Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

An assessment of thermodynamic merits for current and potential future engine operating strategies

The present work compares the fundamental thermodynamic underpinnings (i.e., working fluid properties and heat release profile) of various combustion strategies with engine measurements. The approach employs a model that separately tracks the impacts on efficiency due to differences in rate of heat addition, volume change, mass addition, and molecular weight change for a given combination of working fluid, heat release profile, and engine geometry. Comparative analysis between measured and modeled efficiencies illustrates fundamental sources of efficiency reductions or opportunities inherent to various combustion regimes. Engine operating regimes chosen for analysis include stoichiometric spark-ignited combustion and lean compression-ignited combustion including HCCI, SA-HCCI, RCCI, GCI, and CDC. Within each combustion regime, effects such as engine load, combustion duration, combustion phasing, combustion chamber geometry, fuel properties, and charge dilution are explored. Model findings illustrate that even in the absence of losses such as heat transfer or incomplete combustion, the maximum possible thermal efficiency inherent to each operating strategy varies to a significant degree. Additionally, the experimentally measured losses are observed to be unique within a given operating strategy. The findings highlight the fact that in order to create a roadmap for future directions in ICE technologies, it is important to not only compare the absolute real-world efficiency of a given combustion strategy, but to also examine the measured efficiency in context of what is thermodynamically possible with the working fluid and boundary conditions prescribed by a strategy.

33 ADVANCED PROPULSION SYSTEMS↗

Compositions, antibodies, asthma diagnosis methods, and methods for preparing antibodies

Methods for preparing an antibody are provided with the method including incorporating 3-bromo-4-hydroxy-benzoic acid into a protein to form an antigen, immunizing a mammalian host with the antigen, and recovering an antibody having an affinity for the antigen from the host. Antibodies having a binding affinity for a monohalotyrosine are provided as well as composition comprising an antibody bound with monohalotyrosine. Compositions comprising a protein having a 3-bromo-4-hydroxy-benzoic acid moiety are also provided. Methods for evaluating the severity of asthma are provide with the methods including analyzing sputum of a patient using an antibody having a binding affinity for monohalotyrosine, and measuring the amount of antibody bound to protein. Methods for determining eosinophil activity in bodily fluid are also provided with the methods including exposing bodily fluid to an antibody having a binding affinity for monohalotyrosine, and measuring the amount of bound antibody to determine the eosinophil activity.

59 BASIC BIOLOGICAL SCIENCES↗

A first principles method to determine speciation of carbonates in supercritical water

The determination of the speciation of ions and molecules in supercritical aqueous fluids under pressure is critical to understanding their mass transport in the Earth's interior. Unfortunately, there is no experimental technique yet available to directly characterize species dissolved in water at extreme conditions. Here we present a strategy, based on first-principles simulations, to determine ratios of Raman scattering cross-sections of aqueous species under extreme conditions, thus providing a key quantity that can be used, in conjunction with Raman measurements, to predict chemical speciation in aqueous fluids. Due to the importance of the Earth's carbon cycle, we focus on carbonate and bicarbonate ions. Our calculations up to 11 GPa and 1000 K indicate a higher concentration of bicarbonates in water than previously considered at conditions relevant to the Earth's upper mantle, with important implications for the transport of carbon in aqueous fluids in the Earth's interior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A high-pressure atomic force microscope for imaging in supercritical carbon dioxide

A high-pressure atomic force microscope (AFM) that enables in-situ, atomic scale measurements of topography of solid surfaces in contact with supercritical CO2 (scCO2) fluids has been developed. This apparatus overcomes the pressure limitations of the hydrothermal AFM and is designed to handle pressures up to 100 atm at temperatures up to ~ 350 K. A standard optically-based cantilever deflection detection system was chosen. When imaging in compressible supercritical fluids such as scCO2, precise control of pressure and temperature in the fluid cell is the primary technical challenge. Noise levels and imaging resolution depend on minimization of fluid density fluctuations that change the fluid refractive index and hence the laser path. We demonstrate with our apparatus in-situ atomic scale imaging of a calcite (CaCO3) mineral surface in scCO2; both single, monatomic steps and dynamic processes occurring on the (10¯14) surface are presented. This new AFM provides unprecedented in-situ access to interfacial phenomena at solid-fluid interfaces under pressure.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MASS TRANSFER COEFFICIENTS FOR A NON-NEWTONIAN FLUID AND WATER WITH AND WITHOUT ANTI-FOAM AGENTS

