Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Assessment of Building Energy-Saving Policies and Programs in China During the 11th Five Year Plan

China's 11th Five-Year Plan (FYP) sets an ambitious target to reduce the energy intensity per unit of gross domestic product (GDP) by 20% from 2005 to 2010 (NDRC, 2006). In the building sector, the primary energy-saving target allocated during the 11 FYP period is 100 Mtce. Savings are expected to be achieved through the strengthening of enforcement of building energy efficiency codes, existing building retrofits and heat supply system reform, followed by energy management of government office buildings and large scale public buildings, adoption of renewable energy sources. To date, China has reported that it achieved the half of the 20% intensity reduction target by the end of 2008, however, little has been made clear on the status and the impact of the building programs. There has also been lack of description on methodology for calculating the savings and baseline definition, and no total savings that have been officially reported to date. This paper intends to provide both quantitative and qualitative assessment of the key policies and programs in building sector that China has instituted in its quest to fulfill the national goal. Overall, this paper concludes that the largest improvement for building energy efficiency were achieved in new buildings; the program to improve the energy management in government and large scale public buildings are in line with the target; however the progress in the area of existing building retrofits, particularly heating supply system reform lags behind the stated goal by a large amount.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Overview of Development and Deployment of Codes, Standards and Regulations Affecting Energy Storage System Safety in the United States

This report acquaints stakeholders and interested parties involved in the development and/or deployment of energy storage systems (ESS) with the subject of safety-related codes, standards and regulations (CSRs). It is hoped that users of this document gain a more in depth and uniform understanding of safety-related CSR development and deployment that can foster improved communications among all ESS stakeholders and the collaboration needed to realize more timely acceptance and approval of safe ESS technology through appropriate CSR.

Conover, David R.↗

Heating and Cooling Energy Modeling of 3D-Printed Concrete Construction of Residential Buildings [Slides]

3D printed concrete construction (C3DP) is an emerging technology that comes with the associated benefits of high thermal mass walls. We investigated using BEopt software the heating and cooling energy use of a single story C3DP-constructed house. We then compared the heating/cooling energy use of the C3DP house against the corresponding energy use in a traditional timber (wood) frame construction (WFC), as well as a concrete masonry unit (CMU) construction. Both peak energy use for heating and cooling (Btu), as well as base energy use for both heating and cooling (MMBtu/yr) of the C3DP design were compared against the WFC and CMU baseline construction of identical geometries and orientations across all eight climate zones defined in the International Energy Conservation Code (IECC). The BEopt models for all three constructions (C3DP, WFC, and CMU) were built to comply with the 2018 IECC code. Results indicate that C3DP construction has significant heating and cooling energy benefits in certain climate zones, with the highest peak cooling energy savings (9% compared to WFC, and 5% compared to CMU) in the IECC Climate Zone 1 in the month of July. The peak heating and cooling energy demand reduction of C3DP were found to be more significant than the base heating and cooling energy demand in all IECC climate zones. The 2018 IECC compliance-related U-Factor adjustments of all models also resulted in more peak energy savings of the C3DP design in the cooling-dominated climate zones (climate zones 1 and 2), moderate energy savings in moderate climate zones (climate zones 3, 4, and 6), and little to no change in energy savings in very cold climates (climate zones 7 and 8).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TES Design Code [SWR-17-16]

Thermal Energy Storage (TES) Design Code is intended as an engineering design tool for determining the necessary parameters in designing a phase change composite based thermal energy storage module(s). TES Design Code allows input of engineering and thermodynamic quantities, such as physical dimensions, thermal quantities (e.g. heat capacity and conductivity), heat transfer fluid properties and layout/circuiting of heat exchange tubes within a phase change composite.

Kozubal, Eric↗

Duct Insulation and Sealing Requirements in Commercial Buildings - Code Notes

Duct insulation and sealing, especially insulated supply ducts delivering conditioned air within a building, save energy. The intent of energy-efficiency codes, as related to duct insulation and sealing, is to keep mechanically warmed or cooled air as close to a constant, desired temperature as possible and prevent the conditioned air from escaping the duct system while it is being moved to spaces where it is needed. If reduced heat transfer through insulated ducts is accounted for in the heating, ventilating, and air conditioning (HVAC) load calculations, it may even be possible to reduce the size of HVAC equipment.

