Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

MO-F-CAMPUS-J-02: Commissioning of Radiofrequency Tracking for Gated SBRT of the Liver Using Novel Motion System

Purpose: Tracking soft tissue targets has recently been approved as a new application of the Calypso radiofrequency tracking system allowing for gated treatment of the liver based on the motion of the target volume itself. As part of the commissioning process, an end-to-end test was performed using a 3D diode array and 6D motion platform to verify the dosimetric accuracy and establish the workflow of gated SBRT treatment of the liver using Calypso. Methods: A 4DCT scan of the ScandiDos Delta4 phantom was acquired using the HexaMotion motion platform to simulate realistic breathing motion. A VMAT plan was optimized on the end of inspiration phase of the 4DCT scan and delivered to the Delta4 phantom using the Varian TrueBeam. The treatment beam was gated by Calypso to deliver dose at the end of inspiration. The expected dose was compared to the delivered dose using gamma analysis. In addition, gating limits were investigated to determine how large the gating range can be while still maintaining dosimetric accuracy. Results: The 3%/3mm and 2%/2mm gamma pass rate for the gated treatment delivery was 100% and 98.4%, respectively. When increasing the gating limits beyond the known extent of planned motion from the 4DCT, the gamma pass rates decreased as expected. The 3%/3mm gamma pass rate for a 1, 2, and 3mm increase in gating limits were measured to be 96.0%, 92.7%, and 78.8%, respectively. Conclusion: Radiofrequency tracking was shown to be an effective way to provide gated SBRT treatment of the liver. Baseline gating limits should be determined by measuring the extent of target motion during the respiratory phases used for planning. We recommend adding 1mm to the baseline limits to provide the proper balance between treatment efficiency and dosimetric accuracy.

60 APPLIED LIFE SCIENCES↗

Embedding a Critical Point in a Hadron to Quark–Gluon Crossover Equation of State

It is shown how to embed a critical point in a smooth background equation of state so as to yield the critical exponents and critical amplitude ratios expected of a transition in the same universality class as the liquid–gas phase transition and the 3D Ising model. There are only two independent critical exponents; the relations α + 2β + $\gamma$ = 2 and β(δ - 1) = $\gamma$ arise automatically, as does a new relation between the two critical amplitudes. The resulting equation of state has parameters which may be inferred by hydrodynamic modeling of heavy-ion collisions in the Beam Energy Scan II at the Relativistic Heavy Ion Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Model-based versus specific dosimetry in diagnostic context: Comparison of three dosimetric approaches

Purpose: The dosimetric assessment of novel radiotracers represents a legal requirement in most countries. While the techniques for the computation of internal absorbed dose in a therapeutic context have made huge progresses in recent years, in a diagnostic scenario the absorbed dose is usually extracted from model-based lookup tables, most often derived from International Commission on Radiological Protection (ICRP) or Medical Internal Radiation Dose (MIRD) Committee models. The level of approximation introduced by these models may impact the resulting dosimetry. The aim of this work is to establish whether a more refined approach to dosimetry can be implemented in nuclear medicine diagnostics, by analyzing a specific case. Methods: The authors calculated absorbed doses to various organs in six healthy volunteers administered with flutemetamol ({sup 18}F) injection. Each patient underwent from 8 to 10 whole body 3D PET/CT scans. This dataset was analyzed using a Monte Carlo (MC) application developed in-house using the toolkit GATE that is capable to take into account patient-specific anatomy and radiotracer distribution at the voxel level. They compared the absorbed doses obtained with GATE to those calculated with two commercially available software: OLINDA/EXM and STRATOS implementing a dose voxel kernel convolution approach. Results: Absorbed doses calculated with GATE were higher than those calculated with OLINDA. The average ratio between GATE absorbed doses and OLINDA’s was 1.38 ± 0.34 σ (from 0.93 to 2.23). The discrepancy was particularly high for the thyroid, with an average GATE/OLINDA ratio of 1.97 ± 0.83 σ for the six patients. Differences between STRATOS and GATE were found to be higher. The average ratio between GATE and STRATOS absorbed doses was 2.51 ± 1.21 σ (from 1.09 to 6.06). Conclusions: This study demonstrates how the choice of the absorbed dose calculation algorithm may introduce a bias when gamma radiations are of importance, as is the case in nuclear medicine diagnostics.