Mass transfer rates were measured in a large scale system, which consisted of an 8.4 meter tall by 0.76 meter diameter column containing one of three fluids: water with an anti-foam agent, water without an anti-foam agent, and AZ101 simulant, which simulated a non-Newtonian nuclear waste. The testing contributed to the evaluation of large scale mass transfer of hydrogen in nuclear waste tanks. Due to its radioactivity, the waste was chemically simulated, and due to flammability concerns oxygen was used in lieu of hydrogen. Different liquids were used to better understand the mass transfer processes, where each of the fluids was saturated with oxygen, and the oxygen was then removed from solution as air bubbled up, or sparged, through the solution from the bottom of the column. Air sparging was supplied by a single tube which was co-axial to the column, the decrease in oxygen concentration was recorded, and oxygen measurements were then used to determine the mass transfer coefficients to describe the rate of oxygen transfer from solution. Superficial, average, sparging velocities of 2, 5, and 10 mm/second were applied to each of the liquids at three different column fill levels, and mass transfer coefficient test results are presented here for combinations of superficial velocities and fluid levels.

08 HYDROGEN↗

Experimental verification of the Boltzmann relation in confined plasmas: Comparison of noble and molecule gases

Experimental verification of the Boltzmann relation is performed in argon and oxygen gas inductively coupled plasmas from the measurements of both the spatial electron currents (as a fluid approach) and the electron energy probability functions (EEPFs, as a kinetic approach). At a low gas pressure of 10 mTorr, the measured electron currents are spatially uniform, and the EEPFs in the total electron energy scale are identical, which indicate that the Boltzmann relation is valid at both the argon and oxygen gases. As the gas pressure increases to 30-40 mTorr, however, the Boltzmann relation is broken in the oxygen gas discharge, while the Boltzmann relation is still valid in the argon gas discharge. This different variation in the oxygen gas discharge is mainly due to the presence of various inelastic collisions in the entire electron energy region, which causes the transition of the electron kinetics from a non-local to a local regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electric Motor Thermal Management for Electric Traction Drives (Presentation)

Thermal constraints place significant limitations on how electric motors ultimately perform. Finite element analysis and computational fluid dynamics modeling approaches are being increasingly utilized in the design and analysis of electric motors. As the models become more sophisticated, it is important to have detailed and accurate knowledge of material thermal properties and convective heat transfer coefficients. In this work, the thermal properties and inter-lamination thermal contact resistances were measured for different stator lamination materials. Also, convective heat transfer coefficients of automatic transmission fluid (ATF) jets were measured to better understand the heat transfer of ATF impinging on motor copper windings. Experiments were carried out at various ATF temperatures and jet velocities to quantify the influence of these parameters on heat transfer coefficients.

30 DIRECT ENERGY CONVERSION↗

Characterization of Intrinsic Fiber Optic Temperature Sensors by In-core and Furnace Testing

