Search NASA⌕ Search

SEARCH · Search NASA

Results for “Human Performance Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Performance and Mass Modeling Subtleties in Closed-Brayton-Cycle Space Power Systems

A number of potential NASA missions could benefit from closed-Brayton-cycle (CBC) power conversion systems. The human and robotic mission power applications include spacecraft, surface base, and rover scenarios. Modeling of CBC subsystems allows system engineers, mission planners and project managers to make informed decisions regarding power conversion system characteristics and capabilities. To promote thorough modeling efforts, a critical review of CBC modeling techniques is presented. Analysis of critical modeling elements, component influences and cycle sensitivities is conducted. The analysis leads to quantitative results addressing projections on converter efficiency and overall power conversion system mass. Even moderate modeling errors are shown to easily over-predict converter efficiencies by 30% and underestimate mass estimates by 20%. Both static and dynamic modeling regimes are evaluated. Key considerations in determining model fidelity requirements are discussed. Conclusions and recommendations are presented that directly address ongoing modeling efforts in solar and nuclear space power systems.

Barrett, Michael J.↗

Soyuz Landing Reconstructions

Introduction: Recent data show a landing-attributed injury rate among Soyuz crew members to be higher than predicted in original certification analysis. New vehicles being developed for NASA are being certified using analytical tools to quantify injury risk. This assessment will provide data to allow the Agency to evaluate whether these tools are able to capture true injury risk and allow a comparison between Soyuz landings and upcoming vehicles. Methods: A finite element model (FEM) of the Soyuz descent module (DM) and its landing environment were developed to recreate Soyuz landing conditions. Occupant breakout models composed of the Soyuz seat and Sokol helmet were then developed to evaluate occupant response. These models included both anthropomorphic test device (ATD) and human body model (HBM) surrogates in three anthropometric sizes. A generalized distribution analysis of the Soyuz landing environment was performed using landing variable distributions from available literature. Results were used to identify trends in vehicle landing acceleration with landing conditions and to compare landing model injury risk predictions with those estimated in vehicle certification analysis. Next, historic Soyuz landings identified as inducing occupant injury during were reconstructed using the developed landing model and estimated landing conditions. Results and Discussion: This assessment demonstrated the capability of certification metrics, which include a combination of vehicle- and occupant-level injury risk analysis, to identify elevated injury risk landing conditions. However, the developed landing load predictions were limited by available vehicle and landing condition data. Additional data, particularly landing acceleration data specific to historic Soyuz landing conditions, would greatly enhance this assessment’s findings.

Preston Greenhalgh↗

A model-based analysis of a display for helicopter landing approach

A control theoretic model of the human pilot was used to analyze a baseline electronic cockpit display in a helicopter landing approach task and to generate display quickening laws designed to improve pilot-vehicle performance. A simple fixed base simulation provided comparative tracking data which allowed refinement of the pilot model.

Hess, R. A.↗

Use of Intermittent Recompression and Nitrox Breathing Mixtures during Lunar Extravehicular Activities

INTRODUCTION: NASA's plans for lunar surface exploration include pressurized suitport rovers that are quickly ingressed and egressed with minimal consumables losses. This capability enables crewmembers to perform multiple short extravehicular activities (EVAs) at different locations in a single day versus a single 8-hr EVA. Modeling work and empirical human and animal data indicate that intermittent recompressions between EVA suit pressure and cabin pressure reduce decompression stress. Savings in crew time and gas losses may also be achieved if the N2 purge is shortened to 2 minutes, achieving 80% O2 (vs. 8 minutes, 95% O2). METHODS: A validated Tissue Bubble Dynamics Model was used to predict decompression stress using 80% and 95% O2 breathing mixtures during 3 x 2-hr EVAs (4.3 PSIA) with 1hr recompressions back to 8.0 PSIA (32% O2) versus a single 8-hr EVA. 15 minutes was spent at 6.0 PSIA before depressurizations to 4.3 PSIA; initial EVA tasks could be performed during this time. Model validation was based on significant prediction (p<0.001) and goodness of fit with 84 cases of DCS in 668 altitude exposures (McFadden s rho-squared=0.214). RESULTS: A 2.2% predicted increase in DCS risk due to the shortened purge is more than compensated for by a predicted 2.5% reduction in DCS risk due to intermittent recompression. 15 minutes at 80% O2, 6.0 PSIA prior to a 4.3 PSIA EVA prevents supersaturation in the brain and spinal cord (5-10 minute half-time compartments) and reduces tissue tensions in 40 min compartments, where most of the body s inert gas is located, to approximately the same levels (4.39 vs 4.00 PSIA) as achieved during a 40 min 95% O2 prebreathe at 10.2 PSIA. CONCLUSIONS: Intermittent recompressions between lunar EVAs may enable reductions in suit purge and prebreathe requirements, decompression stress, and/or suit operating pressures.

