Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRONIC LEVEL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Modular Standards for Space Power Systems

This presentation presents an approach to provide commonality for future space power systems through a set of modular power standards. The approach presented breaks down the electrical power conversion and distribution system into the lowest level functions, which are represented by power electronics modules, and serve as the foundational building blocks of the system. A series of Modular Power Standards has been developed to define the functions and interfaces of the lowest level of the electrical power system, or for each type of power electronics module. The power electronics modules, when integrated with a common chassis and backplane, can then be built up into modular electronics assemblies, which have been demonstrated and characterized in a relevant ground test environment.

Gardner, Brent G.↗

F-15 digital electronic engine control system description

A digital electronic engine control (DEEC) was developed for use on the F100-PW-100 turbofan engine. This control system has full authority control, capable of moving all the controlled variables over their full ranges. The digital computational electronics and fault detection and accomodation logic maintains safe engine operation. A hydromechanical backup control (BUC) is an integral part of the fuel metering unit and provides gas generator control at a reduced performance level in the event of an electronics failure. The DEEC's features, hardware, and major logic diagrams are described.

Myers, L. P.↗

Deep levels and radiation effects in p-InP

A survey was conducted on past studies of hole traps in InP. An experiment was designed to evaluate hole traps in Zn-doped InP after fabrication, after electron irradiation and after annealing using deep level transient spectroscopy. Data similar to that of Yamaguchi was seen with observation of both radiation-induced hole and electron traps at E sub A=0.45 eV and 0.03 eV, respectively. Both traps are altered by annealing. It is also shown that trap parameters for surface-barrier devices are influenced by many factors such as bias voltage, which probes traps at different depths below the surface. These devices require great care in data evaluation.

Anderson, W. A.↗

Five myofibrillar lesion types in eccentrically challenged, unloaded rat adductor longus muscle--a test model

Sarcomere disruptions are observed in the adductor longus (AL) muscles following voluntary reloading of spaceflown and hindlimb suspension unloaded (HSU) rat, which resemble lesions in eccentrically challenged muscle. We devised and tested an eccentric contraction (ECCON) test system for the 14-day HSU rat AL. Six to 7 hours following ECCON, ALs were fixed to allow immunostaining and electron microscopy (EM). Toluidine blue-stained histology semithin sections were screened for lesion density (#/mm2). Serial semithin sections from the ECCON group were characterized for myosin immunointensity of lesions. Five myofibrillar lesion types were identified in histological semithin sections: focal contractions; wide A-bands; opaque areas; missing A-bands; and hyperstretched sarcomeres. Lesion density by type was greater for ECCON than NonECCON ALs (P< or =0.05; focal contractions and opaque regions). Lesion density (#-of-all-five-types/mm2) was significantly different (ECCON: 23.91+/-10.58 vs. NonECCON: 5.48+/-1.28, P< or =0.05; ECCON vs. SHAM: 0.00+/-0.00; P< or = 0.025). PostECCON optimal tension decreased (Poi-drop, 17.84+/-4.22%) and was correlated to lesion density (R2=0.596), but prestretch tension demonstrated the highest correlation with lesion density (R2=0.994). In lesions, the darkly staining A-band lost the normally organized thick filament alignment to differing degrees across the different lesion types. Ranking the five lesion types by a measure of lesion length deformation (hypercontracted to hyperstretched) at the light microscopy level, related to the severity of thick filament registry loss across the lesion types at the electron microscopic level. This ranking suggested that the five lesion types seen in semithin sections at the light level represented a lesion progression sequence and paralleled myosin immunostaining loss as the distorted A-band filaments spread across the hyperlengthening lesion types. Lesion ultrastructure indicated damage involved calcium homeostasis loss (focal contraction lesions) and "thick-filament-centering" failure of titin (wide A-band lesions) in the early stages of lesion development.

NASA Discipline Musculoskeletal↗

Atomic data for S IV and solar observations of the 3x/2/3p /2/P-3s3p/2/ /4/P multiplet

High resolution observations of intersystem lines of S IV near 1400 A are available from Skylab. These lines are potentially useful as density diagnostics for the solar atmosphere. Energy levels, transition probabilities and collision strengths have, therefore, been calculated for S IV, including the configurations 3x(2)3p, 3s3p(2), and 3s(2)3d. Line intensities and level populations have been calculated as a function of electron density. The calculated population of the 3s3p(2) (4)P(5/2) level is found to reach a pseudo-Boltzmann equilibrium at a density which is four times higher than is inferred from solar spectra and level population calculations of lighter ions such as O IV.

