Search NASA⌕ Search

SEARCH · Search NASA

Results for “Earth movements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

475 records · Page 27

Integration of the Shuttle RMS/CBM Positioning Virtual Environment Simulation

Constructing the International Space Station, or other structures, in space presents a number of problems. In particular, payload restrictions for the Space Shuttle and other launch mechanisms prohibit assembly of large space-based structures on Earth. Instead, a number of smaller modules must be boosted into orbit separately and then assembled to form the final structure. The assembly process is difficult, as docking interfaces such as Common Berthing Mechanisms (CBMS) must be precisely positioned relative to each other to be within the "capture envelope" (approximately +/- 1 inch and +/- 0.3 degrees from the nominal position) and attach properly. In the case of the Space Station, the docking mechanisms are to be positioned robotically by an astronaut using the 55-foot-long Remote Manipulator System (RMS) robot arm. Unfortunately, direct visual or video observation of the placement process is difficult or impossible in many scenarios. One method that has been tested for aligning the CBMs uses a boresighted camera mounted on one CBM to view a standard target on the opposing CBM. While this method might be sufficient to achieve proper positioning with considerable effort, it does not provide a high level of confidence that the mechanisms have been placed within capture range of each other. It also does nothing to address the risk of inadvertent contact between the CBMS, which could result in RMS control software errors. In general, constraining the operator to a single viewpoint with few, if any, depth cues makes the task much more difficult than it would be if the target could be viewed in three-dimensional space from various viewpoints. The actual work area could be viewed by an astronaut during EVA; however, it would be extremely impractical to have an astronaut control the RMS while spacewalking. On the other hand, a view of the RMS and CBMs to be positioned in a virtual environment aboard the Space Shuttle orbiter or Space Station could provide similar benefits more safely and conveniently with little additional cost. In order to render and view the RMS and CBMs in a virtual world, the position and orientation of the end effector in three-dimensional space must be known with a high degree of accuracy. A precision video alignment sensor has been developed which can determine the position and orientation of the controlled element relative to the target CBM within approximately one-sixteenth inch and 0.07 angular degrees. Such a sensor could replace or augment the boresighted camera mentioned above. The computer system used to render the virtual world and the position tracking systems which might be used to monitor the user's movements (in order to adjust the viewpoint in virtual space) are small enough to carry to orbit. Thus, such a system would be feasible for use in constructing structures in space.

Dumas, Joseph D.↗

A Miniaturized Video System for Monitoring Drosophila Behavior

Long-term spaceflight may induce a variety of harmful effects in astronauts, resulting in altered motor and cognitive behavior. The stresses experienced by humans in space - most significantly weightlessness (microgravity) and cosmic radiation - are difficult to accurately simulate on Earth. In fact, prolonged and concomitant exposure to microgravity and cosmic radiation can only be studied in space. Behavioral studies in space have focused on model organisms, including Drosophila melanogaster. Drosophila is often used due to its short life span and generational cycle, small size, and ease of maintenance. Additionally, the well-characterized genetics of Drosophila behavior on Earth can be applied to the analysis of results from spaceflights, provided that the behavior in space is accurately recorded. In 2001, the BioExplorer project introduced a low-cost option for researchers: the small satellite. While this approach enabled multiple inexpensive launches of biological experiments, it also imposed stringent restrictions on the monitoring systems in terms of size, mass, data bandwidth, and power consumption. Suggested parameters for size are on the order of 100 mm3 and 1 kg mass for the entire payload. For Drosophila behavioral studies, these engineering requirements are not met by commercially available systems. One system that does meet many requirements for behavioral studies in space is the actimeter. Actimeters use infrared light gates to track the number of times a fly crosses a boundary within a small container (3x3x40 mm). Unfortunately, the apparatus needed to monitor several flies at once would be larger than the capacity of the small satellite. A system is presented, which expands on the actimeter approach to achieve a highly compact, low-power, ultra-low bandwidth solution for simultaneous monitoring of the behavior of multiple flies in space. This also provides a simple, inexpensive alternative to the current systems for monitoring Drosophila populations in terrestrial experiments, and could be especially useful in field experiments in remote locations. Two practical limitations of the system should be noted: first, only walking flies can be observed - not flying - and second, although it enables population studies, tracking individual flies within the population is not currently possible. The system used video recording and an analog circuit to extract the average light changes as a function of time. Flies were held in a 5-cm diameter Petri dish and illuminated from below by a uniform light source. A miniature, monochrome CMOS (complementary metal-oxide semiconductor) video camera imaged the flies. This camera had automatic gain control, and this did not affect system performance. The camera was positioned 5-7 cm above the Petri dish such that the imaging area was 2.25 sq cm. With this basic setup, still images and continuous video of 15 flies at one time were obtained. To reduce the required data bandwidth by several orders of magnitude, a band-pass filter (0.3-10 Hz) circuit compressed the video signal and extracted changes in image luminance over time. The raw activity signal output of this circuit was recorded on a computer and digitally processed to extract the fly movement "events" from the waveform. These events corresponded to flies entering and leaving the image and were used for extracting activity parameters such as inter-event duration. The efficacy of the system in quantifying locomotor activity was evaluated by varying environmental temperature, then measuring the activity level of the flies.

