Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electron Beam Collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Fast-ignition transport studies: Realistic electron source, integrated particle-in-cell and hydrodynamic modeling, imposed magnetic fields

Transport modeling of idealized, cone-guided fast ignition targets indicates the severe challenge posed by fast-electron source divergence. The hybrid particle-in-cell (PIC) code Zuma is run in tandem with the radiation-hydrodynamics code Hydra to model fast-electron propagation, fuel heating, and thermonuclear burn. The fast electron source is based on a 3D explicit-PIC laser-plasma simulation with the PSC code. This shows a quasi two-temperature energy spectrum and a divergent angle spectrum (average velocity-space polar angle of 52 Degree-Sign ). Transport simulations with the PIC-based divergence do not ignite for >1 MJ of fast-electron energy, for a modest (70 {mu}m) standoff distance from fast-electron injection to the dense fuel. However, artificially collimating the source gives an ignition energy of 132 kJ. To mitigate the divergence, we consider imposed axial magnetic fields. Uniform fields {approx}50 MG are sufficient to recover the artificially collimated ignition energy. Experiments at the Omega laser facility have generated fields of this magnitude by imploding a capsule in seed fields of 50-100 kG. Such imploded fields will likely be more compressed in the transport region than in the laser absorption region. When fast electrons encounter increasing field strength, magnetic mirroring can reflect a substantial fraction of them and reduce coupling to the fuel. A hollow magnetic pipe, which peaks at a finite radius, is presented as one field configuration which circumvents mirroring.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of Extinction Efficiency in the 8-GeV Mu2e Beam Line

A muon-to-electron conversion experiment at Fermilab, Mu2e, is being designed to probe for new physics beyond the standard model at mass scales up to 10{sup 4} TeV. For this experiment, the advance in experimental sensitivity will be four orders of magnitude when compared to existing data on charged lepton flavor violation. The muon beam will be produced by delivering a proton beam contained in short 100-ns bunches onto a muon production target, with an inter-bunch separation of about 1700 ns. A critical requirement of the experiment is to ensure a low level of background at the muon detector consistent with the required sensitivity. To meet the sensitivity requirement, protons that reach the target between bunches must be suppressed by an enormous factor, so that an extinction factor, defined as a number of background protons between main bunches per proton in such a bunch, should not exceed 10{sup -9}. This paper describes the advanced beam optics and results of numerical modeling with STRUCT and MARS codes for a beam line with a collimation system that allows us to achieve the experimental extinction factor of one per billion.

43 PARTICLE ACCELERATORS↗

Transverse Emittance Reduction with Tapered Foil

The idea of reducing transverse emittance with tapered energy-loss foil is proposed by J.M. Peterson in 1980s and recently by B. Carlsten. In this paper, we present the physical model of tapered energy-loss foil and analyze the emittance reduction using the concept of eigen emittance. The study shows that, to reduce transverse emittance, one should collimate at least 4% of particles which has either much low energy or large transverse divergence. The multiple coulomb scattering is not trivial, leading to a limited emittance reduction ratio. Small transverse emittances are of essential importance for the accelerator facilities generating free electron lasers, especially in hard X-ray region. The idea of reducing transverse emittance with tapered energy-loss foil is recently proposed by B. Carlsten [1], and can be traced back to J.M. Peterson's work in 1980s [2]. Peterson illustrated that a transverse energy gradient can be produced with a tapered energy-loss foil which in turn leads to transverse emittance reduction, and also analyzed the emittance growth from the associated multiple coulomb scattering. However, what Peterson proposed was rather a conceptual than a practical design. In this paper, we build a more complete physical model of the tapered foil based on Ref. [2], including the analysis of the transverse emittance reduction using the concept of eigen emittance and confirming the results by various numerical simulations. The eigen emittance equals to the projected emittance when there is no cross correlation in beam's second order moments matrix [3]. To calculate the eigen emittances, it requires only to know the beam distribution at the foil exit. Thus, the analysis of emittance reduction and the optics design of the subsequent beam line section can be separated. In addition, we can combine the effects of multiple coulomb scattering and transverse energy gradient together in the beam matrix and analyze their net effect. We find that,when applied to an electron linac or electron beam line, the energy spread increase and angular growth due to multiple scattering are not trivial; as a result, the transverse emittance can only be reduced with a limited ratio, e.g. down to about 65% the original value. The contents of this paper are arranged as follows. In Sec. II, we build the physical model of the tapered foil, derive the transverse eigen emittance and discuss the emittance reduction criteria. In Sec. III, we implement numerical simulations to verify the physical model; and in Sec. IV, we present numerical experiments and subsequent beam line to remove the transverse energy gradient to demonstrate the applicability of such method. Conclusions are given in the last section.

