compared to validate the calibration procedure of a time-resolved diode dosimetry technique. Methods: A silicon diode array system has been developed and experimentally tested in phantom for passively scattered proton beam range verification by correlating properties of the detector signal to the water equivalent path length (WEPL). The implementation of this system requires a set of calibration measurements to establish a beam-specific diode response to WEPL fit for the selected ‘scout’ beam in a solid water phantom. This process is both tedious, as it necessitates a separate set of measurements for every ‘scout’ beam that may be appropriate to the clinical case, as well as inconvenient due to limited access to the clinical beamline. The diode response to WEPL relationship for a given ‘scout’ beam may be determined within a simulation environment, facilitating the applicability of this dosimetry technique. Measurements for three ‘scout’ beams were compared against simulated detector response with Monte Carlo methods using the Tool for Particle Simulation (TOPAS). Results: Detector response in water equivalent plastic was successfully validated against simulation for spread out Bragg peaks of range 10 cm, 15 cm, and 21 cm (168 MeV, 177 MeV, and 210 MeV) with adjusted R{sup 2} of 0.998. Conclusion: Feasibility has been shown for performing calibration of detector response for a given ‘scout’ beam through simulation for the time resolved diode dosimetry technique.

60 APPLIED LIFE SCIENCES↗

Detector Tilt Considerations in Bragg Coherent Diffraction Imaging: A Simulation Study

This paper addresses the three-dimensional signal distortion and image reconstruction issues in X-ray Bragg coherent diffraction imaging (BCDI) in the event of a general non-orthogonal orientation of the area detector with respect to the diffracted beam. Growing interest in novel BCDI adaptations at fourth-generation synchrotron light sources has necessitated improvisations in the experimental configuration and the subsequent data analysis. One such possibly unavoidable improvisation that is envisioned in this paper is a photon-counting area detector whose face is tilted away from the perpendicular to the Bragg-diffracted beam during the acquisition of the coherent diffraction signal. We describe a likely circumstance in which one would require such a detector configuration, along with the experimental precedent at third-generation synchrotrons. Using physically accurate diffraction simulations from synthetic scatterers in the presence of such tilted detectors, we analyze the general nature of the observed signal distortion qualitatively and quantitatively and provide a prescription to correct for it during image reconstruction. Our simulations and reconstructions are based on an adaptation of the known theory of BCDI sampling geometry, as well as the recently developed projection-based methods of wavefield propagation. Such configurational modifications and their numerical remedies are potentially valuable in realizing unconventional coherent diffraction measurement geometries, eventually paving the way for the integration of BCDI into new material characterization experiments at next-generation light sources.

36 MATERIALS SCIENCE↗

Extension of the Focusable Mass Range in Distance-of-Flight Mass Spectrometry with Multiple Detectors

Since the underlying theory of Distance-of-Flight Mass Spectrometry (DOFMS) was reported in 2007,[1] laboratory results[2, 3] have proven its practical viability. However, these previous implementations of DOFMS considered ion detection only over narrow DOF-detection windows, with 25-mm being the greatest detection length explored. These small mass windows cannot be used to evaluate how DOFMS focusing performs over greater DOF detection lengths and mass ranges. In the present study, we expand on previous studies by placing two spatially selective ion detectors along the detection plane of the DOFMS instrument. Ion signals are simultaneously collected from both DOF detectors in order to simulate DOFMS performance with a longer spatially selective ion detector.

Gundlach-Graham, Alexander W↗

Denoising diffusion models with geometry adaptation for high fidelity calorimeter simulation

Simulation is crucial for all aspects of collider data analysis, but the available computing budget in the High Luminosity LHC era will be severely constrained. Generative machine learning models may act as surrogates to replace physics-based full simulation of particle detectors, and diffusion models have recently emerged as the state of the art for other generative tasks. Here, we introduce CaloDiffusion, a denoising diffusion model trained on the public CaloChallenge datasets to generate calorimeter showers. Our algorithm employs 3D cylindrical convolutions, which take advantage of symmetries of the underlying data representation. To handle irregular detector geometries, we augment the diffusion model with a new geometry latent mapping (GLaM) layer to learn forward and reverse transformations to a regular geometry that is suitable for cylindrical convolutions. The showers generated by our approach are nearly indistinguishable from the full simulation, as measured by several different metrics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo simulation of the data acquisition chain of scintillation detectors

