Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Evaluating Cryo–TEM Reconstruction Accuracy of Self–Assembled Polymer Nanostructures

Cryogenic transmission electron microscopy (cryo–TEM) combined with single particle analysis (SPA) is an emerging imaging approach for soft materials. However, the accuracy of SPA–reconstructed nanostructures, particularly those formed by synthetic polymers, remains uncertain due to potential packing heterogeneity of the nanostructures. In this study, the combination of molecular dynamics (MD) simulations and image simulations is utilized to validate the accuracy of cryo–TEM 3D reconstructions of self–assembled polypeptoid fibril nanostructures. Using CryoSPARC software, image simulations, 2D classifications, ab initio reconstructions, and homogenous refinements are performed. By comparing the results with atomic models, the recovery of molecular details is assessed, heterogeneous structures are identified, and the influence of extraction location on the reconstructions is evaluated. In conclusion, these findings confirm the fidelity of single particle analysis in accurately resolving complex structural characteristics and heterogeneous structures, exhibiting its potential as a valuable tool for detailed structural analysis of synthetic polymers and soft materials.

36 MATERIALS SCIENCE↗

A Fast Visible-Infrared Imaging Radiometer Suite Simulator for Cloudy Atmopheres

A fast instrument simulator is developed to simulate the observations made in cloudy atmospheres by the Visible Infrared Imaging Radiometer Suite (VIIRS). The correlated k-distribution (CKD) technique is used to compute the transmissivity of absorbing atmospheric gases. The bulk scattering properties of ice clouds used in this study are based on the ice model used for the MODIS Collection 6 ice cloud products. Two fast radiative transfer models based on pre-computed ice cloud look-up-tables are used for the VIIRS solar and infrared channels. The accuracy and efficiency of the fast simulator are quantify in comparison with a combination of the rigorous line-by-line (LBLRTM) and discrete ordinate radiative transfer (DISORT) models. Relative errors are less than 2 for simulated TOA reflectances for the solar channels and the brightness temperature differences for the infrared channels are less than 0.2 K. The simulator is over three orders of magnitude faster than the benchmark LBLRTM+DISORT model. Furthermore, the cloudy atmosphere reflectances and brightness temperatures from the fast VIIRS simulator compare favorably with those from VIIRS observations.

VIIRS Instrument Simulator↗

SU-E-J-125: A Novel IMRT Planning Technique to Spare Sacral Bone Marrow in Pelvic Cancer Patients

Purpose: Develop an IMRT planning technique that can preferentially spare sacral bone marrow for pelvic cancer patients. Methods: Six pelvic cancer patients (two each with anal, cervical, and rectal cancer) were enrolled in an IRB approved protocol to obtain FLT PET images at simulation, during, and post chemoradiation therapy. Initially, conventional IMRT plans were created to maintain target coverage and reduce dose to OARs such as bladder, bowel, rectum, and femoral heads. Simulation FLT PET images were used to create IMRT plans to spare bone marrow identified as regions with SUV of 2 or greater (IMRT-BMS) within the pelvic bones from top of L3 to 5mm below the greater trochanter without compromising PTV coverage or OAR sparing when compared to the initial IMRT plan. IMRT-BMS plans used 8–10 beam angles that surrounded the subject. These plans were used for treatment. Retrospectively, the same simulation FLT PET images were used to create IMRT plans that spared bone marrow located in the sacral pelvic bone region (IMRT-FAN) also without compromising PTV coverage or OAR sparing. IMRT-FAN plans used 16 beam angles every 12° anteriorly from 90° – 270°. Optimization objectives for the sacral bone marrow avoidance region were weighted to reduce ≥V10. Results: IMRT-FAN reduced dose to the sacral bone marrow for all six subjects. The average V5, V10, V20, and V30 differences from the IMRT-BMS plan were −2.2 ± 1.7%, −11.4 ± 3.6%, −17.6 ± 5.1%, and −19.1 ± 8.1% respectively. Average PTV coverage change was 0.5% ± 0.8% from the conventional IMRT plan. Conclusion: An IMRT planning technique that uses beams from the anterior and lateral directions reduced the volume of sacral bone marrow that receives ≤10Gy while maintaining PTV coverage and OAR sparing. Additionally, the volume of sacral bone marrow that received 20 or 30 Gy was also reduced.

