Search NASA⌕ Search

SEARCH · Search NASA

Results for “Factorization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Factorized QED and QCD contribution to deeply inelastic scattering

We present the first calculation of next-to-leading order (NLO) factorized QED and QCD contributions to the short-distance hard coefficients of inclusive lepton-hadron deep inelastic scattering (DIS) in a joint QED and QCD factorization approach. Unlike the traditional radiative correction approach to handle the collision-induced QED contributions to DIS, QED radiation from all charged leptons and quarks are treated equally, and their collinear sensitivities are systematically factorized into corresponding universal lepton and parton distribution functions. We demonstrate that the NLO factorized short-distance QED contribution is completely infrared safe and calculable without the need of any parameters other than the standard factorization scale in the same way as the factorized short-distance QCD contribution. We discuss the potential impact of this joint factorization approach on the extraction of partonic information from lepton-hadron DIS.

Deep inelastic scattering↗

Extraction of the neutron electric form factor from measurements of inclusive double spin asymmetries

Background: Measurements of the neutron charge form factor, G$n\atop{E}$, are challenging because the neutron has no net charge. Additionally, measurements of the neutron form factors must use nuclear targets which require accurately accounting for nuclear effects. Extracting G$n\atop{E}$ with different targets and techniques provides an important test of our handling of these effects. Purpose: The goal of the measurement was to use an inclusive asymmetry measurement technique to extract the neutron charge form factor at a four-momentum transfer of 1 (GeV/c) 2 . This technique has very different systematic uncertainties than traditional exclusive measurements and thus serves as an independent check of whether nuclear effects have been taken into account correctly. Method: The inclusive quasielastic reaction 3 $→\atop{He}$ ($→\atop{e}$, e') was measured at Jefferson Laboratory. The neutron electric form factor, G$n\atop{E}$, was extracted at Q 2 = 0.98 ( GeV/c) 2 from ratios of electron-polarization asymmetries measured for two orthogonal target spin orientations. This Q 2 is high enough that the sensitivity to G$n\atop{E}$ is not overwhelmed by the neutron magnetic contribution, and yet low enough that explicit neutron detection is not required to suppress pion production. Results: The neutron electric form factor, G$n\atop{E}$, was determined to be 0.0414 ± 0.0077 ( stat ) ± 0.0022 ( syst ), providing the first high-precision inclusive extraction of the neutron's charge form factor. In conclusion: The use of the inclusive quasielastic 3 $→\atop{He}$ ($→\atop{e}$, e') with a four-momentum transfer near 1 (GeV/c) 2 has been used to provide a unique measurement of G$n\atop{E}$. This new result provides a systematically independent validation of the exclusive extraction technique results and implies that the nuclear corrections are understood. This is contrary to the proton form factor where asymmetry and differential cross section measurements have been shown to have large systematic differences.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Local dynamics of proteins and DNA evaluated from crystallographic B factors

Distributions of scaled B factors from 704 protein–DNA complexes reflect primarily the neighbourhood of amino-acid and nucleotide residues: their flexibility grows from the protein core to protein–protein and protein–DNA interfaces, to solvent-exposed residues. Some of the findings clearly observed at higher resolution structures can no longer be observed for structures at low resolution indicating problems in refinement protocols. The dynamics of protein and nucleic acid structures is as important as their average static picture. The local molecular dynamics concealed in diffraction images is expressed as so-called B factors. To find out how the crystal-derived B factors represent the dynamic behaviour of atoms and residues of proteins and DNA in their complexes, the distributions of scaled B factors from a carefully curated data set of over 700 protein–DNA crystal structures were analyzed [Schneider et al. (2014 ▶), Nucleic Acids Res.42, 3381–3394]. Amino acids and nucleotides were categorized based on their molecular neighbourhood as solvent-accessible, solvent-inaccessible (i.e. forming the protein core) or lying at protein–protein or protein–DNA interfaces; the backbone and side-chain atoms were analyzed separately. The B factors of two types of crystal-ordered water molecules were also analyzed. The analysis confirmed several expected features of protein and DNA dynamics, but also revealed surprising facts. Solvent-accessible amino acids have B factors that are larger than those of residues at the biomolecular interfaces, and core-forming amino acids are the most restricted in their movement. A unique feature of the latter group is that their side-chain and backbone atoms are restricted in their movement to the same extent; in all other amino-acid groups the side chains are more floppy than the backbone. The low values of the B factors of water molecules bridging proteins with DNA and the very large fluctuations of DNA phosphates are surprising. The features discriminating different types of residues are less pronounced in structures with lower crystallographic resolution. Some of the observed trends are likely to be the consequence of improper refinement protocols that may need to be rectified.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of Coaxial Electrode Geometry on the Electric Field Enhancement Factor for a High Voltage Vacuum Gap