The good performance of a detector can be strongly affected by the instrumentation used to acquire the data. The possibility of anticipating how the acquisition chain will affect the signal can help in finding the best solution among different set-ups. In this work we developed a Monte Carlo code that aims to simulate the effect of the various components of a digital Data Acquisition system (DAQ) applied to scintillation detectors. The components included in the model are: the scintillator, the photomultiplier tube (PMT), the signal cable and the digitizer. We benchmarked the code against real data acquired with a NE213 scintillator, comparing simulated and real signal pulses induced by gamma-ray interaction. Then we studied the dependence of the energy resolution of a pulse height spectrum (PHS) on the sampling frequency and the bit resolution of the digitizer. We found that exceeding some values of the sampling frequency and the bit resolution improves only marginally the performance of the system. The method can be applied for the study of various detector systems relevant for nuclear techniques, such as in fusion diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MCNP6 simulated performance of Micro-Pocket Fission Detectors (MPFDs) in the Transient REActor Test (TREAT) Facility

Micro-Pocket Fission Detectors (MPFDs) are under development for in-core neutron flux measurements at the Transient REActor Test facility (TREAT) and in other experiments at Idaho National Laboratory (INL). The sensitivity of MPFDs to the energy dependent neutron flux at TREAT has been determined for 0.0300-μm thick active material coatings of 242 Pu, 232 Th, natural uranium, and 93% enriched 235 U. Self-shielding effects in the active material of the MPFD was also confirmed to be negligible. Lastly, fission fragment energy deposition was found to be in conformance with previously reported results.

36 MATERIALS SCIENCE↗

Robustness of the smartpixels classifier for different simulated sensor geometries and non-ideal detector conditions

Pixel tracking detectors at upcoming collider experiments will see unprecedented charged-particle densities. Real-time data reduction on the detector will enable higher granularity and faster readout, possibly enabling the use of the pixel detector in high-rate online event selection, such as the ATLAS or CMS first-level trigger systems. This data reduction can be accomplished with a neural network (NN) in the readout chip bonded with the sensor that recognizes and rejects tracks with low transverse momentum (p T ) based on the geometrical shape of the charge deposition (“cluster”). To design viable detectors for deployment, the dependence of the NN as a function of the sensor geometry, external magnetic field, irradiation, and noise must be understood. In this paper, we present first studies of the efficiency and data reduction for planar pixel sensors exploring these parameters. For the CMS HL-LHC sensor geometry, we obtain a signal efficiency of (91.9 ± 0.7)% and a data reduction of (29.7 ± 1.0)%. A smaller sensor pitch in the bending direction improves the p T discrimination, but a larger pitch can be partially compensated with detector thickness. Any accumulated radiation damage also changes the cluster shape, reducing the signal efficiency compared to the baseline by approximately 30–60% in absolute terms, but nearly all of the performance can be recovered through retraining of the network and updating the weights. Finally, the impact of noise was investigated, and retraining the network on noise-injected datasets was found to maintain performance within 6% of the baseline network trained and evaluated on noiseless data. •ASIC-compatible track-momentum classifier is robust in realistic detector conditions.•About 90% signal efficiency and 30% data reduction per layer for CMS HL-LHC geometry.•Single-layer signal efficiency increases for smaller pixel pitch or thicker sensors.•Performance with noise or after radiation damage mostly recovered by retraining.

Shekar, Danush [Illinois U., Chicago] (ORCID:00000↗

FastDIRC: a fast Monte Carlo and reconstruction algorithm for DIRC detectors

FastDIRC is a novel fast Monte Carlo and reconstruction algorithm for DIRC detectors. A DIRC employs rectangular fused-silica bars both as Cherenkov radiators and as light guides. Cherenkov-photon imaging and time-of-propagation information are utilized by a DIRC to identify charged particles. GEANT4-based DIRC Monte Carlo simulations are extremely CPU intensive. The FastDIRC algorithm permits fully simulating a DIRC detector more than 10,000 times faster than using GEANT4. This facilitates designing a DIRC-reconstruction algorithm that improves the Cherenkov-angle resolution of a DIRC detector by ≈ 30% compared to existing algorithms. FastDIRC also greatly reduces the time required to study competing DIRC-detector designs.

47 OTHER INSTRUMENTATION↗

Late Prompt Fission Gamma Rays from 235 U(n,f) and 252 Cf(sf)

Two measurements of fission γ rays were performed with the DANCE and NEUANCE arrays using the reactions 235 U(n, f) and 252 Cf(sf). Utilizing the fast time response of the detectors and a method for estimating the accidental background, we obtained the energy spectrum of the late prompt fission γ rays as a function of the time since fission. The experimental results are compared with predictions of the code CGMF folded with GEANT4 simulations of the detector response.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Real-Time event reconstruction for Nuclear Physics Experiments using Artificial Intelligence

