Search NASA⌕ Search

SEARCH · Search NASA

Results for “Environmental Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Fire Station #2, Former Sewage Treatment Plant #17, and Towway Area-SWMU 114 PFAS Site Assessment Progress Report Kennedy Space Center, Florida

This PFAS Site Assessment Progress Report (SAPR) presents the findings of the 2022 PFAS investigation conducted from November 2021 through August 2022 at Solid Waste Management Unit (SWMU) 114 located within Kennedy Space Center (KSC), Florida. SWMU 114 includes area around Fire Station #2, Former Sewage Treatment Plant #17, the southern portion of the Shuttle Landing Facility Runway, Remote Launch Vehicle Hangar, and the Towway area. Fire Station #2 was constructed in 2008 and is currently active, housing fire station personnel and equipment, including aqueous film forming foam (AFFF). Releases of AFFF has occurred at SWMU 114. Previous environmental assessments have been performed at SWMU 114, including soil, groundwater, and surface water sampling for volatile organic compounds, polycyclic aromatic hydrocarbons, total petroleum hydrocarbons, and metals. No active remediation has been performed at the SWMU 114. PFAS site assessment field activities were conducted at SWMU 114 from November 2021 through August 2022. During the 2021-2022 Site Assessment, 124 direct-push samples were collected from 27 locations, 17 surface water samples were collected from 15 locations, 41 groundwater samples were collected from 37 newly installed monitoring wells, five concrete samples were collected from four locations, and one asphalt sample was collected. Additionally, two soil borings were advanced to 60 feet for lithologic descriptions, ten staff gauges were installed, and one round of water level measurements were collected from monitoring wells and staff gauges for groundwater flow determination. All groundwater and surface water samples were analyzed for 25 PFAS analytes by USEPA Method 537M. Concrete, and asphalt samples were analyzed by synthetic precipitation leaching procedure (SPLP) PFAS analysis by USEPA Modified Method 537M. Groundwater results were compared to the most recent Regional Screening Levels (RSLs) published by USEPA for residential tap water (USEPA, 2022a) to determine the extent of PFAS contamination at SWMU 114 for six PFAS analytes (PFOA, PFNA, PFBS, PFHxS, PFOS, and GenX). Surface water results were compared to the FDEP surface water screening levels (SW SLs) (FDEP, 2020) for PFOA and PFOS. The PFAS investigation concluded that groundwater exceeding RSLs extends east and south to Banana Creek and west to approximately the center of the SLF runway. The extent of PFAS is approximated to the north, to an area between Sharkey Road and Astronaut Road, where samples below the RSLs do not fully bound SWMU 114. At least two distinct PFAS source areas are located near Fire Station #2 and along Towway, at S114-MW0007S, within SWMU 114. Groundwater head measurements indicate that flow at SWMU 114 is generally similar across the shallow and intermediate water tables. A northeast to southwest trending groundwater divide is located near the middle of Towway where groundwater southeast of the divide flows to the south and groundwater northwest of the divide flows to the west. The groundwater divide generally separates the two areas of higher PFAS concentrations. Surface water samples indicated concentrations of PFOS above the SW SLs in surface water bodies across the site. Further assessment and sampling are required to better understand the interaction between groundwater and surface water at SWMU 114. Concrete and asphalt samples collected confirm that a significant release of AFFF occurred near the stormwater pond northwest of Fire Station #2. Additional concrete samples surrounding Fire Station #2 and at the northwest and southeast edges of the SLF tarmac indicate elevated PFOS concentrations. These results indicate that discharges of AFFF in these locations have infiltrated into asphalt and concrete and may act as a continuing source of PFAS to groundwater and surface water after rain events. Additional direct-push samples are required to delineate PFAS at SWMU 114. Samples may need to extend beyond the Former SLF Rescue Building and Morpheous Test Site to delineate PFAS in groundwater. Monitoring wells should be sampled and gauged quarterly to determine if seasonal impacts are observable, especially in shallow wells near surface water features. Furthermore, surface water samples should be collected from additional ditches to further define the extent of surface water impacts at SWMU 114 and extending along the SLF runway. Staff gauges should be gauged quarterly with groundwater gauging to determine surface water flow and interaction with groundwater. The PFAS sampling results and path forward for SWMU 114 were presented to the KSC Remediation Team in October 2022. Once the PFAS SAPR is approved, it will be submitted to the Florida Department of Environmental Protection.