Bhattacharya, Sharmila↗

TOWARD A METHOD FOR SCALING HUMAN BODY MODELS IN AN IMU-BASED WORKFLOW

BACKGROUND Scaled biomechanical models can more accurately inform crew health decisions when tailored to the wide range of astronaut sizes. One component to improve scaling of existing models to better represent each unique astronaut’s size is the individual length scaling of limbs. Traditionally, these lengths are determined by motion capture or manual measurement. A new method is herein proposed for length scaling which can be done by measuring linear and angular accelerations at a desired point during isolated motion around a point of rotation, then calculating the distance between the desired point and point of rotation. When an Inertial Measurement Unit (IMU) device is placed at the distal point of a limb, the isolated motion is about that limb’s proximal joint. For example, to measure forearm length, an IMU is placed at the wrist, the point of rotation is at the elbow, and the isolated motion is forearm flexion and extension. These calculated lengths are then used to scale models to each unique astronaut’s size, thereby improving the applicability of the model. This method of scaling limb segments can be used for any limb that has an easily defined proximal joint for the limb to rotate around including hands, arms, legs, feet. Utilizing IMUs for data collection also provides the synergistic ability to record data without a dedicated space in a room with many cameras, therefore reducing the data collection footprint, or record data where optical motion capture is not possible, such as inside a spacesuit. METHODS AND RESULTS To test this method, upper body data collection was performed with 5 Xsens DOT IMUs on a single subject. IMUs consist of an accelerometer, a gyroscope, and a magnetometer which collect linear acceleration, angular velocity, and magnetic fluctuations, respectively. Before any ground-based laboratory collection, the magnetic fluctuations are used to correct the heading of the IMU in space relative to the Earth’s magnetic field. The direct measurement of angular velocity is integrated to calculate angular acceleration. Then the linear acceleration ( a ) and angular acceleration (α) are solved using r = at/α to calculate the radius, which in this case is the distance between the IMU and the point of rotation (i.e., segment length). The IMU must be placed at the most distal point of the limb being measured (i.e., ankle if measuring lower leg length) and the test plan must consist of an isolated motion about that limb’s proximal joint (i.e., knee flexion and extension if measuring lower leg length). The distances (radii) calculated at every time interval were filtered (bandpass filter keeping 5th-90th percentile data) to eliminate outliers and spurious data that occur when the isolated motion was stopped or nearly stopped. The remaining distances were averaged, resulting in the calculated limb length. Scaling factors were then computed by dividing the calculated limb length by the unscaled model’s length. These scale factors are plugged into the Scale Tool in OpenSim [1,2] to apply the scaling to the OpenSim Full Body Rajagopal Model [3,4]. Manual measurements of limb lengths were taken before data collection started and used for comparing against the calculated lengths. The Anthropometric Survey of US Army Personnel (ANSUR II) [5] was also used as a third source of reference for limb length measurements. The following measurements were retrieved from the subject before data collection: 34.5 cm from L1 to C7 (thorax), 25.7 cm from C7 Joint Center (JC) to head vertex (neck and head), 36.3 cm from shoulder JC to elbow JC (humerus), 29.5 cm from elbow JC to wrist JC (forearm), and 16.2 cm from clavicle to acromion (clavicle). Of those five, forearm and humerus lengths were calculated using this proposed method to obtain preliminary results. The forearm length after filtering and averaging was calculated to be 37.6 cm. This is a 28% overestimation from the measured forearm length (29.5 cm). The humerus length after filtering and averaging was calculated to be 47.8 cm. This is a 31% difference from the measured subject length (36.3 cm). Sources of error include imperfect isolated motion (method currently expects that motion should be perfectly circular in a 2D plane, include no rotation of the IMU, and be relatively smooth; a more secure IMU attachment method will help), unrefined filter techniques (removed highest and lowest values with 20% high and low pass filters and no smoothing filters), arbitrary removal of stopped or near stopped data (kept data for only a short range before and after the angular velocity peaking), and a more representative method for removing gravitational acceleration is needed (current method is to zero all accelerations against a baseline taken just before the isolated motion which does not account for the gravitational acceleration changed due to IMU rotation during movement). Addressing these error sources will improve the accuracy of the limb length calculation. Next steps include creating a method for whole-body scaling estimation using individual limb scale factors. Continued pursuit of these techniques is expected to enable acquiring anthropometric information using only IMUs in real-time.