60 APPLIED LIFE SCIENCES↗

SU-E-J-204: Can a Commercial System for MR-IGRT Be Used to Treat Patients Without Acquiring a CT Scan?

Patients treated using a magnetic-resonance image guided radiation therapy (MR-IGRT) system received both CT and MR simulations. During planning, the CT is used to determine relative electron density (RED) using a calibration table. This study aims to investigate the feasibility of MR-only treatments by comparing CT-computed dose distributions to those computed with combinations of water (1.0), lung (0.26), tissue (1.02), and bone (1.12) bulk RED overrides, and to identify the effects of the magnetic field on the RED-overridden doses. Methods: Four patients who received treatment using a commercial MR-IGRT system were analyzed (1 lung, 2 abdomen, and 1 pelvis). The clinical plans were computed using the first fraction MRI as primary, and the simulation CT as secondary for REDs. Plans were reoptimized using default bulk RED overrides (water/lung and tissue/lung for the lung patient, water/bone, tissue/bone, water only, and tissue only for the abdomen and pelvis patients). Additionally, each plan was re-optimized to include the static magnetic field. All plans were normalized to the same PTV coverage as the clinical plan. Dose-difference volumes and DVHs were computed for bulk density override plans, and 3D gamma analyses between each plan and its accompanying magnetic field plan were performed using 3%/3 mm dose difference and distance-to-agreement criteria using the PTV and Skin as masking structures. Results: The average differences in PTV and organs-at-risk mean dose for all RED combinations tested were −0.19 Gy (−0.62 – 0.06 Gy) and −0.34 Gy (−1.76 – 0.33 Gy), respectively. The average PTV and Skin gamma pass rates for all RED combinations tested were 99.88% (99.5% – 100%) and 98. 35% (96.3% – 99.6%). No systematic differences in DVHs or isodoses were observed. Conclusions: It is likely that that a commercial MR-IGRT system may produce high quality treatment plans without the need for CT scans. Authors of this abstract are members of the Washington University Radiation Oncology department, which has a research agreement with ViewRay, Inc.

60 APPLIED LIFE SCIENCES↗

Stereology of backscatter electron images of etched surfaces for characterization of particle size distributions and volume fractions: Estimation of imaging bias via Monte Carlo simulations

On metallic specimens in which a secondary phase has been selectively removed by a chemical etchant, the use of backscatter electron (BSE) imaging yields images that are more readily segmented with image processing algorithms than other modes of imaging in the scanning electron microscope. The contrast mechanisms in this imaging mode, however, produce a bias in the observation of particle sizes and volume fractions due to the effects of the electron interaction volume in the specimen. This stereological bias is quantified using Monte Carlo (MC) simulation of backscatter images. It is observed that the overprojection of features with centroids residing beneath the plane of polish is largely canceled out by the reduced segmentation size of features with centroids residing above the plane of polish. - Research Highlights: {yields} Backscatter imaging of selectively-etched surfaces can facilitate segmentation. {yields} Backscatter imaging of voids is simulated to estimate imaging/observation biases. {yields} The biases are quantified and incorporated into the stereological calculation. {yields} Systematic errors and imaging biases are observed to counteract one another. {yields} Results are illustrated using a bimodal gamma prime distribution in a Ni superalloy.

36 MATERIALS SCIENCE↗

Structural, Vibrational, Thermal And Electrical Characterization Of Gamma Radiation-Crosslinked Poly (Vinyl Alcohol)-Based Solid Polymer Electrolytes Blended With LiOH{center_dot}H{sub 2}O Salt