60 APPLIED LIFE SCIENCES↗

WE-AB-303-03: A Scheme for Real-Time, Marker-Less and Low-Dose Tumor Tracking Using Scattering Imaging: Monte Carlo Simulation Study

Purpose: In-treatment tumor localization is critical for the management of tumor motion in lung cancer radiotherapy. Conventional tumor-tracking methods using a kV or MV x-ray projection has limited contrast. To facilitate real-time, marker-less and low-dose in-treatment image tumor tracking, we propose a novel scheme using Compton scatter imaging. This study reports Monte Carlo (MC) simulations on this scheme for the purpose of proof-of-principle. Methods: A slit x-ray beam along the patient superior-inferior (SI) direction is directed to the patient, intersecting the patient lung at a 2D plane containing majority part of the tumor motion trajectory. X-ray photons are scattered due to Compton effect from this plane, which are spatially collimated by, e.g., a pinhole, on one side of the plane and then captured by a detector behind it. The captured image, after correcting for x-ray attenuation and scatter angle variation, reflects the electron density, which allows visualization of the instantaneous anatomy on this plane. We performed MC studies on a phantom and a patient case for the initial test of this proposed method. Results: In the phantom case, the contrast-resolution calculated using tumor/lung as foreground/background for kV fluoroscopy, cone-beam CT, and scattering image were 0.0625, 0.6993, and 0.5290, respectively. In the patient case, tumor motion can be clearly observed in the scatter images. Compared to fluoroscopy, scattering imaging also significantly reduced imaging dose because of its narrower beam design. Conclusion: MC simulation studies demonstrated the potential of the proposed scheme in terms of capturing the instantaneous anatomy of a patient on a 2D plane. Clear visualization of the tumor will probably facilitate ‘marker-less’ and ‘real-time’ tumor tracking with low imaging dose. NIH (1R01CA154747-01, 1R21CA178787-01A1 and 1R21EB017978-01A1)

60 APPLIED LIFE SCIENCES↗

Simulation of Properties of Images with Atomic Resolution in a Scanning Probe Microscope

A method for simulation of images in a scanning probe microscope (SPM) using simultaneous wavelet transform and median filtering is proposed. The wavelet transform with the fourth-order Daubechies kernel is used. Such a transform makes it possible to select details of different scales in the SPM image and, hence, study fractal properties of surfaces. Simulation is used to show that ultrahigh (atomic) resolution is possible in SPM provided that the size of the contact region in the probe–sample system is significantly greater than atomic size and the lattice atoms are randomly distributed. Contrast inversion in the SPM images in the multiscan mode is interpreted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Construction and analysis of simulated Venera and Magellan images of Venus

The 1-3 km resolution Venera 15 and 16 images of Venus and the expected 120-300 m resolution Magellan mission image data are presently simulated through a digital processing of Seasat radar images covering a desert dune complex in the Gran Desierto of Sonora, accreted terranes in the central interior of Alaska, and the Appalachian Valley and Ridge Province. The simulations suggest that the nature and extent of terrain modification on Venus by such exogenic processes as atmosphere-surface weathering, erosion, and deposition, will remain uncertain, since the length scale of features indicative of such processes may be too small to be discerned from Venera data; Magellan data may provide this critical fine-scale morphological data, however, and thereby allow the testing of the two competing resurfacing scenarios.

Arvidson, R. E.↗

An X-ray method for detecting substructure in galaxy clusters - Application to Perseus, A2256, Centaurus, Coma, and Sersic 40/6

We use the moments of the X-ray surface brightness distribution to constrain the dynamical state of a galaxy cluster. Using X-ray observations from the Einstein Observatory IPC, we measure the first moment FM, the ellipsoidal orientation angle, and the axial ratio at a sequence of radii in the cluster. We argue that a significant variation in the image centroid FM as a function of radius is evidence for a nonequilibrium feature in the intracluster medium (ICM) density distribution. In simple terms, centroid shifts indicate that the center of mass of the ICM varies with radius. This variation is a tracer of continuing dynamical evolution. For each cluster, we evaluate the significance of variations in the centroid of the IPC image by computing the same statistics on an ensemble of simulated cluster images. In producing these simulated images we include X-ray point source emission, telescope vignetting, Poisson noise, and characteristics of the IPC. Application of this new method to five Abell clusters reveals that the core of each one has significant substructure. In addition, we find significant variations in the orientation angle and the axial ratio for several of the clusters.

