Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

High precision tilt stage as a key element to a universal test mirror for characterization and calibration of slope measuring instruments

The ultimate performance of surface slope metrology instrumentation, such as long trace profilers and auto-collimator based deflectometers, is limited by systematic errors that are increased when the entire angular range is used for metrology of significantly curved optics. At the ALS X-Ray Optics Laboratory, in collaboration with the HZB/BESSY-II and PTB (Germany) metrology teams, we are working on a calibration method for deflectometers, based on a concept of a universal test mirror (UTM) [V. V. Yashchuk et al., Proc. SPIE 6704, 67040A (2007)]. Potentially, the UTM method provides high performance calibration and accounts for peculiarities of the optics under test (e.g., slope distribution) and the experimental arrangement (e.g., the distance between the sensor and the optic under test). At the same time, the UTM calibration method is inherently universal, applicable to a variety of optics and experimental arrangements. In this work, we present the results of tests with a key component of the UTM system, a custom high precision tilt stage, which has been recently developed in collaboration with Physik Instrumente, GmbH. The tests have demonstrated high performance of the stage and its capability (after additional calibration) to provide angular calibration of surface slope measuring profilers over the entire instrumental dynamic range with absolute accuracy better than 30 nrad. The details of the stage design and tests are presented. We also discuss the foundation of the UTM method and calibration algorithm, as well as the possible design of a full scale UTM system.

47 OTHER INSTRUMENTATION↗

Early science with the Korean VLBI network: evaluation of system performance

We report the very long baseline interferometry (VLBI) observing performance of the Korean VLBI Network (KVN). The KVN is the first millimeter-dedicated VLBI network in East Asia. The KVN consists of three 21 m radio telescopes with baseline lengths in a range of 305-476 km. The quasi-optical system equipped on the antennas allows simultaneous observations at 22, 43, 86, and 129 GHz. The first fringes of the KVN were obtained at 22 GHz on 2010 June 8. Test observations at 22 and 43 GHz on 2010 September 30 and 2011 April 4 confirmed that the full cycle of VLBI observations works according to specification: scheduling, antenna control system, data recording, correlation, post-correlation data processing, astrometry, geodesy, and imaging analysis. We found that decorrelation due to instability in the hardware at times up to 600 s is negligible. The atmosphere fluctuations at KVN baseline are partly coherent, which allows us to extend integration time under good winter weather conditions up to 600 s without significant loss of coherence. The post-fit residuals at KVN baselines do not exhibit systematic patterns, and the weighted rms of the residuals is 14.8 ps. The KVN is ready to image compact radio sources both in snapshot and full-track modes with residual noise in calibrated phases of less than 2 deg at 22 and 43 GHz and with dynamic ranges of ∼300 for snapshot mode and ∼1000 for full-track mode. With simultaneous multi-frequency observations, the KVN can be used to make parsec-scale spectral index maps of compact radio sources.

79 ASTRONOMY AND ASTROPHYSICS↗

WIPP Certification of the Retrieval Box Assay System at the Advanced Mixed Waste Treatment Plant, Idaho - 16241

