Integrated Liquid Bismuth Propellant Feed System

A prototype bismuth propellant feed and control system was constructed and tested. An electromagnetic pump was used in this system to provide fine control of the hydrostatic pressure, and a new type of in-line flow sensor was developed to provide an accurate, real-time measurement of the mass flow rate. High-temperature material compatibility was a driving design requirement for the pump and flow sensor, leading to the selection of macor for the main body of both components. Post-test inspections of both components revealed no cracks or leaking in either. In separate proof-of-concept experiments, the pump produced a linear pressure rise as a function of current that compared favorably with theoretical pump pressure predictions, with a pressure of 10 kPa at 30 A. Flow sensing was successfully demonstrated in a bench-top test using gallium as a substitute liquid metal. A real-time controller was successfully used to control the entire system, simultaneously monitoring all power supplies and performing data acquisition duties.

Polzin, Kurt A.↗

Silver plating technique seals leaks in thin wall tubing joints

Leaks in thin wall tubing joints are sealed by cleaning and silver plating the hot gas side of the joint in the leakage area. The pressure differential across the silver during hydrostatic test and subsequent use forces the ductile silver into the leak area and seals it.

Blenderman, W. H.↗

Lifetime extension drop-test of real-world corroded 5 Quart Hagan nuclear material storage container

A 5Qt Hagan container with a 20-year history of nuclear material storage was challenged with three successive drop tests at a height of 3.7 meters. The total mass of the test package was 12.1 kg. The 1st and 2nd drop tests (center of gravity over the container bottom corner but 180 degrees apart on the container bottom face) passed the pre- and post- impact helium leak criterion at less than 1.00E-6 atm-cc/sec (ambient cubic centimeters per second). The 3rd and final test (center of gravity over top corner) failed with a post-impact gross leak of 1.1E-1 atmcc/sec. The RRFMC (Respirable Release Fraction Measurement Chamber) is a drop tower test system that is critical for the sustainability of the SAVY-4000™ series and Hagan-type (NFT Inc. Golden CO) nuclear material storage containers. These are the primary in-use nuclear material storage container types at the Los Alamos National Laboratory TA-55 facility. Results are presented to expand the technical knowledge basis for container lifetime, regarding actual exposure to corrosive gas species on the container inner surfaces. The primary source of general corrosion throughout the container is gaseous hydrogen chloride (HCl). This gas is generated by the degradation of the polyvinylchloride (PVC) bag-out bag. Additionally, in most cases, the nuclear material itself also releases HCl gas (due to residual chemical components associated with the material formation). The RRFMC drop tower gives the end-user the ability record and analyze high-speed video and photography and if needed aerosol mass release measurements. In this report the principal issue is the physical deformation of the 5Qt Hagan container. There were no mass release experiments of test aerosol mass in the present study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Smartphone application for visualizing building air leakage

Annually, unwanted air leakage through building envelopes accounts for 4 quads of energy consumption in the United States, which translates to about 10% of total building energy consumption. Locating and sealing leakage sites is crucial fordecreasing building energy consumption. Smartphones are ubiquitous and contain sophisticated cameras and highperformance processors that could be employed to visualize air leakage using the background-oriented schlieren imaging technique, making leak detection cheaper and easier. This technique requires a textured and high-contrast background such as a brick or concrete masonry unit wall, a building air leak that has a temperature difference compared with the ambient air, and an imaging system. This work focuses on using smartphones as the imaging system to visualize air leakages. The paper discusses application development and the results of testing to determine leakage visualization performance as a function of leak temperature. The results show that leaks with a temperature difference greater than 16°C compared with the ambient air temperature were visualized using existing smartphones.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)↗