Duct systems, thermal envelope, conditioned air, H↗

Potential energy savings benefits and limitations of radiative cooling coatings for U.S. residential buildings

We report radiative coatings are a promising strategy to implement passive cooling that provides an eco-friendly pathway to achieve energy efficiency in buildings. This study investigates the benefits and limitations of implementing radiative coatings on the building envelope, particularly the roof, of residential buildings in the United States. The analysis compares the performance of an ideal radiative coating with broadband surface properties to a realistic radiative coating with diffuse and semitransparent properties. To enhance the net energy efficiency of buildings, we carried out a comprehensive parametric analysis comprising key radiation surface properties to maximize cooling energy savings while minimizing heating energy penalties. A countrywide assessment for 68 locations across the United States showed that net energy savings are a strong function of the climatic and atmospheric conditions. Broadly, southern locations showed high overall energy savings whereas northern locations exhibited high overall energy penalties. Locations in International Energy Conservation Code (IECC) climate zones 1A, 2A, and 2B showed a net annual energy savings above 5%, whereas locations in IECC climate zones 5B, 6B, and 7 showed a net annual energy penalty greater than 3%. The hot and dry climate of Phoenix, Arizona, showed the highest overall energy savings of 426 kWh (6.2%). Additionally, the mathematical correlation reveals that the net energy savings of a location is positive only when its average cooling degree days is greater than 5.5 or its average heating degree days is less than 10.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Technical Report: "Achieving Regional Energy Efficiency Potential in the Southeast”

The overall objective of this award was to facilitate sharing of DOE resources and best practices as well as provide technical assistance to key stakeholders to support greater compliance with energy efficiency standards and increased energy savings. The outcomes of this award include greater awareness among key stakeholders on energy efficiency topics, increased deployment and utilization of DOE resources, and effective policies and programs to support energy efficiency in the Southeast.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

2012 IECC Climate Zones

County mapping of the 2012 climate zones from the International Energy Conservation Code. Each county in the CONUS is assigned a temperature and moisture regime. This dataset contains the raw data, the mapped data in various formats, and plots of the output.

2012↗

Utah FORGE: Fault Reactivation Through Fluid Injection Induced Seismicity Laboratory Experiments

Included are results from shear reactivation experiments on laboratory faults pre-loaded close to failure and reactivated by the injection of fluid into the fault. The sample comprises a single-inclined-fracture (SIF) transecting a cylindrical sample of Westerly granite. All experiments are conducted at ambient temperature and follow a similar protocol: (i) application of confining stresses (3MPa) on the fault fully saturated with DI water, (ii) shear-mobilization through the increase of axial loading at a constant displacement rate until a post-peak steady-state condition is reached, (iii) reduction of axial loading and related shear stress to a prescribed fraction of the peak steady-state frictional strength (typically 60% to 90%, representing intermediate to high magnitudes) and (iv), fault reactivation triggered by a stepwise increase of pore pressure on the fault in 0.1 MPa increments held constant for 1-5 minutes. Mechanical data from three ISCO pumps connected to a Temco pressure vessel measure axial, confining, and fault-related parameters, including fluid pressure (kPa), fluid flow rate (mL/min), and axial displacement (mm). See included code for initial data analysis and visualization for select experiments. Resource names represent experiment numbers found in the "Read Me" file, which describes each experimental setup and parameters.

15 GEOTHERMAL ENERGY↗

Method for Determining Optimal Residential Energy Efficiency Retrofit Packages

Businesses, government agencies, consumers, policy makers, and utilities currently have limited access to occupant-, building-, and location-specific recommendations for optimal energy retrofit packages, as defined by estimated costs and energy savings. This report describes an analysis method for determining optimal residential energy efficiency retrofit packages and, as an illustrative example,applies the analysis method to a 1960s-era home in eight U.S. cities covering a range of International Energy Conservation Code (IECC) climate regions. The method uses an optimization scheme that considers average energy use (determined from building energy simulations) and equivalent annual cost to recommend optimal retrofit packages specific to the building, occupants, and location. Energysavings and incremental costs are calculated relative to a minimum upgrade reference scenario, which accounts for efficiency upgrades that would occur in the absence of a retrofit because of equipment wear-out and replacement with current minimum standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Method for Determining Optimal Residential Energy Efficiency Packages

This report describes an analysis method for determining optimal residential energy efficiency retrofit packages and, as an illustrative example, applies the analysis method to a 1960s-era home in eight U.S. cities covering a range of International Energy Conservation Code (IECC) climate regions. The method uses an optimization scheme that considers average energy use (determined from building energy simulations) and equivalent annual cost to recommend optimal retrofit packages specific to the building, occupants, and location.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance analysis and implementation details of the Energy Conserving Semi-Implicit Method code (ECsim)

We present in this work the implementation of the Energy Conserving Semi-Implicit Method in a parallel code called ECsim. This new code is a three-dimensional, fully electromagnetic particle in cell (PIC) code. It is written in C/C++ and uses MPI to allow massive parallelization. ECsim is unconditionally stable in time, eliminates the finite grid instability, and has the same cycle scheme as the explicit code with a computational cost comparable to other semi-implicit PIC codes. All these features make it a very valuable tool to address situations which have not been possible to analyze until now with other PIC codes. In this work, we show the details of the algorithm implementation and we study its performance in different systems. ECsim is compared with another semi-implicit PIC code with different time and spectral resolution, showing its ability to address situations where other codes fail.