We present an experimental analysis of the change in the electric field enhancement factor with varying gap size and penetration depth (P.D) of cathode into anode for a coaxial vacuum gap, diagnosed using Fowler–Nordheim analysis and optical imaging via scanning electron microscope (SEM) and time integrated Digital single lens reflex camera (DSLR). Data were collected on the Coaxial Gap Breakdown Machine (240 A, 25 kV, 150 ns, 0.1 Hz). Experiments using five different gap sizes at nine different P.Ds are compared over runs comprising 50 shots for each case. The results show a strong link between enhancement factor and gap size, with P.D and surface topology. For large gap sizes, 150, 330, and 700 μm, the average enhancement factor value increases with increasing P.D. For smaller gap sizes, 50 and 100 μm, the average enhancement factor decreases with P.D. SEM imaging before and after plasma formation for each gap size allows for quantifying surface finish, microprotrusion growth, average blast diameter, and an estimation of the surface area breakdowns occupy. Time integrated DSLR imaging analysis of the gap at each shot allows for a determination of the distribution of breakdowns about the circumference of the gap for each case tested. Here, the Fowler–Nordheim analysis allows for a quantitative analysis of the surface roughness of all gap sizes tested. Results show that for large gap sizes, the gap geometry and increasing area of breakdown is the main cause for increasing average enhancement factor. For small gap sizes, the dominant driving factor for small average enhancement factors—that subsequently decrease with P.D—is significant changes in surface topology due to an increased number of breakdowns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Study on the Effect of Localized Blockages on the Friction Factor of a 61-Pin Wire-Wrapped Bundle

Abstract The thermal-hydraulic behavior of the flow in rod bundles has motivated numerous experimental and computational investigations. Previous studies have identified potential for accumulation of debris within the small subchannels of typical wire-wrapped assemblies with subsequent total or partial blockage of subchannel coolant flow. A test campaign was conducted to study the effects of localized blockages on the bundle averaged friction factor of a tightly packed wire-wrapped rod bundle. Blockages were installed within the bundle, and fluid pressure drop was measured across one wire pitch for a Reynolds number range of 500–17,200. The Darcy–Weisbach friction factor of the perturbed rod bundle geometry was compared with that of the unblocked bundle, as well as with the predictions of a well-established friction factor correlation. Differing effects based on blockage size and location for various flow regimes were studied. A number of conclusions can be made about the effects of the blockages on the friction factor, such as an increasing effect of the blockage on friction factor with an increase in Reynolds number, a change in flow behavior in the turbulent transition flow regime near Reynolds number 3000, differences in effect on friction factor for different types of subchannel blockage, and a nonlinear trend in friction factor variation with flow area impeded for edge subchannels. To this end, all data and quantified uncertainty produced in this study are made available for comparison and validation of advanced computational tools.

Engineering↗

Factors for converting dose measured in polystyrene phantoms to dose reported in water phantoms for incident proton beams

Purpose: Previous dosimetry protocols allowed calibrations of proton beamline dose monitors to be performed in plastic phantoms. Nevertheless, dose determinations were referenced to absorbed dose-to-muscle or absorbed dose-to-water. The IAEA Code of Practice TRS 398 recommended that dose calibrations be performed with ionization chambers only in water phantoms because plastic-to-water dose conversion factors were not available with sufficient accuracy at the time of its writing. These factors are necessary, however, to evaluate the difference in doses delivered to patients if switching from calibration in plastic to a protocol that only allows calibration in water. Methods: This work measured polystyrene-to-water dose conversion factors for this purpose. Uncertainties in the results due to temperature, geometry, and chamber effects were minimized by using special experimental set-up procedures. The measurements were validated by Monte Carlo simulations. Results: At the peak of non-range-modulated beams, measured polystyrene-to-water factors ranged from 1.015 to 1.024 for beams with ranges from 36 to 315 mm. For beams with the same ranges and medium sized modulations, the factors ranged from 1.005 to 1.019. The measured results were used to generate tables of polystyrene-to-water dose conversion factors. Conclusions: The dose conversion factors can be used at clinical proton facilities to support beamline and patient specific dose per monitor unit calibrations performed in polystyrene phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

