Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inlet diffusers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

LANDSAT imagery of the Venetian Lagoon: A multitemporal analysis

The use of LANDSAT multispectral scanner images from 1975 to 1979 to determine pollution dispersion in the central basin of the lagoon under varying tidal conditions is described. Images taken during the late spring and representing both short and long range tidal dynamics were processed for partial haze removal and removal of residual striping. Selected spectral bands were correlated to different types of turbid water. The multitemporal data was calibrated, classified considering sea truth data, and evaluated. The classification differentiated tide diffusion, algae belts, and industrial, agricultural, and urban turbidity distributions. Pollution concentration is derived during the short time interval between inflow and outflow and from the distance between the two lagoon inlets and the industrial zones. Increasing pollution of the lagoon is indicated.

Alberotanza, L.↗

Active unsteady aerodynamic suppression of rotating stall in an incompressible flow centrifugal compressor with vaned diffuser

A mathematical model is developed to analyze the suppression of rotating stall in an incompressible flow centrifugal compressor with a vaned diffuser, thereby addressing the important need for centrifugal compressor rotating stall and surge control. In this model, the precursor to to instability is a weak rotating potential velocity perturbation in the inlet flow field that eventually develops into a finite disturbance. To suppress the growth of this potential disturbance, a rotating control vortical velocity disturbance is introduced into the impeller inlet flow. The effectiveness of this control is analyzed by matching the perturbation pressure in the compressor inlet and exit flow fields with a model for the unsteady behavior of the compressor. To demonstrate instability control, this model is then used to predict the control effectiveness for centrifugal compressor geometries based on a low speed research centrifugal compressor. These results indicate that reductions of 10 to 15 percent in the mean inlet flow coefficient at instability are possible with control waveforms of half the magnitude of the total disturbance at the inlet.

Lawless, Patrick B.↗

Conceptual Design of a Two Spool Compressor for the NASA Large Civil Tilt Rotor Engine

This paper focuses on the conceptual design of a two spool compressor for the NASA Large Civil Tilt Rotor engine, which has a design-point pressure ratio goal of 30:1 and an inlet weight flow of 30.0 lbm/sec. The compressor notional design requirements of pressure ratio and low-pressure compressor (LPC) and high pressure ratio compressor (HPC) work split were based on a previous engine system study to meet the mission requirements of the NASA Subsonic Rotary Wing Projects Large Civil Tilt Rotor vehicle concept. Three mean line compressor design and flow analysis codes were utilized for the conceptual design of a two-spool compressor configuration. This study assesses the technical challenges of design for various compressor configuration options to meet the given engine cycle results. In the process of sizing, the technical challenges of the compressor became apparent as the aerodynamics were taken into consideration. Mechanical constraints were considered in the study such as maximum rotor tip speeds and conceptual sizing of rotor disks and shafts. The rotor clearance-to-span ratio in the last stage of the LPC is 1.5% and in the last stage of the HPC is 2.8%. Four different configurations to meet the HPC requirements were studied, ranging from a single stage centrifugal, two axi-centrifugals, and all axial stages. Challenges of the HPC design include the high temperature (1,560deg R) at the exit which could limit the maximum allowable peripheral tip speed for centrifugals, and is dependent on material selection. The mean line design also resulted in the definition of the flow path geometry of the axial and centrifugal compressor stages, rotor and stator vane angles, velocity components, and flow conditions at the leading and trailing edges of each blade row at the hub, mean and tip. A mean line compressor analysis code was used to estimate the compressor performance maps at off-design speeds and to determine the required variable geometry reset schedules of the inlet guide vane and variable stators that would result in the transonic stages being aerodynamically matched with high efficiency and acceptable stall margins based on user specified maximum levels of rotor diffusion factor and relative velocity ratio.

Veres, Joseph P.↗

Experimental Investigation of a High Subsonic Mach Number Turbine Having Low Rotor Suction-surface Diffusion

The quasi-three-dimensional method for the aerodynamic design of both stator and rotor blades is presented for a turbine having high weight flow and high specific work output. The turbine was designed for a relative critical velocity ratio of 0.82 at the rotor hub inlet. At the condition of equivalent design work output and blade speed, the efficiency based on the overall actual total-pressure ratio was 0.875, which is almost at high as those obtained for conservatively designed turbines.

