Search NASA⌕ Search

SEARCH · Search NASA

Results for “Life Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Optical communication for space missions

Activities performed at NASA/GSFC (Goddard Space Flight Center) related to direct detection optical communications for space applications are discussed. The following subject areas are covered: (1) requirements for optical communication systems (data rates and channel quality; spatial acquisition; fine tracking and pointing; and transmit point-ahead correction); (2) component testing and development (laser diodes performance characterization and life testing; and laser diode power combining); (3) system development and simulations (The GSFC pointing, acquisition and tracking system; hardware description; preliminary performance analysis; and high data rate transmitter/receiver systems); and (4) proposed flight demonstration of optical communications.

Firtmaurice, M.↗

Extended Life PZT Stack Test Fixture

Piezoelectric stacks are being sought to be used as actuators for precision positioning and deployment of mechanisms in future planetary missions. Beside the requirement for very high operation reliability, these actuators are required for operation at space environments that are considered harsh compared to normal terrestrial conditions.These environmental conditions include low and high temperatures and vacuum or high pressure. Additionally, the stacks are subjected to high stress and in some applications need to operate with a very long lifetime durability.Many of these requirements are beyond the current industry design margins for nominal terrestrial applications. In order to investigate some of the properties that will indicate the durability of such actuators and their limitations we have developed a new type of test fixture that can be easily integrated in various test chambers for simulating environmental conditions, can provide access for multiple measurements while being exposed to adjustable stress levels. We designed and built two test fixtures and these fixtures were made to be adjustable for testing stacks with different dimensions and can be easily used in small or large numbers. The properties that were measured using these fixtures include impedance, capacitance, dielectric loss factor, leakage current, displacement, breakdown voltage, and lifetime performance. The fixtures characteristics and the test capabilities are presented in this paper.

test fixtures↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 1

Washington River Protection Solutions (WRPS) conducted tests of four types of chemical cartridges for air-purifying respirators (APR) and powered air-purifying respirators (PAPR) to determine the period of time the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the Hanford AX tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing a cartridge service life. Testing is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing using vapors from a Hanford AX tank farm exhauster slipstream was conducted from August 25–27, 2017. Vapors from the exhauster slipstream were fed to two respirator cartridge test stands developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Four different cartridges were assessed. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using an APR cartridge test stand. Multipurpose PAPR cartridges—MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR57 (TL2) (3M Company, Maplewood, Minnesota)—also were tested over the same two days using a separate PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mercury bombardment ion thrusters - Development status, performance levels, and test history

The present work describes the development status, performance levels, and life test history of 5-cm, 8-cm, and 30-cm mercury bombardment ion thrusters and their respective power processors. A 2.6 kW, 30-cm thruster module and its power processor unit are now available that established the performance required by interplanetary and geosynchronous orbit raising missions. An 8-cm thruster with nominal 4.5 mN thrust level capability has demonstrated a high performance over a wide range of thrust and operational life.

Molitor, J. H.↗

Fabrication and testing of sealed silver-zinc cells

A number of Type HS40-7 sealed silver-zinc cells and experimental 40AH sealed silver-zinc cells were fabricated. Cells of each experimental group contained one variation from the standard configuration (HS40-7) cell. Cells from each of five experimental cell groups and cells of the standard configuration were tested to characterize voltage and capacity performance at various discharge rates. The test cells were then subjected to 100 percent DOD Cycle Life Testing at 22 C. Results indicate that material and/or process variations are available which will improve both performance and cycle life of the existing 40 ampere-hour sealed silver-zinc cell configurations. The average cycle life to 50 percent loss of nominal capacity in cells from two (2) of the experimental groups was 150 - 165 cycles. A series of 12 ampere-hour cells was fabricated and tested as part of a program to incorporate the 40AH sealed silver-zinc cell fabrication technology into a cell of smaller size. Base-line configuration cells and experimental variations were produced using the HS40-7 cell fabrication and processing methods adapted to the smaller cell size.