H-Canyon Jumper Gasket Sealing Evaluation

H-Canyon Documented Safety Analysis approved December 2019 credits the leak integrity of HCanyon (HCA) process tanks, piping, and jumpers in preventing the release of radioactive material in a post seismic environment. Demonstration of leak tightness capability for this equipment was achieved through substantial analytical effort. However, one potential weak point that affects leak integrity exists at the gasketed joint between Hanford Connectors (HC) and nozzles. Review of the HCA Crane Log over a three-year period indicates the HCs periodically leak. Savannah River National Laboratory (SRNL) was requested to perform gasket compression tests that evaluate gasket relaxation characteristics, i.e., creep, and provide improvements to the HC installation process that can reduce or eliminate the frequency of leaks at HCs. A HC torque value of 312 ft-lbf is the target value used because it is the minimum torque value, with 95% confidence, when an unlubricated HC is impacted for standard sealing period of 9 seconds.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study to develop improved methods to detect leakage in fluid systems, phase 3

Research was undertaken to design and fabricate a prototype flight weight ultrasonic contact sensor leak detection system and to perform the necessary testing to collect enough data to establish design parameters and develop necessary baseline operating characteristics. The prototype system consists of five channels and is capable for monitoring frequencies from 1 KHz to 110 KHz.

Janus, J. C.↗

Electrical heating tests of uranium dioxide external fuel configuration at emitter temperature of 1900 K

Testing of two fuel clad specimens for thermionic reactor application is described. The annular UO2 fuel was clad on both sides with tungsten; heat rejection was radially inward. The tests were intended to study inner clad stability, fuel redistribution, and fuel melting problems. The specimens were tested in a vacuum chamber using electron bombardment heating. Fuel structural changes were studied using periodic gammagraphs and posttest metallography. The first specimen test was terminated at 50 hours because of a braze failure. The second specimen was tested for 240 hours when an outer clad leak developed due to a tungsten-water reaction. The fuel developed numerous cracks on cooldown but the inner clad remained dimensionally stable. The fuel cover gas did not impede the rate of fuel redistribution. Posttest examination showed the fuel had not melted during operation.

Diianni, D. C.↗

Post-test examination of a pool boiler receiver

A subscale pool boiler test apparatus to evaluate boiling stability developed a leak after being operated with boiling NaK for 791.4 hr at temperatures from 700 to 750 C. The boiler was constructed using Inconel 625 with a type 304L stainless steel wick for the boiler and type 316 stainless steel for the condenser. The boiler assembly was metallurgically evaluated to determine the cause of the leak and to assess the effects of the NaK on the materials. It was found that the leak was caused by insufficient (about 30 pct.) joint penetration in a butt joint. There was no general corrosion of the construction materials, but the room temperature ductility of the Inconel 625 was only about 6.5 pct. A crack in the heat affected zone of the Inconel 625 near the Inconel 625 to type 316 stainless steel butt joint was probably caused by excessive heat input. The crack was observed to have a zone depleted of iron at the crack surface and porosity below that zone. The mechanism of the iron depletion was not conclusively determined.

Dreshfield, Robert L.↗

A prototype closed aquaculture system for controlled ecological life support applications

Aquaculture has been proposed as a possible component of a life support system for extended duration space exploration. Atmospheric and hydrologic closure of an aquaculture system are necessary for this application and information on mass flows through such a system is important to integrating it as part of life support. A closed aquaculture system has been constructed and an extensive computer monitoring and control system and sampling protocol developed to provide this information. Preliminary tests indicate that the system has a negligible leak rate and can provide oxygen and carbon dioxide mass flow information.

Dreschel, T. W.↗

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Loop Heat Pipe↗

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Thermal Modeling↗

Experiments with phase change thermal energy storage canisters for Space Station Freedom

The solar dynamic power module proposed for the Space Station Freedom (SSF) uses the heat of fusion of a phase change material (PCM) to efficiently store thermal energy for use during eclipse periods. The PCM, a LiF-20CaF2 salt, is contained in annular, metal canisters located in a heat receiver at the focus of a solar concentrator. PCM canister ground-based experiments and analytical heat transfer studies are discussed. The hardware, test procedures, and test results from these experiments are discussed. After more than 900 simulated SSF orbital cycles, no canister cracks or leaks were observed and all data were successfully collected. The effect of 1-g test orientation on canister wall temperatures was generally small while void position was strongly dependent on test orientation and canister cooling. In one test orientation, alternating wall temperature data were measured that supports an earlier theory of oscillating vortex flow in the PCM melt. Analytical canister wall temperatures compared very favorably with experimental temperature data. This illustrates that ground-based canister thermal performance can be predicted well by analyses that employ straight-forward, engineering models of void behavior and liquid PCM free convection.