Hauser, Cavour H↗

Some design considerations for supersonic cruise mixed compression inlets

A mixed compression inlet designed for supersonic cruise has very demanding requirements for high total pressure recovery and low bleed and cowl drag. However, since the optimum inlet for supersonic cruise performance may have other undesirable characteristics, it is necessary to establish trade-offs between inlet performance and other inlet characteristics. Some of these trade-offs between the amount of internal compression, aerodynamic performance and angle-of-attack tolerance are reviewed. Techniques for analysis of boundary layer control and subsonic diffuser flow are discussed.

Bowditch, D. N.↗

Calculations of particle-laden flows by second-moment closures

A differential second-moment closure is applied to calculate nonswirling turbulent particle-laden jet flow. The closure is effected by extending constant-density single-phase turbulence models to the continuous (carrier) phase of two-phase flow. The dispersed (discrete) phase is treated by stochastic-Lagrangian technique. To reduce the effects of numerical (false) diffusion on the predicted results, a higher order differencing scheme, namely the flux-spline, is employed. In addition, an experimental study is conducted to provide data of good quality, especially near the inlet, for model assessment. The experiment consists of a confined coaxial jet flow of air with glass beads. The beads' diameter is 105 microns and is injected from the inner jet with a mass loading ratio of 0.9. The computed results are in good agreement with experimental data, especially for the carrier phase. However, the predicted turbulence fluctuations associated with the discrete phase are lower than the data at the downstream region of the flow field.

Nikjooy, M.↗

Numerical Study of Stratified Charge Combustion in Wave Rotors

A wave rotor may be used as a pressure-gain combustor effecting non-steady flow, and intermittent, confined combustion to enhance gas turbine engine performance. It will be more compact and probably lighter than an equivalent pressure-exchange wave rotor, yet will have similar thermodynamic and mechanical characteristics. Because the allowable turbine blade temperature limits overall fuel/air ratio to sub-flammable values, premixed stratification techniques are necessary to burn hydrocarbon fuels in small engines with compressor discharge temperature well below autoignition conditions. One-dimensional, unsteady numerical simulations of stratified-charge combustion are performed using an eddy-diffusivity turbulence model and a simple reaction model incorporating a flammability limit temperature. For good combustion efficiency, a stratification strategy is developed which concentrates fuel at the leading and trailing edges of the inlet port. Rotor and exhaust temperature profiles and performance predictions are presented at three representative operating conditions of the engine: full design load, 40% load, and idle. The results indicate that peak local gas temperatures will result in excessive temperatures within the rotor housing unless additional cooling methods are used. The rotor itself will have acceptable temperatures, but the pattern factor presented to the turbine may be of concern, depending on exhaust duct design and duct-rotor interaction.

Nalim, M. Razi↗

Rotor blade system with reduced blade-vortex interaction noise

A rotor blade system with reduced blade-vortex interaction noise includes a plurality of tube members embedded in proximity to a tip of each rotor blade. The inlets of the tube members are arrayed at the leading edge of the blade slightly above the chord plane, while the outlets are arrayed at the blade tip face. Such a design rapidly diffuses the vorticity contained within the concentrated tip vortex because of enhanced flow mixing in the inner core, which prevents the development of a laminar core region.

Leishman, John G.↗

CFD Simulation of an Inward-Turning Supersonic Inlet Unstart at Flight Mach Number 1.7