E. K. Marecki↗

Exploiting the Temperature Dependence of Magnetic Susceptibility to Control Convection in Fundamental Studies of Solidification Phenomena

It is well known that convection is a dominant mass transport mechanism when materials are solidified on Earth's surface. This convection is caused by gradients in density (and therefore gravitational force) that are brought about by gradients in temperature, composition or both. Diffusion of solute is therefore dwarfed by convection and the study of fundamental parameters, such as dendrite tip shape and growth velocity in the absence of convection is nearly impossible. Significant experimental work has therefore been carried out in orbiting laboratories with the intent of minimizing convection by minimizing gravity. One of the best known experiments of this kind is the Isothermal Dendritic Growth Experiment (IDGE), supported by NASA. Naturally such experiments are costly and one objective of the present investigation is to develop an experimental method whereby convection can be- halted, in solidification and other experiments, on the surface. A second objective is to use the method to minimize convection resulting from the residual accelerations suffered by experiments in microgravity. The method to be used to minimize convection relies on the dependence of the magnetic susceptibility of a fluid on temperature or composition (whichever is driving convection). All materials experience a force when placed in a magnetic field gradient. The direction and magnitude of that force depend on the magnetic susceptibility of the material. Consequently the force will vary if the susceptibility varies with temperature or composition. With a magnetic field gradient in the right direction (typically upward) and of the right magnitude, this variation in the magnetic force can be made to exactly cancel the variation in the gravitational force. Expressed another way, normal buoyancy is exactly countered by a "magnetic buoyancy". To demonstrate the principle, a solution of MnC12 in water has been used. First the variation of the susceptibility of this paramagnetic solution with temperature and concentration was measured. Then a "cell", containing this solution and 50mm long by 15mm high by 155mm wide, was placed in a superconducting magnet at Marshall Space Flight Center. The magnetic field was measured at various positions within the bore of the magnet using a Hall effect probe. In this way, a position was found where the magnetic field gradient was predominantly upward; the magnitude of the gradient could then be adjusted by adjusting the current of the magnet. The ends of the cell consisted of machined copper blocks maintained at controlled temperatures by circulating water from constant temperature baths. The walls of the cell were of rectangular section glass tubing so that the cell contents could be seen. Velocities arising from thermal gradients within the cell were measured by particle image velocimetry (PIV). Particles used for this purpose were silver-coated hollow glass spheres of micrometers diameter and nearly the same density as the solution. A central vertical plane of the cell was illuminated by a laser beam passing through a cylindrical lens. Digital images of the particles were captured on a CCD camera and fed to a computer so that frame-to-frame movements of particles traveling with the fluid were captured. These images were employed to compute velocity maps using commercial PIV software. In a typical experiment the cold end of the cell was maintained at 10C and the warm end at 30 C. With no current in the magnet, i.e.- with natural -convection allowed to occur, the fluid was observed to circulate with an average speed of approximately 0.3 millimeters per second. It was visually apparent that this circulation was diminished as the current was increased. At currents of approximately 20A the flow was halted, to within the precision of the PIV measurements. At yet higher currents the convection was reversed with the hotter solution sinking and the cooler solution rising. At 40A this reversed convection had speeds averaging 0.43 millimeters per second. The measurements of susceptibility and density allow an estimate of the field gradient necessary to halt convection in the experiment. That estimate was 7.8T (squared) per meter and the convection was observed to halt in the magnet at a current giving 7.21T (squared) per meter from the magnetic field measurements. Calculations of the flow have been carried out using the computational fluid dynamics software FLUENT and show good agreement with the measurements.