Gernhardt, M.L.↗

Analysis of the Value Added When Deploying a Model-Based Approach for the Validation and Verification of the Medical Database Software

The Medical Database (MD) is a virtual repository consisting of two software components: Medical Item Database (MedID) and the Evidence Library (EL). MedID consists of engineering data and associated information for specific medical resource items (e.g., pharmaceutical, medical devices, and supporting components), while the EL is a tool which provides all of the medical evidence necessary. The MD will 1) serve as the single “source of truth” for the Informing Mission Planning via Analysis of Complex Tradespaces (IMPACT) tool suite for both medical evidence and medical resource engineering data and 2) will be used in conjunction with the IMPACT tool suite to inform research prioritizations and perform systematic trade study evaluations to aid stakeholders in making informed decisions regarding simulated human spaceflight missions. The MD project used a Model-Based Systems Engineering (MBSE) approach to support all life cycles of the software development, while in parallel the human factors engineering team used modeling to support Human Centered Design (HCD) strategies in an effort to improve software usability. HCD is a frequently used approach in design frameworks that develops resolutions to complexities and challenges by involving the human perspective in all steps of the problem-solving process. By integrating the model-based approaches used for systems engineering and human factors activities, the project is able to leverage the model-based artifacts originally created for HCD activities for system level and human factors validation. In this presentation, our team highlights the value added when leveraging these model-based artifacts to support the on-going verification and validation activities.

C. Laing↗

CHP-PRA: Sensorimotor Countermeasures Proof of Concept

The capabilities included in Crew Health and Performance (CHP) systems are designed to keep the crew healthy, happy, and productive. In doing so, the CHP system allows reductions in human related risks to be realized. All human missions, though particularly future Artemis and Mars missions, have constraints on the mass and volume allocated to the CHP system. Thus, trades must be made on how to best buy down risk while still meeting other requirements. Understanding how different CHP capabilities influence medical, performance, and long-term health risks is key to making informed choices among these trades. To address this, an integrated CHP Probabilistic Risk Assessment (PRA) model is being developed. Much like how IMPACT is designed to allow medical resource trades informed by medical risks, CHP PRA will enable analogous trades in human system risks across all CHP functions and capabilities. There are 29 Human System Risk Board (HSRB) risk areas to consider for model implementation. This effort focused solely on the implementation of countermeasures associated with sensorimotor risk. The framework and lessons learned from this proof of concept will benefit the implementation of other risks and countermeasures. Astronauts experience sensorimotor changes when entering or exiting a microgravity environment. While most sensorimotor issues are resolved within a few days, they pose a serious risk to crew health and performance during the adaptation period. This adaptation period aligns with gravity transitions and key mission phases where the crew members may be required to complete challenging tasks ideally with an undisturbed sensorimotor system. Countermeasures such as training or pharmaceuticals can be used to mitigate risk. This effort began by identifying physiological changes to the sensorimotor system that could lead to functional performance decrements or medical conditions and potential countermeasures, so that the overall effect of sensorimotor disturbance on human risk could be captured. We then selected example countermeasures, mapped relationships between countermeasures and outcomes, and used results from existing sensorimotor investigations to define the relationship between a sensorimotor countermeasure and subsequent performance of a sensorimotor-affected task. Specifically, using shuttle landing performance data, we compared the use or absence of inflight training capabilities to yield a relative performance change that can be applied to the prediction of the risk associated with manual control performance in future missions, as depicted in the figure. This sensorimotor proof of concept demonstrates how HRP research information can be transformed into quantifiable relationships to describe changes in HSRB medical and performance risks.

