Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOADS - DISKS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Diesel Particulate Filter Durability Performance Comparison Using Metals Doped B20 vs. Conventional Diesel Part I: Accelerated Ash Loading and DPF Performance Evaluation

The project objective was to generate experimental data to evaluate the impact of metals doped B20 on DPF ash loading and performance compared to that of conventional petrodiesel. Accelerated ash loading was conducted on two DPFs - one exposed to regular diesel fuel and the other to B20 containing metal dopants equivalent to 4 ppm B100 total metals (currently total metals are limited to 10 ppm in ASTM D6751, the standard for B100). Periodic performance evaluations were conducted on the DPFs at 10 g/L ash loading intervals. After the evaluations at 30 g/L, the DPF was cleaned with a commercial DPF cleaning machine and another round of DPF evaluations were conducted. A comparison of the effect of ash loading with the two fuels and DPF cleaning is presented. The metals doped B20 fuel resulted in ash that was similar to that deposited when exposed to ULSD (lube oil ash) and exhibited similar ash cleaning removal efficiency. Metals doped B20 resulted in faster ash accumulation within the DPF, as expected, but did not appear to have a negative effect on DPF pressure drop or regeneration rates (up to 30 g/L of ash) or exhibit deleterious physical effects on the DPF substrate.

ADVANCED PROPULSION SYSTEMS,BIOMASS FUELS↗

Upwind vs. downwind: loads and acoustics of a 1.5 MW wind turbine

This paper discusses the motivation, preparation, risk mitigation, execution, and results of a full-scale experiment where the conventional upwind rotor of a 1.5 MW wind turbine was operated in a downwind configuration. The experiment took place at the National Renewable Energy Laboratory Flatirons Campus in Colorado, USA, and involved the collection of loads and power together with acoustic measurements from an array of four microphones. To validate the numerical predictions of the aeroelastic solver OpenFAST in terms of loads and performance, 410 min of downwind operation and 960 min of conventional upwind operations were used. In the wind speed range from 4.5 to 12.5 m s−1, the downwind rotor generates higher damage equivalent loads for the blade root flapwise moment, blade root edgewise moment, and tower-base fore-aft moment compared to the upwind rotor. For these metrics of fatigue loads, numerical predictions match the experimental observations well. OpenFAST is, however, also seen underpredicting a power gain in the downwind rotor. In terms of acoustics, the overall sound pressure levels recorded in the field are similar between the upwind and downwind cases, but downwind operation worsens the metrics describing amplitude modulation.

17 WIND ENERGY↗

Added value of site load measurements in probabilistic lifetime extension: a Lillgrund case study

Site-specific fatigue estimation is an essential part of wind turbine lifetime extension, with various methods depending on data availability. The present study compares probabilistic lifetime extension assessment results for rotor blades with and without load measurements. It also addresses two key questions in such assessments: the applicability of the Frandsen model for estimating waked turbulence under complex and mixed wake conditions and the extrapolation of mid-term data over longer time periods. The case study wind turbine is SWT-2.3-93, located at the edge of the Lillgrund wind farm, situated in the Øresund Strait between Denmark and Sweden. The turbine is extensively instrumented, with 5 years of data available from its supervisory control and data acquisition (SCADA) system. Although the Frandsen turbulence estimates deviate in a different manner from measurements at below- and above-rated mean wind speeds, the model remains a conservative approach for fatigue load prediction and reliability. In the current case study, the site-specific assessment using strain gauge measurements yields a 33 % higher annual fatigue reliability index after 35 years compared to a scenario based on the Frandsen estimation combined with ambient environmental data and a generic aeroelastic model. The results also demonstrate that the sensitivity of fatigue reliability to load uncertainty is negligible when load measurements are used directly but relatively high when relying on the Frandsen model in combination with a generic aeroelastic model. Overall, the high variability of the lifetime extension in different scenarios of data availability and accuracy shows the importance and added value of high-quality measurements combined with wind-farm-level SCADA and a model updated in real time (digital twins).