Bhatia, A. K.↗

Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: AMSU-A1 Antenna Drive Subsystem, PN 1331720-2, S/N 106

This is the Performance Verification Report, AMSU-A1 Antenna Drive Subsystem, P/N 1331720-2, S/N 106, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). The antenna drive subsystem of the METSAT AMSU-A1, S/N 106, P/N 1331720-2, completed acceptance testing per A-ES Test Procedure AE-26002/lD. The test included: Scan Motion and Jitter, Pulse Load Bus Peak Current and Rise Time, Resolver Reading and Position Error, Gain/ Phase Margin, and Operational Gain Margin. The drive motors and electronic circuitry were also tested at the component level. The drive motor test includes: Starting Torque Test, Motor Commutation Test, Resolver Operation/ No-Load Speed Test, and Random Vibration. The electronic circuitry was tested at the Circuit Card Assembly (CCA) level of production; each test exercised all circuit functions. The transistor assembly was tested during the W3 cable assembly (1356941-1) test.

Luu, D.↗

Arrival time distributions of electrons in air showers with primary energies above 10 (18)eV observed at 900m above sea level

Detection of air showers with primary energies above 10 to the 19th power eV with sufficient statistics is extremely important in an astrophysical aspect related to the Greisen cut off and the origin of such high energy cosmic rays. Recently, a method is proposed to observe such giant air showers by measuring the arrival time distributions of air-shower particles at large core distances with a mini array. Experiments to measure the arrival time distributions of muons were started in 1981 and those of electrons in early 1983 in the Akeno air-shower array (930 gcm cm squared atmospheric depth, 900m above sea level). During the time of observation, the detection area of the Akeno array was expanded from 1 sq km to sq km in 1982 and to 20 sq km in 1984. Now the arrival time distribution of electrons and muons can be measured for showers with primary energies above 1019eV at large core distances.

Kakimoto, F.↗

Quenching of the beam-plasma instability by 3-D spectra of large scale density fluctuations

A model is presented to explain the highly variable yet low level of Langmuir waves measured in situ by spacecraft when electron beams associated with Type III solar bursts are passing by; the low level of excited waves allows the propagation of such streams from the Sun to well past 1 AU without catastrophic energy losses. The model is based, first, on the existence of large scale density fluctuations that are able to efficiently diffuse small k beam unstable Langmuir waves in phase space, and, second, on the presence of a significantly isotropic nonthermal tail in the distribution function of the background electron population, which is capable of stabilizing larger k modes. The strength of the model lies in its ability to predict various levels of Langmuir waves depending on the parameters. This feature is consistent with the high variability actually observed in the measurements.

Muschietti, L.↗

Advancing Small Satellite Electronics Heritage for Microfluidic Biological Experiments

DLR's Eu:CROPIS (Euglena and Combined Regenerative Organic-Food Production in Space) mission, launching in 2017, will carry multiple biological payloads into a sun-synchronous orbit, including NASA Ames' PowerCell experiment. PowerCell will attempt to characterize the viability of synthetic biology at micro-g, Lunar, and Martian gravity levels. PowerCell experiment requirements demand an electronic system similar to previous microfluidic biology payloads, but with an expanded feature set. As such, the system was based on PharmaSat (Diaz-Aguado et al. 2009), a previous successful biology payload from NASA Ames, and improved upon. Newer, more miniaturized electronics allow for greater capability with a lower part count and smaller size. Two identical PowerCell enclosures will fly. Each enclosure contains two separate and identical experiments with a 48-segment optical density measurement system, grow light system, microfluidic system for nutrient delivery and waste flushing, plus thermal control and environmental sensing/housekeeping including temperature, pressure, humidity, and acceleration. Electronics consist of a single Master PCB that interfaces to the spacecraft bus and regulates power and communication, plus LED, Detector, and Valve Manifold PCBs for each experiment. To facilitate ease of reuse on future missions, experiment electronics were designed to be compatible with a standard 3U small sat form factor and power bus, or to interface with a Master power/comm PCB for use in a larger satellite as in the case of PowerCell's flight on Eu:CROPIS.

