Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital composite”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Interplanetary medium data book

Unresolved questions on the physics of solar wind and its effects on magnetospheric processes and cosmic ray propagation were addressed with hourly averaged interplanetary plasma and magnetic field data. This composite data set is described with its content and extent, sources, limits of validity, and the mutual consistency studies and normalizations to which the input data were subjected. Hourly averaged parameters were presented in the form of digital listings and 27-day plots. The listings are contained in a separately bound appendix.

King, J. H.↗

Interpretation of HCMM images: A regional study

Potential users of HCMM data, especially those with only a cursory background in thermal remote sensing are familiarized with the kinds of information contained in the images that can be extracted with some reliability solely from inspection of such standard products as those generated at NASA/GSFC and now achieved in the National Space Science Data Center. Visual analysis of photoimagery is prone to various misimpressions and outright errors brought on by unawareness of the influence of physical factors as well as by sometimes misleading tonal patterns introduced during photoprocessing. The quantitative approach, which relies on computer processing of digital HCMM data, field measurements, and integration of rigorous mathematical models, can usually be used to identify, compensate for, or correct the contributions from at least some of the natural factors and those associated with photoprocessing. Color composite, day-IR, night-IR and visible images of California and Nevada are examined.

Source record↗

An Overview of the Current State of the Art on Small Spacecraft Avionics Systems

Small spacecraft command and data handling and flight software systems, technologies, and capabilities are continuously evolving, enabling new opportunities for developing and deploying next-generation small spacecraft avionics. When small spacecraft were first introduced, their primary purpose was to observe and send information back to Earth. As awareness and utility expands, there is a need to improve the overall capability of collecting data in a specific mission environment. Small spacecraft currently perform a wide variety of science in low-Earth orbit and are emerging as candidates for more formidable beyond low-Earth orbit missions. This paper will expand on the technological evolution of avionics systems, their requirements to meet the need for modern, complex small spacecraft missions, and the updated avionics architecture composition. The authors will also inform the readers on the current state-of-the-art in SmallSat avionics and connect decentralized avionics architecture to non-aerospace applications and its underlying role in the movement to “digitally managed everything”.

B. Yost↗

Vidicon spectral imaging - Color enhancement and digital maps

A silicon imaging photometer system (SIPS) was used to obtain visible and near-infrared spectral imaging data in four narrow bandpasses (0.38, 0.56, 0.85, and 1.05 microns) for a 400-by-400-km lunar region which includes the Serenitatis-Tranquillitatis border. Three ratio frames were used to make color composites of radio images, and spectral maps based on interactive 'cluster' analysis were produced from four video channels. A low albedo titanium-poor unit occurs near the southern edge of the Serenitatis and south of the basin; this unit appears to postdate the high-titanium dark Tranquillitatis and 'blue-ring' material and may be associated with an Al/Si anomaly noticed in Apollo orbital X-ray data.

Johnson, T. V.↗

New Insights into the Composition and Texture of Lunar Regolith Using Ultrafast Automated Electron-Beam Analysis

Sieved grain mounts of Apollo 16 drive tube samples have been examined using QEMSCAN - an innovative electron beam technology. By combining multiple energy-dispersive X-ray detectors, fully automated control, and off-line image processing, to produce digital mineral maps of particles exposed on polished surfaces, the result is an unprecedented quantity of mineralogical and petrographic data, on a particle-by-particle basis. Experimental analysis of four size fractions (500-250 microns, 150-90 microns, 75-45 microns and < 20 microns), prepared from two samples (64002,374 and 64002,262), has produced a robust and uniform dataset which allows for the quantification of mineralogy; texture; particle shape, size and density; and the digital classification of distinct particle types in each measured sample. These preliminary data show that there is a decrease in plagioclase modal content and an opposing increase in glass modal content, with decreasing particle size. These findings, together with data on trace phases (metals, sulphides, phosphates, and oxides), provide not only new insights into the make-up of lunar regolith at the Apollo 16 landing site, but also key physical parameters which can be used to design lunar simulants, and compute Figures of Merit for each material produced.