Caroline R Austin↗

Musculoskeletal Modeling Component of the NASA Digital Astronaut Project

The NASA Digital Astronaut Project s (DAP) objective is to provide computational tools that support research of the physiological response to low gravity environments and analyses of how changes cause health and safety risks to the astronauts and to the success of the mission. The spaceflight risk associated with muscle atrophy is impaired performance due to reduced muscle mass, strength and endurance. Risks of early onset of osteoporosis and bone fracture are among the spaceflight risks associated with loss of bone mineral density. METHODS: Tools under development include a neuromuscular model, a biomechanical model and a bone remodeling model. The neuromuscular model will include models of neuromuscular drive, muscle atrophy, fiber morphology and metabolic processes as a function of time in space. Human movement will be modeled with the biomechanical model, using muscle and bone model parameters at various states. The bone remodeling model will allow analysis of bone turnover, loss and adaptation. A comprehensive trade study was completed to identify the current state of the art in musculoskeletal modeling. The DAP musculoskeletal models will be developed using a combination of existing commercial software and academic research codes identified in the study, which will be modified for use in human spaceflight research. These individual models are highly dependent upon each other and will be integrated together once they reach sufficient levels of maturity. ANALYSES: The analyses performed with these models will include comparison of different countermeasure exercises for optimizing effectiveness and comparison of task requirements and the state of strength and endurance of a crew member at a particular time in a mission. DISCUSSION: The DAP musculoskeletal model has the potential to complement research conducted on spaceflight induced changes to the musculoskeletal system. It can help with hypothesis formation, identification of causative mechanisms and supplementing small data samples.

Lewandowski, B. E.↗

Parametric Modeling of the Safety Effects of NextGen Terminal Maneuvering Area Conflict Scenarios

The goal of this work was to analytically identify and quantify the issues, challenges, technical hurdles, and pilot-vehicle interface issues associated with conflict detection and resolution (CD&R)in emerging operational concepts for a NextGen terminal aneuvering area, including surface operations. To this end, the work entailed analytical and trade studies focused on modeling the achievable safety benefits of different CD&R strategies and concepts in the current and future airport environment. In addition, crew-vehicle interface and pilot performance enhancements and potential issues were analyzed based on review of envisioned NextGen operations, expected equipage advances, and human factors expertise. The results of perturbation analysis, which quantify the high-level performance impact of changes to key parameters such as median response time and surveillance position error, show that the analytical model developed could be useful in making technology investment decisions.

Rogers, William H.↗

Next Generation Exercise Device (NGED): Advancing Exercise Capabilities for Future Space Missions Through Biomechanical Modeling