The Retrieval Box Assay System (RBAS) at the Advanced Mixed Waste Treatment Plant (AMWTP) is an Imaging Passive Active Neutron system supplemented with a High Purity Germanium (HPGe) gamma system for the quantification of Pu-239 Fissile Gram Equivalent (FGE) and transuranic (TRU) alpha activity of waste containers of various sizes up to 249 cm x 149 cm x 198 cm (Length x Width x Height). The system was originally calibrated in 2002 (with a range of surrogate matrices and radioactive sources in a 213 cm x 122 cm x 122 cm FRP box) and has been operational for over a decade. As of August 2015, the RBAS has measured approximately 18,000 boxes (50,000 m3 of waste) which has subsequently been fed into the facility's treatment process. Its success, and the wide envelope of waste that it can characterize, has led AMWTP to extend the RBAS mission to include WIPP certification. As part of this new project, the instrument must be capable of meeting WIPP's Waste Acceptance Criteria (WAC) which include reporting activities and masses of the 10 WIPP-tracked radionuclides. The system will be required to assay sludge and debris waste streams, shredded waste and large metal items. The container size includes Standard Waste Box (SWBs), Fiberglass Reinforced Plywood (FRPs) and large Shredder Boxes. Sludge matrices will be loaded into 210-liter (55-gallon) drums and placed inside an SWB. After assay, boxes will be over-packed into SLB-II's for shipment to WIPP. The target waste streams will contain mixtures of Weapons Grade plutonium, Heat Source plutonium (high in Pu-238 content) and Mixed Oxide (MOX). The activity of the waste is expected to encompass a wide dynamic range of activity from low-level waste (LLW) to TRU with up to several hundred grams of plutonium. Some packages will have high gamma activity associated with fission and activation products such as Cs-137 and Co-60. The existing RBAS hardware (detectors, electronics, assay chamber etc.) was retained for this project. Two lead filters were provided and installed on the existing filter wheels to attenuate the gamma ray flux from the highest activity boxes to avoid overload of the HPGe detectors. The new software suite includes PC-FRAM (Version 5), which is used for the isotopic analysis of the gamma spectra. Integration of FRAM and neutron results is performed using a software package known as RBAS WIPP Analysis Reporting Software (RWARS). This package also performs matrix dependent background adjustments. Other upgrades provided include automated tests that identify when assay parameters fall outside a predetermined range and a new Quality Checking (QC) application. Minimum Detectable Activity (MDA) values were determined for the active and passive neutron modes as a function of measured matrix correction indices. The resulting Minimum Detectable Concentration (MDC) has been demonstrated to be less than 3700 Bq/g alpha activity (100 nCi/g). Modifications were performed to update the system TMU parameters to accommodate assay of non-standard size boxes and a wider range of matrix materials. A series of calibration confirmation, measurements were performed on site in 2014 using a representative range of surrogate boxes and radioactive sources including Pu. The WIPP WAC performance criteria were successfully demonstrated up to 157 g Pu and the system passed its first Performance Demonstration Program (PDP) cycle in the Spring of 2015. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Gemini NICI planet-finding campaign: the orbit of the young exoplanet β Pictoris b

We present new astrometry for the young (12-21 Myr) exoplanet β Pictoris b taken with the Gemini/NICI and Magellan/MagAO instruments between 2009 and 2012. The high dynamic range of our observations allows us to measure the relative position of β Pic b with respect to its primary star with greater accuracy than previous observations. Based on a Markov Chain Monte Carlo analysis, we find the planet has an orbital semi-major axis of 9.1{sub −0.5}{sup +5.3} AU and orbital eccentricity <0.15 at 68% confidence (with 95% confidence intervals of 8.2-48 AU and 0.00-0.82 for semi-major axis and eccentricity, respectively, due to a long narrow degenerate tail between the two). We find that the planet has reached its maximum projected elongation, enabling higher precision determination of the orbital parameters than previously possible, and that the planet's projected separation is currently decreasing. With unsaturated data of the entire β Pic system (primary star, planet, and disk) obtained thanks to NICI's semi-transparent focal plane mask, we are able to tightly constrain the relative orientation of the circumstellar components. We find the orbital plane of the planet lies between the inner and outer disks: the position angle (P.A.) of nodes for the planet's orbit (211.8 ± 0.°3) is 7.4σ greater than the P.A. of the spine of the outer disk and 3.2σ less than the warped inner disk P.A., indicating the disk is not collisionally relaxed. Finally, for the first time we are able to dynamically constrain the mass of the primary star β Pic to 1.76{sub −0.17}{sup +0.18} M {sub ☉}.

79 ASTRONOMY AND ASTROPHYSICS↗

Very large array observations of ammonia in high-mass star formation regions

We report systematic mapping observations of the NH{sub 3} (1, 1) and (2, 2) inversion lines toward 62 high-mass star-forming regions using the Very Large Array (VLA) in its D and DnC array configurations. The VLA images cover a spatial dynamic range from 40'' to 3'', allowing us to trace gas kinematics from ∼1 pc scales to ≲0.1 pc scales. Based on the NH{sub 3} morphology and the infrared nebulosity on 1 pc scales, we categorize three subclasses in the sample: filaments, hot cores, and NH{sub 3}-dispersed sources. The ubiquitous gas filaments found on 1 pc scales have a typical width of ∼0.1 pc and often contain regularly spaced fragments along the major axis. The spacing of the fragments and the column densities is consistent with the turbulent supported fragmentation of cylinders. Several sources show multiple filaments that converge toward a center where the velocity field in the filaments is consistent with gas flows. We derive rotational temperature maps for the entire sample. For the three hot core sources, we find a projected radial temperature distribution that is best fit by power-law indices from –0.18 to –0.35. We identify 174 velocity-coherent ∼0.1 pc scale dense cores from the entire sample. The mean physical properties for these cores are 1.1 km s{sup –1} in intrinsic linewidth, 18 K in NH{sub 3} rotational temperature, 2.3 × 10{sup 15} cm{sup –2} in NH{sub 3} gas column density, and 67 M{sub ☉} in molecular mass. The dense cores identified from the filamentary sources are closer to being virialized. Dense cores in the other two categories of sources appear to be dynamically unstable.