Interest in inward-turning supersonic inlets renewed during NASA’s Commercial Supersonic Technology Project, as a means of reducing disturbances caused by propulsion integration. Inward-turning designs have the potential to greatly reduce the strength of shock waves emanating outward from the nacelle, and therefore their contribution to the overall sonic boom signature. For top-mounted, or over-wing installations, disturbances to aircraft aerodynamics are reduced. The nature of the inward-turning geometry results in a boundary-layer thickening effect, opposite that of the familiar thinning of an outward-turning cone boundary-layer. The application of a small amount of boundary-layer bleed at the throat has been shown to alleviate the negative effects of the boundary-layer on subsonic diffuser performance. Boundary-layer bleed, however, comes at the expense of increased complexity, and external disturbances at bleed exits that would partially defeat the purpose of the inward-turning scheme. Vortex generators were proposed as an alternative to bleed, and an initial CFD study of their effectiveness in this application forms the basis of the present work. A source-term model in the Wind-US CFD code was used to model the effects of an array of vortex generators placed at the entrance to the subsonic diffuser. Baseline results with no vortex generators compared favorably to previously reported results with no bleed at back-pressures near the design point, but stability margin in the present case was limited by a curious non-linear phenomena similar to unstart in mixed-compression inlets. While some improvement was noted with vortex generators, their effectiveness was diminished by the limited stability margin. A time-accurate calculation was subsequently performed to better understand this process. Results of this calculation are presented and instantaneous solutions compared with steady-state, subcritical results previously reported. The stability margin limitation is attributed to the use of a constant-pressure outflow boundary condition, which differed from that used in the prior simulations.

Pre-Compressor Cooling, Water Injection, Hypersoni↗

Theoretical and experimental internal flow characteristics of a 13.97-centimeter-diameter inlet at STOL takeoff and approach conditions

The theoretical and experimental internal flow characteristics of a 13.97-cm-diam inlet with centerbody retracted and extended are presented at STOL takeoff and approach operating conditions. The theoretical results were obtained from incompressible potential flow corrected for compressibility and boundary layer. Comparisons between theoretical internal surface static-pressure distributions and experimental data are presented for free-stream velocities of 0, 24, 32, and 45 m/sec for a range of inlet incidence angles from 0 to 50 deg. Surface static-pressure distributions are illustrated at circumferential locations of 0, 60, 120, and 180 deg. Surface Mach number distributions from the stagnation point to the diffuser exit are presented along with turbulent boundary-layer shape factors. In general, good agreement was found between the theoretical and experimental surface static pressure distributions.

Albers, J. A.↗

Modeling of InP metalorganic chemical vapor deposition

The growth of InP by metalorganic chemical vapor deposition (MOCVD) in a horizontal reactor is being modeled with a commercially available computational fluid dynamics modeling code. The mathematical treatment of the MOCVD process has four primary areas of concern: 1) transport phenomena, 2) chemistry, 3) boundary conditions, and 4) numerical solution methods. The transport processes involved in CVD are described by conservation of total mass, momentum, energy, and atomic species. Momentum conservation is described by a generalized form of the Navier-Stokes equation for a Newtonian fluid and laminar flow. The effect of Soret diffusion on the transport of particular chemical species and on the predicted deposition rate is examined. Both gas-phase and surface chemical reactions are employed in the model. Boundary conditions are specified at the inlet and walls of the reactor for temperature, fluid flow and chemical species. The coupled set of equations described above is solved by a finite difference method over a nonuniform rectilinear grid in both two and three dimensions. The results of the 2-D computational model is presented for gravity levels of zero- and one-g. The predicted growth rates at one-g are compared to measured growth rates on fused silica substrates.

Black, Linda R.↗

FORTRAN program for predicting off-design performance of centrifugal compressors

A FORTRAN program for calculating the off-design performance of centrifugal compressors with channel diffusers is presented. Use of the program requires complete knowledge of the overall impeller and diffuser geometries. Individual losses are computed using analytical equations and empirical correlations which relate loss levels to velocity diagram characteristics and overall geometry. On a given speed line compressor performance is calculated for a range of inlet velocity levels. At flow rates between surge and choke, individual efficiency decrements, compressor overall efficiency, and compressor total pressure ratio are tabulated. An example case of performance comparison with a compressor built by a commercial engine manufacturer is presented to demonstrate the correlation with limited experimental data.