Howard Franklin Fowler↗

Identifying Neutron Irradiation in Space to Mitigate Bio-Medical Effects

One of the primary challenges to interplanetary human travel is mitigation of radiation expo-sure. As fast transit with LENR driven or conventional nuclear electric (NEP) or thermal propulsion (NTP) may be imminent, time and level of radiation exposure composingALARA (As Low as Rea-sonably Achievable) must be ascertained rapidly and precisely. Since acute physiological effects are difficult to detect, and chronic effects on crew health are delayed and potentially trans-generational, improved detection technologies will be game-changing and an essential element of the crew health monitoring and environmental protection toolkit.Secondary Galactic Cosmic Ray (GCR) induced neutrons are an additional hazard.

space medicine↗

Establishing Standardized Test Methods for Evaluating Space Suit Gloves

The Artemis space suit glove environmental protection garment (EPG) will be the first line of protection used to shield the crewmember’s hands from the environments encountered during extravehicular activity (EVA). As the Artemis missions will include more extreme environments than those experienced on the International Space Station, development, verification, and validation of gloves poses three key challenges. First, there are no standardized tests defined to evaluate the durability of space suit gloves for the extreme lunar environments, particularly the permanently shadowed regions. Second, there is insufficient data on state-of-the-art glove performance in a lunar environment from which to compare new designs. Third, current ISS glove Thermal Micrometeoroid Garment (TMG) fabrics are unlikely to be sufficient to meet Lunar requirements. It is therefore necessary to define tests to evaluate if gloves can meet new, challenging requirements. This paper focuses on the development of a test procedure to characterize lunar EVA glove fabrics using ASTM standardized test methods and the design and validation of a new standardized test procedure for comparing abrasion resistance between fabrics in lunar-like conditions. The results of testing on twelve candidate EVA glove fabrics are presented.

Robert J. Jones↗

Composite Hard Upper Torso (CHUT) for xEMU Space Suit

The xEMU is the Exploration Mobility Unity or space suit designed for microgravity (cislunar and low earth orbit (LEO)) and lunar surface operations. This suit design allows crewmembers to perform extravehicular exploration, science, construction, maintenance, and contingency operations while unattached to a vehicle for life support in pressure and thermal environments that exceed human capability. The xEMU provides life support, environmental protection, and communications capabilities to the EVA crewmember while allowing sufficient mobility and visibility to perform dexterous EVA tasks. The effort documented in this paper, addressed the design, analysis, manufacturing, full-scale test article testing and validation for a Composite Hard Upper Torso(CHUT)unit. Design and analysis of the CHUT was based on measured B-basis properties of the selected S-glass/epoxy composite, and established final geometry, composite layup and interface details that met requirements. A complete manufacturing and assembly protocol was established for the CHUT starting from composite layup in the tool, to final assembly of all interface metal hardware prior to delivery to NASA for suit integration. Full-scale CHUT test articles underwent static and fatigue pressure testing (2 lifetimes), impact testing at critical stress locations for tool drop/microgravity scenarios, followed by post-impact fatigue testing. Effect of manufacturing defects was evaluated by manufacturing a full-scale CHUT with 0.375”/0.5” defects at critical stress locations, followed by static and life-cycle fatigue testing. In all cases, the CHUT design met or exceeded mass, structural, interface and functional requirements. Two (2) complete CHUT articles were delivered to NASA for full-scale suit integration and testing.

spacesuit↗

Pacific Northwest Health & Air Quality: Monitoring Trends in Air Quality During a Drought Case Study to Improve Public Health Response to Drought Threats

