Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE ALIGNMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

0714 - 2914 (M4-1) - Another Seyfert galaxy with aligned radio continuum and optical emission-line morphologies

Direct imaging and long-slit spectroscopic mapping of the emission-line gas in the Seyfert 2 galaxy 0714 - 2914 (M4-1, MCG - 5-18-2) are reported. The nuclear regions contain an extended (1 kpc size), high-excitation nebulosity that is well aligned with the jet-like nonthermal radio source. The profiles of Forbidden O III 5007A are asymmetric, with extended red wings to the north and west of the nucleus and extended blue wings to the south and east. This switch in the sense of asymmetry is accounted for in terms of a combination of normal rotational motions in the galaxy disk and high-velocity outflow or infall associated with the Seyfert activity.

Wilson, A. S.↗

KSpaceNavigator (KSN)

Intuitive GUI for manipulating microscope stages, allowing to align crystallographic data with stages, allowing to align crystallographic data with stage coordinates and microscope images. Simulates kinematic diffraction patterns and Kikuchi line patterns. Simulated patterns can be displayed as overlay to actually measured data, allowing manual fingerprinting and angular alignment. Crystallographic data is fed to the program in form of CIF (crystallographic information file) files, which are available from many databases and cover virtually all crystal structure ever reported in any journal. Actual goniometer scales can be linearized by lookup tables, program can be used with any microscope goniometer, double tilt and tilt-rotation type. Software requirements: Win32 platform (XP); Compiler/Version: Borland C++ Builder 5; Type of files: Executable modules; Hardware requirement: PC

Duden, Thomas↗

Centroid Detector Assembly for the AXAF-I Alignment Test System

The High Resolution Mirror Assembly (HRMA) of the Advanced X-ray Astrophysics Facility (imaging) (AXAF-I) consists of four nested paraboloids and four nested hyperboloids, all of meter-class size, and all of which are to be assembled and aligned in a special 15 meter tower at Eastman Kodak Company in Rochester, NY. The goals of the alignment are (1) to make the images of the four telescopes coincident; (2) to remove coma from each image individually; and (3) to control and determine the final position of the composite focus. This will be accomplished by the HRMA Aligment Test System (HATS) which is essentially a scanning Hartmann test system. The scanning laser source and the focal plane of the HATS are part of the Centroid Detector Assembly (CDA) which also includes processing electronics and software. In this paper we discuss the design and the measured performance of the CDA.

Glenn, Paul↗

SU-F-J-30: Application of Intra-Fractional Imaging for Pretreatment CBCT of Breath-Hold Lung SBRT

Purpose: Clinical implementation of gated lung SBRT requires tools to verify the accuracy of the target positioning on a daily basis. This is a particular challenge on Elekta linacs where the XVI imaging system does not interface directly to any commercial gating solution. In this study, we used the Elekta’s intra-fractional imaging functionality to perform the pretreatment CBCT verifications and evaluated both the image quality and gating accuracy. Methods: To use intrafraction imaging tools for pretreatment verifications, we planned a 360-degree arc with 1mmx5mm MLC opening. This beam was designed to drive the gantry during the gated CBCT data collection. A Catphan phantom was used to evaluate the image quality for the intra-fractional CBCT. A CIRS lung phantom with a 3cm sphereinsert and a moving chest plate were programmed with a simulated breathhold breathing pattern was used to check the gating accuracy. A C-Rad CatalystHD surface mapping system was used to provide the gating signal. Results: The total delivery time of the arc was 90 seconds. The uniformity and low contrast resolution for the intra-fractional CBCT was 1.5% and 3.6%, respectively. The values for the regular CBCT were 1.7% and 2.5%, respectively. The spatial resolution was 7 line-pairs/cm and the 3D spatial integrity was less than 1mm for the intra-fractional CBCT. The gated CBCT clearly demonstrated the accuracy of the gating image acquisition. Conclusion: The intra-fraction CBCT capabilities on an Elekta linac can be used to acquire pre-treatment gated images to verify the accuracy patient positioning. This imaging capability should provide for accurate patient alignments for the delivery of lung SBRT. This research was partially supported by Elekta.