Solid polymer electrolytes based on poly(vinyl alcohol)(PVA) blended with different concentrations of LiOH{center_dot}H{sub 2}O salt were prepared using casting and {gamma}-irradiation techniques. The structure and blending of the poly-electrolytes were studied by X-ray diffraction (XRD) and Fourier transform Raman spectroscopy. The thermal properties of these solid polymer electrolytes were examined by thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC). The XRD spectra for the electrolytes indicated that the crystalline ratio of PVA decreases with the concentration of Lithium salt. Crystallinity, isotacticity and syndiotacticity percentages were also determined from Raman spectra at different salt concentrations revealing that the crystallinity and the Isotactic regularity of PVA molecule is reduced with salt addition, while the syndiotacticity increases linearly. DSC thermograms showed good accordance with these facts by detecting two melting temperatures corresponding to the two regularities, and these melting points change with the salt content. All characterizing techniques revealed the blend formation between LiOH{center_dot}H{sub 2}O salt and the polymer matrix. To account for the performance of the prepared solid polymer electrolytes, thermally stimulated depolarization current (TSDC) studies of the prepared blends were done. Short circuit TSDC at a polarizing temperature 353 K with a polarizing field of 3 kV cm{sup -1} have been analyzed in the temperature range 300-410 K. Two peaks are evident from the global TSDC measurements on the pure PVA homopolymer. Meanwhile, in all blended samples; there is only one broad peak with a shoulder on the high temperature side due to the relaxation of the poly-blend system. The prepared solid polymer electrolytes showed good charge storage capacity, and moderate current density values near the ambient.

36 MATERIALS SCIENCE↗

TU-AB-303-09: Investigation of Simple Method to Guide Adaptive Radiotherapy of Head-And-Neck Treatment Using Portal Imager

Purpose: Planned dose distribution for IMRT or VMAT could be altered by tissue changes during treatment course as in head and neck patients. Thus the aim of our study is to investigate a simple method that guides decision for re-planning. We will correlate changes in exit fluence tracked through entire treatment course with the anatomical changes. Methods: Fifteen patients were planned for IMRT; weekly CT scan was registered to original CT. Volume changes of different structures were assessed for each week. Frequently integrated images were acquired for all fields twice weekly via portal imager. The delivered fluences were compared with reference images. Gamma analysis (3% and 3 mm) including maximum γ, and percentage of points with γ≥ 1, were calculated for all fields. Results: Continuous reduction in GTV, CTV1 and parotids volumes during treatment was found [median value of 5.3 (1.3–20.8), 23.8 (3.0–128.7) and 1.7 (0.5–6.3) cm3 respectively] with significant change on week 2 (p= < 0.005). Also the value of gamma area >1 parameter continued to increase, significantly (P < 0.005), starting from second week (1.8 ± 1.9%) reaching 4.1 ± 1.6% by the end of treatment. Most of these changes in the exit fluences are significantly correlated to patient anatomy variations. Pearson correlation coefficient was −0.984 (P = 0.002) and −0.984 (P = 0.014) for the maximum gamma value and the value of gamma area >1, respectively. Conclusion: The changes in exit fluences are reflecting the corresponding anatomical changes. We proposed a method to track the changes in the averaged maximum gamma value and the gamma area > 1 value for the exit fluences during treatment. Maximum gamma value of 2.6% and Maximum gamma area > 1 value of 1.8% would be useful boarder lines that if exceeded a re-planning would be recommended.

60 APPLIED LIFE SCIENCES↗

Emittance Measurements at FAST Facility

The FAST facility at Fermilab recently been commissioned has demonstrated the generation of electron beam within a wide range of parameter (energy, charge) suitable for accelerator-science and beam-physics experiments. This accelerator consists of a photo-electron gun, injector, ILC-type cryomodules, and multiple downstream beam-lines. It will mainly serve as injector for the upcoming Integrable Optical Test Accelerator (IOTA). At the same time we will also carry out a LINAC based intense gamma ray experiment based on the Inverse Compton scattering. It is essential to understand the beam emittance for both experiments. A number of techniques are used to characaterizing the beam emittance including slit based method and quad scan method. An on-line emittance measurement based on multi-slit method is developed so the emittance measured will be immediately available to support further beam optimization. In this report we will present the results from the emittance studies using this tool. We will also present the emittance measurement based on quads scan technique for the high energy beam line.

43 PARTICLE ACCELERATORS↗

Microstructural study of the nickel-base alloy WAZ-20 using qualitative and quantitative electron optical techniques

The NASA nickel-base alloy WAZ-20 was analyzed by advanced metallographic techniques to qualitatively and quantitatively characterize its phases and stability. The as-cast alloy contained primary gamma-prime, a coarse gamma-gamma prime eutectic, a gamma-fine gamma prime matrix, and MC carbides. A specimen aged at 870 C for 1000 hours contained these same constituents and a few widely scattered high W particles. No detrimental phases (such as sigma or mu) were observed. Scanning electron microscope, light metallography, and replica electron microscope methods are compared. The value of quantitative electron microprobe techniques such as spot and area analysis is demonstrated.

