Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffraction pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Characterization of sub-micrometre-sized voids in fixed human brain tissue using scanning X-ray microdiffraction

Using a 5 µm-diameter X-ray beam, we collected scanning X-ray microdiffraction in both the small-angle (SAXS) and the wide-angle (WAXS) regimes from thin sections of fixed human brain tissue from Alzheimer's subjects. The intensity of scattering in the SAXS regime of these patterns exhibits essentially no correlation with the observed intensity in the WAXS regime, indicating that the structures responsible for these two portions of the diffraction patterns, which reflect different length scales, are distinct. SAXS scattering exhibits a power-law behavior in which the log of intensity decreases linearly with the log of the scattering angle. The slope of the log–log curve is roughly proportional to the intensity in the SAXS regime and, surprisingly, inversely proportional to the intensity in the WAXS regime. We interpret these observations as being due to the presence of sub-micrometre-sized voids formed during dehydration of the fixed tissue. The SAXS intensity is due largely to scattering from these voids, while the WAXS intensity derives from the secondary structures of macromolecular material surrounding the voids. The ability to detect and map the presence of voids within thin sections of fixed tissue has the potential to provide novel information on the degradation of human brain tissue in neurodegenerative diseases.

Chemistry↗

The crystalline phases present in carbon cathodes of discharged Li/SOCl2-LiAlCl4 cells

The X-ray diffraction patterns of 100 percent discharged Schawinigan black cathodes from Li/SOCl2-LiAlCl4 cells were obtained using a high resolution Guinier camera. The previous assignments of the diffraction lines to Li2O2 and rhombohedral sulfur are all found to be incorrect; all sharp Bragg diffraction lines not assignable to anhydrous LiCl can be assigned to LiCl.H2O.

Williams, R. M.↗

What is an ‘ideally imperfect’ crystal? Is kinematical theory appropriate?

The diffraction from imperfect crystals and the applicability of kinematical theory are described. Most materials are crystalline because atoms and molecules tend to form ordered arrangements, and since the interatomic distances are comparable with the wavelength of X-rays, their interaction creates diffraction patterns. The intensity in these patterns changes with crystal quality. Perfect crystals, e.g. semiconductors, fit well to dynamical theory, whereas crystals that reveal the stereochemistry of complex biological molecules, the structure of organic and inorganic molecules and powders are required to be fragmented (termed ‘ideally imperfect’) to justify the use of the simpler kinematical theory. New experimental results of perfect and imperfect crystals are interpreted with a fundamental description of diffraction, which does not need fragmented crystals but just ubiquitous defects. The distribution of the intensity is modified and can influence the interpretation of the patterns.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-resolution three-dimensional structural microscopy by single-angle Bragg ptychography

Coherent X-ray microscopy by phase retrieval of Bragg diffraction intensities enables lattice distortions within a crystal to be imaged at nanometre-scale spatial resolutions in three dimensions. While this capability can be used to resolve structure–property relationships at the nanoscale under working conditions, strict data measurement requirements can limit the application of current approaches. Here, in this work, we introduce an efficient method of imaging three-dimensional (3D) nanoscale lattice behaviour and strain fields in crystalline materials with a methodology that we call 3D Bragg projection ptychography (3DBPP). This method enables 3D image reconstruction of a crystal volume from a series of two-dimensional X-ray Bragg coherent intensity diffraction patterns measured at a single incident beam angle. Structural information about the sample is encoded along two reciprocal-space directions normal to the Bragg diffracted exit beam, and along the third dimension in real space by the scanning beam. Finally, we present our approach with an analytical derivation, a numerical demonstration, and an experimental reconstruction of lattice distortions in a component of a nanoelectronic prototype device.

