Development of the INL Thermal Energy Distribution System (TEDS) in the Modelica Eco-System for Validation and Verification

This report provides an overview on the development of the Thermal Energy Distribution System (TEDS) in the Modelica process model eco-system at Idaho National Laboratory as part of the integrated energy system initiative. Model development has led to the creation of a dynamic process model of the experimental TEDS facility housed within the Engineering Science Laboratory (ESL) at INL. The model was then used during the pre-construction phase of the experimental effort to inform experimental design (insulation requirements, bypass line placement, expected performance of components) and to test innovative control schemes prior to the initial operation. The TEDS model developed in Modelica includes the primary components of the TEDS experimental unit including: a 200kW Chromalox heater, a single-tank packed bed thermal energy storage system filled with 0.125 inch Alumina (Al 2 O 3 ), an ethylene-glycol to Therminol-66 heat exchanger, system piping, six control valves, and all associated temperature, pressure, and mass flow sensors. The model does not include nitrogen fill gas tanks, or associated overfill tanks, as these are not part of standard system control. Two simulation sets were run. The first is a five-hour test that operates as a shakedown test for the facility. This simulation puts the facility through all five potential operating modes and showcases the ability of valving, control sensors, and component controllers to meet the system demands. The second case imposes a typical summer day demand on the system from a region with mixed commercial and residential electrical needs where the generator alone cannot meet peak demand but instead requires the thermal storage unit to act as a peaking unit. Over the course of the fifteen-hour discharge cycle heat losses account for a heat loss of approximately 15°C in outlet temperature. Such heat losses would lead to a decrease in overall system efficiency and may lead to additional design changes for such designs in the future that may include a topping heater. Through commencement of this work, a systems level model of TEDS with associated control systems, sensors, piping diameters, and component capabilities has been created. This model has been utilized in the pre-experimental phase to inform system design, insulation thicknesses, and potential control schemes to operate the system effectively and safely. Once TEDS begins operation, this model will be refined, tuned, and used for validation and verification purposes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Transparent Framework for Evaluating the Effects of DGPV on Distribution System Costs

Assessing the costs and benefits of distributed photovoltaic generators (DGPV) to the power system and electricity consumers is key to determining appropriate policies, tariff designs, and power system upgrades for the modern grid. We advance understanding of this topic by providing a transparent framework, terminology, and data set for evaluating distribution system upgrade costs, line losses, and interconnection costs as a function of DGPV penetration level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement-informed Dynamic Aggregation of Distribution Systems

This paper proposes a measurement-informed dynamic aggregation methodology in order to create equivalent representations of distribution systems that are compatible with large-scale transmission analysis. By optimizing an equivalent feeder parameters using time-series measurements of active power, reactive power, and voltage at the Point of Interconnection (POI), the approach yields simplified yet dynamically accurate equivalents. Implemented in PSCAD with models of photovoltaic–battery systems, three-phase motors, and static loads, the method employs hybrid differential evolution and bounded least-squares optimization laying the foundation for for real-time state estimation and optimized sensor placement in distribution networks.

Ahmed, Kazi Ishrak [University of Tennessee, Knoxv↗

Engineering Microgrids Amid the Evolving Electrical Distribution System

Non-wires alternatives and microgrid technologies are maturing and present great opportunities for electric utilities to increase the benefits they offer to their customers. They have the potential to decrease the cost of resolving traditional electrical system loading issues, contribute to carbon emissions reductions, and improve the electrical distribution system’s resilience to extreme weather events. The authors of this manuscript present a review of the research on microgrids and their practical applications. This is leveraged with the past work of the authors of this manuscript and other authors to develop specific objectives for microgrids, practical criteria for engineers to consider when deploying microgrids, stochastic methods to optimize microgrid designs, and black start requirements. This guidance is then used for the design of actual networked microgrids being deployed with adaptive boundaries.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution System State Estimation With High Penetration of Demand Response Enabled Loads