Rickman, Doug↗

RADIOACTIVE ELEMENTS IN THE STANDARD ATOMIC WEIGHTS TABLE

In the 1949 Report of the Atomic Weights Commission, a series of new elements were added to the Atomic Weights Table. Since these elements had been produced in the laboratory and were not discovered in nature, the atomic weight value of these artificial products would depend upon the production method. Since atomic weight is a property of an element as it occurs in nature, it would be incorrect to assign an atomic weight value to that element. As a result of that discussion, the Commission decided to provide only the mass number of the most stable (or longest-lived) known isotope as the number to be associated with these entries in the Atomic Weights Table. As a function of time, the mass number associated with various elements has changed as longer-lived isotopes of a particular element has been found in nature, or as improved half-life values of an element's isotopes might cause a shift in the longest-lived isotope from one mass to another. In the 1957 Report of the Atomic Weights Commission, it was decided to discontinue the listing of the mass number in the Atomic Weights Table on the grounds that the kind of information supplied by the mass number is inconsistent with the primary purpose of the Table, i.e., to provide accurate values of 'these constants' for use in various chemical calculations. In addition to the Table of Atomic Weights, the Commission included an auxiliary Table of Radioactive Elements for the first time, where the entry would be the isotope of that element which was the most stable, i.e., the one with the longest known half-life. In their 1973 Report, the Commission noted that the users of the main Table of Atomic Weights were dissatisfied with the omission of values for some elements in that Table and it was decided to reintroduce the mass number for the radioactive elements into the main Table. In their 1983 Report, the Commission decided that radioactive elements were considered to lack a characteristic terrestrial isotopic composition, from which an atomic weight value could be calculated to five or more figure accuracy, without prior knowledge of the sample involved. These elements were again listed in the Atomic Weights Table with no further information, i.e., with no mass number or atomic weight value. For the elements, which have no stable characteristic terrestrial isotopic composition, the data on the half-lives and the relative atomic masses for the nuclides of interest for those elements have been evaluated. The values of the half-lives with their uncertainties are listed in the table. The uncertainties are given for the last digit quoted of the half-life and are given in parentheses. A half-life entry for the Table having a value and an uncertainty of 7 {+-} 3 is listed in the half-life column as 7 (3). The criteria to include data in this Table, is to be the same as it has been for over sixty years. It is the same criteria, which are used for all data that are evaluated for inclusion in the Standard Table of Atomic Weights. If a report of data is published in a peer-reviewed journal, that data is evaluated and considered for inclusion in the appropriate table of the biennial report of the Atomic Weights Commission. As better data becomes available in the future, the information that is contained in either of the Tables of Standard Atomic Weights or in the Table of Radioactive Elements may be modified. It should be noted that the appearance of any datum in the Table of the Radioactive Elements is merely for the purposes of calculating an atomic mass value for any sample of a radioactive material, which might have a variety of isotopic compositions and it has no implication as to the priority for claiming discovery of a given element and is not intended to. The atomic mass values have been taken primarily from the 2003 Atomic Mass Table. Mass values for those radioisotopes that do not appear in the 2003 Atomic mass Table have been taken from preliminary data of the Atomic Mass Data Center. Most of the quoted half-lives.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uses of Computed Tomography in the NASA Materials Science Program