Galvas, M. R.↗

Performance at Mach 3.52 of a Mach 2.5 all external-compression, two dimensional inlet

A quick-look test was conducted in the 10- by 10-foot supersonic wind tunnel to provide some qualitative information on operating a low Mach number design inlet in a highly oversped condition. The model which is a two-dimensional, three-ramp, all-external-compression inlet designed to match a J-85 turbojet engine at Mach 2.5 was run at Mach 3.52 and zero angle-of-attack and yaw. Results are presented showing the effect of external ramp angle combinations, diffuser ramp position, and amount of bleed.

Cubbison, R. W.↗

Augmenting ejector endwall effects

Rectangular inlet ejectors which had multiple hypermixing nozzles for their primary jets were investigated for the effects of endwall blowing on thrust augmentation performance. The ejector configurations tested had both straight wall and active boundary layer control type diffusers. Endwall flows were energized and controlled by simple blowing jets suitably located in the ejector. Both the endwall and boundary layer control diffuser blowing rates were varied to determine optimum performance. High area ratio diffusers with insufficient endwall blowing showed endwall separation and rapid degradation of thrust performance. Optimized values of diffuser boundary layer control and endwall nozzle blowing rates in an ejector augmenter were shown to achieve high levels of augmentation performance for maximum compactness.

Porter, J. L.↗

Flow control in a diffusing S-Duct

Accurate measurements have been made of secondary flow in a 1.51 area ratio diffusing 30 deg - 30 deg S-Duct with circulair cross section. Turbulent flow was entering the duct at Mach number of 0.6, the boundary layer thickness at the duct entrance was ten percent of the duct inlet diameter. Through measurements made, local flow velocity vector as well as static and total pressures mapping of the flow at several stations were obtained. Strong secondary flow was measured in the first bend which continued into the second bend with new vorticity produced in there in the opposite direction. Surface oil flow visualization and wall pressures indicated a region of separated flow starting at theta approximately equal to 22 deg on the inside of the first bend up to theta approximately equal to 44 deg on the outside of the second bend. The flow separated in 'cyclone' form and never reattached in the duct. As a result of the secondary flow and the flow separation, significant total pressure distortion was observed at the exit of the duct. Using flow control devices the separation was eliminated while the exit distortion was improved.

Vakili, A. D.↗

A numerical and experimental study of coaxial jets

An algebraic stress model and the standard k-epsilon model is applied to predict the mean and turbulence quantities for axisymmetric, nonswirling coaxial jets without confinement. To investigate the effects of numerical (false) diffusion on the predicted results, three different discretization schemes, namely, hybrid, power-law, and the flux-spline, are employed. In addition, an experimental study is conducted to provide data of good quality, especially near the inlet, for model assessment. The results show that the use of the algebraic stress model leads to better agreement between the numerical results and experimental data.