Seybert, C. D.↗

Autonomous Ocean World Exploration: Advancement of a Virtual Testbed

The search for life (extinct or extant) and potentially habitable bodies in our solar system and beyond is one of the 12 priority science questions outlined in the National Acadamies’ 2022 decadal survey [5]. Extraterrestrial destinations containing liquid water present an opportunity to search for life as we know it, and in recent years an increasing number of such locations have been discovered within our solar system. Several Jovian moons—Europa, Ganymede, and Callisto [10]—and the Saturnian moons Enceladus [8] and Titan [9] are known or suspected to harbor massive subsurface oceans. Of these "ocean worlds", Europa is the focus of at least one planned NASA orbiter mission, Europa Clipper [4], and an early lander mission concept, the Europa Lander [2, 3]. Whereas most robotic missions to the Moon and Mars (e.g. orbiters, rovers, landers) to date have had ground controllers on Earth tightly involved in mission operations, missions to more distant worlds will require a high degree of onboard autonomy due to long communication lags and blackouts, harsh environments (radiation, cold), and more limited battery and hardware life. The past decade has seen great advances in both AI technologies and computing scalability and performance that offer promising solutions for spacecraft autonomy and motivate the software system and research programs described in this paper. The Ocean Worlds Autonomy Testbed for Exploration, Research, and Simulation (OceanWATERS) [1], which has been in development at the NASA Ames Research Center since 2018, is a virtual environment for testing lander autonomy solutions. It is built on the Robot Operating System (ROS), runs on consumer-grade Linux workstations, and was released as open source in 2020. OceanWATERS provides a physical and visual simulation of a prototypical lander in a Europa-like environment (Figure 1). The lander was modeled after requirements and specifications made in JPL’s Europa Lander Study of 2016 [3]. Simulated lander systems include stereo cameras and spotlights mounted on an antenna mast that pans and tilts, a 6 degrees of freedom (DoF) robotic arm with a force-torque sensor and two interchangeable end effectors, and a battery pack power system. The environment consists of multiple terrain models including a highly detailed model sourced from the FROST dataset [11], simulation of surrounding planetary bodies based on an ephemeris model, and lighting from the sun with associated surface illumination, reflectance, and shadows. Operations supported by OceanWATERS include panoramic and directed imaging of the environment and lander workspace, Cartesian and joint-level arm commanding, grinding of the terrain surface (e.g. digging a trench), and scooping of ground material (Figure 2) which can be discarded or collected as science samples in a receptacle that can be emptied (science operations themselves are not simulated). These operations are realized as ROS Actions and are complimented by a wide selection of telemetry that is continually produced by each lander subsystem. The power system model is driven by the open-source Generic Software Architecture for Prognostics (GSAP) [11] that predicts the battery’s remaining useful life and other characteristics. As a testbed for high-level autonomy, OceanWATERS provides an execution framework based on PLEXIL [12], an open-source plan specification language and execution engine developed largely at Ames. NASA's initial development of OceanWATERS, as well the Ocean Worlds Lander Autonomy Testbed (OWLAT) [6], a complimentary physical testbed developed at JPL, was the first step in a plan for realizing candidate onboard autonomy solutions for such planetary landers. In 2020 NASA solicited applications for its Autonomous Robotics Research for Ocean Worlds (ARROW) program, and in 2021 the similar Concepts for Ocean worlds Life Detection Technology (COLDTech) program. Collectively six research teams, based in universities and companies across the United States, were awarded grants to develop and demonstrate autonomy solutions on OceanWATERS and OWLAT. These 1–2-year projects have now finished or are nearing completion, and a wide variety of autonomy challenges in ocean world surface missions were addressed. Prototyped and demonstrated solutions have included autonomous discovery, response and adaptation to system faults and unexpected environmental events, world model synthesis through perception, plan synthesis using learned models, methods to optimize sample target selection and prioritize science data transmission, extension of PLEXIL for stochastic decision-making, and an integration of a model of JPL’s mission-ready COLDArm [7]. Technologies used in these projects include many forms of machine learning, causal reasoning, automated planning, Markov decision processes, formal methods, and other advanced techniques. A more detailed summary of the ARROW and COLDTech projects is given herein. OceanWATERS has had significant enhancements since its open-source release in 2020. Many of its new features were driven or shaped by feedback from the ARROW and COLDTech teams and requirements of their projects. In support of enabling autonomous adaptation to spacecraft faults (a specific capability solicited by both programs), a fault injection and detection framework was developed that supports a wide and growing range of fault types such as locked joints, image loss, and battery failures. The power system model was completed and integrated into the simulator, starting as a single-cell battery model and later upgraded to a multi-cell model with associated faults such as cell disconnection. Arm/terrain interaction was improved by adding a force-torque sensor and associated faults, and an analytic dig force model based on the Balovnev bucket force equations. Environment fidelity was increased by modeling terrain deformation resulting from digging and scooping; visual improvements were made in textures, lighting, and shadows. To facilitate interoperation with OWLAT, a unified command and telemetry interface between the testbeds was developed at the ROS level, along with a PLEXIL interface. The number of lander operations was greatly expanded (e.g. with Cartesian-based arm and antenna movement), and a framework was designed for users to build their own lander actions. A GUI for PLEXIL plan selection was created (Figure 3), and an expansive set of plans were added, such as those that illustrate patterns for fault handling. This paper provides a self-contained high-level description of OceanWATERS, focusing on more detailed coverage of the aforementioned enhancements. It provides a high-level summary of the projects undertaken by participants in the ARROW and COLDTech programs and how these efforts have helped shape OceanWATERS. Finally, potential future work and directions for the testbed are listed, as likely informed by the recent planetary science decadal survey [5].