Computed Tomography (CT) has proved to be of inestimable use in providing a rapid evaluation of a variety of samples from Mechanics of Granular Materials (MGM) to electronic materials (Ge-Si alloys) to space grown materials such as meteorites. The system at Kennedy Space Center (KSC), because of its convenient geographical location, is ideal for examining samples immediately after returning to Earth. It also has the advantage of the choice of fluxes, and in particular the use of a radioactive cobalt source, which is basically monochromatic. This permits a reasonable measurement of density to be made from which chemical composition can be determined. Due to the current dearth of long duration space grown materials, the CT instrument has been used to characterize materials in preparation for flight, to determine thermal expansion values, and to examine long duration space grown materials, i.e. meteorites. The work will first describe the establishment of the protocol for obtaining the optimum density readings for any material. This will include both the effects of the hardware or instrumental parameters that can be controlled, and the techniques used to process the CT data. Examples will be given of the compositional variation along single crystals of germanium-silicon alloys. Density variation with temperature has been measured in preparation for future materials science experiments; this involved the fabrication and installation of a single zone furnace incorporating a heat pipe to ensure of high temperature uniformity. At the time of writing the thermal expansion of lead has been measured from room temperature to 900 C. Three methods are available. Digital radiography enable length changes to be determined. Prior to melting the sample is small than the container and the diameter change can be measured. Most critical, however, is the density change in solid, through the melting region, and in the liquid state. These data are needed for engineering purposes to aid in the design of containment cartridges, and for enabling fluid flow calculations. A second sample, with the lead alloyed with antimony is ready for scanning. This corresponds to the planned composition of Dr. Poirier's flight experiment. Finally, three-dimensional results will be shown of the structure of a two-phase metallic meteorite of metal and sulfide, in which the iron-nickel phase has coarsened during slow cooling over hundreds of millions of years.

Engel, H. Peter↗

Myna: Connecting powder bed fusion build data to simulation tools for digital twin applications

Additive manufacturing (AM), as a digital process, can generate a detailed digital thread linking a part’s design and manufacturing to its operational performance. As AM systems advance, an increasing amount of process data is stored in manufacturing databases. In principle, this data can be utilized by simulation-based digital twin approaches, such as real-time process control and asynchronous post-processing guidance. However, few tools currently exist for systematically integrating digital thread data with computational tools. Here, in this study, we propose a software package, called Myna, for connecting data from powder bed fusion processes to simulation tools. The utility of such a platform is demonstrated using build data from the Oak Ridge National Laboratory Manufacturing Demonstration Facility “Peregrine v2023-10” public dataset to automatically configure and run 54 semi-analytical 3DThesis melt pool simulations, 78 numerical Additive FOAM melt pool simulations, and 3 ExaCA microstructure simulations. The simulated, spatially registered microstructures are then compared directly with electron backscatter diffraction characterization of the corresponding as-built part locations. The resulting simulated microstructure showed variation as a function of process parameters, particularly stripe width; however, the experimental data had little variation between the microstructure texture and grain size resulting from different processing conditions. Analysis of the discrepancies suggest that it is possible a two-phase ferritic-austenitic solidification model is needed to accurately predict grain size and texture for certain stainless steel 316L feedstock compositions under powder bed fusion conditions, providing direction for future research. As illustrated here, due to the number and complexity of the simulations involved in AM process-structure–property predictions, automated methods to connect process data and simulations will remain necessary tools for testing hypotheses and implementing digital twin applications.

Knapp, Gerald L. [Oak Ridge National Laboratory (O↗

Experimental Validation of an Additively Manufactured Stiffness-Optimized Short-Fiber Reinforced Composite Clevis Joint

This effort describes experiments for the validation of the response of an additively manufactured stiffness-optimized short-fiber reinforced composite. A Direct Ink Write (DIW) method is used to additively manufacture a clevis joint plate which was designed such that its compliance would be minimized (i.e., stiffness maximized) for far-field axial loading. A unique aspect of the optimization scheme is that it accounts for manufacturing constraints, such as tool turn radius and tool path spacing. Along with the optimized clevis joint plate, additively manufactured 0°–90° and ± 45° composite plates of the same number of layers, as well as a control 0°–90° sample of resin only, were also studied. In addition to far-field load-displacement, near-field strain was monitored using digital image correlation (DIC). The results showed that the optimized plate did indeed exhibit the largest stiffness, based on far-field measurements. DIC-measured strains showed that locally the axial strain component, which is the largest, was also minimized for the optimized specimen, although the other strain components followed different trends. Furthermore, in the experiments it was seen that the optimized design exhibited a nonlinear/hysteretic behavior which is believed to be a consequence of its internal gap/cell structure. This internal structure, which results by optimized placement of material, although explicitly not accounted for in the optimization, may affect global response. Lastly, although not a part of the optimization study itself, the failure load for the optimized joint plate was also seen to be the largest of all the cases studied.

