Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Instantaneous velocity field imaging instrument for supersonic reacting flows

The technical tasks conducted to develop and demonstrate a new gas velocity measurement technique for high enthalpy reacting flows is described. The technique is based on Doppler-shifted Planar Laser-induced Fluorescence (PLIF) imaging of the OH radical. The imaging approach permits, in principle, single-shot measurements of the 2-D distribution of a single velocity component in the measurement plane, and is thus a technique of choice for applications in high enthalpy transient flow facilities. In contrast to previous work in this area, the present program demonstrated an approach which modified the diagnostic technique to function under the constraints of practical flow conditions of engineering interest, rather than vice-versa. In order to accomplish the experimental demonstrations, the state-of-the-art in PLIF diagnostic techniques was advanced in several ways. Each of these tasks is described in detail and is intended to serve as a reference in supporting the transition of this new capability to the fielded PLIF instruments now installed at several national test facilities. Among the new results of general interest in LlF-based flow diagnostics, a detailed set of the first measurements of the collisional broadening and shifting behavior of OH (1,0) band transitions in H7-air combustion environments is included. Such measurements are critical in the design of a successful strategy for PLIF velocity imaging; they also relate to accurate concentration and temperature measurements, particularly in compressible flow regimes. Furthermore, the results shed new light on the fundamental relationship between broadening and energy transfer collisions in OH A(sup 2)Sigma(+)v(sup ') = 1. The first single-pulse, spectrally-resolved measurements of the output of common pulsed dye lasers were also produced during the course of this effort. As with the OH broadening measurements, these data are a significant aspect of a successful velocity imaging strategy, and also have potential implications for many other LIF measurement techniques. Our results indicated the need to modify the commercially available laser cavity in order to accommodate the constraints imposed by typical SCRAMJET combustion characteristics as well as to increase the instrument's velocity dynamic range to span an intra-image range in excess of 2 km/s. The various technical efforts were brought together in a series of experiments demonstrating the applicability of the technique in a high pressure, high temperature H2-air combustion system. The resultant images were compared with 2-D flow simulations in order to determine the accuracy of the instrument. Mean velocity imaging in flows with an axis of symmetry was demonstrated with an accuracy of +/- 50 m/s out of an intra-image dynamic range of 1600 m/s, including reversed flow. A more complex configuration amenable to single-shot imaging in flows without an axis of symmetry was also demonstrated. Limitations imposed by available equipment resulted in an accuracy of about +/- 200 m/s out of 1750 m/s in these demonstrations. Minor modifications to the present configuration were suggested to improve this performance. Each technical task is described in detail, along with significance of the results for the overall imaging velocimeter configuration. This report should allow the user community to integrate this new measurement capability in their existing instrumentation platforms.

Allen, M. G.↗

Laser light scattering instrument advanced technology development

The objective of this advanced technology development (ATD) project has been to provide sturdy, miniaturized laser light scattering (LLS) instrumentation for use in microgravity experiments. To do this, we assessed user requirements, explored the capabilities of existing and prospective laser light scattering hardware, and both coordinated and participated in the hardware and software advances needed for a flight hardware instrument. We have successfully breadboarded and evaluated an engineering version of a single-angle glove-box instrument which uses solid state detectors and lasers, along with fiber optics, for beam delivery and detection. Additionally, we have provided the specifications and written verification procedures necessary for procuring a miniature multi-angle LLS instrument which will be used by the flight hardware project which resulted from this work and from this project's interaction with the laser light scattering community.

Wallace, J. F.↗

Harvard ER-2 OH laser-induced fluorescence instrument

The Harvard ER-2 OH instrument is scheduled to be integrated into the NASA ER-2 high altitude aircraft ozone payload in August 1992. Design and fabrication is presently underway. This experiment is a descendant of a balloon borne instrument designed and built in the mid-1980s. The ER-2 instrument is being designed to measure OH and HO2 as part of the NASA ozone payload for the investigation of processes controlling the concentration of stratospheric ozone. Although not specifically designed to do so, it is hoped that valid measurements of OH and HO2 can be made in the remote free troposphere with this instrument.

Wennberg, Paul O.↗

Innovative instrumentation for mineralogical and elemental analyses of solid extraterrestrial surfaces: The Backscatter Moessbauer Spectrometer/X Ray Fluorescence analyzer (BaMS/XRF)

We have developed a four-detector research-grade backscatter Moessbauer spectrometer (BaMS) instrument with low resolution x-ray fluorescence analysis (XRF) capability. A flight-qualified instrument based on this design would be suitable for use on missions to the surfaces of solid solar-system objects (Moon, Mars, asteroids, etc.). Target specifications for the flight instrument are as follows: mass less than 500 g; volumes less than 300 cu cm; and power less than 2 W. The BaMS/XRF instrument would provide data on the oxidation state of iron and its distribution among iron-bearing mineralogies and elemental composition information. This data is a primary concern for the characterization of extraterrestrial surface materials.