Recent studies have documented a correlation between air quality and drought in the United States, which has been linked with increased aerosols including airborne particulate matter (PM) during drought conditions. This study partnered with local health departments to evaluate trends in air quality in the Pacific Northwest during the evolution of drought conditions using aerosol optical depth (AOD) observations collected by NASA’s Moderate Resolution Imaging Spectroradiometer (MODIS) sensor aboard the Terra and Aqua satellites. These satellite data were analyzed in conjunction with ground-based PM2.5 and PM10 data sourced from the Environmental Protection Agency (EPA)’s network of ground-based monitors and the Standardized Precipitation Evapotranspiration Index (SPEI) drought index. Based on recommendations by local health departments, this study examined air quality trends between 2015 and 2022 in 12 counties within Oregon and Washington that reflected diversity in population density, drought exposure, rural and urban status, and data availability from EPA monitors. Overall, results indicated variation in relationships among drought, satellite, and ground-based air quality data across the study area. This study did not control for the impact of wildfire events on air quality and also did not investigate shorter SPEI aggregation periods, both of which are avenues for future research. This project supplemented research into links between drought and human health and provided health departments with an objective foundation from which they can communicate public health risks to local communities.

Abby Sgan↗

Launch Complex 39B, SWMU 009 Air Sparging System Expansion Implementation Work Plan Kennedy Space Center, Florida

This Implementation Work Plan (IWP) for expansion of the Air Sparging (AS) system at Launch Complex 39B (LC39B), presents the design and coordination specifics to expand the existing AS Interim Measure (IM) at LC39B located at Kennedy Space Center (KSC), Florida. The existing AS system at LC39B was installed in 2017 and included 279 AS wells. LC39B has been designated as Solid Waste Management Unit (SWMU) 009 under the KSC Resource Conservation and Recovery Act (RCRA) Corrective Action Program. Expansion of the AS IM will include installation of an additional five AS wells to depths of approximately 13 and 17 feet below land surface (bls) to remediate contaminated groundwater identified northwest of the launch pad, near the liquid oxygen (LOX) tank. The expansion will target concentrations of cis-1,2-dichloroethene (cDCE) and vinyl chloride (VC) greater than Florida Department of Environmental Protection (FDEP) Natural Attenuation Default Concentrations (NADCs) that were identified during direct push technology (DPT) sampling events between 2019-2022 in shallow intervals between 8 and 16 feet bls. The objective for this expansion is to remediate contaminated groundwater within the treatment zone to below NADCs to support transition to monitored natural attenuation (MNA) through a long-term monitoring (LTM) program. This expansion will treat approximately 0.07-acres of residual groundwater contamination. The IWP design for this expansion will utilize the existing AS system trailer that is already onsite and operating. The five new AS expansion wells will be integrated into the existing Zone Z4 distribution manifold to deliver compressed air to the new AS wells. To deliver airflow, three existing lateral lines will be split in the field at a lateral split junction point (using 2-way or 3-way splits). Each split lateral will supply air to AS wells at the same depth interval to minimize preferential pathways. The trenching layout for the new AS wells was developed to minimize ground disturbance due to the amount of utilities in the area. One new monitoring well will also be installed and added to LC39B’s performance monitoring program to evaluate the effectiveness of the AS system expansion. This well will be sampled on a semi-annual basis for volatile organic compounds, with results evaluated to determine if system adjustments may be required. The main components of this IWP were presented to the KSC Remediation Team (KSCRT) at the October 2022 Meeting (Meeting 2210-M05). DPT delineation data from the LOX area were also presented, which included some inferred boundaries due to physical restrictions of the LOX tank and associated concrete pad and infrastructure. Planned monitoring well sampling in this area will help determine if back-diffusion may be occurring from beneath the pad. Additionally, based on potential petroleum odors and staining identified at two DPT locations during the January 2022 DPT event in the 10-16 feet bls range, a KSCRT action item was assigned during the October 2022 meeting to collect soil samples for petroleum compounds if similar odors or staining are identified during IM implementation. Construction completion and performance monitoring will be incorporated into LC39B’s groundwater monitoring reports, which are currently submitted on an annual basis to FDEP to document operation and maintenance activities and results from the AS IM.