79 ASTRONOMY AND ASTROPHYSICS↗

The role of stellar feedback in the dynamics of H II regions

Stellar feedback is often cited as the biggest uncertainty in galaxy formation models today. This uncertainty stems from a dearth of observational constraints as well as the great dynamic range between the small scales (≲1 pc) where the feedback originates and the large scales of galaxies (≳1 kpc) that are shaped by this feedback. To bridge this divide, in this paper we aim to assess observationally the role of stellar feedback at the intermediate scales of H II regions (∼10-100 pc). In particular, we employ multiwavelength data to examine several stellar feedback mechanisms in a sample of 32 H II regions (with ages ∼3-10 Myr) in the Large and Small Magellanic Clouds, respectively. Using optical, infrared, radio, and X-ray images, we measure the pressures exerted on the shells from the direct stellar radiation, the dust-processed radiation, the warm ionized gas, and the hot X-ray-emitting gas. We find that the warm ionized gas dominates over the other terms in all of the sources, although two have comparable dust-processed radiation pressures to their warm gas pressures. The hot gas pressures are comparatively weak, while the direct radiation pressures are one to two orders of magnitude below the other terms. We discuss the implications of these results, particularly highlighting evidence for hot gas leakage from the H II shells and regarding the momentum deposition from the dust-processed radiation to the warm gas. Furthermore, we emphasize that similar observational work should be done on very young H II regions to test whether direct radiation pressure and hot gas can drive the dynamics at early times.

79 ASTRONOMY AND ASTROPHYSICS↗

The energy landscape of glassy dynamics on the amorphous hafnium diboride surface

Direct visualization of the dynamics of structural glasses and amorphous solids on the sub-nanometer scale provides rich information unavailable from bulk or conventional single molecule techniques. We study the surface of hafnium diboride, a conductive ultrahigh temperature ceramic material that can be grown in amorphous films. Our scanning tunneling movies have a second-to-hour dynamic range and single-point current measurements extend that to the millisecond-to-minute time scale. On the a-HfB{sub 2} glass surface, two-state hopping of 1–2 nm diameter cooperatively rearranging regions or “clusters” occurs from sub-milliseconds to hours. We characterize individual clusters in detail through high-resolution (<0.5 nm) imaging, scanning tunneling spectroscopy and voltage modulation, ruling out individual atoms, diffusing adsorbates, or pinned charges as the origin of the observed two-state hopping. Smaller clusters are more likely to hop, larger ones are more likely to be immobile. HfB{sub 2} has a very high bulk glass transition temperature T{sub g}, and we observe no three-state hopping or sequential two-state hopping previously seen on lower T{sub g} glass surfaces. The electronic density of states of clusters does not change when they hop up or down, allowing us to calibrate an accurate relative z-axis scale. By directly measuring and histogramming single cluster vertical displacements, we can reconstruct the local free energy landscape of individual clusters, complete with activation barrier height, a reaction coordinate in nanometers, and the shape of the free energy landscape basins between which hopping occurs. The experimental images are consistent with the compact shape of α-relaxors predicted by random first order transition theory, whereas the rapid hopping rate, even taking less confined motion at the surface into account, is consistent with β-relaxations. We make a proposal of how “mixed” features can show up in surface dynamics of glasses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Relativistic nuclear energy density functionals: Adjusting parameters to binding energies