Mohr, Joseph J.↗

Comparisons Between NO PLIF Imaging and CFD Simulations of Mixing Flowfields for High-Speed Fuel Injectors

The current work compares experimentally and computationally obtained nitric oxide (NO) planar laser induced fluorescence (PLIF) images of the mixing flowfields for three types of high-speed fuel injectors: a strut, a ramp, and a rectangular flushwall. These injection devices, which exhibited promising mixing performance at lower flight Mach numbers, are currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. The EIMP aims to investigate scramjet fuel injection and mixing physics, and improve the understanding of underlying physical processes relevant to flight Mach numbers greater than eight. In the experiments, conducted in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF), the injectors are placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number air flow at the entrance of a scramjet combustor. Helium is used as an inert substitute for hydrogen fuel. Both schlieren and PLIF techniques are applied to obtain mixing flowfield flow visualizations. The experimental PLIF is obtained by using a UV laser sheet to interrogate a plane of the flow by exciting fluorescence from the NO molecules, which are present in the AHSTF air. Consequently, the absence of signal in the resulting PLIF images is an indication of pure helium (fuel). The computational PLIF is obtained by applying a fluorescence model for NO to the results of the Reynolds-averaged simulations (RAS) of the mixing flow field carried out using the VULCAN-CFD solver. This approach is required because the PLIF signal is a nonlinear function of not only NO concentration, but also pressure, temperature, and the flow velocity. This complexity allows additional flow features to be identified and compared with those obtained from the computational fluid dynamics (CFD) simulations, however, such comparisons are only semiquantitative. Three-dimensional image reconstruction, similar to that used in magnetic resonance imaging, is also used to obtain images in the streamwise and spanwise planes from select cross-stream PLIF plane data. Synthetic schlieren is also computed from the RAS data. Good agreement between the experimental and computational results provides increased confidence in the CFD simulations for investigations of injector performance.

Drozda, Tomasz G.↗

Comparisons Between NO PLIF Imaging and CFD Simulations of Mixing Flowfields for High-Speed Fuel Injectors

The current work compares experimentally and computationally obtained nitric oxide (NO) planar laser-induced fluorescence (PLIF) images of the mixing flowfields for three types of high-speed fuel injectors: a strut, a ramp, and a rectangular flushwall. These injection devices, which exhibited promising mixing performance at lower flight Mach numbers, are currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. The EIMP aims to investigate scramjet fuel injection and mixing physics, and improve the understanding of underlying physical processes relevant to flight Mach numbers greater than eight. In the experiments conducted in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF), the injectors are placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number air flow at the entrance of a scramjet combustor. Helium is used as an inert substitute for hydrogen fuel. Both schlieren and PLIF techniques are applied to obtain mixing flowfield flow visualizations. The experimental PLIF is obtained by using a UV laser sheet to interrogate a plane of the flow by exciting fluorescence from the NO molecules that are present in the AHSTF air. Consequently, the absence of signal in the resulting PLIF images is an indication of pure helium (fuel). The computational PLIF is obtained by applying a fluorescence model for NO to the results of the Reynolds-averaged simulations (RAS) of the mixing flowfield carried out using the VULCAN-CFD solver. This approach is required because the PLIF signal is a nonlinear function of not only NO concentration, but also pressure, temperature, and the flow velocity. This complexity allows additional flow features to be identified and compared with those obtained from the computational fluid dynamics (CFD) simulations, however, such comparisons are only semiquantitative. Three-dimensional image reconstruction, similar to that used in magnetic resonance imaging, is also used to obtain images in the streamwise and spanwise planes from select cross-stream PLIF plane data. Synthetic schlieren is also computed from the RAS data. Good agreement between the experimental and computational results provides increased confidence in the CFD simulations for investigations of injector performance.