Deborah M. Wilson↗

Monitoring Trends in Air Quality During a Drought: Case Study to Improve Public Health Response to Drought Threats

Drought has been an area of distinct concern in the Pacific Northwest since the mid-2010s. Recent studies have documented a correlation between air quality and drought in the United States, which is often observed in increased aerosols including airborne particulate matter (PM). This study partnered with the Oregon Health Authority and Washington State Department of Health to evaluate trends in air quality in the Pacific Northwest during the evolution of drought conditions using aerosol optical depth (AOD) observations collected by NASA’s Moderate Resolution Imaging Spectroradiometer (MODIS) sensor aboard the Terra and Aqua satellites. These satellite data were analyzed in conjunction with ground-based PM2.5 and PM10 data sourced from the Environmental Protection Agency (EPA) Air Quality System’s network of ground-based monitors and the Standardized Precipitation Evapotranspiration Index drought index. Based on recommendations by local health departments, this study examined air quality trends between 2015 and 2022 in 12 counties within Oregon and Washington that reflected diversity in population density, drought exposure, rural and urban status, and data availability from EPA AQS monitors. The findings from this study provided supplemental information to the ongoing efforts by community health stakeholders to study the public health impacts of drought and support public health responses to future drought events.

Taylor West↗

Shallow Soil Polychlorinated Biphenyl Site Assessment Report

This report presents a summary of the shallow soil polychlorinated biphenyl (PCB) site assessment activities that occurred from December 2020 through July 2022 at General Services Administration Reclamation Yard, Solid Waste Management Unit (SWMU) 010, located at the John F. Kennedy Space Center (KSC), Florida. The site is monitored under KSC’s Resource Conservation and Recovery Act Corrective Action Program, which also meets the requirements of Chapter 62-780, Florida Administrative Code. For the purposes of this report, three separate shallow soil plumes, known as the Northeast Shallow Soil PCB Plume, Southeast Shallow Soil PCB Plume, and West Shallow Soil PCB Plume, were identified for this site. The activities presented in this report include seven field events conducted between December 2020 and July 2022, which include shallow soil sample collection in the Northeast, Southeast, and West Shallow Soil PCB Plumes. AECOM Technical Services, Inc., personnel collected 330 soil samples from 118 boring locations. The samples were collected at 0.5-foot depth intervals to various depths based on analytical results and depth to groundwater. The soil samples were submitted to a fixed-based laboratory for analysis by United States Environmental Protection Agency Method 8082A for total PCBs. Several soil samples had PCB concentrations above the State of Florida Direct Exposure Residential and Industrial Soil Cleanup Target Levels (SCTLs), and two soil samples had PCB concentrations above the State of Florida Leachability for Groundwater. No soil borings were located beneath impervious surfaces, such as concrete or asphalt. The current Land Use Control Implementation Plan (LUCIP) covers PCBs in soils above the residential SCTL, which includes the paved areas.

PCBs↗

SUBSLAB SOIL GAS SAMPLING PLAN FOR COMMUNICATION, MAINTENANCE, AND STORAGE, SOLID WASTE MANAGEMENT UNIT (SWMU) 082

HydroGeoLogic, Inc. (HGL) prepared this Subslab Soil Gas (SSSG) Sampling Plan for Communications, Maintenance, and Storage (CM&S), Solid Waste Management Unit (SWMU) 082 for the National Aeronautics and Space Administration (NASA), Kennedy Space Center (KSC), Florida, under Contract Number 80KSC019D0012, Task Order 80KSC021F0097 technical directive #1, awarded on September 26, 2022. As described herein, all SSSG sampling and evaluations will be completed in accordance with U.S. Environmental Protection Agency’s (EPA), OSWER Technical Guide for Assessing and Mitigating the Vapor Intrusion Pathway from Subsurface Vapor Sources to Indoor Air (EPA, 2015).

Jason J Bublitz↗

Interim Measure Report South Water Pump Station Potential Release Location 213 – Location of Concern 2 Kennedy Space Center, Florida