We study a particular class of relativistic nuclear energy density functionals in which only nucleon degrees of freedom are explicitly used in the construction of effective interaction terms. Short-distance (high-momentum) correlations, as well as intermediate- and long-range dynamics, are encoded in the medium (nucleon-density) dependence of the strength functionals of an effective interaction Lagrangian. Guided by the density dependence of microscopic nucleon self-energies in nuclear matter, a phenomenological ansatz for the density-dependent coupling functionals is accurately determined in self-consistent mean-field calculations of binding energies of a large set of axially deformed nuclei. The relationship between the nuclear matter volume, surface, and symmetry energies and the corresponding predictions for nuclear masses is analyzed in detail. The resulting best-fit parametrization of the nuclear energy density functional is further tested in calculations of properties of spherical and deformed medium-heavy and heavy nuclei, including binding energies, charge radii, deformation parameters, neutron skin thickness, and excitation energies of giant multipole resonances.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Metrology for Industry for use in the Manufacture of Grazing Incidence Beam Line Mirrors

The goal of this SBIR was to determine the slope sensitivity of Specular Reflection Deflectometry (SRD) and whether shearing methods had the sensitivity to be able to separate errors in the test equipment from slope error in the unit under test (UUT), or mirror. After many variations of test parameters it does not appear that SRD yields results much better than 1 μ radian RMS independent of how much averaging is done. Of course, a single number slope sensitivity over the full range of spatial scales is not a very insightful number in the same sense as a single number phase or height RMS value in interferometry does not tell the full story. However, the 1 μ radian RMS number is meaningful when contrasted with a sensitivity goal of better than 0.1 μ radian RMS. Shearing is a time proven method of separating the errors in a measurement from the actual shape of a UUT. It is accomplished by taking multiple measurements while moving the UUT relative to the test instrument. This process makes it possible to separate the two errors sources but only to a sensitivity of about 1 μ radian RMS. Another aspect of our conclusions is that this limit probably holds largely independent of the spatial scale of the test equipment. In the proposal for this work it was suggested that a test screen the full size of the UUT could be used to determine the slopes on scales of maybe 0.01 to full scale of the UUT while smaller screens and shorter focal length lenses could be used to measure shorter, or smaller, patches of slope. What we failed to take into consideration was that as the scale of the test equipment got smaller so too did the optical lever arm on which the slope was calculated. Although we did not do a test with a shorter focal length lens over a smaller sample area it is hard to argue with the logic that the slope sensitivity will be about the same independent of the spatial scale of the measurement assuming the test equipment is similarly scaled. On a more positive note, SRD does appear to be a highly flexible, easy to implement, rather inexpensive test for free form optics that require a dynamic range that exceeds that of interferometry. These optics are quite often specified to have more relaxed slope errors, on the order of 1 μ radian RMS or greater. It would be shortsighted to not recognize the value of this test method in the bigger picture.

47 OTHER INSTRUMENTATION↗

Mass Spectrometry-based Assay for High Throughput and High Sensitivity Biomarker Verification

Searching for disease specific biomarkers has become a major undertaking in the biomedical research field as the effective diagnosis, prognosis and treatment of many complex human diseases are largely determined by the availability and the quality of the biomarkers. A successful biomarker as an indicator to a specific biological or pathological process is usually selected from a large group of candidates by a strict verification and validation process. To be clinically useful, the validated biomarkers must be detectable and quantifiable by the selected testing techniques in their related tissues or body fluids. Due to its easy accessibility, protein biomarkers would ideally be identified in blood plasma or serum. However, most disease related protein biomarkers in blood exist at very low concentrations (<1ng/mL) and are “masked” by many none significant species at orders of magnitude higher concentrations. The extreme requirements of measurement sensitivity, dynamic range and specificity make the method development extremely challenging. The current clinical protein biomarker measurement primarily relies on antibody based immunoassays, such as ELISA. Although the technique is sensitive and highly specific, the development of high quality protein antibody is both expensive and time consuming. The limited capability of assay multiplexing also makes the measurement an extremely low throughput one rendering it impractical when hundreds to thousands potential biomarkers need to be quantitatively measured across multiple samples. Mass spectrometry (MS)-based assays have recently shown to be a viable alternative for high throughput and quantitative candidate protein biomarker verification. Among them, the triple quadrupole MS based assay is the most promising one. When it is coupled with liquid chromatography (LC) separation and electrospray ionization (ESI) source, a triple quadrupole mass spectrometer operating in a special selected reaction monitoring (SRM) mode, also known as multiple reaction monitoring (MRM), is capable of quantitatively measuring hundreds of candidate protein biomarkers from a relevant clinical sample in a single analysis. The specificity, reproducibility and sensitivity could be as good as ELISA. Furthermore, SRM MS can also quantify protein isoforms and post-translational modifications, for which traditional antibody-based immunoassays often don’t exist.