43 PARTICLE ACCELERATORS↗

An MLC calibration method using a detector array

Purpose: The authors have developed a quantitative calibration method for a multileaf collimator (MLC) which measures individual leaf positions relative to the MLC backup jaw on an Elekta Synergy linear accelerator. Methods: The method utilizes a commercially available two-axis detector array (Profiler 2; Sun Nuclear Corporation, Melbourne, FL). To calibrate the MLC bank, its backup jaw is positioned at the central axis and the opposing jaw is retracted to create a half-beam configuration. The position of the backup jaws field edge is then measured with the array to obtain what is termed the radiation defined reference line. The positions of the individual leaf ends relative to this reference line are then inferred by the detector response in the leaf end penumbra. Iteratively adjusting and remeasuring the leaf end positions to within specifications completes the calibration. Using the backup jaw as a reference for the leaf end positions is based on three assumptions: (1) The leading edge of an MLC leaf bank is parallel to its backup jaw's leading edge, (2) the backup jaw position is reproducible, and (3) the measured radiation field edge created by each leaf end is representative of that leaf's position. Data from an electronic portal imaging device (EPID) were used in a similar analysis to check the results obtained with the array. Results: The relative leaf end positions measured with the array differed from those measured with the EPID by an average of 0.11 {+-}0.09 mm per leaf. The maximum leaf positional change measured with the Profiler 2 over a 3 month period was 0.51 mm. A leaf positional accuracy of {+-}0.4 mm is easily attainable through the iterative calibration process. The method requires an average of 40 min to measure both leaf banks. Conclusions: This work demonstrates that the Profiler 2 is an effective tool for efficient and quantitative MLC quality assurance and calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-TeP4-03: A Multileaf Collimator Calibration and Quality Assurance Technique Using An Electronic Portal Imaging Device

Purpose: To develop an accurate and quick multileaf collimator (MLC) calibration and quality assurance technique using an electronic portal imaging device (EPID) Methods: The MLC models used include the MLCi and Agility (Elekta Ltd). This technique consists of two 22(L)x10(W) cm{sup 2} fields with 0{sup 0} and 180{sup 0} collimator angles centered to an offset EPID. The MLC opening is estimated by calculating the profile at the image’s center in the image’s horizontal direction. Scans in the image’s vertical direction were calculated every 20 pixels in the inner 70% of estimated MLC opening. The profiles’ edges were fitted with linear equations to determine the image’s rotation angle. Then, crossline profiles were scanned at the center of each leaf taking into account the leaf’s width at isocenter and the rotation angle. The profiles’ edges determine the location of the leaves’ edges and these were subtracted from the reference leaf’s position in order to determine the relative leaf offsets. The edge location of all profiles was determined by using the parameterized gradient of the penumbra region. The technique was tested against an established diode array-based method, and for different MLC systems, patterns, gantry angles, days, energies, beam modalities and MLC openings. Results: The differences between the proposed and established methods were 0.26±0.19mm. The leaf offsets’ deviation was <0.3mm (5 months period). For pattern fields, the differences between predetermined and calculated offsets were 0.18±0.18mm. The leaf offset deviation of measurements with different energies and MLC openings were <0.1mm and <0.3mm, respectively. The differences between offsets of FF and FFF beams were 0.01±0.02mm (<0.07mm). The differences between the offsets at different gantry angles were 0.08±0.15mm. Conclusion: The proposed method proved to be accurate and efficient in calculating the relative leaf offsets. Parameterized field edge is essential to obtain accurate result by eliminating the noise from EPID.