BACKGROUND As space exploration extends to long-duration missions on the Moon and Mars, maintaining astronaut health and fitness becomes increasingly critical. The Next Generation Exercise Device (NGED), developed and tested by the HumanWorks Lab in NASA Johnson Space Center's (JSC) Software, Robotics, and Simulation Division, aims to address this challenge through innovative approaches. This study presents the development and evaluation of an NGED system, focusing on its adaptability to various mission scenarios, including prospective use in a Lunar Pressurized Rover (LPR). Central to this project is the application of biomechanical modeling to optimize exercise efficacy and safety in microgravity and partial gravity environments. The project is a collaborative effort with the Human Health and Performance group at Johnson Space Center, ensuring a comprehensive approach to astronaut well-being that integrates biomechanical principles with practical exercise solutions. The NGED represents the next generation of exercise capabilities for missions in space, on the Moon and Mars, with a specific focus on applications such as the LPR. METHODS AND RESULTS Data collection for NGED development was conducted with two motor-driven Beyond Power Voltra I [1] systems and a custom test structure to allow placement of the cable-based devices on the ground, at shoulder height, and overhead. The collection was performed in JSC’s Prototype Immersive Technology (PIT) Lab, utilizing an OptiTrack motion capture system and AMTI force platform, to enable detailed biomechanical analysis via OpenSim [2,3]. Motion capture data were collected for three subjects representing different body types and statures. The marker set used was an enhanced version of the full-body Plug-in Gait marker set [4], with additional markers strategically placed for the primary objective of informing exercise volume requirements. Subjects performed a series of 17 exercises, carefully selected to engage various muscle groups, including novel spaceflight exercises such as skiing (ergometer style), lateral pulldowns, wood chops, triceps extensions, and flies, with load variations ranging from 10 to 90 pounds to maintain kinematic form. This comprehensive approach allowed for a thorough evaluation of the NGED's performance across a wide range of motions and loads. The biomechanical modeling and analysis were conducted using a modified OpenSim Full Body Rajagopal Model [4,5] and also scaled to the maximum and minimum anthropometry provided in NASA-STD-3001 [6]. Volumetric convex hulls were generated based on model marker trajectories and aggregated into geometric assemblies. These can be placed in models of vehicle designs to assess fit to protect for exercise as well as to adapt NGED exercise to fit available space. Preliminary findings from the collection indicate that the NGED prototype demonstrates significant adaptability across varying user anthropometrics and exercise types. The device showed consistent performance in load-bearing exercises, with subjects able to perform exercises effectively while maintaining proper biomechanical form. CONCLUSION NGED represents a forward-looking advancement in exercise capabilities for future space missions. In the future, this system can be used to capture valuable metrics (e.g., isometric mid-thigh pull for force output measurements, assessments of postural muscle strength, overall isometric strength). Its versatility in accommodating various exercises and user physiques, coupled with the ability to provide targeted biomechanical loading, makes it a promising approach for maintaining astronaut health during long-duration missions to the Moon and Mars. Future work will focus on refining the NGED based on initial biomechanical findings, leveraging the detailed insights provided by motion capture and analysis techniques. Particular emphasis will be placed on optimizing its use within the confined spaces of a LPR and other space habitats. This work contributes significantly to NASA's goals of supporting human health and performance in deep space exploration, paving the way for sustainable long-term presence beyond Low Earth Orbit through advanced, biomechanically-informed exercise solutions.

C Wang↗

Closed loop models for analyzing the effects of simulator characteristics

The optimal control model (OCM) of the human operator is used to develop closed-loop models for analyzing the effects of (digital) simulator characteristics on predicted performance and/or workload. Two approaches are considered: the first utilizes a continuous approximation to the discrete simulation in conjunction with the standard optimal control model; the second involves a more exact discrete description of the simulator in a closed-loop multi-rate simulation in which the optimal control model 'simulates' the pilot. Both models predict that simulator characteristics can have significant effects on performance and workload.

Baron, S.↗

Model development for automatic guidance of a VTOL aircraft to a small aviation ship

This paper describes a detailed mathematical model which has been assembled to study automatic approach and landing guidance concepts to bring a VTOL aircraft onto a small aviation ship. The model is used to formulate system simulations which in turn are used to evaluate different guidance concepts. Ship motion (Sea State 5), wind-over-deck turbulence, MLS-based navigation, implicit model following flight control, lift fan V/STOL aircraft, ship and aircraft instrumentation errors, various steering laws, and appropriate environmental and human factor constraints are included in the model. Results are given to demonstrate use of the model and simulation to evaluate performance of the flight system and to choose appropriate guidance techniques for further cockpit simulator study.