36 MATERIALS SCIENCE↗

Toward accurate measurement of electromagnetic field by retrieving and refining the center position of non-uniform diffraction disks in Lorentz 4D-STEM

Recent advancement in scanning transmission electron microscopy (STEM) allows the use of 4D-STEM, a technique that captures an electron diffraction pattern at each scan point in STEM, to measure electrostatic and magnetic potential and field in materials. However, accurate measurement, separation of the magnetic and electric signals, and removal of artifacts remain challenging, especially in the presence of complex non-uniform diffraction contrast within the disks. In this work, based on dynamic simulations of 4D-STEM patterns built upon superstructures consisting of millions of atoms to account for different sample thickness and edge geometries, we show how the shape and intensity distribution of the central disk are affected by multiple scattering. We propose a robust refinement procedure through iteration of the spin-sensitive peak position of the disk-center in the circular Hough transform filtered images from experimental Lorentz 4D-STEM dataset after minimizing the possible artifacts, such as those due to the change of thickness, dynamic scattering, and scanning process. We verify that caution must be taken as in practice the rigid-disk-shift model used to reconstruct induction maps can easily break down due to disk-protrusion when there exists a nonconstant phase gradient or thickness within the width of the probe. Through quantitative analysis and comparing experiment with calculation the effect of the non-spin-related intensity distribution inside the disk as well as that causes the disk shift due to the intensity-protrusion can be removed, and high-quality magnetic field mapping is possible.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Light Scattering for Thermometry of Fermionic Atoms in an Optical Lattice

We propose a method of using off-resonant light scattering to measure the temperature of fermionic atoms tightly confined in a two-dimensional optical-lattice potential. We show that fluctuations of the intensity in the far-field diffraction pattern arising from thermal correlations of the atoms can be accurately detected above the shot noise by collecting photons scattered in a forward direction, with the diffraction maxima blocked. The sensitivity of this method of thermometry is enhanced by an additional harmonic trapping potential.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stream pattern analysis using optical processing of ERTS imagery of Kansas

A spatial frequency analysis was carried out to obtain large-scale geologic and other ground pattern spatial frequency and orientational data from an optical data processing system using Earth Resources Technology Satellite-1 (ERTS-1) imagery of Kansas as input. The Diffraction Pattern Sampling Unit (DPSU) of the optical data processing system consists of a photodiode array containing 32 wedge-shaped photodiodes and 32 annular ring diodes. The curve obtained from the intensity distribution of the frequency spectrum yielded by the ring diodes gives the spatial frequency contributions due to ground features on the image. The curve obtained from the wedge-shaped diodes indicates the orientation of features in the sample area. Ten sample sites were used for each of eight geologic-physiographic regions. Comparison of ERTS-1 images with their respective spatial frequency and orientational curves reveals that preferred orientations of drainage produce recognizable peaks.

Mccauley, J.↗

A reference-area-free strain mapping method using precession electron diffraction data

Here, in this work, we developed a method using precession electron diffraction data to map the residual elastic strain at the nano-scale. The diffraction pattern of each pixel was first collected and denoised. Template matching was then applied using the center spot as the mask to identify the positions of the diffraction disks. Statistics of distances between the selected diffracted disks enable the user to make an informed decision on the reference and to generate strain maps. Strain mapping on an unstrained single crystal sapphire shows the standard deviation of strain measurement is 0.5%. With this method, we were able to successfully measure and map the residual elastic strain in VO 2 on sapphire and martensite in a Ni 50.3 Ti 29.7 Hf 20 shape memory alloy. This approach does not require the user to select a “strain-free area” as a reference and can work on datasets even with the crystals oriented away from zone axes. This method is expected to provide a robust and more accessible alternative means of studying the residual strain of various material systems that complements the existing algorithms for strain mapping.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesis of cerium oxide (CeO 2 ) by co-precipitation for application as a reference material for X-ray powder diffraction peak widths

Several methods can be used to obtain, from powder diffraction patterns, crystallite size and lattice strain of polycrystalline samples. Some examples are the Scherrer equation, Williamson–Hall plots, Warren/Averbach Fourier decomposition, Whole Powder Pattern Modeling, and Debye function analysis. To apply some of these methods, it is necessary to remove the contribution of the instrument to the widths of the diffraction peaks. Nowadays, one of the main samples used for this purpose is the LaB6 SRM660b commercialized by the National Institute of Standard Technology; the width of the diffraction peak of this sample is caused only by the instrumental apparatus. However, this sample can be expensive for researchers in developing countries. In this work, the authors present a simple route to obtain micron-sized polycrystalline CeO 2 that have a full width at half maximum comparable with the SRM660b and therefore it can be used to remove instrumental broadening.