60 APPLIED LIFE SCIENCES↗

EPID-based verification of the MLC performance for dynamic IMRT and VMAT

Purpose: In advanced radiotherapy treatments such as intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT), verification of the performance of the multileaf collimator (MLC) is an essential part of the linac QA program. The purpose of this study is to use the existing measurement methods for geometric QA of the MLCs and extend them to more comprehensive evaluation techniques, and to develop dedicated robust algorithms to quantitatively investigate the MLC performance in a fast, accurate, and efficient manner. Methods: The behavior of leaves was investigated in the step-and-shoot mode by the analysis of integrated electronic portal imaging device (EPID) images acquired during picket fence tests at fixed gantry angles and arc delivery. The MLC was also studied in dynamic mode by the analysis of cine EPID images of a sliding gap pattern delivered in a variety of conditions including different leaf speeds, deliveries at fixed gantry angles or in arc mode, and changing the direction of leaf motion. The accuracy of the method was tested by detection of the intentionally inserted errors in the delivery patterns. Results: The algorithm developed for the picket fence analysis was able to find each individual leaf position, gap width, and leaf bank skewness in addition to the deviations from expected leaf positions with respect to the beam central axis with sub-pixel accuracy. For the three tested linacs over a period of 5 months, the maximum change in the gap width was 0.5 mm, the maximum deviation from the expected leaf positions was 0.1 mm and the MLC skewness was up to 0.2 Degree-Sign . The algorithm developed for the sliding gap analysis could determine the velocity and acceleration/deceleration of each individual leaf as well as the gap width. There was a slight decrease in the accuracy of leaf performance with increasing leaf speeds. The analysis results were presented through several graphs. The accuracy of the method was assessed as 0.01 mm for both the gap size and peak position determination. Conclusions: This study provides fast, easy, and accurate test methods for routine QA of the MLC performance and helps in faster troubleshooting of MLC problems in both IMRT and VMAT treatments.

60 APPLIED LIFE SCIENCES↗

MCTP system model based on linear programming optimization of apertures obtained from sequencing patient image data maps

Purpose: The authors present a hybrid direct multileaf collimator (MLC) aperture optimization model exclusively based on sequencing of patient imaging data to be implemented on a Monte Carlo treatment planning system (MC-TPS) to allow the explicit radiation transport simulation of advanced radiotherapy treatments with optimal results in efficient times for clinical practice. Methods: The planning system (called CARMEN) is a full MC-TPS, controlled through aMATLAB interface, which is based on the sequencing of a novel map, called “biophysical” map, which is generated from enhanced image data of patients to achieve a set of segments actually deliverable. In order to reduce the required computation time, the conventional fluence map has been replaced by the biophysical map which is sequenced to provide direct apertures that will later be weighted by means of an optimization algorithm based on linear programming. A ray-casting algorithm throughout the patient CT assembles information about the found structures, the mass thickness crossed, as well as PET values. Data are recorded to generate a biophysical map for each gantry angle. These maps are the input files for a home-made sequencer developed to take into account the interactions of photons and electrons with the MLC. For each linac (Axesse of Elekta and Primus of Siemens) and energy beam studied (6, 9, 12, 15 MeV and 6 MV), phase space files were simulated with the EGSnrc/BEAMnrc code. The dose calculation in patient was carried out with the BEAMDOSE code. This code is a modified version of EGSnrc/DOSXYZnrc able to calculate the beamlet dose in order to combine them with different weights during the optimization process. Results: Three complex radiotherapy treatments were selected to check the reliability of CARMEN in situations where the MC calculation can offer an added value: A head-and-neck case (Case I) with three targets delineated on PET/CT images and a demanding dose-escalation; a partial breast irradiation case (Case II) solved with photon and electron modulated beams (IMRT + MERT); and a prostatic bed case (Case III) with a pronounced concave-shaped PTV by using volumetric modulated arc therapy. In the three cases, the required target prescription doses and constraints on organs at risk were fulfilled in a short enough time to allow routine clinical implementation. The quality assurance protocol followed to check CARMEN system showed a high agreement with the experimental measurements. Conclusions: A Monte Carlo treatment planning model exclusively based on maps performed from patient imaging data has been presented. The sequencing of these maps allows obtaining deliverable apertures which are weighted for modulation under a linear programming formulation. The model is able to solve complex radiotherapy treatments with high accuracy in an efficient computation time.