Young, S. G.↗

Radiolytic Damage and Hydrogen Generation at Carbide – Water Interfaces

To understand the performance of carbides under irradiation, the behavior of SiC and ZrC as well as water slurries of these carbides have been systematically studied using gamma-rays and 5.5 MeV He ions. Radiolytic damage to the carbides was determined using a range of analytical techniques including thermogravimetric analysis (TGA), elemental analysis, inductively-coupled plasma optical emission spectroscopy (ICP-OES) and scanning electron microscopy-energy dispersive X-ray spectroscopy (SEM-EDS).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Contaminated Soil Volume Estimation at the Maywood Site - 12292

As part of the ongoing remediation process at the Maywood Formerly Utilized Sites Remedial Action Program properties, Argonne National Laboratory assisted the U.S. Army Corps of Engineers (USACE) New York District in revising contaminated soil volume estimates for the remaining areas of the Stepan/Sears properties that require soil remediation. As part of the volume estimation process, an initial conceptual site model (ICSM) was prepared for the entire site that captured existing information (with the exception of soil sampling results) pertinent to the possible location of surface and subsurface contamination above cleanup requirements. This ICSM was based on historical anecdotal information, aerial photographs, and the logs from several hundred soil cores that identified the depth of fill material and the depth to bedrock under the site. Specialized geostatistical software developed by Argonne was used to update the ICSM with historical sampling results and down-hole gamma survey information for hundreds of soil core locations; both sampling results and down-hole gamma data were coded to identify whether the results indicated the presence of contamination above site cleanup requirements. Significant effort was invested in developing complete electronic data sets for the site by incorporating data contained in various scanned documents, maps, etc. The updating process yielded both a best guess estimate of contamination volumes and upper and lower bounds on the volume estimate that reflected the estimate's uncertainty. The site-wide contaminated volume estimate (with associated uncertainty) was adjusted to reflect areas where remediation was complete; the result was a revised estimate of the remaining soil volumes requiring remediation that the USACE could use for planning. Other environmental projects may benefit from this process for estimating the volume of contaminated soil. A comparison of sample and DHG results for various stations with the site ICSM provides one measure of the quality of site understanding relative to the presence of contamination and its likely extent. A second measure of the quality of a contaminated soil volume estimate, in the case of BAASS, is a comparison of the best guess volume estimate with the conservative volume estimate. For Maywood, the conservative volume estimate is more than double the best guess. The data available for the site indicate that the preponderance of this difference is attributable to uncertainty about the exact depth of known contamination. The observed depth of contamination based on sample results and DHG data often varied significantly among adjacent soil cores. In the case of Maywood, where a significant amount of remediation has already taken place, a third measure of the quality of the volume estimates is the retrospective estimate of contaminated soil volumes for areas that have already been remediated [2]. The USACE is currently comparing the latest BAASS volume estimates for those areas with records indicating what was actually removed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Auger recombination in sodium-iodide scintillators from first principles

Scintillator radiation detectors suffer from low energy resolution that has been attributed to non-linear light yield response to the energy of the incident gamma rays. Auger recombination is a key non-radiative recombination channel that scales with the third power of the excitation density and may play a role in the non-proportionality problem of scintillators. In this work, we study direct and phonon-assisted Auger recombination in NaI using first-principles calculations. Our results show that phonon-assisted Auger recombination, mediated primarily by short-range phonon scattering, dominates at room temperature. We discuss our findings in light of the much larger values obtained by numerical fits to z-scan experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural and thermal properties of γ – irradiated Bombyx mori silk fibroin films

The gamma radiation-induced change in structural and thermal properties of Bombyx mori silk fibroin films were investigated and have been correlated with the applied radiation doses. Irradiation of samples were carried out in dry air at room temperature using Co-60 source, and radiation doses are in the range of 0 - 300 kGy. Structural and thermal properties of the irradiated silk films were studied using X-ray diffraction (XRD), Differential Scanning Calorimetry (DSC) and Thermogravimetric analysis (TGA) and compared with unirradiated sample. Interesting results are discussed in this report.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microstructure stability and micro-mechanical behavior of as-cast gamma-TiAl alloy during high-temperature low cycle fatigue