K Michael Dalal↗

EVA Swab Kit: Tools and Techniques for Collecting Aseptic Samples from Crewed Space Missions

Introduction: When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed spacecraft meet planetary protection requirements—and to protect our science from human contamination—we'll need to assess and verify whether micro-organisms may be leaking/venting from our spacesuits. This requires collecting samples under Extravehicular Activity (EVA) conditions. Detailed, systematic research on forward contamination from robotic spacecraft has been steadily progressing since the Viking missions, but systematic studies of contamination from space suits has not been conducted in many years. The modern EMU (Extravehicular Mobility Unit) suit used by NASA is designed to leak at rates as high as 100 cc/min. Before humans land on Mars there is a critical need to understand the types and quantities of microbes that could be introduced via space suits. The Human Forward Contamination Assessment team at NASA’s Johnson Space Center (JSC) has developed a prototype EVA swab tool [1,2,3,4] designed for use in space to sample cleaned and uncleaned space suits to determine the present day microbial load and eventually the rate of leakage. The ability to assess microbial leakage early in advanced space suit and life support system design cycles will help avoid costly hardware redesign later. Test Objectives: The primary objective of EMU testing was to characterize the type of micro-organisms typically found on or near selected suit pressure joints under suit differential pressure conditions. Most human-borne microbes can fit through a 0.5 to 1.0 µm gap. Knowing which joints are more likely to leak will inform hardware design decisions. Knowing which types of micro-organisms may leak from EVA suits provides a basis for subsequent studies to characterize the viability of those organisms under destination conditions, as well as how far they might spread through natural or human-influenced processes. That data, in turn, will inform exploration mission operations and hardware design. The secondary objective of testing was to evaluate the interface between a fully suited test subject and the EVA swab tool at vacuum. Bulky EVA suits can restrict movement and limit visibility through the helmet visor. Fully suited testing is important for identifying tool design issues prior to flight. At exploration destinations, such as Mars, suited crew may be required to periodically sample their suits as part of an environmental monitoring protocol. Suit Microbial Sampling Results: This report details results of microbial swabs collected from current flight suit configurations worn by crew members assigned to upcoming ISS expedition missions as well as swabs collected from prototype suits intended for use on the Orion spacecraft. These tests were intended to characterize the types of contaminants found on flight suits under current, typical handling conditions. No attempt was made to change suit handling procedures, provide additional sterilization, or to limit typical potential contaminant sources. Using culture based techniques, we cultivated 235 CFU (colony forming units) comprised of 26 bacterial species and one fungal species on the outside of the suits. The fungal species and 14 of the bacterial species were unique to the suit surfaces and were not detected in any of the background samples collected within the chambers. We sequenced 755,434 ribosomal fragments on all of the suit surfaces from swab samples. 557,016 of these sequences represent DNA that survived at least 4 hours at vacuum. These sequences formed 2,464 OTU's (Operational Taxonomic Units, 97% similarity) showing low diversity in the samples. The most abundant sequences that survived vacuum belong to the genera Staphyloccocus, Ralstona, Bacillus and Rhodobacter all of which are common to the human microbiome. [5] See Danko et al., (2021) for more complete details of these first analyses. Further analysis of EVA suit materials with respect to the efficacy of various cleaning protocols and engineered containment solutions is planned to inform suit design for NASA’s Artemis Moon to Mars program crew testing. Swab Tool Function Results: The kit was demonstrated for fit and function in suited subject vacuum tests to determine how well the tool worked as an aseptic