Increased research and development in nuclear technology has raised the demand for novel sensors and instrumentation to meet data objectives, and survive in different conditions and environments, beyond conventional light water reactor (LWR) environments. Expediting the deployment of advanced nuclear technologies by developing, demonstrating, and qualifying advanced reactor fuel forms necessitates a deeper understanding of how irradiation affects fuels and materials' performance. To achieve a more comprehensive understanding of fuels and materials performance, researchers require more specialized experiments and measurements. The demand for innovative sensors to support nuclear fuel development arises from the complexity of materials' behavior under irradiation and the challenges of deploying instrumentation in Material Test Reactors (MTRs) for irradiation tests. Additionally, measurements of material properties require integrated measurement systems to characterize thermal properties, mechanical properties, chemistry, and microstructure [1]. Among the potential measurement techniques, optical fiber-based sensors have been identified as potential sensors to measure different physical phenomena such as temperature, strain, pressure, and fluid level. Optical fiber sensors have the capability to provide multi-sensing and multiplexing instrumentation, allowing the measurement of different physical parameters within a single sensor configuration, and transmitting data collected at multiple locations through a single fiber. They offer immunity to electromagnetic interference, electrical passivity, compatibility with various sensing methodologies, and cost-effectiveness. Beyond their widespread use in telecommunications, silica fiber-based instruments are utilized in industrial applications, even at temperatures reaching 300?400°C, such as distributed temperature sensing in oil and gas recovery. The Department of Energy (DOE) is interested in using fiber optics to support fuel cycle development [2]. Fiber optics are an excellent candidate for harsh environment sensing, including sensing at very high temperatures (1900oC for sapphire optical fibers). Distributed fiber optic sensing has been deployed in other harsh environments like coal gasification plants [3]. Distributed strain sensing, which operates similarly to distributed temperature sensing, has been deployed to monitor underground mines and fibers have been imbedded in soil to monitor sink-hole development [4][5]. The application of fiber optic sensors to advanced reactor development is a promising area of research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic Frictional Characteristics of TP2 Copper Tubes during Hydroforming under Different Loading and Fluid Velocities

Tube hydroforming (THF) experiments were performed on TP2 copper tubes under different loading velocities and fluid velocities using a self-developed measurement system to investigate dynamic frictional characteristics in the guiding zone. The results show that the coefficient of friction (COF) dynamically changes during forming experiments and decreases with tube deformation. The average descending rate and amplitude of the COF increase with increasing loading velocity. Microscopically, the micro-protrusions on the tubular surface are flattened, and the surface scratches are finer and more uniform, as the loading velocity increases, resulting in a decrease in COF. At the same external loading velocity, the COF increases with increasing fluid velocity and is also extremely sensitive to it. Moreover, improving and predicting the formability of such tubes by accurately adjusting and controlling fluid velocity in THF is valuable and critical for the future.

36 MATERIALS SCIENCE↗

Calibration of NMR porosity to estimate permeability in carbonate reservoirs

Considering the performance of carbon dioxide (CO 2 ) stored in geologic reservoirs requires some knowledge of the subsurface heterogeneity, where the most reliable data is extracted from wellbore measurements. This benefit is especially true for carbonate reservoirs were reactions between supercritical CO 2 , the reservoir brine, and carbonate minerals create new storage capacity and enhanced permeability. Techniques like NMR well logging hold promise for estimating subsurface permeability, because the total porosity and pore size can be calculated from response of 1 H NMR signal. Resulting depth profiles of porosity and permeability from downhole logs are useful input for reservoir simulations and can be used to design injection protocols and estimate storage capacity. We conducted a detailed characterization study to quantify the NMR response to matrix pore space, the connectivity to larger vugs and fractures, and the resulting permeability of core samples from distinct carbonate formations. The cores used in study span 5 orders in permeability, 4 orders in mean T 2 , and 2%–42% in porosity. The goal of the study was to use independent measures of pore volumes, surface relaxivity, fluid-accessible surface areas, and permeability to develop carbonate permeability models. It was not possible to develop a single model that reproduced permeability for different carbonate formations, because phenomena specific to the reservoirs could not be extracted even with the state-of-the-art characterization techniques used in this study. Estimates of permeability require calibration. Best calculations for a given formation were achieved by using a simple form of the Kozeny equation (Eq. 6): κ=Α’θ 3*n , and calibrating A’ and n with laboratory measurements made on the formation cores. Empirical calibrations can then be used to map the vertical heterogeneity of the storage complex to better understand the physical movement CO 2 and brine in the subsurface and the positive feedback between mineral dissolution and the development of flow pathways.