Demand-side operations incentivize utility customers to take part in various grid services. A demand response enabled load (DREL) is a flexible grid asset that schedules electricity consumption in response to a time-of-use (TOU) energy price. Consequently, its energy profile differs from that of a conventional load that is insensitive to price. This difference may cause new challenges for distribution system state estimation (DSSE). It is well known that DSSE often needs to use pseudo-measurements based on historic load profiles to increase system observability. However, historic profiles of conventional loads are not representative of DREL behaviors. Additionally, the inaccuracy impacts DSSE results and other DSSE-dependent operations. In this paper, we propose an online pseudo-measurement generation approach for DSSE with DRELs. We formulate an optimization model to represent DRELs self-adjusting actions. Sampling-based stochastic optimization techniques are proposed to account for uncertainties in DRELs. A set of representative DREL behavior data corresponding to the samples are used to characterize DREL pseudo-measurements. Case studies with modified IEEE 123-bus test system verify the validity of the proposed work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning Behavior of Distribution System Discrete Control Devices for Cyber-Physical Security

Conventional cyber-security intrusion detection systems monitor network traffic for malicious activity and indications that an adversary has gained access to the system. The approach discussed here expands the idea of a traditional intrusion detection system within electrical power systems, specifically power distribution networks, by monitoring the physical behavior of the grid. This is achieved through the use of high-rate distribution Phasor Measurement Units (PMUs), alongside SCADA packets analysis, for the purpose of monitoring the behavior of discrete control devices. In this work we present a set of algorithms for passively learning the control logic of voltage regulators and switched capacitor banks. Upon detection of an abnormal operation, the operator is alerted and further action can be taken. Finally, the proposed learning algorithms are validated on both simulated data and on measured PMU data from a utility pilot deployment site.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cloud-based control for power distribution system

Unique systems, methods, techniques and apparatuses for cloud-based control for power distribution systems are disclosed. One exemplary embodiment is a system comprising a microprocessor-based power management system in operative communication with a plurality of buildings located remotely from the power management system and a plurality of communication interface devices provided at corresponding ones of the plurality of buildings. The power management system is structured to perform a plurality of building unit-specific optimizations, evaluate a net power demand on the electrical power grid, reduce the net power demand on the electrical power grid while minimizing disruption to the resident-defined preference parameters, and transmit to each of the plurality of interface devices the one or more additional control commands corresponding to the specific building at which each interface device is provided.

Feng, Xiaoming↗

Maui Smart Grid Demonstration Project Managing Distribution System Resources for Improved Service Quality and Reliability, Transmission Congestion Relief, and Grid Support Functions

The Maui Smart Grid Project (MSGP) is under the leadership of the Hawaii Natural Energy Institute (HNEI) of the University of Hawaii at Manoa. The project team includes Maui Electric Company, Ltd. (MECO), Hawaiian Electric Company, Inc. (HECO), Sentech (a division of SRA International, Inc.), Silver Spring Networks (SSN), Alstom Grid, Maui Economic Development Board (MEDB), University of Hawaii-Maui College (UHMC), and the County of Maui. MSGP was supported by the U.S. Department of Energy (DOE) under Cooperative Agreement Number DE-FC26-08NT02871, with approximately 50% co-funding supplied by MECO. The project was designed to develop and demonstrate an integrated monitoring, communications, database, applications, and decision support solution that aggregates renewable energy (RE), other distributed generation (DG), energy storage, and demand response technologies in a distribution system to achieve both distribution and transmission-level benefits. The application of these new technologies and procedures will increase MECO’s visibility into system conditions, with the expected benefits of enabling more renewable energy resources to be integrated into the grid, improving service quality, increasing overall reliability of the power system, and ultimately reducing costs to both MECO and its customers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Probabilistic Voltage Sensitivity Analysis to Quantify Impact of High PV Penetration on Unbalanced Distribution System

From an operational and planning perspective, it is important to quantify the impact of increasing penetration of photovoltaics on the distribution system. Most existing impact assessment studies are scenario-based where derived results are scenario specific and not generalizable. Moreover, stochasticity in the temporal behavior of spatially distributed PVs requires a large number of scenarios that increase with the size of the network and the level of penetration. Therefore, we propose a new computationally efficient analytical framework of voltage sensitivity analysis that allows for stochastic analysis of voltage change due to random changes in PV generation. We first derive an analytical approximation for voltage change at any node of the network due to change in power at other nodes in an unbalanced distribution network. The quality of this approximation is reinforced via bounds on the approximation error. Then, we derive the probability distribution of voltage change at a certain node due to random changes in power injections/consumptions at multiple locations of the network. The accuracy of the proposed PVSA is illustrated using a modified version of the IEEE 37 bus test system. As a result, the proposed PVSA can serve as a powerful tool for proactive monitoring/control and ease the computational burden associated with perturbation based cybersecurity mechanisms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data-Driven Approach for High-Impedance Fault Localization in Distribution Systems