Environmental Molecular Sciences Laboratory↗

Robust Chemiresistive Behavior in Conductive Polymer/MOF Composites

Metal-organic frameworks (MOFs) are promising materials for gas sensing but are often limited to single-use detection. A hybridization strategy is demonstrated synergistically deploying conductive MOFs (cMOFs) and conductive polymers (cPs) as two complementary mixed ionic-electronic conductors in high-performing stand-alone chemiresistors. This work presents significant improvement in i) sensor recovery kinetics, ii) cycling stability, and iii) dynamic range at room temperature. The effect of hybridization across well-studied cMOFs is demonstrated based on 2,3,6,7,10,11-hexahydroxytriphenylene (HHTP) and 2,3,6,7,10,11-hexaiminotriphenylene (HITP) ligands with varied metal nodes (Co, Cu, Ni). A comprehensive mechanistic study is conducted to relate energy band alignments at the heterojunctions between the MOFs and the polymer with sensing thermodynamics and binding kinetics. The findings reveal that hole enrichment of the cMOF component upon hybridization leads to selective enhancement in desorption kinetics, enabling significantly improved sensor recovery at room temperature, and thus long-term response retention. This mechanism is further supported by density functional theory calculations on sorbate–analyte interactions. It is also found that alloying cPs and cMOFs enables facile thin film co-processing and device integration, potentially unlocking the use of these hybrid conductors in diverse electronic applications.

36 MATERIALS SCIENCE↗

Broadband THz Modulation via Solid–State Organic Electrochemical Devices

The sub-Terahertz and Terahertz bands play a critical role in next-generation wireless communication and sensing technologies, thanks to the large amount of available bandwidth in this spectral regime. While long-wavelength (microwave to mm-Wave) and short-wavelength (near-infrared to ultraviolet) devices are well-established and studied, the sub-THz to THz regime remains relatively underexplored and underutilized. Traditional approaches used in the aforementioned spectral regions are more difficult to replicate in the THz band, leading to the need for the development of novel devices and structures that can manipulate THz radiation effectively. Herein a novel organic, solid-state electrochemical device is presented, capable of achieving modulation depths of over 90% from ≈500 nm of a conducting polymer that switches conductivity over a large dynamic range upon application of an electronically controllable external bias. The stability of such devices under long-term, repeated voltage switching, as well as continuous biasing at a single voltage, is also explored. Switching stabilities and long-term bias stabilities are achieved over two days for both use cases. Additionally, both depletion mode (always “ON”) and accumulation mode (always “OFF”) operation are demonstrated. These results suggest applications of organic electrochemical THz modulators in large area and flexible implementations.

36 MATERIALS SCIENCE↗

Terahertz Detection Using Enhanced Two‐Step Absorption in Photoconductive Metasurfaces Gated at λ = 1.55 µm

Abstract Superior ultrafast photoconductive properties make low temperature grown (LT) GaAs one of the best materials for photoconductive terahertz (THz) detection. However, the large bandgap of LT‐GaAs limits its operation to gating at wavelengths shorter than 870 nm. Here, it is demonstrated for the first time that nanostructuring the LT‐GaAs into a highly absorbing metasurface enables THz photoconductive detection with a pulsed laser at λ = 1.55 µm. The very weak sub‐bandgap absorption mediated by midgap states in LT‐GaAs is strongly enhanced using the concept of perfect absorption via degenerate critical coupling. Integrated with a THz antenna, the LT‐GaAs metasurface enables high sensitivity THz detection with a high dynamic range of 60 dB and large bandwidth up to 4.5 THz. The LT‐GaAs metasurface has the potential to serve as a universal ultrafast switching element for THz applications, enabling low‐cost, turn‐key THz systems for a variety of real‐world applications.