60 APPLIED LIFE SCIENCES↗

Resonant and random excitations on the proton beam in the Large Hadron Collider for active halo control with pulsed hollow electron lenses

We present the results of numerical simulations and experimental studies about the effects of resonant and random excitations on proton losses, emittances, and beam distributions in the Large Hadron Collider (LHC). In addition to shedding light on complex nonlinear effects, these studies are applied to the design of hollow electron lenses (HEL) for active beam halo control. In the High-Luminosity Large Hadron Collider (HL-LHC), a considerable amount of energy will be stored in the beam tails. To control and clean the beam halo, the installation of two hollow electron lenses, one per beam, is being considered. In standard electron-lens operation, a proton bunch sees the same electron current at every revolution. Pulsed electron beam operation (i.e., different currents for different turns) is also considered, because it can widen the range of achievable halo removal rates. For an axially symmetric electron beam, only protons in the halo are excited. If a residual field is present at the location of the beam core, these particles are exposed to time-dependent transverse kicks and to noise. We discuss the numerical simulations and the experiments conducted in 2016 and 2017 at injection energy in the LHC. The excitation patterns were generated by the transverse feedback and damping system, which acted as a flexible source of dipole kicks. Proton beam losses, emittances, and transverse distributions were recorded as a function of excitation patterns and strengths. The resonant excitations induced rich dynamical effects and nontrivial changes of the beam distributions, which, to our knowledge, have not previously been observed and studied in this detail. We conclude with a discussion of the tolerable and achievable residual fields and proposals for further studies.

43 PARTICLE ACCELERATORS↗

2D lag and signal nonlinearity correction in an amorphous silicon EPID and their impact on pretreatment dosimetric verification

Purpose: This investigation provides measurements of signal lag and nonlinearity separately for the Varian aS500 electronic portal imaging device (EPID), and an algorithm to correct for these effects in 2D; their potential impact on intensity modulated radiation therapy (IMRT) verification is also investigated. The authors quantify lag, as a function of both delivered monitor units (MU) and time, by using a range of MUs delivered at a clinically used rate of 400 MU/min. Explicit cumulative lag curves are thus determined for a range of MUs and times between the end of irradiation and the end of image acquisition. Signal nonlinearity is also investigated as a function of total MUs delivered. The family of cumulative lag curves and signal nonlinearity are then used to determine their effects on dynamic multileaf collimator (MLC) (IMRT) deliveries, and to correct for theses effects in 2D. Methods: Images acquired with an aS500 EPID and Varis Portal-Vision software were used to quantify detector lag and signal-nonlinearity. For the signal lag investigation, Portal-Vision's service monitor was used to acquire EPID images at a rate of 8 frames/s. The images were acquired during irradiation and 66 s thereafter, by inhibiting the M-holdoff-In signal of the Linac for a range of 4.5-198.5 MUs. Relative cumulative lag was calculated by integrating the EPID signal for a time after beam-off, and normalizing this to the integrated EPID signal accumulated during radiation. Signal nonlinearity was studied by acquiring 10 Multiplication-Sign 10 cm{sup 2} open-field EPID images in 'integrated image' mode for a range of 2-500 MUs, and normalized to the 100 MU case. All data were incorporated into in-house written software to create a 2D correction map for these effects, using the field's MLC file and a field-specific calculated 2D 'time-map,' which keeps track of the time elapsed from the last fluence delivered at each given point in the image to the end of the beam delivery. Results: Relative cumulative lag curves reveal that the lag alone can deviate the EPID's perceived dose by as large as 6% (1 MU delivery, 60 s postirradiation). For signal nonlinearity relative to 100 MU, EPID signals per MU of 0.84 and 1.01 were observed for 2 and 500 MUs, respectively. Correction maps were applied to a 1 cm sweeping-window 14 Multiplication-Sign 14 cm{sup 2} field and clinical head-and-neck IMRT field. A mean correction of 1.028 was implemented in the head-and-neck field, which significantly reduced lag-related asymmetries in the EPID images, and restored linearity to the EPID imager's dose response. Corrections made to the sweeping-field showed good agreement with the treatment planning system-predicted field, yielding an average percent difference of 0.05%{+-} 0.91%, compared to the -1.32%{+-} 1.02% before corrections, or 1.75%{+-} 1.04% when only a signal nonlinearity correction is made. Conclusions: Lag and signal-nonlinearity have been quantified for an aS500 EPID imager, and an effective 2D correction method has been developed which effectively removes nonlinearity and lag effects. Both of these effects were shown to negatively impact IMRT verifications. Especially fields that involve prolonged irradiation and small overall MUs should be corrected for in 2D.