54 ENVIRONMENTAL SCIENCES↗

Primary coolant flow measurement for integral pressurized water reactors using ultrasonic technique - 182

Several pressurized water reactor (PWR) systems under development employ integral primary coolant loop designs, where the primary coolant does not leave the reactor pressure vessel during operation (I{sup 2}S-LWR, mPower, NuScale). The absence of primary coolant piping inhibits traditional pressurized water reactor primary coolant flow measurement, in which the differential pressure across the steam generator is correlated to flow rate. To address this, a transit time, reflection mode, ultrasonic flow meter is proposed. An experimental flow loop utilizing a test section representative of a thin azimuthal slice of the down-comer region of an integral PWR has been constructed to test the efficacy of the General Electric AT600 ultrasonic flow meter (UFM) in such an application. A Great Plains Industries TM300 turbine flow meter (TFM), reporting volumetric flow rate and installed in-line with the flow loop piping, is used as the reference meter. UFM performance is affected by several factors, including flow development and symmetry. The UFM was installed on three locations along the flow path of water through the test section. The meter performed the best at the downstream end of the test section, where the fluid flow is the most developed. Performance, measured by percent error in UFM average reading with respect to the TFM average reading, generally improved with increasing flow rate at all locations, though absolute difference between meter readings increased with flow rate. This research suggests that ultrasonic approaches hold promise for non-invasive measurement of primary coolant flow in integral PWRs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electron Diamagnetic Effect on Axial Force in an Expanding Plasma: Experiments and Theory

The axial force imparted from a magnetically expanding current-free plasma is directly measured for three different experimental configurations and compared with a two-dimensional fluid theory. The force component solely resulting from the expanding field is directly measured and identified as an axial force produced by the azimuthal current due to an electron diamagnetic drift and the radial component of the magnetic field. The experimentally measured forces are well described by the theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-interface Richtmyer-Meshkov turbulent mixing at the Los Alamos Vertical Shock Tube

We studied Mach number and initial conditions effects on Richtmyer–Meshkov (RM) mixing by the vertical shock tube (VST) at Los Alamos National Laboratory (LANL). At the VST, a perturbed stable light-to-heavy (air–SF 6 , A=0.64) interface is impulsively accelerated with a shock wave to induce RM mixing. We investigate changes to both large and small scales of mixing caused by changing the incident Mach number (Ma=1.3 and 1.45) and the three-dimensional (3D) perturbations on the interface. Simultaneous density (quantitative planar laser-induced fluorescence (PLIF)) and velocity (particle image velocimetry (PIV)) measurements are used to characterize preshock initial conditions and the dynamic shocked interface. Initial conditions and fluid properties are characterized before shock. Using two types of dynamic measurements, time series (N=5 realizations at ten locations) and statistics (N=100 realizations at a single location) of the density and velocity fields, we calculate several mixing quantities. Mix width, density-specific volume correlations, density–vorticity correlations, vorticity, enstrophy, strain, and instantaneous dissipation rate are examined at one downstream location. Results indicate that large-scale mixing, such as the mix width, is strongly dependent on Mach number, whereas small scales are strongly influenced by initial conditions. Lastly, the enstrophy and strain show focused mixing activity in the spike regions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging viscous flow of the Dirac fluid in graphene

The electron–hole plasma in charge-neutral graphene is predicted to realize a quantum critical system in which electrical transport features a universal hydrodynamic description, even at room temperature. This quantum critical ‘Dirac fluid’ is expected to have a shear viscosity close to a minimum bound, with an interparticle scattering rate saturating1 at the Planckian time, the shortest possible timescale for particles to relax. Although electrical transport measurements at finite carrier density are consistent with hydrodynamic electron flow in graphene a clear demonstration of viscous flow at the charge-neutrality point remains elusive. In this work, we directly image viscous Dirac fluid flow in graphene at room temperature by measuring the associated stray magnetic field. Nanoscale magnetic imaging is performed using quantum spin magnetometers realized with nitrogen vacancy centres in diamond. Scanning single-spin and wide-field magnetometry reveal a parabolic Poiseuille profile for electron flow in a high-mobility graphene channel near the charge-neutrality point, establishing the viscous transport of the Dirac fluid. This measurement is in contrast to the conventional uniform flow profile imaged in a metallic conductor and also in a low-mobility graphene channel. Furthermore, via combined imaging and transport measurements, we obtain viscosity and scattering rates, and observe that these quantities are comparable to the universal values expected at quantum criticality. This finding establishes a nearly ideal electron fluid in charge-neutral, high-mobility graphene at room temperature4. Our results will enable the study of hydrodynamic transport in quantum critical fluids relevant to strongly correlated electrons in high-temperature superconductors9. This work also highlights the capability of quantum spin magnetometers to probe correlated electronic phenomena at the nanoscale.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Spring constant calibration of atomic force microscope cantilevers of arbitrary shape