Charged track reconstruction is a critical task in nuclear physics experiments, enabling the identification and analysis of particles produced in high-energy collisions. Machine learning (ML) has emerged as a powerful tool for this purpose, addressing the challenges posed by complex detector geometries, high event multiplicities, and noisy data. Traditional methods rely on pattern recognition algorithms like the Kalman filter, but ML techniques, such as neural networks, graph neural networks (GNNs), and recurrent neural networks (RNNs), offer improved accuracy and scalability. By learning from simulated and real detector data, ML models can identify and classify tracks, predict trajectories, and handle ambiguities caused by overlapping or missing hits. Moreover, ML-based approaches can process data in near-real-time, enhancing the efficiency of experiments at large-scale facilities like the Large Hadron Collider (LHC) and Jefferson Lab (JLAB). As detector technologies and computational resources evolve, ML-driven charged track reconstruction continues to push the boundaries of precision and discovery in nuclear physics. In these proceedings, we highlight advancements in charged track identification leveraging Artificial Intelligence within the CLAS12 detector, achieving a notable enhancement in experimental statistics compared to traditional methods. Additionally, we showcase real-time event reconstruction capabilities, including the inference of charged particle properties, such as momentum, direction, and species identification, at speeds matching data acquisition rates. These innovations enable the extraction of physics observables directly from the experiment in real-time.

Gavalian, Gagik (ORCID:0000000267385457)↗

Computer simulation study of multiple germanium gamma-ray sensor arrays

Design studies of large high resolution gamma-ray spectrometer systems employing multiple sensors are greatly facilitated by the use of computer simulation techniques. A study has been made by interfacing a detector geometry code with the EGS-3 version of the Stanford Linear Accelerator Center Monte-Carlo Code which has been modified to run on our VAX computer. The detector responses have been simulated for input photons with energies between 0.1 and 10 MeV. Examples are given to illustrate the performance of complex sensor arrays with different configurations of the anticoincidence system. Of particular interest is a design composed of an array of 7 detector elements each consisting of a thin planar Ge (1 cm thick) detector mounted in front of and in tandem with a large coaxial Ge detector.

Nakano, G. H.↗

Calibration of the Large Area X-Ray Proportional Counter (LAXPC) Instrument on board AstroSat

We present the calibration and background model for the Large Area X-ray Proportional Counter (LAXPC) detectors on board AstroSat . The LAXPC instrument has three nominally identical detectors to achieve a large collecting area. These detectors are independent of each other, and in the event analysis mode they record the arrival time and energy of each photon that is detected. The detectors have a time resolution of 10 μ s and a dead-time of about 42 μ s. This makes LAXPC ideal for timing studies. The energy resolution and peak channel-to-energy mapping were obtained from calibration on the ground using radioactive sources coupled with GEANT4 simulations of the detectors. The response matrix was further refined from observations of the Crab after launch. At around 20 keV the energy resolution of the detectors is 10%–15%, while the combined effective area of the three detectors is about 6000 cm{sup 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the performance of a large scale water-Cherenkov detector (MEMPHYS)

MEMPHYS (MEgaton Mass PHYSics) is a proposed large-scale water Cherenkov experiment to be performed deep underground. It is dedicated to nucleon decay searches, neutrinos from supernovae, solar and atmospheric neutrinos, as well as neutrinos from a future Super-Beam or Beta-Beam to measure the CP violating phase in the leptonic sector and the mass hierarchy. A full simulation of the detector has been performed to evaluate its performance for beam physics. The results are given in terms of ''migration matrices'' of reconstructed versus true neutrino energy, taking into account all the experimental effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for 2{nu}{beta}{beta} Decay of {sup 130}Te to the First Excited State of {sup 130}Xe with an Ultra-Low-Background Germanium Crystal Array

The goal of searching for zero-neutrino double-beta (0{nu}{beta}{beta}) decay is to probe an absolute neutrino mass scale suggested by the mass-splitting parameters observed by neutrino oscillation experiments. Furthermore, observation of 0{nu}{beta}{beta} decay is an explicit instance of Lepton-number non-conservation. A sensitive measurement of two-neutrino double-beta (2{nu}{beta}{beta}) decay can provide critical input to Quasiparticle Random Phase Approximation (QRPA) calculations of the nuclear matrix elements in models similar to those used to extract the absolute neutrino mass from (0{nu}{beta}{beta}) decay experiments. Tellurium-130, an even-even nucleus, can undergo 2{nu}{beta}{beta} decay to the first 0+ excited state of {sup 130}Xe producing three possible {gamma}-ray cascades as it transitions to the ground state. The Cascades detector is a high purity germanium (HPGe) crystal array consisting of two ultra-low-background copper cryostats each housing a hexagonal array of seven crystals. The project is currently being developed at Pacific Northwest National Laboratory in Richland, WA (USA), and aims to obtain very high {gamma}-ray detection efficiency while utilizing highly effective and low-background shielding. GEANT4 simulations of the detector are performed for a {sup 130}Te sample in order to determine the optimum size and geometry of the source for maximum detection efficiency and predict its sensitivity for measuring 2{nu}{beta}{beta} decay to the first 0+ excited state of {sup 130}Xe. These simulations are validated with calibration sources and presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