Shelfer, T. D.↗

An instrumented fastener for shear force measurements in joints

Results are presented of a preliminary investigation of instrumented fasteners for use as sensors to measure the shear loads transmitted by individual fasteners installed in double splice joints. Calibration and load verification tests were conducted for instrumented fasteners installed at three fastener torque levels. Calibration test results show that the shear strains obtained from the instrumented fasteners vary linearly with the applied load and that the instrumented fasteners can be effectively used to measure shear loads transmitted by individual fasteners installed in double splice joints. The load distribution between individual fasteners is found to be dependent on the location of the fastener in the joint and the fastener torque level.

Sawyer, James W.↗

An instrument to measure the charge, and energy spectrum (20-1000 GeV/a) of the cosmic ray species oxygen to iron

BUGS-4 (Bristol University Gas Scintillator-4) made its maiden engineering flight from Fort Summer (NM) on the 29th of September 1993. The instrument was consumed by fire after striking a power line during landing following 24 hours at float. The analysis of the telemetered data from this sophisticated instrument is a demanding task. Early analysis was compromised by electronic artifacts. Unravelling these problems has been difficult and time consuming, especially as the flight hardware was burned beyond salvage, but is is an essential preliminary to analysis. During this report period we have concentrated on a small sub-set of data (the first 30,000 events; 90 minutes at float), and developed software algorithms to correct systematic errors. Using these corrected events we have begun to develop the analysis algorithms. Although the analysis is preliminary, and restricted to the first 30,000 events, the results are encouraging, and suggest the design concepts are well matched to this application. Further work will refine the analysis, and allow quantitative evaluation of the concepts employed in BUGS-4 for applicability to future instruments. We believe this work will justify fabrication of a new instrument employing techniques deployed on BUGS-4.

Gregory, J. C.↗

Dynamic Stability Instrumentation System (DSIS). Volume 1: Hardware description

This paper is a hardware description manual for the Dynamic Stability Instrumentation System that is used in specific NASA Langley wind tunnels. The instrumentation system performs either a synchronous demodulation or a fast Fourier transform on dynamic balance strain gage signals, and ultimately computes aerodynamic coefficients. The DSIS consists of a double rack of instruments, a remote motor-generator set, two special stings each with motor driven shafts, and specially designed balances. The major components in the instrumentation rack include a personal computer, digital signal processor microcomputers, computer-controlled signal conditioners, function generator, digital multimeter, and an optional fast Fourier transform analyzer.

Jordan, T. L.↗

Analysis of solar spectral irradiance measurements from the SBUV/2-series and the SSBUV instruments

The measurements of the solar ultraviolet spectral irradiance by the two Upper Atmosphere Research Satellite (UARS) solar instruments are validated to agree within their 2-Sigma calibration uncertainties of about 7 percent, as well as with measurements from the two solar instruments on the Shuttle Atmospheric Laboratory for Applications and Science (ATLAS) missions. Additionally, the precision of the two UARS data sets is better than the original 2 percent goal, especially at wavelengths greater than 160 nm. This excellent agreement can be credited to accurate pre-flight calibrations, comprehensive in-flight calibrations to track instrument degradation, and a coordinated validation program among the UARS and ATLAS solar instrument teams. The solar irradiance results presented here include those derived from UARS SUSIM, UARS SOLSTICE, ATLAS SUSIM and ATLAS SSBUV measurements on 29 March 1992 during the ATLAS-1 mission and on 15 April 1993 during the ATLAS-2 mission. Two ultraviolet spectra from 119 to 410 nm are derived as the weighted average of the UARS SOLSTICE and SUSIM measurements and are recommended as representative solar spectra for the period of the ATLAS-1 and ATLAS-2 missions. The ATLAS-1 mission occurred during the initial phase of the solar cycle 22 decline when solar activity was moderately high. The ATLAS-2 mission occurred later during the declining phase of the solar cycle 22 when solar activity was more moderate.

