Search NASA⌕ Search

SEARCH · Search NASA

Results for “Equivalent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Single-field consistency relations of large scale structure part III: test of the equivalence principle

The recently derived consistency relations for Large Scale Structure do not hold if the Equivalence Principle (EP) is violated. We show it explicitly in a toy model with two fluids, one of which is coupled to a fifth force. We explore the constraints that galaxy surveys can set on EP violation looking at the squeezed limit of the 3-point function involving two populations of objects. We find that one can explore EP violations of order 10{sup −3}÷10{sup −4} on cosmological scales. Chameleon models are already very constrained by the requirement of screening within the Solar System and only a very tiny region of the parameter space can be explored with this method. We show that no violation of the consistency relations is expected in Galileon models.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark energy and equivalence principle constraints from astrophysical tests of the stability of the fine-structure constant

Astrophysical tests of the stability of fundamental couplings, such as the fine-structure constant α, are becoming an increasingly powerful probe of new physics. Here we discuss how these measurements, combined with local atomic clock tests and Type Ia supernova and Hubble parameter data, constrain the simplest class of dynamical dark energy models where the same degree of freedom is assumed to provide both the dark energy and (through a dimensionless coupling, ζ, to the electromagnetic sector) the α variation. Specifically, current data tightly constrains a combination of ζ and the present dark energy equation of state w{sub 0}. Moreover, in these models the new degree of freedom inevitably couples to nucleons (through the α dependence of their masses) and leads to violations of the Weak Equivalence Principle. We obtain indirect bounds on the Eötvös parameter η that are typically stronger than the current direct ones. We discuss the model-dependence of our results and briefly comment on how the forthcoming generation of high-resolution ultra-stable spectrographs will enable significantly tighter constraints.

79 ASTRONOMY AND ASTROPHYSICS↗

Limits on the neutrino velocity, Lorentz invariance, and the weak equivalence principle with TeV neutrinos from gamma-ray bursts

Five TeV neutrino events weakly correlated with five gamma-ray bursts (GRBs) were detected recently by IceCube. This work is an attempt to show that if the GRB identifications are verified, the observed time delays between the TeV neutrinos and gamma-ray photons from GRBs provide attractive candidates for testing fundamental physics with high accuracy. Based on the assumed associations between the TeV neutrinos and GRBs, we find that the limiting velocity of the neutrinos is equal to that of photons to an accuracy of ∼ 1.9 × 10{sup -15} – 2.5 × 10{sup -18}, which is about 10{sup 4} – 10{sup 7} times better than the constraint obtained with the neutrino possibly from a blazar flare. In addition, we set the most stringent limits up to date on the energy scale of quantum gravity for both the linear and quadratic violations of Lorentz invariance, namely E {sub QG,} {sub 1} > 6.3 × 10{sup 18} – 1.5 × 10{sup 21} GeV and E {sub QG,} {sub 2} > 2.0 × 10{sup 11} – 4.2 × 10{sup 12} GeV, which are essentially as good as or are an improvement of one order of magnitude over the results previously obtained by the GeV photons of GRB 090510 and the PeV neutrino from a blazar flare. Assuming that the Shapiro time delay is caused by the gravitational potential of the Laniakea supercluster of galaxies, we also place the tightest limits to date on Einstein's weak equivalence principle through the relative differential variations of the parameterized post-Newtonian parameter γ values for two different species of particles (i.e., neutrinos and photons), yielding Δγ ∼ 10{sup -11} – 10{sup -13}. However, it should be emphasized again that these limits here obtained are at best forecast of what could be achieved if the GRB/neutrino correlations would be finally confirmed.

79 ASTRONOMY AND ASTROPHYSICS↗

GALACTIC-CENTER S STARS AS A PROSPECTIVE TEST OF THE EINSTEIN EQUIVALENCE PRINCIPLE

The S stars in the Galactic-center region are found to be on near-perfect Keplerian orbits around presumably a supermassive black hole, with periods of 15-50 yr. Since these stars reach a few percent of light speed at pericenter, various relativistic effects are expected and have been discussed in the literature. We argue that an elegant test of the Einstein equivalence principle should be possible with existing instruments, through spectroscopic monitoring of an S star concentrated during the months around pericenter, supplemented with an already-adequate astrometric determination of the inclination. In essence, the spectrum of an S star can be considered a heterogeneous ensemble of clocks in a freely falling frame, which near pericenter is moving at relativistic speeds.