Goka, T.↗

Results from Carbon Dioxide Washout Testing Using a Suited Manikin Test Apparatus with a Space Suit Ventilation Test Loop

NASA is developing an advanced portable life support system (PLSS) to meet the needs of a new NASA advanced space suit. The PLSS is one of the most critical aspects of the space suit providing the necessary oxygen, ventilation, and thermal protection for an astronaut performing a spacewalk. The ventilation subsystem in the PLSS must provide sufficient carbon dioxide (CO2) removal and ensure that the CO2 is washed away from the oronasal region of the astronaut. CO2 washout is a term used to describe the mechanism by which CO2 levels are controlled within the helmet to limit the concentration of CO2 inhaled by the astronaut. Accumulation of CO2 in the helmet or throughout the ventilation loop could cause the suited astronaut to experience hypercapnia (excessive carbon dioxide in the blood). A suited manikin test apparatus (SMTA) integrated with a space suit ventilation test loop was designed, developed, and assembled at NASA in order to experimentally validate adequate CO2 removal throughout the PLSS ventilation subsystem and to quantify CO2 washout performance under various conditions. The test results from this integrated system will be used to validate analytical models and augment human testing. This paper presents the system integration of the PLSS ventilation test loop with the SMTA including the newly developed regenerative Rapid Cycle Amine component used for CO2 removal and tidal breathing capability to emulate the human. The testing and analytical results of the integrated system are presented along with future work.

Chullen, Cinda↗

Results from Carbon Dioxide Washout Testing Using a Suited Manikin Test Apparatus with a Space Suit Ventilation Test Loop

NASA is developing an advanced portable life support system (PLSS) to meet the needs of a new NASA advanced space suit. The PLSS is one of the most critical aspects of the space suit providing the necessary oxygen, ventilation, and thermal protection for an astronaut performing a spacewalk. The ventilation subsystem in the PLSS must provide sufficient carbon dioxide (CO2) removal and ensure that the CO2 is washed away from the oronasal region of the astronaut. CO2 washout is a term used to describe the mechanism by which CO2 levels are controlled within the helmet to limit the concentration of CO2 inhaled by the astronaut. Accumulation of CO2 in the helmet or throughout the ventilation loop could cause the suited astronaut to experience hypercapnia (excessive carbon dioxide in the blood). A suited manikin test apparatus (SMTA) integrated with a space suit ventilation test loop was designed, developed, and assembled at NASA in order to experimentally validate adequate CO2 removal throughout the PLSS ventilation subsystem and to quantify CO2 washout performance under various conditions. The test results from this integrated system will be used to validate analytical models and augment human testing. This paper presents the system integration of the PLSS ventilation test loop with the SMTA including the newly developed regenerative Rapid Cycle Amine component used for CO2 removal and tidal breathing capability to emulate the human. The testing and analytical results of the integrated system are presented along with future work.

Chullen, Cinda↗

Medical Support for ISS Crewmember Training in Star City, Russia

Medical support of spaceflight training operations across international lines is a unique circumstance with potential applications to other aerospace medicine support scenarios. KBRwyle's Star City Medical Support Group (SCMSG) has fulfilled this role since the Mir-Shuttle era, with extensive experience and updates to share with the greater AsMA community. OVERVIEW: The current Soyuz training flow for assigned ISS crewmembers takes place in Star City, Russia. Soyuz training flow involves numerous activities that pose potential physical and occupational risks to crewmembers, including centrifuge runs and pressurized suit simulations at ambient and hypobaric pressures. In addition, Star City is a relatively remote location in a host nation with variable access to reliable, Western-standard medical care. For these reasons, NASA's Human Health & Performance contract allocates full-time physician support to assigned ISS crewmembers training in Star City. The Star City physician also treats minor injuries and illnesses as needed for both long- and short-term NASA support personnel traveling in the area, while working to develop and maintain relationships with local health care resources in the event of more serious medical issues that cannot be treated on-site. The specifics of this unique scope of practice will be discussed. SIGNIFICANCE: ISS crewmembers training in Star City are at potential physical and occupational risk of trauma or dysbarism during nominal Soyuz training flow, requiring medical support from an on-duty aerospace medicine specialist. This support maintains human health and performance by preserving crewmember safety and well-being for mission success; sharing information regarding this operational model may contribute to advances in other areas of international, military, and civilian operational aerospace medicine.