This paper systematically investigated the low cycle fatigue deformation of a high Nb-containing TiAl alloy with a nominal chemical composition of Ti-45Al-8.5Nb-0.2W-0.2B-0.02Y at 850 °C by using transmission electron microscopy (TEM), scanning electron microscopy (SEM), and synchrotron-based high-energy X-ray diffraction (HE-XRD) techniques. Cyclic stress-strain (CSS) behavior, lattice strain, and peak broadening of {100} α2 , {201} γ , and {202} ωo planes, phase transformations, and crack propagation behavior were obtained for samples with three total strain amplitudes: Δε t /2 = ±0.25%, Δε t /2 = ±0.28%, and Δε t /2 = ±0.30%. At early deformation stages, α 2lamellae transformed into ωo phase with a distinct orientation relationship, and a certain orientation relationship (OR) between them was observed after the following cyclic deformation. Furthermore, γ particles precipitated within the single ω o area. In addition, according to the peak intensity and peak broadening results, the ω o → B2 phase transformation occurred, leading to the appearance of single B2-phase areas. The lattice strains in the ω o phase were always in tension during the cyclic deformation and large differences of the lattice strains were found in the γ phase and α 2 phase, not only the values but also the directions, which resulted in crack nucleated at and propagated along the α 2 /γ lamellar interface. Finally, this study provides a better understanding of the low cycle fatigue deformation of TiAl alloys.

36 MATERIALS SCIENCE↗

Synthesis of flower-like Boehmite (AlOOH) via a simple solvothermal process without surfactant

Boehmite (AlOOH) with hierarchical flower-like structures was synthesized by the solvothermal reaction of AlCl{sub 3}.6H{sub 2}O in the presence of ethanol and toluene at 200 {sup o}C for 24 h. The product was characterized by X-ray powder diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The results show that boehmite with flower-like nanostructures, which aggregated together by the weak hydrogen bonds, was formed through dissolution-deposition process of boehmite microcrystals and the toluene has a great effect on the morphology of product in the reaction system. Meanwhile, the {gamma}-Al{sub 2}O{sub 3} was also obtained by calcination of above product at 500 {sup o}C for 2 h, and the flower-like morphology kept no change. The surface area of {gamma}-Al{sub 2}O{sub 3} powder was determined to be 166.8 m{sup 2}/g by N{sub 2} adsorption measurement. The possible formation mechanism of flower-like boehmite nanostructures was proposed and discussed.

36 MATERIALS SCIENCE↗

ON THE FORMATION OF Lyalpha EMISSION FROM RESONANTLY SCATTERED CONTINUUM PHOTONS OF GAMMA-RAY BURST's AFTERGLOW

The continuum spectrum of gamma-ray burst's (GRB) afterglow at Lyalpha wavelength is known to be otherwise featureless except for the existence of a pair of smooth damping wings. Resonant scattering of photons with the ambient neutral hydrogen around the GRB may alter this picture. We study the formation and evolution of the spectral imprint of these resonantly scattered photons in the context of GRB's afterglow. Based on an analytic model that includes photons that are scattered only once, as well as a complete treatment of all the scatterings using Monte Carlo simulations, we are able to calculate the spectrum and luminosity of this Lyalpha emission from a very early moment up to a late epoch. We find that the amount, the motion, and the geometry of the neutral hydrogen around the GRB, together with the time behavior of the source are the crucial factors that affect the predicted luminosity and spectral profile. The flux of the Lyalpha emission is found to be mainly contributed by photons that are scattered only once. The flux is of the order 10{sup -4}-10{sup -9} relative to the undecayed maximum flux of the transmitted continuum, making the feature negligible but potentially observable. If not obscured by the host galaxy's damped Lyalpha absorption systems or intergalactic neutral hydrogen, the feature may appear sometime from 1 hr to several years when the directly transmitted light has faded away. This scattered emission feature can be distinguished from Lyalpha photons of other origins by its luminosity evolution and by its gradual narrowing of profile with time. The typical timescale for spectral variance is that of the light crossing time of a hydrogen clump close to the GRB. If observed, the resonant peaks' time-dependent behavior is a scanning probe on the distribution of neutral hydrogen in GRB's immediate neighborhood.