Cebula, Richard P.↗

SPICE: An innovative, flexible instrument concept

Studies and plans for orbital capture of cosmic dust and interplanetary dust particles (IDP's) looked very bright with the advent of space station Freedom (SSF) and formal selection of Cosmic Dust Collection Facility (CDCF) as an attached payload in 1990. Unfortunately it has been downhill since its selection, culminating in CDCF being dropped as attached payload in the SSF redesign process this year. This action was without any input from the science or cosmic dust communities. The Exobiology Intact Capture Experiment (Exo-ICE) as an experiment on CDCF was also lost. Without CDCF, no facility-class instrument for cosmic dust studies is available or planned. When CDCF (and Exo-ICE) was selected as a SSF attached payload, an exercise called the small particle intact capture experiment (SPICE) was started for Exo-ICE to develop an understanding and early testing of the necessary expertise and technology for intact capture of cosmic dust and IDP's. This SPICE activity looks to fly small, meter square or less, collection area experiments on early orbital platforms of opportunity such as EURECA, MIR, WESTAR, and others, including the shuttle. The SPICE activity has focused on developing techniques and instrument concepts to capture particles intact and without inadvertent contamination. It began with a survey and screening of available capture media concepts and then focused on the development of a capture medium that can meet these requirements. Evaluation and development of the chosen capture medium, aerogel (a silicon oxide gel), has so far lived up to the expectations of meeting the requirements and is highlighted in a companion paper at this workshop. Others such as McDonnell's Timeband Capture Cell Experiment (TICCE) on EuReCa and Tsuo's GAS-CAN lid experiments on STS 47 and 57 have flown aerogel, but without addressing the contamination issue/requirement, especially regarding organics. Horz, Zolenskym and others have studied and have also been advocates for its development. The SPICE instrument's experiment design builds on the knowledge gained from these efforts to meet the intact capture, noncontamination requirements. An overview of a possible SPICE experimental instrument concept using the MIR space station as a host platform for cosmic dust collection is provided in this paper. The SPICE concept is nonplatform-specified and can fly on any platform that provides a mode for experiment recovery.

Nishioka, Kenji↗

Calibration of the COBE FIRAS instrument

The Far-Infrared Absolute Spectrophotometer (FIRAS) instrument on the Cosmic Background Explorer (COBE) satellite was designed to accurately measure the spectrum of the cosmic microwave background radiation (CMBR) in the frequency range 1-95/cm with an angular resolution of 7 deg. We describe the calibration of this instrument, including the method of obtaining calibration data, reduction of data, the instrument model, fitting the model to the calibration data, and application of the resulting model solution to sky observations. The instrument model fits well for calibration data that resemble sky condition. The method of propagating detector noise through the calibration process to yield a covariance matrix of the calibrated sky data is described. The final uncertainties are variable both in frequency and position, but for a typical calibrated sky 2.6 deg square pixel and 0.7/cm spectral element the random detector noise limit is of order of a few times 10(exp -7) ergs/sq cm/s/sr cm for 2-20/cm, and the difference between the sky and the best-fit cosmic blackbody can be measured with a gain uncertainty of less than 3%.

Fixsen, D. J.↗

An intercomparison of instrumentation for tropospheric measurements of dimethyl sulfide: Aircraft results for concentrations at the parts-per-trillion level

This paper reports results from NASA's Chemical Instrumentation and Test Evaluation (CITE 3) during which airborne measurements of dimethyl sulfide (DMS) from six instruments were intercompared. Represented by the six instruments are three fundamentally different detection principles (flame photometric, mass spectrometric, and electron capture after fluorination); three collection/preconcentration methods (cryogenic, gold wool absorption, and polymer absorbent); and three types of oxidant scrubbers (solid phase alkaline, aqueous reactor, and cotton). The measurements were made over the Atlantic Ocean in August/September 1989 during flights from NASA's Wallops Flight Center, Virginia, and Natal, Brazil. The majority of the intercomparisons are at DMS mixing ratios less than 50 pptv. Results show that instrument agreement is of the order of a few pptv for mixing ratios less than 50 pptv and to within about 15% above 50 pptv. Statistically significant (95% confidence) measurement biases were noted among some of the techniques. However, in all cases, any bias is small and within the accuracy of the measurements and prepared DMS standards. Thus, we conclude that the techniques intercompared during CITE 3 provide equally valid measurements of DMS in the range of a few pptv to 100 pptv (upper range of the intercomparisons).

Gregory, Gerald L.↗

An instrumented fastener for shear force measurements in joints

A preliminary investigation has been conducted on instrumented fasteners for use as sensors to measure the shear loads transmitted by individual fasteners installed in double-splice joints. Calibration and load verification tests were conducted for instrumented fasteners installed at three fastener torque levels. Results from calibration tests show that the shear strains obtained from the instrumented fasteners vary linearly with the applied load and that the instrumented fasteners can be effectively used to measure shear loads transmitted by individual fasteners installed in double-splice joints. Tests were also conducted with three instumented fasteners installed in a typical double-splice joint. The test results showed that the load distribution between individual fasteners is dependent on the location of the fastener in the joint and the fastener torque level.

Sawyer, J. W.↗

Optoelectronic Instruments For Analysis Of Surface Defects

Family of portable optoelectronic instruments developed to facilitate inspection of surface flaws like gouges, scratches, raised metal, and dents on large metal workpieces subject to surface-finish requirements. Instrument brought to workpiece and semiautomatically makes electronic record of three-dimensional shape of flaw. Entire inspection process takes only minutes. Prototype instrument includes structured-light microscope. Concept involves projection of known pattern of light onto surface inspected. Topography of surface determined from distortion of pattern as viewed through instrument.