biology↗

Lower Level Repair Can Easily Fail Due to High Complexity

The International Space Station (ISS) uses Orbital Replacement Units (ORU’s) to repair failures on orbit. Using ORU’s reduces the crew time required to repair failures, but several copies of each ORU must be stored on ISS to ensure system availability. A typical ORU contains many components and has significant mass, but each ORU can repair only a single component failure. A full set of the ORU internal components could repair many different failures. Lower level assembly or component repair should reduce total spares mass. Successful electronics repair experiments were conducted on ISS. However, implementing component level repair would require a significant effort. The systems must be designed so they can be repaired during a mission, considering component layout and accessibility. The repair procedures must be developed and repair facilities, tools, and diagnostic and test instruments provided. Tracing a fault to a component is much more difficult than isolating it to an ORU. Replacing a component is much more difficult than replacing an ORU. Some problems with lower level repair are discussed. The mass savings of lower level repair will not save as much launch cost as before since launch cost has recently been reduced by an order of magnitude. Most system failures are not component failures that can be fixed by replacing a component but are due to system level problems. Repair and maintenance should be planned as part of an overall maintainability design. The risk that a lower level repair will fail is considerably greater than when using ORUs. With modern high reliability packaged systems, failure diagnosis and repair has become a lost art. However, diagnosis and repair data from the 1960’s show that increasing complexity often causes much longer diagnosis and repair times and may prevent successful repair. Increasing complexity by using lower level repair directly increases system cost, failure rate, crew time for repair, and the risk of an unrepairable system failure.

Harry W Jones↗

Development and flight tests of a gyro-less wing leveler and directional autopilot

A gyro-less wing leveler and directional autopilot were developed and flight tested in a single-engine light airplane. The primary purpose of the project was to develop a simple, reliable, low-cost stability augmentation and autopilot system for light aircraft. The wing leveler used a fluidic inertial rate sensor, electronic signal processing circuitry, and vacuum operated servos. A strap-down magnetic heading reference of simple design provided the wing leveler with directional autopilot capability. Flight tests indicated that the performance of the gyro-less wing leveler was equal to that of a commercial wing leveler using a gyroscopic rate sensor. Drift-free, long-term, heading-hold capability of the magnetic heading reference was demonstrated.

Garner, H. D.↗

Studies of electron collisions with polyatomic molecules using distributed-memory parallel computers

Elastic electron scattering cross sections from 5-30 eV are reported for the molecules C2H4, C2H6, C3H8, Si2H6, and GeH4, obtained using an implementation of the Schwinger multichannel method for distributed-memory parallel computer architectures. These results, obtained within the static-exchange approximation, are in generally good agreement with the available experimental data. These calculations demonstrate the potential of highly parallel computation in the study of collisions between low-energy electrons and polyatomic gases. The computational methodology discussed is also directly applicable to the calculation of elastic cross sections at higher levels of approximation (target polarization) and of electronic excitation cross sections.

Winstead, C.↗

Electron density distribution in the magnetosphere

Eight months of differential potential measurements from the POLAR satellite were used to study the electron density distribution in the magnetosphere and its dependence on the level of geomagnetic activity identified by the Kp index. The differential potential measurement is directly proportional to the electron density, and this technique can be used for detecting fast electron density variation in low-density plasmas with a good accuracy. The inner magnetospheric regions are particularly investigated in this study. The cusp is found to be denser during low Km, and it moves equator-ward with increasing Km. The plasmapause is quite asymmetric, as expected. In particular, on the nightside, the plasmapause is compressed closer to the earth with increasing Kp. While the density gradients at the dayside plasmapause are usually not very steep, they can be quite large at other time sectors. A particularly pronounced sharpening of the plasmapause occurs at the dusk sector with increasing Kp. The density in the region between the dayside plasmapause and magnetopause is relatively high during all Kp levels; the average densities are several electrons per cubic meter. During disturbed periods, the density in the near-earth plasma sheet near midnight increases and becomes higher than the densities towards the flanks of the plasma sheet.