Chough, Natacha↗

Medical Support for ISS Crewmember Training in Star City, Russia

Medical support of spaceflight training operations across international lines is a unique circumstance with potential applications to other aerospace medicine support scenarios. KBRwyle's Star City Medical Support Group (SCMSG) has fulfilled this role since the Mir-Shuttle era, with extensive experience and updates to share with the greater AsMA community. OVERVIEW: The current Soyuz training flow for assigned ISS crewmembers takes place in Star City, Russia. Soyuz training flow involves numerous activities that pose potential physical and occupational risks to crewmembers, including centrifuge runs and pressurized suit simulations at ambient and hypobaric pressures. In addition, Star City is a relatively remote location in a host nation with variable access to reliable, Western-standard medical care. For these reasons, NASA's Human Health & Performance contract allocates full-time physician support to assigned ISS crewmembers training in Star City. The Star City physician also treats minor injuries and illnesses as needed for both long- and short-term NASA support personnel traveling in the area, while working to develop and maintain relationships with local health care resources in the event of more serious medical issues that cannot be treated on-site. The specifics of this unique scope of practice will be discussed. SIGNIFICANCE: ISS crewmembers training in Star City are at potential physical and occupational risk of trauma or dysbarism during nominal Soyuz training flow, requiring medical support from an on-duty aerospace medicine specialist. This support maintains human health and performance by preserving crewmember safety and well-being for mission success; sharing information regarding this operational model may contribute to advances in other areas of international, military, and civilian operational aerospace medicine.

Chough, Natacha↗

Numerical Investigation of Occupant Injury Risks During A Realistic Transport Aircraft Crash Conditions

Researchers at the National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC) have conducted a full-scale crash test of a Fokker F28 MK1000 aircraft to investigate the performance of transport aircraft under realistic crash conditions. This crash test was computationally recreated using finite element (FE) human body models (HBMs) to further explore potential injury risks to occupants and analyze the utilization of HBMs in the aerospace crash environment. The Global Human Body Model Consortium (GHBMC) male 50th percentile occupant detailed model (v6.0) and the Toyota Human Model for Safety (THUMS) male 50th percentile occupant model (v6.1) were selected to be used in the crash simulations. The HBMs were simulated in conditions matching those of anthropomorphic test device (ATD) experiments included within the aircraft cabin during the crash test. Seven occupant locations within the cabin were simulated utilizing each of the models. The models were positioned in a neutral upright posture with hands resting on the legs and the feet contacting the floor. Head, brain, neck, and lumbar vertebra injury metrics were calculated for all trials. Both HBM models required minor modifications to stabilize these simulations. The GHBMC model required added erosion for six parts while the THUMS model only required one in order to complete the full simulation. The THUMS model, however, required a much smaller timestep for stability and therefore took significantly more computational time. In addition the GHBMC model includes integrated instrumentation while the THUMS model requires development and implementation of instrumentation. Both models predicted 100% injury risk for lumbar vertebra fracture in all test conditions. This prediction was in family with high lumbar load values measured by the ATDs during the crash test. The THUMS model consistently predicted lower injury risks than the GHBMC model in all three other metrics varying depending on the crash pulse. Overall, the THUMS model required less modifications to allow for this study. However, the GHBMC models significantly faster run time and integrated instrumentation make it a more intuitive model for this research.