PLIF↗

Comparisons Between NO PLIF Imaging and CFD Simulations of Mixing Flowfields for High-Speed Fuel Injectors

The current work compares experimentally and computationally obtained nitric oxide (NO) planar laser-induced fluorescence (PLIF) images of the mixing flowfields for three types of high-speed fuel injectors: a strut, a ramp, and a rectangular flushwall. These injection devices, which exhibited promising mixing performance at lower flight Mach numbers, are currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. The EIMP aims to investigate scramjet fuel injection and mixing physics, and improve the understanding of underlying physical processes relevant to flight Mach numbers greater than eight. In the experiments conducted in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF), the injectors are placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number air flow at the entrance of a scramjet combustor. Helium is used as an inert substitute for hydrogen fuel. Both schlieren and PLIF techniques are applied to obtain mixing flowfield flow visualizations. The experimental PLIF is obtained by using a UV laser sheet to interrogate a plane of the flow by exciting fluorescence from the NO molecules that are present in the AHSTF air. Consequently, the absence of signal in the resulting PLIF images is an indication of pure helium (fuel). The computational PLIF is obtained by applying a fluorescence model for NO to the results of the Reynolds-averaged simulations (RAS) of the mixing flowfield carried out using the VULCAN-CFD solver. This approach is required because the PLIF signal is a nonlinear function of not only NO concentration, but also pressure, temperature, and the flow velocity. This complexity allows additional flow features to be identified and compared with those obtained from the computational fluid dynamics (CFD) simulations, however, such comparisons are only semiquantitative. Three-dimensional image reconstruction, similar to that used in magnetic resonance imaging, is also used to obtain images in the streamwise and spanwise planes from select cross-stream PLIF plane data. Synthetic schlieren is also computed from the RAS data. Good agreement between the experimental and computational results provides increased confidence in the CFD simulations for investigations of injector performance.

PLIF↗

Comparisons Between NO PLIF Imaging and CFD Simulations of Mixing Flowfields for High-Speed Fuel Injectors

The current work compares experimentally and computationally obtained nitric oxide (NO) planar laser-induced fluorescence (PLIF) images of the mixing flowfields for three types of high-speed fuel injectors: a strut, a ramp, and a rectangular flush-wall. These injection devices, which exhibited promising mixing performance at lower flight Mach numbers, are currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. The EIMP aims to investigate scramjet fuel injection and mixing physics, and improve the understanding of underlying physical processes relevant to flight Mach numbers greater than eight. In the experiments, conducted in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF), the injectors are placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number air flow at the entrance of a scramjet combustor. Helium is used as an inert substitute for hydrogen fuel. The PLIF is obtained by using a tunable laser to excite the NO, which is present in the AHSTF air as a direct result of arc-heating. Consequently, the absence of signal is an indication of pure helium (fuel). The PLIF images computed from the computational fluid dynamics (CFD) simulations are obtained by combining a fluorescence model for NO with the Reynolds-Averaged Simulation results carried out using the VULCAN-CFD solver to obtain a computational equivalent of the experimentally measured PLIF signal. The measured NO PLIF signal is mainly a function of NO concentration allowing for semi-quantitative comparisons between the CFD and the experiments. The PLIF signal intensity is also sensitive to pressure and temperature variations in the flow, allowing additional flow features to be identified and compared with the CFD. Good agreement between the PLIF and the CFD results provides increased confidence in the CFD simulations for investigations of injector performance.

Drozda, Tomasz, G.↗

Comparison of Repositioning Accuracy of Two Commercially Available Immobilization Systems for Treatment of Head-and-Neck Tumors Using Simulation Computed Tomography Imaging

Purpose: To compare the setup accuracy, comfort level, and setup time of two immobilization systems used in head-and-neck radiotherapy. Methods and Materials: Between February 2004 and January 2005, 21 patients undergoing radiotherapy for head-and-neck tumors were assigned to one of two immobilization devices: a standard thermoplastic head-and-shoulder mask fixed to a carbon fiber base (Type S) or a thermoplastic head mask fixed to the Accufix cantilever board equipped with the shoulder depression system. All patients underwent planning computed tomography (CT) followed by repeated control CT under simulation conditions during the course of therapy. The CT images were subsequently co-registered and setup accuracy was examined by recording displacement in the three cartesian planes at six anatomic landmarks and calculating the three-dimensional vector errors. In addition, the setup time and comfort of the two systems were compared. Results: A total of 64 CT data sets were analyzed. No difference was found in the cartesian total displacement errors or total vector displacement errors between the two populations at any landmark considered. A trend was noted toward a smaller mean systemic error for the upper landmarks favoring the Accufix system. No difference was noted in the setup time or comfort level between the two systems. Conclusion: No significant difference in the three-dimensional setup accuracy was identified between the two immobilization systems compared. The data from this study reassure us that our technique provides accurate patient immobilization, allowing us to limit our planning target volume to <4 mm when treating head-and-neck tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-195: On the Performance of Four Dual Energy CT Formalisms for Extracting Proton Stopping Powers