Correction factors for ionization chamber dosimetry in CyberKnife: Machine-specific, plan-class, and clinical fields

Purpose: The aim of this work is the application of the formalism for ionization chamber reference dosimetry of small and nonstandard fields [R. Alfonso, P. Andreo, R. Capote, M. S. Huq, W. Kilby, P. Kjaell, T. R. Mackie, H. Palmans, K. Rosser, J. Seuntjens, W. Ullrich, and S. Vatnitsky, 'A new formalism for reference dosimetry of small and nonstandard fields,' Med. Phys. 35, 5179-5186 (2008)] to the CyberKnife robotic radiosurgery system. Correction factors for intermediate calibration fields, a machine-specific reference field (msr) and two plan-class specific reference fields (pcsr), have been studied. Furthermore, the applicability of the new formalism to clinical dosimetry has been analyzed through the investigation of two clinical treatments. Methods: PTW31014 and Scanditronix-Wellhofer CC13 ionization chamber measurements were performed for the fields under investigation. Absorbed dose to water was determined using alanine reference dosimetry, and experimental correction factors were calculated from alanine to ionization chamber readings ratios. In addition, correction factors were calculated for the intermediate calibration fields and one of the clinical treatment fields using the Monte Carlo method and these were compared with the experimental values. Results: Overall correction factors deviating from unity by approximately 2% were obtained from both measurements and simulations, with values below and above unity for the studied intermediate calibration fields and clinical fields for the ionization chambers under consideration. Monte Carlo simulations yielded correction factors comparable with those obtained from measurements for the machine-specific reference field, although differences from 1% to 3.3% were observed between measured and calculated correction factors for the composite intermediate calibration fields. Dose distribution inhomogeneities are thought to be responsible for such discrepancies. Conclusions: The differences found between overall correction factors associated with the proposed intermediate calibration fields and the clinical fields under investigation show that depending on the clinical field and the detector used, either a machine-specific reference field or a plan-class specific reference field is more representative for the clinical field. Given the experimental and numerical uncertainties and the small number of clinical fields considered in this study the significance of these observations is limited and it remains unclear for the CyberKnife if there would be a significant gain in using a pcsr field rather than a msr field as reference field for relative dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-246: MU Model Implementation for a Passively Scattered Proton Beam: Inclusion of the Bolus Gap and Nozzle Extension Factors

Purpose: To develop and implement an MU model for a passively scattered proton beam, and eliminate the need for patient specific calibrations for field sizes from 3cm to 15cm. This would enable consistent and timely calibrations for a wide variety of patient portals, streamlining the treatment process. Methods: Measurements were initially made using a Standard Imaging A-16 ion chamber and a modified water tank to determine the bolus gap factors (BGF) for multiple combinations of aperture size, bolus thickness, and air gap. The BGF was then separated into two component factors: the bolus thickness factor (BTF) and the nozzle extension factor (NEF). Polynomial curves were generated using the measured data to produce BTF tables for air gaps from 0cm to 30cm and for bolus thicknesses from 0cm to 10cm, and NEF tables for the full range of clinically used nozzle extensions. Additionally, data tables were created for every factor that affects beam output in the MU model. The MUs were then modeled for 487 patient portals and retrospectively compared to the MUs generated from the physical calibrations previously performed. Results: Of the 487 patient portals tested, 100% of the portals used for the comparison were within 2.5% from the MUs generated using a physical calibration, and 95.9% of the MU model portals tested were within 2%. The patient portals tested had field sizes ranging from 2.1cm to 10.1cm, with air gaps from 2cm to 25cm. Output factors for field sizes below 3cm with irregularly shaped fields demonstrated inconsistent results and will be further studied. Conclusion: The most problematic output factor, the BGF, was modeled accurately and consistently using the lowest order polynomial curve fits and interpolation between measured data. The study results demonstrate the robustness of the MU model and the potential for saving valuable personnel and beam time.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-491: Importance of Energy Dependent Protons Per MU Calibration Factors in IMPT Dose Calculations Using Monte Carlo Technique