79 ASTRONOMY AND ASTROPHYSICS↗

Quasi in-situ analysis of geometrically necessary dislocation density in α-fibre and γ-fibre during static recrystallization in cold-rolled low-carbon Ti-V bearing microalloyed steel

Highlights: • Average GND density is higher in gamma fibre than alpha fibre. • Higher drop in average GND density in un-recrystallized portion of gamma fibre • Fine precipitates pin the grain boundary at 700 °C 0 s. • Precipitates are coarse at 800 °C and present inside strain-free grains. - Abstract: In the present study, cold-rolled low-carbon steel is annealed at three different conditions: 700 °C for 0 s, 800 °C for 0 s and 800 °C for 2 min at the heating rate of ~10 °C/s. Recrystallization behaviour on sample surface is studied using a heated stage Scanning Electron Microscopy and Electron Backscattered Diffraction. For the lower annealing temperature of 700 °C with no dwell, almost no recrystallization is observed and microstructure resembles the as-received deformed material with the exception of occasional sub-micron sized nuclei. For the annealing conditions of 800 °C 0 s and 800 °C 2 min, onset and evolution of recrystallization is observed in-situ as a function of the initial as-cold rolled texture. Slower recovery rate of alpha fibre than gamma fibre is observed and confirmed by lower drop in average geometrically necessary dislocation (GND) density for un-recrystallized alpha fibres (1.1E+14 m{sup −2} for 700 °C 0 s, 1.4E+14 m{sup −2} for 800 °C 0 s and 4.5E+14 m{sup −2} for 800 °C 2 min) than for un-recrystallized gamma fibre grains (3.0E+14 m{sup −2} for 700 °C 0 s, 6.2E+14 m{sup −2} for 800 °C 0 s and 9.8E+14 m{sup −2} for 800 °C 2 min) during annealing. Strong gamma texture in recrystallized matrix is found for annealing conditions of 800 °C 0 s and 800 °C 2 min. From TEM characterisation it was shown that sub-grain boundaries are decorated with fine precipitates (diameter d < 15 nm) of titanium‑vanadium carbides (Ti,V)C for the annealing condition of 700 °C 0 s, which suggests that these precipitates play a major overall role in retardation of the recrystallization kinetics.

36 MATERIALS SCIENCE↗

SU-G-TeP2-07: Dosimetric Characterization of a New HDR Multi-Channel Esophageal Applicator for Brachytherapy

Purpose: To characterize the dose distribution of a new multi-channel esophageal applicator for brachytherapy HDR treatment, and particularly the effect of the presence of air or water in the applicator’s expansion balloon. Methods: A new multi-channel (6) inflatable applicator for esophageal HDR has been developed in house and tested in a simple water phantom. CT image sets were obtained under several balloon expansions (80ml of air, 50 cc of water), and channel loadings and used with the Oncentra (Elekta) planning system based on TG43 formalism. 400 cGy was prescribed to a plane 1cm away from the applicator. Planar dose distributions were measured for that plane and one next to the applicator using Gafchromic EBT3 film and scanned by a Vidar VXR-12 film digitizer. Film and TPS generated dose distributions of film were sent to OmniPro I’mRT (iba DOSIMETRY) for analysis. 2D dose profiles in both X and Y directions were compared and gamma analysis performed. Results: Film dose measurement of the air-inflated applicator is lower than the TPS calculated dose by as much as 60%. Only 80.8% of the pixels passed the gamma criteria (3%/3mm). For the water-inflated applicator, the measured film dose is fairly close to the TPS calculated dose (typically within <3%). 99.84% of the pixels passed the gamma criteria (3%/3mm). Conclusion: TG43 based calculations worked well when water was used in the expansion balloon. However, when air is present in that balloon, the neglect of heterogeneity corrections in the TG43 calculation results in large differences between calculated and measured doses. This could result in severe underdosing when used in a patient. This study illustrates the need for a TPS with an advanced algorithm which can account for heterogeneity. Supported by Innovations Department, Cleveland Clinic.

60 APPLIED LIFE SCIENCES↗