de Lima Batista, Anderson Márcio↗

Higher Dimensionality in the Mg–Co–B System: Synthesis and Structure of Incommensurate Composite Mg 1+ε Co 4 B 4

Guided by high-temperature in situ X-ray diffraction, the discovery and synthesis of Mg 1+ε Co 4 B 4 (ε ≈ 0.272) using a MgH 2 hydride precursor is reported, along with a detailed crystal structure description and measurement of magnetic properties. The mismatch in lattice periodicities between Mg and Co–B substructures places Mg 1+ε Co 4 B 4 in the family of incommensurate composite crystals and prompted structural refinement in a (3 + 1)-dimensional model. The structure of Mg 1+ε Co 4 B 4 (P4 2 /ncm(00γ)s00s, a = 6.75847(7) Å, c = 3.94007(8) Å, q = (0, 0, 1.2721(3))) was refined from neutron powder diffraction and high-resolution powder X-ray diffraction data and confirmed by scanning transmission electron microscopy and electron diffraction. Mg 1+ε Co 4 B 4 is isostructural to Nd 1+ε Fe 4 B 4 and several related ternary borides with 0.07 ≤ ε ≤ 0.17, with Mg occupying the rare-earth site. Satellite reflections in the electron diffraction patterns hinted at positional modulation of the transition metal–boron substructure by Mg atoms, but this could not be refined from the neutron or X-ray diffraction data. Low-temperature magnetic measurements show no indications of long-range magnetic ordering or superconductivity down to 5 K. DFT calculations confirmed the absence of a magnetically ordered ground state and the stability of a 5:4 supercell (ε = 0.25) relative to the fully commensurate structure. Neutron diffraction and synthesis from elemental Mg demonstrated that Mg 1+ε Co 4 B 4 is not a hydrogen-stabilized phase. Mg 1+ε Co 4 B 4 represents the second compound reported in the Mg–Co–B system and the first superspace symmetry model of a Nd 1+ε Fe 4 B 4 -type incommensurate composite compound refined from powder diffraction data.

chemical structure↗

Investigations of cations distributions and morphology of cobalt ferrite magnetic nanoparticles

Cobalt ferrite nanoparticles were synthesized by co-precipitation method and structural properties was investigated by X-ray diffraction (XRD) at room temperature. X-ray diffraction data was used to determine lattice parameter, X-ray density, distributions of cations among tetrahedral and octahedral sites, site radii, ionic radii and bond length of inverse spinel cobalt ferrite. XRD analysis revealed crystallinity and high intense peak correspond to cubic inverse spinel structure with average crystalline size measured by X-ray line profile fitting was found to be 13nm for most intense peak (311). The surface morphology and microstructural feature was investigated by TEM analysis which revealed that particle size varying from 12-22 nm with selected electron diffraction pattern (SAED).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Reuniting crystallography with real space: Ab initio structure elucidation with 4D-STEM

Structure elucidation via single-crystal methods has historically lacked experimental access to real-space information, instead relying exclusively on diffraction-space measurements of Bragg reflections. Here we exploit the dual-space imaging power of 4D scanning transmission electron microscopy to meaningfully integrate real-space information into the crystallographic workflow. We show that virtual apertures assembled by segmentation of high-angle annular dark-field images enable i) pixel-by-pixel separation of coherent Bragg signal from clusters of closely spaced nanocrystals and ii) selective extraction of integrated intensities from thinner subregions of individual specimens, facilitating retroactive tuning of multiple scattering artifacts. This strategy empowers us to simply pick and choose whichever nanoscale regions of interest generate the highest-quality diffraction patterns, allowing us to solve several independent structures of the metal-organic framework UiO-66 from specimens whose agglomerated morphology proved intractable for conventional microcrystal electron diffraction. Our method is compatible with both rotational and serial approaches to data processing, ultimately divulging the first scanning nanobeam electron diffraction structures determined by direct methods at subangstrom resolution.