This report presents a summary of the polychlorinated biphenyl (PCB) interim measure (IM) activities that occurred in December 2022 and March 2023 at Location of Concern (LOC) 2 – Electrical Equipment Area associated with the South Water Pump Station (SWPS) Potential Release Location (PRL) 213, located at the John F. Kennedy Space Center (KSC), Florida. The SWPS site is monitored under KSC’s Resource Conservation and Recovery Act Corrective Action Program, which also meets the requirements of Chapter 62-780, Florida Administrative Code. Assessment activities have previously been performed at six SWPS LOCs identified during a Solid Waste Management Unit assessment in 2013. Based on the data collected during these assessments, it was determined that IM activities would be completed at one of the LOCs, LOC 2 – Electrical Equipment Area, and an IM Work Plan was prepared and approved. In 2019, demolition of the SWPS buildings and structures was completed, allowing for additional assessment at LOC 2, and it was determined that soil excavation to remove PCB-impacted soils was no longer required for LOC 2. The IM activities conducted following demolition are presented in this report and include shallow soil sample collection, conducted in December 2022, and monitoring well installation and groundwater sampling, both conducted in March 2023. AECOM Technical Services, Inc. (AECOM) personnel collected two soil samples from two boring locations, SWPS-SB0005 and SWPS-SB0018. The samples were collected at 0 to 0.5 feet below land surface (bls). AECOM also conducted oversight of one monitoring well installation, SWPS-MW0001 screened from 4 to 14 feet bls, and then subsequently collected one groundwater sample from SWPS-MW0001. The samples were submitted to a fixed-based laboratory for analysis by United States Environmental Protection Agency Method 8082A for total PCBs. There were no detections of PCBs in soil or groundwater during the reporting period.

Chadwick Sloan Lee↗

Soil Interim Measures Implementation Report Q6 Radar Station – Solid Waste Management Unit 112 Locations of Concern 3 and 10 Kennedy Space Center, Florida

This report presents a summary of the soil interim measures (IM) implementation activities that occurred from January 23 through June 6, 2023, at the Q6 Radar Station (Q6RS) Solid Waste Management Unit (SWMU) 112, located at the John F. Kennedy Space Center (KSC), Florida. The site is monitored under KSC’s Resource Conservation and Recovery Act Corrective Action Program, which also meets the requirements of Chapter 62-780, Florida Administrative Code. Assessment activities have previously been performed at 10 Q6RS Locations of Concern (LOCs), identified during a SWMU assessment in 2013 (NASA 2013). Since the SWMU assessment, further confirmatory sampling and assessment was conducted for each LOC, and based on the data collected during these assessments, it was determined that Resource Conservation and Recovery Act Facility Investigation to further evaluate soil and groundwater was to be conducted at two LOCs: LOC 1 – Former Underground Storage Tanks (groundwater) and LOC 3 – Radar Antenna Refurbishment Area (soil). The LOC 1 groundwater assessment is ongoing, and the results will be presented under a separate cover. It was also determined that soil IM would be completed at two of the LOCs, LOC 3 and LOC 10 – Compressor Building Condensate Discharge. A Soil IM Work Plan was prepared and submitted in October 2021 (NASA 2021). The plan proposed excavation and disposal of barium and copper impacted soil in the LOC 3 and 10 areas. This report presents a summary and results of the soil IM implementation activities conducted at LOCs 3 and 10. The site contaminates of concern for this soil IM are barium and copper. The activities presented in this report includes soil IM implementation and groundwater sampling. From January 23 through March 24, 2023, AECOM Technical Services, Inc. (AECOM) field personnel conducted IM implementation activities in the LOC 3 and 10 areas. As presented in the IM Work Plan, shallow soils, impacted with metals, were excavated to a depth of 2 feet below land surface in the central area of the site around the radar antenna and associated equipment. AECOM personnel excavated 77.43 tons of soil using hand tools and, when able, heavy equipment. The soils were placed into lined roll-off containers, which were covered and transported under manifest to the Cedar Trail Landfill in Bartow, Florida. The site was restored to original condition using certified clean backfill material (sand), with filter fabric, and gravel. Areas outside of the excavation were restored with grass seed. On June 6, 2023, AECOM field personnel conducted groundwater sampling activities within the soil IM excavation area. AECOM personnel collected one groundwater sample from monitoring well Q6RS-MW0003. The sample was submitted to a fixed-based laboratory for analysis by United States Environmental Protection Agency Method 6020B for metals (barium and copper). Barium and copper were detected at 18 micrograms per liter (µg/L) and 14 µg/L, respectively, and were below the State of Florida Groundwater Cleanup Target Levels (GCTLs) for barium at 2,000 µg/L and copper at 1,000 µg/L.