79 ASTRONOMY AND ASTROPHYSICS↗

Bond Wire Damage Detection and State of Health Estimation of a 1200V, 900A Dual Pack IGBT Power Module using the RL-Equivalent Circuit

Electrical and environmental stresses are the two dominant contributors in aging and failure of power semiconductor devices. Insulated gate bipolar junction transistors (IGBTs) and metal-oxide semiconductor field effect transistors (MOSFETs) are two most commonly used switching devices in power converter circuits. A significant portion of research effort is given in inventing innovative methods to estimate the degradation and fatigue in these devices. Until today, no other existing techniques can determine the number of lifted bond wires and their locations in a live IGBT module, although this information is extremely helpful to understand the overall state of health of an IGBT power module. In this paper, we have proposed a reflectometry-based technique to overcome this hurdle. The RL-equivalent circuit to represent a bond wire has been developed for the device under test and simulated in CST Studio Suite to measure the reflection amplitudes. Experimental results were obtained using a prototype reflectometry hardware, and both the simulation and experimental results have been compared. These results prove that with these two sets of measurements, it is possible to locate the aged device inside a module and detect the number of bond wire lift-offs associated to that device.

30 DIRECT ENERGY CONVERSION↗

Evaluation of Equivalent Battery Model Representations for Thermostatically Controlled Loads in Commercial Buildings

Models for thermostatically controlled loads in commercial buildings often include many parameters and variables compared to residential buildings. As such, it is beneficial to use reduced-order models to represent these resources. A classic example of such a model is the Virtual Battery or Equivalent Battery Model (EBM). In this paper, the typical EBM is extended to higher-order commercial Heating, Ventilation, and Air-conditioning (HVAC) models and adapted for electric water heaters. Finally, we compare the performance of EBMs with detailed thermal models using three classic optimization problems - energy maximization, energy minimization, and power reference tracking. Our results show that the EBM-constrained and detailed thermal model-constrained problems produce similar outcomes in terms of temperature, power, and total energy consumption.

commercial buildings↗

Large-signal Stability Analysis of Grid-forming Inverters with Equivalent-circuit Models

Here, this paper proposes an energy function-based direct method for large-signal stability assessment of grid-forming (GFM) inverters leveraging an equivalent-circuit representation of all involved control- and physical-layer dynamics. Three different primary controls, a standard inner-current outer-voltage cascaded-control architecture, output LCL filter, and reference-current saturation limiting are featured in the modeling and analysis framework. A composite energy function for the GFM inverter is obtained by summing up individual energy contributions gleaned from the circuit representation. The approach can readily be generalized to different primary controls, output-filter arrangements, and current limiters since it is based on a circuit-theoretic foundation. Numerical simulations validate the efficacy of the approach in estimating the critical clearing time following a large-signal disturbance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Equivalent-circuit model for vacuum ultraviolet irradiation of dielectric films

Vacuum ultraviolet (VUV) irradiation, which occurs during plasma processing, causes photoemission of electrons from the dielectrics. Photoemission primarily occurs from defect states in the band gap of the dielectric and results in trapped positive charges. The trapped positive charges are negated by photoinjection of electrons from the underlying substrate into the dielectric. The authors propose an equivalent-circuit model using with which, once the circuit parameters are determined, charging of dielectric materials under VUV irradiation can be predicted. The circuit includes a dielectric capacitor, the intrinsic and photo conductivities of the dielectric and substrate, and the processes of photoemission and photoinjection.

36 MATERIALS SCIENCE↗

Biological equivalent dose studies for dose escalation in the stereotactic synchrotron radiation therapy clinical trials

Synchrotron radiation is an innovative tool for the treatment of brain tumors. In the stereotactic synchrotron radiation therapy (SSRT) technique a radiation dose enhancement specific to the tumor is obtained. The tumor is loaded with a high atomic number (Z) element and it is irradiated in stereotactic conditions from several entrance angles. The aim of this work was to assess dosimetric properties of the SSRT for preparing clinical trials at the European Synchrotron Radiation Facility (ESRF). To estimate the possible risks, the doses received by the tumor and healthy tissues in the future clinical conditions have been calculated by using Monte Carlo simulations (PENELOPE code). The dose enhancement factors have been determined for different iodine concentrations in the tumor, several tumor positions, tumor sizes, and different beam sizes. A scheme for the dose escalation in the various phases of the clinical trials has been proposed. The biological equivalent doses and the normalized total doses received by the skull have been calculated in order to assure that the tolerance values are not reached.