Purpose: In intensity modulated proton therapy (IMPT), energy dependent, protons per monitor unit (MU) calibration factors are important parameters that determine absolute dose values from energy deposition data obtained from Monte Carlo (MC) simulations. Purpose of this study was to assess the sensitivity of MC-computed absolute dose distributions to the protons/MU calibration factors in IMPT. Methods: A “verification plan” (i.e., treatment beams applied individually to water phantom) of a head and neck patient plan was calculated using MC technique. The patient plan had three beams; one posterior-anterior (PA); two anterior oblique. Dose prescription was 66 Gy in 30 fractions. Of the total MUs, 58% was delivered in PA beam, 25% and 17% in other two. Energy deposition data obtained from the MC simulation were converted to Gy using energy dependent protons/MU calibrations factors obtained from two methods. First method is based on experimental measurements and MC simulations. Second is based on hand calculations, based on how many ion pairs were produced per proton in the dose monitor and how many ion pairs is equal to 1 MU (vendor recommended method). Dose distributions obtained from method one was compared with those from method two. Results: Average difference of 8% in protons/MU calibration factors between method one and two converted into 27 % difference in absolute dose values for PA beam; although dose distributions preserved the shape of 3D dose distribution qualitatively, they were different quantitatively. For two oblique beams, significant difference in absolute dose was not observed. Conclusion: Results demonstrate that protons/MU calibration factors can have a significant impact on absolute dose values in IMPT depending on the fraction of MUs delivered. When number of MUs increases the effect due to the calibration factors amplify. In determining protons/MU calibration factors, experimental method should be preferred in MC dose calculations. Research supported by National Cancer Institute grant P01CA021239.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-IeP1-03: Comparison of Monte Carlo Simulation and Conversion Factor Based Method On Estimation of Effective Dose in Pediatric Patients Undergoing Interventional Cardiac Procedures

Purpose: Interventional cardiac procedures utilize frequent fluoroscopy and cineangiography, which impose considerable radiation risk to patients, especially pediatric patients. Accurate calculation of effective dose is important in order to estimate cancer risk over the rest of their lifetime. This study evaluates the difference in effective dose calculated by Monte Carlo simulation with those estimated by locally-derived conversion factors (CF-local) and by commonly quoted conversion factors from Karambatsakidou et al (CF-K). Methods: Effective dose (E),of 12 pediatric patients, age between 2.5–19 years old, who had undergone interventional cardiac procedures, were calculated using PCXMC-2.0 software. Tube spectrum, irradiation geometry, exposure parameters and dose-area product (DAP) of each projection were included in the software calculation. Effective doses for each patient were also estimated by two Methods: 1) CF-local: conversion factor derived locally by generalizing results of 12 patients, multiplied by DAP of each patient gives E-local. 2) CF-K: selected factor from above-mentioned literature, multiplied by DAP of each patient gives E-K. Results: Mean of E, E-local and E-K were 16.01 mSv, 16.80 mSv and 22.25 mSv respectively. A deviation of −29.35% to +34.85% between E and E-local, while a greater deviation of −28.96% to +60.86% between E and EK were observed. E-K overestimated the effective dose for patients at age 7.5–19. Conclusion: Effective dose obtained by conversion factors is simple and quick to estimate radiation risk of pediatric patients. This study showed that estimation by CF-local may bear an error of 35% when compared with Monte Carlo calculation. If using conversion factors derived by other studies may result in an even greater error, of up to 60%, due to factors that are not catered for in the estimation, including patient size, projection angles, exposure parameters, tube filtration, etc. Users must be aware of these potential inaccuracies when simple conversion method is employed.

60 APPLIED LIFE SCIENCES↗

Virulence factors and antimicrobial resistance profiles of Campylobacter isolates recovered from consecutively reused broiler litter