60 APPLIED LIFE SCIENCES↗

NASA Tech Briefs, May 2008

Topics covered inclde: Deployable Wireless Camera Penetrators; Hand-Held Units for Short-Range Wireless Biotelemetry; Wearable Wireless Telemetry System for Implantable BioMEMS Sensors; Electronic Escape Trails for Firefighters; Architecture for a High-to-Medium-Voltage Power Converter; 24-Way Radial Power Combiner/Divider for 31 to 36 GHz; Three-Stage InP Submillimeter-Wave MMIC Amplifier; Fast Electromechanical Switches Based on Carbon Nanotubes; Solid-State High-Temperature Power Cells; Fast Offset Laser Phase-Locking System; Fabricating High-Resolution X-Ray Collimators; Embossed Teflon AF Laminate Membrane Microfluidic Diaphragm Valves; Flipperons for Improved Aerodynamic Performance; System Estimates Radius of Curvature of a Segmented Mirror; Refractory Ceramic Foams for Novel Applications; Self-Deploying Trusses Containing Shape-Memory Polymers; Fuel-Cell Electrolytes Based on Organosilica Hybrid Proton Conductors; Molecules for Fluorescence Detection of Specific Chemicals; Cell-Detection Technique for Automated Patch Clamping; Redesigned Human Metabolic Simulator; Compact, Highly Stable Ion Atomic Clock; LiGa(OTf)(sub 4) as an Electrolyte Salt for Li-Ion Cells; Compact Dielectric-Rod White-Light Delay Lines; Single-Mode WGM Resonators Fabricated by Diamond Turning; Mitigating Photon Jitter in Optical PPM Communication; MACOS Version 3.31; Fiber-Optic Determination of N2, O2, and Fuel Vapor in the Ullage of Liquid-Fuel Tanks; Spiking Neurons for Analysis of Patterns; Symmetric Phase-Only Filtering in Particle-Image Velocimetry; Efficient Coupler for a Bessel Beam Dispersive Element; and Attitude and Translation Control of a Solar Sail Vehicle.

Source record↗

Beam delivery and final focus systems for multi-TeV advanced linear colliders

The Beam Delivery System (BDS) is a critical component of a high-energy linear collider. It transports the beam from the accelerator and brings it to a focus at the Interaction Point. The BDS system includes diagnostic sections for measuring the beam energy, emittance, and polarization, as well as collimators for machine protection. The length of the BDS increases with collision energy. Higher collision energies also require higher luminosities, and this is a significant constraint on the design for energy-frontier machines. Here, we review BDS designs based on traditional quadrupole magnets and examine the challenges involved in extending these to the Multi-TeV regime consistent with requirements for advanced accelerator concepts.

43 PARTICLE ACCELERATORS↗

Wide-Field Optic for Autonomous Acquisition of Laser Link

An innovation reported in Two-Camera Acquisition and Tracking of a Flying Target, NASA Tech Briefs, Vol. 32, No. 8 (August 2008), p. 20, used a commercial fish-eye lens and an electronic imaging camera for initially locating objects with subsequent handover to an actuated narrow-field camera. But this operated against a dark-sky background. An improved solution involves an optical design based on custom optical components for the wide-field optical system that directly addresses the key limitations in acquiring a laser signal from a moving source such as an aircraft or a spacecraft. The first challenge was to increase the light collection entrance aperture diameter, which was approximately 1 mm in the first prototype. The new design presented here increases this entrance aperture diameter to 4.2 mm, which is equivalent to a more than 16 times larger collection area. One of the trades made in realizing this improvement was to restrict the field-of-view to +80 deg. elevation and 360 azimuth. This trade stems from practical considerations where laser beam propagation over the excessively high air mass, which is in the line of sight (LOS) at low elevation angles, results in vulnerability to severe atmospheric turbulence and attenuation. An additional benefit of the new design is that the large entrance aperture is maintained even at large off-axis angles when the optic is pointed at zenith. The second critical limitation for implementing spectral filtering in the design was tackled by collimating the light prior to focusing it onto the focal plane. This allows the placement of the narrow spectral filter in the collimated portion of the beam. For the narrow band spectral filter to function properly, it is necessary to adequately control the range of incident angles at which received light intercepts the filter. When this angle is restricted via collimation, narrower spectral filtering can be implemented. The collimated beam (and the filter) must be relatively large to reduce the incident angle down to only a few degrees. In the presented embodiment, the filter diameter is more than ten times larger than the entrance aperture. Specifically, the filter has a clear aperture of about 51 mm. The optical design is refractive, and is comprised of nine custom refractive elements and an interference filter. The restricted maximum angle through the narrow-band filter ensures the efficient use of a 2-nm noise equivalent bandwidth spectral width optical filter at low elevation angles (where the range is longest), at the expense of less efficiency for high elevations, which can be tolerated because the range at high elevation angles is shorter. The image circle is 12 mm in diameter, mapped to 80 x 360 of sky, centered on the zenith.