61 RADIATION PROTECTION AND DOSIMETRY↗

Theoretical and empirical investigations of KCl:Eu{sup 2+} for nearly water-equivalent radiotherapy dosimetry

Purpose: The low effective atomic number, reusability, and other computed radiography-related advantages make europium doped potassium chloride (KCl:Eu{sup 2+}) a promising dosimetry material. The purpose of this study is to model KCl:Eu{sup 2+} point dosimeters with a Monte Carlo (MC) method and, using this model, to investigate the dose responses of two-dimensional (2D) KCl:Eu{sup 2+} storage phosphor films (SPFs). Methods: KCl:Eu{sup 2+} point dosimeters were irradiated using a 6 MV beam at four depths (5-20 cm) for each of five square field sizes (5x5-25x25 cm{sup 2}). The dose measured by KCl:Eu{sup 2+} was compared to that measured by an ionization chamber to obtain the magnitude of energy dependent dose measurement artifact. The measurements were simulated using DOSXYZnrc with phase space files generated by BEAMnrcMP. Simulations were also performed for KCl:Eu{sup 2+} films with thicknesses ranging from 1 {mu}m to 1 mm. The work function of the prototype KCl:Eu{sup 2+} material was determined by comparing the sensitivity of a 150 {mu}m thick KCl:Eu{sup 2+} film to a commercial BaFBr{sub 0.85}I{sub 0.15}:Eu{sup 2+}-based SPF with a known work function. The work function was then used to estimate the sensitivity of a 1 {mu}m thick KCl:Eu{sup 2+} film. Results: The simulated dose responses of prototype KCl:Eu{sup 2+} point dosimeters agree well with measurement data acquired by irradiating the dosimeters in the 6 MV beam with varying field size and depth. Furthermore, simulations with films demonstrate that an ultrathin KCl:Eu{sup 2+} film with thickness of the order of 1 {mu}m would have nearly water-equivalent dose response. The simulation results can be understood using classic cavity theories. Finally, preliminary experiments and theoretical calculations show that ultrathin KCl:Eu{sup 2+} film could provide excellent signal in a 1 cGy dose-to-water irradiation. Conclusions: In conclusion, the authors demonstrate that KCl:Eu{sup 2+}-based dosimeters can be accurately modeled by a MC method and that 2D KCl:Eu{sup 2+} films of the order of 1 {mu}m thick would have minimal energy dependence. The data support the future research and development of a KCl:Eu{sup 2+} storage phosphor-based system for quantitative, high-resolution multidimensional radiation therapy dosimetry.

36 MATERIALS SCIENCE↗

SU-E-T-55: Biological Equivalent Dose (BED) Comparison Between Permanent Interstitial Brachytherapy and Conventional External Beam Radiotherapy for Prostate Cancer

Purpose: The goal of this research is to calculate and compare the Biological Equivalent Dose (BED) between permanent prostate Iodine-125 implant brachytherapy as monotherapy with the BED of conventional external beam radiation therapy (EBRT). Methods: A retrospective study of 605 patients treated with Iodine-125 seed implant was performed in which physician A treated 274 patients and physician B treated 331 patients. All the Brachytherapy treatment plans were created using VariSeed 8 planning system. The Iodine-125 seed source activities and loading patterns varied slightly between the two physicians. The prescription dose is 145 Gy to PTV for each patient. The BED and Tumor Control Probability (TCP) were calculated based on the TG 137 formulas. The BED for conventional EBRT of the prostate given in our institution in 2Gy per fraction for 38 fractions was calculated and compared. Results: Physician A treated 274 patients with an average BED of 123.92±0.87 Gy and an average TCP of 99.20%; Physician B treated 331 patients with an average BED of 124.87±1.12 Gy and an average TCP of 99.30%. There are no statistically significant differences (T-Test) between the BED and TCP values calculated for these two group patients.The BED of the patients undergoing conventional EBRT is calculated to be 126.92Gy. The BED of the patients treated with permanent implant brachytherapy and EBRT are comparable. Our BED and TCP values are higher than the reported values by TG 137 due to higher Iodine-125 seed activity used in our institution. Conclusion: We calculated the BED,a surrogate of the biological response to a permanent prostate brachytherapy using TG 137 formulas and recommendation. The TCP of better than 99% is calculated for these patients. A clinical outcome study of these patients correlating the BED and TCP values with PSA and Gleason Levels as well as patient survival is warranted.