Accurate and quick identification of high-impedance faults (HIFs) is critical for the reliable operation of distribution systems. Unlike other faults in power grids, HIFs are very difficult to detect by conventional overcurrent relays due to the low fault current. Although HIFs can be affected by various factors, the voltage-current characteristics can substantially imply how the system responds to the disturbance and thus provides opportunities to effectively localize HIFs. In this work, we propose a data-driven approach for the identification of HIF events. To tackle the nonlinearity of the voltage-current trajectory, first, we formulate optimization problems to approximate the trajectory with piecewise functions. Then we collect the function features of all segments as inputs and use the support vector machine approach to efficiently identify HIFs at different locations. Numerical studies on the IEEE 123-node test feeder demonstrate the validity and accuracy of the proposed approach for real-time HIF identification.

explainable artificial intelligence↗

LuSEE-night power distribution system design

The Lunar Surface Electromagnetic Experiment at Night (LuSEE-Night) is a low-frequency, 0.5 to 50 MHz, radio experiment on the radio-quiet far side of the Moon. The instrument will be launched by NASA Commercial Lunar Payload Services in 2026. The LuSEE-Night instrument core is composed of a radio frequency spectrometer (SPT) processing signals from four antennas, the Data Controller Board (DCB), low electromagnetic interference (EMI) Picket Fence Power Supply (PFPS), and Power Distribution Unit (PDU). The battery powers the instrument during the lunar night and stores energy harvested by the solar panel array during the lunar day. The battery charging is controlled by the Power Conditioning and Distribution Unit (PCDU). The unregulated power is supplied either by the SpaceCraft (S/C) or the battery and gets distributed to the PFPS, communication radio, heaters, and deployables through the PDU. The PFPS generates all regulated low-voltage rails using switching regulation synchronized to the LuSEE-Night clock, which ensures self-generated EMI will be confined to well-defined frequency bins. Here, we discussed the unregulated power distribution system architecture and functionality. The PDU engineering and flight modules are developed and characterized to confirm compliance with LuSEE-Night requirements. At the time of writing, all power subsystem components have been integrated into the payload.

47 OTHER INSTRUMENTATION↗

ERAD: A Graph-Based Tool for Energy Resilience Analysis of Electric Distribution Systems

Understanding the impact of extreme events on people's ability to access energy is crucial for designing resilient energy systems. In the event of a disaster, damage to the electric system and related infrastructure (e.g., downed power lines, flooded equipment, hacked communication systems, damaged roads, etc.) can impact people's access to critical services, including not just electricity but also shelter, food, healthcare, and more. There is a key need to understand such impacts better and evaluate options to improve energy resilience. The Energy Resilience Analysis for Electric Distribution Systems (ERAD) tool is a free and open-source software package designed to help researchers and decision-makers analyze and improve energy system resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilience Assessment for Distribution Systems during Hurricanes: A Learning-Based Framework

This paper presents a proactive strategy for hurricane-resilient distribution systems. It proposes a Bayesian Neural Network-based outage prediction model considering various parameters, including electrical components, and weather and environmental factors. Addressing challenges in imbalanced outage datasets, a Bias-Variance Tradeoff method is proposed. A resilience assessment model quantifies resilience indices, providing insights into system weaknesses. The approach identifies weak points and serves as a planning benchmark. Numerical results on the modified IEEE 123-node test system demonstrate effectiveness in realistic hurricane scenarios.