Nikjooy, M.↗

CCN data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow is directed through a cyclone impactor (Brechtel, Inc. Model SCC 0.732) and 0.5 LPM is directed to the CCN. To calculate particle losses, we used a two-step method. First, the measured SMPS size distributions were used to calculate particle loss through the inlet during sampling. Second, the corrected SMPS data was used to calculate the average of the total losses per scan down the CCN line. Then, the correction was applied to the CCN data. This calculation was done separately for each deployment location due to changes in the measured size distributions between locations. Particle loss from diffusion (based on Kesten, 1991 and Gormley, 1949), inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977), and cyclone impactor efficiency (based on Dirgo, 1985) were included in the loss calculation. When the SMPS was not sampling at a location (in the case of an instrument malfunction or operator error), the reported CPC data was corrected with an average of the total losses for the entire campaign at the specified deployment location (e.g., if we needed to correct Galveston data, then the average of all calculated losses at Galveston was taken). These flatline corrections were used for all data on 22/07/13, 22/07/20, 22/07/22, and the data from Galveston on 22/08/09. The supersaturation uncertainty is estimated conservatively at +/- 0.03%, where variation in the inlet temperature, pressure, and calibration technique prevents a more accurate measurement. Confidence in the reported supersaturation measurements is based on a pre-campaign calibration (following the methods from our previous work and Deng, 2014 based on Rose, 2008) in addition to inter-comparisons with the DOE for two days (22/08/18 and 22/09/01) where TAMU was co-located with AMF1. The inter-comparisons show good agreement between our instrument and the DOEs instrument on both days at all supersaturations. After the last inter-comparison on 22/09/01, there was no indication of a malfunction by our instrument through the rest of the campaign. Unfortunately, the instrument was dropped during demobilization. A post-campaign calibration was conducted, which showed a substantial departure from the pre-campaign calibration. The drop may have damaged the instrument’s ability to produce the desired supersaturations. Therefore, we do consider the data after 22/09/01 to be correct, but it should be used with caution. The CCN counter sampled for 3 minutes at each supersaturation setpoint (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%). At the end of a cycle, the instrument was set to 0.01% supersaturation for 5 minutes. The data is comprised of the last 60 seconds of each supersaturation set point (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%) to ensure the instrument stabilized and was able to reach thermal equilibrium. We removed the data during the periods where there were operational difficulties, setup, or maintenance. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Rose et. al. Calibration and Measurement Uncertainties of a Continuous-Flow Cloud Condensation Nuclei Counter (DMT-CCNC): CCN Activation of Ammonium Sulfate and Sodium Chloride Aerosol Particles in Theory and Experiment. Atmos. Chem. Phys., 8, 1153-1179, 2008. Deng et. al. Using Raman Microspectroscopy to Determine Chemical Composition and Mixing State of Airborne Marine Aerosols over the Pacific Ocean. Aerosol Science and Technology, Vol 48, Issue 2, 2014. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977. Dirgo et. al. Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions. Aerosol Science and Technology, 4:4, 401-415, 1985.

54 ENVIRONMENTAL SCIENCES↗

Identification and Characterization of Thermal Fluid Phenomena Associated with Selected Operating/Accident Scenarios in Modular High Temperature Gas-cooled Reactors

Dominant phenomena are identified and characterized for the loss-of-forced-convection (LOFC) scenario, the depressurized loss-of-forced-convection (DLOFC) scenario, and the moisture ingress scenario with relief valves available scenario. These scenarios are considered for the modular high temperature gas-cooled reactor (MHTGR) baseline design—with both a prismatic core and a pebble-bed core. The objectives of this effort, described in the above paragraph, were achieved by following a methodology identified by the U.S. Nuclear Regulatory Commission (NRC) and recommended in their Regulatory Guide 1.203. The methodology employed is described. For the above scenarios, baseline phenomena identification and ranking tables (PIRTs) generated by a NRC-sponsored effort in 2008 for the LOFC and DLOFC scenarios and a baseline PIRT generated by a Department of Energy-sponsored effort in 2011 by their Next Generation Nuclear Plant (NGNP) Moisture Ingress Assessment Committee were used to identify the dominant phenomena and existing levels-of-knowledge. Ten dominant phenomena (with only medium or low levels-of-knowledge) were identified for the LOFC and DLOFC scenarios including: (1) Inlet plenum stratification and plumes, (2) core coolant flow distribution, (3) radiant heat transfer from the top of the core to the upper vessel head, (4) reactor cavity air circulation and heat transfer, (5) reactor cavity cooling system behavior, (6) decay heat distributions, (7) core effective thermal conductivity, (8) molecular diffusion in air ingress DLOFC, (9) duct exchange flow, (10) phenomena that affect cavity gas composition for air-ingress. Five dominant phenomena, with high levels of knowledge, were identified for the moisture-ingress scenario with relief valves available including: (1) flow through break, (2) moisture level in the primary, (3) transport to moisture monitor, (4) moisture monitor instrument response, and (5) heat removal by shutdown cooling system. These phenomena are discussed and characterized. A listing of experiments—both completed and ongoing—is given with a view toward including data useful for further more detailed examination of the dominant phenomena listed in the previous paragraph. Note that only data for the LOFC and DLOFC scenarios are listed—since the moisture ingress scenario with relief valves available –have been identified as having adequate levels-of-knowledge by the PIRT committee. Finally, a preliminary computational fluid dynamics (CFD) calculation of inlet plenum stratification and plumes is described. Techniques employed for this calculation are typical for preliminary scoping calculations performed to validate numeric tools.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