42 ENGINEERING↗

Impact of Backing Plate and Thermal Boundary Conditions for High-Speed Friction Stir Welding of 25-mm Thick Aluminum Alloy 7175-T79

Here this study demonstrates high-speed (150 mm/min) single pass friction stir butt joining of 25 mm thick aluminum alloy 7175-T79. To understand the impact of quenching and cooling rate on process responses, joint strength, and grain size distributions across the weld thickness, we performed a series of friction stir welding (FSW) trials in air and with a trailing water spray using steel and composite backing plates (BP). Welds made in air and trailing water spray exhibit significantly different hardness distributions across the nugget, heat affected zone (HAZ), and HAZ minimum hardness as evidenced by detailed microhardness mapping. The effect of trailing water spray (TWS) on joint efficiency overshadows the influence of BP composition due to the vastly different contribution to quenching. TWS also resulted in a multifaceted effect on FSW such as lowering processing temperature, increasing X and Z forces while lowering Y force, and narrow heat affecting zone. Finally, digital image correlation (DIC)-based fracture mode analysis and grain size measurements correlate with the hardness distribution.

42 ENGINEERING↗

Representation of correlation statistics functions in heterogeneous materials using layered fast spherical harmonics expansion

Statistical correlation function, including two-point function, is one of the popular methods to digitize microstructure quantitatively. This paper investigated how to represent statistical correlations using layered fast spherical harmonics expansion. A set of spherical harmonics coefficients may be used to represent the corresponding microstructures. It is applied to represent carbon nanotube composite microstructures to demonstrate how efficiently and precisely the harmonics coefficients will characterize the microstructure. This microstructure representation methodology will dramatically improve the computational efficiencies for future works in microstructure reconstruction and property prediction.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

CORRELATIONS OF QUASAR OPTICAL SPECTRA WITH RADIO MORPHOLOGY

Using the largest homogeneous quasar sample with high-quality optical spectra and robust radio morphology classifications assembled to date, we investigate relationships between radio and optical properties with unprecedented statistical power. The sample consists of 4714 radio quasars from FIRST with S{sub 20} {>=} 2 mJy and with spectra from the Sloan Digital Sky Survey (SDSS). Radio morphology classes include core-only (core), core-lobe (lobe), core-jet (jet), lobe-core-lobe (triple), and double-lobe. Electronic tables of the quasar samples, along with spectral composites for individual morphology classes, are made available. We examine the optical colors of these subsamples and find that radio quasars with core emission unresolved by FIRST (on {approx}5'' scale) have a redder color distribution than radio-quiet quasars (S{sub 20} {approx}< 1 mJy); other classes of radio quasars have optical color distributions similar to the radio-quiet quasars. This analysis also suggests that optical colors of z {approx}< 2.7 SDSS quasars are not strongly (<0.1 mag) biased blue. We show that the radio core-to-lobe flux density ratio (R) and the radio-to-optical (i-band) ratio of the quasar core (R{sub I}) are correlated, which supports the hypothesis that both parameters are indicative of line-of-sight orientation. We investigate spectral line equivalent widths (EWs) as a function of R and R{sub I}, including the O [III] narrow line doublet and the C IV {lambda}1549 and Mg II {lambda}2799 broad lines. We find that the rest EWs of the broad lines correlate positively with R{sub I} at the 4{sigma}-8{sigma} level. However, we find no strong dependence of EW on R, in contrast to previously published results. A possible interpretation of these results is that EWs of quasar emission lines increase as the line-of-sight angle to the radio-jet axis decreases. These results are in stark contrast to commonly accepted orientation-based theories, which suggest that continuum emission should increase as the angle to the radio-jet axis decreases, resulting in smaller EWs of emission lines (assumed isotropic). Finally, we observe the Baldwin effect in our sample and find that it does not depend strongly on quasar radio morphology.