ABSTRACT Campylobacterinfections are a leading cause of bacterial diarrhea in humans globally. Infections are due to consumption of contaminated food products and are highly associated with chicken meat, with chickens being an important reservoir forCampylobacter. Here, we characterized the genetic diversity ofCampylobacter jejuni(C. jejuni) andCampylobacter coli(C. coli) detected in broiler chicken litter over three consecutive flocks and determined their antimicrobial resistance (ARM) and virulence factor (VF) profiles.Campylobacterwas detected in 9.38% (27/288) of litter samples collected. Antimicrobial susceptibility testing and whole genome sequencing were performed onC. jejuni(n= 39) andC. coli(n= 5) isolates.Campylobactervirulence factors differed within and across broiler houses but were explained by the broiler flock cohort raised on litter,Campylobacterspecies andCampylobactermultilocus sequence type (MLST). Virulence factors involved in the ability to invade and colonize host tissues and evade host defenses were present inC. jejuniisolates (ST-464) from flock cohorts 1 and 2 but absent inC. jejuniisolates (ST-48) from flock cohort 3.C. jejuniisolates from house three harbored a significantly higher proportion of virulence genes with functions related to glycosylation and immune evasion thanC. jejuniisolates from houses 1 and 2 (P< 0.01). AllC. jejuniisolates were susceptible to all antibiotics tested whileC. coli(n= 4) were resistant to tetracycline and harbored the tetracycline resistant ribosomal protection protein (TetO). Our results suggest that house environment and broiler management practices imposed selective pressures on virulence factors and antimicrobial resistance genes ofCampylobacter. IMPORTANCE Campylobacteris a leading cause of foodborne illness in the United States due to consumption of contaminated or mishandled food products, often associated with chicken meat.Campylobacteris common in the microbiota of avian and mammalian gut; however, acquisition of antimicrobial resistance genes (ARGs) and virulence factors (VFs) may result in strains that pose significant threat to public health. Although there are studies investigating the genetic diversity ofCampylobacterstrains isolated from post-harvest chicken samples, there are limited data on the genome characteristics of isolates recovered from preharvest broiler production. Here, we show thatCampylobacter jejuniandCampylobacter colidiffer in their carriage of antimicrobial resistance and virulence factors may also differ in their ability to persist in litter during consecutive grow-out of broiler flocks. We found that presence/absence of virulence factors needed for evasion of host defense mechanisms and gut colonization played an integral role in differentiatingCampylobacterstrains.

Microbiology↗

The role of chromatin accessibility in directing the widespread, overlapping patterns of Drosophila transcription factor binding

Background: In Drosophila embryos, many biochemically and functionally unrelated transcription factors bind quantitatively to highly overlapping sets of genomic regions, with much of the lowest levels of binding being incidental, non-functional interactions on DNA. The primary biochemical mechanisms that drive these genomewide occupancy patterns have yet to be established. Results: Here we use data resulting from the DNaseI digestion of isolated embryo nuclei to provide a biophysical measure of the degree to which proteins can access different regions of the genome. We show that the in vivo binding patterns of 21 developmental regulators are quantitatively correlated with DNA accessibility in chromatin. Furthermore, we find that levels of factor occupancy in vivo correlate much more with the degree of chromatin accessibility than with occupancy predicted from in vitro affinity measurements using purified protein and naked DNA. Within accessible regions, however, the intrinsic affinity of the factor for DNA does play a role in determining net occupancy, with even weak affinity recognition sites contributing. Finally, we show that programmed changes in chromatin accessibility between different developmental stages correlate with quantitative alterations in factor binding. Conclusions: Based on these and other results, we propose a general mechanism to explain the widespread, overlapping DNA binding by animal transcription factors. In this view, transcription factors are expressed at sufficiently high concentrations in cells such that they can occupy their recognition sequences in highly accessible chromatin without the aid of physical cooperative interactions with other proteins, leading to highly overlapping, graded binding of unrelated factors.

59 BASIC BIOLOGICAL SCIENCES↗

NREM sleep as a novel protective cognitive reserve factor in the face of Alzheimer's disease pathology