Donnel, C. P., III↗

Space Station Solar Array Joint Repair

In Oct 2007 the International Space Station (ISS) crew noticed a vibrating camera in the vicinity of Starboard Solar Alpha Rotary Joint (SARJ). It had less than 5 months of run time when the anomaly was observed. This approximately 3.2 meter diameter bearing joint supports solar arrays that power the station critical to its operation. The crew performed an EVA to identify what was causing the vibration. It was discovered that one of the 3 bearing tracks of this unconventional bearing had significant spalling damage. This paper discusses the SARJ's unique bearing design and the vulnerability in its design leading to the observed anomaly. The design of a SARJ vacuum test rig is also described along with the results of a life test that validated the proposed repair should extend the life of the SARJ a minimum of 18 years on-orbit.

Loewenthal, Stuart↗

Reliability of High-Voltage Tantalum Capacitors. Parts 3 and 4)

Weibull grading test is a powerful technique that allows selection and reliability rating of solid tantalum capacitors for military and space applications. However, inaccuracies in the existing method and non-adequate acceleration factors can result in significant, up to three orders of magnitude, errors in the calculated failure rate of capacitors. This paper analyzes deficiencies of the existing technique and recommends more accurate method of calculations. A physical model presenting failures of tantalum capacitors as time-dependent-dielectric-breakdown is used to determine voltage and temperature acceleration factors and select adequate Weibull grading test conditions. This model is verified by highly accelerated life testing (HALT) at different temperature and voltage conditions for three types of solid chip tantalum capacitors. It is shown that parameters of the model and acceleration factors can be calculated using a general log-linear relationship for the characteristic life with two stress levels.

Teverovsky, Alexander↗

Analysis of Weibull Grading Test for Solid Tantalum Capacitors

Weibull grading test is a powerful technique that allows selection and reliability rating of solid tantalum capacitors for military and space applications. However, inaccuracies in the existing method and non-adequate acceleration factors can result in significant, up to three orders of magnitude, errors in the calculated failure rate of capacitors. This paper analyzes deficiencies of the existing technique and recommends more accurate method of calculations. A physical model presenting failures of tantalum capacitors as time-dependent-dielectric-breakdown is used to determine voltage and temperature acceleration factors and select adequate Weibull grading test conditions. This, model is verified by highly accelerated life testing (HALT) at different temperature and voltage conditions for three types of solid chip tantalum capacitors. It is shown that parameters of the model and acceleration factors can be calculated using a general log-linear relationship for the characteristic life with two stress levels.

Teverovsky, Alexander↗

Reliability and Qualification of Hardware to Enhance the Mission Assurance of JPL/NASA Projects

Packaging Qualification and Verification (PQV) and life testing of advanced electronic packaging, mechanical assemblies (motors/actuators), and interconnect technologies (flip-chip), platinum temperature thermometer attachment processes, and various other types of hardware for Mars Exploration Rover (MER)/Mars Science Laboratory (MSL), and JUNO flight projects was performed to enhance the mission assurance. The qualification of hardware under extreme cold to hot temperatures was performed with reference to various project requirements. The flight like packages, assemblies, test coupons, and subassemblies were selected for the study to survive three times the total number of expected temperature cycles resulting from all environmental and operational exposures occurring over the life of the flight hardware including all relevant manufacturing, ground operations, and mission phases. Qualification/life testing was performed by subjecting flight-like qualification hardware to the environmental temperature extremes and assessing any structural failures, mechanical failures or degradation in electrical performance due to either overstress or thermal cycle fatigue. Experimental flight qualification test results will be described in this presentation.

PRTs↗

A 7700 hour endurance test of a 30-cm Kaufman thruster

This paper describes an ongoing endurance test of the ion thruster which is expected to form the basis of future prime propulsion systems. The purpose of the test is to demonstrate the lifetime capability of such critical components as cathodes, vaporizers, isolators, and optics. The endurance test was preceded by development of an ion engine life test system and several intermediate duration tests. The elements of the test system are briefly described and the thruster modifications which resulted from the intermediate tests are evaluated in terms of the endurance test results. Thruster performance during the endurance test is described as well as the conclusions that can be drawn from the 8600 hours that have been completed as of March 6, 1975.