17 WIND ENERGY↗

OC6 project Phase III: validation of the aerodynamic loading on a wind turbine rotor undergoing large motion caused by a floating support structure

Abstract. This paper provides a summary of the work done within Phase III of the Offshore Code Comparison Collaboration, Continued, with Correlation and unCertainty (OC6) project, under the International Energy Agency Wind Technology Collaboration Programme Task 30. This phase focused on validating the aerodynamic loading on a wind turbine rotor undergoing large motion caused by a floating support structure. Numerical models of the Technical University of Denmark 10 MW reference wind turbine were validated using measurement data from a 1:75 scale test performed during the UNsteady Aerodynamics for FLOating Wind (UNAFLOW) project and a follow-on experimental campaign, both performed at the Politecnico di Milano wind tunnel. Validation of the models was performed by comparing the loads for steady (fixed platform) and unsteady (harmonic motion of the platform) wind conditions. For the unsteady wind conditions, the platform was forced to oscillate in the surge and pitch directions under several frequencies and amplitudes. These oscillations result in a wind variation that impacts the rotor loads (e.g., thrust and torque). For the conditions studied in these tests, the system aerodynamic response was almost steady. Only a small hysteresis in airfoil performance undergoing angle of attack variations in attached flow was observed. During the experiments, the rotor speed and blade pitch angle were held constant. However, in real wind turbine operating conditions, the surge and pitch variations would result in rotor speed variations and/or blade pitch actuations, depending on the wind turbine controller region that the system is operating. Additional simulations with these control parameters were conducted to verify the fidelity of different models. Participant results showed, in general, a good agreement with the experimental measurements and the need to account for dynamic inflow when there are changes in the flow conditions due to the rotor speed variations or blade pitch actuations in response to surge and pitch motion. Numerical models not accounting for dynamic inflow effects predicted rotor loads that were 9 % lower in amplitude during rotor speed variations and 18 % higher in amplitude during blade pitch actuations.

17 WIND ENERGY↗

Codisposal Waste Package Loading Options for DOE SNF and HLW

The U.S. Department of Energy (DOE) is responsible for managing spent nuclear fuel (SNF) that is currently in, or will in the future come into, its possession. DOE must continue to safely store that SNF, transport it to an interim storage site or a repository, and dispose of it. These fuels come from a wide range of reactor types, such as light- and heavy-water-moderated reactors, graphite-moderated reactors, and breeder reactors, with various cladding materials and enrichments. Many of these reactors, now decommissioned, had unique design features, such as core configuration, fuel element and assembly geometry, moderator and coolant materials, operational characteristics, and neutron spatial and spectral properties resulting in a large diversity of reactor and fuel designs. Because of the wide variety and condition of SNF, a robust canister termed the DOE Standardized SNF Canister was proposed that would confine radionuclides and preclude moderator. The DOE Standard SNF Canister had four variations consisting of a 10- or 15-foot length and an 18- or 24-inch diameter. For ultimate disposal in the Yucca Mountain Repository these canisters were to be grouped with 24-inch diameter HLW canisters in a codisposal waste package. The 18-inch DOE Standardized SNF Canister could be placed in the middle of five HLW canisters. The 24-inch DOE Standardized SNF Canister would take the place of one the five HLW canister on the outer ring in the codisposal waste package. No DOE Standardized SNF Canisters have been loaded, and many fuel types can be loaded in multiple canisters. Depending on the selected diameter of the DOE Standardized SNF Canister for a particular fuel, the number of potential codisposal waste packages could vary. In addition, different types of DOE SNF may be able to be combined in a single canister. This could significantly change the number of DOE SNF canisters that are loaded and result in a decrease of the number of total potential codisposal waste packages. Ultimately, if too many HLW canisters need disposition, then a reduction in the number of DOE Standardized SNF Canisters will change the final total of codisposal waste packages very little. Likewise, if the ratio of DOE Standardized SNF Canisters to HLW canister produced is too high, then DOE Standardized SNF Canisters will not have enough HLW canisters to surround them in the codisposal waste package. This paper examines the results of differing loading strategies for a few DOE SNFs. It also compares the ranges of DOE Standardized SNF Canisters that may be produced to the ranges of HLW canisters that may be produced in order to determine potential scenarios.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Commercial building loads providing ancillary services In PJM