60 APPLIED LIFE SCIENCES↗

AlGaN/GaN Core-Shell Nanofin Diodes on Si Substrates for Vertical GaN Electronics

We demonstrate plasma-assisted MBE selective-area growth of GaN/AlGaN core-shell structures on Si(111) as a path to vertical GaN devices. The selective-area growth enables the full vertical and uniform core-shell fin structures to be realized in a continuous growth without breaking vacuum. TEM images and EDS mapping of the core-shell structures show well-aligned crystal structure and sharp heterointerfaces. Dislocation filtering was observed in STEM imaging of the fin structure. P-N junction diodes fabricated with GaN/AlGaN core-shell structures reveal ideality factors as low as 1.5, and the reverse-bias leakage is consistent with trap-assisted space-charge-limited conduction. While practical challenges exist, including material-related leakage, growth-related challenges and optimization, this demonstration of p-n junction by this method may provide a path to vertical Superjunction device concepts in GaN and related materials.

Xiong, Juncheng [University of Notre Dame, IN (Uni↗

A Flexible Alignment Fixture for the Fabrication of Replication Mandrels

NASA uses precision diamond turning technology to fabricate replication mandrels for its X-ray Calibration Facility (XRCF) optics. The XRCF optics are tubular, and the internal surface contains a parabolic profile over the first section and a hyperbolic profile over the last. The optic is fabricated by depositing layers of gold and nickel on to the replication mandrel and then separating it from the mandrel. Since the mandrel serves as a replication form, it must contain the inverse image of the surface. The difficulty in aligning the mandrel comes from the fabrication steps which it undergoes. The mandrel is rough machined and heat treated prior to diamond turning. After diamond turning, silicon rubber separators which are undercut in radius by 3 mm (0.12 in.) are inserted between the two end caps of the mandrel to allow the plating to wrap around the ends (to prevent flaking). The mandrel is then plated with a nickel-phosphor alloy using an electroless nickel process. At this point, the separators are removed and the mandrel is reassembled for the final cut on the DTM. The mandrel is measured for profile and finish, and polished to achieve an acceptable surface finish. Wrapping the plating around the edges helps to prevent flaking, but it also destroys the alignment surfaces between the parts of the mandrel that insure that the axes of the parts are coincident. Several mandrels have been realigned by trial-and-error methods, consuming significant amounts of setup time. When the mandrel studied in this paper was reassembled, multiple efforts resulted in a minimum radial error motion of 100 microns. Since 50 microns of nickel plating was to be removed, and a minimum plating thickness of 25 microns was to remain on the part, the radial error motion had to be reduced to less than 25 microns. The mandrel was therefore not usable in its current state.

Cuttino, James F.↗

Analysis of electrically conductive adhesives in shingled solar modules by X-ray imaging techniques

The failure mechanisms of electrically conductive adhesives (ECAs) in solar modules are difficult to study since the ECA layer is not easily accessible within the module package. In this work, we present two complementary imaging modalities—X-ray radiography and X-ray microcomputed tomography (XCT)—that reveal important morphological features of the ECA within a shingled module. X-ray radiography uses single X-ray projections to provide fast and non-destructive imaging of the shingled interconnection, illuminating the alignment of the ECA relative to the busbars, the size and shape of the ECA, and the presence of voids within it. Through X-ray radiography, we observed, for example, that the average void coverage area of ECA segments reduced from 36.7% to 4.4% when an ECA was cured for 60 s prior to module lamination. XCT is a three-dimensional imaging technique that can identify regions in which the ECA makes electrical contact to busbars on cells and regions in which the ECA has cracked, among other features. XCT can also be used to image the individual metal particles within ECA, from which the metal volume fraction of an ECA was found here to be 70.4%. This is a quantity that is not often reported by ECA manufacturers but is important to ensure isotropic conduction. As X-ray projections can be performed non-destructively on full modules, the technique may be used to pinpoint ECA failures in accelerated degradation testing. XCT is complementary and is suited to forensic analysis of failing modules.