60 APPLIED LIFE SCIENCES↗

SU-E-T-365: Estimation of Neutron Ambient Dose Equivalents for Radioprotection Exposed Workers in Radiotherapy Facilities Based On Characterization Patient Risk Estimation

Purpose: Previous measurements with Bonner spheres{sup 1} showed that normalized neutron spectra are equal for the majority of the existing linacs{sup 2}. This information, in addition to thermal neutron fluences obtained in the characterization procedure{sup 3}3, would allow to estimate neutron doses accidentally received by exposed workers, without the need of an extra experimental measurement. Methods: Monte Carlo (MC) simulations demonstrated that the thermal neutron fluence distribution inside the bunker is quite uniform, as a consequence of multiple scatter in the walls{sup 4}. Although inverse square law is approximately valid for the fast component, a more precise calculation could be obtained with a generic fast fluence distribution map around the linac, from MC simulations{sup 4}. Thus, measurements of thermal neutron fluences performed during the characterization procedure{sup 3}, together with a generic unitary spectra{sup 2}, would allow to estimate the total neutron fluences and H*(10) at any point{sup 5}. As an example, we compared estimations with Bonner sphere measurements{sup 1}, for two points in five facilities: 3 Siemens (15–23 MV), Elekta (15 MV) and Varian (15 MV). Results: Thermal neutron fluences obtained from characterization, are within (0.2–1.6×10{sup 6}) cm−{sup 2}•Gy{sup −1} for the five studied facilities. This implies ambient equivalent doses ranging from (0.27–2.01) mSv/Gy 50 cm far from the isocenter and (0.03–0.26) mSv/Gy at detector location with an average deviation of ±12.1% respect to Bonner measurements. Conclusion: The good results obtained demonstrate that neutron fluence and H*(10) can be estimated based on: (a) characterization procedure established for patient risk estimation in each facility, (b) generic unitary neutron spectrum and (c) generic MC map distribution of the fast component. [1] Radiat. Meas (2010) 45: 1391 – 1397; [2] Phys. Med. Biol (2012) 5 7:6167–6191; [3] Med. Phys (2015) 42:276 - 281. [4] IFMBE (2012) 39: 1245–1248. [5] ICRU Report 57 (1998)

60 APPLIED LIFE SCIENCES↗

Radiotherapy for stage I seminoma of the testis: Organ equivalent dose to partially in-field structures and second cancer risk estimates on the basis of a mechanistic, bell-shaped, and plateau model

Purpose: The aim of the current study was to (a) calculate the organ equivalent dose (OED) and (b) estimate the associated second cancer risk to partially in-field critical structures from adjuvant radiotherapy for stage I seminoma of the testis on the basis of three different nonlinear risk models. Methods: Three-dimensional plans were created for twelve patients who underwent a treatment planning computed tomography of the abdomen. The plans for irradiation of seminoma consisted of para-aortic anteroposterior and posteroanterior fields giving 20 Gy to the target site with 6 MV photons. The OED of stomach, colon, liver, pancreas, and kidneys, that were partially included in the treatment volume, was calculated using differential dose–volume histograms. The mechanistic, bell-shaped, and plateau models were employed for these calculations provided that organ-specific parameters were available for the subsequent assessment of the excess absolute risk (EAR) for second cancer development. The estimated organ-specific lifetime risks were compared with the respective nominal intrinsic probabilities for cancer induction. Results: The mean OED, which was calculated from the patients’ treatment plans, varied from 0.54 to 6.61 Gy by the partially in-field organ of interest and the model used for dosimetric calculations. The difference between the OED of liver derived from the mechanistic model with those from the bell-shaped and plateau models was less than 1.8%. An even smaller deviation of 1.0% was observed for colon. For the rest organs of interest, the differences between the OED values obtained by the examined models varied from 8.6% to 50.0%. The EAR for stomach, colon, liver, pancreas, and kidney cancer induction at an age of 70 yr because of treatment of a typical 39-yr-old individual was up to 4.24, 11.39, 0.91, 3.04, and 0.14 per 10 000 persons-yr, respectively. Patient’s irradiation was found to elevate the lifetime intrinsic risks by 8.3%–63.0% depending upon the organ of interest and the model employed for risk analysis. Conclusions: Radiotherapy for stage I seminoma of the testis may result in an excess risk for the appearance of secondary malignancies in partially in-field organs. The organ- and model-dependent second cancer risk assessments of this study may be of value for patient counseling and follow-up.