Laakso, H.↗

Radiation damage and defect behavior in proton irradiated lithium-counterdoped n+p silicon solar cells

Two lithium-counterdoped n+p silicon solar cells with different lithium concentrations were irradiated by 10-MeV protons. Cell performance was measured as a function of fluence, and it was found that the cell with the highest concentration of lithium had the highest radiation resistance. Deep level transient spectroscopy which showed two deep level defects that were lithium related. Relating the defect energy levels obtained from this study with those from earlier work using 1-MeV electron irradiation shows no correlation of the defect energy levels. There is one marked similarity: the absence of the boron-interstitial-oxygen-interstitial defect. This consistency strengthens the belief that lithium interacts with oxygen to prevent the formation of the boron interstitial-oxygen interstitial defect. The results indicate that, in general, addition of lithium in small amounts to the p-base of a boron doped silicon solar cell such that the base remains p-type, tends to increase the radiation resistance of the cell.

Stupica, John↗

Modern Material Analysis Instruments Add a New Dimension to Materials Characterization and Failure Analysis

Modern analytical tools can yield invaluable results during materials characterization and failure analysis. Scanning electron microscopes (SEMs) provide significant analytical capabilities, including angstrom-level resolution. These systems can be equipped with a silicon drift detector (SDD) for very fast yet precise analytical mapping of phases, as well as electron back-scattered diffraction (EBSD) units to map grain orientations, chambers that admit large samples, variable pressure for wet samples, and quantitative analysis software to examine phases. Advanced solid-state electronics have also improved surface and bulk analysis instruments: Secondary ion mass spectroscopy (SIMS) can quantitatively determine and map light elements such as hydrogen, lithium, and boron - with their isotopes. Its high sensitivity detects impurities at parts per billion (ppb) levels. X-ray photo-electron spectroscopy (XPS) can determine oxidation states of elements, as well as identifying polymers and measuring film thicknesses on coated composites. This technique is also known as electron spectroscopy for chemical analysis (ESCA). Scanning Auger electron spectroscopy (SAM) combines surface sensitivity, spatial lateral resolution (10 nm), and depth profiling capabilities to describe elemental compositions of near and below surface regions down to the chemical state of an atom.

Panda, Binayak↗

Fast response cryogen level sensor

Liquid level in cryogenic tank or pipe, or amount of gas trapped in pipeline flow, is monitored electronically by cylindrical capacitive sensor. Changes in liquid level between concentric tubes of capacitor change its impedance, varying current in drive circuit. Since it is oriented parallel to direction of liquid flow, sensor presents little resistance to moving fluid.

Fitzpatrick, J. B.↗

Radar Sounding of Mars: A Focus on MARSIS

Radar has the unique capability of looking under the dry and cold surfaces of Mars. The depth of penetration of radio waves depends on a number of surface and subsurface parameters such as surface topography, subsurface geological structure, and surface and subsurface electromagnetic properties. Among these parameters, the surface topography is known best largely due to valuable data provided by Mars Global Surveyor's MOLA (Mars Orbiter Laser Altimeter) instrument. However, little information is available on the electromagnetic properties and subsurface characteristics of Mars. In addition to dispersion, the ionosphere will also attenuate the radio wave. The level of attenuation depends on the ionosphere's electron density and its profile shape and the electron-neutral collision frequency. Fortunately, information from past missions can provide some information on the expected level of attenuation. A figure shows expected total radio wave attenuation under three different ionospheric conditions. Additional information is contained in the original extended abstract.

Safaeinili, A.↗

Mineralization of collagen may occur on fibril surfaces: evidence from conventional and high-voltage electron microscopy and three-dimensional imaging

The interaction between collagen and mineral crystals in the normally calcifying leg tendons from the domestic turkey, Meleagris gallopavo, has been investigated at an ultrastructural level with conventional and high-voltage electron microscopy, computed tomography, and three-dimensional image reconstruction methods. Specimens treated by either aqueous or anhydrous techniques and resin-embedded were appropriately sectioned and regions of early tendon mineralization were photographed. On the basis of individual photomicrographs, stereoscopic pairs of images, and tomographic three-dimensional image reconstructions, platelet-shaped crystals may be demonstrated for the first time in association with the surface of collagen fibrils. Mineral is also observed in closely parallel arrays within collagen hole and overlap zones. The mineral deposition at these spatially distinct locations in the tendon provides insight into possible means by which calcification is mediated by collagen as a fundamental event in skeletal and dental formation among vertebrates.

NASA Discipline Musculoskeletal↗