14 SOLAR ENERGY↗

Aligning Three Off-Axis Mirrors with Help of a DOE

A proposed method based on the use of a special-purpose diffractive optical element (DOE) would simplify (relative to prior methods) the alignment of three off-axis mirrors that constitute an imaging optical system. The method would exploit the fact that a DOE can be fabricated lithographically with high accuracy by electron-beam lithography in a thin film of poly(methyl methacrylate). The method would effectively transfer much of the problem of obtaining the needed accuracy from the mechanical-mirror-alignment domain to the lithographic domain. Unlike other methods that depend on specific symmetries (e.g., sphericity and/or concentricity), this method is expected to apply with equal ease and accuracy to mirrors of any configuration including aspherical, decentered mirrors. Assuming that one of the mirrors of a general three-mirror imaging optical system can serve as a reference for the alignment of the other two mirrors, such a system has 12 degrees of freedom in alignment. In the proposed method, one would use an interferometer in combination with a DOE to effect precise and relatively rapid and easy alignment of two of the mirrors with respect to each other, thus reducing the alignment task to that of the six degrees of freedom of the remaining mirror. The figure depicts a representative three-mirror off-axis imaging system, wherein the primary and tertiary mirrors (M1 and M3, respectively) are concave and the secondary mirror (M2) is convex. The DOE for aligning this system would be fabricated on the right surface of an optical flat and could be made to have either negative or positive focusing power, depending on the requirements of the specific application. The DOE could be designed to be placed at any convenient distance from M1 and M3 - again, depending on the application. The DOE would be illuminated with light coming from the left, generated by an interferometer. First, assuming the optical flat is of high quality, the plane of the DOE would be aligned perpendicular to the collimated beam by use of light reflected from the left face of the optical flat. The DOE would comprise two independent areas: one dedicated to M1, the other to M3. The portions of the collimated beam passing through those areas would be diffracted towards the corresponding mirrors. A mask, not shown in the figure, could be used to prevent light from passing through the rest of the area of the optical flat. Light rays reflected from M1 and M3 would retrace their paths through the DOE and would propagate leftward to the interferometer.

Mouroulis, Pantazis↗

Electromagnetic Detection and Real-Time DMLC Adaptation to Target Rotation During Radiotherapy

Purpose: Intrafraction rotation of more than 45 Degree-Sign and 25 Degree-Sign has been observed for lung and prostate tumors, respectively. Such rotation is not routinely adapted to during current radiotherapy, which may compromise tumor dose coverage. The aim of the study was to investigate the geometric and dosimetric performance of an electromagnetically guided real-time dynamic multileaf collimator (DMLC) tracking system to adapt to intrafractional tumor rotation. Materials/Methods: Target rotation was provided by changing the treatment couch angle. The target rotation was measured by a research Calypso system integrated with a real-time DMLC tracking system employed on a Varian linac. The geometric beam-target rotational alignment difference was measured using electronic portal images. The dosimetric accuracy was quantified using a two-dimensional ion chamber array. For each beam, the following five delivery modes were tested: 1) nonrotated target (reference); 2) fixed rotated target with tracking; 3) fixed rotated target without tracking; 4) actively rotating target with tracking; and 5) actively rotating target without tracking. Dosimetric performance of the latter four modes was measured and compared to the reference dose distribution using a 3 mm/3% {gamma}-test. Results: Geometrically, the beam-target rotational alignment difference was 0.3 Degree-Sign {+-} 0.6 Degree-Sign for fixed rotation and 0.3 Degree-Sign {+-} 1.3 Degree-Sign for active rotation. Dosimetrically, the average failure rate for the {gamma}-test for a fixed rotated target was 11% with tracking and 36% without tracking. The average failure rate for an actively rotating target was 9% with tracking and 35% without tracking. Conclusions: For the first time, real-time target rotation has been accurately detected and adapted to during radiation delivery via DMLC tracking. The beam-target rotational alignment difference was mostly within 1 Degree-Sign . Dose distributions to fixed and actively rotating targets with DMLC tracking were significantly superior to those without tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using light and X-ray scattering to untangle complex neuronal orientations and validate diffusion MRI