Purpose: Dual energy CT can predict stopping power ratios (SPR) for ion therapy treatment planning. Several approaches have been proposed recently, however accuracy and practicability in a clinical workflow are unaddressed. The aim of this work is to provide a fair comparison of available approaches in a human-like phantom to find the optimal method for tissue characterization in a clinical situation. Methods: The SPR determination accuracy is investigated using simulated DECT images. A virtual human-like phantom is created containing 14 different standard human tissues. SECT (120 kV) and DECT images (100 kV and 140 kV Sn) are simulated using the software ImaSim. The single energy CT (SECT) stoichiometric calibration method and four recently published calibration-based DECT methods are implemented and used to predict the SPRs from simulated images. The difference between SPR predictions and theoretical SPR are compared pixelwize. Mean, standard deviation and skewness of the SPR difference distributions are used as measures for bias, dispersion and symmetry. Results: The average SPR differences and standard deviations are (0.22 ± 1.27)% for SECT, and A) (−0.26 ± 1.30)%, B) (0.08 ± 1.12)%, C) (0.06 ± 1.15)% and D) (−0.05 ± 1.05)% for the four DECT methods. While SPR prediction using SECT is showing a systematic error on SPR, the DECT methods B, C and D are unbiased. The skewness of the SECT distribution is 0.57%, and A) −0.19%, B) −0.56%, C) −0.29% and D) −0.07% for DECT methods respectively. Conclusion: The here presented DECT methods B, C and D outperform the commonly used SECT stoichiometric calibration. These methods predict SPR accurately without a bias and within ± 1.2% (68th percentile). This indicates that DECT potentially improves accuracy of range predictions in proton therapy. A validation of these findings using clinical CT images of real tissues is necessary.

60 APPLIED LIFE SCIENCES↗

A Dataset of CFD Simulated Industrial Furnace Images for Conditional Automatic Generation with GANs

The steel industry is constantly looking for ways to automate processes and improve efficiency. A standard practice in industry is to simulate how complex systems will operate before they are actually used. Some complex systems, including steel industry processes such as blast furnaces, require complex physics-based simulations utilizing computational fluid dynamics (CFD). These CFD physics-based simulations are very accurate but can take significant time and computational resources to process, resulting in challenges for the implementation of the models in real-world operational environments. In recent years, deep learning (DL) has been considered as a substitute for these CFD models. DL models can be trained on validated CFD simulation data and then used for industrial process inference. Previous DL-based solutions have made great contributions for industrial automation but are currently missing the additional visualization component that CFD simulations also provide. In this paper, we propose a dataset for simple DL generative approaches that can help to address this issue. The dataset and methodology under development to approach this prediction are discussed in this work.