79 ASTRONOMY AND ASTROPHYSICS↗

FIRST SPECTROSCOPIC EVIDENCE FOR HIGH IONIZATION STATE AND LOW OXYGEN ABUNDANCE IN Ly{alpha} EMITTERS ,

We present results from Keck/NIRSPEC and Magellan/MMIRS follow-up spectroscopy of Ly{alpha} emitters (LAEs) at z = 2.2 identified in our Subaru narrowband survey. We successfully detect H{alpha} emission from seven LAEs, and perform a detailed analysis of six LAEs free from active galactic nucleus activity, two out of which, CDFS-3865 and COSMOS-30679, have [O II] and [O III] line detections. They are the first [O II]-detected LAEs at high-z, and their [O III]/[O II] ratios and R23-indices provide the first simultaneous determinations of ionization parameter and oxygen abundance for LAEs. CDFS-3865 has a very high ionization parameter (q{sub ion}=2.5{sup +1.7}{sub -0.8} Multiplication-Sign 10{sup 8} cm s{sup -1}) and a low oxygen abundance (12+ log (O/H)=7.84{sup +0.24}{sub -0.25}) in contrast with moderate values of other high-z galaxies such as Lyman break galaxies (LBGs). COSMOS-30679 also possesses a relatively high ionization parameter (q{sub ion}=8{sup +10}{sub -4} Multiplication-Sign 10{sup 7} cm s{sup -1}) and a low oxygen abundance (12+ log (O/H)=8.18{sup +0.28}{sub -0.28}). Both LAEs appear to fall below the mass-metallicity relation of z {approx} 2 LBGs. Similarly, a low metallicity of 12 + log (O/H) < 8.4 is independently indicated for typical LAEs from a composite spectrum and the [N II]/H{alpha} index. Such high ionization parameters and low oxygen abundances can be found in local star-forming galaxies, but this extreme local population occupies only {approx}0.06% of the Sloan Digital Sky Survey spectroscopic galaxy sample with a number density {approx}100 times smaller than that of LAEs. With their high ionization parameters and low oxygen abundances, LAEs would represent an early stage of galaxy formation dominated by massive stars in compact star-forming regions. High-q{sub ion} galaxies like LAEs would produce ionizing photons efficiently with a high escape fraction achieved by density-bounded H II regions, which would significantly contribute to cosmic reionization at z > 6.

79 ASTRONOMY AND ASTROPHYSICS↗

THE COMPOSITE SPECTRUM OF STRONG Ly{alpha} FOREST ABSORBERS

We present a new method for probing the physical conditions and metal enrichment of the intergalactic medium: the composite spectrum of Ly{alpha} forest absorbers. We apply this technique to a sample of 9480 Ly{alpha} absorbers with redshift 2 < z < 3.5 identified in the spectra of 13,279 high-redshift quasars from the Sloan Digital Sky Survey (SDSS) Fifth Data Release (DR5). Absorbers are selected as local minima in the spectra with 2.4 < {tau}{sub Ly{alpha}} < 4.0; at SDSS resolution ({approx}150 km s{sup -1} FWHM), these absorbers are blends of systems that are individually weaker. In the stacked spectra, we detect seven Lyman series lines and metal lines of O VI, N V, C IV, C III, Si IV, C II, Al II, Si II, Fe II, Mg II, and O I. Many of these lines have peak optical depths of <0.02, but they are nonetheless detected at high statistical significance. Modeling the Lyman series measurements implies that our selected systems have total H I column densities N{sub Hi{approx}}10{sup 15.4} cm{sup -2}. Assuming typical physical conditions {rho}/{rho}-bar=10, T = 10{sup 4}-10{sup 4.5} K, and [Fe/H]=-2 yields reasonable agreement with the line strengths of high-ionization species, but it underpredicts the low-ionization species by two orders of magnitude or more. This discrepancy suggests that the low-ionization lines arise in dense, cool, metal-rich clumps, present in some absorption systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation doses in volume-of-interest breast computed tomography—A Monte Carlo simulation study