Disentangling human brain connectivity requires an accurate description of nerve fiber trajectories, unveiled via detailed mapping of axonal orientations. However, this is challenging because axons can cross one another on a micrometer scale. Diffusion magnetic resonance imaging (dMRI) can be used to infer axonal connectivity because it is sensitive to axonal alignment, but it has limited spatial resolution and specificity. Scattered light imaging (SLI) and small-angle X-ray scattering (SAXS) reveal axonal orientations with microscopic resolution and high specificity, respectively. Here, we apply both scattering techniques on the same samples and cross-validate them, laying the groundwork for ground-truth axonal orientation imaging and validating dMRI. We evaluate brain regions that include unidirectional and crossing fibers in human and vervet monkey brain sections. SLI and SAXS quantitatively agree regarding in-plane fiber orientations including crossings, while dMRI agrees in the majority of voxels with small discrepancies. We further use SAXS and dMRI to confirm theoretical predictions regarding SLI determination of through-plane fiber orientations. Scattered light and X-ray imaging can provide quantitative micrometer 3D fiber orientations with high resolution and specificity, facilitating detailed investigations of complex fiber architecture in the animal and human brain.

59 BASIC BIOLOGICAL SCIENCES↗

Geolocation Assessment Algorithm for CALIPSO Using Coastline Detection

Cloud-Aerosol Lidar Infrared Pathfinder Satellite Observations (CALIPSO) is a joint satellite mission between NASA and the French space agency CNES. The investigation will gather long-term, global cloud and aerosol optical and physical properties to improve climate models. The CALIPSO spacecraft is scheduled to launch in 2004 into a 98.2 inclination, 705 km circular orbit approximately 3 minutes behind the Aqua spacecraft. The payload consists of a two-wavelength polarization-sensitive lidar, and two passive imagers operating in the visible (0.645 mm) and infrared (8.7 - 12.0 mm) spectral regions. The imagers are nadir viewing and co-aligned with the lidar. Earth viewing measurements are geolocated to the Earth fixed coordinate system using satellite ephemeris, Earth rotation and geoid, and instrument pointing data. The coastline detection algorithm will assess the accuracy of the CALIPSO geolocation process by analyzing Wide Field Camera (WFC) visible ocean land boundaries. Processing space-time coincident MODIS and WFC scenes with the coastline algorithm will help verify the co-registration requirement with Moderate Resolution Imaging Spectrometer (MODIS) data. This paper quantifies the accuracy of the coastline geolocation assessment algorithm.

Currey, J. Chris↗

Impact of chopping on image quality in the SIRTF telescope

The initial Phase-A concept for the Space Infrared Telescope Facility (SIRTF), which was established in 1981, is concerned with a cryogenically cooled, 85 cm diameter, f/24 Ritchey-Chretien telescope, followed by a Multiple Instrument Chamber (MIC), containing six scientific instruments. In 1982, the Phase-A concept was reviewed with the aim to assess the technical readiness for the next phase of development. Various areas of concern were subsequently investigated in three parallel studies by industry. Two of the arising questions are considered in the present paper, taking into account the system and technology implications of achieving diffraction-limited resolution at 2 microns, and the limitations on the size of the imaging field under this condition. The conducted study takes into account an evaluation of the different methods of chopping. Attention is given to the telescope parameters, symmetric chopping, asymmetrical chopping, focus and alignment errors, the wavefront-error budget, and image quality.

Bottema, M.↗

Gaze as a biometric

Two people may analyze a visual scene in two completely different ways. Our study sought to determine whether human gaze may be used to establish the identity of an individual. To accomplish this objective we investigated the gaze pattern of twelve individuals viewing different still images with different spatial relationships. Specifically, we created 5 visual dot-pattern tests to be shown on a standard computer monitor. These tests challenged the viewer s capacity to distinguish proximity, alignment, and perceptual organization. Each test included 50 images of varying difficulty (total of 250 images). Eye-tracking data were collected from each individual while taking the tests. The eye-tracking data were converted into gaze velocities and analyzed with Hidden Markov Models to develop personalized gaze profiles. Using leave-one-out cross-validation, we observed that these personalized profiles could differentiate among the 12 users with classification accuracy ranging between 53% and 76%, depending on the test. This was statistically significantly better than random guessing (i.e., 8.3% or 1 out of 12). Classification accuracy was higher for the tests where the users average gaze velocity per case was lower. The study findings support the feasibility of using gaze as a biometric or personalized biomarker. These findings could have implications in Radiology training and the development of personalized e-learning environments.