60 APPLIED LIFE SCIENCES↗

SU-F-T-124: Radiation Biological Equivalent Presentations OfLEM-1 and MKM Approaches in the Carbon-Ion Radiotherapy

Purpose: To study the correlations of the radiation biological equivalent doses (BED) along depth and lateral distance between LEM-1 and MKM approaches. Methods: In NIRS-MKM (Microdosimetric Kinetic Model) approach, the prescribed BED, referred as C-Eq, doses aims to present the relative biological effectiveness (RBE) for different energies of carbon-ions on a fixed 10% survival value of HCG cell with respect to convention X-ray. Instead of a fixed 10% survival, the BED doses of LEM-1 (Local Effect Model) approach, referred as X-Eq, aims to present the RBE over the whole survival curve of chordoma-like cell with alpha/beta ratio of 2.0. The relationship of physical doses as a function of C-Eq and X-Eq doses were investigated along depth and lateral distance for various sizes of cubic targets in water irradiated by carbon-ions. Results: At the center of each cubic target, the trends between physical and C-Eq or X-Eq doses can be described by a linear and 2nd order polynomial functions, respectively. Using fit functions can then calculate a scaling factor between C-Eq and X-Eq doses to have similar physical doses. With equalized C-Eq and X-Eq doses at the depth of target center, over- and under-estimated X-Eq to C-Eq are seen for depths before and after the target center, respectively. Near the distal edge along depth, sharp rising of RBE value is observed for X-Eq, but sharp dropping of RBE value is observed for C-Eq. For lateral locations near and just outside 50% dose level, sharp raising of RBE value is also seen for X-Eq, while only minor increasing with fast dropping for C-Eq. Conclusion: An analytical function to model the differences between the CEq and X-Eq doses along depth and lateral distance need to further investigated to explain varied clinic outcome of specific cancers using two different approaches to calculated BED doses.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

SU-F-T-655: Evaluation of Neutron Dose Equivalent Inside of Treatment Vault of Radiotherapy by Photoneutron Production in the Primary Barriers

Purpose: Photon beams with energy higher than 10 MV interact with metal material in the primary barriers, where lead or steel have been widely used, neutrons can be generated. Monte Carlo simulations were performed to simulate the production of photoneutrons and the neutron shielding effect. Methods: For two photon beam energies, 15 MV and 18 MV, we simulated to strike metal sheets (steel and lead), and the ambient dose equivalents were calculated at the isocenter (in the patient plane) while delivering 1 Gy to the patient. For these cases, the thickness of the neutron shielding materials (Borated polyethylene (BPE) and concrete) were simulated to reduce the patient exposure by neutron doses. Results: When 18 MV photons interact with the metal sheets in the primary barrier, the evaluated neutron doses at the isocenter inside the treatment vault were 48.7 µSv and 7.3 µSv for lead and steel, respectively. In case of 15 MV photons, the calculated neutron doses were 18.6 µSv and 0.6 µSv for lead and steel, respectively. The neutron dose delivered to the patient can be reduced to negligible levels by including a 10 cm thick sheet of BPE or 22 cm thick sheet of concrete. Conclusion: When bunker shielding is designed with a primary barrier including a metal sheet inside the wall for a high energy machine, proper neutron shielding should be constructed to avoid undesirable extra dose.