Crashworthiness↗

ResORR: A Globally Scalable and Satellite Data-Driven Algorithm for River Flow Regulation Due to Reservoir Operations

We propose a globally scalable algorithm, ResORR (Reservoir Operations driven River Regulation), to predict regulated river flow and tested it over the heavily regulated basin of the Cumberland River in the US. ResORR was found able to model regulated river flow due to upstream reservoir operations of the Cumberland River. Over a mountainous basin dominated by high rainfall, ResORR was effective in capturing extreme flooding modified by upstream hydropower dam operations. On average, ResORR improved regulated river flow simulation by more than 50% across all performance metrics when compared to a hydrologic model without a regulation module. ResORR is a timely software algorithm for understanding human regulation of surface water as satellite-estimated reservoir state is expected to improve globally with the recently launched Surface Water and Ocean Topography (SWOT) mission.

River Regulation↗

Recent Improvements and Verification of A Full Body Model in Opensim

BACKGROUND: The dynamic feasibility [1,2] criterion, that the subject’s Center of Pressure (COP) be located within the Base of Support (BOS) which outlines the feet, has aided in assessing the stability of human motion recorded on earth while performing the recorded tasks in lunar gravity or as countermeasures exercises on a vibration isolation and stabilization system in microgravity. The convex hull of the BOS on the platform under the subject’s feet was estimated using virtual markers on the feet of the scaled subject model. The COP was calculated using the ground reaction forces and moments determined from motion capture data with biomechanical modeling tools [3]. Occasionally, large-amplitude oscillatory spikes or “artifacts” were observed in the subject’s linear and angular momentum derivatives, affecting some COP data derived from motion capture. The purpose of this investigation was to assess and improve the accuracy of model scaling and BOS estimation as well as to determine the efficacy of model adjustments in mitigating artifacts influencing motion capture-derived ground reaction force and COP results. METHODS: To aid evaluation of proposed process and model updates, motion capture data were collected for two subjects during unit test and range of motion trials, lunar tasks, and countermeasures exercise motions. Markers were added to the full body Plug-in Gait marker set [4] during data collection. New markers were placed on the front, back, sides, and top of the head to improve scaling using distances between marker pairs. Medial elbow markers were added to stabilize the upper arm during OpenSim Inverse Kinematics (IK) [5]. Finally, markers were added on the outer edge of the heels and on the outside edges of the first and last toes on each foot. These additional foot markers were made available to test new automated foot scaling techniques and to calculate the error between the subject’s estimated and recorded BOS. The modified unscaled OpenSim Full Body Rajagopal Model [6,7] was adjusted using some previously investigated techniques [8] to mitigate rapid shifts in joint angles occurring during IK, as these were found to cause the spike artifacts observed in subsequent stages of analysis. Since OpenSim models use Euler angles and rotation sequences, the arm axes of rotation were adjusted, and the pelvis order of rotation was changed to minimize the likelihood of encountering “gimbal lock” during common human motion. The model clavicle, arm, elbow, wrist, pelvis, and ankle angle limits were adjusted to better accommodate the full human range of motion seen in exercise and lunar data. The shoulder joint center was calculated using a “pivoting” algorithm [9], and both shoulder joint center and upper arm markers were included during IK to provide additional shoulder stability on a case-by-case basis. The quality of IK results was assessed by three criteria: minimizing error between recorded motion capture markers and model markers, checking for reasonable rates of change in joint angles between fames (i.e., no IK artifacts), and ensuring the absence of spikes in the inertial forces and angular momentum derivatives calculated using a custom OpenSim plugin [10]. RESULTS: The additional markers placed on the subject during data collection allowed the head and feet to be scaled more accurately using distances between new marker pairs. Scaling with BOS markers placed on the subject and removing the limit on subtalar angle resulted in more accurate BOS determination. Unrealistically large changes in joint angles between frames could be reduced by including clavicle, sternum, and medial elbow markers during IK. In cases with large arm ranges of motion, results could be further improved by running IK using medial elbow and virtual shoulder joint center markers. Model adjustments significantly improved the IK results affecting COP calculation and increased the accuracy of BOS estimation.

C A Bell↗