Jung, Hyunseung↗

Polymer Size–Catalytic Activity Relationships in Solution by Fluorescence Correlation Spectroscopy

Measuring the catalytic activity of specific sizes of polymers with active catalysts in solution is typically challenging, due to limited instrument detection sensitivity and/or dynamic range. Here, a fluorescence correlation spectroscopy (FCS) method is developed to determine the catalytic activity of living polymers of a specific apparent size in solution. Deviation from a single-component FCS data fitting, as assessed by χ2, is also introduced and developed as a “speciation index”—a method to evaluate and track changes in the relative amount of distinct polymer sizes with reaction progress. These methods are enabled by incorporating a selectively reactive fluorescent monomer into growing polydicyclopentadiene or polynorbornene during ring-opening metathesis polymerization (ROMP). Compared to polynorbornene, data showed that catalysts in aggregates of polyDCPD retained higher activity for longer—outcomes not directly inferable from simple diffusional-access predictions. Here, the ability to assign catalytic activity to polymers of specific sizes, and then to determine how this activity evolves with reaction progress, support long-term goals in the development and measurement of nano-objects that possess size-dependent catalytic activity.

Active catalyst↗

Digital radiography exposure indices: A review

Digital radiography (DR) technologies have the advantage of a wide dynamic range compared to their film-screen predecessors, however, this poses a potential for increased patient exposure if left unchecked. Manufacturers have developed the exposure index (EI) to counter this, which provides radiographers with feedback on the exposure reaching the detector. As these EIs were manufacturer-specific, a wide variety of EIs existed. To offset this, the international standardised EI has been developed by the International Electrotechnical Commission (IEC) and the American Association of Physicists in Medicine (AAPM). The purpose of this article is to explore the current literature relating to EIs, beginning with the historical development of the EI, the development of the standardised EI and an exploration of common themes and studies as evidenced in the research literature. It is anticipated that this review will provide radiographers with a useful guide to understanding EIs, their application in clinical practice, limitations and suggestions for further research.

60 APPLIED LIFE SCIENCES↗

Room‐Temperature Mid‐Infrared Detection Using Metasurface‐Absorber‐Integrated Phononic Crystal Oscillator

Mid-infrared (MIR) detectors find extensive applications in chemical sensing, spectroscopy, communications, biomedical diagnosis, and space exploration. Alternative to semiconductor MIR photodiodes and bolometers, mechanical-resonator-based MIR detectors show advantages in higher sensitivity and lower noise at room temperature, especially toward longer wavelength infrared. Here, uncooled room-temperature MIR detectors based on lithium niobate surface acoustic wave phononic crystal (PnC) resonators integrated with wavelength-and-polarization-selective metasurface absorber arrays are demonstrated. The detection is based on the resonant frequency shift induced by the local temperature change due to MIR absorptions. The PnC resonator is configured in an oscillating mode, enabling active readout and low-frequency noise. The 1-GHz oscillator-based MIR detector shows a relative frequency deviation of 5.24 × 10 −10 Hz −1/2 at an integration time of 50 µs, leading to an incident noise equivalent power of 197 pW Hz −1/2 when input 6-µm MIR light is modulated at 1.8 kHz, and a large dynamic range of 10 7 in incident MIR power. The device architecture is compatible with the scalable manufacturing process and can be readily extended to a broader spectral range by tailoring the absorbing wavelengths of metasurface absorbers.

Xi, Zichen [Virginia Polytechnic Inst. and State U↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Reversed-Phase Chromatography with Multiple Fraction Concatenation Strategy for Proteome Profiling of Human MCF10A Cells

Two dimensional liquid chromatography (2D LC) is commonly used for shotgun proteomics to improve the analysis dynamic range. Reversed phase liquid chromatography (RPLC) has been routinely employed as the second dimensional separation prior to the mass spectrometric analysis. Construction of 2D separation with RP-RP arises a concern for the separation orthogonality. In this study, we applied a novel concatenation strategy to improve the orthogonality of 2D RP-RP formed by low pH (i.e., pH 3) and high pH (i.e., pH 10) RPLC. We confidently identified 3753 proteins (18570 unique peptides) and 5907 proteins (37633 unique peptides) from low pH RPLC-RP and high pH RPLC-RP, respectively, for a trypsin-digested human MCF10A cell sample. Compared with SCX-RP, the high pH-low pH RP-RP approach resulted in 1.8-fold and 1.6-fold in the number of peptide and protein identifications, respectively. In addition to the broader identifications, the High pH-low pH RP-RP approach has advantages including the improved protein sequence coverage, the simplified sample processing, and the reduced sample loss. These results demonstrated that the concatenation high pH-low pH RP-RP strategy is an attractive alternative to SCX for 2D LC shotgun proteomic analysis.

59 BASIC BIOLOGICAL SCIENCES↗