Chadwick Sloan Lee↗

Launch Complex 34 SWMU CC054 Hot Spot Area 6 Expansion - Phase Three Implementation Work Plan

This Hot Spot (HS) Area 6 Air Sparge Expansion – Phase Three Implementation Work Plan (IWP) was prepared by Tetra Tech, Inc., for the National Aeronautics and Space Administration (NASA) under the Indefinite Delivery Indefinite Quantity Contract 80KSC019D0011-80KSC019F0067, for the implementation of an Air Sparging (AS) Interim Measure (IM) at Launch Complex 34 (LC34), located at Cape Canaveral Space Force Station (CCSFS), Florida. LC34 has been designated as Solid Waste Management Unit (SWMU) CC054 under the Kennedy Space Center (KSC) Resource Conservation and Recovery Act (RCRA) operating permit. Expansion of the HS 6 IM will include installation of an additional 192 AS wells to depths of approximately 40 feet below land surface (bls) to remediate contaminated groundwater within two areas located west and northeast of the existing HS 6 AS treatment area. These areas were delineated via direct push technology investigations in September and October 2023. The expansion will target “hot spot” concentrations of cis-1,2-dichloroethene (cDCE) and vinyl chloride (VC), which are the contaminants of concern in these areas with concentrations greater than 10-times Florida Department of Environmental Protection Natural Attenuation Default Concentrations. The highest cDCE and VC concentrations detected in the proposed phase three expansion area were 58,000 micrograms per liter (μg/L) (32 to 36 feet bls) and 12,000 μg/L (23 to 27 feet bls), respectively. The objective for this expansion is to remediate contaminated groundwater within the treatment zone to support transition to long-term monitoring. This phase three expansion will add an additional 9.4 acres of treatment area to the HS 6 IM, which currently covers approximately 26.9 acres.

Launch Complex 34↗

Validation Testing and Statistical Analysis of the Rotary Tumbler Fabric Abrasion Method

The Artemis space suit glove environmental protection garment (EPG) will be the first line of protection used to shield the crewmember’s hands from the environments encountered during extravehicular activity (EVA). As the Artemis missions will include more extreme environments than those experienced on the International Space Station, development, verification, and validation of gloves requires the development of new test methods. A previous paper focused on the development of a test procedure to characterize lunar EVA glove fabrics using ASTM standardized test methods and the design and validation of a new standardized test procedure for comparing abrasion resistance between fabrics using a dust and rock filled rotary tumbler. Preliminary results of testing were presented in that paper. This paper reports on the validation testing and statistical analysis of the newly developed tumbler abrasion test method.

Robert J Jones↗

Converter/Compressor Building Solid Waste Management Unit (SWMU) #89 Monitoring Well 21 Area Interim Measure Work Plan

This Work Plan details the approach and design for the Interim Measure (IM) to remediate groundwater within the MW21 Area where VOC concentrations exceed Florida Department of Environmental Protection Natural Attenuation Default Concentrations. The IM includes in-situ bioremediation via injection of emulsified vegetable oil (EVO) and emulsified zero-valent iron (EZVI). The in-situ bioremediation technology consists of injecting an electron donor substrate into the subsurface to promote microbial breakdown of VOCs. The EVO injections for this IM are designed based on the use of Provectus ERD-CH4, which is a vegetable oil/carbon substrate mixture. The EZVI injections for this IM are designed based on the use of Provectus EZVI-CH4. The IM treatment layout consists of nine injection locations of EVO at approximately 10-foot radius of influence (ROI) and three injections locations of EZVI at approximately 6-foot ROI. The injection method will be direct push using a DPT rig. The overall injection depths range from 7 to 17 ft bls. The 7 ft bls top depth is designed to be 2 ft below the water table to prevent substrates from reaching the top of the water table. Injections are planned to be implemented using 2 ft intervals and will take place using a bottom-up approach to 2 ft below the water table. This work plan further describes the IM design, injection calculations, performance monitoring plan, and provides an injection layout. Revision 1 of this Work Plan includes quarterly performance sampling during Year 1 in accordance with F.A.C. 62-780. These changes are reflected in Section 7 and Table 2 of the Work Plan.