Collins, J. David↗

Active Flow Control: Instrumentation Automation and Experimental Technique

In investigating the potential of a new actuator for use in an active flow control system, several objectives had to be accomplished, the largest of which was the experimental setup. The work was conducted at the NASA Langley 20x28 Shear Flow Control Tunnel. The actuator named Thunder, is a high deflection piezo device recently developed at Langley Research Center. This research involved setting up the instrumentation, the lighting, the smoke, and the recording devices. The instrumentation was automated by means of a Power Macintosh running LabVIEW, a graphical instrumentation package developed by National Instruments. Routines were written to allow the tunnel conditions to be determined at a given instant at the push of a button. This included determination of tunnel pressures, speed, density, temperature, and viscosity. Other aspects of the experimental equipment included the set up of a CCD video camera with a video frame grabber, monitor, and VCR to capture the motion. A strobe light was used to highlight the smoke that was used to visualize the flow. Additional effort was put into creating a scale drawing of another tunnel on site and a limited literature search in the area of active flow control.

Gimbert, N. Wes↗

Dynamic Stability Instrumentation System (DSIS): User Manual - Volume 3

The paper is an operating manual for the Dynamic Stability Instrumentation System in specific NASA Langley wind tunnels. The instrumentation system performs either a synchronous demodulation or a Fast Fourier Transform on dynamic balance strain gage signals, and ultimately computes aerodynamic coefficients. The dynamic balance converts sting motor rotation into pitch or yaw plane or roll axis oscillation, with timing information provided by a shaft encoder. Additional instruments control model attitude and balance temperature and monitor sting vibrations. Other instruments perform self-calibration and diagnostics. Procedures for conducting calibrations and wind-off and wind-on tests are listed.

Daniels, Taumi S.↗

Two Instruments for Measuring Distributions of Low-Energy Charged Particles in Space

Current estimates indicate that the bulk of interplanetary gas consists of protons with energies between 0 and 20 kev and concentrations of 1 to 105 particles/cu cm. Methods and instrumentation for measuring the energy and density distribution of such a gas are considered from the standpoint of suitability for space vehicle payloads. It is concluded that electrostatic analysis of the energy distribution can provide sufficient information in initial experiments. Both magnetic and electrostatic analyzers should eventually be used. Several instruments designed and constructed at the Ames Research Center for space plasma measurements, and the methods of calibration and data reduction are described. In particular, the instrument designed for operation on solar cell power has the following characteristics: weight, 1.1 pounds; size, 2 by 3 by 4 inches; and power consumption, 145 mw. The instrument is designed to yield information on the concentration, energy distribution, and the anisotropy of ion trajectories in the 0.2 to 20 kev range.

Bader, Michel↗

Analysis of the Cyclotron Facility Calibration and Aircraft Results Obtained by LIULIN-3M Instrument

The LIULIN-3M instrument is a further development of the LIULIN dosimeter-radiometer, which has been used on the NffR space station in the 1988-1994 time period, The LIULIN-3M is designed for continuous monitoring of the radiation environment during the BION-12 satellite flight in 1999. A semiconductor detector with 1 mm thickness and 1 cm(exp 2) area is used in the instrument. Pulse high analysis technique is used for measurement of the energy losses in the detector. The final data sets from the instrument are the flux and the dose rate for the exposition time and 256 channels of LET spectra if a non-nal coincidence of the particles to the detector is considered. The LIULIN-3M instrument was calibrated by proton fluxes with different energies at the Indiana University Cyclotron Facility in June 1997 and was used for space radiation measurements during commercial aircraft flights. Obtained calibration and flight results are analyzed in the paper.

Dachev, T. P.↗

Design of a Channel Error Simulator using Virtual Instrument Techniques for the Initial Testing of TCP/IP and SCPS Protocols

There exists a need for designers and developers to have a method to conveniently test a variety of communications parameters for an overall system design. This is no different when testing network protocols as when testing modulation formats. In this report, we discuss a means of providing a networking test device specifically designed to be used for space communications. This test device is a PC-based Virtual Instrument (VI) programmed using the LabVIEW(TM) version 5 software suite developed by National Instruments(TM)TM. This instrument was designed to be portable and usable by others without special, additional equipment. The programming was designed to replicate a VME-based hardware module developed earlier at New Mexico State University (NMSU) and to provide expanded capabilities exceeding the baseline configuration existing in that module. This report describes the design goals for the VI module in the next section and follows that with a description of the design of the VI instrument. This is followed with a description of the validation tests run on the VI. An application of the error-generating VI to networking protocols is then given.

Horan, Stephen↗