60 APPLIED LIFE SCIENCES↗

Machine Learning Benchmarks for the Classification of Equivalent Circuit Models from Electrochemical Impedance Spectra

Analysis of Electrochemical Impedance Spectroscopy (EIS) data for electrochemical systems often consists of defining an Equivalent Circuit Model (ECM) using expert knowledge and then optimizing the model parameters to deconvolute various resistance, capacitive, inductive, or diffusion responses. For small data sets, this procedure can be conducted manually; however, it is not feasible to manually define a proper ECM for extensive data sets with a wide range of EIS responses. Automatic identification of an ECM would substantially accelerate the analysis of large sets of EIS data. We showcase machine learning methods to classify the ECMs of 9,300 impedance spectra provided by QuantumScape for the BatteryDEV hackathon. The best-performing approach is a gradient-boosted tree model utilizing a library to automatically generate features, followed by a random forest model using the raw spectral data. A convolutional neural network using boolean images of Nyquist representations is presented as an alternative, although it achieves a lower accuracy. We publish the data and open source the associated code. The approaches described in this article can serve as benchmarks for further studies. A key remaining challenge is the identifiability of the labels, underlined by the model performances and the comparison of misclassified spectra.

25 ENERGY STORAGE↗

Modeling Spatial Distribution of Snow Water Equivalent by Combining Meteorological and Satellite Data with Lidar Maps

Abstract An accurate characterization of the water content of snowpack, or snow water equivalent (SWE), is necessary to quantify water availability and constrain hydrologic and land surface models. Recently, airborne observations (e.g., lidar) have emerged as a promising method to accurately quantify SWE at high resolutions (scales of ∼100 m and finer). However, the frequency of these observations is very low, typically once or twice per season in the Rocky Mountains of Colorado. Here, we present a machine learning framework that is based on random forests to model temporally sparse lidar-derived SWE, enabling estimation of SWE at unmapped time points. We approximated the physical processes governing snow accumulation and melt as well as snow characteristics by obtaining 15 different variables from gridded estimates of precipitation, temperature, surface reflectance, elevation, and canopy. Results showed that, in the Rocky Mountains of Colorado, our framework is capable of modeling SWE with a higher accuracy when compared with estimates generated by the Snow Data Assimilation System (SNODAS). The mean value of the coefficient of determination R 2 using our approach was 0.57, and the root-mean-square error (RMSE) was 13 cm, which was a significant improvement over SNODAS (mean R 2 = 0.13; RMSE = 20 cm). We explored the relative importance of the input variables and observed that, at the spatial resolution of 800 m, meteorological variables are more important drivers of predictive accuracy than surface variables that characterize the properties of snow on the ground. This research provides a framework to expand the applicability of lidar-derived SWE to unmapped time points. Significance Statement Snowpack is the main source of freshwater for close to 2 billion people globally and needs to be estimated accurately. Mountainous snowpack is highly variable and is challenging to quantify. Recently, lidar technology has been employed to observe snow in great detail, but it is costly and can only be used sparingly. To counter that, we use machine learning to estimate snowpack when lidar data are not available. We approximate the processes that govern snowpack by incorporating meteorological and satellite data. We found that variables associated with precipitation and temperature have more predictive power than variables that characterize snowpack properties. Our work helps to improve snowpack estimation, which is critical for sustainable management of water resources.

54 ENVIRONMENTAL SCIENCES↗

Model estimates of dissolved organic carbon, runoff, snowmelt, and snow water equivalent from 1981-2010 across the western Arctic

This dataset contains estimates of dissolved organic carbon (DOC) yield (mg C m-2), runoff (mm day-1), snow water equivalent (SWE, mm day-1), and snowmelt (mm day-1) from a simulation of the Permafrost Water Balance Model (PWBM v4). The simulation effectively quantifies snowpack accumulation and melt, runoff, and DOC leaching, and broadly capture the seasonal cycle in DOC concentration and mass loadings. Daily air temperature, precipitation, and wind speed data from the Modern-Era Retrospective Analysis for Research and Applications (MERRA) were used for meteorological forcings. The model outputs are organized by grid and day of the month in gzipped ASCII text files contained within each archived ZIP file. No special software is required to work with these data. The basin and domain information files are also ASCII text. The gridded estimates are most useful for analyses of the spatial and temporal variations in terrestrial hydrology and leachate DOC concentrations and loadings across parts of the western Arctic. A manuscript describing the data and associated analysis has been accepted for publication in Journal of Geophysical Research - Biogeosciences (Rawlins et al., 2021).

54 ENVIRONMENTAL SCIENCES↗