Mark J Jonnet↗

Land Use Control Implementation Plan

This Land Use Control Implementation Plan (LUCIP) has been prepared to inform current and potential future users of the Corrosion Atmospheric Exposure Facility (CAEF) of institutional controls that have been implemented at the site. 1 Although most areas at CAEF do not pose current unacceptable risks to human health or the environment, areas of arsenic-impacted soil exceeding the Florida Department of Environmental Protection (Florida DEP) residential soil cleanup target levels (SCTLs) have been identified. Institutional land use controls (LUCs) are necessary to prevent contact with surface and subsurface soils at the site. Controls will include periodic inspection, condition certification, and agency notification.

soil↗

Satellite-Assisted Particulate Matter (SAPM) for the Models, In situ, and Remote Sensing of Aerosols (MIRA) Working Group

Models, In situ, and Remote sensing of Aerosols (MIRA) is an international working group that provides a forum for collaborations amongst these three atmospheric aerosol communities. MIRA consists of a collection of interdisciplinary and independently funded Topic/Project groups with clear goals and generally characterized by requests for additional scientific data. The Satellite-Assisted Particulate Matter (SAPM) Topic group focuses on the study of fine particulate matter (PM2.5), as it is a major contributor to air pollution and negatively impacts human health. Our group aims to provide intercomparisons of various methods and techniques for estimating surface PM2.5 assisted by satellite remote sensors (passive and active), global aerosol models, and in situ aerosol measurements. The overall motivation of our work is to enhance PM2.5 coverage beyond in situ ground stations, which can be limited. In this presentation, we provide an overview of various PM2.5 estimation approaches by current SAPM team members, as each approach has its own strengths and limitations. One approach uses near-surface aerosol extinction retrievals from the spaceborne Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) and an assumed value of mass extinction efficiency to derive PM2.5 concentrations (Toth et al 2019). A study using this method found a promising agreement (R=0.60; slope=0.89) with U.S. Environmental Protection Agency (EPA) in situ PM2.5 measurements over the contiguous United States (CONUS) for a 12-year (2007-2018) period (Toth et al 2022). In a different approach combining spaceborne lidar and a model, the Cloud Aerosol Transport System (CATS) lidar and Goddard Earth Observing System (GEOS) model are blended in an ensemble variational assimilation scheme to retrieve aerosol extinction and convert speciated mass concentrations to total PM2.5. A recent study (Matus et al in prep.) found agreement within 2 μg/m3 over the CONUS on the 2016 annual mean when compared to EPA ground-based measurements. Another study explored trends in city aerosol optical depth (AOD) from a spaceborne passive remote sensor, Moderate Resolution Imaging Spectroradiometer (MODIS), and found that these trends agree well with trends in city surface PM2.5, which provides confidence in the use of city AOD for city PM2.5 trend studies (Vohra et al 2021). In a follow-on study, steep and significant trends (~2.5 to 7.8% a-1) in AOD are found for several South Asian cities (e.g., Bangalore and Hyderabad), suggesting rapid growth in PM2.5 (Vohra et al 2022). Also in this presentation, we report results on our current collective SAPM study of India, a country that exhibits high levels of PM2.5 pollution. We show the temporal (i.e., seasonal) and spatial variability of PM2.5 over India using the CALIOP and CATS+model approaches, comparisons between the estimated PM2.5 from the retrieval schemes, and validation with in situ PM2.5 ground-based observations from the Central Pollution Control Board in India. This region provides us with an excellent case study to test our PM2.5 retrievals in heavily polluted scenes and over a complex and varying topography. The SAPM Topic group actively seeks international participants/collaborators in our group, including those working with in situ aerosol measurements (e.g., ACTRIS). We are interested in aerosol datasets in order to either improve our PM2.5 estimates from various approaches (e.g., using in situ mass scattering/absorption coefficient and aerosol hygroscopic properties for various aerosol species) and/or validate the PM2.5 estimates (e.g., using in situ ground-based PM2.5 concentrations).