Alzheimer’s disease (AD) pathology impairs cognitive function. Yet some individuals with high amounts of AD pathology suffer marked memory impairment, while others with the same degree of pathology burden show little impairment. Why is this? One proposed explanation is cognitive reserve i.e., factors that confer resilience against, or compensation for the effects of AD pathology. Deep NREM slow wave sleep (SWS) is recognized to enhance functions of learning and memory in healthy older adults. However, that the quality of NREM SWS (NREM slow wave activity, SWA) represents a novel cognitive reserve factor in older adults with AD pathology, thereby providing compensation against memory dysfunction otherwise caused by high AD pathology burden, remains unknown. Here, we tested this hypothesis in cognitively normal older adults (N = 62) by combining 11 C-PiB (Pittsburgh compound B) positron emission tomography (PET) scanning for the quantification of β-amyloid (Aβ) with sleep electroencephalography (EEG) recordings to quantify NREM SWA and a hippocampal-dependent face-name learning task. We demonstrated that NREM SWA significantly moderates the effect of Aβ status on memory function. Specifically, NREM SWA selectively supported superior memory function in individuals suffering high Aβ burden, i.e., those most in need of cognitive reserve (B = 2.694, p = 0.019). In contrast, those without significant Aβ pathological burden, and thus without the same need for cognitive reserve, did not similarly benefit from the presence of NREM SWA (B = -0.115, p = 0.876). This interaction between NREM SWA and Aβ status predicting memory function was significant after correcting for age, sex, Body Mass Index, gray matter atrophy, and previously identified cognitive reserve factors, such as education and physical activity (p = 0.042). These findings indicate that NREM SWA is a novel cognitive reserve factor providing resilience against the memory impairment otherwise caused by high AD pathology burden. Furthermore, this cognitive reserve function of NREM SWA remained significant when accounting both for covariates, and factors previously linked to resilience, suggesting that sleep might be an independent cognitive reserve resource. Beyond such mechanistic insights are potential therapeutic implications. Unlike many other cognitive reserve factors (e.g., years of education, prior job complexity), sleep is a modifiable factor. As such, it represents an intervention possibility that may aid the preservation of cognitive function in the face of AD pathology, both present moment and longitudinally.

60 APPLIED LIFE SCIENCES↗

Weak Dispersion of Exciton Landé Factor with Band Gap Energy in Lead Halide Perovskites: Approximate Compensation of the Electron and Hole Dependences

The optical properties of lead halide perovskite semiconductors in vicinity of the bandgap are controlled by excitons, so that investigation of their fundamental properties is of critical importance. The exciton Landé or g-factor g X is the key parameter, determining the exciton Zeeman spin splitting in magnetic fields. The exciton, electron, and hole carrier g-factors provide information on the band structure, including its anisotropy, and the parameters contributing to the electron and hole effective masses. Here, g X is measured by reflectivity in magnetic fields up to 60 T for lead halide perovskite crystals. The materials band gap energies at a liquid helium temperature vary widely across the visible spectral range from 1.520 up to 3.213 eV in hybrid organic–inorganic and fully inorganic perovskites with different cations and halogens: FA 0.9 Cs 0.1 PbI 2.8 Br 0.2 , MAPbI 3 , FAPbBr 3 , CsPbBr 3 , and MAPb(Br 0.05 Cl 0.95 ) 3 . The exciton g-factors are found to be nearly constant, ranging from +2.3 to +2.7. Thus, the strong dependences of the electron and hole g-factors on the bandgap roughly compensate each other when combining to the exciton g-factor. The same is true for the anisotropies of the carrier g-factors, resulting in a nearly isotropic exciton g-factor. The experimental data are compared favorably with model calculation results.

36 MATERIALS SCIENCE↗

Human Factors and Technologies Design to Improve User Acceptance of Pooled Rideshare for Increasing Transportation System Energy Efficiency

This multi-year project delivered a comprehensive, human-factors-driven framework to understand, model, and improve pooled rideshare (PR) adoption in the United States. Through three large-scale national survey studies involving more than 16,000 participants across multiple cities and demographic groups, the research established one of the most extensive datasets to date on user perceptions, behavioral barriers, and service expectations related to pooled rideshare. These data revealed key human factors barriers of user acceptance of PR and suggested potential actionable experience optimizations that could lead to increased PR usage. This foundational knowledge guided the development of novel human-factors models and behavioral choice models that quantify how psychological, demographic, and trip-level factors influence willingness to pool. Building on these empirical insights, the project developed advanced behavioral modeling tools, including mixed logit and integrated choice and latent variable models, to capture both observable and latent influences on PR adoption. These models significantly improved the ability to predict riders’ acceptance of pooled trips, explaining choice heterogeneity through latent constructs such as safety, service experience, privacy concerns, time sensitivity, and environmental attitudes. Together, these models provide a robust analytical foundation for designing PR systems that more effectively meet user needs. The project translated human-factors insights and behavioral models into actionable technology innovations by extending POLARIS—an agent-based, activity-based travel simulation platform—into a fully functional pooled rideshare simulation environment. New PR modules, acceptance models, and regional scenarios were implemented for Greenville, SC and Austin, TX, enabling high-fidelity validation of algorithmic strategies under realistic demand and traffic conditions. The simulation platform supported the development and evaluation of adaptive discount-based assignment algorithms, enhanced willingness-to-pay formulations, demographic-aware incentive mechanisms, and a proactive joint assignment and repositioning strategy. Simulation results demonstrated substantial gains in pooling uptake, average vehicle occupancy, energy efficiency, and fleet profitability. In Greenville, pooling adoption more than doubled, while reductions in vehicle-miles traveled and energy consumption were significant. In Austin, pooling improvements were achieved with minimal service-quality trade-offs, and profitability increased across all fleet sizes. Through this research, we developed a comprehensive understanding of the human factors barriers that limit user acceptance of pooled rideshare services. These insights enabled the design of human-factors-aware pooled rideshare technologies that more effectively address user concerns and improve adoption rates. By integrating these models into an advanced agent-based simulation framework, we demonstrated that higher adoption of pooled rideshare can lead to measurable improvements in energy efficiency and system performance. Together, these contributions establish a validated pathway from human-centered analysis to technology development and energy-saving outcomes, supporting national goals for more sustainable and efficient mobility systems.