Purpose: Cone beam breast computed tomography (breast CT) with true three-dimensional, nearly isotropic spatial resolution has been developed and investigated over the past decade to overcome the problem of lesions overlapping with breast anatomical structures on two-dimensional mammographic images. However, the ability of breast CT to detect small objects, such as tissue structure edges and small calcifications, is limited. To resolve this problem, the authors proposed and developed a volume-of-interest (VOI) breast CT technique to image a small VOI using a higher radiation dose to improve that region’s visibility. In this study, the authors performed Monte Carlo simulations to estimate average breast dose and average glandular dose (AGD) for the VOI breast CT technique. Methods: Electron–Gamma-Shower system code-based Monte Carlo codes were used to simulate breast CT. The Monte Carlo codes estimated were validated using physical measurements of air kerma ratios and point doses in phantoms with an ion chamber and optically stimulated luminescence dosimeters. The validated full cone x-ray source was then collimated to simulate half cone beam x-rays to image digital pendant-geometry, hemi-ellipsoidal, homogeneous breast phantoms and to estimate breast doses with full field scans. 13-cm in diameter, 10-cm long hemi-ellipsoidal homogeneous phantoms were used to simulate median breasts. Breast compositions of 25% and 50% volumetric glandular fractions (VGFs) were used to investigate the influence on breast dose. The simulated half cone beam x-rays were then collimated to a narrow x-ray beam with an area of 2.5 × 2.5 cm{sup 2} field of view at the isocenter plane and to perform VOI field scans. The Monte Carlo results for the full field scans and the VOI field scans were then used to estimate the AGD for the VOI breast CT technique. Results: The ratios of air kerma ratios and dose measurement results from the Monte Carlo simulation to those from the physical measurements were 0.97 ± 0.03 and 1.10 ± 0.13, respectively, indicating that the accuracy of the Monte Carlo simulation was adequate. The normalized AGD with VOI field scans was substantially reduced by a factor of about 2 over the VOI region and by a factor of 18 over the entire breast for both 25% and 50% VGF simulated breasts compared with the normalized AGD with full field scans. The normalized AGD for the VOI breast CT technique can be kept the same as or lower than that for a full field scan with the exposure level for the VOI field scan increased by a factor of as much as 12. Conclusions: The authors’ Monte Carlo estimates of normalized AGDs for the VOI breast CT technique show that this technique can be used to markedly increase the dose to the breast and thus the visibility of the VOI region without increasing the dose to the breast. The results of this investigation should be helpful for those interested in using VOI breast CT technique to image small calcifications with dose concern.

60 APPLIED LIFE SCIENCES↗

(abstract) Transmission Electron Microscopy of Al(sub x)Ga(sub 1-x)N/SiC Multilayer Structures

The potential of wide-band-gap III-V nitrides as solar-blind ultraviolet sensors and light emitters has prompted an increasing amount of work recently, including the fabrication of the first UV sensors from as-deposited single crystal GaN. We have used high resolution transmission electron microscopy (TEM) to study the microstructure of two novel developments of wide-band-gap III-V nitrides: the growth of ultra-short period GaN/AlN super lattices (digital alloys); and the incorporation of SiC layers into Al(sub x)Ga(sub 1-x)N structures. By varying the relative periods in a GaN/AlN superlattice, it should be possible to tailor the band gap of the composite to lie between the elemental values of 365 nm for GaN and 200 nm for AlN. The group IV semiconductor, SiC, has a close lattice match (< 3%) to Al(sub x)Ga(sub 1-x)N for growth on the basal plane. Demonstration of epitaxial growth for Al(sub x)Ga(sub 1-x)N/SiC multilayers could enable an extension of direct band-gap material towards the visible.