Page, Norman A.↗

WE-AB-BRB-03: Investigation of a Small Photomultiplier-Based Probe for Use in Beam Diagnostics and Medical Dosimetry

Purpose: Investigate the use of a small photomultiplier-based probe as a possible beam diagnostic and medical dosimetry tool. Methods: Cerenkov emission produced by clinical accelerator beams was detected by a small photomultiplier tube (PMT). Measurements of Clinac beams were made both in air and by inserting the PMT directly into a water phantom. A conical collimator placed in front of the PMT reduced the angular acceptance and the detection of scattered light. With this arrangement, we obtained response curves as a function of depth along the central axis similar in shape and magnitude to those obtained with ionization chambers. Subsequent measurements were made with the PMT covered in aluminum foil, obtaining a signal arising primarily from direct Cerenkov light produced in the glass entrance window. With an oscilloscope and amplifier/MCA system, we were able to monitor the response to individual beam pulses and observe variations in the beam pulse shape and magnitude as a function of dose rate. Results: Using Cerenkov signals detected by a PMT, we were able to obtain reasonable beam quality metrics, and the response was found to be linear over a range of dose rates. The fast response of the PMT allowed for the observation of small changes in the shape and magnitude of the beam pulse. With this system we were able to detect small changes in the dose per pulse delivered by the accelerator. Conclusion: A small PMT probe has shown promise as a beam diagnostic and medical dosimetry tool. Its fast response allows for real time beam pulse monitoring, and the integrated response can yield relative and perhaps even absolute dose information with a properly calibrated system. For accelerator diagnostics, monitoring of the beam pulse shape can aid in beam tuning, particularly in electron mode, where no target current pulse is available.

60 APPLIED LIFE SCIENCES↗

Coarse spectral characterization of warm x-rays at the Z facility using a filtered thermoluminescent dosimeter array

A new collimated filtered thermoluminescent dosimeter (TLD) array has been developed at the Z facility to characterize warm x-rays (hν > 10 keV) produced by Z pinch radiation sources. This array includes a Kapton debris shield assembly to protect the TLDs from the source debris, a collimator array to limit the field of view of the TLDs to the source region, a filter wheel containing filters of aluminum, copper and tungsten up to 3 mm thick to independently filter each TLD, and a hermetically sealed cassette containing the TLDs as well as tungsten shielding on the sides and back of the array to minimize scattered radiation reaching the TLDs. Here experimental results from a krypton gas puff and silver wire array shot are analyzed using two different functional forms of the energy spectrum to demonstrate the ability of this diagnostic to consistently extend the upper end of the x-ray spectrum characterization from ~50 keV to >1 MeV.

47 OTHER INSTRUMENTATION↗

SU-E-T-595: Design of a Graphical User Interface for An In-House Monte Carlo Based Treatment Planning System: Planning and Contouring Tools

Purpose: An in-house Monte Carlo based treatment planning system (MC TPS) has been developed for modulated electron radiation therapy (MERT). Our preliminary MERT planning experience called for a more user friendly graphical user interface. The current work aimed to design graphical windows and tools to facilitate the contouring and planning process. Methods: Our In-house GUI MC TPS is built on a set of EGS4 user codes namely MCPLAN and MCBEAM in addition to an in-house optimization code, which was named as MCOPTIM. Patient virtual phantom is constructed using the tomographic images in DICOM format exported from clinical treatment planning systems (TPS). Treatment target volumes and critical structures were usually contoured on clinical TPS and then sent as a structure set file. In our GUI program we developed a visualization tool to allow the planner to visualize the DICOM images and delineate the various structures. We implemented an option in our code for automatic contouring of the patient body and lungs. We also created an interface window displaying a three dimensional representation of the target and also showing a graphical representation of the treatment beams. Results: The new GUI features helped streamline the planning process. The implemented contouring option eliminated the need for performing this step on clinical TPS. The auto detection option for contouring the outer patient body and lungs was tested on patient CTs and it was shown to be accurate as compared to that of clinical TPS. The three dimensional representation of the target and the beams allows better selection of the gantry, collimator and couch angles. Conclusion: An in-house GUI program has been developed for more efficient MERT planning. The application of aiding tools implemented in the program is time saving and gives better control of the planning process.