The adoption of low carbon energy technologies such as variable renewable energy and electric vehicles, coupled with the efficacy of energy efficiency to reduce traditional base load has increased the uncertainty inherent in the net load shape. Handling this variability with slower, traditional resources leads to inefficient system dispatch, and in some cases may compromise reliability. Grid operators are looking to future energy technologies, such as automated demand response (DR), to provide capacity-based reliability services as the need for these services increase. While DR resources are expected to have the flexibility characteristics operators are looking for, demonstrations are necessary to build confidence in their capabilities. Additionally, building owners are uncertain of the monetary value and operational burden of providing these services. To address this, the present study demonstrates the ability of demand response resources providing two ancillary services in the PJM territory, synchronous reserve and regulation, using an OpenADR 2.0b signaling architecture. The loads under control include HVAC and lighting at a big box retail store and variable frequency fan loads. The study examines performance characteristics of the resource: the speed of response, communications latencies in the architecture, and accuracy of response. It also examines the frequency and duration of events and the value in the marketplace which can be used to examine if the opportunity is sufficient to entice building owners to participate.

MacDonald, Jason↗

Methods and apparatus to modify a binary file for scalable dependency loading on distributed computing systems

Methods and apparatus to modify a binary file for scalable loading on distributed computing systems are disclosed. An example method to modify a binary file for scalable loading on a distributed computing system includes identifying, by executing an instruction with a processor, in the binary file a file name for a shared file, determining, by executing an instruction with the processor, whether the shared file can be loaded based on a path name specified in the binary file, and, responsive to a determination that the shared file can be loaded, generating, by executing an instruction with the processor, an identifier that can be used to access a local file scalably copied from a global file system, and modifying, by executing an instruction with the processor, the binary file by replacing, in the binary file, the file name with the generated identifier.

97 MATHEMATICS AND COMPUTING↗

Coordinated net-load management

A management device includes at least one processor communicatively coupled to at least one energy resource controller controlling at least one energy resource and to at least one deferrable load controller controlling power to at least one deferrable load. The is configured to receive an indication, determined based on a frequency value of an electrical network and a nominal frequency value, that a frequency anomaly event has occurred. Responsive to receiving the indication that the frequency anomaly event has occurred, the processor is also configured to determine, for at least one of the energy resource and the deferrable load, based on the frequency value, the nominal frequency value, and a power value of the electrical network, a respective power command, and cause at least one of the at least one energy resource and the at least one deferrable load to modify operation based on the respective power command.

42 ENGINEERING↗

Priority-enabled Load Balancing for Dispersed Computing

Opportunistic managed access to local in-network compute resources can improve the performance of distributed applications and reduce the dependence on shared network resources. Instead of backhauling application data to a centralized cloud data center for processing, networked services may be adaptively and continuously dispersed into shared compute resources that are closer to the source of need. While this approach has several benefits, support for mission-aware access to computation is often an afterthought, and is implemented as a brittle extension over traditional load-balancer solutions.In this work, we investigate the design of two priority-aware resource allocation strategies and two load-balancing dispatching strategies as first class citizens in an open-source dispersed computing middleware. We present a control theoretic analysis of these load-balancing primitives to identify weaknesses and strengths in our design, and recommend future directions. In parallel, we prototype two priority-aware allocation algorithms to validate our priority predictions. In initial experiments our prototype shows substantial gains in processing prioritized load. Finally, we make our source-code and experimental configurations open source.

Paulos, Aaron↗

Occupancy-Driven Stochastic Decision Framework for Ranking Commercial Building Loads

For effective integration of building operations into the evolving demand response programs of the power grid, real-time decisions concerning the use of building appliances for grid services must excel on multiple criteria, ranging from the added value to occupants' comfort to the quality of the grid services. In this paper, we present a data-driven stochastic decision-support framework to dynamically rank load control alternatives in a commercial building, addressing the needs of multiple decision criteria (e.g. occupant comfort, grid service quality) under uncertainties in occupancy patterns. We adopt a stochastic multi-criteria decision algorithm recently applied to prioritize residential on/off loads, and extend it to i) consider complex load control decisions (e.g. dimming of lights, changing zone temperature set-points) in a commercial building; and ii) systematically integrate zonal occupancy patterns to better identify short-term (and time-varying) opportunities for grid service participation. We evaluate the performance of the proposed framework for curtailment of air-conditioning, lighting, and plug-loads in a multi-zone commercial office building for a range of design choices. With the help of a prototype system that integrates an interactive \textit{Data Analytics and Visualization} frontend we demonstrate a way for the building operators to monitor and change in real-time the available flexibility in energy consumption and to develop trust in the decision recommendations by interpreting the rationale behind the ranking.