Kerslake, Thomas W.↗

Test program, helium II orbital resupply coupling

The full scope of this program was to have included development tests, design and production of custom test equipment and acceptance and qualification testing of prototype and protoflight coupling hardware. This program was performed by Ball Aerospace Systems Division, Boulder, Colorado until its premature termination in May 1991. Development tests were performed on cryogenic face seals and flow control devices at superfluid helium (He II) conditions. Special equipment was developed to allow quantified leak detection at large leak rates up to 8.4 x 10(exp -4) SCCS. Two major fixtures were developed and characterized: The Cryogenic Test Fixture (CTF) and the Thermal Mismatch Fixture (Glovebox). The CTF allows the coupling hardware to be filled with liquid nitrogen (LN2), liquid helium (LHe) or sub-cooled liquid helium when hardware flow control valves are either open or closed. Heat leak measurements, internal and external helium leakage measurements, cryogenic proof pressure tests and external load applications are performed in this fixture. Special reusable MLI closures were developed to provide repeatable installations in the CTF. The Thermal Mismatch Fixture allows all design configurations of coupling hardware to be engaged and disengaged while measuring applied forces and torques. Any two hardware components may be individually thermally preconditioned within the range of 117 deg K to 350 deg K prior to engage/disengage cycling. This verifies dimensional compatibility and operation when thermally mismatched. A clean, dry GN2 atmosphere is maintained in the fixture at all times. The first shipset of hardware was received, inspected and cycled at room temperature just prior to program termination.

Hyatt, William S.↗

Using Decision Trees to Detect and Isolate Simulated Leaks in the J-2X Rocket Engine

The goal of this work was to use data-driven methods to automatically detect and isolate faults in the J-2X rocket engine. It was decided to use decision trees, since they tend to be easier to interpret than other data-driven methods. The decision tree algorithm automatically "learns" a decision tree by performing a search through the space of possible decision trees to find one that fits the training data. The particular decision tree algorithm used is known as C4.5. Simulated J-2X data from a high-fidelity simulator developed at Pratt & Whitney Rocketdyne and known as the Detailed Real-Time Model (DRTM) was used to "train" and test the decision tree. Fifty-six DRTM simulations were performed for this purpose, with different leak sizes, different leak locations, and different times of leak onset. To make the simulations as realistic as possible, they included simulated sensor noise, and included a gradual degradation in both fuel and oxidizer turbine efficiency. A decision tree was trained using 11 of these simulations, and tested using the remaining 45 simulations. In the training phase, the C4.5 algorithm was provided with labeled examples of data from nominal operation and data including leaks in each leak location. From the data, it "learned" a decision tree that can classify unseen data as having no leak or having a leak in one of the five leak locations. In the test phase, the decision tree produced very low false alarm rates and low missed detection rates on the unseen data. It had very good fault isolation rates for three of the five simulated leak locations, but it tended to confuse the remaining two locations, perhaps because a large leak at one of these two locations can look very similar to a small leak at the other location.

Schwabacher, Mark A.↗

Capillary Limit of a Miniature Loop Heat Pipe with Multiple Evaporators and Multiple Condensers

An experimental investigation of a miniature loop heat pipe with multiple evaporators and multiple condensers were conducted in order to evaluate its capillary limit. The experimental tests were conducted by varying heat load to one or both evaporators, with and without active temperature control of compensation chamber (CC) using the thermoelectric devices, and variable tilts between the evaporators and the CCs. The physical process of the loop and thermal conductance of the heat leak from evaporator to (CC) were discussed based on the test results. The difference of the temperature profiles between with and without active control of CC temperature was evaluated. The effect of the gravity on capillary limit and CC temperature was also evaluated by comparing the test result in horizontal position with that in vertical position. The loop recovery after capillary limit was exceeded was also described.

Ku, Jentung↗