60 APPLIED LIFE SCIENCES↗

The sensitivity of patient specific IMRT QC to systematic MLC leaf bank offset errors

Purpose: Patient specific IMRT QC is performed routinely in many clinics as a safeguard against errors and inaccuracies which may be introduced during the complex planning, data transfer, and delivery phases of this type of treatment. The purpose of this work is to evaluate the feasibility of detecting systematic errors in MLC leaf bank position with patient specific checks. Methods: 9 head and neck (H and N) and 14 prostate IMRT beams were delivered using MLC files containing systematic offsets ({+-}1 mm in two banks, {+-}0.5 mm in two banks, and 1 mm in one bank of leaves). The beams were measured using both MAPCHECK (Sun Nuclear Corp., Melbourne, FL) and the aS1000 electronic portal imaging device (Varian Medical Systems, Palo Alto, CA). Comparisons with calculated fields, without offsets, were made using commonly adopted criteria including absolute dose (AD) difference, relative dose difference, distance to agreement (DTA), and the gamma index. Results: The criteria most sensitive to systematic leaf bank offsets were the 3% AD, 3 mm DTA for MAPCHECK and the gamma index with 2% AD and 2 mm DTA for the EPID. The criterion based on the relative dose measurements was the least sensitive to MLC offsets. More highly modulated fields, i.e., H and N, showed greater changes in the percentage of passing points due to systematic MLC inaccuracy than prostate fields. Conclusions: None of the techniques or criteria tested is sufficiently sensitive, with the population of IMRT fields, to detect a systematic MLC offset at a clinically significant level on an individual field. Patient specific QC cannot, therefore, substitute for routine QC of the MLC itself.

60 APPLIED LIFE SCIENCES↗

EMAPS: An Efficient Multiscale Approach to Plasma Systems with Non-MHD Scale Effects

Global interactions of energetic ions with magnetoplasmas and neutral gases lie at the core of many space and laboratory plasma phenomena ranging from solar wind entry into and transport within planetary magnetospheres and exospheres to fast-ion driven instabilities in fusion devices to astrophysics-in-lab experiments. The ability of computational models to properly account for physical effects that underlie such interactions, namely ion kinetic, ion cyclotron, Hall, collisional and ionization processes is important for the success and planning of experimental research in plasma physics. Understanding the physics of energetic ions, in particular their nonlinear resonance interactions with Alfvén waves, is central to improving the heating performance of magnetically confined plasmas for future energy generation. Fluid models are not adequate for high-beta plasmas as they cannot fully capture ion kinetic and cyclotron physics (e.g., ion behavior in the presence of magnetic nulls, shock structures, plasma interpenetration, etc.). Recent results from global reconnection simulations show that even in a MHD-like regime there may be significant differences between kinetic and MHD simulations. Therefore, kinetic modeling becomes essential for meeting modern day challenges in plasma physics. The hybrid approximation is an intermediate approximation between the fluid and fully kinetic approximations. It eliminates light waves, removes the electron inertial temporal and spatial scales from the problem and enables full-orbit ion kinetics. As a result, hybrid codes have become effective tools for exploring ion-scale driven phenomena associated with ion beams, shocks, reconnection and turbulence that control the large-scale behavior of laboratory and space magnetoplasmas. A number of numerical issues, however, make three-dimensional (3D) large-scale hybrid simulations of inhomogeneous magnetized plasmas prohibitively expensive or even impossible. To resolve these difficulties we have developed a novel Event-driven Multiscale Asynchronous Parallel Simulation (EMAPS) technology that replaces time stepping with self-adaptive update events. Local calculations are carried out only on an “as needed basis”. EMAPS (i) guarantees accurate and stable processing of physical variables in time accurate simulations, and (ii) eliminates unnecessary computation. Applying EMAPS to the hybrid model has resulted in the development of a unique parallel code, dimension-independent (compile-time-configurable) HYPERS (Hybrid Parallel Event-Resolved Simulator) that scales to hundreds of thousands of parallel processors. HYPERS advances electromagnetic fields and particles asynchronously on time scales determined by local physical laws and mesh properties. To achieve high computational accuracy in complex device geometries, HYPERS employs high-fidelity Cartesian grids with masked conductive cells. The HYPERS model includes multiple ion species, energy and momentum conserving ion-ion collisions, and provides a number of approximations for plasma resistivity and vacuum regions. Both local and periodic boundary conditions are allowed. The HYPERS solver preserves zero divergence of magnetic field. The project has demonstrated HYPERS capabilities on a number of applications of interest to fusion and astrophysical plasma physics applications listed below. 1. Theta-pinch formation of FRCs The formation, spontaneous spin-up, and stability of theta-pinch formed field-reversed configurations have been studied self-consistently in 3D. The end-to-end hybrid simulations reveal poloidal profiles of implosion-driven fast toroidal plasma rotation and demonstrate three discharge regimes as a function of experimental parameters: the decaying stable configuration, the tilt unstable configuration, and the nonlinear evolution of a fast growing tearing mode. 2. FRC collisions with magnetic mirrors Interactions of fast plasma streams and objects with magnetic obstacles (dipoles, mirrors, etc) lie at the core of many space and laboratory plasma phenomena ranging from magnetoshells and solar wind interactions with planetary magnetospheres to compact fusion plasmas. HYPERS simulations are compared with data from the MSX experiment (LANL) that focuses on the physics of magnetized collisionless shocks through the acceleration and subsequent stagnation of FRC plasmoids against a strong magnetic mirrors and flux-conserving boundaries. 3. Exploding magnetoplasmas Results from hybrid simulations of two experiments at the LAPD and Nevada Terawatt Facility are discussed where short-pulse lasers are used to ablate solid targets to produce plasmas that expand across external magnetic fields. The first simulation recreates flutelike density striations observed at the leading edge of a carbon plasma and predicts an early destruction of the magnetic cavity in agreement with experimental evidence. In the second simulation a polyethylene target is ablated into a mixture of protons and carbon ions. A mechanism is demonstrated that allows protons to penetrate the magnetic field in the form of a collimated flow. The results are compared to experimental data and single-fluid MHD simulations. The EMAPS framework has the potential for wide application in many other engineering and scientific fields, such as climate models, biological systems, electronic devices, seismic events, oil reservation simulators that all involve advancing solutions of partial differential equations in time where the rate of activity can be adapted widely over the spatial domain depending on locally space/time phenomena (“events”).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aligning Three Off-Axis Mirrors with Help of a DOE