eye tracking↗

Generic Planning Target Margin for Rectal Cancer Treatment Setup Variation

Purpose: To calculate the generic planning target margin (GPTM) for patients receiving radiation therapy (RT) for rectal cancer placed in a prone position with a customized cradle for small-bowel exclusion. Methods and Materials: A total of 25 consecutive rectal cancer patients were treated for 25 or 28 fractions in a prone position using a cradle to maximize small bowel exclusion. Treatment planning computed tomography (CT) scans were used to create orthogonally digitally reconstructed radiographs (DRRs) for portal image registration, which were compared with daily portal images from an electronic portal-imaging device (EPID). Translation values needed to align the DRRs and EPIDs were recorded for the superior to inferior (SI), right to left (RL), and anterior to posterior (AP) directions, and used to calculate the GPTM using the four-parameter model. Age, weight, and body mass index were tested compared with the setup variation using a Pearson correlation and a t test for significance. Gender versus setup variation was compared with a t test. Results: A total of 1,723 EPID images were reviewed. The GPTM was 10 mm superior, 8 mm inferior, 7 mm RL and 10 mm AP. Age and gender were unrelated to setup variation. Weight was significantly associated with systematic AP variation (p < 0.05). BMI was significantly associated with systematic SI (p < 0.05) and AP (p < 0.01) variation and random RL variation (p < 0.05). Conclusions: The GPTM for rectal cancer is asymmetric with a maximum of 10 mm in the superior, anterior and posterior dimensions. Body mass index may effect setup variation. Research using advanced treatment planning should include these margins in the planning target volume definition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-181: Magnetic Resonance Image-Guided Radiation Therapy Workflow: Initial Clinical Experience

Purpose: The aims of this work are to describe the workflow and initial clinical experience treating patients with an MRI-guided radiotherapy (MRIGRT) system. Methods: Patient treatments with a novel MR-IGRT system started at our institution in mid-January. The system consists of an on-board 0.35-T MRI, with IMRT-capable delivery via doubly-focused MLCs on three {sup 60} Co heads. In addition to volumetric MR-imaging, real-time planar imaging is performed during treatment. So far, eleven patients started treatment (six finished), ranging from bladder to lung SBRT. While the system is capable of online adaptive radiotherapy and gating, a conventional workflow was used to start, consisting of volumetric imaging for patient setup using visible tumor, evaluation of tumor motion outside of PTV on cine images, and real-time imaging. Workflow times were collected and evaluated to increase efficiency and evaluate feasibility of adding the adaptive and gating features while maintaining a reasonable patient throughput. Results: For the first month, physicians attended every fraction to provide guidance on identifying the tumor and an acceptable level of positioning and anatomical deviation. Average total treatment times (including setup) were reduced from 55 to 45 min after physician presence was no longer required and the therapists had learned to align patients based on soft-tissue imaging. Presently, the source strengths were at half maximum (7.7K Ci each), therefore beam-on times will be reduced after source replacement. Current patient load is 10 per day, with increase to 25 anticipated in the near future. Conclusion: On-board, real-time MRI-guided RT has been incorporated into clinical use. Treatment times were kept to reasonable lengths while including volumetric imaging, previews of tumor movement, and physician evaluation. Workflow and timing is being continuously evaluated to increase efficiency. In near future, adaptive and gating capabilities of the system will be implemented.

60 APPLIED LIFE SCIENCES↗

WE-B-BRD-00: MRI for Radiation Oncology

The use of MRI in radiation therapy is rapidly increasing. Applications vary from the MRI simulator, to the MRI fused with CT, and to the integrated MRI+RT system. Compared with the standard MRI QA, a broader scope of QA features has to be defined in order to maximize the benefits of using MRI in radiation therapy. These QA features include geometric fidelity, image registration, motion management, cross-system alignment, and hardware interference. Advanced MRI techniques require a specific type of QA, as they are being widely used in radiation therapy planning, dose calculations, post-implant dosimetry, and prognoses. A vigorous and adaptive QA program is crucial to defining the responsibility of the entire radiation therapy group and detecting deviations from the performance of high-quality treatment. As a drastic departure from CT simulation, MRI simulation requires changes in the work flow of treatment planning and image guidance. MRI guided radiotherapy platforms are being developed and commercialized to take the advantage of the advance in knowledge, technology and clinical experience. This symposium will from an educational perspective discuss the scope and specific issues related to MRI guided radiotherapy. Learning Objectives: Understand the difference between a standard and a radiotherapy-specific MRI QA program. Understand the effects of MRI artifacts (geometric distortion and motion) on radiotherapy. Understand advanced MRI techniques (ultrashort echo, fast MRI including dynamic MRI and 4DMRI, diffusion, perfusion, and MRS) and related QA. Understand the methods to prepare MRI for treatment planning (electron density assignment, multimodality image registration, segmentation and motion management). Current status of MRI guided treatment platforms. Dr. Jihong Wang has a research grant with Elekta-MRL project. Dr. Ke Sheng receives research grants from Varian Medical systems.