The spring constant of an atomic force microscope cantilever is often needed for quantitative measurements. The calibration method of Sader et al. [Rev. Sci. Instrum. 70, 3967 (1999)] for a rectangular cantilever requires measurement of the resonant frequency and quality factor in fluid (typically air), and knowledge of its plan view dimensions. This intrinsically uses the hydrodynamic function for a cantilever of rectangular plan view geometry. Here, we present hydrodynamic functions for a series of irregular and non-rectangular atomic force microscope cantilevers that are commonly used in practice. Cantilever geometries of arrow shape, small aspect ratio rectangular, quasi-rectangular, irregular rectangular, non-ideal trapezoidal cross sections, and V-shape are all studied. This enables the spring constants of all these cantilevers to be accurately and routinely determined through measurement of their resonant frequency and quality factor in fluid (such as air). An approximate formulation of the hydrodynamic function for microcantilevers of arbitrary geometry is also proposed. Implementation of the method and its performance in the presence of uncertainties and non-idealities is discussed, together with conversion factors for the static and dynamic spring constants of these cantilevers. These results are expected to be of particular value to the design and application of micro- and nanomechanical systems in general.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty Quantification by Monte Carlo Analysis using CFD Simulations for GEMIX Benchmark Activities

Uncertainty quantification (UQ) methods can be applied to computational fluid dynamics (CFD) simulations for determining the uncertainty bands of the simulations results. In order to determine the applicability of these different methods, simple benchmark activities have been conducted by various group for comparison. The GEMIX (Generic Mixing experiment) test facility was used to develop benchmark data for this purpose by the Paul Scherrer Institute (PSI). The facility involves the mixing of two fluids that are initially separated. One of the two fluids is water with sugar dissolved in it to create a fluid with similar fluid properties to water, except for density. The other fluid was distilled water to reduce the uncertainty in the fluid's properties. During the experiments, velocity fields and concentration measurements were acquired at several planes of interest. The velocity fields were acquired using particle image velocimetry (PIV) and concentrations of each fluid were acquired using laser induced fluorescence (LIF). The inlet velocity profiles were acquired using laser Doppler velocimetry (LDV). The activity provided the opportunity to vary turbulence models, meshing methodologies, and numerical schemes for creation of uncertainty estimates. The present study investigates the usage of a simple Monte Carlo (MC) technique for varying the inlet boundary conditions of each inlet. The velocity profiles and densities of each inlet were specifically varied based on experiment measurement uncertainty. The intent was to isolate the uncertainty due to inlet quantities and not related to meshing, numerical scheme, or turbulence models. The comparisons of experimental and simulation results were found to be reasonably accurate. Though deficiencies were identified in the modeling approach to be corrected in future works by the authors. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Complexity of Fault Rupture and Fluid Leakage in Shale: Insights From a Controlled Fault Activation Experiment

Abstract We observed rupture growth caused by controlled fluid injections at 340‐m depth within a fault zone in the low‐permeability Opalinus Clay in the Mont Terri Underground Research Laboratory (Switzerland). The rupture mechanisms were evaluated using measurements of the three‐component borehole wall displacements and fluid pressure in two sections of the fault zone and located horizontally 3 m apart from each other. One section was set across a secondary segment of the fault and used for stepwise fluid injection intended to trigger rupture growth. The other section was set across the principal shear zone of the fault for monitoring. After stepwise pressure increase up to 5.95 MPa at injection, rupture initiated as slip activation, followed by an overall opening of the fault planes connected to the injection. After 19 s of continued injection, displacements arrived at the monitoring point on the principal shear zone. These displacements are about 2.4 times larger than in the secondary fault segment. Overall, the displacements corresponded to a normal fault activation. About 9 s after the displacement front arrived, a strong pressure increase of 4.17 MPa was measured at the monitoring point, indicating a hydraulic connection had formed along the initially very low permeability fault planes between the injection and the monitoring points. Our analyses highlight that the fault activation is consistent with the state of stress but that injection pressure must be close to the normal stress acting on the fault for permeability to be generated and for fluid leakage to occur.

Guglielmi, Yves↗