97 MATHEMATICS AND COMPUTING↗

Calculation of thermodynamic functions of aluminum plasma for high-energy-density systems

The results of calculating the degree of ionization, the pressure, and the specific internal energy of aluminum plasma in a wide temperature range are presented. The TERMAG computational code based on the Thomas–Fermi model was used at temperatures T > 105 K, and the ionization equilibrium model (Saha model) was applied at lower temperatures. Quantitatively similar results were obtained in the temperature range where both models are applicable. This suggests that the obtained data may be joined to produce a wide-range equation of state.

74 ATOMIC AND MOLECULAR PHYSICS↗

National Energy Audit Tool for Multifamily Buildings — Development Plan

The U.S. Department of Energy's (DOE's) Weatherization Assistance Program (WAP) enables low-income families to reduce their energy costs by providing funds to make their homes more energy efficient. In addition, the program funds Weatherization Training and Technical Assistance (T and TA) activities to support a range of program operations. These activities include measuring and documenting performance, monitoring programs, promoting advanced techniques and collaborations to further improve program effectiveness, and training, including developing tools and information resources. The T and TA plan outlines the tasks, activities, and milestones to support the weatherization network with the program implementation ramp up efforts. Weatherization of multifamily buildings has been recognized as an effective way to ramp up weatherization efforts. To support this effort, the 2009 National Weatherization T and TA plan includes the task of expanding the functionality of the Weatherization Assistant, a DOE-sponsored family of energy audit computer programs, to perform audits for large and small multifamily buildings This report describes the planning effort for a new multifamily energy audit tool for DOE's WAP. The functionality of the Weatherization Assistant is being expanded to also perform energy audits of small multifamily and large multifamily buildings. The process covers an assessment of needs that includes input from national experts during two national Web conferences. The assessment of needs is then translated into capability and performance descriptions for the proposed new multifamily energy audit, with some description of what might or should be provided in the new tool. The assessment of needs is combined with our best judgment to lay out a strategy for development of the multifamily tool that proceeds in stages, with features of an initial tool (version 1) and a more capable version 2 handled with currently available resources. Additional development in the future is expected to be needed if more capabilities are to be added. A rough schedule for development of the version 1 tool is presented. The components and capabilities described in this plan will serve as the starting point for development of the proposed new multifamily energy audit tool for WAP.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings

While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Consortium for Advanced Residential Building's (CARB’s) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.

2012 IECC↗

Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings

​While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of CARB's multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.

&#8203↗

Response to FESAC survey, non-fusion connections to Fusion Energy Sciences. Applications of the FES-supported beam and plasma simulation code, Warp

The Fusion Energy Sciences Advisory Committee’s subcommittee on non-fusion applications (FESAC NFA) is conducting a survey to obtain information from the fusion community about non-fusion work that has resulted from their DOE-funded fusion research. The subcommittee has requested that members of the community describe recent developments connected to the activities of the DOE Office of Fusion Energy Sciences. Two questions in particular were posed by the subcommittee. This document contains the authors’ responses to those questions.

43 PARTICLE ACCELERATORS↗

A new multi-energy neutrino radiation-hydrodynamics code in full general relativity and its application to the gravitational collapse of massive stars

We present a new multi-dimensional radiation-hydrodynamics code for massive stellar core-collapse in full general relativity (GR). Employing an M1 analytical closure scheme, we solve spectral neutrino transport of the radiation energy and momentum based on a truncated moment formalism. Regarding neutrino opacities, we take into account a baseline set in state-of-the-art simulations, in which inelastic neutrino–electron scattering, thermal neutrino production via pair annihilation, and nucleon–nucleon bremsstrahlung are included. While the Einstein field equations and the spatial advection terms in the radiation-hydrodynamics equations are evolved explicitly, the source terms due to neutrino–matter interactions and energy shift in the radiation moment equations are integrated implicitly by an iteration method. To verify our code, we first perform a series of standard radiation tests with analytical solutions that include the check of gravitational redshift and Doppler shift. A good agreement in these tests supports the reliability of the GR multi-energy neutrino transport scheme. We then conduct several test simulations of core-collapse, bounce, and shock stall of a 15M{sub ⊙} star in the Cartesian coordinates and make a detailed comparison with published results. Our code performs quite well to reproduce the results of full Boltzmann neutrino transport especially before bounce. In the postbounce phase, our code basically performs well, however, there are several differences that are most likely to come from the insufficient spatial resolution in our current 3D-GR models. For clarifying the resolution dependence and extending the code comparison in the late postbounce phase, we discuss that next-generation Exaflops class supercomputers are needed at least.

79 ASTRONOMY AND ASTROPHYSICS↗