Travis D Toth↗

Hydrocarbon Burn Facility, SWMU 007 Per- and Polyfluoroalkyl Substances (PFAS) Assessment Report Addendum

This document discusses the Per-and Polyfluoroalkyl Substances (PFAS) assessment activities performed from May through August 2023 at the Hydrocarbon Burn Facility (HBF) located at Kennedy Space Center (KSC), Florida. HBF was used for firefighting training between 1966 and 1994. Aqueous film-forming foams (AFFFs) that contained PFAS were used as suppressants for fighting petroleum fuel fires during training. PFAS sampling was first completed at HBF in 2015. This PFAS Assessment Report Addendum (ARA) is a continuation of sampling efforts, with an overall objective to further delineate PFAS concentrations in groundwater to the pGCTLs and the United States Environmental Protection Agency (EPA) Tapwater Regional Screening Levels (RSLs) dated November 2023 and better understand groundwater to surface water interaction at the Site. The field activities presented in this PFAS ARA were conducted between May and August 2023 and included the collection of 132 direct push groundwater samples and the collection of five colocated surface water, sediment, and pore water samples from locations south/southeast of HBF in August 2023. Exceedances of the pGCTLs and Tapwater RSLs were observed in the direct push groundwater results; however, groundwater has been delineated to the pGCTLs. Exceedances of the Florida provisional Surface Water Screening Levels (pSWSLs) were observed in surface water and porewater, and concentrations of PFAS in these media confirm PFAS migration within surface channels to the south of the HBF site area. Maximum sediment concentrations, which correlate with the maximum surface water and porewater concentrations, demonstrate that PFAS impacted surface water is the source of sediment impacts. Overall, elevated concentrations of PFAS are centered on the HBF site area that trend north and south along the surface water filled swales and along the edge of Banana River. Based on analytical results, not all surface water features in this area exhibit evidence of transport. PFAS migration/transport appears to be more dominant in surface water features during the wet season. Discharges to the Banana River primarily occur where surface water facilitates transport. In contrast, groundwater transport is more effective during the dry season. During precipitation events in either the dry season or the wet season, there appears to be migration from the intermediate groundwater zone to the shallow zone into the surface water features. Additional sampling and data collection is recommended to support further refinement of PFAS groundwater delineation, a remedial alternative evaluation, and the fate and transport model.

Jennifer Buel↗

Hypergol Maintenance Facility North, SWMU 090, Year 3 Air Sparge System Performance Monitoring Report, Kennedy Space Center, Florida

This Performance Monitoring Report (PMR) presents Year 3 Air Sparge (AS) System operation, maintenance, and monitoring (OM&M) activities and performance monitoring results for the AS Interim Measure (IM) at the Hypergol Maintenance Facility North (HMFN) at Kennedy Space Center (KSC), Florida. HMFN has been designated Solid Waste Management Unit (SWMU) 090 under the KSC Resource Conservation and Recovery Act Corrective Action Program. The timeframe for activities included in this report extends from September 2022 to August 2023. The HMFN AS IM was implemented in 2019-2020 to treat a chlorinated solvent groundwater plume that resulted from historical operations supporting the National Aeronautics and Space Administration (NASA) Space Program. The system includes 213 AS wells, with screen depths ranging from 25 feet to 45 feet below land surface (bls) and treats approximately 1.62 acres of contaminated groundwater. The objective of the AS IM is to actively reduce groundwater concentrations exceeding Florida Department of Environmental Protection Natural Attenuation Default Concentrations (NADCs) (identified as the High Concentration Plume [HCP]) to levels that facilitate transition into a Long-Term Monitoring program. The AS IM targets all of the HCP, except for a source zone area within the HCP where trichloroethene (TCE) concentrations exceed 11,000 micrograms per liter (μg/L) at depths greater than 45 feet bls. This is because site lithology was found to not be conducive to the AS treatment technology at these deeper depths. NASA will re-visit plans for potentially utilizing another remedial technology for residual deeper contamination following completion of the AS IM. OM&M activities and results from Year 3 indicate that the AS system at HMFN is operating as designed and is meeting performance criteria. Groundwater performance monitoring results indicate that following the third year of AS system operation, TCE concentrations in wells across all treated depth intervals have been reduced by an average of more than 99 percent. Overall, the areal extent of the plume showed a reduction following Year 3 of AS operations; however, continued operation of the AS system is required to meet the IM objective.

VOCs↗