Jia, Yunyi↗

Factorized QED Contribution to Lepton-Hadron DIS

We present the first calculation of next-to-leading order (NLO) factorized QED contributions to the short-distance hard coefficients of inclusive lepton-hadron deep inelastic scattering (DIS) in a joint QCD and QED factorization approach. We demonstrate how the joint factorization consistently factorize all perturbative collinear sensitivities of partonic scattering in both QCD and QED into corresponding universal hadron and lepton distribution functions without the need of any parameters other than the standard factorization scale. We discuss the necessary modification to DGLAP-type evolution of the parton and lepton distribution functions in this joint factorization approach. We also discuss the potential impact of this joint factorization approach on the extraction of partonic information from lepton-hadron DIS.

Qiu, Jianwei↗

Factorized visual representations in the primate visual system and deep neural networks

Object classification has been proposed as a principal objective of the primate ventral visual stream and has been used as an optimization target for deep neural network models (DNNs) of the visual system. However, visual brain areas represent many different types of information, and optimizing for classification of object identity alone does not constrain how other information may be encoded in visual representations. Information about different scene parameters may be discarded altogether (‘invariance’), represented in non-interfering subspaces of population activity (‘factorization’) or encoded in an entangled fashion. In this work, we provide evidence that factorization is a normative principle of biological visual representations. In the monkey ventral visual hierarchy, we found that factorization of object pose and background information from object identity increased in higher-level regions and strongly contributed to improving object identity decoding performance. We then conducted a large-scale analysis of factorization of individual scene parameters – lighting, background, camera viewpoint, and object pose – in a diverse library of DNN models of the visual system. Models which best matched neural, fMRI, and behavioral data from both monkeys and humans across 12 datasets tended to be those which factorized scene parameters most strongly. Notably, invariance to these parameters was not as consistently associated with matches to neural and behavioral data, suggesting that maintaining non-class information in factorized activity subspaces is often preferred to dropping it altogether. Thus, we propose that factorization of visual scene information is a widely used strategy in brains and DNN models thereof.

59 BASIC BIOLOGICAL SCIENCES↗

Loss Factor of Tapered Structures for Short Bunches

Using the electromagnetic simulation code ECHO, we have found a simple phenomenological formula that accurately describes the loss factor for short bunches traversing an axisymmetric tapered collimator. In this paper, we consider tapered collimators with rectangular cross-section and use the GdfidL code to calculate the loss factor dependence on the geometric parameters for short bunches. The results for both axisymmetric and rectangular collimators are discussed. The behaviour of the impedance of tapered structures for very short bunches in the optical regime has been determined in refs. [10,11]. Here, for the loss factors for two particular geometries, we have studied the departure from the optical regime behaviour as bunch length is increased. In both cases, the ratio of the loss factor for the tapered collimator to the loss factor in the optical regime is a function only of the scaling parameter {sigma}L/d{sup 2}. The fact that the bunch length a and the taper length L appear as a product is consistent with the recent scaling derived by Stupakov in ref. [12], since there is only a weak dependence on g. One noteworthy fact that is not a priori expected is that only the larger radius or vertical half-aperture d appears. The reduction factor is independent of b. Moreover, it is striking that the specific form involving the arctan given in Eq. (5) holds for both geometries, with only the coefficient {mu} differing by a factor of {approx}2 for flat vs round. This suggests that there may be a useful phenomenological form for more general geometries which may follow from natural extensions of Eq. (5). This possibility is presently being investigated.

43 PARTICLE ACCELERATORS↗