microbial sampling device as well as to identify any design elements that could be upgraded for EVA task specific improvement. It was found that sample acquisition efficacy could be enhanced by redesign of the sample canister to end-effector interface. Several modifications of the sample caddy assemblies to optimize EVA safety and functionality were also identified. Consequently, fabrication of the redesigned sample canister to end-effector assembly interfaces and and the sample caddy assemblies are required. Fabrication of sixteen flight sample canister assemblies (8 per each of two EVA Swab Kits) and two sample caddy assemblies are in process to be followed by hardware testing and certification to produce two flight-certified EVA Swab Kits for transport to ISS no earlier than summer of 2022. Sampling Strategy: The International Space Station is an ideal testbed for systematic studies of contamination from crewed vehicles since it has been continuously occupied for 20 years and exposed to non-terrestrial conditions. We will sample the exterior of the ISS during EVA using a purpose-built swab tool capable of maintaining sterility while undergoing temperature changes from -151 to +121°C under hard vacuum. Prior to each EVA, the project team will work with ISS mission managers to identify precise sampling locations, which will vary by EVA based on the translation paths and worksites scheduled for that particular EVA. Ideally, translation path handrails and areas near ECLSS (Environmental Control and Life Support System) external vent openings on a spacecraft would be assessed. There are currently more than a dozen ECLSS external vents on the ISS. Some are connected to systems that vent waste products, while others are intended to equalize cabin pressure. As EVA opportunity allows, microbial samples from any of these external vents would provide a valuable data point, though some will be more useful than others. Four criteria have been identified to help prioritize sampling sites near vents: • EVA Accessibility: To minimize cost, it is desired to piggy-back onto a planned EVA. Therefore, the sampling location must be readily accessible by an EVA crew • Type of Vented Products: Vent products that have been in direct contact with crew, such as cabin air, are more likely to contain microorganisms than vent products associated with isolated systems, such as experiment module combustion products. • Mass of Vented Products: Higher-flow vents are more likely to contain detectible levels of microbial contaminants than lower-flow vents. • Local Environment: Sample locations with relatively benign local conditions, such as warm surfaces shielded from direct ultraviolet (UV) radiation exposure, may be more likely to support microbial growth than locations with harsher local environmental conditions. Because EVA accessibility is the most important criteria, the proposal team worked with an astronaut and flight controllers using the Dynamic Onboard Ubiquitous Graphics (DOUG) tool. The DOUG virtual environment allows an operator to “fly” around the current ISS vehicle configuration to assess EVA translation paths, attach points, and keep-out zones. While analysis on station or rapid return to Earth would be preferable, samples collected from the exterior of the ISS have already been exposed to temperature variations between -157 and +121 °C as well as hard vacuum. Therefore, they should be fairly stable and robust. We hypothesize that samples collected from the ISS exterior could be stored for up to 6 months at -80°C without degradation. Sample canisters will be returned to Earth while frozen at -80°C for analysis, and sterilized canisters can be re-flown back to ISS to support additional sampling opportunities Relevance to NASA Exploration Objectives: These data will allow us to identify new or improved methods, technologies, and procedures for spacecraft sterilization and leakage mitigation to minimize the amount of contamination introduced to the environment by human explorers. This work is funded by NASA research grant: NNH18ZDA001N-PPR References: [1] Bell, M.S. et al. (2015) LPS XLVI, Abst. #1832 [2] Rucker et al. (2018) 42nd COSPAR (PPP.3) [3] Bell, M.S. et al. (2019) Mars Extant Life Conference, Abst. #5096.[4] Bell, M.S. et al., (2020) 43rd COSPAR (BO.2).[5] Danko D, et.al.,(2021)Front.Microbiol.12:608478.