Collett, C. R.↗

In Flight Performance of a Six Ampere-hour Nickel-cadmium Battery in Low Earth Orbit

Flight data for 17,000 orbital cycles are reviewed and summarized. The nickel cadmium battery system operated without failure or abnormality. Battery trend analysis used in determining the feasibility of extending mission life is discussed. The life test data for 20% depth of discharge indicates design life requirements would be reached even at a deeper depth of discharge.

Mcdermott, J. K.↗

Endurance tests with large-bore tapered-roller bearings to 2.2 million DN

Endurance life tests were run with standard-design bearings of vacuum-melted AISI 4320 and CBS-1000M at 12,500 rpm, and high-speed bearings of CBS-1000M and trough-hardened AISI M-50 at 18,500 rpm. Both sets of bearings were of 120.65 mm bore-tapered roller type, and were run under heavy combined radial and thrust loads until either fatigue failure or a preset cutoff time of 1100 hours was reached. It was found that: (1) the CBS-1000M standard-design bearings ran to a 10% life approximately six times that of the rated catalog life; (2) twelve identical bearings of AISI 4320 ran to ten times rated catalog life without failure; (3) cracking and fracture of the cones of AISI M-50 high-speed design bearings occurred at 18,500 rpm due to high tensile hoop stresses; and (4) four CBS 1000M high-speed bearings ran to twenty-four times rated catalog life without spalling, cracking or fracture failures.

Parker, R. J.↗

Endurance tests with large-bore tapered-roller bearings to 2.2 million DN

Endurance life tests were run with standard design and optimized high-speed design 120.65-mm-(4.750-in.-) bore tapered-roller bearings at shaft speeds of 12,500 and 18,500 rpm, respectively. Standard design bearings of vacuum melted AISI 4320 and CBS-1000M, and high-speed design bearings of CBS-1000M and through-hardened AISI M-50 were run under heavy combined radial and thrust load until fatigue failure or until a preset cutoff time of 1100 hours was reached. Standard design bearings made from CBS 1000M material ran to a 10 percent life approximately six times rated catalog life. Twelve identical bearings of AISI 4320 material ran to ten times rated catalog life without failure. Cracking and fracture of the cones of AISI M-50 high-speed design bearings occurred at 18,500 rpm due to high tensile hoop stresses. Four CBS 1000M high-speed design bearings ran to twenty-four times rated catalog life without any spalling, cracking or fracture failures.

Parker, R. J.↗

Fuel cell technology program

A fuel cell technology program was established to advance the state-of-the art of hydrogen oxygen fuel cells using low temperature, potassium hydroxide electrolyte technology as the base. Cell and component testing confirmed that low temperature, potassium hydroxide electrolyte technology is compatible with the requirements of the space shuttle Phase B contractors. Testing of the DM-1 powerplant demonstrated all of the important requirements of the shuttle except operating life. Testing also identified DM-1 powerplant life limiting mechanisms; hydrogen pump gear wear and pressurization of the cell stack over its design limits.

Source record↗

Thrust vectoring of broad ion beams for spacecraft attitude control

Thrust vectoring is shown to increase the attractiveness of ion thrusters for satellite control applications. Incorporating beam deflection into ion thrusters makes it possible to achieve attitude control without adding any thrusters. Two beam vectoring systems are described that can provide up to 10-deg beam deflection in any azimuth. Both systems have been subjected to extended life tests on a 5-cm thruster which resulted in projected life times of from 7500 to 20,000 hours.

Collett, C. R.↗

Design principles of a rotating medium speed mechanism

Design principles of a medium speed mechanism (MSM) are presented, including discussion on the relative merits of beryllium and aluminium as structural materials. Rotating at a speed of 60 rpm, the application envisaged for the MSM was as a despin bearing for the despun platform or despun antenna of a spin stabilized satellite. The MSM was built and tested to qualification level and is currently undergoing real time life testing.

Hostenkamp, R. G.↗