Vahedi, Soroush↗

Architecture for Co-Simulation of Transportation and Distribution Systems with Electric Vehicle Charging at Scale in the San Francisco Bay Area

This work describes the Grid-Enhanced, Mobility-Integrated Network Infrastructures for Extreme Fast Charging (GEMINI) architecture for the co-simulation of distribution and transportation systems to evaluate EV charging impacts on electric distribution systems of a large metropolitan area and the surrounding rural regions with high fidelity. The current co-simulation is applied to Oakland and Alameda, California, and in future work will be extended to the full San Francisco Bay Area. It uses the HELICS co-simulation framework to enable parallel instances of vetted grid and transportation software programs to interact at every model timestep, allowing high-fidelity simulations at a large scale. This enables not only the impacts of electrified transportation systems across a larger interconnected collection of distribution feeders to be evaluated, but also the feedbacks between the two systems, such as through control systems, to be captured and compared. The findings are that with moderate passenger EV adoption rates, inverter controls combined with some distribution system hardware upgrades can maintain grid voltages within ANSI C.84 range A limits of 0.95 to 1.05 p.u. without smart charging. However, EV charging control may be required for higher levels of charging or to reduce grid upgrades, and this will be explored in future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Status of the LCLS-II Cryogenic Distribution System

The LINAC Coherent Light Source II (LCLS-II) located at SLAC National Accelerator Laboratory (SLAC) in Menlo Park, CA, is a U.S. Department of Energy project tasked to design and build a world-class x-ray free-electron laser facility for scientific research. The Linac has superconducting radio frequency cryomodules that are connected to the cryogenic plant by the Cryogenic Distribution System (CDS), which consists of distribution boxes with heat exchangers and reliefs, feed caps, end caps, and surface, vertical, and bypass transfer lines. The CDS components were designed and built to specification by industry. The components have been delivered and their installation at SLAC will be discussed. The as-built relief system design will be presented, showing minimization of relief inlet pressure drops while meeting capacity requirements. The relieving flow pressure drops along the lengths of the CDS to centrally located reliefs at the distribution box were analysed to satisfy Pressure Vessel and Process Piping Code criteria to ensure relief performance. The sub-atmospheric 2 K circuit relieving approach will be discussed, which includes a three-way diverter isolation valve suitable for sub-atmospheric service. The component anchoring load design approach and installation into concrete floor will be discussed. This addresses loading, including seismic loading, along the component’s load path to floor anchoring system.

43 PARTICLE ACCELERATORS↗

Economic Evaluation of Modernization Expenditures for Electric Utility Distribution Systems: A Guide for Utility Regulators

Cost-effectiveness evaluation of potential grid modernization solutions is integral to integrated distribution system planning (IDSP). This report synthesizes and updates prior cost-effectiveness approaches identified by the U.S. Department of Energy for grid modernization investments, incorporating multi-objective decision-making. The structure of the report follows the IDSP process, from identifying objectives and priorities to prioritizing grid solutions. The report details two methods for conducting initial cost-effectiveness screening of individual and interdependent grid components: (1) Lowest Reasonable Cost and (2) Benefit-Cost Analysis. Drawing on solutions that passed the initial cost-effectiveness screen, the utility prioritizes grid solutions based on policy objectives and priorities, regulatory compliance, operational efficiencies, and other factors to develop a portfolio of distribution solutions. The utility uses multi-objective decision-making to assess each proposed expenditure against each objective and respective metric. The utility applies a weighting factor, reflecting the priority ranking of the objective, to the total numerical “score” based on the contribution of the proposed solution to addressing each objective. Ultimately, the utility ranks each expenditure from highest to lowest priority using the final score for each solution as well as its cost. The report includes examples of emerging best practices for states and utilities and a cost-effectiveness process checklist.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Protection Coordination of an Inverter Generation Based Microgrid for an Unbalanced Distribution System

In this paper we examine the protection issues that must be dealt with, to successfully operate a microgrid when the utility experiences a grid outage. Changes in fault current levels within microgrids under grid-tied and islanded conditions present challenges to developing robust and reliable protection schemes. These schemes must provide an effective response in both grid-connected and islanded mode and the transition between these modes. In this study, a section of an actual residential community located in the western part of the United States (U.S.) was considered as part of the microgrid evaluation. A sizing analysis was conducted to select the appropriate sizes of DER; simulated using DER-CAM analysis. The two DERs considered for the study included solar PV and Battery Energy Storage System (BESS). This paper highlights the protection coordination issues when an existing unbalanced distribution system encompassing a residential subdivision is converted into a microgrid with generation sources with low fault contribution. It further explains the strategy to coordinate protection devices during grid connected and islanded microgrid operating regimes.