A proposed method based on the use of a special-purpose diffractive optical element (DOE) would simplify (relative to prior methods) the alignment of three off-axis mirrors that constitute an imaging optical system. The method would exploit the fact that a DOE can be fabricated lithographically with high accuracy by electron-beam lithography in a thin film of poly(methyl methacrylate). The method would effectively transfer much of the problem of obtaining the needed accuracy from the mechanical-mirror-alignment domain to the lithographic domain. Unlike other methods that depend on specific symmetries (e.g., sphericity and/or concentricity), this method is expected to apply with equal ease and accuracy to mirrors of any configuration including aspherical, decentered mirrors. Assuming that one of the mirrors of a general three-mirror imaging optical system can serve as a reference for the alignment of the other two mirrors, such a system has 12 degrees of freedom in alignment. In the proposed method, one would use an interferometer in combination with a DOE to effect precise and relatively rapid and easy alignment of two of the mirrors with respect to each other, thus reducing the alignment task to that of the six degrees of freedom of the remaining mirror. The figure depicts a representative three-mirror off-axis imaging system, wherein the primary and tertiary mirrors (M1 and M3, respectively) are concave and the secondary mirror (M2) is convex. The DOE for aligning this system would be fabricated on the right surface of an optical flat and could be made to have either negative or positive focusing power, depending on the requirements of the specific application. The DOE could be designed to be placed at any convenient distance from M1 and M3 - again, depending on the application. The DOE would be illuminated with light coming from the left, generated by an interferometer. First, assuming the optical flat is of high quality, the plane of the DOE would be aligned perpendicular to the collimated beam by use of light reflected from the left face of the optical flat. The DOE would comprise two independent areas: one dedicated to M1, the other to M3. The portions of the collimated beam passing through those areas would be diffracted towards the corresponding mirrors. A mask, not shown in the figure, could be used to prevent light from passing through the rest of the area of the optical flat. Light rays reflected from M1 and M3 would retrace their paths through the DOE and would propagate leftward to the interferometer.

Mouroulis, Pantazis↗