Calix, Ricardo↗

Resolution Versus Error for Computational Electron Microscopy

Images that are collected via scanning transmission electron microscopy (STEM) can be undersampled to avoid damage to the specimen while maintaining resolution [1, 2]. We have used BPFA to impute missing data and reduce noise [3]. The reconstruction is typically evaluated using the peak signal-to-noise ratio (PSNR). This measure is too conservative for STEM images and we propose that the Fourier ring correlation (FRC) is used instead to evaluate the reconstruction. We are not concerned with exact reconstruction of the truth image, and therefore PSNR is a conservative estimation of the quality of the reconstruction. Instead, we are concerned with the visual resolution of the image and whether atoms can be distinguished. We have evaluated the reconstruction of a simulated STEM image using the FRC and compared the results with the PSNR measurements. The FRC captures the resolution of the image and is not affected by a large MSE if the atom peaks are still distinguishable. The noisy and reconstructed images are shown in Figure 1. The simulated STEM image was sampled at 100%, 80%, 40%, and 20% of the original pixels to simulate an undersampled scan. The reconstruction was done using BPFA with a patch size of 10 x 10 and no overlapping patches. Not having overlapping patches produces inferior results but they are still acceptable. The dictionary size is 64 and 30 iterations were completed during each reconstruction. The 100% image was denoised instead of reconstructed. Poisson noise was applied to the simulated image with λ values of 500, 50, and 5 to simulate lower imaging dose. The original simulated STEM image was also included in our calculations and was generated using a dose of 1000. The simulated STEM image is 100 by 100 pixels and has essentially no high frequency components. The image reconstruction tends to smooth the data, also resulting in no high frequency components. This causes the FRC of the two images to be large at higher resolutions and may be misleading. For this reason, the BPFA has no overlap to avoid excessive smoothing. Moreover, the resolution of the simulated image is approximately 9.2 (1/nm), so we only look that far in the frequency domain when performing FRC. If the FRC curve does not crossover the threshold, a resolution value of 9.2 is used. We emphasize that our reported results are conservative. The FRC and PSNR values using the ground truth and the reconstructed images are shown in Tables 1 and 2. The left side show the metrics without using BPFA (missing pixels) and the right side show the metrics after using BPFA. When we did not use BPFA, the Fourier transform was estimated [4]. Some threshold curves have been studied [5], but they are derived for additive noise models. Since we have a Poisson noise model, we have used the more conservative threshold of 0.5 for our calculations. Ten images were used to construct each cell of tables in the form of the mean of the metric plus or minus its standard deviation. As expected, the PSNR dies off much quicker than the FRC values for the same image. For the 100% and 80% sampled versions of the truth image, the resolution only dies off when the dose is 5. However, the PSNR dies off rapidly as the dose is reduced. For the 1000, 500, and 50 dose images, the FRC is the maximum, or close, until we undersample at 20%. The PSNR for these values tapers down as we get into the bottom right hand corner of the table, even though the resolution remains high. Overall, we find that undersampled images can be reconstructed to acceptable resolution even when the dose per pixel is also reduced[6]. References: [1]A Stevens, H Yang, L Carin et al. Microscopy 63(1), (2014), pp. 41. [2]A Stevens, L Kovarik, P Abellan et al. Advanced Structural and Chemical Imaging 1(1), (2015), pp. 1. [3]M Zhou, H Chen, J Paisley et al. Image Processing, IEEE Transactions on 21(1), (2012), pp. 130. [4]V. Y. Liepin’sh. Automatic control and computer sciences 30(3), (1996), pp. 20.

Luzi, Lorenzo↗

NEW DEVELOPMENTS IN DIGITAL X-RAY TECHNIQUES: A SIMULATION TOOL FOR SCATTERING IMAGING

This paper focus mainly on a simulation tool used to compute X-ray imaging technique and the last developments with the calculation of the scattering. It allows evaluating the scattered contribution on a transmission detector but also simulating scattering technique as Compton or Rayleigh tomography. A major interest of the Compton scattering technique is that the experimental device is located on one side of the object, and thus, an image can be acquired even if we can not access to the other side of the object.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulated real time image guided intrafraction tracking-delivery for hypofractionated prostate IMRT

Hypofractionated stereotactic body radiotherapy (SBRT) has been tested for prostate cancer radiotherapy. This study aims to investigate the dosimetric effects of intrafraction prostate motion on the target and the normal structures for SBRT. For prostate cancer patients treated with an image-tracking CyberKnife system, the intrafraction prostate movements were recorded during 50-70 min treatment time. Based on the recorded intrafraction prostate movements, treatment plans were created for these cases using intensity modulated beams while scaling the average time patterns from the CyberKnife treatment to simulate hypofractionated intensity modulated radiotherapy (IMRT) delivery. The effect of delivery time on the intrafraction organ motion was investigated. For a nominal single fraction delivery of 9.5 Gy with IMRT, we found that the dosimetric effect of the intrafraction prostate movement is case dependent. For most cases, the dose volume histograms exhibited very small changes from the treatment plans that assumed no intrafractional prostate motion when the maximum intrafraction movements were within {+-}5 mm. However, when sporadic prostate movements greater than 5 mm were present in any one direction, significant changes were found. For example, the V{sub 100%} for the prostate could be reduced by more than 10% to less than 85% of the prostate volume coverage. If these large movements could be excluded by some active correction strategies, then the average V{sub 100%} for the simulated plan could be restored to within approximately 2% of the ideal treatment plans. On average, the sporadic intrafraction motion has less dosimetric impact on the prolonged treatment delivery versus fast treatment delivery. For example, the average V{sub 100%} for the clinical target volume was reduced from the original 95.1% to 92.1{+-} 3.7% for prolonged treatment, and to 91.3{+-}5.4% when the treatment time was shortened by 50%. Due to the observed large sporadic prostate motions, we conclude that an on-line target motion monitoring and correction strategy is necessary to implement hypofractionated SBRT with intensity modulated beams for prostate cancer treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