Saha, Ambarneil↗

Hard X-ray polarizer to enable simultaneous three-dimensional nanoscale imaging of magnetic structure and lattice strain

Recent progress in the development of dichroic Bragg coherent diffractive imaging, a new technique for simultaneous three-dimensional imaging of strain and magnetization at the nanoscale, is reported. This progress includes the installation of a diamond X-ray phase retarder at beamline 34-ID-C of the Advanced Photon Source. Here, the performance of the phase retarder for tuning X-ray polarization is demonstrated with temperature-dependent X-ray magnetic circular dichroism measurements on a gadolinium foil in transmission and on a Gd 5 Si 2 Ge 2 crystal in diffraction geometry with a partially coherent, focused X-ray beam. Feasibility tests for dichroic Bragg coherent diffractive imaging are presented. These tests include (1) using conventional Bragg coherent diffractive imaging to determine whether the phase retarder introduces aberrations using a nonmagnetic gold nanocrystal as a control sample, and (2) collecting coherent diffraction patterns of a magnetic Gd 5 Si 2 Ge 2 nanocrystal with left- and right-circularly polarized X-rays. Future applications of dichroic Bragg coherent diffractive imaging for the correlation of strain and lattice defects with magnetic ordering and inhomogeneities are considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging single cells in a beam of live cyanobacteria with an X-ray laser (CXIDB ID 27)

Diffraction pattern of a micron-sized S. elongatus cell at 1,100 eV photon energy (1.13 nm wavelength) with ~10^11 photons per square micron on the sample in ~70 fs. The signal to noise ratio at 4 nm resolution is 3.7 with 0.24 photons per Nyquist pixel. The cell was alive at the time of the exposure. The central region of the pattern (dark red) is saturated and this prevented reliable image reconstruction.

AMO↗

Hair treatment process providing dispersed colors by light diffraction

A hair treatment process for providing dispersed colors by light diffraction including (a) coating the hair with a material comprising a polymer, (b) pressing the hair with a pressing device including one or more surfaces, and (c) forming a secondary nanostructured surface pattern on the hair that is complementary to the primary nanostructured surface pattern on the one or more surfaces of the pressing device. The secondary nanostructured surface pattern diffracts light into dispersed colors that are visible on the hair. The section of the hair is pressed with the pressing device for from about 1 to 55 seconds. The polymer has a glass transition temperature from about 55.degree. C. to about 90.degree. C. The one or more surfaces include a primary nanostructured surface pattern.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In situ Synchrotron X‐ray Metrology Boosted by Automated Data Analysis for Real‐time Monitoring of Cathode Calcination

Abstract Synchrotron X‐ray‐based in situ metrology is advantageous for monitoring the synthesis of battery materials, offering high throughput, high spatial and temporal resolution, and chemical sensitivity. However, the rapid generation of massive data poses a challenge to on‐site, on‐the‐fly analysis needed for real‐time process monitoring. Here, a weighted lagged cross‐correlation (WLCC) similarity approach is presented for automated data analysis, which merges with in situ synchrotron X‐ray diffraction metrology to monitor the calcination process of the archetypal nickel‐based cathode, LiNiO 2 . The WLCC approach, incorporating variables that account for peak shifts and width changes associated with structural transformations, enables rapid extraction of phase progression within 10 seconds from tens of diffraction patterns. Details are captured, from initial precursors to intermediates and the final layered LiNiO 2 , providing information for agile on‐site adjustments during experiments and complementing post hoc diffraction analysis by offering insights into early‐stage phase nucleation and growth. Expanding this data‐powered platform paves the way for real time calcination process monitoring and control, which is pivotal to quality control in battery cathode manufacturing.

36 MATERIALS SCIENCE↗

Influence of Polarization Setting on Gold Nanorod Signal at Nonplasmonic Wavelengths Under Differential Interference Contrast Microscopy

Researchers rely on a variety of microscopic techniques for observing and tracking anisotropic nanoparticles in real time experiments. This technical note focuses on the optical behavior exhibited by gold nanorods at nonplasmonic wavelengths under differential interference contrast microscopy (DIC). Intense diffraction patterns appear at nonplasmonic wavelengths, and the behavior of these patterns can be altered by adjusting the surrounding medium or the polarizer setting. Such patterns are absent when linear and crossed polarizations are utilized. Making polarization adjustments is important in DIC microscopy, because it affects bias retardation and image contrast. The nonplasmonic diffraction bands that were observed could potentially be exploited for rotational tracking, but more importantly, researchers should exhibit care in selecting a nanorod sample and the polarization setting when working with DIC microscopy.

36 MATERIALS SCIENCE↗