Mary Suzanne Bell↗

Miniature Exercise Device-2 (MED-2): Preliminary ISS Evaluation Results for a Compact Motorized Resistive and Aerobic Rowing Exercise Device

Future human missions beyond Low Earth Orbit (LEO) will require onboard equipment to provide exercise capabilities for the crew to counter the adverse physiological effects of long-duration microgravity. To accomplish this within the physical constraints of a space vehicle or transit module, a single miniature device that provides both resistive and aerobic exercise modalities is required. To meet this need, Johnson Space Center’s (JSC) Software, Robotics, and Simulation Division (ER) developed the Miniature Exercise Device-2 (MED-2). MED-2 integrates a torque-controlled servomotor and a series-elastic actuator to provide highly-controllable load profiles and a large magnitude output performance in a very small package. This innovative technology is derived from years of JSC/ER design, development and operational experience with cutting-edge robotics, motor controllers, software and actuator/sensor miniaturization, including Robonaut 2 and MED-1. MED-2 was presented at the 2016 ISS R&D Conference. This is an update now that the last of six crewmembers will have completed planned MED-2 sessions on the International Space Station (ISS) in May 2018.Current state-of-the-art ISS exercise equipment consists of two treadmills, a resistive exercise device and two cycle ergometers with a total mass of several thousand pounds and a total volume of several cubic yards. This equipment has proven vital to mitigate the musculoskeletal and cardiovascular degradation effects of microgravity. However, due to the large operational volume and mass of these ISS devices, tailoring them for smaller vehicles, such as Orion, is not possible. In addition, each of the current ISS devices targets a single specific modality. Compared to the existing spaceflight (and even terrestrial) exercise equipment, MED-2 is a new archetype altogether. The combined features of compact size, multi-modality and high-performance is attributable to its innovative series elastic actuator and motor controller. Following its arrival on ISS in 2016, MED-2 was evaluated in two parts. The first and shorter evaluation was an engineering functional checkout of the hardware. As this was a novel exercise device previously never used on ISS, the initial checkout assessed the operation of the hardware and ensured the motion and dynamic range of the crew did not present any collision or other hazards. The second portion of the study collected the heart rates, kinematics and utilized operational volumes of six astronauts to determine the quality of both the resistive and aerobic exercise modalities as delivered by MED-2. Investigators from JSC Biomedical Research and Environmental Science Division (SK) and Glenn Research Center are currently evaluating the data and preparing preliminary results. For the resistive exercise modality, MED-2 demonstrated a range of constant resistive loads from 10-150 lbf. With a displacement range of 84 inches, the MED-2 accommodates users from 5th percentile Japanese female through 95th percentile American male for all of its certified exercises. The displacement measurement accuracy has also been verified within 2.5 percent full range. The crew was able to successfully perform all prescribed resistive exercises, except Goblet Squats which were not feasible with a constant load profile. For the aerobic exercise modality, MED-2 simulated a rowing motion with prescribed and user-selected resistance levels. It has demonstrated rates up to 60 strokes per minute on the ground. MED-2 loads and displacements performance are the same as those cited for the resistive modality. Although each of the crew was able to perform the prescribed aerobic rowing sets, there was considerable variability in the rowing motion among different crewmembers. Also, as expected, the crew was unable to get the full benefits of a typical terrestrial rowing stroke because the current configuration does not allow the user to reach past their feet. These observations have already informed the requirements for other microgravity rowing devices currently in development. One of the unique features of the MED-2 device is the intuitive touch-screen control system. This One Portal graphical user interface (GUI) was developed based on JSC/ER’s heritage knowledge and experience of developing and sustaining the current ISS exercise equipment. Through this interface, the crew easily performed prepared prescriptions as well as had the ability to adjust exercise modality, load and other exercise details such as number of repetitions and number of sets. This touch-screen and GUI fulfilled the MED-2 project goal to simplify the interaction between the user and the device. Furthermore, the extent to which MED-2 utilizes a touchscreen and GUI to control exercise equipment is unmatched among the existing ISS exercise devices. As a motorized device, MED-2 technology can provide a customizable force profile that can be varied as a function of strap displacement, strap velocity or a combination of these and other variables. During 2017, JSC/ER developed and flight-certified a resistive exercise algorithm that mimics the 1-G inertial effects of free-weights and enables adjustable eccentric-to-concentric loading ratios. Subsequent development will explore varying the load profiles and incorporating additional exercises beyond the current list of certified movements.

Exercise↗