60 APPLIED LIFE SCIENCES↗

WE-B-BRD-01: MR-LINAC

The use of MRI in radiation therapy is rapidly increasing. Applications vary from the MRI simulator, to the MRI fused with CT, and to the integrated MRI+RT system. Compared with the standard MRI QA, a broader scope of QA features has to be defined in order to maximize the benefits of using MRI in radiation therapy. These QA features include geometric fidelity, image registration, motion management, cross-system alignment, and hardware interference. Advanced MRI techniques require a specific type of QA, as they are being widely used in radiation therapy planning, dose calculations, post-implant dosimetry, and prognoses. A vigorous and adaptive QA program is crucial to defining the responsibility of the entire radiation therapy group and detecting deviations from the performance of high-quality treatment. As a drastic departure from CT simulation, MRI simulation requires changes in the work flow of treatment planning and image guidance. MRI guided radiotherapy platforms are being developed and commercialized to take the advantage of the advance in knowledge, technology and clinical experience. This symposium will from an educational perspective discuss the scope and specific issues related to MRI guided radiotherapy. Learning Objectives: Understand the difference between a standard and a radiotherapy-specific MRI QA program. Understand the effects of MRI artifacts (geometric distortion and motion) on radiotherapy. Understand advanced MRI techniques (ultrashort echo, fast MRI including dynamic MRI and 4DMRI, diffusion, perfusion, and MRS) and related QA. Understand the methods to prepare MRI for treatment planning (electron density assignment, multimodality image registration, segmentation and motion management). Current status of MRI guided treatment platforms. Dr. Jihong Wang has a research grant with Elekta-MRL project. Dr. Ke Sheng receives research grants from Varian Medical systems.

60 APPLIED LIFE SCIENCES↗

WE-B-BRD-02: MR Simulation for Radiation Therapy

The use of MRI in radiation therapy is rapidly increasing. Applications vary from the MRI simulator, to the MRI fused with CT, and to the integrated MRI+RT system. Compared with the standard MRI QA, a broader scope of QA features has to be defined in order to maximize the benefits of using MRI in radiation therapy. These QA features include geometric fidelity, image registration, motion management, cross-system alignment, and hardware interference. Advanced MRI techniques require a specific type of QA, as they are being widely used in radiation therapy planning, dose calculations, post-implant dosimetry, and prognoses. A vigorous and adaptive QA program is crucial to defining the responsibility of the entire radiation therapy group and detecting deviations from the performance of high-quality treatment. As a drastic departure from CT simulation, MRI simulation requires changes in the work flow of treatment planning and image guidance. MRI guided radiotherapy platforms are being developed and commercialized to take the advantage of the advance in knowledge, technology and clinical experience. This symposium will from an educational perspective discuss the scope and specific issues related to MRI guided radiotherapy. Learning Objectives: Understand the difference between a standard and a radiotherapy-specific MRI QA program. Understand the effects of MRI artifacts (geometric distortion and motion) on radiotherapy. Understand advanced MRI techniques (ultrashort echo, fast MRI including dynamic MRI and 4DMRI, diffusion, perfusion, and MRS) and related QA. Understand the methods to prepare MRI for treatment planning (electron density assignment, multimodality image registration, segmentation and motion management). Current status of MRI guided treatment platforms. Dr. Jihong Wang has a research grant with Elekta-MRL project. Dr. Ke Sheng receives research grants from Varian Medical systems.

60 APPLIED LIFE SCIENCES↗