Jain, Milan↗

Multispectral impedance determination under dynamic load conditions

Impedance testing devices, circuits, systems, and related methods are disclosed. A Device Under Test (DUT) is excited with a multispectral excitation signal for an excitation time period while the DUT is under a load condition from a load operably coupled to the DUT. A response of the DUT is sampled over a sample time period. The sample time period is configured such that it includes an in-band interval during the excitation time period and one or more out-of-band intervals outside of the in-band interval. A response of the DUT to the load condition during the in-band interval is estimated by analyzing samples of the response from the one or more out-of-band intervals. Adjusted samples are computed by subtracting the estimated load response during the in-band interval from the samples from the in-band interval. An impedance of the DUT is estimated by analyzing the adjusted samples.

Christophersen, Jon P.↗

Solving Unit Commitment Problems with Demand Responsive Loads: Preprint

This paper focuses on using variations of the Frank-Wolfe algorithm for solving unit commitment problems with high volumes of demand responsive loads on the power grid. We present a formulation of the unit commitment problem with demand responsive loads. We then show through reformulation and relaxations of the problem that variations of the Frank-Wolfe algorithm can be used to determine the time series decisions for the demand responsive loads. We show through computational experiments on the RTS-GMLC test system that the time series of demand responsive load decisions obtained through our approach are near optimal and provide details regarding how large scale parallel implementations of our approach can be highly computationally efficient.

demand response↗

Coordinated net-load management

A management device includes at least one processor communicatively coupled to at least one energy resource controller controlling at least one energy resource and to at least one deferrable load controller controlling power to at least one deferrable load. The is configured to receive an indication, determined based on a frequency value of an electrical network and a nominal frequency value, that a frequency anomaly event has occurred. Responsive to receiving the indication that the frequency anomaly event has occurred, the processor is also configured to determine, for at least one of the energy resource and the deferrable load, based on the frequency value, the nominal frequency value, and a power value of the electrical network, a respective power command, and cause at least one of the at least one energy resource and the at least one deferrable load to modify operation based on the respective power command.

Lundstrom, Blake Richard↗

Distributed Energy Resource-Cognizant Upgrade Paths to the Traditional Restoration Strategy of Utilities for Improved Load Restoration: Preprint

Climate change has resulted in increasingly impactful and more frequent occurrences of extreme weather events. This trend poses a significant challenge for distribution utilities and system operators to ensure that there is uninterrupted power supply to critical loads in their networks under fault scenarios; however, currently, utilities deploying the automated fault location, isolation and restoration (FLISR) function in their advanced distribution management system (ADMS) do not take into account the available generation and load-modification capabilities of distributed energy resources present in the disconnected network due to an upstream isolated fault. This results in the network reconfiguration and restoration to result in sub-optimal load restoration. Therefore, this paper presents two approaches that can upgrade the existing FLISR capabilities of distribution utilities to significantly increase the restoration of critical loads. The performance of the proposed approaches is evaluated on a numerical model of a real distribution feeder in Georgia, USA.

DER↗

Forming Complex Nuclear Fuel Shapes in High-Loaded Silicide Surrogates

This work provides proof of the concept that high silicide loading nuclear fuel meat surrogates with complicated geometries can be produced with uniform density through an application of cold isostatic pressing (CIP). Dispersion fuels with high volumetric loading of U_3 Si_2 have challenges in fabrication. Fabrication involves a series of processes including powder compaction, rolling pack assembly, and roll forming. PNNL has undertaken extensive experimental work using MoSi2 and WSi2 as surrogates for U3Si2 to explore the feasibility of reducing or eliminating the issues through the application of CIP in the powder pressing step prior to rolling pack assembly. The composites were prepared at >40 vol% silicide loading, which was representative of 4.8 gU/cm^3 and formed via CIP at 50 KSI (Kilopound per Square Inch) pressure. The CIP mold design was taken through a design process which aimed to reduce defects and increase precision. The application of CIP here provides a broad strategy for producing highly loaded dispersion fuels with complex geometries and uniform density.