microscopy GaN AlN semiconductor SiC↗

A Standardized Analysis Process Using Digital Image Correlation to Calculate In Situ Cladding Strain from Modified Burst Tests for Fuel Performance Code Validation

Historical data collection on nuclear fuel cladding materials has focused on generating a statistically significant amount of data to assess the material and its failure behavior. Furthermore, data generated to support material model and failure criteria development were previously posttest evaluations, so a large number of tests was required to gain new understanding. A way to expedite this process is to develop techniques capable of generating large, high-fidelity data sets from a single test with lower uncertainty or quantified uncertainty. One such example of this approach is Oak Ridge National Laboratory’s use of modified burst tests (MBTs) to analyze the mechanical behavior and failure conditions of cladding during a simulated reactivity-initiated accident (RIA). Each test incorporates digital image correlation (DIC) analysis techniques that are used to assess the accumulated strain in situ, as well as eventual cladding failure. This work has been fruitful in defining strain-to-failure conditions for materials like silicon carbide (SiC) fiber–reinforced/SiC matrix composite tubes (SiC/SiC), iron-chromium-aluminum (FeCrAl) alloy tubes, and chromium-coated Zircaloy-4 tubes. However, there are numerous DIC software available, including open-source and proprietary software. The different DIC software use various algorithms to process images and calculate displacement values. Using these different software and algorithms can lead to varying results, and perhaps larger-than-expected uncertainties. In the present study, previously published MBT data encompassing a variety of test conditions were reanalyzed with two different DIC software to assess the variance in the calculated strain results. The data consisted of SiC/SiC, FeCrAl, and chromium-coated Zircaloy-4 tubes. Plots of the calculated strains during the transient revealed good agreement between the two DIC software. The average root-mean-square errors between the two software was 0.20% strain, which is slightly larger than a previously reported error value for these tests. In conclusion, this variance in results is low enough that this analysis method can be used for code validation.

Reactivity-initiated accident↗

Digital Image Correlation Data Processing and Analysis Techniques to Enhance Test Data Assessment and Improve Structural Simulations

The NASA Shell Buckling Knockdown Factor Project (SBKF) was established in 2007 by the NASA Engineering and Safety Center (NESC) with the primary goal to develop new analysis-based buckling design factors (a.k.a. knockdown factors) and high-fidelity buckling simulations for selected launch-vehicle-like cylindrical shell structures. A series of tests are being conducted on large-scale metallic and composite cylindrical shells in order to provide validation data for these new factors and simulations. However, the validation of these new factors and simulations is quite demanding and requires test data that is commensurate with their fidelity. Traditional instrumentation, such as linear variable displacement transducers (LVDTs) and electrical-resistance strain gages serve a critical role in providing accurate displacement and strain measurements in these tests, but only allow for data to be recorded at a select number of point locations and are not sufficient to provide all the necessary validation data. Advanced measurement technologies can be used effectively to complement traditional instrumentation and gather additional data required to validate these structural simulations. In particular, three-dimensional digital image correlation (DIC) was implemented during SBKF cylinder testing to characterize the full-field displacement and strain behavior. Commercially available VIC-3DTM software and user-written data processing scripts were used to generate valuable data and insight into the complex buckling response of the cylinders that otherwise would be impossible to gather using traditional instrumentation. In addition, the measured data from DIC was used to verify measured test data obtained from other instrumentation, enhance test and analysis correlation, and help identify the root cause of anomalous test results that may have gone unexplained if only traditional instrumentation was used. Selected test results that demonstrate the use of DIC on the SBKF cylinders are presented and a portion of the data processing methods are described.

Gardner, Nathaniel W.↗