Clelland, Dustin T.↗

Preliminary Evaluation of Loading DOE Standard Canisters in the INL CPP-603 Irradiated Fuel Storage Facility - 20543

This paper looks at the equipment and operations necessary to load United States Department of Energy (DOE)-owned Spent Nuclear Fuel (SNF) into DOE Standard Canisters in the CPP-603 Irradiated Fuel Storage Facility (IFSF) in the Idaho Nuclear Technology and Engineering Center (INTEC) area at Idaho National Laboratory (INL). Two types of fuels are looked at in this evaluation: Advanced Test Reactor (ATR) fuel (uranium-aluminide fuel with aluminum cladding) and Peach Bottom fuel (thorium-uranium carbide fuel in a graphite matrix). The fuel ready for loading would come from fuel storage canisters in the CPP-603 facility. The paper describes the facility, the fuel types, the DOE Standard Canisters, and existing equipment; lists the needed loading operations; reviews facility features and equipment to perform the operations; and then lists the decisions, analyses, designs, demonstrations, and modifications that will be needed to perform the loading of DOE-owned SNF into DOE Standard Canisters in the CPP-603 IFSF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Comparison of As-loaded Dose Calculations to Measured Dose Rates

Demonstrating that the radiation dose fields surrounding spent nuclear fuel (SNF) storage and transportation systems meet the applicable limits set forth in 10 CFR 72 for storage and 10 CFR 71 for transportation is essential for the safe handling of radioactive material. The Used Nuclear Fuel-Storage, Transportation, and Disposal Analysis Resource and Data System (UNF-ST&DARDS) [2] is used to provide realistic estimates of SNF-related safety margins. The UNF-ST&DARDS dose rate analysis approach differs from that used in typical licensing approaches, which use design-basis assemblies with bounding source term characteristics to demonstrate the packaging design complies with the regulations. These bounding licensing approaches can increase the time needed to qualify fuel for loading into dry storage and the time a loaded system must wait prior to transportation. UNF-ST&DARDS dose rate assessments allow quantification of realistic, uncredited safety margins associated with actual fuel loading compared with the regulatory limits. While realistic estimation of the dose field surrounding SNF systems may allow for additional flexibility in operations, it is essential to understand how these predictions compare to measured doses. The U.S. Department of Energy Office of Integrated Waste Management and the Prairie Island Indian Community conducted a transportation dose assessment to estimate the site-specific incident-free radiation doses from shipping SNF by rail from the Prairie Island Nuclear Generating Plant (PINGP) through the Prairie Island Indian Community Reservation and Trust Land [5,6]. For that effort, the dose rates were obtained for 50 TN-40 and TN-40HT systems in storage configurations. This work compares the predicted dose rates from UNF-ST&DARDS as-loaded calculations with dose rates measured from 50 SNF storage systems at PINGP. The remainder of this paper discusses the data obtained for the evaluation, the modeling methods, and the results of the calculations.

spent nuclear fuel (SNF), UNF-ST&DARDS, Validation↗

Off-Design Load Analysis of sCO2 Bottoming Cycle for a Natural Gas Combined Cycle Power Plant with Carbon Capture

This work starts with the optimal design from Pidaparti et. al (2024) to analyze the off-design performance of the power plant from 100% down to 50% load. The main operational findings and plant-efficiency for off-load conditions while maintaining the target CO2 capture rate are presented. The goal of the work is to determine if there is a relative advantage or disadvantage for the sCO2 bottoming cycle compared to the steam bottoming cycle in terms of reduced load efficiency performance for the NGCC with carbon capture. Results show nearly identical efficiency profiles for the two cases from 100% to 50% load.

Chinen, Anderson Soares↗